expectations vs achievements - quality control of blood components

75
Sitalakshmi S Professor and Head Department of Clinical Pathology St John’s Medical College, Bangalore Expectations Vs Achievements - Quality Control Of Blood Components

Upload: teddy

Post on 23-Feb-2016

58 views

Category:

Documents


0 download

DESCRIPTION

Expectations Vs Achievements - Quality Control Of Blood Components. Sitalakshmi S Professor and Head Department of Clinical P athology St John’s Medical College, Bangalore. The Case……. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Expectations  Vs  Achievements - Quality Control Of Blood Components

Sitalakshmi S

Professor and Head

Department of Clinical Pathology

St John’s Medical College, Bangalore

Expectations Vs Achievements - Quality Control Of Blood

Components

Page 2: Expectations  Vs  Achievements - Quality Control Of Blood Components

THE CASE…….• A 65-year old lady, was referred to the Medical

College Hospital for recent onset fatigue and weight loss .

• A CBC showed a WBC count 55,000/ul with 90 % peroxidase positive blasts, normochromic normocytic anemia (Hgb 8 g/dl) and thrombocytopenia (40,000/ul).

Page 3: Expectations  Vs  Achievements - Quality Control Of Blood Components

• On physical exam, the patient was afebrile, normotensive

• There were no bleeding manifestations• An admission ECG and history are negative for

cardiovascular disease

Page 4: Expectations  Vs  Achievements - Quality Control Of Blood Components

NEED FOR TRANSFUSION?• Does the patient require transfusion of:

packed red blood cells? platelets?

• Although the patient is mildly anemic and thrombocytopenic, she does not fulfill criteria for transfusion at this time.

• Her Hgb > 7g/dl with no history of cardiovascular disease or symptomatic anemia (other than fatigue).

Page 5: Expectations  Vs  Achievements - Quality Control Of Blood Components

• If the patient had a history of cardiovascular illness or signs or symptoms of significant anemia, it would be appropriate to maintain her Hct at a higher baseline.

• Similarly, the patients platelet count (40,000/ul ) with no bleeding manifestations does not require prophylactic platelet transfusion

Page 6: Expectations  Vs  Achievements - Quality Control Of Blood Components

FURTHER CLINICAL COURSE….• Eight days after admission for induction

chemotherapy, the patient's CBC shows:WBC 500/ul Hgb 6.9g/dl Platelet 8,000/ul

The patient's physician ordered 2 units leukoreduced and irradiated packed red blood cells and 6 units of pooled platelet concentrates (3 X 10¹¹ platelets total).

Was transfusion of PRBC and platelets appropriate in this patient at this time?

Page 7: Expectations  Vs  Achievements - Quality Control Of Blood Components

NEED FOR TRANSFUSION…..• Yes. The patient's hemoglobin < 7.0 g/dL in the

setting of a bone marrow failure • Likewise, the patient's platelet count has now

decreased to the point where she is at risk for spontaneous hemorrhage

Page 8: Expectations  Vs  Achievements - Quality Control Of Blood Components

• A CBC 1 hour after the administration of platelets and PRBC shows:Hgb 9.1g/dl Hct 27.3 % Platelets 30,000/ul

• Corrected count increment (CCI)(postTPC - preTPC) x (BSA in M²)/(TNPTx 10¹¹) where:

• TPC=transfusion platelet count

• BSA=body surface area

• TNPT=total number of platelets transfused

For this patient: post TPC 30,000 pre TPC 8,000 CCI=(30-8) x 1.5/3 = 11

Page 9: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Did the patient get an appropriate response from the

PRBC and platelet transfusions?

• Yes to both. The patient was transfused with 2 units of

packed red cells (PRBC), Hgb of 6.9g/dl rising to 9.1g/dl.

An average adult show a 1 g or 3% rise in Hct with each

unit of packed red cells.

• Likewise, the calculated CCI was 11.0. A CCI of > 7.0 is

considered a good clinical response.

Page 10: Expectations  Vs  Achievements - Quality Control Of Blood Components

What are the factors that affect the patient’s response to transfusion of blood components?

Page 11: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Quality of blood components transfused• Patient’s disease condition and patients

physiological response to transfusion

• How do we as transfusion specialists ensure quality of blood components?

• What is our role in patient transfusion therapy?

Page 12: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Quality programmes and systems in transfusion

medicine differ slightly from other disciplines of

laboratory medicine

• It takes two different forms.

• the blood supply system and

• Clinical transfusion therapy.

Page 13: Expectations  Vs  Achievements - Quality Control Of Blood Components

• The approach used to ensure highest quality in the blood supply system is similar to that used in the manufacture of pharmaceuticals

• The approach used to ensure that the patient receives highest quality of transfusion therapy is a part of hospital’s overall quality care program

Page 14: Expectations  Vs  Achievements - Quality Control Of Blood Components

• The measures taken for quality assurance in transfusion medicine are:

• Measures needed during the process of blood component preparation and storage

• Measures taken during the process of actual transfusion of the blood components. This aspect has more to do with good clinical transfusion practices

Page 15: Expectations  Vs  Achievements - Quality Control Of Blood Components

STANDARDS FOR QUALITY MONITORING• The wide variability of the source material

from which blood components are prepared makes it difficult to set stringent limits.

• Nevertheless, realistic minimum specifications should be set and complied with.

Page 16: Expectations  Vs  Achievements - Quality Control Of Blood Components

STANDARDS FOR QUALITY MONITORING The standards are based on minimum

requirements• On what is achievable using the most up-to-date

methods and systems

• Testing of random components to ensure they

achieve reliably minimum specific requirements

as per the standards

Page 17: Expectations  Vs  Achievements - Quality Control Of Blood Components

COMPONENT PREPARATION• The quality of the components is assured by

control of all stages of manufacture• donor selection • Blood collection• Component separation • labeling • Storage

Page 18: Expectations  Vs  Achievements - Quality Control Of Blood Components

• The starting materials for preparation of blood components are blood donations collected from suitable donors.

• Conditions of storage or transport• and the time prior to processing,• are contributing factors to the quality of the

product.

Page 19: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Delays in preparation

• unsuitable conditions of storage or transport

• may adversely affect the quality of the final product.

• Blood and blood components should be placed in controlled and validated conditions as soon as possible after collection.

Page 21: Expectations  Vs  Achievements - Quality Control Of Blood Components

SRANDARD OPERATING PROCEDURES• The standard operating procedures should

describe the specifications for materials that will influence the quality of the final blood component.

• Specifications should be in place for blood components (intermediate and final components), starting materials, additive solutions, blood collection bags and equipment.

Page 22: Expectations  Vs  Achievements - Quality Control Of Blood Components

BLOOD COLLECTION• The collection process itself is crucial for the

quality of blood components. • Measures such as a reliable arm-cleaning and

disinfection procedure, the use of closed and sterile collection systems should be implemented.

• Free flow of blood during collection is crucial• Time limits is defined for the processing of blood

components.

Page 23: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Each component should be visually inspected at each stage of processing and immediately prior to issue.

• The component must be withdrawn if there is evidence of leakage, damage to or fault in the container, excessive air, suspicion of microbial contamination or any other contraindications such as platelet clumping, unusual turbidity, haemolysis or other abnormal colour change.

Page 24: Expectations  Vs  Achievements - Quality Control Of Blood Components

Frequency of quality control

• Should be performed on • at least 1% of all components produced • for all parameters to be measured

• If fewer than 100, then at least 4 per month

• 75% or more of components monitored must meet the specifications

Page 25: Expectations  Vs  Achievements - Quality Control Of Blood Components

TRANSPORT• Donations and samples should be transported to the

processing site in accordance with procedures that ensure a constant approved temperature.

• This is especially important when blood is transported from distant collection sites.

• Portable temperature loggers may be used to record the temperature during the transportation of blood to the processing site.

Page 26: Expectations  Vs  Achievements - Quality Control Of Blood Components

COMPONENT WEIGHT: VOLUME

• To provide information, which is useful for clinicians, the component specifications generally require the component label to indicate a volume.

• whole blood volume is calculated by deducting the weight of the bag assembly and dividing the resulting weight by the specific gravity of 1.06

Page 27: Expectations  Vs  Achievements - Quality Control Of Blood Components

COMPONENT WEIGHT: VOLUME

• For red cell components, volume is calculated by weighing the pack, deducting the weight of the pack assembly only and dividing the resultant weight by the specific gravity 1.09

• For platelets and plasma components, volume is calculated by weighing the pack, deducting the weight of the pack assembly and dividing the resulting weight by the specific gravity of 1.03.

Page 28: Expectations  Vs  Achievements - Quality Control Of Blood Components
Page 29: Expectations  Vs  Achievements - Quality Control Of Blood Components

STANDARD OPERATING PROCEDURES

• The standard operating procedures for component preparation should be followed at all times using the validated methods.

• Any deviations from these established procedures and processes may result in products not meeting specifications and such products should be considered as non-conforming products and must not be released .

Page 30: Expectations  Vs  Achievements - Quality Control Of Blood Components

METHODS OF PRODUCTION

• Blood components may be prepared by using a centrifugation step with subsequent separation, or by apheresis technology during collection

• The use of closed systems is a must for all steps in component processing.

• Where sterile connecting devices are used to maintain a functionally closed system they should be correctly used in accordance with a validated procedure. The resulting weld should be checked for satisfactory alignment and integrity.

Page 31: Expectations  Vs  Achievements - Quality Control Of Blood Components

EQUIPMENT• Equipment used in collection, processing, testing and

storage of blood and blood component should be

observed, standardized and calibrated on a regularly

scheduled basis

• Procedures should be described in the Standard

Operating Procedure (SOP) Manual

Page 32: Expectations  Vs  Achievements - Quality Control Of Blood Components

EQUIPMENT PERFORMANCE MONITORING

Equipment Performance Frequency Frequency of Calibration

Blood mixer Observe wt. of first container of blood filled for correct results

Each day of use Standardize with container of known mass or volume before initial use and after repairs

Blood bag weighing scale

Standardize against container of known weight

Each day of use As often as necessary

Refrigerated centrifuge

Observe speed & temperature

Each day of use As often as necessary

Temperature recorder

Compare against thermometer

Daily As often as necessary

Water bath Observe temp. Each day of use As often as necessary

Page 33: Expectations  Vs  Achievements - Quality Control Of Blood Components

REFRIGERATED CENTRIFUGE

• Calibrated upon installation and repair

• Calibration of speed with tachometer twice a year

• Timer to be checked with tachometer

Page 34: Expectations  Vs  Achievements - Quality Control Of Blood Components

PLATELET AGITATOR

• Number of strokes 70+/- 10 per min• Periodic cleaning and lubrication

Page 35: Expectations  Vs  Achievements - Quality Control Of Blood Components

Quality Control of equipment for component storage

• Daily periodic temperature monitoring of refrigerators, freezers and platelet incubator

• Temperature check at different locations in large equipment

• Audio and visual alarms to alert• Continuous temperature recorder• Actual temperature checked with

Hg themometer in glycerol

Page 36: Expectations  Vs  Achievements - Quality Control Of Blood Components

CENTRIFUGATION• The centrifugation parameters (revolutions per minute,

temperature, time, acceleration, deceleration) are important for the composition and characteristics of the specific components.

• These critical parameters should be defined on the basis of validation data that demonstrate a process that consistently produces quality products.

• For each run, the centrifugation records should identify the operator and confirm that the centrifugation process was performed according to specifications.

Page 37: Expectations  Vs  Achievements - Quality Control Of Blood Components

SEPARATION• After centrifugation, the bag system should be carefully

removed from the centrifuge and placed into a plasma expressor or blood separation system.

• The different layers of the components (red cells, platelets, plasma) should be transferred to the satellite bags within the closed systems, in a manner designed to optimize the harvest of the intended component while minimizing the carry-over of other component fractions.

• Alternatively, blood components can be separated during collection by apheresis technology

Page 38: Expectations  Vs  Achievements - Quality Control Of Blood Components

PACKED RED CELL CONCENTRATE

• Red-cell concentrates are obtained from whole blood by centrifugation and removal of plasma with or without buffy coat, depending on the centrifugation parameters.

• The red cells should be stored at 2–6°C as soon as possible. Alternatively, red-cell concentrates may be obtained using an apheresis system and stored at 2–6°C.

Page 39: Expectations  Vs  Achievements - Quality Control Of Blood Components

LEUCOREDUCTION• To obtain leukocyte-reduced red-cell concentrates, either

whole blood filtration can be applied prior to separation or there can be a post-separation filtration of the red-cell concentrate..

• Red-cell concentrates are stored at 2 -8oC. The storage time depends on the anticoagulant/preservative solution used.

• The introduction of any leukocyte reduction process either by filtration or special centrifugation technique requires careful validation

Page 40: Expectations  Vs  Achievements - Quality Control Of Blood Components

LEUCOREDUCTION• Counting residual WBC by automated cell

counters may not be reliable for very low WBC count of < 100WBC /ul

• Nageotte counting chambers are reliable for as low as 1 WBC/ul

• Flow cytometer can detect as low as 0.1 WBC/ul

Page 41: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF RED CELL CONCENTRATEPARAMETER QUALITY REQUIRMENTS Frequency of testing

VOLUME 280+/-60 ML 1% of all units

HEMATOCRIT 0.70+/-0.05[ >70%] 1% of all units

Sterility Culture 1% of all units

Page 42: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Further methods of preparation, such as irradiation or washing, are applied to obtain specific red-cell products, depending on the clinical indication.

• Periodic quality control should be performed on the final product to ensure that the manufacturing process is consistent At a minimum, the following critical parameters should be checked during the quality control assays:

— volume

— haematocrit

— haemolysis at the end of storage

— residual leukocytes, if leukocyte reduction is performed.

Page 43: Expectations  Vs  Achievements - Quality Control Of Blood Components

FRESH FROZEN PLASMA

Page 44: Expectations  Vs  Achievements - Quality Control Of Blood Components

FREEZING OF PLASMA

• Freezing is an important processing step that has an impact on quality of plasma. The rate at which freezing proceeds and the core temperature are both important parameters.

• Freezing speed will be influenced by the the freezing equipment, loading pattern and the volume of plasma.

• Rapid plasma freezing prevents or reduces the loss of critical constituents such as Factor VIII in frozen plasma.

Page 45: Expectations  Vs  Achievements - Quality Control Of Blood Components

FRESH FROZEN PLASMA

• FFO is prepared either from whole blood or from plasma collected by apheresis, and is frozen within a defined period of time to a temperature that should adequately maintain the labile coagulation factors in a functional state.

• Factor VIII content is critical both as a quality indicator and to assure the efficacy of cryoprecipitate.

• If plasma is separated from a unit of whole blood that is refrigerated to 4°C, centrifugation should preferably take place within eight hours of collection

Page 46: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF FFPPARAMETER QUALITY REQUIRMENTS Frequency of testing

VOLUME 200-250 ML 4 units per month or 1%

STABLE COAGULATION FACTORS

200 UNITS 4 units per month or 1%

FACTORVIII 0.7 UNITS/ML 4 units per month or 1%

FIBRINOGEN 200-400 mg 4 units per month or 1%

Page 47: Expectations  Vs  Achievements - Quality Control Of Blood Components

PLATELET CONCENTRATE

Page 48: Expectations  Vs  Achievements - Quality Control Of Blood Components

PLATELET CONCENTRATES

• Platelet concentrates are derived from whole blood or are obtained by apheresis.

• After collection, whole blood can be kept at 20°C and 24°C,. for up to 4 – 6 hours

• The whole blood unit is centrifuged so that an optimal number of platelets remain in plasma (platelet-rich plasma, or PRP). Platelet concentrates are then obtained by hard-spin centrifugation of PRP and are then resuspended.

Page 49: Expectations  Vs  Achievements - Quality Control Of Blood Components

PLATELET CONCENTRATES

• if whole blood is centrifuged so that the blood platelets are primarily sedimented to the buffy coat layer, the buffy coat is separated and further processed to obtain a platelet concentrate.

• Either a single buffy coat or a pool of buffy coats is diluted with plasma, and platelets are concentrated by further centrifugation.

• The platelet content per unit depends on the method of preparation. Similarly, the residual leukocyte content will vary according to the centrifugation parameters

Page 50: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Platelet concentrates (both from whole blood and apheresis) should be stored in conditions that guarantee that viability and haemostatic activities are optimally preserved.

• The storage temperature should be 20–24°C.• Continuous gentle agitation of platelets during storage

should be sufficient to guarantee the availability of oxygen to the platelets (but should be as gentle as possible).

• A storage time should not exceed five days

Page 51: Expectations  Vs  Achievements - Quality Control Of Blood Components
Page 52: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF PLATELET CONCENTRATE (PREPARED FROM BUFFY COAT)

Parameter Quality requirement Frequency of control

Volume 70-90 ml 4 units / month

Platelet count > 6-9 x 1010 4 units / month

pH > 6.0 4 units / month

RBC contamination Traces to 0.5 ml 4 units / month

WBC contamination < 5.5 x 106 4 units / month

Page 53: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF PLATELET CONCENTRATE BY PRPPARAMETER QUALITY REQUIRMENTS Frequency of testing

VOLUME 50-70ML All units

PLATELET COUNT >3X10 10 / UNIT 4 units per month or 1% if > 100

PH >6 4 units per month or 1% if > 100

RBC CONTAMINATION <0.1X10 12/L 4 units per month or 1% if > 100

WBC CONTAMINATION <1.5X10 9/L 4 units per month or 1% if > 100

Page 54: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF PLATELET CONCENTRATE BY APHERESIS

PARAMETERS QUALITY REQUIRMENTS

VOLUME 200-500 ml

PLATELET COUNT >3.0X10 11/unit

PH >6

LEUCOCYTES < 0.03X10 9/L

RED CELLS TO 0.5ML

Page 55: Expectations  Vs  Achievements - Quality Control Of Blood Components

CALCULATION THE PLATELET COUNT PER BAG

• Weight of empty bag=24gm

• Volume =weight of plt bag—wt of empty bag

1.03

Eg:Wt OF PLT BAG=89

VOLUME=89-24=65gm,TO CONVERT TO mL

65 =63ml

1.03

Page 56: Expectations  Vs  Achievements - Quality Control Of Blood Components

• VOLUME=63ml

• PLT COUNT=NO.OF PLT/ulX1000XVOLUME

• PLT COUNT=10X1000X63

• ==6.3 X1010/L

Page 57: Expectations  Vs  Achievements - Quality Control Of Blood Components

CRYOPRECIPITATE

• Cryoprecipitate is the cryoglobulin fraction of

plasma and contains a major portion of the Factor

VIII, von Willebrand factor, fi brinogen, Factor XIII

and fibronectin present in plasma.

Page 58: Expectations  Vs  Achievements - Quality Control Of Blood Components

CRYOPRECIPITATE

• Plasma is allowed to thaw either overnight at 2–6°C or by a rapid-thaw technique.

• Following thawing, the supernatant cryo-poor plasma and the cryoprecipitate are separated by hard-spin centrifugation. The cryo-poor plasma is then expressed into a transfer bag. The two components are refrozen to the appropriate core temperature.

Page 59: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF CRYOPRECIPITATE

PARAMETER QUALITY REQUIRMENTSVOLUME 200-250 ML PLASMA

STABLE COAGULATION FACTORS 200 UNITS

FACTORVIII 0.7 UNITS/ML

FIBRINOGEN 150-250 mg

Page 60: Expectations  Vs  Achievements - Quality Control Of Blood Components

QC OF CRYOPRECIPITATE• FOR FACTOR VIII assay -TAKE 1/10 DILUTION

• [0.9ml IMIDAZOLE& 0.1ml CRYO]

• % ACTIVITYX DILUTION FACTORX VOLUME OF CRYO

• Eg:96X10X12mL = 111.20IU/BAG

• 100

Page 61: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Ensuring quality of the prepared blood components is the first step towards achieving optimum benefit to the patients

• Ensuring good clinical transfusion practices is of utmost importance for optimum benefit to patients

Page 62: Expectations  Vs  Achievements - Quality Control Of Blood Components

CLINICAL TRANSFUSION PROCESS

• The Transfusion of the right blood component to the right patient at the right time, in the right condition and according to appropriate guidelines

• A chain of integrated events that begins with a correct decision that the patient needs blood and ends with an assessment of the clinical outcome of the transfusion.

• Its goal is to achieve optimal use of blood

Page 63: Expectations  Vs  Achievements - Quality Control Of Blood Components

OPTIMAL USE OF BLOOD

• The safe, clinically effective and efficient use of donated human blood

• Safe: No adverse reactions or infections

• Clinically effective: Benefits the patient

• Efficient: No unnecessary transfusions

• Transfusion at the time the patient needs it

Page 64: Expectations  Vs  Achievements - Quality Control Of Blood Components

• AABB seeks to promote an interdisciplinary dialog that recognizes the critical importance of blood transfusion while also encouraging an approach to patient care that is designed to reduce the occurrence of preventable transfusions.

• Such an approach requires the involvement of clinicians, laboratory personnel, nursing staff, surgeons, anesthesiologists, and administrators.

Page 65: Expectations  Vs  Achievements - Quality Control Of Blood Components

QUALITY TRANSFUSION SERVICES• Clinical transfusion guidelines

• audit systems to monitor adherence to the guidelines

• the hemovigilance program which monitors the entire blood supply value chain,

Page 66: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Each of these systems has a different focus:

• the aim of clinical transfusion guidelines is to give direction to the clinician on when to transfuse and what the expected outcome should be.

• Guidelines are therefore a tool to ensure appropriate utilization of blood products.

• This is of critical importance in light of possible transfusion complications and a dwindling donor base.

Page 67: Expectations  Vs  Achievements - Quality Control Of Blood Components
Page 68: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Each patient must be evaluated individually and, if justified, the clinician can adjust the treatment guidelines for a specific patient.

• The decision to transfuse is therefore based ultimately on a clinical assessment of a specific patient’s condition and appropriate laboratory parameters.

• Transfusion therapy must always be of overall benefit to the patient.

Page 69: Expectations  Vs  Achievements - Quality Control Of Blood Components

• In the field of transfusion practice, controversies exist in the following areas -• When to transfuse?

• What to transfuse?

• How much to transfuse?

Page 70: Expectations  Vs  Achievements - Quality Control Of Blood Components

QUESTIONS TO BE ANSWERED IN THE

DECISION MAKING PROCESS

Page 71: Expectations  Vs  Achievements - Quality Control Of Blood Components

• What improvement in the patient’s clinical condition am I

aiming to achieve?

• Can I minimize blood loss to reduce this patient’s need for

transfusion?

• What are the specific clinical or laboratory indications for

transfusion for this patient?

• What is the time frame of decision making

urgent/elective?

Page 72: Expectations  Vs  Achievements - Quality Control Of Blood Components

• What are the risks of acquiring HIV/ hepatitis, through the blood products that are available for this patient?

• Do the benefits of transfusion outweigh the risks for this particular patient? How should the component be administered, monitored and its efficacy documented?

• Is the component easily available?

• What other options are there if no blood is available in time?

Page 73: Expectations  Vs  Achievements - Quality Control Of Blood Components

• Will a trained person monitor this patient and respond immediately if any acute transfusion reactions occur?

• Have I recorded my decision and reasons for transfusion on

the patient’s chart and the blood request form?

• Is the patient/relative fully informed and consenting to

medical decisions?

Page 74: Expectations  Vs  Achievements - Quality Control Of Blood Components

• The primary goal of modern blood transfusion therapy is to

ensure that the patients receive safe, reliable and effective

transfusion of the required blood components where the

benefits outweigh the risks.

• The transfusion medicine specialists plays an important role

in guiding the clinicians regarding good transfusion

practices and also ensure preparation of blood components

as per specifications of standards

Page 75: Expectations  Vs  Achievements - Quality Control Of Blood Components

THANK YOU