h-cooler- the new generation of

clinker cooler

Page 2: ETA Cooler 0204

About...

2

Claudius Peters TechnologiesGmbH, Germany and ClaudiusPeters Technologies S.A., Franceare part of the TechnologiesDivision of Claudius Peters GroupGmbH, headquartered inBuxtehude, near Hamburg,offering technologies in thefield of materials handlingand processing, providingturnkey and semi-turnkeysystems to a wide range ofindustries. Claudius Peters GroupGmbH is a wholly ownedsubsidiary of Langley Holdingsplc, a privately controlled UKengineering group, with regionaloffices in the Americas, Europe,China and the Far East.

Page 3: ETA Cooler 0204

3

Clinker Cooling has evolved...

With the ongoing innovation in cooler

technology since the 1950s, the

capacity of cement plants has

increased as their maintenance costs

and the wear and tear on parts have

reduced. These improvements have

largely been driven by design and

process technology solutions. At the

forefront of this effort for the past five

decades, Claudius Peters has been

responsible for many of the innovative

new developments that have led to

these advances.

Such developments include the

introduction of the hydraulic drive and

the roller crusher, as well as the wear-

free CSS (compact swing support). The

latest generation Claudius Peters

cooler, christened the -Cooler

incorporates a highly efficient transport

system. With a significantly reduced

number of parts, and no conveying

elements in the clinker bed,

maintenance costs and wear and tear

have been dramatically minimised.

Introduction

For over half a century, Claudius Peters

has had an established reputation as a

cooler specialist in the global cement

industry. The company began by

marketing in Europe the grate cooler

under licence from Fuller. Through its

own advancements and optimisations

on this design, Claudius Peters

developed its own grate cooler, which is

now in operation all over the world.

Many of these improvements - such as

the hydraulic grate drive (1975) and the

roller crusher (1979) - are now standard

elements for all cooler manufacturers

today.

In recent years, Claudius Peters' efforts

have been focused on achieving an

optimum clinker distribution over the

width of the reciprocating grates -

incorporated in the cross motion grate

in 2000 - as well as a fall through free

cooler with a low as construction height

as possible. This was achieved in a

cooler in 2001.

Page 4: ETA Cooler 0204

4

Static Inlet

HE Module Aeration

The complete lower section of the

h-Cooler is a modular design. Just two

different lengths of standard modular

elements are combined to optimise

cooler sizes from 1,000-12,000t/d. The

required cooler width is achieved by

modular design of the transport lanes.

Each module is delivered completely

pre-assembled, thereby minimising

erection times on site. The -Cooler

can be installed in the housings of

existing grate coolers with only minor

Static Inlet

The HE (High Efficiency) module

narrows in the direction of the inlet by

means of refractory concrete to achieve

an optimal clinker distribution on the

subsequent dynamic lanes.

With the HE module, which consists of a

static inclined grate, the risk of

snowmen forming is virtually eliminated,

while also ensuring a permanent clinker

layer on the module itself. The aeration

of the HE module is carried out via small

sections and the air quantity can be

adjusted by means of manual flaps.

Due to the flexibility of the air

distribution, it is possible to coincide

with the corresponding kiln discharge

conditions and the changing

environment due to the use of different

fuels and raw materials.

a Revolution in Clinker Cooling �

FEATURES

Example of transport principle for a 5-lane -Cooler

modifications. The conversion of an

existing grate cooler into a -Cooler is

therefore possible.

Page 5: ETA Cooler 0204

5

Depending on the required throughput

capacity, a corresponding number of

transport lanes are installed side by

side, each supported on rollers.

Due to the parallel, individually driven

and aerated transport lanes, the flow

behaviour and material speed at the

sides can be actively influenced,

thereby preventing a red river.

The slots for the air supply are

integrated in the transport lanes by

adapting the Mulden plate principle.

Each transport lane is sealed by means

of a labyrinth, which eliminates the need

for a dust removal system. This together

with the fact that the transport

system can be laid

horizontally makes

the -Cooler

d e s i g n

Transport System

The -Cooler uses a new transport

system for the cooler technique. This

system is based on the well proven

'walking floor' system that has long been

tested for bulk materials handling.

The -Cooler consists of parallel

transport lanes which are moved

together in the direction of the clinker

transport (forward stroke) and

individually or alternatively in

groups backwards

(backward stroke).

Cold clinker protects against hot material

Extremely compact design

No dust removal system required

Complete autogenous wear protection

Long strokes = low grate speed

Variable stroke length over the cooler width

No conveyor parts submerged in clinker� means less wear - significantly reducing exchange and maintenance work� no obstructions to the clinker flow � constant transport efficiency over cooler life� uniform cooling, since there are no un-aerated areas

Targeted air distribution - Chamber side aeration

� Optimum cooling

� Modular design - quick toinstall

� Optimal transversedistribution of clinker

� Higher transport efficiency

� Low operating costs

ADVANTAGES

extremely compact.

A particular advantage of the system is

that no installations inside the clinker

are needed for the material transport.

Aeration Concept

Since no installations inside the clinker

layer are needed the whole cooler

bottom is fully aerated leading to

uniform cooling and optimum

recuperation.

Additionally the -Cooler makes still use

of the chamber aeration principle - a

well proven aeration concept in grate

cooler design. However, in contrast to

reciprocating grate coolers the -design

allows for a longitudinal division into

chambers, which gives the advantage

of chamber side aeration, improving

cooling at the critical side areas of the

cooler and reducing the risk of red

rivers.

Page 6: ETA Cooler 0204

6

(eta) – the universal symbol for efficiency

A roller crusher for a 4,200-t/d operation

Drive System

The -Cooler is equipped with a

hydraulic cylinder drive. Depending on

the number of transport lanes, the

structure is modular and uses standard

parts, which do not require major

maintenance or adjustment. The

hydraulic cylinders attributed to each

transport lane make a long stroke

possible, which is controlled by an

integrated continuous position

measuring system.

The Claudius Peters RollerCrusher- The Original!

The roller crusher consists of air-cooled,

hydraulically or mechanically driven

rollers, whose operating width matches

the width of the cooler grate.

The number of rollers depends on the

clinker capacity to be crushed. Each

roller is equipped with high wear and

temperature resistant cast crushing

rings. The roller crusher is a modular

design for capacities up to 12,000t/d.

For high temperature crushing the roller

crusher is equipped with a cooling air

fan.

Due to the crushing method, the roller

crusher is able to continuously crush

large lumps up to 2 metres in diameter

without stalling. The low rotational

speed of the rollers guarantees the

highest possible lifetime and low

maintenance costs.

Features of Roller Crusher

� Can operate right behind the

recuperator zone� Slow roller speed, therefore minimal

wear� No refractory damage� Minimum dust generation� Long crushing life� Uniform particle size reduction over

long service life� Crushing of large lumps without kiln

stoppage� Low power consumption� Fully automated� Easy maintenance� High availability

Page 7: ETA Cooler 0204

7

The h--Cooler continues with the

Claudius Peters concept of low

maintenance and repair costs. The

modular design and reduced wear

mean major cost savings are

achievable. The transport system has

no conveying elements within the

clinker layer, which have to be replaced.

Furthermore, no dust removal system is

required, while an extremely low

construction height is called for. This all

adds up to lower investment and

operating costs for the cooler. Also,

again due to the modular design of the

h--Cooler, conversion times are greatly

reduced.

In short, whether it is a new plant or a

conversion, the h--Cooler offers the

most efficient operation in terms of

installation, heat recovery, transport

efficiency, repair costs and

maintenance costs.

Claudius Peters Measuring andControl Systems

Reliable and low cost operation

requires a modern automatic control

system.

Claudius Peters continues to develop

new features for optimum control of

the kiln-cooler process.

Claudius Peters Level Radar

The Level Radar system ensures

online measurement of the clinker

bed height in the cooler inlet, which is

the most critical area of a clinker

cooler.

This development is specifically

designed for abrasive, hot, dusty

conditions and gives a reliable and

exact signal for the clinker bed

height.

Tested over several years in various

plants, the Level Radar systems are

used for controlling the cooler grate

speed. Additionally, the unit is

designed to quickly recognise build-

ups in the cooler inlet area.� Continuous measuring of the

clinker bed height� No delay between appearance,

recognition and reaction� Automatic alarm and control to

prevent overfilling of cooler� Optimum automatic control of the

lane speed, resulting in a stable

combustion air temperature and

a smooth operating kiln� Installation in the kiln hood for all

existing plants

Claudius Peter TemperatureMeasuring Device

The gas temperatures within a clinker

cooler are an important aspect of the

process parameters of the system.

Claudius Peters has developed an

infrared sensor for quickly measuring

the gas temperature:� Infrared measuring sensor with 3°C

per second reaction time� Measuring range from 0 - 800°C

and 500 - 1500°C� Easy installation of air cooler probe� No regular maintenance required� Low investment costs with return of

investment (ROI) in months

Claudius Peter Full StrokeHydraulic Cylinder Drive

The EMC² (ETA Motion Control Centre)

controls and monitors all functions of

the lane/cylinder motion. This hydraulic

control system continuously measures

the position of the cylinders without

contacts to ensure the stroke length

required for each individual lane.

Conclusion

Page 8: ETA Cooler 0204

Claudius Peters Technologies GmbH

Schanzenstraße 40

D-21614 Buxtehude

Germany

Tel: +49 (0) 4161 706-0

Fax: +49 (0) 4161 706-270

[email protected]

Claudius Peters Technologies S.A.

34 Avenue de Suisse

F-68316 Illzach

France

Tel: +33 (0) 3 89 313 300

Fax: +33 (0) 3 89 619 525

[email protected]

Claudius Peters (Americas) Inc.

4141 Blue Lake Circle

Dallas, Texas 75244, USA

Tel: +1 972 386 4451

Fax: +1 972 386 4497

[email protected]

Claudius Peters (do Brasil) Ltda.

Rua Coral, 71 - Jardim do Mar

09725-650 São Bernardo do Campo

São Paulo, Brasil

Tel: +55 11 4337 4040

Fax: +55 11 4337 5017

[email protected]

Claudius Peters (UK) Ltd.

320 Kings Road, Reading

Berkshire, RG1 4JG, UK.

Tel: +44 (0)118 966 4555

Fax: +44 (0)118 966 9899

[email protected]

Claudius Peters (Ibérica) S.A.

Avenida de América, 37

1a Planta-Oficina 140

Edificio Torres Blancas

E-28002 Madrid, Spain

Tel: + 34 91 413 36 16

Fax: +34 91 519 69 56

[email protected]

Claudius Peters (Italiana) srl

Via Verdi, 2

I-24121 Bergamo, Italy

Tel: +39 0 35 237 196

Fax: +39 0 35 237 785

[email protected]

Claudius Peters (China) Ltd.

Unit A, 10/F

Two Chinachem Plaza

68 Connaught Road Central, Hong Kong

Tel: +852 2544 1848

Fax: +852 2854 0011

[email protected]

Branch Office:

10/F, Office Block

Hong Kong Macau Centre

No. 2 Chaoyangmen Bei Da Jie

Beijing 100027, P.R. China

Tel: +86 10 6501 3831

Fax: +86 10 6501 3803

[email protected]

Claudius Peters (Asia Pacific) Pte. Ltd.

25 International Business Park

#04-61 German Centre

Singapore 609916

Tel: +65 562 9100

Fax: +65 562 9109

[email protected]

A Langley Holdings Company

www.claudiuspeters.com

CPT 0004/02/04/1 Printed in England

CALCINING . COATING

COOLING . DISPATCH . DOSING

DRY BLENDING . DRYING

GRANULATION . GRINDING

PACKAGING . PNEUMATIC CONVEYANCE

PULVERIZED FUEL SUPPLY

SILO SYSTEMS . STOCKYARD SYSTEMS

TURNKEY PROJECTS

The information contained within this brochure is deemed to be correct at the time of goingto press. Due to the policy of continued improvement, we reserve the right to change anyspecification without prior notice. ERRORS & OMISSIONS EXCEPTED