espan 340™ / 470™ · pre-finished flat head wafer-tek screw for flashing pre-finished window...
TRANSCRIPT
00 / 21 COVER SHEET01 / 21 PARAPET AND BALUSTRADE CAPPING02 / 21 SCUPPER W/ RAINWATER HEAD03 / 21 SOFFIT04 / 21 BUTT WINDOW HEAD05 / 21 BUTT WINDOW SILL06 / 21 BUTT WINDOW JAMB07 / 21 RECESSED WINDOW HEAD08 / 21 RECESSED WINDOW SILL09 / 21 RECESSED WINDOW JAMB10 / 21 METERBOX HEAD11 / 21 METERBOX SILL12 / 21 METERBOX JAMB13 / 21 INTERNAL CORNER14 / 21 EXTERNAL CORNER15 / 21 SOAKER FLASHING16 / 21 CHANGE IN CLADDING17 / 21 CLADDING ABUTMENT18 / 21 BOTTOM OF CLADDING (FLUSH)19 / 21 BOTTOM OF CLADDING (RECESSED)20 / 21 3D WINDOW FLASHINGS21 / 21 3D RAINWATER HEAD
DETAIL LISTCOMMERCIAL VERTICAL CLADDING
Espan 340™ / 470™
CVEP
0800 ROOFNZ (0800 766 369)www.metalcraftgroup.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
PRE-FINISHED PARAPET CAPFLASHINGNO FIXINGS ON TOP OF FLASHING
PERMEABLE WALLUNDERLAY, SHOWNDASHED
PRE-FINISHED SELF DRILLING /TAPPING SCREW WITH RUBBERWASHER FOR FIXING TOP OFESPAN™ CLADDING
METALCRAFT ESPAN™ VERTICALCLADDING
METALCRAFT MSS PURLINBY ENGINEER
CONTINUOUS TIMBER PACKING MIN
. 5°
PERMEABLE WALL UNDERLAY TOPROVIDE SEPARATION OF METALCAPPING AND TIMBER, SHOWNDASHED
PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW
STOPENDS TO WALL CLADDING
20mm HORIZONTAL CAVITY BATTEN
CLE
ARAN
CE
25m
m M
IN
5mm GAP
MIN
. 5.00 °
ALTERNATIVE OPTION
5mm GAP
5mm GAP
CLE
ARAN
CE
25m
m M
IN.
CLE
A RAN
CE
3mm
MIN
COMPRESSIBLE FOAMSEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012 FOR REQUIRMENT.
Z
Z
Z
CATEGORY A
1. NORMAL EXPOSURE2. ROOF PITCH >10°
MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)
CATEGORY B
1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°
MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)
MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)
Z
ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE
SITUATION 1
1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°
MIN. 50mm
SITUATION 2
1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°
MIN. 70mmZ
SITUATION 3
1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES
MIN. 90mm
ACCEPTABLE SOLUTION AS PER E2/ASI
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
PARAPET AND BALUSTRADE CAPPING
01 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
METALCRAFT ESPAN™ VERTICALCLADDING
PERMEABLE WALLUNDERLAY, SHOWNDASHED
20mm HORIZONTALCAVITY BATTEN
WALL FRAMING
CAVITY CLOSER
RETURN MEMBRANE INTORAINWATER HEAD
CONTINUOUS MEMBRANEDRESSED THROUGH BASE ANDUP SIDES OF OPENING WITHUPPER EDGES SEALED AGAINSTCLADDING. RETURN ALONGBACK OF RAINWATERHEAD
RAINWATER HEAD
RETURN MEMBRANEAT END OF LIP
MEMBRANE ON ROOFSUBSTRATE
8g WAFER-TEK SCREW
TRUE ROOF LINE BEHIND
PRE FINISHED SCREWWITH RUBBER WASHER
25RAINWATER HEADOVERFLOW BELOWOPEINING LEVEL,1.5 xCROSS-SECTIONDOWNPIPE DIAMETER
50 mm
SEPARATE BATTEN ANDCLADDING ASREQUIRED WITH EPDM
ALTERNATIVE OPTION
METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 16mm WAFERTEK
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
SCUPPER W/ RAINWATER HEAD
02 / 212018
METALCRAFT MSS PURLINBY ENGINEER
INTERNAL WALL LINING
METALCRAFT MSS PURLIN BY ENGINEER
20mm HORIZONTAL CAVITYBATTEN
SEPARATE BATTEN ANDCLADDING WITH DPC ASREQUIRED
BARGE BOARD
SOFFIT LINING
METALCRAFTMSS PURLIN BYENGINEER
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER FORFIXING TOP OF ESPAN™CLADDING
INTERNAL CEILING LINING
COMPRESSIBLE FOAM SEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2 /2012 FOR REQUIRMENT.
PRE-FINISHEDSOFFIT FLASHING
PRE-FINISHED FLAT HEAD WAFER-TEK SCREWFOR FLASHING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
METALCRAFT ESPAN™ VERTICALCLADDING
PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW
STOPENDS TO WALL CLADDING
5mm GAP50mm MIN
100m
m M
IN
MIN. 50mm
100m
m M
IN
5mm GAP
ALTERNATIVE OPTION
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
SOFFIT
03 / 212018
BUILDING PAPER DRESSED INTOOPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED
INTERNAL WALL LINING
METALCRAFT ESPAN™ VERTICALCLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMBLINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
METALCRAFT MSS PURLINS BYENGINEER
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 16mm WAFER-TEK
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
CAVITY CLOSER AS REQUIRED TONZBC
5mm
GAP
MIN
. 10m
m C
OVE
R
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
TO
SU
ITDR
IP E
DG
E TO
CLA
DD
ING
MIN
.15m
m G
AP
MIN
.75m
m W
ITH
OU
T H
EM E
DG
E
MIN
.50m
m C
OVE
R
20mm HORIZONTAL CAVITY BATTEN
5mm
GAP
MIN
. 10m
m C
OVE
R
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
S TO
SU
ITDR
IP E
DG
E TO
CLA
DD
I NG
MIN
. 15m
m
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
ALTERNATIVE OPTION
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
BUTT WINDOW HEAD
04 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
PRE-FINISHED WINDOW SILL FLASHING
LINE OF WINDOW JAMBLINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TORUN CONTINUOUSLY AROUNDHEAD, SILL AND JAMB
INTERNAL WALL LINING
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFIXING TOP OF ESPAN™ CLADDING
20mm HORIZONTAL CAVITY BATTEN
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL
DOUBLE GLAZING WINDOW JOINERY
METALCRAFT MSS PURLIN BYENGINEER
COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
SEPARATE BATTEN AND CLADDINGWITH DPC AS REQUIRED
WINDOW SILL SUPPORT BAR
5mm GAP
CO
VER
CLA
DD
ING
60m
m
5mm
GAP
MIN
. 8m
m C
OVE
R
ALTERNATIVE OPTION
5mm GAP
CO
VER
CLA
DD
ING
60m
m
5mm
GAP
MIN
. 8m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet
- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.
1 : 2
BUTT WINDOW SILL
05 / 212018
PRE-FINISHED WINDOW JAMB FLASHING
DOUBLE GLAZING WINDOW JOINERY
LINE OF SILL FLASHING BELOW
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
PRE-FINISHED FIXING BRACKET WITH PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™VERTICAL CLADDING
MIN.10mm COVER
5mm GAP
INTERNAL WALL LINING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
20mm JAMB BATTEN
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL
METALCRAFT MSS PURLIN BYENGINEER
SUGGEST MIN.50mm
DIMENSION TO SUIT
PRE-FINISHED SECONDARYFLASHING
LINE OF SILL FLASHING BELOW
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
LINE OF HEAD FLASHING ABOVE
LINE OF HEAD FLASHING ABOVE
SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED
5mm
GAP
20mm HORIZONTAL CAVITYBATTEN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet
- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.
1 : 2
BUTT WINDOW JAMB
06 / 212018
PERMEABLE WALL UNDERLAYDRESSED INTO OPENING WITHFLEXIBLE FLASHING TAPE INSTALLEDOVER WRAP TO CORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING,SHOWN DASHED
INTERNAL WALL LINING
METALCRAFT ESPAN™ VERTICALCLADDING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMBLINER BEHIND
STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
MIN
. 10m
m C
OVE
R
METALCRAFT MSS PURLINS BYENGINEER
METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 16mm WAFER-TEK
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
MIN
15
mm
GAP
MIN
. 75m
m W
ITH
OU
T H
EM E
DG
E
MIN
50m
m C
OVE
R
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
TO
SU
IT
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
CAVITY CLOSER AS REQUIRED TONZBC
5mm
GAP
20mm HORIZONTAL CAVITY BATTEN
5mm
GAP DR
IP E
DG
E TO
CLA
DD
I NG
MIN
15m
m G
AP
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
SUG
GES
T M
IN. 5
0mm
DIM
ENSI
ON
TO
SU
IT
10m
m M
IN C
OVE
R
ALTERNATIVE OPTION
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
RECESSED WINDOW HEAD
07 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
PRE-FINISHED WINDOW SILL FLASHING
LINE OF WINDOW JAMBLINER BEHIND
WINDOW SILL LINER
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TORUN CONTINUOUSLY AROUNDHEAD, SILL AND JAMB
INTERNAL WALL LINING
STOPENDS TO SILL FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFIXING TOP OF ESPAN™ CLADDING
20mm HORIZONTAL CAVITY BATTEN
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FORFULL WIDTH/DEPTH SILL
DOUBLE GLAZING WINDOW JOINERY
METALCRAFT MSS PURLIN BYENGINEER
COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED
WINDOW SILL SUPPORT BAR
5mm GAP
CO
VER
CLA
DD
ING
60m
m
5mm
GAP
MIN
. 8m
m C
OVE
R
ALTERNATIVE OPTION
5mm GAP
CO
VER
CLA
DD
ING
60m
m
5mm
GAP
MIN
. 8m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
RECESSED WINDOW SILL
08 / 212018
PRE-FINISHED WINDOW JAMB FLASHING
DOUBLE GLAZING WINDOW JOINERY
LINE OF SILL FLASHING BELOW
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
PRE-FINISHED FIXING BRACKET WITH PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW
METALCRAFT ESPAN™ VERTICALCLADDING
MIN. 10mm COVER
INTERNAL WALL LINING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
LINE OF WINDOW SILL LINER BELOW
WINDOW JAMB LINER
TIMBER PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
20mm JAMB BATTEN
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL
METALCRAFT MSS PURLIN BYENGINEER
PRE-FINISHED SECONDARYFLASHING
LINE OF SILL FLASHING BELOW
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
LINE OF HEAD FLASHING ABOVE
SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED
SUGGEST MIN. 50mm
DIMENSION TO SUIT
5mm GAP
LINE OF HEAD FLASHING ABOVE
20mm HORIZONTAL CAVITYBATTEN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
RECESSED WINDOW JAMB
09 / 212018
PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TOCORNERS AT HEAD
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED
METALCRAFT ESPAN™ VERTICALCLADDING
PRE-FINISHED HEAD FLASHINGWITH 15° FALL
METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 16mm WAFER-TEK
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB
METER BOX STOPENDS TO HEAD FLASHING
LINE OF JAMB FLASHING BEHIND
PRE-FINISHED 'U' BRACKET FIXED TOMETERBOX BEFORE INSTALLATION
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
INTERNAL WALL LINING
METALCRAFT MSS PURLINS BYENGINEER
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW FOR FLASHING
CAVITY CLOSER AS REQUIRED TO NZBC
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
20mm HORIZONTAL CAVITY BATTEN
5mm
GAP
MIN
. 15m
m G
AP
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
ALTERNATIVE OPTION
5mm
GAP
MIN
. 15m
m G
AP
MIN
. 75m
m W
I TH
OU
T H
EM E
DG
E
MIN
. 50m
m C
OVE
R
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
METERBOX HEAD
10 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
PERMEABLE WALL UNERLAY,SHOWN DASHED
METER BOX
MIN. 8mm PACKER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB
METALCRAFT MSS PURLINBY ENGINEER
INTERNAL WALL LINING
LINE OF JAMB FLASHING BEHIND
20mm HORIZONTAL CAVITY BATTEN
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX. PRE-FINISHED FLASHING FIXED TO
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED
CO
VER
CLA
DD
NIN
G
60m
m M
IN
STOPENDS TO SILL FLASHING
COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.
STOPENDS TO WALL CLADDING
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFIXING TOP OF ESPAN™ CLADDING
5mm GAP
5mm gap
ALTERNATIVE OPTION
CO
VER
CLA
DD
ING
60m
m M
IN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
METERBOX SILL
11 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
PERMEABLE WALL UNDERLAY,SHOWN DASHED
METER BOX
TIMBER PACKER
20mm JAMB BATTEN
LINE OF SILL FLASHING BELOW
FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
LINE OF HEAD FLASHING ABOVE
PRE-FINISHED JAMB FLASHING FIXEDTO METERBOX BEFORE INSTALLATION
AIRSEAL ON BACKING ROD
METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.
INTERNAL WALL LINING METALCRAFT MSS PURLINBY ENGINEER
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB
PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW
LINE OF HEAD FLASHING ABOVE
LINE OF SILL FLASHING BELOW
20mm HORIZONTAL CAVITYBATTEN
5mm
GAP
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
METERBOX JAMB
12 / 212018
METALCRAFT ESPAN™VERTICAL CLADDING
20mm HORIZONTAL CAVITYBATTEN
PRE-FINISHED INTERNALCORNER FLASHING
INTERNAL WALL LINING
PERMEABLE WALLUNDERLAY, SHOWN DASHED
STRUCTURAL COLUMN BYENGINEER
METALCRAFT MSS PURLINBY ENGINEERPRE-FINISHED FLAT
HEAD WAFER-TEKSCREW WITH EPDMWASHER
PRE-FINISHED SECONDARYFLASHING
SEPERATE BATTEN ANDCLADDING WITH DPC ASREQUIRED
5mm GAP
5mm
GAP
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
INTERNAL CORNER
13 / 212018
METALCRAFT MSS PURLIN BYENGINEER
20mm HORIZONTAL CAVITYBATTEN
PRE-FINISHED EXTERNALCORNER FLASHING
PERMEABLE WALL UNDERLAY, SHOWNDASHED
METALCRAFT ESPAN™ VERTICALCLADDING
STRUCTURAL COLUMN BY ENGINEER
PRE-FINISHED FLAT HEAD WAFER-TEKSCREW WITH EPDM WASHER
SEPERATE BATTEN AND CLADDING WITHDPC AS REQUIRED
5mm
GAP
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
EXTERNAL CORNER
14 / 212018
PERMEABLE WALLUNDERLAY, SHOWN DASHED
METALCRAFT ESPANVERTICAL CLADDING
PRE-FINISHED FLAT HEADWAFER-TEK SCREW WITHEPDM WASHER
INTERNAL WALL LINING
SEPARATE BATTEN ANDFLASHING WITH DPC ASREQUIRED
METALCRAFT MSS PURLINBY ENGINEER
PRE-FINISHED SOAKERFLASHING TO LINE UP WITHWINDOW JAMB ABOVE
20mm HORIZONTAL CAVITYBATTEN
METALCRAFT MSS PURLINBY ENGINEER
SOAKER FLASHING ONLY REQUIRED TOLINE UP WITH WINDOW JAMB ABOVE.REFER TO MRM CODE OF PRACTICEVERSION 2.2 /2012 FOR REQUIRMENT.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
SOAKER FLASHING
15 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
PRE FINISHED SCREWWITH RUBBERWASHER
20mm HORIZONTAL CAVITYBATTEN FIBRE CEMENT BOARD
BY OTHERS
PRE FINISHEDALUMINIUM FLASHING
PERMEABLE WALLUNDERLAY, SHOWNDASHED
INTERNAL WALL LINING
SEPARATE BATTEN AND FLASHING ASREQUIRED WITH DPC
5mm
GAP
MIN. 50mm
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
CHANGE IN CLADDING
16 / 212018
METALCRAFT ESPAN™ VERTICALCLADDING
WALL FRAMINGPRE FINISHED SCREWWITH RUBBERWASHER
CONCRETE WALL BYOTHERS
CONTINUOUS AIR SEAL ONBACKING ROD
DPC
PRE FINISHED ALUMINIUMFLASHING
20mm HORIZONTALCAVITY BATTENSS
PRE-FINISHED POP RIVETBEDDED IN SILICONE
PERMEABLE WALLUNDERLAY, SHOWNDASHED
SEPARATE BATTEN ANDFLASHING AS REQUIREDWITH EPDM
INTERNAL WALLLINING
PRE-FINISHEDSECONDARY FLASHING
Mastic bead
5mm
GAP
ALTERNATIVE OPTION
Rawlplug
5mm
GAP
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
CLADDING ABUTMENT
17 / 212018
PERMEABLE WALL UNDERLAY, SHOWNDASHED
INTERNAL WALL LININGMETALCRAFT ESPAN™ VERTICALCLADDING
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
CAVITY CLOSER AS REQUIRED TONZBC
PRE-PRIMED SKIRTING
CONCRETE SLAB
METALCRAFT MSS PURLIN BYENGINEER
METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 16mm WAFER-TEK 20mm HORIZONTAL CAVITY BATTEN
PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL
3-5m
m V
ENTI
LATI
ON
GAP
DR
IP E
DG
E TO
CLA
DD
ING
MIN
. 15m
m G
AP
MIN
. 50m
m L
AP
SEPERATE BATTEN AND FLASHINGAS REQUIRED WITH DPC
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
BOTTOM OF CLADDING (FLUSH)
18 / 212018
PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED
METALCRAFT ESPAN™ VERTICALCLADDING
METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 16mm WAFER-TEK
PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL
INTERNAL WALL LINING
PRE-PRIMED SKIRTING
CONCRETE SLAB
CAVITY CLOSER AS REQUIRED TONZBC
PRE-FINISHED FLAT HEAD WAFER-TEK SCREW FOR FLASHING
20mm HORIZONTAL CAVITY BATTEN
3-5m
m V
ENTI
LATI
ON
GAP
MIN
. 50m
m L
APM
IN. 7
5mm
CO
VER
ALTERNATIVE OPTION
6mm GAP
SEPERATE BATTEN AND CLADDING ASREQUIRED WITH DPC
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet 1 : 2
BOTTOM OF CLADDING (RECESSED)
19 / 212018
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet
3D WINDOW FLASHINGS
20 / 212018
RECESSED WINDOW FLASHINGS
HEAD FLASHING
JAMB FLASHING
SILL FLASHING
ALUMINIUMWINDOWJOINERY
METALCRAFTESPAN™ VERTICALCLADDING
LIP OF DISCHARGE AT LOWEST POINTOF ROOF
DOWNPIPE
OVERFLOW BELOW OPENING LEVEL, 1.5 xCROSS-SECTION AREA OF DOWNPIPE
METALCRAFT ESPAN™ VERTICALCLADDING
OPENING200mm MIN
EITHER SIDE
50mm MIN
OPE
NIN
G
75m
m M
IN
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
COMMERCIAL VERTICAL CLADDING
CVEP
Espan 340 / 470™
- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.
ScaleDate Sheet
3D RAINWATER HEAD
21 / 212018