equipment for engineering education & research continuous...

4
Equipment for Engineering Education & Research SOLTEQ ® CONTINUOUS STIRRED TANK REACTOR MODEL: BP 100 HE Continuous Stirred Tank Reactor (Model: BP 100) has been designed to introduce students of Chemical Engineering on reactor and reaction behaviour. This type of reactor is one of the most important industrial reactors. The unit comes with all the ancillary equipment except analytical instrumentation for the T measurement of the composition of feed and product mixtures. The unit includes a reactor vessel of approximately 4 litres total capacity, and is equipped with a variable speed stirrer with digital display, inlet and outlet ports for the feed and product streams, sampling, temperature measurement and control. The reactant volume is adjustable by an overflow device. Two non-corroding feed storage vessels are supplied, together with chemically resistant pumps and flowmeters. A product collection vessel is also provided, thus allowing approximately 1 to 2 hours continuous operation. The reactor comes with a cooling coil for maintaining the reaction temperature. A digital temperature controller is also provided on the front panel. Both exothermic and endothermic reactions can therefore be carried out at constant temperature up to approximately 80 o C. A conductivity meter is provided for the purpose of determining the extent of conversion. A gas feed line is included, complete with a gas sparging ring, a flowmeter and a flow regulating valve to facilitate gas- liquid reactions: e.g., oxidation.

Upload: others

Post on 10-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Equipment for Engineering Education & ResearchSOLTEQ®

CONTINUOUS STIRRED

TANK REACTORMODEL: BP 100

HE Continuous Stirred Tank Reactor (Model: BP 100) has been designed to introduce students of

Chemical Engineering on reactor and reaction behaviour. This type of reactor is one of the most important

industrial reactors. The unit comes with all the ancillary equipment except analytical instrumentation for theT

measurement of the composition of feed and product mixtures.

The unit includes a reactor vessel of approximately 4

litres total capacity, and is equipped with a variable

speed stirrer with digital display, inlet and outlet ports for

the feed and product streams, sampling, temperature

measurement and control. The reactant volume is

adjustable by an overflow device. Two non-corroding

feed storage vessels are supplied, together with

chemically resistant pumps and flowmeters. A product

collection vessel is also provided, thus allowing

approximately 1 to 2 hours continuous operation.

The reactor comes with a cooling coil for maintaining

the reaction temperature. A digital temperature controller

is also provided on the front panel. Both exothermic

and endothermic reactions can therefore be carried out

at constant temperature up to approximately 80 oC. A

conductivity meter is provided for the purpose of

determining the extent of conversion. A gas feed line is

included, complete with a gas sparging ring, a

flowmeter and a flow regulating valve to facilitate gas-

liquid reactions: e.g., oxidation.

Equipment for Engineering Education & ResearchSOLTEQ®

SOLTEQ

EXPERIMENT CAPABILITIES

♦ Chemical kinetic studies

♦ Batch or continuous operations

♦ Effect of residence time

♦ Effect of temperature

♦ Mixing effects

♦ Heat transfer

SPECIFICATIONS

Bench-mounted apparatus designed to demonstrate

reaction behaviour, including homogeneous and gas-

liquid reactions, allowing 1 to 2 hours continuous

operation. Integral heating and mains water cooling with

connections to laboratory supplies.

REACTOR:

Material : borosilicate glass; stainless steel

top and bottom plate

Total Volume : 4 L

Working Volume : 2 to 3.5 litre (adjustable)

Cooling System : cooling water through stainless

steel cooling coil

Heating System : 1.5 kW; immersion heater;

Temperature Sensor;

Temperature Controller

Gas Sparger : perforated stainless steel tube

Sample analysis : sampling valves (analytical

instruments are not included)

STIRRER SYSTEM:

Motor Rating : 75 W (input); 55 W (output)

Variable Speed : 50 to 2,000 rpm; with speed

controller and LCD indicator

Impellers : 2” dia.; stainless steel

Electrical : 240VAC/1-phase/50-60Hz.

FEED TANKS:

Capacity : 30 litre (cylindrical)

Material : Stainless steel

PRODUCT TANKS:

Capacity : 60 litre (rectangular)

Material : Stainless steel

FEED PUMPS:

Capacity : 1 LPM

Electrical : 240VAC/1-phase/50-60Hz.

FLOW CONTROL:

Liquid Flowmeter : up to 500 ml/min; electronic

Gas Flowmeter : up to 30 LPM; electronic

Control valves : needle valves

INSTRUMENTATIONS:

The unit is fitted with all necessary instruments for the

measurements of reaction temperature, reactants flow

rates, and conductivity.

OPTIONAL ITEMS

- EI

DIGITAL INSTRUMENTATIONS

i) 3 units of electronic flow meter with digital display

ii) 1 unit of conductivity sensor with monitor

iii) 1 unit of temperature sensor with digital display

- DAS

SOLDAS DATA ACQUISITION SYSTEM

i) A PC with Pentium processor

ii) A signal conditioning unit

iii) A stand alone data acquisition modules

iv) A Windows based software

♦ Data Logging

♦ Signal Analysis

♦ Process Control

♦ Real-Time Display

♦ Tabulated Results

♦ Graph of Experimental Results

- CAL

SOLCAL COMPUTER AIDED LEARNING SOFTWARE

i) Interactive multimedia features

ii) Graphical simulation

iii) Experiment results samples

iv) Full experiment manuals

TYPICAL EXPERIMENT RESULTS

SOLTEQ

REQUIREMENTS

♦ Electrical supply : 240VAC/1-phase/50-60Hz.

♦ Water supply : Laboratory mains supply with

drainage points

♦ Working area : ventilated; approx. 10 m2

♦ Chemicals : ethyl acetate and caustic soda

are suggested

♦ Gas cylinder for optional gas-liquid reaction

♦ Analytical equipment

OVERALL DIMENSIONS

Height: 1.52 m

Width: 1.22 m

Depth: 0.91 m

MANUAL

The unit is supplied with Operating and Experiment

Manuals in English giving full descriptions of the unit,

summary of theory, experimental procedures and

typical experimental results.

EXPERIMENT A

BATCH REACTION

0

0.5

1

1.5

2

2.5

3

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Time(min)

Conc. of Ethyl Acetate with

NaO

H

EXPER IMENT B

PLOT (InC b/C a vs . t )

0

0.5

1

1.5

2

2.5

0 5 10 15 20 25 30 35 40 45

T im e(m in )

In(Cb/Ca)

Equipment for Engineering Education & ResearchSOLTEQ®

SOFTWARE & E-LEARNING

Our range of teaching equipment can be complemented with our

SOLDAS and SOLCAL software.

SOLDAS - Supervisory Control & Data Acquisition

- Data Logging

- Signal Analysis

- Process Control

- Real-Time Display

- Tabulated Results

- Graph of Experiment Results

SOLCAL - Computer Aided Learning

- Multimedia Features

- Interactive

- Graphic Simulation

- Samples of Experiment Result

- Full Experiment Manuals

Contact us for a catalog CD

SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)

Sales Office :

No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000

Fax. No. : +(603) 80755784

R&D Office :

G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023

Email : [email protected] site : http//www.solution.com.my/

AGENT:

BUATAN MALAYSIA

MSC- StatusCompany

®

®