eicos sensors for fluid flow monitoring - catalogue · 2020. 4. 29. · eiconet material {80g 53 26...

16
eicos.net Material { 80g 53 26 49 13 98 32 Ø12 FE14B02-M12 0 3LPM Flow Switch for liquids Datasheet How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch). Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹. Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring. Liquids • Clean water, oils, lubricants and filtered fuels². Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor. Liquids with encrustation particles and/or solids require tests. Technical specifications Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%. • Typical connection to contactor Mounting (Important!) Flow Switches and Level Switches for liquids flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector The sensors work in all voltage and current ranges displayed in the table bellow: Operating Voltage Max. Switching Power Max. Switching Current Peak Current 110Vac 20VA 0.2A 0.5A @20ms 220Vac 20VA 0.1A 0.5A @20ms 5Vdc 2.5W 0.5A 1A @20ms 12Vdc 5W 0.5A 1A @20ms 24Vdc 10W 0.5A 1A @20ms 24Vac: Recommended use with Schneider coupling relay model RSLZVA1. G 1/4” Connection - FE Series C.02/Apr2020 PPA - Polyphthalamide Internal clearance 4mm² Maximum operation pressure 25bar Operating temperature range 0°C to 100°C | 140°C @1h Inlet/outlet port G 1/4” female (BSP - Parallel) Spring AISI 304 stainless steel Sealing NBR (nitrilic rubber) O’Ring Output connection M12 male plug (2 pins) M12 female connector NOT included Enclosure rating IP66 Electrical contact Reed Switch 20W/VA Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL 1-BR • 2 pins M12 Connector Flow Switch M12 Plug Sensors Installation WRONG Dimensions (mm) and Weight Inlet Fitting Outlet Fitting Flow Direction Hex screw for sensitivity adjustment ASCENDING FLOW K8 for AC KD for DC Snubber Filter 2 For application in oil, recommended model FE14B04-M12. Actuation Range (in LPM) Water Oil 68 cSt @ 40°C From ~0.2 to ~3.0 From ~0.01 to ~0.21 FLOW INCREASE - ON FLOW DECREASE - OFF

Upload: others

Post on 15-Feb-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

  • eicos.net

    Material

    {

    80g53

    26

    49

    13

    98

    32

    Ø12

    FE14B02-M12

    0 3LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1/4” Connection - FE Series C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 4mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/4” female (BSP - Parallel)Spring AISI 304 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL

    1-BR

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    WRONG

    Dimensions (mm) and Weight

    Inlet Fitting

    Outlet Fitting

    Flow Direction

    Hex screw for sensitivity adjustment

    ASC

    END

    ING

    FLO

    W

    K8 for ACKD for DC

    Snubber Filter

    2 For application in oil, recommended model FE14B04-M12.

    Actuation Range (in LPM)Water Oil 68 cSt @ 40°C

    From ~0.2 to ~3.0 From ~0.01 to ~0.21

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

  • eicos.net

    Material

    {

    80g53

    26

    49

    13

    98

    32

    Ø12

    FE14B04-M12

    0 4LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1/4” Connection - FE Series C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 4mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/4” female (BSP - Parallel)Spring AISI 304 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL

    1-BR

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    WRONG

    Dimensions (mm) and Weight

    Inlet Fitting

    Outlet Fitting

    Flow Direction

    Hex screw for sensitivity adjustment

    ASC

    END

    ING

    FLO

    W

    K8 for ACKD for DC

    Snubber Filter

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water Oil 68 cSt @ 40°C

    From ~0.4 to ~4.0 From ~0.01 to ~0.65

    fuels.

  • eicos.net

    Material

    {

    71g53

    26

    49

    13

    98

    32

    Ø12

    FA14B02-M12

    0 5LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 8mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/4” female (BSP - Parallel)Spring AISI 304 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/4” Connection - FA Series C.01/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL

    1-BR

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    WRONG

    Dimensions (mm) and Weight

    Inlet Fitting

    Outlet Fitting

    Flow Direction

    Hex screw for sensitivity adjustment

    ASC

    END

    ING

    FLO

    W

    K8 for ACKD for DC

    Snubber Filter

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water Oil 68 cSt @ 40°C

    From ~0.8 to ~5.0 From ~0.05 to ~0.50

    2 For application in oil, recommended model FA14B04-M12. For application in viscous oil, recommended model FA14B06-M12.

  • eicos.net

    Material

    {

    71g53

    26

    49

    13

    98

    32

    Ø12

    FA14B04-M12

    0 7LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 8mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/4” female (BSP - Parallel)Spring AISI 304 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/4” Connection - FA Series C.01/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL

    1-BR

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    WRONG

    Dimensions (mm) and Weight

    Inlet Fitting

    Outlet Fitting

    Flow Direction

    Hex screw for sensitivity adjustment

    ASC

    END

    ING

    FLO

    W

    K8 for ACKD for DC

    Snubber Filter

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water Oil 68 cSt @ 40°C

    From ~1.7 to ~7.0 From ~0.30 to ~0.60

    2 For application in viscous oil, recommended model FA14B06-M12.

  • eicos.net

    Material

    {

    71g53

    26

    49

    13

    98

    32

    Ø12

    FA14B06-M12

    0 8LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 8mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/4” female (BSP - Parallel)Spring AISI 304 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/4” Connection - FA Series C.01/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact. 3-BL

    1-BR

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    WRONG

    Dimensions (mm) and Weight

    Inlet Fitting

    Outlet Fitting

    Flow Direction

    Hex screw for sensitivity adjustment

    ASC

    END

    ING

    FLO

    W

    K8 for ACKD for DC

    Snubber Filter

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water Oil 68 cSt @ 40°C

    From ~2.5 to ~8.0 From ~0.40 to ~0.70

    2 For application in oil, also recommended model FA14B04-M12.

  • eicos.net

    Material{

    200g

    120 32

    87

    FH12B02-M12

    0 17LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 114mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/2” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/2” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    1-BR

    WRONG

    CORRECT

    Dimensions (mm) and Weight

    FLO

    W

    FLOW

    3-BL

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    Hex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~0.3 to ~17

    2 For application in oil, recommended model FH12B04-M12. For application in viscous oil, recommended model FH12B06-M12.

  • eicos.net

    Material{

    200g

    120 32

    87

    0 29LPM

    FH12B04-M12

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 114mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/2” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/2” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    1-BR

    WRONG

    CORRECT

    Dimensions (mm) and Weight

    FLO

    W

    FLOW

    3-BL

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    Hex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~0.6 to ~29

    2 For application in viscous oil, recommended model FH12B06-M12.

  • eicos.net

    Material{

    200g

    120 32

    87

    0 34LPM

    FH12B06-M12

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    Internal clearance 114mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1/2” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    G 1/2” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    1-BR

    WRONG

    CORRECT

    Dimensions (mm) and Weight

    FLO

    W

    FLOW

    3-BL

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    Hex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~1.0 to ~34

    2 For application in oil, also recommended model FH12B04-M12.

  • eicos.net

    Material

    {

    94

    38140

    300g

    FC34B02-M12

    0 52LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 3/4” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 266mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 3/4” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    1-BR

    3-BL

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~2.1 to ~52

    2 For application in oil, recommended model FC34B04-M12.

  • eicos.net

    Material

    {

    94

    38140

    300g

    FC34B04-M12

    0 72LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 3/4” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 266mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 3/4” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection M12 male plug (2 pins)

    M12 female connector NOT includedEnclosure rating IP66

    Electrical contact Reed Switch 20W/VA

    1-BR

    3-BL

    • 2 pinsM12 Connector

    Flow Switch

    M12 Plug Sensors Installation

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~3.2 to ~72

    fuels.

  • eicos.net

    Material

    } 138

    50

    108

    50

    495g

    FC10B02

    0 78LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 380mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW DECREASE - OFF

    FLOW INCREASE - ON Actuation Range (in LPM)Water

    From ~2.5 to ~78

    2 For application in oil, recommended model FC10B04.

  • eicos.net

    Material

    } 138

    50

    108

    50

    495g

    FC10B04

    0 104LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 380mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’RingOutput connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~4.3 to ~104

    fuels.

  • eicos.net

    Material

    151

    68

    129

    76{

    760g

    FJ112B02

    0 112LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1½” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 680mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1½” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’Ring³Output connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW DECREASE - OFF

    FLOW INCREASE - ON Actuation Range (in LPM)Water

    From ~2.5 to ~112

    2 For application in oil, recommended model FJ112B04.3 Not included with the product.

  • eicos.net

    Material

    151

    68

    129

    76{

    760g

    FJ112B04

    0 140LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 1½” Connection C.02/Apr2020

    PPA - Polyphthalamide

    Internal clearance 680mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 1½” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’Ring³Output connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Dimensions (mm) and WeightHex screw for sensitivity adjustment

    FLOW INCREASE - ON

    FLOW DECREASE - OFF

    Actuation Range (in LPM)Water

    From ~3.3 to ~140

    2 Not included with the product.

    fuels.

    Ring²

  • eicos.net

    Material

    { 154 74

    150

    FG20B02

    0 136LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 2” Connection C.02/Apr2020

    316 Stainless Steel(PPA piston)

    Internal clearance 1000mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 2” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’Ring³Output connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    2.8KgDimensions (mm) and Weight

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Hex screw for sensitivity adjustment

    FLOW DECREASE - OFF

    FLOW INCREASE - ON Actuation Range (in LPM)Water

    From ~8.8 to ~136

    2 For application in oil, recommended model FG20B04.3 Not included with the product.

  • eicos.net

    Material

    { 154 74

    150

    FG20B04

    0 145LPM

    Flow Switch for liquids Datasheet

    How it works A fluid flow through the sensor causes precise displacement of a magnetic piston and closes an electrical contact (reed switch).

    Details • On/Off output; NO (SPST) working; • Detects increased or decreased flow; • Sensitivity adjustment¹.

    Typical applications • Lubrification and cooling systems monitoring; • Pipe fluid flow monitoring.

    Liquids • Clean water, oils, lubricants and filtered fuels².Liquids with magnetic particles will cause deposition/magnetic sedimentation and it will prejudice the operation of the sensor. Use magnetic filter before the sensor.Liquids with encrustation particles and/or solids require tests.

    Technical specifications

    Notes 1 In water. Set point accuracy: ±15%. Repeatability (not considering the viscosity change of liquids): ±10%.

    • Typical connection to contactor

    Mounting (Important!)

    Flow Switches and Level Switches for liquids

    flow sensor | flow switch | flow control | fluid flow controller | fluid flow indicator | flow detector | m12 connector

    The sensors work in all voltage and current ranges displayed in the table bellow:Operating Voltage Max. Switching Power Max. Switching Current Peak Current

    110Vac 20VA 0.2A 0.5A @20ms220Vac 20VA 0.1A 0.5A @20ms

    5Vdc 2.5W 0.5A 1A @20ms12Vdc 5W 0.5A 1A @20ms24Vdc 10W 0.5A 1A @20ms

    24Vac: Recommended use with Schneider coupling relay model RSLZVA1.

    G 2” Connection C.02/Apr2020

    316 Stainless Steel(PPA piston)

    Internal clearance 1000mm²Maximum operation pressure 25barOperating temperature range 0°C to 100°C | 140°C @1h

    Inlet/outlet port G 2” female (BSP - Parallel)Spring AISI 302 stainless steel

    Sealing NBR (nitrilic rubber) O’Ring³Output connection DIN 43650 Connector - B

    Enclosure rating IP66Electrical contact Reed Switch 20W/VA

    Installing the snubber filter extends the lifespan of the sensor’s electrical contact.

    K8 for ACKD for DC

    Snubber Filter

    2.8KgDimensions (mm) and Weight

    WRONG

    CORRECT

    FLO

    W

    FLOW

    Hex screw for sensitivity adjustment

    FLOW DECREASE - OFF

    FLOW INCREASE - ON Actuation Range (in LPM)Water

    From ~11 to ~145

    2 Not included with the product.

    fuels.

    Ring²

    Flow Switches for LiquidsG 1/4" Connection - FE SeriesFlow Switch FE14B02-M12Flow Switch FE14B04-M12

    G 1/4" Connection - FA SeriesFlow Switch F414B02-M12Flow Switch F414B04-M12Flow Switch F414B06-M12

    G 1/2" ConnectionFlow Switch FH12B02-M12Flow Switch FH12B04-M12Flow Switch FH12B06-M12

    G 3/4" ConnectionFlow Switch FC34B02-M12Flow Switch FC34B04-M12

    G 1" ConnectionFlow Switch FC10B02Flow Switch FC10B04

    G 1 1/2" ConnectionFlow Switch FJ112B02Flow Switch FJ112B04

    G 2" ConnectionFlow Switch FG20B02Flow Switch FG20B04