dupline hi-line irrigation control jens neigaard1

9
Jens Neigaard 1 Dupline Hi-Line Irrigation Control Dupline Hi-Line Irrigation Control

Upload: shawn-collins

Post on 17-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 1

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

Page 2: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 2

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

• Agriculture• Golf Courses• Parks, Green Areas• Gardening, Green Houses

Use of Irrigation Systems

Page 3: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 3

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

CENTRAL CONTROL

IrrigationController

VALVE

IrrigationController

IrrigationController

Page 4: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 4

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

• Reduce Irrigation Controller wiring cost and thereby-• Make individual valve control cost-effective• Increase Flexibility• More signals (flow, tamper switch)

Hi-line 2-wire com/power bus for valve control

Page 5: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 5

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

At the central location

Any Dupline Interface

• Master Module

• Master Generator

• Gateway

• GTI50

Dupline to Hi-Line Booster GH34850000

• Boosts the Dupline voltage to 28 VDC

• Connects to any Channel Generator

• Power and communication for the valves

(open valve / close valve)

Page 6: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 6

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

Valve I/O-module GH64404412

• Control of 3-wire latching valves (12 VDC)

• 2 x ”Rising Edge” triggered Outputs

(open valve / close valve)

• Built-in capacitor for energy storage to fire valve

• Built-in valve power monitoring

• 2 x Contact Inputs

• ”IP68” for underground installation

• All power from ”Hi-line”

• Built-in lightning protection

• Coding via GAP1605 (small connector)

• Also available in H4 housing (G34404412)

At the valve locations

Page 7: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 7

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

At the valve locations

Test Unit GHTU8

• Operates on Hi-Line

• Monitor and control valve operations

• Power from ”Hi-line”

Page 8: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 8

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

• Cable Specification• Min cross-section: 1.5 mm2 • Shield not required• Twist not required

• Free topology• Min. 10 s between two valve operations• Distance and number of valves

• Max 64 valves on one line• Up to 7 km distance

System Characteristics

Page 9: Dupline Hi-Line Irrigation Control Jens Neigaard1

Jens Neigaard 9

Dupline Hi-Line Irrigation ControlDupline Hi-Line Irrigation Control

1 km

2 km

3 km

4 km

5 km

6 km

7 km

1.5 mm2

64 64 64 64 64 54 44

2.5 mm2

64 64 64 64 64 64 64

12 VDC Latching Valves

Number of valves vs. distance and cable