INSTALLATION MANUAL NBDP TERMINAL DP-6 SAFET Y INSTRUCTIONS............ ............................... i 1. System Configurat ion ......................................... 1 2. Equipment Lists .................................................... 2 3. Mountin g ............................................................... 7 4. Wiring .................................................................... 9 5. Initial Sett ings ..................................................... 10 Outlin e Drawi ng .................................................... D-1 Interconnection Diagram ..................................... S-1 Schematic Diagram .............................................. S-2 R NISHINOMIYA, JAPAN

Upload: marieblue

Post on 02-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 1/26

INSTALLATION MANUAL

NBDP TERMINAL DP-6 

SAFETY INSTRUCTIONS........................................... i

1. System Configuration ......................................... 1

2. Equipment Lists.................................................... 2

3. Mounting ............................................................... 7

4. Wiring .................................................................... 9

5. Initial Settings ..................................................... 10

Outline Drawing .................................................... D-1

Interconnection Diagram ..................................... S-1

Schematic Diagram .............................................. S-2

R

NISHINOMIYA, JAPAN

Page 2: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 2/26

F I R S T E D I T I O N : M A R 1 9 9 7  D : M A Y 3 1 , 1 9 9 9

Y o u r L o c a l A g e n t / D e a l e r

9 - 5 2 , A s h i h a r a - c h o ,

N i s h i n o m i y a , J a p a n

T e l e p h o n e : 0 7 9 8 - 6 5 - 2 1 1 1

T e l e f a x : 0 7 9 8 - 6 5 - 4 2 0 0

A l l r i g h t s r e s e r v e d . Printed in Japan

P U B . N o . I M E - 5 6 1 0 0 - DD P - 6( T E N I )

c

Page 3: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 3/26

Page 4: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 4/26

ii

W RNING

Do not work inside theequipment unless totallyfamiliar with electricalcircuits.

Hazardous voltage which canshock, burn or cause seriousinjury exists inside the equip-ment.

Turn off the power at themains switchboard beforebeginning the installation.Post a sign near the switchto indicate it should not beturned on while the equip-

ment is being installed.

Fire, electrical shock orserious injury can result if thepower is left on or is appliedwhile the equipment is beinginstalled.

Ground the equipment toprevent electrical shockand mutual interference.

Confirm that the power supply voltageis compatible with the voltage ratingof the equipment.

Connection to the wrong power supplycan cause fire or equipment damage. Thevoltage rating appears on the label at therear of the display unit.

Use the correct fuse.

Use of a wrong fuse can cause fire orequipment damage.

Keep the following compass safedistances.

  UTION

Main Unit

Terminal Unit

Printer

Standard

 1.2 m

 1.4 m

 1.0 m

 Steering

 0.9 m

 1.0 m

 0.8 m

Page 5: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 5/26

1

1. System Configuration 

Main Unit

DSC

NAVAID

Terminal Unit  IB-581

Printer  PP-510

:Standard Supply:Optional Supply

24VDC

24VDC

18.0 - 36.0VDC

SSB Radio-telephone

DP-6

Page 6: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 6/26

2

2. Equipment Lists 

Standard Set

emaN epyT ytQ )gk (ssaM sk rameR

1 tinUniaM 6-PD 1 5.4

2 tinUlanimreT 185-BI 1 0.6 slairetam.tsnI / w

eeS(05110-61PC

4egap a ).

3 noitallatsnI

slairetaM

00470-50PC 1 .3egapeeS

Optional Equipment

emaN epyT )gk (ssaM sk rameR

1 retnirP 015-PP 6.3 noitallatsnI / w

egapeeS(slairetamb4 seirosseccAdna).

eeS(00100-61PF

egap 5 ).

2 reif itceR 26-RP 0.3 sniamCAroF

Page 7: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 7/26

3

Page 8: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 8/26

4

Page 9: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 9/26

54a

Page 10: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 10/26

64b

Page 11: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 11/26

75

Page 12: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 12/26

7

3. Mounting 

Mounting Guidelines

The main unit and terminal unit are designed for tabletop mounting.They may be installed almost anywhere provided the location satis-fies the following conditions:

¡The ambient temperature range is -15 to +55;.

¡For the terminal unit, select a place where the keyboard can beeasily operated while viewing the display screen.

¡Locate the units a sufficient distance from air conditioners, heatsources and ventilation fans.

¡Water splash will most assuredly harm the sensitive componentsinside the units. Keep the units away from areas subject to watersplash or water spray.

¡Select a place where vibration is minimal.

¡Leave enough space around the sides and rear of the units to per-mit checking and maintenance and to allow for circulation of cool-ing air.

¡Keep the units out of direct sunlight.

¡Keep the units away from magnetic fields (telephone, refrigerator,

compass, etc.)

Keep the following compass safedistances.

  UTION

Main Unit

Terminal UnitPrinter

Standard

 1.2 m

 1.4 m 1.0 m

Standard

 0.9 m

 1.0 m 0.8 m

Main Unit

Fix the unit with four tapping screws, referring to the outline drawingon page D-1.

Leave at least 100 mm at the sides and at least 150 mm at the rear to

permit easy checking and maintenance.

Page 13: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 13/26

8

Terminal Unit

1. Fix the hanger to the table with four tapping screws, referring tooutline drawing on page D-2.

2. Attach connectors to bottom panel. (See next page)

3. Set the terminal unit to the hanger with two knobs.4. Adjust the display screen so it can be easily viewed and tighten

knobs.

Leave at least 80 mm at the sides and rear to permit the checking andmaintenance.

Keyboard

1. Attach the four “hook loop fasteners 3” (small ones) to the bottomof the keyboard.

2. Attach the four “hook loop fasteners 4” (large ones) to the “hook loop fasteners 3” attached to the keyboard bottom.

3. Remove seals from the “hook loop fasteners 4”.

4. Set the keyboard on the mounting location and press down firmly.

Printer

Fix the printer to mounting location with two printer fixtures (sup-plied).

380 20 4-φ 6.5

Fixing holes

Mounting Fixture(2)CP16-00502

        (        9        6        )

        3        7        6

        2        8        0

        2        0        0

        4        2  .

        5

405425

Mounting Fixture(1)CP16-00501

Page 14: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 14/26

9

4. Wiring 

SSBRadiotelephone

DSC Terminal

Navigation device

*1

*1

Main Unit

Copper strapfor grounging

Ship’s Mains24VDC

Printer (option)

KeyboardTerminal Unit

*2Bottom View

24VDC

K-BOARDCOM2COM1

PRINTER

Side View

for grounding

*1 : Attach connectors in field.*2 : Attach connectors before fixing the terminal unit to the hanger.

18 - 36VDC

TECT162(NMEA)

TERMINAL

REMOTE A

REMOTE B

Ground the equipment toprevent electrical shockand mutual interference.

Confirm that the power supply voltageis compatible with the voltage ratingof the equipment.

Connection to the wrong power supplycan cause fire or equipment damage. Thevoltage rating appears on the label at the

rear of the display unit.

  UTION

Page 15: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 15/26

10

5. Initial Setting 

Answerback Code & ID Code

Enter vessel’s answerback code and ID code as follows.

NOT

The answerback and ID code number canbe written only once; be sure to enter thecodes correctly.

Answerback Code

 Procedure

1. Press function key F5 and then the [5] key. The display shouldlook something like below.

Answerback Code

Answerback Code Entry

 Answerback Code Entry Screen

2. Enter vessel’s answerback code (max. 20 characters, includingspaces). Press the ENTER key. The prompt OK/CANCEL asksfor verification of data. If correct, press the ENTER key again.

Example

Answerback Code

123456789 FURU X

Answerback Code Entry

 O K

Cancel

 Caution

Confirm the 'CODE' before pressing ENTER key.

You cannot change the CODE once it has been entered.

 Message for confirmation of code entered 

Page 16: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 16/26

11

3. For final verification of the data, the above CAUTION appears. If correct, press the ENTER key again.

NOTE: Form of answerback depends on coast statiton. Some re-quest ship name and/or callsingn.

ID Code

Procedure

1. Press function key F5  and then the [6], [7], [8] or [9] key to enterthe Group ID Code (4 or 5 digits), Group ID Code (9 digits), Se-lect ID Code (4/5 digits) or Select ID Code (9 digits), respectively.

Group ID Code (4 or 5)

Group ID Entry

 ID Code Screen

2. Enter group ID or select ID. Then, press the ENTER key. A promptasks for verification of data. If correct, press the ENTER key.

Example

Group ID Code (4 or

12345

Group ID Entry

 O K

Cancel

 Caution

Confirm the 'CODE' before pressing ENTER key.

You cannot change the CODE once it has been entered.

 Message for confirmation of code entered 

3. For final verification of the data, the above CAUTION appears. If correct, press the ENTER key again.

Note: Application software of DP-6 is already installed in the unit.The floppy disk programed in the accessores is for backup.

Page 17: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 17/26

12

System Settings

Press function key F6 to display the System screen.

Setup ock  Change Default

*Slave Delay 5 msec (0- 50 msec)*BK Timing PreTone 10 msec (0-100 msec)

  PoseTone 0 msec (0- 20 msec)

*Mute Timing PreBK 0 msec (0- 20 msec)

  PostBK 0 msec (0- 20 msec)

*Modem Output Level 0 dBm (-30 - +10 dBm)

MIF Tune OFF O N

  Freeze OFF O N

  AGC OFF O N

  Emission OFF O N

TX/RX MSG Save OFF O NEdit Before sending OFF O N

Time system OFF UTC SMT JST

Time & Data 1997/3/16/ 10;00;00

Display Mode Normal Reverse

Self Test

System

Procedure

To change settings, press the [ ] key to display change (on the Setupline) in inverse video. Press the [ ] key to select item, then press the[ ] or [ ] key to select option.

(“Default” on the Setup line is for factory use.)

Menu Description

Setup Lock/unlocks settings.

Slave Delay Sets the length of the slave delay timing inthe ARQ mode, between 0 - 50 msec.

BK Timing Pre Tone Sets the timing for the leading edge of theBK signal in the ARQ mode.

  Post Tone Sets the timing for the trailing edge of theBK signal.

Mute Timing Pre BK Sets the timing for the leading edge of themute signal in the ARQ mode.

Page 18: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 18/26

13

  Post BK Sets the timing for the trailing edge of themute signal.

NOTE: For further details about BK timing and mute timing, see page 14.

Modem Output Level Adjusts output signal from the modem, be-

tween -30 and +10 dBm. Refer to operation’smanual of radiotelephone connected. WithFURUNO radiotelephone, the default set-ting is available.

MIF Command

  Tune* With FURUNO transmitter connected, ONsends antenna coupler tuning command.

  Freeze* With FURUNO radio equipment connected,ON sends “freeze” command to disable con-trols of radio equipment.

  AGC* Turn on for radio equipment which supportsAGC command in the MIF format, so thatthe gain is automatically controlled in thetelex mode.

  Emission* ON sends EM (emission) command to ra-diotelephone.

TX/RX MSG Save An outgoing or incoming message can besaved automatically to a floppy disk.

Edit before Sending OFF: Transmits keying operation one byone.

ON: Transmits message only when theENTER key is pressed.

*: These commands are available according to a model connected.

Page 19: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 19/26

14

INFORMATION RECEIVING STATION TMING

RX MUTE Signalto Transceiver

TX KEY Signalto Transceiver

SignalSequence

RX ON

MUTE ON

TX available

BK OFF BK OFF

RX ON

MUTE OFF

21

BK ON

TX3   4

5

Reception of3 characters

ACK Singal

End of RX Beginning of TX

Reception of3 characters

RX OFF

MUTE OFF

5 : SLAVE DELAY3 : BK TIMING PRE TONE4 : BK TIMING POST TONE1 : MUTE TIMING PRE BK2 : MUTE TIMING POST BK

Timing values depend on the transceiver connected. Therefore sometrial and error may be necessary to find suitable values.

Default values are for FURUNO SSB Radiotelephone model FS-1500or FS-1562.

Setting of Timing

Timing (msec)

FS-5000 series

FS-8000 seriesFS-1562

FS-1500 series

FS-1502FS-1552

RC-258

RC-508RC-808RC-1208

Slave DelayBK Timing Pretone  Post ToneMUTE Timing Pre BK  Post BK

5 msec10 msec0 msec0 msec0 msec

50501000

55000

DP-6MIF AGC

System settingof eachequipment

Remarks

ON(FS-1562 : OFF)

9982  / 1(FS-5000/8000)

OFF

9934  / 1 (FS-1502)

9904  / 09905  / 19906  / 10ms

(FS-1552)

OFF

none

Page 20: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 20/26

Page 21: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 21/26

Page 22: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 22/26

Page 23: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 23/26

Page 24: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 24/26

Page 25: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 25/26

Page 26: DP6 Installation Manual Version D

8/10/2019 DP6 Installation Manual Version D

http://slidepdf.com/reader/full/dp6-installation-manual-version-d 26/26