Transcript
Page 1: Trafo/ Transformator

MineraOil-immersed Distribution andMed i u m Power Tra nsformers

g

*&*"To ensu re' ryi$xi m u m av€ila bi I ity oequipments of the highest qual

We offer you a conrplete range of oil-immersed distribution and medium power transformers adapted tothe structure of your distribution network and suited to standard and special applications.

Our Large industrial woddwide platform provides a full range of produts at ourcustomer's doorstep ensuring a shorter delivery time

electiical

Customer benefits. High quality and realibility. Economically optimized. Capitalization of losses. Reduced dimensions. Solid construction. Long life-cycle. Low maintenance. Eco-friendly solution

s'F#.4:r

Ouality based on years of experienceWith more than 40 years of technical expeftise and over two millionoil-immersed transformers installed worldwide, we constantly designand improve the Minera transformer range to ensure optimumreliabillty and safety of your installations while offering the mostcost-effective solution. You are sure to invest in a proven technologyconstantly enhanced in our competence centers.

Our standard range of Minera transformers is available as:. Three phase units (single phase available on request). With ratings up to 20 MVA, 72.skV, 50/60 Nz

(Higher ratings available on request). Naturally cooled (ONAN) or air-forced (ONAfl upon request

We also offer transformers for special applications (rectifier, Oil & Gas Zone ll,earthing, welding,transformers with OLIC, reactors, etc.)

Minera oil-immersed transformers meet the requirements of internationalstandards such as ANSI, lEC, SPLN and individual country standards.

ScbneiderilFEl ectric

Page 2: Trafo/ Transformator

Minera, the right tunefor your network

Depending on the application andenvironmental influences, you might require adifferent type of oil-immersed transformer.Minera can deliver the flexibility you require:

. Breathing type with conservator, hermeticallysealed or nitrogen gas cushion sealed type

. For indoor applications: in buildings orindustrial plants, or in compact distributionsubstations

. For Outdoor applications: ground mountedbut also pad or pole mounted

. Low noise levels for urban or residentialareas

. Normal, low or very low level of losses toenhance the distribution network effrciency

. Vegetable Oil available on request

High quality levelfor more reliability

As a customer satisfaction is our main concern, we constantlyimprove our manufacturing processes, We have reduced our deliverytimes while ensuring a high quality level. All of our Mineraoil-immersed transformer production sites are ISO 9001 or ISO 14001and OHSAS 18001 certified.

To ensure this high level of quality, our Minera transformers undergoroutine tests in accordance with IEC standards. We can also proceedto type test or special tests on request.

Our company follows a policy of continuous improvement takinginto account the latest worldwide developments. This ensures thattransformers are state-of-the-art and comply fully with the moststrict requirements: fast delivery time, improved quality and recyclingcapabilities, reduced size and, on request, very low noise and verylow losses.

Page 3: Trafo/ Transformator

$-ii

i

i

I

i

ip.. - _.-_'---:

"@@)!@&

Highest systemvoltage (HV)

Rated power Dimension (mm) Weight (kg)

400 1 460 860 1457 670 670 1280 aatr

500 1660 970 1512 670 670 1 530 380630 1660 1020 1557 670 670 1760 475

<- 24 kY 800 1700 1020 1657 670 670 2100 5401 0001250

1800 1090 1737 820 A20 2350 6001 BBO 1 130 1787 1 070 1070 3020 750

1 600 2000 1170 1 845 1 070 1 070 3520 9252000 2300 1370 1 845 1 070 1 070 4395 1 155'/51 ll I

I 30002340 1 370 2045 1 070 1 070 5390 1 3302580 1 530 2188 '1070 1070 6300 1670

31 50 2580 I OJU 21 88 1 070 1 070 631 0 1670

Highest systemvoltage (HV) Rated power Dimension (mm) Weight (kg)

800 470 1 195 450 450 485 16050 '1040 628 1234 450 450 490 180

<= 24 kV 100 1 150 667 1341 520 520 715 '190

I btJ 1340 640 1356 520 520 1025 265200 1290 670 1 446 520 520 1 050 220250 1325 680 1 461 520 520 1 150 230

4OO

1250 860 '1679 520 520 1470 3001250 860 1679 670 670 1520 290

630 1 830 1 040 17aO 670 670 2215 530'1000

1 9BO 11 40 1899 820 A20 31 55 lzo

IKPP, Serang - lndonesia Thamrin City, Shopping Centre and Apartement,Jakarta - lndonesia

Page 4: Trafo/ Transformator

MineraOil lmmersed Distribution andMedium Power Transformers

Oil lmmersed Distributionand Medium Power Transformer Hermetically sealed, conservator type or Nz Gas Cushion Type

Rated power 25 - 2O.OOO kVA (higher rating available on request)

lnsulation levels According to IEC Urrr = 1.1 ,3.6,7.2, 12, 17.5,24,36,72kVAccording to ANSI up to 69 kV (higher ratings available on request)

Phases 3-phase (single phase is available on request)

Tappings x 2.5/o or + 2x2.5% (or different ranges on request)

Short circuit impedanceUk=4% Ior P < 630 kVA and Uv < 24 Kt/tJk=4 or 45% for P < 630 kVA and UHr = 36 kVUk-6/. or above for P > 630 kVADifference value aiso available on request

Rated frequency 50 Hz (60 Hz on request)

Vector groups

Yzn recommended up to 50 kVA with Ura <24KvYzn recommended up to 100 kVA with Uv = 36 kVDyn for all oiher rated power (any vector group according tolEC, ANSI, and other international Standards)Dyn for all other rate power (any other vector groupaccording to lEC, ANSI, and other international Standards)

Material thermal class insulation According to IEC 60085 class A

Temperature rise Mean winding temperature rise : 65 KTop oil temperature rise : 60 KWith ambient temperature in accordance with IEC 60076-iThe temperature of the cooling air should not exceed:. 20'C yearly averageo 3OoC monthly average of the hottest month. 40oC at any time

For other ambient temperatures, winding and oiltemperature rise should be adapted

Type of cooling ONAN (Oil Natural Air Natural) or ONAF on request

Dielectric liquid Mineral oil according to IEC or ANSI standardOn request : silicon, midel, vegetable oil

Ability to windstandShort-circuit

The transformers are designed to withstand the thermal and the dynamic effectsresulting from a secondary shortcurcuit in accordance with IEC 60076-b

Sound levelThe measurement (A-weighted sound pressure LpA) and thecalculation of sound level(A-weighted sound level LwA)are done in accordance with IEC 60076 10. The sound levelrequirements are in accordance with national standards,

lnstallations lndoor or outdoor

HV & LV terminals HV terminals : plug-in or porcelain bushingsLV terminals : busbars or porcelain bushingsOn request : cable boxes accord ng to clienVmanufacturerstandard or norm (i,e BS requirements )On request : protective boots for HV/LV

Accessories

. Standard : lifting lugs, earlhing terminal, name and rating plate, oil filting plug,off circuit tap changer, bidirectional rollers if applicable (out of scope hangingpole transformer)

. On request : pad lock/locking device for HV plug-in bushings and /ortap changer, protective relay (DGPT2, RlS, DMCR,...), oil level indicator,thermometer, with or without contacts, pressure relief device, pressurerelay with contact, oil drain plug with/without sampling device, filling valve,drain valve, explosion vent, winding temperature indicator (OTi + WTI)Accessories for conservator : dehydrating breathing Buncholz relay,drain plug, oil level indicator.

PT. Schneider lndonesiaJl. Swadaya PLN - KlenderJakarra l3930 INDONEStAPh. +62(O)21 2926 58OO (Hunting)www.schneider-electric.co.id

Fax. +62 (O)21 29265401 (General)+62 (O)21 460 4179 (Distribution)+62 (O)21 460 6159 (Switchgear)

SESA101910
Rectangle