![Page 1: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/1.jpg)
SSMS MS CControl and ontrol and MMonitoring onitoring SSystem ystem IIn n
CChicken hicken FFarmarm
Prepared ByPrepared By: : MMaysoon aysoon MMohannaohanna
EEman man MMadiadiSupervisorSupervisor: :
DDr. r. JJamal amal KKharoushehharousheh
20092009
![Page 2: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/2.jpg)
CContentontentToday we will talk about :Today we will talk about :
1.Project idea and over view.2. Where we can use it.3.What we need to know.4. AT Commands Test .5.Project flow chart.6.Temperature and IR Sensors.7. Problems.
![Page 3: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/3.jpg)
PProject roject IIdeadea The goal of this project to monitor and control a
chicken farm by SMS from far place , two part is used:
one is serial port with mobile & temperature sensor & infra red sensor that sense the change in degree in the farm & any unfamiliar movement ,this part called (sensing part) .
Two is simply mobile you can receive messages from first part and send command messages to it this part called( controlling part).
![Page 4: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/4.jpg)
BBasic asic OOver ver VViewiew
![Page 5: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/5.jpg)
OObjectivesbjectives
1- our project aims to allow owners to monitor and control their farms or houses devices from far places.
2- allow owners to control their farms or houses by cheap cost.
WWhere here WWe e CCan an UUse se TThis his PProjectroject??
1- We can use this project in any place need to be controlled and monitored , such as your home, company ,farms , …….
2- In our case we choose the chicken farm to control and monitor it.
![Page 6: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/6.jpg)
WWhat hat WWe e MMust ust KKnownow ??
To get started doing our project several points are to be determined:
1 -GSM network 2 -Type of mobile useable
3 -Sensors behavior a- temperature sensor
b- infrared sensor
![Page 7: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/7.jpg)
AAT T TTestest
The mobile phone ( Nokia 6070 ) and it is serial we used
![Page 8: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/8.jpg)
AAT T CCommands ommands WWhich hich WWe e UUsedsed
![Page 9: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/9.jpg)
TTo o PPerform erform TTestestTo use HyperTerminal to send SMS to your mobile phone using AT commands we follow the procedure below:
1.Connect your mobile phone to a computer by using a serial cable.
2. Run HyperTerminal by selecting Start -> Programs -> Accessories -> Communications -> HyperTerminal.
![Page 10: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/10.jpg)
3. In the Connection Description dialog box enter a name and choose an icon you like for the connection. Then click the OK button.
![Page 11: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/11.jpg)
4. In the Connect To dialog box, choose the COM port that your mobile phone is connecting to in the Connect using combo box. Then click the OK button.
![Page 12: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/12.jpg)
5. The Properties dialog box comes out. Enter the correct port settings for your mobile phone. Then click the OK button.
![Page 13: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/13.jpg)
6. Then go to file > properties>setting >ASCII setup> echo typed characters locally then click the ok button.
![Page 14: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/14.jpg)
Settings
![Page 15: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/15.jpg)
ASCII setup
![Page 16: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/16.jpg)
AT Response
![Page 17: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/17.jpg)
Sending SMS
![Page 18: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/18.jpg)
Receiving SMS
![Page 19: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/19.jpg)
Reading Message
![Page 20: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/20.jpg)
PProject roject SSchematicchematic
![Page 21: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/21.jpg)
PProject roject CCircuitircuit
![Page 22: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/22.jpg)
PProject roject FFlow low CCharthart
![Page 23: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/23.jpg)
PPrecision recision TTemperature emperature SSensorensor
The LM335 are precision temperature sensors which can be calibrated. They operate as a 2-terminal Zener and the breakdown voltage is directly proportional
to the absolute temperature at 10mV/K .
![Page 24: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/24.jpg)
WWhy hy LM335LM335 ? ?
1. Easy to calibrate.2. Simple to implement.3. Has large current range from 450μA to 5 mA.4. Have a typical error of less than 1Cº over a
100Cº temperature range.
![Page 25: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/25.jpg)
TTemperature emperature SSensor ensor ccctct
The practical calibrationThe practical calibration
At 20 c° the output voltage = 2.5 V.At 30 c° the output voltage = 3.5 V.
![Page 26: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/26.jpg)
RRing ing CCircuitircuit
![Page 27: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/27.jpg)
PProblemsroblems1. It is difficult to choose the kind of
temperature sensor & to find it is correct cct that we will use it to calibrate it .
2. 2. The connection between microcontroller (PIC) and mobile phone .
3. Programming the microcontroller (PIC).
IImprovementsmprovements1. 2.
![Page 28: S MS C ontrol and M onitoring S ystem I n C hicken F arm](https://reader036.vdocuments.mx/reader036/viewer/2022070402/5681379c550346895d9f3f8d/html5/thumbnails/28.jpg)
Thanks for listening .Thanks for listening .Especial Thanks for every one help us. Especial Thanks for every one help us.
GGame ame OOverver