GENERAL ELECTRICAL NOTES
7. NO ALUMINUM CONDUIT OR CONDUCTORS WILL BE ACCEPTED.
6. ALL DEVICE COVER PLATES TO BE 305 STAINLESS STEEL.
4. CEILING
(B) CONTRACTOR TO MAKE FINAL CONNECTIONS OF CONDUCTORS.
3. CONTROLS
1. WALK-IN FREEZERS AND COOLERS
PROVIDE AND INSTALL A SUITABLE LENGTH OF S.T.O. CORD FROM EACH
PRE-WIRED JUNCTION BOX OF EVAPORATOR COIL, TO POWER RECEPTACLE
CORD TO BE EQUIPPED WITH A HUBBLE #7311 CAP AND SUITABLE FOR
CONNECTION TO A #7310 RECEPTACLE.
(A) CONTRACTOR TO PROVIDE AND INSTALL ALL CONDUIT AND
CONDUCTORS FROM THERMOSTATS, FIRESTAT, HUMIDSTAT AS
SHOWN ON DRAWINGS.
CONTRACTOR TO REFER TO REFLECTED CEILING PLAN FOR EXACT
LOCATION OF LIGHTING FIXTURES, AIR CONDITIONING DIFFUSERS,
SPRINKLER SYSTEM, ETC.
8. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY PUBLIX AND
INSTALLED AND WIRED BY CONTRACTOR.
11. EMERGENCY GENERATOR
10. FIRE ALARM
(A) CONTRACTOR TO INSTALL AND CONNECT AUTOMATIC TRANSFER
9. ALL SUPPLY AND EXHAUST FANS TO BE FURNISHED AND INSTALLED BY OTHERS
WIRED AND CONNECTED BY ELECTRICAL CONTRACTOR
12. DO NOT USE MACHINE ROOM ROOF STRUCTURE FOR SUPPORTING OF ANY
ELECTRICAL EQUIPMENT, SUCH AS CONDUIT OR LIGHTING FIXTURES, USE
UNI-STRUT WELDED TO OR CONNECTED TO BEAMS.
14. ALL CONDUIT ROUTING SHOWN SOLID TO BE FED CONCEALED ABOVE
CEILING. ALL CONDUIT ROUTING SHOWN WITH DASH LINES TO BE
CONCEALED WITHIN WALLS OR BENEATH SLAB.
(C) FIRE ALARM SYSTEM SHALL MEET ALL LOCAL REQUIREMENTS,
NFPA NO. 72. AND ADA.
13. CONTRACTOR TO PROVIDE PULL CORD IN ALL EMPTY CONDUITS, (ELECTRICAL.
TELEPHONE, COMMUNICATIONS, ETC.) FOR FUTURE USE, TERMINATE CORD
WITH SUITABLE SIZE WASHER TO PREVENT SLIPPAGE AND PROVIDE BLANK
COVERS FOR ALL BOXES NOT USED. ALL CONUITS TO HAVE BUSHINGS TO
PREVENT CABLING DAMAGE.
15. ALL CIRCUITS TO INCLUDE EQUIPMENT GROUND CONDUCTOR SIZED PER
ARTICLE 250 OF 1999 NFPA 70. ISOLATED GROUND CONDUCTOR (WHERE
REQUIRED). ISOLATED GROUNDCONDUCTOR(IG) TO BE GREEN WITH YELLOW STRIP.
(B) ALL FIRE ALARM EQUIPMENT WILL BE FURNISHED, INSTALLED AND
CONNECTED BY FIRE ALARM CONTRACTOR.
2. NOT USED
5. NOT USED
(A) INSTALL ALL CONDUIT AND OUTLET BOXES AS SHOWN ON FIRE ALARM
DRAWING.
SWITCHES AS FURNISHED BY PUBLIX AND INDICATED ON PLANS.
(B) GENERATOR TRANSFER SWITCH ARE TO BE INSTALLED IN LOCATION
AS SHOWN ON DRAWINGS AND TO MEET ALL LOCAL AND NATIONAL CODES.
N.T.S.
TYP. POWER POLE
INSTALLATION DETAIL
UNSWITCHED
POWER TRACK
(CASE POWER)
TYP. POWER BOX SUPPLIED
WITH POWER GRID - INSTALLED
BY CONTRACTOR
POWER GRID SUPPORT
(INSTALL NO MORE THAN
8 FOOT ON CENTER)
EXISTING LITELAB
CRISS-CROSS
BRACKET
N.T.S.
4PARALLEL BUSRUN TRACK
POWER POLE COVER WITH
RECEPTACLE KNOCKOUTS
TO BE MTD. ON FRONT OF
POLE - OPPOSITE POWER
CONDUCTOR COMPARTMENT
COMMUNICATION/DATA
COMPARTMENT FOR
SCALE CABLE
SECURE POWER
POLE TO FLOOR
AND CAULK WITH
SILICON TO FLOOR
LAY-IN
CEILING (TYP.)
CONTRACTOR TO SECURE POWER
POLE AS PER MANUFACTURERS
RECOMMENDATIONS
COMMUNICATION CONDUIT
(MIN. SIZE AS INDICATED
ON E-6 & CONDUCTORS
AS INDICATED ON DWG. E-6
FLEX CONDUIT TO
POWER POLE
CONTRACTOR TO INSTALL CONDUCTORS
AS INDICATED ON E-03 THRU FACTORY
SUPPLIED J-BOX TO RESPECTIVE PANEL
IN 1"C (MAX.). CONDUIT QTY. MAY VARY.
CONTRACTOR TO MOUNT J-BOX AT TOP
OF POWER POLE.
CONTRACTOR TO PROVIDE & INSTALL DIVIDED
POWER POLE (WIREMOLD #PUBNP600-12-8X (12’-8")
OR #PUBNP600-15-2X (15’-2") ) & RECEPT.S AS
INDICATED ON DWG. E-03 (KNOCK OUTS PROVIDED).
COORD. EXACT LOCATION OF POLES WITH PUBLIX REP.
PRIOR TO FINAL INSTALL - ALL POLES ARE TO BE
INSTALLED SO PLUGS ARE PARALLEL WITH TO REAR OF
CASE OR SERVICE LINE-UP.
CALL WES TURNIPSEED AT UNITED ELECTRICAL
SALES (888 475 1326) FOR ORDER ASSISTANCE
IF NEEDED.
SWITCHED LIGHTING
TRACK (ACCENT LIGHTING)
BLANK POWER POLE COVER
TO BE INSTALLED ON BACK
OF POLE TO CLOSE OFF
POWER CONDUCTOR
COMPARTMENT
POWER CONDUCTORS TO BE
RUN IN POWER CONDUCTOR
COMPARTMENT AND BROUGHT
THROUGH POWER POLE SPINE
TO MAKE CONNECTION TO
RECEPTACLES AS REQUIRED
BOLTED TO JOIST
CONNECTOR
EXISTING STEEL JOIST
AND ROOF DECK
VARIES
6"
VA
RIE
S
CL
2N.T.S
TYP. E.D.F RECEPTACLE
MOUNTING DETAIL N.T.S
TYP. PENDANT
HUNG RECEPTACLE
CORD & RECEPT. ASSEMBLY
(SEE SYMBOL SCHEDULE)
RECEPT. @ +3’-0"
STRAIN
RELIEF
RIGID NIPPLE
AND COUPLING
CADDY CLIP
CLG. TEE
CLG. BD.
4" x 4" J-BOXTYP. ELECTRIC WATER COOLER
(E.D.F.) SUPPLIED BY OTHERS
TYP. RECEPTACLE LOCATION
(ELEC. CONTRACTOR TO VERIFY
ALL DIMENSIONS AND COORDINATE
WITH PLUMBING CONTRACTOR)
3
1
AREAS OF HORIZONTAL RUNS BY TRADES
ELECTRICAL: TOP OF STEEL GIRDER AND JOIST TO 32 IN. BELOW TOP OF STEEL;
WHERE EXPOSED IN THIS PROTOTYPE, IMMEDIATELY BENEATH TOP
OF JOIST MEMBER AND PASSING BETWEEN STEEL JOIST WEBBING.
(THE INSTALLATION SHALL BE IN COMPLIANCE WITH NEC 300.4(E))
REFRIGERATION: 32 IN. TO 36 IN. BELOW TOP OF STEEL GIRDER OR JOIST; WHERE
EXPOSED IN THIS PROTOTYPE, IMMEDIATELY BELOW BOTTOM CHORD
OF STEEL JOIST GIRDERS AND JOISTS.
FIRE SPRINKLER: 8 IN. ABOVE CEILING; WHERE EXPOSED IN THIS PROTOTYPE,
8 IN. ABOVE BOTTOM CHORD OF STEEL GIRDER JOISTS AND JOISTS.
AIR CONDITIONING: 36 IN. BELOW ROOF DECK TO 10 IN. ABOVE CEILING; WHERE
EXPOSED IN THIS PROTOTYPE, HANG AS CLOSE UNDER BOTTOM
CHORD OF STEEL JOIST GIRDERS AND JOISTS AS POSSIBLE
WHILE LEAVING ROOM FOR REFRIGERATION LINES.
IF DEVIATION FROM THESE AREAS IS INDICATED, SUCH DEVIATION
MUST BE AGREED UPON BY JOB SUPERINTENDENT AND PUBLIX
REPRESENTATIVE.
E08.01
E08_01
17
SECTION ’A’ SECTION ’B’
MICROWAVE
OPENSPACE
SINK & REFRIG. CABINET
SECTION ’A’
SECTION ’B’
DEMO ISLAND ELEVATION
1’-
6"
APRON’S KIOSK KEY PLAN
F APRON’S KIOSK - DEMO ISLAND G APRON’S KIOSK - SINK & REFRIG CABINET
10:12
9
A
B
G
F
AB
1313
13
19
5SCALE: 12"=1’-0"
APRON’S KIOSK (F & G)
L1420
SPLIT
21,23
4"
4"
2�"
DEMO ISLAND
CONTRACTOR SHALL
DRILL 1�" HOLE IN
SIDE OF CABINET AS
INDICATED
CONTRACTOR SHALL DRILL
1�" HOLE IN SIDE OF MILWORK
WHERE INDICATED. PROVIDE 1�"
HOLE IN POWER POLE AT
RESPECTIVE LOCATION
20A RATED
TOGGLE SWITCH
20A RATED
GFI RECEPT.
WIREMOLD SERIES
AMTC-4 ALUM. POWER
POLE
CONTRACTOR TO INSTALL 20A
DUPLEX RECEPT.S IN MILLWORK
(OPENINGS PROVIDED) GFI
WIREMOLD SERIES
AMTC-4 ALUM. POWER
POLE. SECURE FLUSH
TO MILLWORK
RUN 4#10; 1#10(EG) IN �" FMC DOWN INSIDE
WIREMOLD SERIES AMTC-4 ALUM. POWER
POLE. ROUTE FMC THROUGH 1�" HOLE IN
MILWORK TO RECEPT.s. - SECURE POWER POLE
FLUSH TO MILLWORK, FLOOR, AND STRUCTURE.
CONTRACTOR TO INSTALL 20A
GFI DUPLEX RECEPT.S AND
TOGGLE SWITCHIN MILLWORK
(OPENINGS PROVIDED)
DES
CRIP
TIO
ND
ATE
MA
RK
DES
CRIP
TIO
ND
ATE
MA
RK
RE
VISIO
NS:
PROFESSIONAL SEAL:
1 2 3 4 5 6 7 8 9
A / E OF RECORD:
HECTOR E. VAZQUEZ
FLORIDA P.E. NO. 66804
SHEET INFORMATION:
JOB NO.:
CHECKED BY:
QC REVIEW:
ORIGINAL DATE: 10/20/17
SHEET TITLE:
NOT VALID FOR CONSTRUCTION
UNLESS SIGNED IN THIS BOX
100056077
SHEET NUMBER:
SHEET: OF
ST
OR
E N
o. 0032 (IN
TE
RIO
R R
EM
OD
EL)
PR
OJE
CT N
AM
E:
CLIE
NT:
FB
PE C
OA N
o.: 2
4C
OA N
o.: A
A000723
2001 N
W 1
07T
H A
VE.
MIA
MI, F
LO
RID
A 33172-2
507
TE
L: 305.5
92.7
275
CO
RP
OR
ATE
OFFIC
ES,
AR
CHIT
EC
TU
RE
DEPT.
BO
X 407, LA
KELA
ND, FL 33802
TELEP
HO
NE (9
41)688-11
88
10
11
13
14
15
16
17
18
12
21 3 4 5
54321
A
B
C
D
E
A
B
C
D
EDESIGNED/DRAWN BY:
H.V.
H.S.
08-ELEC\ 06-ELEC\ 0032-
44
RM
OD
EL:
FILE\PATH\NAME: G:\BLDGSVCS\COMMON\Publix Supermarkets\ 01-Projects\ 01-Remodels\ 0032-2017_100056077\ I. Production\ 01-Workset\ 05.Bentley\
12
SH
OPP
ES A
T H
AM
MO
CK C
OV
E
4370 T
HO
MASS
ON D
R
NAP
LES, FL 3
4112-6
725
H.V./O.R.
Reviewed for CodeCompliance
PRBD20171042446