Compact IntegratedDistribution Substation(CIDS)
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
2/12
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
3/12
2
SAVE SPACE
2.5m2 footprint for CIDS up to 630kVA.
SAVE THE ENVIRONMENT
No SF6, No PCB.
SAVE MONEY
Save up to 50% from conventional package substation with housing.
ENSURE SAFETY FOR PUBLIC
No exposed live parts.
ENSURE SAFETY FROM FIREIf filled with flame retardant fluid.
1- INTRODUCTION
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
4/12
3
2- DESCRIPTION
The CIDS is a compact fully integrated outdoor package substation with medium
voltage equipment, transformer, and low voltage equipment. The package
substation is completely manufactured and assembled ready for installation on site.
It ensures a high level of protection against access to live parts with a protection
degree of IP 54 according to IEC 60529.
The operation and control is achieved from the front of the unit, with separate
compartments for medium voltage and low voltage sections. Four lifting lugs
located on the upper part enable the lifting of the complete unit easily.
2.1. Major Benefits
2.1.1. Compact design-Reduced footprint Reduction of space requirement. Reduction of footprint.
2.1.2. Cost Savings Minimum installation and maintenance labor costs.
Minimum civil work; no building or vault structure.
No need for main low voltage circuit breaker.
2.1.3. Operational Integrity Components are assembled and tested as an integral unit at the factory.
Access to all elements of control and protection in one casing.
2.1.4. Safety Live parts inside the secure enclosure are hidden from the public and
environment. If filled with flame retardant fluid, risk of transformer fire is greatly reduced due to
high fire and flash points.
2.1.5. Environmental Integrity Low profile design requires minimum real estate.
Dielectric fluid replaces ozone-depleting SF6 gas, currently used in RMU switching
modules.
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
5/12
4
2.2. Main Components
2.2.1. Enclosure
Single compact enclosure housing the transformer, medium voltage and low voltage
sections.
The is designed to be installed outdoor, with a protection degree of IP 54 according
to IEC 60529
2.2.2. Low voltage sectionThis section can be designed and manufactured according to the needs of each
customer. Basic equipment includes:
Low voltage bushings
Three current transformers
Four outgoing circuits by fuse links
Three ammeters
One voltmeter + one selector switchOptional:
Circuit breakers instead of fuse links
Multifunction electronic meter
2.2.3. Medium voltage sectionIt includes the following components:
Plug-in bushings
Two sectionalizing switches for incoming and outgoing lines with earthling facility
Main interrupter for protection against overloads and secondary short circuits
Backup fuses for protection against internal faults
Tap changer for voltage control (off-load)
Voltage presence indicators
Hotstick for sectionalizing switch operationOptional:
Earth fault and short circuit indicators
2.2.4. Transformer sectionIt includes the core and the windings of the transformer.
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
6/12
5
Plug-in bushing (Fig 1)
Built in capacitive point for voltage presence detection.
Three phase loadbreak sectionalizing switch (Fig 2)Make-Before-Break operation.
Silver plated copper contacts.
Open/Close/Earth positions.
Back-Up current limiting fuse(Fig 3)
For transformer internal faults.
Protects and isolates faulty equipment.
Coordinated with main interrupter (4), gives full range of fault protection.
Main interrupter (Fig 4)
Current and temperature sensitive protective device.
Protects from overloads and secondary faults.
Three phase trip, externally resettable.
Insulating fluidStandard mineral PCB free oil according to IEC 60296.
Optional: fire resistant high fire point organic or synthetic fluid.
Fig 1 Plug-in bushing Fig 4 Main interrupter Fig 2 Three phase load break
sectionalizing switch
Fig 3 Back-up current limiting
fuse
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
7/12
6
2.3. CIDS Single Line Diagram
Earth
Earth
B
Source
LV
Panel
Closed
A
Source
2Closed
1
5Open
LV
Open
3 4 TransformerCoil
Fig 5 Lifting Lugs Fig 8 Three phase main
interrupter
Fig 6 Name Plate +
single line diagramFig 7 Mimic and labels
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
8/12
7
Design ambient temperature 40C
Frequency 50Hz or 60Hz
2.4. Technical Data
Rated voltages
Primary highest voltage 12kV /17.5kV/24kV
Rated secondary voltage From 231V up to 433V
Vector group Dyn11
Lightning impulse voltage (primary) 75kV/95kV/125kV
Industrial frequency withstand during 1 min (primary) 28kV/38kV/50kV
Off load tap changer (5 positions) 2x2.5%
No load losses 445W 840W 920WLoad losses 2715W 3950W 6020W
Short circuit impedance 4.00% 4.00% 4.00%
ACCORDING TO IEC 60076 STANDARD
Rated short duration admissible current 16kA
Sectionalizing switch for input-output and ground
Highest voltage level 12kV /17.5kV/24kV
Rated direct current 630A for 12kV primary
400A for 17.5kV and 24kV primary
Fuses
Highest voltage level 24kV
Maximum interrupting current 50kA rms
Plug-in bushings, 6 in loop
Highest voltage level 24kV
Rated direct current 630A
ACCORDING TO IEC 60298 STANDARD
Rated voltage From 231V up to 433V
Rated current Up to 1000A (according to transformer rating)
Short time current (1s) 25kA
Earthing Neutral solidly earthed
Industrial frequency withstand during 1 min 2.5kV
Lightning impulse withstand test 6kV
ACCORDING TO IEC 60439 STANDARD
GENERAL
TRANSFORMER 250kVA 400kVA 630kVA
MEDIUM VOLTAGE
LOW VOLTAGE
For 1000kVA please consult us
For other requirements than the above table, please consult us
Fig 9 Off load tap changer Fig 13 Dielectric
level indicator
Fig 10 LV porcelain
bushings
Fig 12 Pressure
relief valve
Fig 11 Medium voltage
screened bushings
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
9/12
8
2.5. Dimensions and Weights
D
G
L1
H
A
C
L2
BF
Ma d e in Lebanon
MATELEC s.a.l
B 2 C 1 C 2
nc
MagneX
Fuse
Sectional izingSw itch
A
BC
ab
c
A 1 A 2 B 1
ba
Email:matelec@matelecgroup. comP. O . Box :12 J bei l -Lebanon
Fax:+9619620934/35
Manuf acturedby Matelec s.a. l
Tel :+9619 620920
E
Rating
kVA
-C-
mm
-D-
mm
-E-
mm
-F-
mm
-G-
mm
-H-
mm
250
400630
1230
12301230
2080
20802080
1230
12301230
1975
19751975
715
715715
1117
11171117
813
813813
2550
29003250
Dimensions and weights are approximate and may change according to specifications.
850
850850
Total
Weight
Kg
-B-
mm
-A-
mm
Fig 14 Line Sectionalizing
switch and earth controlsFig 16 Elbow ConnectorFig 15 Led ( voltage indicator) Fig 17 Grounding terminals
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
10/12
9
21
18
18
19
20
15
16
17
11
12
13
14
A2
L1
MadeinLebanonMATELECs.a.lABCabc
A1
a
L2
C2MagneXFuse
Email:[email protected]: 12 Jbeil-LebanonManufactured byMatelecs.a.lB2C1
nc
B1
b
Fax:+961 9 620934/35Tel:+961 9 620 920S ectionalizingS witch
25
24
23
22
1 2 3 4 5 6 7 8 109 26
1. Lifting Lugs (Fig 5) 14. Line Sectionalizing switch and earth controls (Fig 14)
2. Dielectric refill plug 15. Led ( voltage indicator) (Fig 15)
3. Name Plate + single line diagram (Fig 6) 16. Medium voltage screened bushings (Fig 11)
4. Mimic and labels (Fig 7) 17. Elbow Connector (Fig 16)
5. Three phase main interrupter (Fig 8) 18. Grounding terminals (Fig 17)
6. Off load tap changer (Fig 9) 19. Medium voltage cable support + clamps (Fig 18)
7. LV porcelain bushings (Fig 10) 20. Medium voltage compartment (Fig 20)
8. Power meter (Optional) 21. Rollers
9. Current Transformers 22. Fuses
10. Power Meter Protection Fuses (optional) 23. Low voltage compartment (Fig 21)
11. Pressure relief valve (Fig 12) 24. Low voltage cable support + clamps
12. Dielectric level indicator (Fig 13) 25. Drainage and sampling device
13. Blocking device 26. Insulated device for drive (Hotstick) (Fig 19)
Fig 18 Medium voltage cable
support + clamps
Fig 19 Insulated device for
drive (Hotstick)
Fig 20 Medium voltage
compartment
Fig 21 Low voltage
compartment
-
7/28/2019 Compact Integrated Distribution Substation CIDS Catalog
11/12
ELECTRICAL EQUIPMENT INDUSTRIES COMPANY LTD.
P.O.Box 850175 Amman 11185
Amman, Jordan
Tel: (962) 6 5727861/2
Fax: (962) 6 5727863
E-mail: [email protected]
INTERNATIONAL TRANSFORMERS MATELEC LTD.
10th of Ramadan City, Egypt
Tel: (20) 2 4149004 - 2901795
Fax: (20) 2 4155614
E-mail: [email protected]
SAUDI MATELEC CO. FOR INDUSTRIES LTD.
Dabab Street, Dabab Bldg, 3rd floor, Office N 10
P.O.Box 52114, Riyadh 11563
Riyadh, Kingdom of Saudi Arabia
Tel: (966) 1 4029909
Fax: (966) 1 4024280
E-mail: [email protected]
TRANSFO MATELEC S.A.
ZI de Briangaud
35600 Redon, France
Tel: (33) 2 99711650
Fax: (33) 2 99721700E-mail: [email protected]
MATELEC S.A.L.
Amchit - Ghorfine
P.O.Box 12 Jbeil - Lebanon
Tel: (961) 9 620920
Fax: (961) 9 620934/5
E-mail: [email protected]
-