Training course- Sensors
- Communication options- Power supply & battery options- Masts- Accessories
- Preventive maintenance- Troubleshooting- Downloading configuration file
-
8/11/2019 AWSS 301 Training
2/18
AWSS301 Overview
Meteorological station for MIDAS IV
Configurable:
Sensors Wind, Temp. Hum., Pressure, Rain
Communications Modem, radio modem
Mechanics
Power supply 230VAC, 115 VAC, Solar
Accessories Mast, Obstruction light, Back up battery..
-
8/11/2019 AWSS 301 Training
3/18
Wind speed and direction
Wind measurement options: Mechanical sensors + transmitter + cross arm
WAA151, WAV151, WT521 Ultrasonic sensor + support arm
WAS425A, WAS425AH
Both options can be supplied withheating
Both options connected via RS232 line
to the logger (QML101)
-
8/11/2019 AWSS 301 Training
4/18
WAS425 & WAX151 data
WAA151 WAS425A
Measuring Range 0.4 - 75 m/s 0 - 65 m/s
Starting Threshold < 0.5 m/s 0 m/sAccuracy 0.4 m/s [ 0 - 4.5 m/s ]
0 - 3 % [ 4.5 - 65 m/s]
0.135 m/s [0 - 4.5 m/s]
3 % [4.5 - 65 m/s ]
WAV151 WAS425A
Measuring Range 0 - 360 0 - 360Starting Threshold < 0.4 m/s 0 m/s
Delay distance 0.4 m 0 m
Accuracy 3 % 2 %
Resolution 5.6 1
Operating temperature -50 ...+55 WAS425A: 0 ... +55WAS425AH: -55 ... +55
-
8/11/2019 AWSS 301 Training
5/18
Temperature and humidity
Temperature and humidity
measured with HMP45D (QMH102)Dew point calculated at MIDAS IV
Accessories that are in the delivery:
DKP12SUP1 support armDTR13 radiation shield
Mechanical installation kit
TemperatureRange -40 - +60 degrees CAccuracy +/- 0.2 degrees C
Relative humidity
Range 0.8 - 100 %Accuracy +/- 1 % at + 20 degrees C
-
8/11/2019 AWSS 301 Training
6/18
Atmospheric Pressure
Pressure measured with
PTB220/PMT16A1 transducer: PMT16A inside logger
2 transducers: PTB220AB inside box
3 transducers: PTB220AC inside box
QNH/QFE calculated at MIDAS IV
PMT16A
Range 600 - 1100 hPaAccuracy 0.3 hPaResolution 0.1 hPa
PTB220Range 500 - 1100 hPa
Accuracy 0.15 hPaResolution 0.1 hPa
-
8/11/2019 AWSS 301 Training
7/18
Rain amount
Rain amount measured withRG13 / RG13H (heated version)
0,2 mm resolution
Installed ~5 m from the maston a separate basement
-
8/11/2019 AWSS 301 Training
8/18
Communication:Modem & Radio modem
Vaisalas DMX501 insideQML101 data logger; 1200 bps
1 pair of communication
cables needed
max 10 km cabling distance
The sensor site protected
against voltage transientsThe MIDAS IV end of the
cabling is to be protected by
the customer/contractor
Modem andTransientprotection
-
8/11/2019 AWSS 301 Training
9/18
Communication: Modem& Radio modem
Satel 3as UHF radio modem
inside box; 9600 bps
Free UHF frequency needed
before delivery of the system
(380..470 MHz)
max 5 km distance
Line of sight needed between
sensor site and MIDAS IV end
antennaThe max cabling distance in the
MIDAS IV end between antenna
and MIDAS IV CDU: 20 m (forlonger cables amplifiers needed)
Radio modemand antenna
-
8/11/2019 AWSS 301 Training
10/18
Power supply & Battery back up
115 VAC or 230 VAC power
supply with voltage transientand over current protection
Optionally:
Solar power supply
6 Ah battery + charger inside
the box
or
48 Ah battery set + charger in a
separate box
6 Ah batteryCharger
DC converter
VoltagetransientprotectionFuses
-
8/11/2019 AWSS 301 Training
11/18
Mast options
DKP12,10 m pole mast for non
frangible installations with windsensors
EXEL11, 10 m fiber glass lattice
mast for frangible installationswith wind sensors
DKP15, 2.2 m pole mast for
installations without wind
sensors
For 10 m masts also lightning
spike; standard and heavy duty
(Franklin)
-
8/11/2019 AWSS 301 Training
12/18
Accessories
Obstruction light; Obelux LED
technology low intencity redobstruction light
Termination box, if long ground
cables need to be terminatedoutside the box
Additional guy wire set for
DKP12 in installations at sites
with heavy winds
Obstruction light
-
8/11/2019 AWSS 301 Training
13/18
Periodic maintenance
Please check the periodic maintenance for the
sensors in the sensor specific manuals
Obstruction light; Check that the LEDs in the light
are OK. (The more LEDs are inoperative, the lower
is the intensity of the light)
Battery back up: Disconnect the voltage supply tothe battery charger and check that the back up
time is according to product specification /
customer requirement. The back up time for with a
new battery is very long; app 3 days for 6 Ah
option and 1 - 2 weeks for 48 Ah option.
Clean the surface of the solar panel and measure
with multi meter that the unit is charging
-
8/11/2019 AWSS 301 Training
14/18
Trouble shootingProblem Probable cause Remedy
AWSS301 is sendingslashes(////) instead of oneor more of the sensorreadings.
Please note that slashesare sent if thecorresponding sensor isnot connected to theAWSS301.
The sensor wireconnections / sensorwires are defective.
Sensor(s) is(are)defettive
The sensor is missing.QML101 logger isexpecting all optionalsensors to beconnected. Slashesare OK for thesensors that are not
included in theAWSS301.
Check the terminal connections in the AWSSBOX301. Check that the wires are according tothe delivery documentation. If OK, check thecondition of the wires.
If above OK, the most probable cause of themissing data is a faulty sensor. In this case thesensor should be replaced.
AWSS301 is not sendinganything (nothing is seenon the screen).
Press and keep down the reset button for a fewseconds. AWSS301 will restart and display:"Using blank configuration". After this, theproper configuration must be downloaded!Type openand press enter. The command hasto be typed exactly right before it can beexecuted.
The terminalconnection is notopen.
Correct PC port and AWSS301 com portsettings and check the cable connection.
AWSS301 will not open forcommands.
AWSS301 is notreceiving power.
Check connections and power supply.
The Setup file doesnot exist in Cfgdirectory.
Copy or load the file to the correct directoryAfter reset, AWSS301displays "!Erroneous setupfile".
Setup file is not
executable.
Type "chmod Filenamerwx".
-
8/11/2019 AWSS 301 Training
15/18
Configuration file
AWSS301 is always delivered with factory
installed configuration file
The used configuration file depends on the
selected communication option and pressure
optionIf wrong file is installed, the AWSS301 does not
perform any measurements or transmit data
In the following slides there is described how theconfiguration file is loaded
-
8/11/2019 AWSS 301 Training
16/18
Loading the configuration file
Start HyperTerminal
(Win 95/NT).
Start > Programs > Accessories >
HyperTerminal> HyperTerminal(hypertrm.exe)
Give name
"AWSS301" to the
new connection.Click OK.
9901-04
The Phone Number
dialog will open.
For Connect Using,
choose Direct to
Com 1(or another
Com port if you arenot using port 1).
Click OK.
9901-04
-
8/11/2019 AWSS 301 Training
17/18
Loading the configuration file
The COM
Propertiesdialog
will open. Make the
settings according tothe picture.
Click OKand the
connection to
AWSS301 is set up.
After typing open,
you can start givingcommands to
AWSS301.
9901-04
-
8/11/2019 AWSS 301 Training
18/18
Loading the configuration file
To be able to transfer
files to and from
AWSS301, you need to
choose the correct
transfer protocol:
ZModem.
When loading a new setup file to AWSS301 you must first delete
the old file: ("default" denotes the name of the setup file)
cd Cfg
del default
After that, give command zr
Choose Send File from Transfer menu. Choose Zmodem for
protocol and click Sendto load the setup into AWSS301.
9901-045
Make the setup executable:
chmod default rwx
Reset AWSS301 by giving command reset
When retrieving a log file from AWSS301, choose Receive file
from the Transfer menu. Choose Zmodem for protocol. Choose
also the directory where the retrieved file is to be stored.