    AWSS301

    Training course- Sensors

    - Communication options- Power supply & battery options- Masts- Accessories

    - Preventive maintenance- Troubleshooting- Downloading configuration file

  • 8/11/2019 AWSS 301 Training

    2/18

    AWSS301 Overview

    Meteorological station for MIDAS IV

    Configurable:

    Sensors Wind, Temp. Hum., Pressure, Rain

    Communications Modem, radio modem

    Mechanics

    Power supply 230VAC, 115 VAC, Solar

    Accessories Mast, Obstruction light, Back up battery..

  • 8/11/2019 AWSS 301 Training

    3/18

    Wind speed and direction

    Wind measurement options: Mechanical sensors + transmitter + cross arm

    WAA151, WAV151, WT521 Ultrasonic sensor + support arm

    WAS425A, WAS425AH

    Both options can be supplied withheating

    Both options connected via RS232 line

    to the logger (QML101)

  • 8/11/2019 AWSS 301 Training

    4/18

    WAS425 & WAX151 data

    WAA151 WAS425A

    Measuring Range 0.4 - 75 m/s 0 - 65 m/s

    Starting Threshold < 0.5 m/s 0 m/sAccuracy 0.4 m/s [ 0 - 4.5 m/s ]

    0 - 3 % [ 4.5 - 65 m/s]

    0.135 m/s [0 - 4.5 m/s]

    3 % [4.5 - 65 m/s ]

    WAV151 WAS425A

    Measuring Range 0 - 360 0 - 360Starting Threshold < 0.4 m/s 0 m/s

    Delay distance 0.4 m 0 m

    Accuracy 3 % 2 %

    Resolution 5.6 1

    Operating temperature -50 ...+55 WAS425A: 0 ... +55WAS425AH: -55 ... +55

  • 8/11/2019 AWSS 301 Training

    5/18

    Temperature and humidity

    Temperature and humidity

    measured with HMP45D (QMH102)Dew point calculated at MIDAS IV

    Accessories that are in the delivery:

    DKP12SUP1 support armDTR13 radiation shield

    Mechanical installation kit

    TemperatureRange -40 - +60 degrees CAccuracy +/- 0.2 degrees C

    Relative humidity

    Range 0.8 - 100 %Accuracy +/- 1 % at + 20 degrees C

  • 8/11/2019 AWSS 301 Training

    6/18

    Atmospheric Pressure

    Pressure measured with

    PTB220/PMT16A1 transducer: PMT16A inside logger

    2 transducers: PTB220AB inside box

    3 transducers: PTB220AC inside box

    QNH/QFE calculated at MIDAS IV

    PMT16A

    Range 600 - 1100 hPaAccuracy 0.3 hPaResolution 0.1 hPa

    PTB220Range 500 - 1100 hPa

    Accuracy 0.15 hPaResolution 0.1 hPa

  • 8/11/2019 AWSS 301 Training

    7/18

    Rain amount

    Rain amount measured withRG13 / RG13H (heated version)

    0,2 mm resolution

    Installed ~5 m from the maston a separate basement

  • 8/11/2019 AWSS 301 Training

    8/18

    Communication:Modem & Radio modem

    Vaisalas DMX501 insideQML101 data logger; 1200 bps

    1 pair of communication

    cables needed

    max 10 km cabling distance

    The sensor site protected

    against voltage transientsThe MIDAS IV end of the

    cabling is to be protected by

    the customer/contractor

    Modem andTransientprotection

  • 8/11/2019 AWSS 301 Training

    9/18

    Communication: Modem& Radio modem

    Satel 3as UHF radio modem

    inside box; 9600 bps

    Free UHF frequency needed

    before delivery of the system

    (380..470 MHz)

    max 5 km distance

    Line of sight needed between

    sensor site and MIDAS IV end

    antennaThe max cabling distance in the

    MIDAS IV end between antenna

    and MIDAS IV CDU: 20 m (forlonger cables amplifiers needed)

    Radio modemand antenna

  • 8/11/2019 AWSS 301 Training

    10/18

    Power supply & Battery back up

    115 VAC or 230 VAC power

    supply with voltage transientand over current protection

    Optionally:

    Solar power supply

    6 Ah battery + charger inside

    the box

    or

    48 Ah battery set + charger in a

    separate box

    6 Ah batteryCharger

    DC converter

    VoltagetransientprotectionFuses

  • 8/11/2019 AWSS 301 Training

    11/18

    Mast options

    DKP12,10 m pole mast for non

    frangible installations with windsensors

    EXEL11, 10 m fiber glass lattice

    mast for frangible installationswith wind sensors

    DKP15, 2.2 m pole mast for

    installations without wind

    sensors

    For 10 m masts also lightning

    spike; standard and heavy duty

    (Franklin)

  • 8/11/2019 AWSS 301 Training

    12/18

    Accessories

    Obstruction light; Obelux LED

    technology low intencity redobstruction light

    Termination box, if long ground

    cables need to be terminatedoutside the box

    Additional guy wire set for

    DKP12 in installations at sites

    with heavy winds

    Obstruction light

  • 8/11/2019 AWSS 301 Training

    13/18

    Periodic maintenance

    Please check the periodic maintenance for the

    sensors in the sensor specific manuals

    Obstruction light; Check that the LEDs in the light

    are OK. (The more LEDs are inoperative, the lower

    is the intensity of the light)

    Battery back up: Disconnect the voltage supply tothe battery charger and check that the back up

    time is according to product specification /

    customer requirement. The back up time for with a

    new battery is very long; app 3 days for 6 Ah

    option and 1 - 2 weeks for 48 Ah option.

    Clean the surface of the solar panel and measure

    with multi meter that the unit is charging

  • 8/11/2019 AWSS 301 Training

    14/18

    Trouble shootingProblem Probable cause Remedy

    AWSS301 is sendingslashes(////) instead of oneor more of the sensorreadings.

    Please note that slashesare sent if thecorresponding sensor isnot connected to theAWSS301.

    The sensor wireconnections / sensorwires are defective.

    Sensor(s) is(are)defettive

    The sensor is missing.QML101 logger isexpecting all optionalsensors to beconnected. Slashesare OK for thesensors that are not

    included in theAWSS301.

    Check the terminal connections in the AWSSBOX301. Check that the wires are according tothe delivery documentation. If OK, check thecondition of the wires.

    If above OK, the most probable cause of themissing data is a faulty sensor. In this case thesensor should be replaced.

    AWSS301 is not sendinganything (nothing is seenon the screen).

    Press and keep down the reset button for a fewseconds. AWSS301 will restart and display:"Using blank configuration". After this, theproper configuration must be downloaded!Type openand press enter. The command hasto be typed exactly right before it can beexecuted.

    The terminalconnection is notopen.

    Correct PC port and AWSS301 com portsettings and check the cable connection.

    AWSS301 will not open forcommands.

    AWSS301 is notreceiving power.

    Check connections and power supply.

    The Setup file doesnot exist in Cfgdirectory.

    Copy or load the file to the correct directoryAfter reset, AWSS301displays "!Erroneous setupfile".

    Setup file is not

    executable.

    Type "chmod Filenamerwx".

  • 8/11/2019 AWSS 301 Training

    15/18

    Configuration file

    AWSS301 is always delivered with factory

    installed configuration file

    The used configuration file depends on the

    selected communication option and pressure

    optionIf wrong file is installed, the AWSS301 does not

    perform any measurements or transmit data

    In the following slides there is described how theconfiguration file is loaded

  • 8/11/2019 AWSS 301 Training

    16/18

    Loading the configuration file

    Start HyperTerminal

    (Win 95/NT).

    Start > Programs > Accessories >

    HyperTerminal> HyperTerminal(hypertrm.exe)

    Give name

    "AWSS301" to the

    new connection.Click OK.

    9901-04

    The Phone Number

    dialog will open.

    For Connect Using,

    choose Direct to

    Com 1(or another

    Com port if you arenot using port 1).

    Click OK.

    9901-04

  • 8/11/2019 AWSS 301 Training

    17/18

    Loading the configuration file

    The COM

    Propertiesdialog

    will open. Make the

    settings according tothe picture.

    Click OKand the

    connection to

    AWSS301 is set up.

    After typing open,

    you can start givingcommands to

    AWSS301.

    9901-04

  • 8/11/2019 AWSS 301 Training

    18/18

    Loading the configuration file

    To be able to transfer

    files to and from

    AWSS301, you need to

    choose the correct

    transfer protocol:

    ZModem.

    When loading a new setup file to AWSS301 you must first delete

    the old file: ("default" denotes the name of the setup file)

    cd Cfg

    del default

    After that, give command zr

    Choose Send File from Transfer menu. Choose Zmodem for

    protocol and click Sendto load the setup into AWSS301.

    9901-045

    Make the setup executable:

    chmod default rwx

    Reset AWSS301 by giving command reset

    When retrieving a log file from AWSS301, choose Receive file

    from the Transfer menu. Choose Zmodem for protocol. Choose

    also the directory where the retrieved file is to be stored.