    SELECTION GUIDE

    FIXED SPEED CONTROLDIRECT ONLINE STARTERS

    SOFT STARTERS

    THE INTELLIGENT MOTOR CONTROL SOLUTION

    FOR YOUR APPLICATION REQUIREMENTS

  • 7/31/2019 Dolsmc Sg001 en p

    2/32

  • 7/31/2019 Dolsmc Sg001 en p

    3/321

    Rockwell Automation, Allen-Bradley, PowerFlex, ArmorPoint, ArmorConnect, ArmorStartare registered trademarks of Rockwell Automation. DeviceLogix, DeviceNet are trademarks of

    Rockwell Automation.

    Intelligent Motor Control 2

    Intelligent Motor Control with Fixed Speed Starters 4

    Product features 6

    Product selection

    E1 Plus Electronic Overload Relays 8

    E3 and E3 Plus Electronic Overload Relays 10

    825-P Modular Protection System 12

    SMC-Flex Smart Motor Controllers 14

    ArmorStart Distributed Motor Controllers 18

    Short-Circuit Coordination 24Functionality Overview 26

  • 7/31/2019 Dolsmc Sg001 en p

    4/322

    FIXED SPEEDCONTROL

    Direct OnlineStarters

    SoftStarters

    We understand that you need to control performance, reduce

    downtime, improve safety, increase productivity, perform

    diagnostics. Thats why weve combined leading-edge motor

    control and protection devices with the advanced networking

    and diagnostic capabilities of Rockwell Automations Integrated

    Architecture to provide you with Intelligent Motor Control.

    With solutions for a variety of motor control requirements and

    devices hosting in-built intelligence, control of your motor

    applications can be truly integrated into your solution. Seamless

    integration allows your to monitor, control, program and

    interrogate your motor control solutions to achieve the

    efficiency, reliability and control you demand. With different

    levels of integration available, there is an integrated solution

    ideal for you.

    AN INTEGRAL PART OF YOUR

    INTEGRATEDARCHITECTURE

    WHAT YOU CAN ACHIEVE WITH INTEGRATED ARCHITECTURE

    AND INTELLIGENT MOTOR CONTROL SOLUTIONS... Optimise motor performance through intelligent equipment and networks

    Reduce your energy consumption and increase efficiency Reduce downtime in the event of drive damage with automatic device replacement (ADR)

    Alerts you about motor problems before a failure occurs

    Embed safety functionality to protect your process, personnel and equipment health

    Achieve seamless communication and system visibility for increased system performance,

    simplified troubleshooting and reduced startup times

    and much more...

  • 7/31/2019 Dolsmc Sg001 en p

    5/323

    MOTIONCONTROL

    VARIABLE SPEEDCONTROL

    ServoMotors

    ServoDrives

    Medium VoltageAC Drives

    Low VoltageAC Drives

    NetLinx

    (EtherNet/IP, ControlNet, DeviceNet)

    EngineeredDrive Solutions

  • 7/31/2019 Dolsmc Sg001 en p

    6/324

    E3 AND E3 PLUS -ELECTRONIC OVERLOAD RELAYS 0.4...860 A Current Range

    9...5000 A Current Range with

    Current Transformer

    DeviceNet Communication

    integrated

    Adjustable trip Class (530)

    Programmable trip and

    warning settings

    Diagnostic functions(History of last 5 trips)

    DeviceLogix component technology

    RELAYS E3 2 Inputs 1 Output

    RELAYS E3 PLUS 4 Inputs 2 Outputs

    Built-in ground faultsensor (through 90 A rating)

    PTC thermistor input

    FIXED SPEEDCONTROL

    Direct OnlineStarters

    E1 PLUS -ELECTRONIC OVERLOAD RELAYS 0.1...800 A Current Range

    Self-Powered

    Fast Phase Loss Protection

    Wide adjustment Range (5:1)

    Low Energy

    Consumption (150mW)

    Visible Trip Indication

    Side mount Communications Modules

    825-P - MODULARPROTECTION SYSTEM 0.55000 A Current Range

    Suitable for low- and medium- voltage

    applications

    Modular design with pluggable options

    - Voltage input cards, including

    DeviceNet communications

    - RTD scanner module

    Comprehensive protection functions

    Built-in keypad and backlit 2-Line LCD

    Status LEDs

    3 Output relays

    2 Configurable inputs

  • 7/31/2019 Dolsmc Sg001 en p

    7/325

    SoftStarters

    Direct online StartingRockwell Automation offers a complete portfolio ofAllen-Bradley electronic motor protection relays withcommunications that allow you immediate access to statusinformation, motor performance data, and diagnostics,as well as the capability to perform control functions.

    Soft StartingSmart Motor Controllers (SMCs) minimize mechanicalwear resulting from full-voltage starting of AC inductionmotors, enabling longer system life as well as limit linedisturbances from inrush currents, resulting in reduceddowntime.

    Distributed Motor ControlFor your applications needing machine mounted motorcontrol, the ArmorStart Distributed Motor Controllers offera simple, cost-effective method of integrating motorcontrol, I/O and network capabilities in your on-machinearchitecture. The ArmorStart is an integrated,pre-engineered combination starter for full voltage DOL,reversing, Soft starting and variable speed drive applica-tions. The components are mounted closer to the applica-tion or on the machine reducing panel space as well as

    wiring and conduit requirements making it easier to installand start-up. Save more time by configuring intelligentdevices via the network and reduce at the same timepotential errors.

    ARMORSTART 280/281D -DISTRIBUTED MOTOR CONTROLLERS 0.187.5 kW (400V)

    Full Voltage DOL and Reversing starting

    IP69K/NEMA Type 4X or IP67/

    NEMA Type 4 enclosure ratings

    Modular plug and play design

    Network Communications with

    DeviceNet including DeviceLogix

    4 Inputs and 2 Outputs

    Quick Disconnects for I/O,

    Communications, Motor Connection

    and Control Power

    ARMORSTART 283D -DISTRIBUTED MOTOR CONTROLLERS 0.375.5 kW (400V)

    Current Limit Start, Soft Start, Soft Stop

    IP69K/NEMA Type 4X or IP67/

    NEMA Type 4 enclosure ratings

    Modular plug and play design

    Network Communications with

    DeviceNet including DeviceLogix

    4 Inputs and 2 Outputs

    Quick Disconnects for I/O,

    Communications, Motor Connection

    and Control Power

    SMC-FLEX -SMART MOTOR COTROLLERS 11250/1600 A Current Range

    Soft Start

    Current Limit Start

    Full Voltage

    Preset Slow Speed

    Soft Stop

    Options

    Pump Control

    Braking Control

  • 7/31/2019 Dolsmc Sg001 en p

    8/326

    PROTECTION CONTROL

    COMMUNICATIONS

    E3 Overload Relays control functions delivereffective motor management to help preventand minimize production downtime. Criticalprotective functions can prevent motor damageand provide advance notification of a machinesperformance being outside the boundaries ofnormal operation.Network communication delivers immediateaccess to motor performance and diagnosticdata in addition to seamless control. IntegratedI/O provides convenient local termination ofmotor-related inputs and outputs, simplifyingthe control architecture. DeviceLogix compo-nent technology increases the control possibili-ties with function block programs that operate

    at the device level.

    E1 Plus electronic overload relays are the indus-trys first modular self-powered devices, settinga new standard for entry level motor protection.The network communications modules expandthe functionality. Its compact, simplified control,and flexibilitys allows you to network motorstarters more cost efficiently. Streamlineprocesses with enhanced control, protection,monitoring, and diagnostic capability for im-proved operating efficiency.

    The unique line-side over molded power con-nections on the E1 Plus, on the E3, and E3 Plusmake for a sturdy two-component starter assem-bly that is unmatched in the industry. The pre-formed power connections allow for easy starter

    assembly every time.

    NETWORKCOMMUNICATION

  • 7/31/2019 Dolsmc Sg001 en p

    9/327

    IP69K Rated ArmorStart!The IP69K rated ArmorStart Distributed Motor Controlleris suitable for harsh production environments. Rated forenvironment high pressure wash down with causticchemicals used in the food and beverage industry(i.e. sodium hydroxide exposure). The IP69K ratedArmorStart offers the same features as the IP67 ratedArmorStart.

    What is DeviceLogix?DeviceLogix is a stand-alone Boolean program that resideswithin the ArmorStart.

    DeviceLogix is programmed using Boolean math operationssuch as AND, OR, NOT, Timers, Counters, and Latches.

    RSNetWorx for DeviceNet Version 3.0 or later is requiredto program the device.

    Peer to PeerCommunications (ZIP)The new Zone Control capabilities of ArmorStart DistributedMotor Controller is ideal for large horsepower motoredconveyors. The ArmorStart Distributed Motor Controller havebuilt-in DeviceNet Communications, DeviceLogix technologyand the added Zone Interlocking Parameters (ZIP) whichallows one ArmorStart to consume data directly from upto four other DeviceNet nodes without going through thenetwork scanner. These direct communications betweenconveyor zones are beneficial in merge, diverter and

    accumulation conveyor applications.

    Line ConnectionDelta Connections

    M

    Benefits of using DeviceLogix

    Faster sense-to-actuate response Local processing Higher network performance

    Increased system reliability Improved diagnostics and reduced troubleshooting Reducing potential points of failure at system level Increasing uptime through distributing ControlLogic

    throughout system

    Enables reliability in operation under failures or duringmaintenance operations

    Increased system/machine modularity Distributing control on the machine Smaller programs in the master system scan

    and processing times

    The SMC-Flex is a compact and cost-effective packagefor your production applications. As standard, theSMC-Flex includes I/O, electronic overload, integralbypass, advanced communication capabilities, motorstarting capabilities for both star-delta and standardsquirrel-cage induction motors, advanced protectionand diagnostics.

    The SMC-Flex is also available for medium voltageapplications with the same features and benefits forcontrolling motors rated up to 7.2 kV and 7500 hp(5600 kW).

    The SMC-Flex provides 3 Phase Controland excellent performance in a

    compact design for your standardsquirrel cage or Star-Delta

    induction motors.

    M3~

    2/T1 4/T2 6/T3

    3/L21/L1 5/L3

  • 7/31/2019 Dolsmc Sg001 en p

    10/328

    Description Mounts to ContactorAdjustment Range

    [A] Cat. No.

    Three-Phase Devices 193-ED

    0.127 A Current Range

    Fixed Trip Class 10

    Manual Reset

    100-C09100-C23

    0.10.5 193-ED1AB

    0.21.0 193-ED1BB

    1.05.0 193-ED1CB

    3.216 193-ED1DB

    5.427 193-ED1EB

    Three-Phase Devices 193-EE

    0.1800 A Current Range

    Selectable Trip Class (10, 15, 20 or 30)

    Selectable Manual/Auto-Manual Reset

    Single-Phase and Devices with Cage Clamp ControlTerminals are also available,see publication 193-SG009_-EN-P.

    100-C09100-C23 0.10.5 193-EEAB

    100-C09100-C23 0.21.0 193-EEBB

    100-C09100-C23 1.05.0 193-EECB

    100-C09100-C23 3.216 193-EEDB

    100-C09100-C23 5.427 193-EEEB

    100-C30100-C43 5.427 193-EEED

    100-C30100-C43 945 193-EEFD

    100-C60100-C85 1890 193-EEGE

    100-D95100-D180 30150 193-EEHF

    100-D95100-D180 40200 193-EEJF

    100-D210100-D420 40200 193-EEJG

    100-D210100-D420 60300 193-EEKG100-D210100-D420 100500 193-EELG

    100-D630100-D860 120600 193-EEMH

    100-D630100-D860 160800 193-EENH

    0.1...800 A Current Range

    Self-Powered

    Fast Phase Loss Protection

    Wide Adjustment Range (5:1)

    1 N.O. and 1 N.C. Isolated auxiliary Contacts

    (B600, AC-15 Rated)

    Low Energy Consumption (150 mW)

    Ambient Temperature Compensation

    Visible Trip Indication

    Jam/Remote Reset optional accessoiresSide-mount Modules for enhanced Motor Protection

    E1 PLUS

  • 7/31/2019 Dolsmc Sg001 en p

    11/329

    Description For Use With Cat. No.

    DeviceNet Communications ModuleIntegrated I/O allow simplification of the networkarchitecture, providing local connection of motor starterrelated inputs and outputs.2 Inputs 24V DC rated, module supplied1 Output B300 rated

    193-EE 193-EDN

    Jam Protection Module with Remote ResetSide-mount module with trip level settings of 150, 200, 300and 400% FLA, and delay time settings of 0.5, 1.0, 2.0and 4 seconds. For remote resetting of a trip condition.Supply voltage required.

    193-EE 193-EJM

    Ground Fault Module with Remote ResetSide-mount module for core-balanced ground fault protection,adjustable trip level 20 mA...5 A. Supply voltage required.

    193-EE 193-EGF

    Ground Fault/Jam Module with Remote ResetSide-mount module for core-balanced ground fault protection,adjustable trip level 20 mA...5 A; Jam protection with fixed trip levelsetting of 400% FLA, fixed delay time setting of 0.5 seconds.

    Supply voltage required.

    193-EE 193-EGJ

    Core Balance Ground Fault SensorsMax. 45 A; Window 19.1 mmMax. 90 A; Window 39.6 mm

    100-C09...C37 193-CBCT1

    100-C09...C85 193-CBCT2

    Remote Reset ModuleFor remote resetting of a trip condition.Supply voltage required.

    193-EE 193-ERR

    DIN Rail/Panel AdapterFor separate mounting can be mountedto top-hat rail EN 50 022-35.

    193-ED1_B, 193-EE_B 193-EPB193-ED1_B, 193-EE_B 193-EPD

    193-EE_E 193-EPE

    External Reset ButtonFor enclosed, through-the-door reset applications.Metal construction IP66, non-illuminated with rod(length: 142 mm, adjustable range 141159 mm).Refer to the 800F catalog pages for additional types.

    193-ED (all)193-EE (all)

    800FP-R611

    800F-ATR08

    Current Adjustment ShieldPrevents inadvertent adjustment of the current setting.Must be ordered in multiples of package quantities.Package Quantity = 10

    193-ED (all)193-EE (all)592-EE (all)

    193-BC8

    External Reset AdapterFor enclosed, through-the-door reset applications.Use with External Reset Button.

    193-ED (all)193-EE_B,193-EE_D,193-EE_E

    193-ERA

    Terminal LugsSet of 2Protection class IP2X per IEC 60529 and DIN 40 050

    100-D140, 100-D180,100-D95ED180E,193-EC_F, 193 -EE_F

    100-DTB180

    100-D210...100-D420,193-EC_G, 193-EF2C,

    193-EE_G100-DTB420

    Terminal CoversProtection class IP20 per IEC 60529 and DIN 40 050For direct-on-line, reversing, two-speed,and wye-delta/star-delta assemblies

    100-D95100-D180,193-EC_F, 193 -EE_F 100-DTC180

    100-D210...100-D420,193-EC_G, 193-EE_G

    100-DTC420

    100-D630100-D860,193-EC_H, 193-EE_H

    100-DTC860

    Phase Barriers

    Set of 4

    100-D630D860,

    193-EC_H, 193-EE_H

    100-DPB860

  • 7/31/2019 Dolsmc Sg001 en p

    12/3210

    Relay193-EC1

    Relay193-EC2

    Mounts to Contactor Adjustment Range [A] Cat. No. Cat. No.

    100-C09100-C23

    0.42 193-EC1PB 193-EC2PB

    15 193-EC1AB 193-EC2AB

    315 193-EC1BB 193-EC2BB

    525 193-EC1CB 193-EC2CB

    100-C30100-C43

    15 193-EC1AD 193-EC2AD

    315 193-EC1BD 193-EC2BD

    525 193-EC1CD 193-EC2CD

    945 193-EC1DD 193-EC2DD

    100-C60100-C85945 193-EC1DE 193-EC2DE

    1890 193-EC1EE 193-EC2EE

    100-D95100-D18028140 1 193-EC1FF 193-EC2FF

    42210 1 193-EC1GF 193-EC2GF

    100-D210100-D420

    42210 1 193-EC1GG 193-EC2GG

    60302 1 193-EC1HG 193-EC2HG

    84420 1 193-EC1JG 193-EC2JG

    100-D630100-D860125630 1 193-EC1KH 193-EC2KH

    172860 1 193-EC1LH 193-EC2LH

    0.4...860 A Current Range

    9...5000 A Current Range with Current Transformer

    DeviceNet communication integrated

    LED indicators

    Test / Reset button Adjustable trip Class (530)

    Integrated I/O s E3: 2 Inputs / 1 Output

    E3 Plus: 4 Inputs / 2 Outputs

    Low-level ground (earth) fault protection 193-EC2Ground fault range 15 A

    PTC thermistor input 193-EC2

    Programmable trip and warning settings

    Diagnostic functions (History of last 5 trips)

    DeviceLogix (series B)

    1 Does not include terminal lugs.

    E3 & E3 PLUS

  • 7/31/2019 Dolsmc Sg001 en p

    13/3211

    Description For Use With Cat. No.

    DIN Rail/Panel Adapter 1

    193-EC__B 193-ECPM1

    193-EC_D, 193-EC_ZZ 193-ECPM2

    193-EC__E 193-ECPM3

    AC Input Interface Modulerated 110/120V AC, 50/60 Hz

    193-EC all592-EC all 193-EIMD

    Core Balance Ground Fault Sensor 193-EC2_F, 193-EC2_G,193-EC2_H, 193-EC2ZZ 825-CBCT

    Terminal LugsSet of 2Protection class IP2X per IEC 60529 and DIN 40 050

    100-D140, 100-D180,100-D95ED180E,193-EC_F, 193-EE_F

    100-DTB180

    100-D210...100-D420,193-EC_G, 193-EF2C,

    193-EE_G100-DTB420

    Terminal CoversProtection class IP20 per IEC 60529 and DIN 40 050For direct-on-line, reversing, two-speed,and wye-delta/star-delta assemblies

    100-D95100-D180,193-EC_F, 193-EE_F

    100-DTC180

    100-D210...100-D420,193-EC_G, 193-EE_G 100-DTC420

    100-D630100-D860,193-EC_H, 193-EE_H 100-DTC860

    Phase BarriersSet of 4

    100-D630D860,193-EC_H, 193-EE_H

    100-DPB860

    CT RatioFLA SettingRange (A) CT Ratio

    FLA SettingRange (A) CT Ratio

    FLA SettingRange (A)

    50:5 945 300:5 60302 1200:5 2401215

    100:5 1890 500:5 84420 2500:5 4502250

    150:5 28140 600:5 125630 5000:5 10005000

    200:5 42210 800:5 172860

    Description Adjustment Range [A] Cat. No.

    2 Inputs 1 Output 95000 193-EC1ZZ

    4 Inputs 2 Outputs Ground fault sensor input PTC thermistor input

    DeviceLogix

    95000 193-EC2ZZ

    Current transformers supplied by customer.Order panel adapter 193-ECPM2 separately. See table below for CT Ratio to FLA setting range correlation. Discount Schedule MPC

    1 The electronic motor protection relay can be mounted separately to top-hat rail EN 50 02-35.

  • 7/31/2019 Dolsmc Sg001 en p

    14/32

  • 7/31/2019 Dolsmc Sg001 en p

    15/3213

    Description Cat. No.

    Voltage Input CardMonitoring of VA, VB, VC, and VN

    240V AC Max. 1 825-PVS

    Expansion I/O Card(3) Inputs(4) Output Relays(1) 420 mA Analog Output

    120V AC Rated Inputs 1 825-PIOD

    24V DC Rated Inputs 1 825-PIOR

    DeviceNet Communication CardDeviceLogix technology, Node address selection switches, 1ODVA conformance tested

    825-PDN

    Modbus RTU Communication Card 1 825-PMB

    M8 connectionsSet of 34 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.)Universally applicable

    Weight: 230 g

    825-MVM

    M8 connectionsSet of 34 x 20 x 117 mm (180 A max.)Universally applicable

    825-MVM2

    M6 lower connectionsSet of 3For mounting on 100-D95 and 100-D110 contactors with conventional coil

    825-MVS

    M8 lower connectionsSet of 3

    For mounting on 100-D140, 100-D180 conventional and100-D95E100-D180E contactors with electronic coil 825-MVS2

    Terminal ShieldsSet of 2Protection class IP10 per IEC 60529and DIN 40 050For direct-on-line, reversing, two-speed,and wye-delta/star-delta assemblies

    100-D95, 100-D110 100-DTS110

    100-D140, 100-D180,100-D95-E100-D180-E 100-DTS180

    100-D210...100-D420 100-DTS420

    Terminal LugsSet of 2Protection class IP2X per IEC 60529and DIN 40 050

    100-D95, 100-D110 100-DTB110

    100-D140, 100-D180,

    100-D95ED180E,193-EC_F, 193-EE_F

    100-DTB180

    100-D210...100-D420,193-EC_G, 193-EF2C,

    193-EE_G100-DTB420

    Thermal Utilization Meter

    For display of percentthermal capacity utilizedRequires the use of an

    Expansion I/O Card

    825-MTUM

    Connection cable (replacement)825-P to 825-MCM connection

    825-MCA

  • 7/31/2019 Dolsmc Sg001 en p

    16/3214

    Rating for lineconnection ?

    Rating for deltaconnection ?

    WithoutOption

    With PumpControl Option

    With BrakingControl Option

    MotorCurrent

    [A]400V[kW]

    MotorCurrent

    [A]400V[kW] Control Voltage Cat. No. Cat. No. Cat. No.

    15 2.2 1.78.7 4100...240V AC 50/60 Hz 150-F5NBD 150-F5NBDB 150-F5NBDD

    24V AC/DC 150-F5NBR 150-F5NBRB 150-F5NBRD

    5...25 11 8.743 22100...240V AC 50/60 Hz 150-F25NBD 150-F25NBDB 150-F25NBDD

    24V AC/DC 150-F25NBR 150-F25NBRB 150-F25NBRD

    8.6...43 22 14.974 37100...240V AC 50/60 Hz 150-F43NBD 150-F43NBDB 150-F43NBDD

    24V AC/DC 150-F43NBR 150-F43NBDR 150-F43NBDR

    12...60 30 20.8...104 55100...240V AC 50/60 Hz 150-F60NBD 150-F60NBDB 150-F60NBDD

    24V AC/DC

    150-F60NBR 150-F60NBRB 150-F60NBRD17...85 45 29.4147 75

    100...240V AC 50/60 Hz 150-F85NBD 150-F85NBDB 150-F85NBDD

    24V AC/DC 150-F85NBR 150-F85NBRB 150-F85NBRD

    27108 55 47187 90100...240V AC 50/60 Hz 150-F108NBD 150-F108NBDB 150-F108NBDD

    24V AC/DC 150-F108NBR 150-F108NBRB 150-F108NBRD

    34135 75 59234 132100...240V AC 50/60 Hz 150-F135NBD 150-F135NBDB 150-F135NBDD

    24V AC/DC 150-F135NBR 150-F135NBRB 150-F135NBRD

    67201 110 116348 160100...240V AC 50/60 Hz 150-F201NBD 150-F201NBDB 150-F201NBDD

    24V AC/DC 150-F201NBR 150-F201NBRB 150-F201NBRD

    84251 132 145435 250100...240V AC 50/60 Hz 150-F251NBD 150-F251NBDB 150-F251NBDD

    24V AC/DC 150-F251NBR 150-F251NBRB 150-F251NBRD

    106317 160 183549 135100...240V AC 50/60 Hz 150-F317NBD 150-F317NBDB 150-F317NBDD

    24V AC/DC

    150-F317NBR 150-F317NBRB 150-F317NBRD

    120361 200 208625 355100...240V AC 50/60 Hz 150-F361NBD 150-F361NBDB 150-F361NBDD

    24V AC/DC 150-F361NBR 150-F361NBRB 150-F361NBRD

    160480 250 277831 450100...240V AC 50/60 Hz 150-F480NBD 150-F480NBDB 150-F480NBDD

    24V AC/DC 150-F480NBR 150-F480NBRB 150-F480NBRD

    208625 355 283850 500110/120V AC 50/60 Hz 150-F625NBE 150-F625NBEB 150-F625NBED

    230/240V AC 50/60 Hz 150-F625NBA 150-F625NBAB 150-F625NBAD

    260780 450 300900 500110/120V AC 50/60 Hz 150-F780NBE 150-F780NBEB 150-F780NBED

    230/240V AC 50/60 Hz 150-F780NBA 150-F780NBAB 150-F780NBAD

    323...970 560 4001200 710110/120V AC 50/60 Hz 150-F970NBE 150-F970NBEB 150-F970NBED

    230/240V AC 50/60 Hz 150-F970NBA 150-F970NBAB 150-F970NBAD

    4161250 710 5331600 900110/120V AC 50/60 Hz 150-F1250NBE 150-F1250NBEB 150-F1250NBED

    230/240V AC 50/60 Hz 150-F1250NBA 150-F1250NBAB 150-F1250NBAD

    11250/1600 A Current Range

    Built-in Electronic Overload Protection

    Soft Start

    Current Limit Start

    Dual Ramp Full Voltage

    Linear Speed Acceleration

    Preset Slow Speed

    Soft Stop

    Options

    Pump Control

    Braking Control

    SMC-FLEX

  • 7/31/2019 Dolsmc Sg001 en p

    17/3215

    Rating for lineconnection?

    Rating for deltaconnection ?

    WithoutOption

    With PumpControl Option

    With BrakingControl Option

    MotorCurrent

    [A]400V[kW]

    MotorCurrent

    [A]400V[kW] Control Voltage Cat. No. Cat. No. Cat. No.

    15 2.2 1.78.7 4100...240V AC 50/60 Hz 150-F5NCD 150-F5NCDB 150-F5NCDD

    24V AC/DC 150-F5NBCR 150-F5NCRB 150-F5NCRD

    5...25 11 8.743 22100...240V AC 50/60 Hz 150-F25NCD 150-F25NCDB 150-F25NCDD

    24V AC/DC 150-F25NCR 150-F25NCRB 150-F25NCRD

    8.6...43 22 14.974 37100...240V AC 50/60 Hz 150-F43NCD 150-F43NCDB 150-F43NCDD

    24V AC/DC 150-F43NCR 150-F43NCDR 150-F43NCDR

    12...60 30 20.8...104 55100...240V AC 50/60 Hz 150-F60NCD 150-F60NCDB 150-F60NCDD

    24V AC/DC 150-F60NCR 150-F60NCRB 150-F60NCRD

    17...85 45 29.4147 75100...240V AC 50/60 Hz 150-F85NCD 150-F85NCDB 150-F85NCDD

    24V AC/DC 150-F85NCR 150-F85NCRB 150-F85NCRD

    27108 55 47187 90100...240V AC 50/60 Hz 150-F108NCD 150-F108NCDB 150-F108NCDD

    24V AC/DC 150-F108NCR 150-F108NCRB 150-F108NCRD

    34135 75 59234 132

    100...240V AC 50/60 Hz 150-F135NCD 150-F135NCDB 150-F135NCDD

    24V AC/DC 150-F135NCR 150-F135NCRB 150-F135NCRD

    67201 110 116348 160100...240V AC 50/60 Hz 150-F201NCD 150-F201NCDB 150-F201NCDD

    24V AC/DC 150-F201NCR 150-F201NCRB 150-F201NCRD

    84251 132 145435 250100...240V AC 50/60 Hz 150-F251NCD 150-F251NCDB 150-F251NCDD

    24V AC/DC 150-F251NCR 150-F251NCRB 150-F251NCRD

    106317 160 183549 135100...240V AC 50/60 Hz 150-F317NCD 150-F317NCDB 150-F317NCDD

    24V AC/DC 150-F317NCR 150-F317NCRB 150-F317NCRD

    120361 200 208625 355100...240V AC 50/60 Hz 150-F361NCD 150-F361NCDB 150-F361NCDD

    24V AC/DC 150-F361NCR 150-F361NCRB 150-F361NCRD

    160480 250 277831 450100...240V AC 50/60 Hz 150-F480NCD 150-F480NCDB 150-F480NCDD

    24V AC/DC 150-F480NCR 150-F480NCRB 150-F480NCRD

    208625 355 283850 500110/120V AC 50/60 Hz 150-F625NCE 150-F625NCEB 150-F625NCED230/240V AC 50/60 Hz 150-F625NCA 150-F625NCAB 150-F625NCAD

    260780 450 300900 500110/120V AC 50/60 Hz 150-F780NCE 150-F780NCEB 150-F780NCED

    230/240V AC 50/60 Hz 150-F780NCA 150-F780NCAB 150-F780NCAD

    323...970 560 4001200 710110/120V AC 50/60 Hz 150-F970NCE 150-F970NCEB 150-F970NCED

    230/240V AC 50/60 Hz 150-F970NCA 150-F970NCAB 150-F970NCAD

    4161250 710 5331600 900110/120V AC 50/60 Hz 150-F1250NCE 150-F1250NCEB 150-F1250NCED

    230/240V AC 50/60 Hz 150-F1250NCA 150-F1250NCAB 150-F1250NCAD

    Options Voltage Range

    D 100240V AC (5...480A units)R 24 V AC/DC (5...480A units)E 110/120V AC (625...1250A units)

    A 230/240V AC (625...1250A units)

    Options Voltage RangeB Up to 480V AC

    C Up to 600V AC

    Z Up to 690V AC,Options Description

    Blank Standard

    BPump Control

    Provides smooth motor acceleration and deceleration,reducing surges caused by the starting and stopping

    of centrifugal pumps. Starting time is adjustablefrom 030 seconds, and stopping time is

    adjustable from 0120 seconds.

    DBraking Control

    Provides Smart Motor Braking (SMB), Accu-Stop,

    and Slow Speed with Braking. Prices on request.

    Controllers rated 108 A and greater are not equipped with line and load terminal lugs.? Motor FLA and Motor Running Current must fall within the running current range of the device to operate properly. Utilization category: 5...480A AC-53b: 3-50: 1750 Separate 120V or 240V single phase is required for fan operation.

    625...1250A AC-53b: 3-50: 3550

    , For controllers rated 108...1250A only

    Optional Configurations 150-F108N B D B

    a b c

    a

    b

    c

  • 7/31/2019 Dolsmc Sg001 en p

    18/3216

    Description Cat. No.

    Protective Modules 1

    480V Protective Module585 A 150-F84

    1081250 A 150-F84L

    600V Protective Module585 A 150-F86

    1081250 A 150-F86L

    IEC Terminal Covers ?

    Terminal CoverIEC line or load terminal covers for 108...135 A devices.Dead front protection

    150-TC1

    Terminal CoverIEC line or load terminal covers for 201251 A devices.Dead front protection

    150-TC2

    Terminal CoverIEC line or load terminal covers for 317480 A devices.Dead front protection

    150-TC3

    Human Interface Modules

    Hand HeldHuman Interface Modules

    LCD Display,Full Numeric Keypad

    20-HIM-A3

    LCD Display,Programmer Only HIM

    20-HIM-A5

    Door MountedHuman Interface Modules

    LCD Display,Full Numeric Keypad(includes 3 m cable)

    20-HIM-C3S

    Human Interface ModuleInterface Cables

    HIM Interface Cable,1 m (39 in.)

    20-HIM-H10

    Communication Modules

    Communication Modules (IP30/Type 1)

    Remote I/O 20-COMM-R

    RS-485/DF1 20-COMM-S

    ProfiBUS 20-COMM-P

    ControlNet 20-COMM-C

    Interbus 20-COMM-I

    DeviceNet 20-COMM-D

    Ethernet/IP 20-COMM-E

    RS-485 HVAC 20-COMM-H

    ControlNet (Fiber) 20-COMM-Q

    Core Balance Transformer

    Core Balance Ground Fault Sensor 100:1 825-CBCT

    1 The same protective module mounts on the line or load side of the SMC-Flex. For applications requiring both line and load side protection, two protective modules must be ordered.

    ? One terminal cover is shipped as standard with the SMC-Flex controllers.

    Requires a 20-HIM-H10 cable to connect to the SMC-Flex.Discount Schedule SOF (150-), Discount Schedule 23 (20-), Discount Schedule MPC (825-CBCT)

  • 7/31/2019 Dolsmc Sg001 en p

    19/3217

  • 7/31/2019 Dolsmc Sg001 en p

    20/3218

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC

    50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    0.241.2 0.37 280D-F12Z-10A-CR 280A-F12Z-10A-CR 280D-F12B-10A-CR 280A-F12B-10A-CR

    0.52.5 0.75 280D-F12Z-10B-CR 280A-F12Z-10B-CR 280D-F12B-10B-CR 280A-F12B-10B-CR

    1.15.5 2.2 280D-F12Z-10C-CR 280A-F12Z-10C-CR 280D-F12B-10C-CR 280A-F12B-10C-CR

    3.216 7.5 280D-F23Z-25D-CR 280A-F23Z-25D-CR 280D-F23B-25D-CR 280A-F23B-25D-CR

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC

    50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    0.241.2 0.37 280D-S12Z-10A-CR 280A-S12Z-10A-CR 280D-S12B-10A-CR 280A-S12B-10A-CR

    0.52.5 0.75 280D-S12Z-10B-CR 280A-S12Z-10B-CR 280D-S12B-10B-CR 280A-S12B-10B-CR

    1.15.5 2.2 280D-S12Z-10C-CR 280A-S12Z-10C-CR 280D-S12B-10C-CR 280A-S12B-10C-CR

    3.216 7.5 280D-S23Z-25D-CR 280A-S23Z-25D-CR 280D-S23B-25D-CR 280A-S23B-25D-CR

    Bulletin 280/281

    On-Machine starting solution

    Full-Voltage DOL and reversing starting

    Modular plug and play design

    Quick disconnect connections for I/O, communications,

    three phase motor connection and control power

    Gland plate entry: conduit entrance or ArmorConnect power media

    4 Inputs and 2 Outputs (expandable with ArmorPoint)

    LED status indication

    DeviceNet communications

    DeviceLogix component technology

    Connectivity to ArmorPoint distributed I/O products

    ControlNet and EtherNet communications via ArmorPoint

    Factory Installed Options:- Hand/Off/Auto (HOA) keypad configuration- Safety monitor

    Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    for harsh production environmentsConduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:

    Replace -CRat the end of the Cat. No. with -RR(Example: 280D-S23Z-25D-RR)

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:Replace -CRat the end of the Cat. No. with -RR(Example: 280D-F23Z-25D-RR)

    ARMORSTART

  • 7/31/2019 Dolsmc Sg001 en p

    21/3219

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC

    50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    0.241.2 0.37 281D-F12Z-10A-CR 281A-F12Z-10A-CR 281D-F12B-10A-CR 281A-F12B-10A-CR0.52.5 0.75 281D-F12Z-10B-CR 281A-F12Z-10B-CR 281D-F12B-10B-CR 281A-F12B-10B-CR

    1.15.5 2.2 281D-F12Z-10C-CR 281A-F12Z-10C-CR 281D-F12B-10C-CR 281A-F12B-10C-CR

    3.216 7.5 281D-F23Z-25D-CR 281A-F23Z-25D-CR 281D-F23B-25D-CR 281A-F23B-25D-CR

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC

    50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    0.241.2 0.37 281D-S12Z-10A-CR 281A-S12Z-10A-CR 281D-S12B-10A-CR 281A-S12B-10A-CR

    0.52.5 0.75 281D-S12Z-10B-CR 281A-S12Z-10B-CR 281D-S12B-10B-CR 281A-S12B-10B-CR

    1.15.5 2.2 281D-S12Z-10C-CR 281A-S12Z-10C-CR 281D-S12B-10C-CR 281A-S12B-10C-CR

    3.216 7.5 281D-S23Z-25D-CR 281A-S23Z-25D-CR 281D-S23B-25D-CR 281A-S23B-25D-CR

    DescriptionCat. No.

    Modification

    Hand Off-Auto Selector Keypad -3 Example: 281D-S23Z-25D-RR-3

    Hand Off-Auto Selector Keypadwith Forward/Reverse Function

    -3FR Example: 281D-S23Z-25D-RR-3FR

    Safety Monitor -SM Example: 281D-S23Z-25D-RR-3FR-SM

    Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    for harsh production environmentsConduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:Replace -CRat the end of the Cat. No. with -RR(Example: 281D-F23Z-25D-RR)

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:

    Replace -CRat the end of the Cat. No. with -RR(Example: 281D-S23Z-25D-RR)

    For factory installed options, please contact your local sales office.

    Other ArmorStart versions available.Please consult publication 280-SG001_-EN-P for complete product information.

  • 7/31/2019 Dolsmc Sg001 en p

    22/3220

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    1.1...3.0 1.1 283D-FB3Z-10A-CR 283A-FB3Z-10A-CR 283D-FB3B-10A-CR 283A-FB3B-10A-CR

    3.0...5.5 2,2 283D-FB9Z-10B-CR 283A-FB9Z-10B-CR 283D-FB9B-10B-CR 283A-FB9B-10B-CR

    5.5...7.6 3.0 283D-FB16Z-10C-CR 283A-FB16Z-10C-CR 283D-FB16B-10C-CR 283A-FB16B-10C-CR

    6.316 5.5 283D-FB19Z-25D-CR 283A-FB19Z-25D-CR 283D-FB19B-25D-CR 283A-FB19B-25D-CR

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    1.1...3.0 1.1 283D-SB3Z-10A-CR 283A-SB3Z-10A-CR 283D-SB3B-10A-CR 283A-SB3B-10A-CR

    3.0...5.5 2,2 283D-SB9Z-10B-CR 283A-SB9Z-10B-CR 283D-SB9B-10B-CR 283A-SB9B-10B-CR

    5.5...7.6 3.0 283D-SB16Z-10C-CR 283A-SB16Z-10C-CR 283D-SB16B-10C-CR 283A-SB16B-10C-CR

    6.316 5.5 283D-SB19Z-25D-CR 283A-SB19Z-25D-CR 283D-SB19B-25D-CR 283A-SB19B-25D-CR

    Bulletin 283 On-Machine starting solution

    Soft Start motor control

    Modular plug and play design

    Quick disconnect connections for I/O, communications,

    three phase motor connection and control power

    Gland plate entry: conduit entrance or ArmorConnect power media

    4 inputs and 2 outputs (expandable with ArmorPoint)

    LED status indication

    DeviceNet communications

    DeviceLogix component technology

    Connectivity to ArmorPoint distributed I/O products

    ControlNet and EtherNet communications via ArmorPoint

    Factory Installed Options:- Hand/Off/Auto (HOA) keypad configuration

    - Source brake contactor- Safety monitor

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:Replace -CRat the end of the Cat. No. with -RR (Example: 283D-FB19Z-25D-RR)

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:

    Replace -CRat the end of the Cat. No. with -RR(Example: 283D-SB19Z-25D-RR)

    Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    for harsh production environmentsConduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    ARMORSTART

  • 7/31/2019 Dolsmc Sg001 en p

    23/3221

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC

    50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPoint

    CommunicationsCat. No.

    1.1...3.0 1.1 283D-FC3Z-10A-CR 283A-FC3Z-10A-CR 283D-FC3B-10A-CR 283A-FC3B-10A-CR3.0...5.5 2,2 283D-FC9Z-10B-CR 283A-FC9Z-10B-CR 283D-FC9B-10B-CR 283A-FC9B-10B-CR

    5.5...7.6 3.0 283D-FC16Z-10C-CR 283A-FC16Z-10C-CR 283D-FC16B-10C-CR 283A-FC16B-10C-CR

    6.316 5.5 283D-FC19Z-25D-CR 283A-FC19Z-25D-CR 283D-FC19B-25D-CR 283A-FC19B-25D-CR

    Current RatingMax.

    Motor Power24V DC

    Control Voltage240V AC

    Control Voltage

    [A]

    [kW]400V AC50 Hz

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    DeviceNetTM

    CommunicationsCat. No.

    ArmorPointCommunications

    Cat. No.

    1.1...3.0 1.1 283D-SC3Z-10A-CR 283A-SC3Z-10A-CR 283D-SC3B-10A-CR 283A-SC3B-10A-CR

    3.0...5.5 2,2 283D-SC9Z-10B-CR 283A-SC9Z-10B-CR 283D-SC9B-10B-CR 283A-SC9B-10B-CR

    5.5...7.6 3.0 283D-SC16Z-10C-CR 283A-SC16Z-10C-CR 283D-SC16B-10C-CR 283A-SC16B-10C-CR

    6.316 5.5 283D-SC19Z-25D-CR 283A-SC19Z-25D-CR 283D-SC19B-25D-CR 283A-SC19B-25D-CR

    DescriptionCat. No.

    Modification

    Hand Off-Auto Selector Keypad -3 Example: 283D-SC19Z-25D-RR-3

    Source Brake Contactor -SB Example: 283D-SC19Z-25D-RR-3-SB

    Safety Monitor -SM Example: 283D-SC19Z-25D-RR-3-SB-SM

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:Replace -CRat the end of the Cat. No. with -RR(Example: 283D-FC19Z-25D-RR)

    Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:

    Replace -CRat the end of the Cat. No. with -RR(Example: 283D-SC19Z-25D-RR)

    Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    for harsh production environmentsConduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    For factory installed options, please contact your local sales office.

    Other ArmorStart versions available.Please consult publication 280-SG001_-EN-P for complete product information.

  • 7/31/2019 Dolsmc Sg001 en p

    24/3222

    Input VoltageOutput Current

    [A]3-Phase Rating

    [kW]

    24V DCControl Voltage

    240V ACControl Voltage

    Cat. No. Cat. No.

    200...240V, 50/60 Hz3-Phase

    2.3 0.4 284D-FVB2P3Z-10-CR-EMI 284D-FVB2P3B-10-CR-EMI

    5 0.75 284D-FVB5P0Z-10-CR-EMI 284D-FVB5P0B-10-CR-EMI

    7.6 1.5 284D-FVB7P6Z-25-CR-EMI 284D-FVB7P6B-25-CR-EMI

    380...480V, 50/60 Hz3-Phase

    1.4 0.4 284D-FVD1P4Z-10-CR-EMI 284D-FVD1P4B-10-CR-EMI

    2.3 0.75 284D-FVD2P3Z-10-CR-EMI 284D-FVD2P3B-10-CR-EMI

    4 1.5 284D-FVD4P0Z-10-CR-EM 284D-FVD4P0B-10-CR-EMI

    6 2.2 284D-FVD6P0Z-25-CR-EMI 284D-FVD6P0B-25-CR-EMI

    7.6 3 284D-FVD7P6Z-25-CR-EMI 284D-FVD7P6B-25-CR-EMI

    460600V, 50/60 Hz3-Phase

    1.7 0.75 284D-FVE1P7Z-10-CR-EMI 284D-FVE1P7B-10-CR-EMI

    3 1.5 284D-FVE3P0Z-10-CR-EMI 284D-FVE3P0B-10-CR-EMI

    4.2 2.2 284D-FVE4P2Z-25-CR-EMI 284D-FVE4P2B-25-CR-EMI

    6.1 4 284D-FVE6P6Z-25-CR-EMI 284D-FVE6P6B-25-CR-EMI

    Bulletin 284 On-Machine starting solution

    Variable frequency AC drive using PowerFlex technology

    Modular plug and play design

    Quick disconnect connections for I/O, communications,

    three phase motor connection and control power

    Gland plate entry: conduit entrance or ArmorConnect power media

    4 Inputs and 2 Outputs (expandable with ArmorPoint)

    LED status indication

    DeviceNet communications

    DeviceLogix component technology

    Connectivity to ArmorPoint distributed I/O products

    ControlNet and EtherNet communications via ArmorPoint

    Factory Installed Options:

    - Hand/Off/Auto (HOA) keypad configuration

    - EMI filter

    - Dynamic brake connector- Output contactor

    - Source brake contactor

    - Shielded motor cable

    - Safety monitor

    - 0...10V analog input

    Sensorless Vector Control and Volts per Hertz, with DeviceNet Communications,

    EMI-Filter, Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    Version with ArmorPoint Communications:Replace284Dat the beginning of the Cat. No. with 284A (Example: 284A-FVE6P6Z-25-CR-EMI)

    Version with Quick Disconnects for ArmorConnect Power Media for Control and 3-Phase Power:

    Replace -CRat the end of the Cat. No. with -RR(Example: 284D-FVE6P6Z-25-RR-EMI)

    ARMORSTART

  • 7/31/2019 Dolsmc Sg001 en p

    25/3223

    Input VoltageOutput Current

    [A]3-Phase Rating

    [kW]

    24V DCControl Voltage

    240V ACControl Voltage

    Cat. No. Cat. No.

    200...240V, 50/60 Hz

    3-Phase

    2.3 0.4 284D-SVB2P3Z-10-CR-EMI 284D-SVB2P3B-10-CR-EMI

    5 0.75 284D-SVB5P0Z-10-CR-EMI 284D-SVB5P0B-10-CR-EMI7.6 1.5 284D-SVB7P6Z-25-CR-EMI 284D-SVB7P6B-25-CR-EMI

    380...480V, 50/60 Hz3-Phase

    1.4 0.4 284D-SVD1P4Z-10-CR-EMI 284D-SVD1P4B-10-CR-EMI

    2.3 0.75 284D-SVD2P3Z-10-CR-EMI 284D-SVD2P3B-10-CR-EMI

    4 1.5 284D-SVD4P0Z-10-CR-EMI 284D-SVD4P0B-10-CR-EMI

    6 2.2 284D-SVD6P0Z-25-CR-EMI 284D-SVD6P0B-25-CR-EMI

    7.6 3 284D-SVD7P6Z-25-CR-EMI 284D-SVD7P6B-25-CR-EMI

    460600V, 50/60 Hz3-Phase

    1.7 0.75 284D-SVE1P7Z-10-CR-EMI 284D-SVE1P7B-10-CR-EMI

    3 1.5 284D-SVE3P0Z-10-CR-EMI 284D-SVE3P0B-10-CR-EMI

    4.2 2.2 284D-SVE4P2Z-25-CR-EMI 284D-SVE4P2B-25-CR-EMI

    6.1 4 284D-SVE6P6Z-25-CR-EMI 284D-SVE6P6B-25-CR-EMI

    DescriptionCat. No.

    Modification

    Hand Off-Auto Selector Keypadwith JOG Function

    -3 Example: 284D-SVE6P6Z-25-CR-3-EMI

    Control Brake Contactor -CB Example: 284D-SVE6P6Z-25-CR-3-CB-EMI

    Dynamic Brake Connector -DB Example: 284D-SVE6P6Z-25-CR-3-DB-EMI

    Source Brake Contactor -SB Example: 284D-SVE6P6Z-25-CR-3-SB-EMI

    0...10V Analog Input -A10 Example: 284D-SVE6P6Z-25-CR-3-SB-A10

    EMI Filter -EMI Example: 284D-SVE6P6Z-25-CR-3-SB-EMI

    Output Contactor -OC Example: 284D-SVE6P6Z-25-CR-3-SB-OC

    Safety Monitor -SM ? Example: 284D-SVE6P6Z-25-CR-3-SB-SM

    Sensorless Vector Control and Volts per Hertz, with DeviceNet Communications,EMI-Filter, Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

    Version with ArmorPoint Communications:Replace284Dat the beginning of the Cat. No. with 284A (Example: 284A-SVE6P6Z-25-CR-EMI)

    Version with Quick Disconnects for ArmorConnect Power Media for Control and 3-Phase Power:Replace -CRat the end of the Cat. No. with -RR(Example: 284D-SVE6P6Z-25-RR-EMI)

    ? The output contactor is included with the Safety Monitor option.

    For factory installed options, please contact your local sales office.

  • 7/31/2019 Dolsmc Sg001 en p

    26/3224

    Direct-Online Class 10

    Circuit Breaker 140M MCP (Magnetic Only)

    Contactor 100-C / 100-D

    Overload Relay E1Plus - 193-ED../193-EE..

    Rated Operational Voltage 400V 50Hz

    Rated Conditional S-C Current (Iq) 50kA (rms sym)

    Type of Coordination (IEC 947-4-1) Type "2"

    Motor Circuit Breaker Contactor Overload Relay

    1500 rpm[kW] [A] Type

    MagneticSetting

    [A] Type Type (1)

    ThermalSetting

    [A]

    0.06 0.24 140M-C2N-A25 3.3 100-C09 193-ED1AB 0.10 - 0.50

    0.09 0.33 140M-C2N-A40 5.2 100-C09 193-ED1AB 0.10 - 0.50

    0.12 0.43 140M-C2N-A63 8.2 100-C09 193-ED1AB 0.10 - 0.50

    0.18 0.61 140M-C2N-A63 8.2 100-C09 193-ED1BB 0.20 - 1.0

    0.25 0.80 140M-C2N-B10 13 100-C09 193-ED1BB 0.20 - 1.0

    0.37 1.1 140M-C2N-B16 20 100-C09 193-ED1CB 1.0 - 5.0

    0.55 1.5 140M-C2N-B16 20 100-C09 193-ED1CB 1.0 - 5.00.75 1.9 140M-C2N-B25 32 100-C09 193-ED1CB 1.0 - 5.0

    1.1 2.7 140M-D8N-B40 52 100-C09 193-ED1CB 1.0 - 5.0

    1.5 3.5 140M-D8N-B40 52 100-C09 193-ED1CB 1.0 - 5.0

    2.2 5.0 140M-D8N-B63 82 100-C09 193-ED1CB 1.0 - 5.0

    3 6.6 140M-D8N-C10 130 100-C09 193-ED1DB 3.2 - 16

    4 8.5 140M-D8N-C10 130 100-C09 193-ED1DB 3.2 - 16

    5.5 11 140M-D8N-C16 208 100-C12 193-ED1DB 3.2 - 16

    7.5 15 140M-D8N-C16 208 100-C16 193-ED1DB 3.2 - 16

    10 20 140M-D8N-C25 325 100-C23 193-EEED 5.4 - 27

    11 22 140M-D8N-C25 325 100-C23 193-EEED 5.4 - 27

    15 29 140M-F8N-C32 416 100-C30 193-EEFD 9 - 45

    18.5 36 140M-F8N-C45 585 100-C37 193-EEFD 9 - 45

    22 41 140M-F8N-C45 585 100-C43 193-EEFD 9 - 45

    30 56 140M-H8P-C70 210 - 770 100-C60 193-EEFD 9 - 45

    37 68 140M-H8P-C70 210 - 770 100-C72 193-EEGE 18 - 90

    45 81 140M-H8P-D10 300 - 1100 100-C85 193-EEGE 18 - 90

    55 99 140M-H8P-D10 300 - 1100 100-D210 193-EEJG 40 - 200

    75 135 140M-J8P-D20 1000 - 2000 100-D210 193-EEJG 40 - 200

    90 162 140M-J8P-D20 1000 - 2000 100-D210 193-EEJG 40 - 200

    110 196 140M-J8P-D20 1000 - 2000 100-D210 193-EEJG 40 - 200

    132 232 140M-J8P-D25 1250 - 2500 100-D250 193-EEKG 60 - 300

    160 281 140M-L8P-D30 1500 - 3000 100-D300 193-EEKG 60 - 300

    200 350 140M-L8P-D40 2000-4000 100-D420 193-EELG 100 - 500

    (1)Use of current ajustment shield 193-BC8 is recommended to prevent inadvertent adjustment of the current setting

    SHORT -

  • 7/31/2019 Dolsmc Sg001 en p

    27/3225

    Direct-Online Class 10

    Circuit Breaker 140M MCP (Magnetic Only)

    Contactor 100-C / 100-D

    Overload Relay E3 - 193-EC1 / 193-EC2

    Rated Operational Voltage 400V 50Hz

    Rated Conditional S-C Current (Iq) 50kA (rms sym)

    Type of Coordination (IEC 947-4-1) Type "2"

    Motor Circuit Breaker Contactor Overload Relay

    1500 rpm[kW] [A] Type

    MagneticSetting

    [A] Type Type (1) (2)

    ThermalSetting

    [A]

    0.06 0.24 140M-C2N-A25 3.3 100-C09 193-EC1PB 0.4 - 2.0

    0.09 0.33 140M-C2N-A40 5.2 100-C09 193-EC1PB 0.4 - 2.0

    0.12 0.43 140M-C2N-A63 8.2 100-C09 193-EC1PB 0.4 - 2.0

    0.18 0.61 140M-C2N-A63 8.2 100-C09 193-EC1PB 0.4 - 2.0

    0.25 0.80 140M-C2N-B10 13 100-C09 193-EC1PB 0.4 - 2.0

    0.37 1.1 140M-C2N-B16 20 100-C09 193-EC1PB 0.4 - 2.0

    0.55 1.5 140M-C2N-B16 20 100-C09 193-EC1PB 0.4 - 2.00.75 1.9 140M-C2N-B25 32 100-C09 193-EC1PB 0.4 - 2.0

    1.1 2.7 140M-D8N-B40 52 100-C09 193-EC1AB 1 - 5

    1.5 3.5 140M-D8N-B40 52 100-C09 193-EC1AB 1 - 5

    2.2 5.0 140M-D8N-B63 82 100-C09 193-EC1AB 1 - 5

    3 6.6 140M-D8N-C10 130 100-C09 193-EC1BB 3 - 15

    4 8.5 140M-D8N-C10 130 100-C09 193-EC1BB 3 - 15

    5.5 11 140M-D8N-C16 208 100-C12 193-EC1BB 3 - 15

    7.5 15 140M-D8N-C16 208 100-C16 193-EC1BB 3 - 15

    10 20 140M-D8N-C25 325 100-C23 193-EC1CB 5 - 25

    11 22 140M-D8N-C25 325 100-C23 193-EC1CB 5 - 25

    15 29 140M-F8N-C32 416 100-C30 193-EC1DD 9 - 45

    18.5 36 140M-F8N-C45 585 100-C37 193-EC1DD 9 - 4522 41 140M-F8N-C45 585 100-C43 193-EC1DD 9 - 45

    30 56 140M-H8P-C70 210 - 770 100-C60 193-EC1EE 18 - 90

    37 68 140M-H8P-C70 210 - 770 100-C72 193-EC1EE 18 - 90

    45 81 140M-H8P-D10 300 - 1100 100-C85 193-EC1EE 18 - 90

    55 99 140M-H8P-D10 300 - 1100 100-D110 193-EC1FF 28 - 140

    75 135 140M-J8P-D15 750 - 1500 100-D140 193-EC1FF 28 - 140

    90 162 140M-J8P-D20 1000 - 2000 100-D180 193-EC1GF 42 - 210

    110 196 140M-J8P-D20 1000 - 2000 100-D210 193-EC1GG 42 - 210

    132 232 140M-J8P-D25 1250 - 2500 100-D250 193-EC1HG 60 - 302

    160 281 140M-L8P-D30 1500 - 3000 100-D300 193-EC1HG 60 - 302

    200 350 140M-L8P-D40 2000-4000 100-D420 193-EC1JG 84 - 420

    (1)Use of current ajustment shield 193-BC8 is recommended to prevent inadvertent adjustment of the current setting (2)Overload Relay 193-EC2.. can also be used

    SHORT -

  • 7/31/2019 Dolsmc Sg001 en p

    28/3226

    Motor Protection 193-ED 193-EE 193-EC1 193-EC2 825-P SMC-3 SMC-FLEXOverload Underload Stall (1) Jam (1) Thermistor Input (1) Earth Fault Input (1) Phase loss

    Current Imbalance Short Circuit Phase Reversal Under Voltage (1) Over Voltage (1) Starts Per Hour 2 Speed Motor Stator RTD (1)

    Bearing RTD (1)

    Ambient RTD (1)

    Trip class 10 10...30 5...30 5...30 1...600 5...30Manual reset Automatic reset Single phase Three phase Warnings

    Fault History General FeaturesCommunication (1) Logic Functions Local display I/O Soft Starter ControlSoft Start Kick Start Curent Limit Dual ramp Start Full Voltage Soft Stop Pump Control Preset Slow Speed

    Linear Speed Braking Accu-Stop Slow Speed with Braking Suitable for inside the delta wiring Variable Speed ControlVariable SpeedFlying StartS - CurveProcess Control Loop (PIDFast Flux UpFast Brake to StopFlux BrakingSpeed ProfilesClose Loop Speed ControlClose Loop Torque Control

    P-jump (Traverse Function)Pump/Fan Application FunctionsLifting Application FunctionsWinder Application FunctionsElectronic Gearing/Line ShaftMotion Control FunctionsSafe-OffMechanical ProtectionOverall Vibration levelUnbalanceMisalignmentFlow problemsBearing DefectsMechanical LoosenessRubbingDrive Belt Problems

  • 7/31/2019 Dolsmc Sg001 en p

    29/3227

    PF4M PF4 PF40 PF40P PF400 PF70 PF700 PF700H PF700S XM-16X XM-12X

    NA NA NA NA NA NA NA NA NA

    regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated regulated

    no limits no limits no limits no limits no limits no limits no limits no limits no limitsNA NA NA NA NA NA NA NA NA

    variable variable variable variable variable variable variable variable variable

    (1)

    (1) (1) (1) (1)

    (1) (1) (1) (1)

    (1) (1)

    (1)

    (1)

    (1)

    (1)

    (1)

    (1)

    (1)

    (1)With add on Modules.

  • 7/31/2019 Dolsmc Sg001 en p

    30/3228

  • 7/31/2019 Dolsmc Sg001 en p

    31/3229

  • 7/31/2019 Dolsmc Sg001 en p

    32/32

    For More Information

    For more information about Rockwell Automation Services and Support go towww.rockwellautomation.com/services. To learn which other Rockwell Automation Services and

    Support will be most beneficial to your maintenance strategy, contact your local authorised Allen-Bradley distributor or Rockwell Automation sales office.

    PREDICT

    PR

    EVENT

    RE

    ACT

    Assessment Services

    Baseline evaluations of plant floor technical skills, procedures, equipment operation, spare parts inventory, risk,

    safety and security as well as other automation-related assessments.

    Condition Monitoring

    Predictive Maintenance products and services for rotating equipment.

    Asset Management Services

    Maintenance Repair Operations (MRO) process and Spare Parts Management for automation assets.

    Remote Support Services

    Real-time troubleshooting and monitoring* of automation equipment and systems by off-site automation

    specialists.

    Safety, Network & Security Services

    Network design and evaluation, security policy development/deployment, and machine safety services.

    Training Services

    Instructor-led training, self-paced training and competency testing on automation and related topics.

    OnSite Support Services

    Startup, troubleshooting, repair, conversions and Preventive Maintenance for automation equipment and

    systems by Rockwell Automation Field Support Engineers.

    Repair Services & Renewal Parts

    Remanufacturing and exchange services for automation products and

    build-to-order legacy automation products.

    *System monitoring not available at all service levels

    Rockwell Automation Services & Support