océ|messages guide

162
Océ Océ | Messages Guide OcØ PRISMAproduction Host CIS V4.04

Upload: khangminh22

Post on 21-Apr-2023

1 views

Category:

Documents


0 download

TRANSCRIPT

OcéOcé | Messages Guide

Océ PRISMAproduction HostCIS V4.04

Copyright © Océ Printing Systems GmbH 2004All rights reserved, including rights of translation, reprinting, reproduction by copying or any other method.Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserverd. Delivery subject to availability; right of technical modification reserved.All hardwware and software names used are trademarks of their respective owners.

January 2004 Edition

For this product we also offer seminars atour Training Center in Poing.

Information: Phone +49 8121 72-3990Fax +49 8121 72-3950

Océ Printing Systems GmbHPostfach 126085581 PoingGermany

...and Training?

A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

1 PRISMAproduction Host CIS MessagesThis manual documents the PRISMAproduction Host CIS messages. It provides an ex-panded explanation of the meaning of the messages and the resulting system actions. A suggested user response is provided too. The intended audience of this document is the end user or anyone responsible for maintenance or problem diagnosis of the PRISMApro-duction Host CIS product.

The PRISMAproduction Host CIS product makes use of the SAS/C® Run-time library V7.00. In some error conditions, it could be that a CIS job displays error messages issued by this run-time environment. The description and explanation of these messages is includ-ed in the SAS/C® Software Diagnostic Messages, Release 7.00 manual. This publication is available online in Internet under:

http://support.sas.com/documentation/onlinedoc/sasc/doc700

A29247-X16-X-2-7674 1

PRISMAproduction Host CIS Messages

CIS00010E Error occurred during processing

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00020E Invalid program argument(s) syntax

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

2 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS00030E Unable to open licence file &01.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS00040E Wrong licence key. Please contact your Oce System Engineer.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation CIS did not found a valid licence key in licence file.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS00050I Install Software-Licence for MAC-Address(es) &01.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation Display MAC adresses of current machine in case of licence check has failed.

A29247-X16-X-2-7674 3

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS00060I Key word \"&01\" exceeds licence feature rights (&02).

Inserts: &01: general character string&02: general integer value

&03: < not used >&04: < not used >

Explanation Licence checker denies usage of key word displayed. The key word is not part of a features group allowed by licence.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS00070I Install Software-Licence for CPU-identifier &01.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation Display CPU identifier of current machine in case of licence check has failed.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

4 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS00071W Trace service initialization failed, tracing unavailable.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: <not used >

Explanation: Something went wrong with trace facility during initialization. Most common reason under MVS is lacking tracedd statement in paramenter file. Process-ing continues without tracing.

CIS-Action: Message is issued. Processing continues.

User Response: None.

CIS00080I Above mentioned error ocurred at block <&01> of &02

Inserts: &01: relative block number&02: PDS | RDS

&03: < not used >&04: < not used >

Explanation This message shows the relative block number where the error was detect-ed and the type of input data stream that was being processed. The input data stream may be PDS (Primary Data Stream) when the error was detect-ed within the print document or an Inline Resource stored with the print doc-ument, or RDS (Resource Data Stream) when the error ocurred within an external resource file.

CIS Action: Processing of the "Error Localization Messages" continues until all localiza-tion messages are issued.The System Action is determined by the error message preceeding the lo-calization messages.

User Response: Please refer to the User Action of the last message preceeding the "Error Localization Messages".

A29247-X16-X-2-7674 5

PRISMAproduction Host CIS Messages

CIS00090I active &01 &02 is <&03>

Inserts: &01: AFP object type&02: <variable data>

&03: <variable data>&04: < not used >

Explanation This message shows the AFP object where the error was found.&01 may be: "Structured field", "Data Map", "Medium Map", "input Page", "input Page Group", "Document", "PDS", "Form Definition", "Page Defini-tion", "Overlay", "Page Segment", "Coded Font", "Font Character Set", "Code Page", "AFP object".&02 may be: "mnemonic", "(internal name)", "(external name)", "number", " " (blank string).&03 may be: mnemonic value, name value, number, PDS token, RDS token.

CIS Action: Processing of the "Error Localization Messages" continues until all localiza-tion messages are issued.The System Action is determined by the error message preceeding the lo-calization messages.

User Response: Please refer to the User Action of the last message preceeding the "Error Localization Messages".

CIS00100I active &01 &02 is <&03, &04>

Inserts: &01: AFP object type&02: <variable data>

&03: <variable data>&04: <variable data>

Explanation This message shows the AFP object where the error was found.&01 may be: "Structured field", "Data Map", "Medium Map", "input Page", "input Page Group", "Document", "PDS", "Form Definition", "Page Defini-tion", "Overlay", "Page Segment", "Coded Font", "Font Character Set", "Code Page", "AFP object".&02 may be: "mnemonic", "(internal name)", "(external name)", "number", " " (blank string).&03 may be: mnemonic value, name value, number, PDS token, RDS token.&04 same as &03 but in hexadecimal format.

6 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Processing of the "Error Localization Messages" continues until all localiza-tion messages are issued.The System Action is determined by the error message preceeding the lo-calization messages.

User Response: Please refer to the User Action of the last message preceeding the "Error Localization Messages".

CIS00110W The 'OVLid' parameter <&01> is out of range

Inserts: &01: Overlay Identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation A Medium Overlay local Identifier in a MMO structured field is out of range. It should be 1 to 127.The MMO structured field is part of a Medium Map, which may be part of a Formdef (inline or external), or may be stored inline.

CIS Action: The resource or field in error is ignored. Processing continues. Subsequent errors are possible.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00120E Invalid resource local identifier parameter <&01>

Inserts: &01: Resource local identifier&02: < not used >

&03: < not used >&04: < not used >

A29247-X16-X-2-7674 7

PRISMAproduction Host CIS Messages

Explanation The resource local Identifier can be specified in a MCF, MMO or MPO struc-tured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00130E Duplicate resource local identifier <&01> detected

Inserts: &01: Resource local identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation The resource local Identifier can be specified in a MCF or MMO structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00140W The 'SUPid' parameter <&01> is out of range

Inserts: &01: Text suppression local identifier&02: < not used >

&03: < not used >&04: < not used >

8 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation A text suppresion local Identifier in a MSU structured field is out of range. It should be 1 to 127.

CIS Action: The resource or field in error is ignored. Processing continues. Subsequent errors are possible.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00150E More than <&01> text suppressions defined

Inserts: &01: Number of text suppressions&02: Text suppression name (hex)

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00160E Duplicate text suppression name <&01, &02> detected

Inserts: &01: Text suppression name (text)&02: Text suppression name (hex)

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 9

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00170E Invalid 'MFCScpe' parameter <&01>

Inserts: &01: MFC Scope&02: < not used >

&03: < not used >&04: < not used >

Explanation valid value are X-01 to X-05

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00180W Unexpected 'MFCScpe' parameter <&01>

Inserts: &01: MFC Scope&02: < not used >

&03: < not used >&04: < not used >

Explanation Expected value are X-01 to X-03 for Document Environment Groupand and X-04 to X-05 for Medium Map

10 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00190E Invalid 'MedColl' parameter <&01>

Inserts: &01: Boundary condition for medium-map-level sheet collection&02: < not used >

&03: < not used >&04: < not used >

Explanation Valid value are X-01 to X-02 if MFC Scope = X-05

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00200W Unknown 'FOpType' parameter <&01>

Inserts: &01: Finishing operation type&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: None.

A29247-X16-X-2-7674 11

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00210E Invalid 'RefEdge' parameter <&01>

Inserts: &01: Finishing operation reference corner or edge&02: < not used >

&03: < not used >&04: < not used >

Explanation Valid value for Finishing operation reference corner or edge are X-00 to X-03 and X-FF

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00220E Mismatch between 'FOpCnt' parameter <&01> and number of 'OpPos' parameter <&02>

Inserts: &01: Finishing operation count&02: Operation position on finishing operation axis

&03: < not used >&04: < not used >

Explanation The Finishing Operation Count is none-zero but dones not math the number of Operation Position specified in triplet X-85 or in triplet X-8E.

12 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00230E More than 8 overlays are specified in MMC structured field

Inserts: &01: MMC identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00240E More than 8 suppresions are specified in a MMC structured filed

Inserts: &01: MMC identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 13

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00250E Overlay local identifier <&01> specified in MMC structured field but not found in MMO structured field

Inserts: &01: Overlay Identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00260E 'MMCid' parameter <&01> mismatch detected

Inserts: &01: MMC identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation The identifier in a Medium Modification Control structured field must corre-spond to a value specified in a Medium Copy Count structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

14 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00270E Incorrect 'MMCid' parameter <&01> detected

Inserts: &01: MMC identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation The identifier in a Medium Modification Control structured field is either not unique or is not in ascending order.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00280E Invalid Offset Stacking parameter <&01>

Inserts: &01: Offset stacking value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 15

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00290E Mismatch Media Source in MMC duplex pair

Inserts: &01: Offset stacking value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00300E Invalid 'Startnum' parameter <&01> in first copy group

Inserts: &01: Copy Number&02: < not used >

&03: < not used >&04: < not used >

Explanation The starting page number of the first copy group is not 1.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

16 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00310E Invalid combination of 'Startnum' <&01> and 'Stopnum' <&02> param-eters

Inserts: &01: Copy Number&02: Copy Number

&03: < not used >&04: < not used >

Explanation The difference between the ending copy number and the starting copy num-ber cannot exceed 255.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00320E Invalid page orientation parameter <&01>

Inserts: &01: Orientation value&02: Copy Number

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 17

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00330E No partition with variable page data defined

Inserts: &01: Orientation value&02: Copy Number

&03: < not used >&04: < not used >

Explanation The presentation control parameters 'PgFlgs' in all repeating groups of the PGP structured field are specified do not present variable page data.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00340E The PGP Structured field is not specified in Medium Map

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The PGP structured field should be specified in either the documen environ-ment group or a medium map.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

18 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00350E The MDD Structured field is not specified in Medium Map

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The MDD structured field should be specified in either the documen environ-ment group or a medium map.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00360I Invalid Medium Orientation parameter <&01>

Inserts: &01: Orientation value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The parameter in error is ignored and PORTRAIT is assumed. Processing continues.

A29247-X16-X-2-7674 19

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00370E Invalid 'PMCid' parameter <&01> detected

Inserts: &01: PMC identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation valid value are X-00 - X7F

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00380W Invalid combination of 'Constant forms control' and 'N-up format con-trol' parameters in MMC structured field

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation A Medium Modification Control structured field specifies Constant forms control at a time where N-Up format control is also being used. This is not allowed.

CIS Action: The 'Constant forms control' parameter is ignored. Processing continues.

20 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00390I Invalid 'N-up format control' parameter <&01>

Inserts: &01: N-up value&02: < not used >

&03: < not used >&04: < not used >

Explanation The Medium Modification Control structured field specifies an N-Up param-eter value which is invalid.

CIS Action: The 'N-up format control' parameter is ignored and ONE-UP is assumed. Processing continues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00400E Invalid combination of 'X2-up control' and 'N-up format control' param-eters

Inserts: &01: Orientation value&02: Copy Number

&03: < not used >&04: < not used >

Explanation X2_up control is specified in MDD structured field or in paramter file. N-up control in MMC structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 21

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00410E The second IMM structured field following the constant data page is missing

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Immediately following the IMM structured field to select a Medium Map, which specifieds constanst front and simplex or constant both, must be a second IMM to return to a Medium Map for the next portion of the data.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00420E DUPLEX keyword not supported for formdef with enhanced N-up

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation DUPLEX ( SIMPLEX) is specified in paramter file. And enhance N-up is specified in PGP structured field. The converting duplex to simplex with en-hanced nup is not supported.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

22 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Check your print job parameters.

CIS00430E Too many medium map found during converting of duplex formdef to simplex

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation DUPLEX ( SIMPLEX) is specified in paramter file.The number of medium map exceeds the number of medium map name for the converting of duplex formdef to simplex. The maximum number of medium maps supported by CIS is 65535.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00440E Mismatch between number of repeating groups in PGP structured field <&01> and N-UP equal <&02>

Inserts: &01: Number of repeating groups&02: N-up value

&03: < not used >&04: < not used >

Explanation If explicit N-up page placement is specified, the PGP structured field should contain N repeating groups for simplex printing, and 2N repeating groups for duplex printing. N-up value is specified in MMC structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 23

PRISMAproduction Host CIS Messages

User Response: Check your print job parameters.

CIS00450E DUPLEX (SIMPLEX) keyword not supported for a duplex Medium Map containing constant form control for both side

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00460E Too many medium map found during consolidating of formdef

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The number of medium map exceeds the number of medium map name for the consolidating formdef. The maximum number of medium maps support-ed by CIS is 65535.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

24 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS00470E Too many text suppressions found during consolidating of formdef

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The maximum number of text suppressions is 127.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00480E Unsupport MFCScpe = print-file-level when resource consolidation is specified

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation MFCScpe is specified in Strutrured field MFC in a formdef.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00490E Invalid Unit_Base parameter <&01, &02> detected

Inserts: &01: Units base in X direction&02: Units base in Y direction

&03: Structured field name&04: < not used >

A29247-X16-X-2-7674 25

PRISMAproduction Host CIS Messages

Explanation An invalid or conflictive Unit base value was found while processing a struc-tured field. When defining measurement bases, the base must be the same for the two directions.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00500E Invalid Units_per_Unit_Base parameter <&01, &02> detected

Inserts: &01: Units per unit base in X direction&02: Units per unit base in Y direction

&03: Structured field name&04: < not used >

Explanation An invalid or conflictive Units per unit base value was found while process-ing a structured field. When defining measurement bases, the base must be the same for the two directions.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00510E Invalid 'TSvCtrl' parameter <&01> in Toner Saver Triplet

Inserts: &01: Toner Saver Control value&02: < not used >

&03: < not used >&04: < not used >

26 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation valid value are X-00, X-01 and X-FF

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00520E Invalid 'StpCoEx' parameter <&01> in Color Fidelity Triplet

Inserts: &01: Value for exception parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00530E Invalid 'RepCoEx' parameter <&01> in Color Fidelity Triplet

Inserts: &01: Value for the exception report parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

A29247-X16-X-2-7674 27

PRISMAproduction Host CIS Messages

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00540E Invalid 'StpFntEx' parameter <&01> in Font Fidelity Triplet

Inserts: &01: Value for exception parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00550E Invalid 'StpMedEx' parameter <&01> in Media Fidelity Triplet

Inserts: &01: Value for exception parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

28 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00560E Invalid 'StpFinEx' parameter <&01> in Finishing Fidelity Triplet

Inserts: &01: Value for exception parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00570E Invalid 'RepFinEx' parameter <&01> in Finishing Fidelity Triplet

Inserts: &01: Value for the exception report parameter in a fidelity triplet&02: < not used >

&03: < not used >&04: < not used >

A29247-X16-X-2-7674 29

PRISMAproduction Host CIS Messages

Explanation valid value are X-01 and X-02

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00580E Invalid 'NLNDskp' parameter <&01>

Inserts: &01: Next_Line_Descriptor value&02: LND number

&03: < not used >&04: < not used >

Explanation The "Next Line Descriptor if Skipping" parameter in an LND structured field is either zero or bigger than the LNC count value.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00590E Invalid 'NLNDsp' parameter <&01>

Inserts: &01: Next_Line_Descriptor value&02: LND number

&03: < not used >&04: < not used >

30 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation The "Next Line Descriptor if Spacing" parameter in an LND structured field is either zero or bigger than the LNC count value.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00600E Invalid 'NLNDreu' parameter <&01>

Inserts: &01: Next_Line_Descriptor value&02: LND number

&03: < not used >&04: < not used >

Explanation The "Next Line Descriptor if Reusing Data" parameter in an LND structured field is either zero or bigger than the LNC count value.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00610W Invalid combination of 'DataStrt' <&01> and 'DataLgth' <&02> parame-ters

Inserts: &01: LND DataStrt parameter&02: LND DataLgth parameter

&03: LND number&04: < not used >

A29247-X16-X-2-7674 31

PRISMAproduction Host CIS Messages

Explanation The "Data Start Position" and "Data Length" parameters in an LND struc-tured field cannot exceed the value specified in the "Size" parameter of the FDS structured field.

CIS Action: The resource or field in error is ignored. Processing continues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00620W 'DataLgth' parameter mismatch between LND <&01> and FDX <&02> structured fields

Inserts: &01: LND DataLgth parameter&02: FDX length of 'Text' parameter

&03: LND number&04: < not used >

Explanation The amount of fixed data to be used specified in the "Data Length" parame-ter in an LND structured field may not exceed the length of the "Text" param-eter of the FDX structured field.

CIS Action: The actual text length from the FDX structured field is used. Processing con-tinues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00630W Mismatch between FDX 'Text' length <&01> and FDS 'TxtLgth' <&02> parameters

Inserts: &01: FDX length of 'Text' parameter&02: FDS TxtLgth parameter

&03: < not used >&04: < not used >

32 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation The total number of fixed data bytes in the FDX structured field does not match the number of bytes specified in the FDS structured field.

CIS Action: The actual text length from the FDX structured field is used. Processing con-tinues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00640W Invalid 'Skip_to_channel' parameter <&01> detected

Inserts: &01: Skip_to_channel parameter&02: < not used >

&03: < not used >&04: < not used >

Explanation The Carriage Control of the input line data contains a spacing channel code which is not defined in the Data Map currently active.

CIS Action: The 'Skip_to_channel' parameter is ignored and the position of the first LND is used. Processing continues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00650E TRC not supported for Record Format Line Data

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

A29247-X16-X-2-7674 33

PRISMAproduction Host CIS Messages

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00660E 'RecID' <&01> could not be found in the active Data Map

Inserts: &01: Record Descriptor ID&02: < not used >

&03: < not used >&04: < not used >

Explanation The Record Descriptor of the input line data is not defined in the Data Map currently active.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00670E Infinite loop in 'NLNDskp' parameter

Inserts: &01: LND number&02: < not used >

&03: < not used >&04: < not used >

Explanation The "Next Line Descriptor if Skipping" parameter in an LND structured field caused an infinite loop condition.

34 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00680E Infinite loop in 'NLNDsp' parameter

Inserts: &01: LND number&02: < not used >

&03: < not used >&04: < not used >

Explanation The "Next Line Descriptor if Spacing" parameter in an LND structured field caused an infinite loop condition.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00690E Duplicate 'RecID' <&01> detected

Inserts: &01: Record Descriptor ID&02: < not used >

&03: < not used >&04: < not used >

Explanation The "Record Descriptor ID" parameter in a RCD structured field is repeated in the Data Map.

A29247-X16-X-2-7674 35

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00700E Invalid 'FLDrcd' parameter <&01>

Inserts: &01: RCD Number&02: < not used >

&03: < not used >&04: < not used >

Explanation The "Field RCD Pointer" parameter in an RCD structured field is bigger than the LNC count value.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00710E Invalid 'CONDrcd' parameter <&01>

Inserts: &01: RCD Number&02: < not used >

&03: < not used >&04: < not used >

Explanation The "Conditional Processing RCD Pointer" parameter in an RCD structured field is bigger than the LNC count value.

36 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00720E Invalid combination of 'RCDFlgs bit 6' and 'RCDFlgs bit 11'

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation A RCD can not be a Field RCD and also be a Conditional Processing RCD.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00730E 'Align' parameter is 01 but 'FntLID' parameter is X'FF'

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation A Font should be specified if right alignment is used. The font information is necessary for the processing

A29247-X16-X-2-7674 37

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00740E More than one Default Page Header RCD specified in a Data Map

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00750E More than one Default Page Trailer RCD specified in a Data Map

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

38 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00760E Mismatch between number of LND/RCD structured fields <&01> and 'NumLND' parameter <&02> in LNC structured field

Inserts: &01: number of LNDs or RCDs in DataMap&02: LNC NumLND parameter

&03: < not used >&04: < not used >

Explanation The total number of Line Descriptor or Record Descriptor structured fields must match the value specified in the Line Descriptor Count structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00770E Pagedef required but not specified

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Processing of Line format data requires a Pagedef resource which was not specified.

A29247-X16-X-2-7674 39

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that a PAGEDEF name is specified when printing Line format data.

CIS00780E Mismatch Data Map format in a Page Definition

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation All Data Maps in a Page Definition must specify the same format which is either traditional line data using structured field LNDs or record-format line data using RCDs.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that a PAGEDEF name is specified when printing Line format data.

CIS00790E Formdef required but not specified

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The Formdef resource was not specified. Either an External Resource Group (inline Resource) was not ocurred in the print data, or there is any formdef existed in the External Resource Group.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

40 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Check your print job parameters.

CIS00800E No Medium Map specified in Formdef

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS00810E Invalid 'PatTech' parameter <&01>

Inserts: &01: Pattern Technology Identifier&02: < not used >

&03: < not used >&04: < not used >

Explanation The Pattern Technology Identifier in a FNC structured field must be 0x05, 0x1E or 0x1F.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

A29247-X16-X-2-7674 41

PRISMAproduction Host CIS Messages

CIS00820E Invalid 'FNORGLen' parameter <&01>

Inserts: &01: FNO repeating group length&02: < not used >

&03: < not used >&04: < not used >

Explanation The FNO repeating group length specified in a FNC structured field must be 0x1A.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00830E Invalid 'FNIRGLen' parameter <&01>

Inserts: &01: FNI repeating group length&02: < not used >

&03: < not used >&04: < not used >

Explanation The FNI repeating group length specified in a FNC structured field must be 0x0A or 0x1C.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

42 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS00840E Invalid 'FNPRGLen' parameter <&01>

Inserts: &01: FNP repeating group length&02: < not used >

&03: < not used >&04: < not used >

Explanation The FNP repeating group length specified in a FNC structured field must be 0x16.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00850E Invalid 'FNMRGLen' parameter <&01>

Inserts: &01: FNM repeating group length&02: < not used >

&03: < not used >&04: < not used >

Explanation The FNM repeating group length specified in a FNC structured field must be 0 or 0x08.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

A29247-X16-X-2-7674 43

PRISMAproduction Host CIS Messages

CIS00860E Invalid 'PatAlign' parameter <&01>

Inserts: &01: Pattern data alignment code&02: < not used >

&03: < not used >&04: < not used >

Explanation The Pattern data alignment code specified in a FNC structured field must be 0, 0x02 or 0x03.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00861E The data of Font Mapping Table is missing

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation: The data of Font Mapping Table must be specified in the Structured Field Padding.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

44 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS00862E The Font Mapping Table required but not specified

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation: Processing of the structured field MCF containing a coded font reference (GRID) requires a Font Mapping Table resource which was not specified.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00863E No mapping font name found for the coded font reference (GRID) <&01>.

Inserts: &01: Coded Font Reference&02: < not used >

&03: < not used >&04: < not used >

Explanation: If RESOLVE is specified in parameter FONTMAP.The coded font reference (GRID) specified in the structured field MCF is replaced by a font name, which has be found in the Font Mapping Table.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

A29247-X16-X-2-7674 45

PRISMAproduction Host CIS Messages

CIS00870E Invalid character rotation <&01>

Inserts: &01: Character rotation value&02: < not used >

&03: < not used >&04: < not used >

Explanation The character rotation value specified in a FNO structured field must be 0x0000, 0x2d00, 0x5a00 or 0x8700.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00880E Insufficient font information

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Not all mandatory fields in an MCF or CFI structured fields are available.

Example:An MCF structured field (MFC-1 or MFC-2) must specify either the name of a "Coded Font" or the pair of names for the "Code Page" and the "Font Char-acter Set". A CFI structured field must specify the pair of names for the "Code Page" and the "Font Character Set".

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

46 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00890E Invalid 'SectId' parameter <&01>

Inserts: &01: Coded Font Section id or num-ber&02: Structured field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The resource or field in error is ignored. Processing continues. Subsequent errors are possible.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00900E Invalid 'ResLID' parameter <&01> detected

Inserts: &01: MCF Font Local ID&02: < not used >

&03: < not used >&04: < not used >

Explanation An invalid Font Local ID was found in an MCF structured field. For MCF-2 structured fields, the ID is defined in the Triplet 0x24 (ResLID parameter). For MCF-1 structured fields, the ID is defined in the "CFLid"' parameter.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 47

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00910W Invalid 'CharRot' parameter <&01>

Inserts: &01: Character rotation value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The "Character rotation" parameter in error is ignored and 0° is assumed. Processing continues.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00920W Page-Extent is too large

Inserts: &01: PGD bytes 0 to 11&02: < not used >

&03: < not used >&04: < not used >

Explanation The page extent resulting from the parameters in the Page Descriptor struc-tured field exceeds the page size limits defined by the IS/1 and IS/2 inter-change set (22.75 inches).

CIS Action: Message is issued. Processing continues.

48 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00925E The font <&01,&02> specified in an Object Environment Group is not specified in the Active Environment Group

Inserts: &01: Resource Name (text)&02: Resource Name (bin)

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The resource or field in error is ignored. Processing continues. Subsequent errors are possible.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00930E Invalid 'MMPName' <&01, &02> parameter

Inserts: &01: Medium Map name (text)&02: Medium Map name (bin)

&03: < not used >&04: < not used >

Explanation The specified medium map name that is not available in the Formdef.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 49

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00940E Invalid 'Data_Map_Name' <&01, &02> parameter

Inserts: &01: Data Map name (text)&02: Data Map name (bin)

&03: < not used >&04: < not used >

Explanation The specified data map name that is not available in the Pagedef.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00950E Invalid 'OvlyName' parameter <&01, &02>

Inserts: &01: IPO Overlay name (text)&02: IPO Overlay name (bin)

&03: < not used >&04: < not used >

Explanation The Include Page Overlay structured field specifies an Overlay name that is not defined in the Map Page Overlay structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

50 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00960E Invalid 'ObjName' parameter <&01, &02> in Triplet type <&03>

Inserts: &01: LND Overlay name (text)&02: LND Overlay name (bin)

&03: Triplet type (Tid)&04: LND number

Explanation The Resource Object Include Triplet part of an LND structured field specifies an Overlay name that is not defined in the Map Page Overlay structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00970E Invalid orientation <&01>

Inserts: &01: Orientation value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

A29247-X16-X-2-7674 51

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00980E Invalid mapping option <&01>

Inserts: &01: Mapping option values&02: Drawing order subset version

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS00990E Invalid drawing order subset level <&01> or version <&02>

Inserts: &01: Drawing order subset level&02: Drawing order subset version

&03: < not used >&04: < not used >

Explanation Drawing order subset level must be 1 or 2, and the version must be 0.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

52 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01000E Mandatory Triplet <&01> is missing

Inserts: &01: Triplet type (Tid)&02: < not used >

&03: < not used >&04: < not used >

Explanation The triplet is mandatory but not specified in the structured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01010E The '&01' parameter <&02> is out of range

Inserts: &01: Name of parameter&02: Value of parameter

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 53

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01011E The '&01' parameter is out of range

Inserts: &01: Name of parameter&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01020E Invalid structured field <&01> detected while structured field <&02> was expected

Inserts: &01: Structured field name&02: Structured field name

&03: < not used >&04: < not used >

Explanation A structured field was found in the input data at a location where a different structured field is expected.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

54 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01030E Invalid line data length = 0 if CC Parameter other then NO is specified

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01040E Invalid Line format data <&01> found, while structured field <&02> was expected

Inserts: &01: Invalid data in hex dump format&02: Structured field name

&03: < not used >&04: < not used >

Explanation The Line format data analyzer has detected data which do not correspond to the Line format data specifications.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 55

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01050E Invalid AFP data <&01> found

Inserts: &01: Invalid data in hex dump format&02: < not used >

&03: < not used >&04: < not used >

Explanation The AFP data analyzer has detected data which do not correspond to the AFP specifications.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01060E Invalid 'End_Of_File' detected while structured field <&01> was ex-pected

Inserts: &01: Structured field name&02: Structured field name

&03: < not used >&04: < not used >

Explanation The end of the input data set was detected at a location where a structured field is expected.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

56 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01070E Invalid 'SegFlag' parameter <&01> in 'FlagByte' field of Structured_Field_Introducer

Inserts: &01: SFI FlagByte&02: Structured field name

&03: < not used >&04: < not used >

Explanation The value of the Segflag parameter in the structured field introducer is in-valid or unsupported.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01080E Invalid 'SF_Length' parameter <&01>

Inserts: &01: SFI length parameter&02: Structured field name

&03: < not used >&04: < not used >

Explanation The structured field length parameter part of the structured field introducer (SFI) is invalid.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 57

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01090E Invalid 'RGLength' parameter <&01>

Inserts: &01: Repeating Group Length&02: Structured field name

&03: < not used >&04: < not used >

Explanation The value in the RGLength field of a Repeating Group is invalid or out of bounds.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01100E Invalid data length <&01>

Inserts: &01: Structured Field data length&02: Structured field name

&03: < not used >&04: < not used >

Explanation The length of the data portion of an structured field is invalid.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

58 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01110E Invalid 'Tid' parameter <&01>

Inserts: &01: Triplet type (Tid)&02: Structured field name

&03: < not used >&04: < not used >

Explanation An invalid or unexpected Triplet Type was found while processing a struc-tured field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01120E Invalid 'Tlength' parameter <&01> in Triplet type <&02>

Inserts: &01: Triplet length (Tlength)&02: Triplet type (Tid)

&03: Structured field name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 59

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01130E Invalid 'ExtLength' parameter <&01> in SFI

Inserts: &01: SFI Extension length parameter&02: Structured field name

&03: < not used >&04: < not used >

Explanation The optional "Extension Length" parameter in the Structured Field Introduc-er is invalid.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01140E Invalid 'Padding_Length' parameter <&01>

Inserts: &01: SFI Extension length parameter&02: Structured field name

&03: < not used >&04: < not used >

Explanation The length byte(s) of the optional structured field Padding area is invalid.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

60 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01150E Invalid syntax of Data stream in input file detected.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation the message is related to further message 95000032, 95000033 or 9500034, which is issued while the error was detected by reading process of the input file. The data processing is working continuous until the defec-tive block.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01160E The resulting Units per Unit Base value is outside the allowed range

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Units per unit base conversion was requested, during the conversion pro-cess it was found that the resulting value is outside the range allowed for the associated field.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 61

PRISMAproduction Host CIS Messages

User Response: Check your print job parameters and make sure that the units per unit base conversion is required. Try to reduce the upub parameter value.

CIS01170E TRIGGER parameter not allowed for data containing 'TLE' structured fields

Inserts: &01: Buffer size&02: Structured Field data length

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the TRIGGER param-eter is not specified for files which are not in S/370 Line format data.

CIS01180W Do not save 'TLE' structured field when TRIGGER parameter is speci-fied.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the TRIGGER param-eter is not specified for files which are not in S/370 Line format data.

62 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01190W Do not save 'BNG' and 'ENG' structured fields when TRIGGER param-eter is specified.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The original page group structure is detroyed, the new page group structure will built from the result of the indexing.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the TRIGGER param-eter is not specified for files which are not in S/370 Line format data.

CIS01200E INDEXSTARTBY limit reached and no TRIGGER was found

Inserts: &01: Buffer size&02: Structured Field data length

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the TRIGGER param-eter is correct for the S/370 Line format data print file being processed. Use the INDEXSTARTBY parameter to bypass header pages when present.

A29247-X16-X-2-7674 63

PRISMAproduction Host CIS Messages

CIS01210E The column <&01> in search of index values with the attribute name <&02> is outside of record length

Inserts: &01: CIS column value&02: CIS attribute value

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the column in FIELD parameter, which occured in INDEX parameter with the specified attribute name, is correct for the S/370 Line format data print file being processed. Use the "Error Localization Message

CIS01220E The record <&01> in search of index values with the attribute name <&02> is outside of print file

Inserts: &01: CIS record value&02: CIS attribute value

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the column in FIELD parameter, which occured in INDEX parameter with the specified attribute name, is correct for the S/370 Line format data print file being processed. Use the "Error Localization Message

64 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01230W Insufficient index information

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Not all mandatory fields in a TLE structured fields are available.

CIS Action: The resource or field in error is ignored. Processing continues.

User Response: Check your print job parameters and make sure that the column in FIELD parameter, which occured in INDEX parameter with the specified attribute name, is correct for the S/370 Line format data print file being processed. Use the "Error Localization Message

CIS01240E DEFINEMEDIUMMAP parameter can not modify the medium map <&01, &02> containing N-UP

Inserts: &01: Medium Map name (text)&02: Data Map name (bin)

&03: < not used >&04: < not used >

Explanation Self-explanatory..

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the modification of an existing medium map in the Formdef is required.

A29247-X16-X-2-7674 65

PRISMAproduction Host CIS Messages

CIS01250E DEFINEMEDIUMMAP parameter can not modify the medium map <&01, &02> containing more than one copy group

Inserts: &01: Medium Map name (text)&02: Medium Map name (bin)

&03: < not used >&04: < not used >

Explanation The Medium Map will only contain one copy subgroup, or a pair of copy sub-groups if duplex.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters and make sure that the modification of an existing medium map in the Formdef is required.

CIS01260E Too many text suppressions found during processing DEFINEMEDI-UMMAP parameter

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The test suppressions defined in DEFINEMEDIUMMAP parameter exceed the the maximum number of text suppressions.The maximum number of text suppressions in a Form definition is 127.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

66 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01270E Output buffer size <&01> too short for structured field size <&02>

Inserts: &01: Buffer size&02: Structured Field data length

&03: < not used >&04: < not used >

Explanation The size of the output buffers defined in PSIOUTBL is not large enough to hold the data in the output file.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Increase the buffer size. Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and cor-rectness of the affected data and/or resource(s) against the MO:DCA spec-ifications. Contact your Océ System Engineer in case the data and buffer size are correct.

CIS01280E Input buffer size too short for at least one block

Inserts: &01: Buffer size&02: Structured Field data length

&03: < not used >&04: < not used >

Explanation The size of the input buffers defined in PSIPDSBL and/or PSIRDSBL is not large enough to hold the data in the input file.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Increase the buffer size. Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and cor-rectness of the affected data and/or resource(s) against the MO:DCA spec-ifications. Contact your Océ System Engineer in case the data and buffer size are correct.

A29247-X16-X-2-7674 67

PRISMAproduction Host CIS Messages

CIS01290W Invalid API function '&01' parameter <&02>

Inserts: &01: Name of parameter&02: Value of parameter

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01300W Unsupported inline resource sequence

Inserts: &01: Orientation value&02: < not used >

&03: < not used >&04: < not used >

Explanation The inline resource group of a print file has to appear before any printable data and there can only be one resource group.

CIS Action: The inline resource is ignored. Processing continues. Subsequent errors are possible.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

68 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01301E Unsupported structured field OTX

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The Otext in structured field OTX is not supported by CIS.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01310I No printable output data generated.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Reasons for this message can be:- an empty input file- an input file which consists only of resources- a range parameter, which is outside the data- a remove parameter, which prevents the generation of data

CIS Action: Message is issued. Processing continues.

User Response: Check your input data and/or your print job parameters.

A29247-X16-X-2-7674 69

PRISMAproduction Host CIS Messages

CIS01320I Cannot translate codepoint <&01> from codepage <&02> into codep-age <&03>

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01330E Unsupported Code Page Global Identifier <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01340E Invalid Code Page Global Identifier <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

70 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation The valid range of Code page Global Identifier is 0x0001- 0xFFFE.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01350E Unsupported Coded Character Set Identifier <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01360I &01 '&02': Cannot create the complete sprintf_string

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 71

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01370I &01 '&02': Output contains insufficient data

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01380E Mail Piece number <&01> does not start/end at a sheet boundary

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

72 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01390E Insert BCOCA/PTOCA: No 1st partition defined for this FORMDEF.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01400E Insert BCOCA/PTOCA: No page for 1st partition received.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01410E Insert '&01': &02 position outside logical page. Minimum size must be &03.

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 73

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01420I Insert '&01' failed:

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01430I Level with entity '&01', location '&02', entity selector '&03' not included in AFP data stream.

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

74 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS01450W Plugin &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01460W Data Enrichment &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01470E <&01,&02> could not be found in the resource library

Inserts: &01: Resource Name (text)&02: Resource Name (bin)

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 75

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01480E Maximum number of resources exceeded.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Maxiumum number of resources is USHRT_MAX (= 65535, 0xffff)

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Use the "Error Localization Messages" following this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS01490E The file <&01> for resource does not exist.

Inserts: &01: File Name&02: < not used >

&03: < not used >&04: < not used >

Explanation The file name is specified in parameter file i.e in the parameter DEFINE-CONTAINER.

76 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: Check your print job parameters.

CIS01500E Layout-Sorting not allowed with more than one pagegroup in a docu-ment

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation This release of CIS only allows layout-sorting of AFP data with a single Be-ginDocument and a single BeginPageGroup structured field containing the pages (called: flat data hierarchy).

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01510E There must be 2 pages a sheet at least to apply SORT SCHEME_1

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

A29247-X16-X-2-7674 77

PRISMAproduction Host CIS Messages

CIS01520E Number of pages per sheet not constant

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01530E There must be 2 pages a sheet at least to apply SORT SCHEME_2

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01540E There must be 1 page a sheet at least to apply SORT SCHEME_3

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

78 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01550E There must be 8 page a sheet at least to apply SORT 4UP_BOOKLET

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01560E There must be 4 page a sheet at least to apply SORT 2UP_BOOKLET or MP_2UP_BOOKLET

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

A29247-X16-X-2-7674 79

PRISMAproduction Host CIS Messages

CIS01570E Plugin <&01>: Plugin function maxNumberOfPagesInSheetOK(&02) failed.

Inserts: &01: Plugin Name&02: CIS value

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01580I Sort Attribute &01in mailpiece #&02 of document #&03 missing.

Inserts: &01: general character string&02: general integer value

&03: general integer value&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01590E Have tried to display an unknown message <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

80 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01600E Message should have an insert, but hasn't

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

CIS01610E Have run out of message inserts in the insert list

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

A29247-X16-X-2-7674 81

PRISMAproduction Host CIS Messages

CIS01620E Call to system command GETMAIN has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01630E Invalid insert length &01

Inserts: &01: <variable data>&02: <variable data>

&03: CIS trigger name&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01640E Call to system command GETMAIN has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

82 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01650E Call to system command ENQ has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01660E Call to system command DEQ has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 83

PRISMAproduction Host CIS Messages

CIS01670E Call to system command WAIT has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01680E System call 'IDENTIFY' has failed with RC <0x&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: Contact your Océ Systems Engineer.

CIS01690E System call 'LOCKLIFO' has failed with RC <0x&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

84 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing continues.

User Response: Contact your Océ Systems Engineer.

CIS01700E Cannot find thread information for the given TCB

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01710E Thread &01 has ended abnormally

Inserts: &01: Thread name (text)&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 85

PRISMAproduction Host CIS Messages

CIS01720E Open on DDname &1 has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Check your print job parameters.

CIS01730E Open on the trace file <&01> not possible

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01740E Open on the trace file <&01> not possible

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

86 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01750E Open on the Primary Data Stream file has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01760E Close on the Primary Data Stream file has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 87

PRISMAproduction Host CIS Messages

CIS01770E Call to getpos() failed with error code &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01780E Call to setpos() failed with error code &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01790E Call to fread() failed with error code &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

88 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01800E Call to afread() failed with error code &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01810E Unable to allocate more global memory

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 89

PRISMAproduction Host CIS Messages

CIS01820E Invalid ID received from PS

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01830E Call to osddinfo() failed with error code number &1

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01840E Couldn't open the resource file &01

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

90 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01850E Couldn't locate the key in file &01

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01860E Couldn't insert data into file &01

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 91

PRISMAproduction Host CIS Messages

CIS01870E Couldn't replace record in file &01

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01880E Couldn't open parameter input file

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Check your print job parameters.

CIS01890E Couldn't get dd information for &01

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

92 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: Check your print job parameters.

CIS01891W Couldn't get dd information for trace file &01.

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation DD statement for trace file is not available, trace facility will be switched off, processing continues.

CIS Action: None.

User Response: Check your print job parameters.

CIS01900I Unable to determine library name for &01 resource &02

Inserts: &01: RDS type&02: Resource Name (text)

&03: < not used >&04: < not used >

Explanation Have looked for a library containing the given resource, but without success.

CIS Action: The resource or field in error is ignored. Processing continues.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

A29247-X16-X-2-7674 93

PRISMAproduction Host CIS Messages

CIS01910E Open on the ESD Data Stream file &01 has failed

Inserts: &01: DD name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS01920E Couldn't open parameter codepage file

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Check your print job parameters.

CIS01930E Invalid character found in file <&01> at position <&02>.

Inserts: &01: general file name&02: general integer value

&03: < not used >&04: < not used >

Explanation The given file contains a charcter not defined in the current active codepage.

94 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: Check your print job parameters.

CIS01940I Library dataset &01 does not exist

Inserts: &01: RDS type&02: Resource Name (text)

&03: < not used >&04: < not used >

Explanation A passed library does not exist

CIS Action: The resource or field in error is ignored. Processing continues.

User Response: None.

CIS01950I Error allocating Dataset &01

Inserts: &01: RDS type&02: < not used >

&03: < not used >&04: < not used >

Explanation An error occured trying to dynamically allocate the given dataset.

CIS Action: The resource or field in error is ignored. Processing continues.

User Response: None.

A29247-X16-X-2-7674 95

PRISMAproduction Host CIS Messages

CIS01960W Invalid AFP-SF length

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation While parsing input file an invalid AFP-SF length was encounterd.

CIS Action: None.

User Response: None.

CIS01970W Unexpected end of file

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation While parsing input file an unexpected end of file was encounterd.

CIS Action: None.

User Response: None.

CIS01980W AFP-SF syntax error

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

96 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation While parsing input file an AFP-SF syntax error has encountered.

CIS Action: None.

User Response: None.

CIS01990W Empty line detected in input line data

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation While parsing input file an empty line was detected in AFP input stream.

CIS Action: None.

User Response: None.

CIS02000E Plugin <&01>: CIS API version number <&02> is not supported.

Inserts: &01: Plugin Name&02: CIS Plugin API Version Number

&03: < not used >&04: < not used >

Explanation The loaded Plugin expects another CIS API version number

CIS Action: None.

User Response: None.

A29247-X16-X-2-7674 97

PRISMAproduction Host CIS Messages

CIS02010E Plugin <&01>: CIS API version number <&02> and number of CIS-pro-vided API functions <&03> mismatch

Inserts: &01: Plugin Name&02: CIS Plugin API Version Number

&03: number of CIS-provided API functions&04: < not used >

Explanation The loaded Plugin reports a mismatch between CIS API version number and the number CIS provided API functions

CIS Action: None.

User Response: None.

CIS02020E Plugin <&01>: module not found.

Inserts: &01: Plugin Name&02: < not used >

&03: < not used >&04: < not used >

Explanation The Plugin module was not found.

CIS Action: None.

User Response: None.

CIS02030E Plugin <&01>: entry function <&02> not found.

Inserts: &01: Plugin Name&02: Plugin Entry function

&03: < not used >&04: < not used >

98 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Plugin entry function not found.

CIS Action: None.

User Response: None.

CIS02040E Plugin <&01>: Interface version number <&02> is not supported.

Inserts: &01: Plugin Name&02: CIS Plugin API Version Number

&03: < not used >&04: < not used >

Explanation Interface version number is not supported.

CIS Action: None.

User Response: None.

CIS02050E Plugin <&01>: Interface version number <&02> and number of Plugin-provided API functions <&03> mismatch

Inserts: &01: Plugin Name&02: CIS Plugin API Version Number

&03: number of CIS-provided API functions&04: < not used >

Explanation Mismatch between Plugin API version number and the number of Plugin provided API functions

CIS Action: None.

A29247-X16-X-2-7674 99

PRISMAproduction Host CIS Messages

User Response: None.

CIS02060E Double sent &01, possibly error in sort plugin.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02070I Unable to free Dataset <&01>

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02080E Wrong DSN syntax &01

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

100 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02090E Dynamic Allocation of &01 failed. RetCode &02, reason &03

Inserts: &01: general file name&02: general hex value

&03: general hex value&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02100E Dynamic Allocation of &01 cannot determine the DSORG

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

A29247-X16-X-2-7674 101

PRISMAproduction Host CIS Messages

CIS02110E Dynamic Allocation of &01: Wrong DSORG. Neither PO nor PS

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02120E Dynamic Allocation of &01: DSORG is PS

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02130E Dynamic Allocation of &01: DSORG is PO

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

102 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: None.

User Response: None.

CIS02140E Dynamic Allocation of &01: Couldn't get a DCB

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02150E OPEN for &01 failed. RetCode: &02

Inserts: &01: general file name&02: general hex value

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

A29247-X16-X-2-7674 103

PRISMAproduction Host CIS Messages

CIS02160E Cannot FIND member for &01

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02170E Input Record Plugin: Unable to load module <&01>.

Inserts: &01: Plugin Name&02: < not used >

&03: < not used >&04: < not used >

Explanation The input record plug-in module could not get loaded or the library entry function has not been found.

CIS Action: None.

User Response: None.

CIS02180E Input Record Plugin: Remove request after recall request.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

104 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation The input record plug-in module wants to remove the same record it just has inserted. That behavior makes no logical sense.

CIS Action: None.

User Response: None.

CIS02181E Input Record Plugin: Invalid request (&01)

Inserts: &01: general integer value&02: < not used >

&03: < not used >&04: < not used >

Explanation The input record plug-in module returns an unallowed request value.Valid values are:0: REQ_PROCESS1: REQ_REMOVE2: REQ_RECALL

CIS Action: None.

User Response: None.

CIS02182E Unable to determine dataset type of &01.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation DD is neither of type SYSOUT nor "OTHERWISE" (Authorized Assembler Service Guide - DYNALLOC(DINRTTYP)).

CIS Action: None.

A29247-X16-X-2-7674 105

PRISMAproduction Host CIS Messages

User Response: None.

CIS02183E No DCB LRECL parameter defined for document output dataset (&01).

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation DD statements of type SYSOUT mandatory need a DCB LRECL definition.

CIS Action: None.

User Response: None.

CIS02184E Dynamic allocation of <&01> failed.

Inserts: &01: general character string&02: < not used >

&03: < not used >&04: < not used >

Explanation None.

CIS Action: None.

User Response: None.

CIS02190E Dynamic Inquiry of &01 failed. RetCode &02, reason &03

Inserts: &01: general file name&02: general hex value

&03: general hex value&04: < not used >

106 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02200E Wrong dataset organisation of <&01>.

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02201E AFP record length <&01> exceeds output file's (&02) record length <&03>

Inserts: &01: general integer value&02: general file name

&03: general integer value&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

A29247-X16-X-2-7674 107

PRISMAproduction Host CIS Messages

CIS02202E Wrong dataset type specification of <&01>. Dataset must be of type &02.

Inserts: &01: general file name&02: general character string

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02203E Error on closing of <&01>. Possibly no or not enough directory blocks allocated.

Inserts: &01: general file name&02: < not used >

&03: < not used >&04: < not used >

Explanation Add directory blocks to SPACE parameter of JCL DD statement in case of PO datasets.

CIS Action: None.

User Response: None.

CIS02204E Too many open pipes per process.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

108 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02205E select() failed with errno <&01>.

Inserts: &01: general integer value&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanating message

CIS Action: None.

User Response: None.

CIS02210E No parameter found for keyword <&01>

Inserts: &01: CIS keyword name&02: < not used >

&03: < not used >&04: < not used >

Explanation No parameters were found for a keyword that requires one or more manda-tory parameters.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 109

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02220E Invalid keyword <&01>

Inserts: &01: CIS keyword name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02230E Invalid parameter = &01, for keyword &02

Inserts: &01: CIS parameter name&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

110 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02240E In line <&01> no open bracket found

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02250E Invalid length = <&01> (must be < 9) for parameter <&02>, keyword = <&03>

Inserts: &01: <variable data>&02: CIS parameter name

&03: CIS keyword name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 111

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02260E Invalid parameter <&01> ( only digit values allowed ) for keyword <&02>

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02270E Invalid amount of parameter <&01> for keyword <&02>

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

112 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02280E Invalid odd length for hex literal X'<&01>', field- or trigger-name = <&02>

Inserts: &01: <variable data>&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02290E Invalid hex value = <&01> (only 0 - 9 and A - F allowed) in hex literal X'<&02>', field- or trigger-name = <&03>

Inserts: &01: <variable data>&02: <variable data>

&03: CIS field name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 113

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02300E For index <&01> given triggername <&02> not declared

Inserts: &01: CIS index name&02: CIS trigger name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02310E For index <&01> given fieldname <&02> not declared

Inserts: &01: CIS index name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

114 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02320E Invalid combination of parameters <&01>, keyword = <&02>

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02330E Multiple definition of keyword <&01>

Inserts: &01: CIS keyword name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 115

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02340E Groupname <&01> not found in indexlist

Inserts: &01: CIS index name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02350E Sort attribute <&01> not found in index declarations

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

116 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02360E Invalid first record value must be '*' in trigger <&01>

Inserts: &01: CIS trigger name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02370E Invalid first record value must not be '*' in trigger <&01>

Inserts: &01: CIS trigger name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 117

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02380E In groupname a multiple definition of indexes for trigger <&01> exists

Inserts: &01: CIS trigger name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02390E For index <&01> the length <&02> for all fields exceeds 250

Inserts: &01: CIS index name&02: CIS length value

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

118 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02400E Resource-name-length = &01 is invalid (allowed length <= &02), re-source-name = &03..., keyword = &04

Inserts: &01: <variable data>&02: <variable data>

&03: CIS parameter name&04: CIS keyword name

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02410E No message found for returncode = &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation No parameters were found for a keyword that requires one or more manda-tory parameters.

A29247-X16-X-2-7674 119

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02420E Amount of insert-placeholders = &01 is larger than amount of inserts = &02, keyword = &03

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02430E Insert-type = %&01 is not supported, keyword = &02

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

120 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02440E Invalid value = &01 for parameter &02, keyword = &03, name = &04

Inserts: &01: <variable data>&02: CIS parameter name

&03: CIS keyword name&04: <variable data>

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02450E Name-length = &01 is invalid (allowed length < &02 ) Name = &03..., keyword = &04

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: CIS keyword name

Explanation Self explanatory.

A29247-X16-X-2-7674 121

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02460E _Keyword = &01 is invalid, keyword = &02

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02470E Invalid segment counter, must be > 0 and < &01, keyword = &02

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

122 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02480E In parameter &01 a none digit value was found, keyword = &02

Inserts: &01: <variable data>&02: CIS keyword name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02490E Multiple definition of Bcoca <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 123

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02500E Multiple definition of Ptoca <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02510E Invalid mxm-value = &01 in chars-parameter

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

124 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02520E Invalid size-value = &01 in selsize-parameter

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02530E No range given in selrange-parameter

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 125

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02540E From value = &01 is larger than to value = &02, keyword = &03

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02550E Value = &01 is smaller than min value = &02, keyword = &03

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: < not used >

Explanation Self explanatory.

126 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02560E Value = &01 is larger than max value = &02, keyword = &03

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02570E If segmentation is on, no indexing can be done

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The INDEXOBJ-parameter was set to another value than NONE, while the SEGMENT-parameter is on.

A29247-X16-X-2-7674 127

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02580E Too many parameters in Selrangerandom

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02590E In selrange include value <&01> overlaps with exclude value <&02>

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

128 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02600E Levels of selrange and selrangerandom are different

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02610E In selindexrange include value <&01> overlaps with exclude value <&02>

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 129

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02620E In insertbcoca bcocaname = &01, the field = <&02> isn't a literal field

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02630E The bcoca with bcocaname = &01 used in insert, is not defined

Inserts: &01: CIS parameter name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

130 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02640E In insertbcoca bcocaname = &01, the field = <&02> isn't defined

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02650E In insertptoca ptocaname = &01, the field = <&02> isn't a literal field

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 131

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02660E The ptoca with ptocaname = &01 used in insert, is not defined

Inserts: &01: CIS parameter name&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02670E In insertptoca ptocaname = &01, the field = <&02> isn't defined

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

132 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02680E In insertindex indexname = &01, the field = <&02> isn't a literal field

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02690E In insertindex indexname = &01, the field = <&02> isn't defined

Inserts: &01: CIS parameter name&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

A29247-X16-X-2-7674 133

PRISMAproduction Host CIS Messages

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02700E Medium Map '&01' not found.

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation The Medium Map Name was not found!

CIS Action: None.

User Response: None.

CIS02710E None parsed information = <&01>

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

134 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02720E Parameterlength = <&01> exceeds allowed size = <&02>

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02730W Warning at the end of CIS-Parameterfile an open comment exists

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: None.

A29247-X16-X-2-7674 135

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02740E If a scheme-sort parameter is defined, no trigger or indexobj or group-name must be given

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: None.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02750E The filename = <&01> exists in more than once ExtractIndex parameter

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

136 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02760E The value = <&01> has to be written in quotes (e.g. 'value')

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02770E In insert name = <&01>, the field = <&02> doesn't match format speci-fier = <%&03>

Inserts: &01: <variable data>&02: CIS field name

&03: <variable data>&04: < not used >

Explanation e. g. the user wants to insert a _keyword field, which is always a decimal number, with the insert type %s.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 137

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02780E Invalid amount of parameters for <&01>, <&02> are missing

Inserts: &01: CIS parameter name&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02790E The sprintf_string = <&01> is incomplete

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

138 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02800E For ExtractIndex to file <&01> given fieldname <&02> not declared

Inserts: &01: <variable data>&02: CIS field name

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02810E If INPUTFORMAT = MODCA no CC- or TRCTYPE other then NO can be specified.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

A29247-X16-X-2-7674 139

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02820W &01 parameter should be used together with RESTYPE ( FDEF ).

Inserts: &01: CIS parameter name&02: < not used >

&03: < not used >&04: < not used >

Explanation If the parameter &01 is given and RESTYPE ( FDEF ) is not given, the nec-essary modifications of the FORMDEF will not be done.

CIS Action: None.

User Response: None.

CIS02830E If OUTPUTSEG = BYTE creation of ANALYST-Information not possible.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation The ANALYST-Paramter has to be set to NONE or the segmentation level must be other than BYTE

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

140 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02840E &01 parameter must be used together with RESTYPE ( ALL ).

Inserts: &01: CIS parameter name&02: < not used >

&03: < not used >&04: < not used >

Explanation If the parameter &01 is given and RESTYPE ( ALL ) is not given processing stops.

CIS Action: None.

User Response: Insert RESTYPE (ALL) in the parameterfile, or change the existing RESTYPE definition to RESTYPE (ALL).

CIS02850W &01 parameter must be used together with RESTYPE ( OBJCON ).

Inserts: &01: CIS parameter name&02: < not used >

&03: < not used >&04: < not used >

Explanation If the parameter &01 is given and RESTYPE ( OBJCON ) is not given pro-cessing stops.

CIS Action: None.

User Response: Insert RESTYPE (OBJCON) in the parameterfile, or change the existing RESTYPE definition to RESTYPE (ALL)

A29247-X16-X-2-7674 141

PRISMAproduction Host CIS Messages

CIS02860E Conversion of value = <&01> failed

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02870E An unexpected right parenthesis detected, processing stopped.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: None.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

142 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS02880E Conversion of value = <&01> failed, because INPUTCP = UNKNOWN

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02890E The &01 with name = &02 used in insert, is not defined.

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

A29247-X16-X-2-7674 143

PRISMAproduction Host CIS Messages

CIS02900E Invalid value = <&01> for parameter = <&02>.

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02910E The level = <&01> used in = <&02> with name = <&03> is not defined

Inserts: &01: <variable data>&02: CIS parameter name

&03: <variable data>&04: < not used >

Explanation The level the user uses in an insert or extract parameter is not with de-finelevel defined.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

144 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS02920E The level = <&01> used in = <&02> with name = <&03> is not allowed

Inserts: &01: <variable data>&02: CIS parameter name

&03: <variable data>&04: < not used >

Explanation The level the user uses in an insert or extract parameter is not allowed.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02930E &01 with name = <&02> is already defined.

Inserts: &01: <variable data>&02: CIS parameter name

&03: < not used >&04: < not used >

Explanation The level the user uses in an insert or extract parameter is not allowed.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

A29247-X16-X-2-7674 145

PRISMAproduction Host CIS Messages

CIS02940E The color = <&01> used in = <&02> with name = <&03> is not defined.

Inserts: &01: <variable data>&02: CIS keyword name

&03: <variable data>&04: < not used >

Explanation The color the user uses in an define parameter is not with definecolor de-fined.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02950E The fillColor = <&01> used in = <&02> with name = <&03> is not de-fined.

Inserts: &01: <variable data>&02: CIS keyword name

&03: <variable data>&04: < not used >

Explanation The fillColor the user uses in an define parameter is not with definecolor de-fined.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

146 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS02960E The fillColor = <&01> used in = <&02> with name = <&03> is not de-fined.

Inserts: &01: <variable data>&02: CIS keyword name

&03: <variable data>&04: < not used >

Explanation The fillColor the user uses in an define parameter is not with definecolor de-fined.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02970E Parameter = <&01> is not defined.

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation The parameter must be given.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

A29247-X16-X-2-7674 147

PRISMAproduction Host CIS Messages

CIS02980E The name = <&01> used in = <&02> is already used in a <&03> param-eter.

Inserts: &01: <variable data>&02: CIS parameter name

&03: <variable data>&04: < not used >

Explanation The names for the DEFINE-Parameters have to be unique.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS02990E Name-length = &01 is invalid (allowed length <= &02 ) Name = &03..., keyword = &04

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: CIS keyword name

Explanation Self explanatory.

CIS Action: The processing of the print data set associated with the resource(s) or field(s) in error is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

148 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS03000E Parameter = <&01> is not defined &02.

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation The parameter must be given, because the parameter in &02 has a value other than default.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS03010E The &01 <&02> used in <&03> with name <&04> is not defined.

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: <variable data>

Explanation &01 is the parameter, &02 is the parameter-value, &03 the keyword where the parameter was used, &04 the name used in the keyword

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

A29247-X16-X-2-7674 149

PRISMAproduction Host CIS Messages

CIS03020E The &01 with name <&02> used in <&03> is not defined.

Inserts: &01: <variable data>&02: <variable data>

&03: CIS keyword name&04: < not used >

Explanation The parameter must be given, because it is used in &03.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS03030E The user exit program name is not defined.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation In a _sprintfString the user has written 'USEREXIT', but he has no field giv-en, where the user exit program name is specified.

CIS Action: None.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

150 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS03040E The field <&01> can't be used in <&02> with name <&03> because it's &04.

Inserts: &01: CIS field name&02: CIS keyword name

&03: CIS parameter name&04: <variable data>

Explanation In an insertparameter a field which is defined hex or record column length is used.

CIS Action: None.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS03050I Cannot translate character <&01> from codepage <&02> into codep-age <&03>, &04

Inserts: &01: <variable data>&02: <variable data>

&03: <variable data>&04: <variable data>

Explanation Self explanatory.

CIS Action: Message is issued. Processing continues.

User Response: None.

A29247-X16-X-2-7674 151

PRISMAproduction Host CIS Messages

CIS03060W &01 parameter should be used together with RESTYPE ( &02 ).

Inserts: &01: CIS parameter name&02: <variable data>

&03: < not used >&04: < not used >

Explanation A parameter was detected which needs a certain RESTYPE to be given.

CIS Action: Message is issued. Processing continues.

CIS03061E If &01 is enabled < &02 > is not allowed.

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation The user declared &01 in his parameter-file, so &02 is not allowed.

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS03062E In DEFINEMEDIUMMAP with name &01,if MEDIAATTRIBUTES are specified, also a MEDIATYPE or MEDIANAME must be specified.

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation self explanatory

152 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: The parameter syntax allowed for CIS is documented in the CIS User's Guide. Use the documentation that matches the version of CIS being used and verify the correctness of the affected parameter(s) and/or keyword(s). Hint: Check your parameter file for correct comment signs. Contact your Océ System Engineer in case the parameters are correct.

CIS03070E Attempt to make new Tracer has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03080E Attempt to make new Event_Manager has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 153

PRISMAproduction Host CIS Messages

CIS03090E Attempt to make new Lock_Manager has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03100E Attempt to make new Thread_Manager has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03110E Attempt to make new RDS_Manager has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

154 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03120E Attempt to make new ESD_Manager has failed

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03130I Processing completed. No errors found.

Inserts: &01: DD name&02: <variable data>

&03: CIS trigger name&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 155

PRISMAproduction Host CIS Messages

CIS03140E Error occurred while processing input parameters

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03150W Processing completed. One or more warning messages were issued.

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS03160E Processing terminated. One or more errors have occurred.

Inserts: &01: DD name&02: <variable data>

&03: CIS trigger name&04: < not used >

156 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS03170E Processing terminated. One or more severe errors have occurred.

Inserts: &01: DD name&02: <variable data>

&03: CIS trigger name&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: Use the "Error Localization Messages" preceding this message to determine the exact error location. Verify the origin and correctness of the affected data and/or resource(s) against the MO:DCA specifications. Contact your Océ System Engineer in case the data is correct.

CIS03180E Cannot open SYSPRINT for writing

Inserts: &01: < not used >&02: < not used >

&03: < not used >&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

A29247-X16-X-2-7674 157

PRISMAproduction Host CIS Messages

User Response: None.

CIS03190E Program failure in &01

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation An internal error has caused CIS processing to terminate abnormally.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03191E Signal &01 (&02) receive on thread <&03>

Inserts: &01: general character string&02: general character string

&03: general character string&04: < not used >

Explanation Self explanatory.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03200E Structured Field &01: &02

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

158 A29247-X16-X-2-7674

PRISMAproduction Host CIS Messages

Explanation An internal structured field data error has occurred.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03201E Repeating Group &01: &02

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation An internal repeating group data error has occurred.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03202E Triplet X'&01': &02

Inserts: &01: <variable data>&02: < not used >

&03: < not used >&04: < not used >

Explanation An internal triplet data error has occurred.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

A29247-X16-X-2-7674 159

PRISMAproduction Host CIS Messages

CIS03209E Control Sequence &01: &02

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation An internal control sequence data error has occurred.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

CIS03210E Drawing Order &01: &02

Inserts: &01: <variable data>&02: <variable data>

&03: < not used >&04: < not used >

Explanation An internal drawing order data error has occurred.

CIS Action: Message is issued. Processing is stopped.

User Response: None.

160 A29247-X16-X-2-7674