how to order guide hvs3000 high volume air samplers

17
How to order guide HVS3000 High Volume Air Samplers Version: 2.0 www.ecotech.com

Upload: khangminh22

Post on 24-Apr-2023

1 views

Category:

Documents


0 download

TRANSCRIPT

How to order guide

HVS3000 High Volume Air Samplers

Version: 2.0

www.ecotech.com

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 2

This page is intentionally blank

Page 3

Table of Contents

Table of Contents ........................................................................................................................................................... 3

1.1 Introduction ....................................................................................................................................................... 3

1.2 How to order a HiVol 3000 Standard Version .................................................................................................... 5 1.2.1 Download Software ............................................................................................................................... 7 1.2.2 Consumables/Spares ............................................................................................................................. 7

1.3 How to order a HiVol 3000 PUF.......................................................................................................................... 8 1.3.1 Download Software ............................................................................................................................... 9 1.3.2 Consumables/Spares ........................................................................................................................... 10

1.4 How to order a HiVol 3000 XAD ....................................................................................................................... 10 1.4.1 Download Software ............................................................................................................................. 12 1.4.2 Consumables/Spares ........................................................................................................................... 12

1.5 How to order a MegaVol 3000 ......................................................................................................................... 13 1.5.1 Download Software ............................................................................................................................. 14 1.5.2 Consumables/Spares ........................................................................................................................... 14

1.1 Introduction

The HiVol 3000 sampler has four different instruments that collect slightly different compositions of particulate and VOC matter.

The instrument must be chosen first by application (what type of sampling/particulates are being monitored for) then what size particulates are being sampled and finally any additional accessories can be added.

The four types of instruments are explained below

HiVol 3000 Standard

Measures general particulate matter

45-96m3/h

200mm x 250mm Pallflex Filters

U.S. EPA Manual Reference Method: RFPS-0706-162 for PM10

HiVol 3000 PUF

Measures particulate matter with specialization in organic compounds (pesticides etc)

Flow rate: 10-20m3/h

Quartz Filters PUF (Poly-urethane foam)

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 4

HiVol 3000 XAD

Measures particulate matter with a wider variety of organic compounds compared to PUF sampler

Flow rate: 10-15m3/h

Glass cartridge with XAD beads (Hydrophobic Polyaromatic Resin) surrounded by PUF

MegaVol 3000

Measures low concentrations of heavy metals and radioactive particulates

Flow rate: 120-150m3/h

Standard 200mm x 250mm Pallflex Filters with additional Iodine trap available

Page 5

1.2 How to order a HiVol 3000 Standard Version

Requirement Part Number Description

The customer requires a Standard HiVol sampler!

The following unit must be ordered for standard particulate sampling

HiVol 3000 sampler (240V 50/60 Hz)

ECO-HVS3000 Power: 240V 50/60 HZ – non CE compliant

HiVol 3000 sampler (115V 60 Hz)

E040001 Power: 115V 60 Hz – non CE compliant

HiVol 3000 sampler (240V 50/60 Hz) – CE compliant

E040020 Power: 240V 50/60 Hz – CE Compliant

What size particulate monitoring is required?

Choose the size selective inlet (SSI) necessary for the application

TSP (Total suspended particulates)

ECO-HVS3000-01 Inlet head for TSP sampling

PM10 ECO-HVS3000-02 Inlet head for PM10 sampling

PM2.5 ECO-HVS3000-03 Inlet head for PM2.5 sampling

What optional accessories does the customer require?

Add from the list below any accessories the customer requires

Wind speed/direction sensor WITH

attachments

ECO-HVS3000-40 Model 034B wind speed direction sensor (Includes Sensor, mounting support and sensor cable)

Wind speed/direction sensor WITHOUT attachments

ZMM-034B Model 034B wind speed direction sensor

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 6

Wind sensor cable CAB-HVS300007 3m Cable for 034B Sensor

Wind sensor mounting arm HAR-HV3002 HiVol Mounting Arm for 034B Sensor (onto chassis)

Muffler ECO-HVS3000-51 Muffler reduces the sound of the HiVol

Calibration orifice plate ECO-HVS3000-21 Allows calibration of HiVol when used with a manometer

300 mm U Tube Manometer

ATM-1000 U tube manometer uses water to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Manometer

ECO-HVS3000-24 Digital manometer to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Barometer AIR72498101

ECO-HVS3000-25 Digital Barometer used to measure ambient pressure(used in calibrations)

0-50 deg. C Max/Min Mercury Thermometer

ATM-1003 Mercury thermometer used to measure ambient temperature (used in calibrations)

Digital Thermometer (not NATA certified)

ECO-HVS3000-27 Digital thermometer used to measure ambient temperature (used in calibrations)

Transport case for field calibration equipment

ECO-HVS3000-22 Used to easily carry calibration orifice plate and other calibration equipment (U tube manometer will not fit)

Page 7

1.2.1 Download Software

How do I download data off the HVS3000?

Airodis Demo Ecotech’s Airodis Demo software is free and can be used for downloading data. It is provided on the green “resources” USB memory stick provided with the sampler.

Airodis Full Version Refer to the Airodis How To Order Guide

Airodis can be used to automatically or manually download data from the sampler. More information is available at www.airodis.com

1.2.2 Consumables/Spares

Part Number Description

ECO-200010 100 x PTFE 200mm x 250mm Pallflex Filters

ECO-HVS3000-52 Spare Filter Cassette

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 8

1.3 How to order a HiVol 3000 PUF

Requirement Part Number Description

The customer requires a HiVol PUF sampler!

The following unit must be ordered for PUF sampling

HiVol 3000 PUF sampler ECO-HVS3000PUF HiVol 3000 PUF sampler

The customer requires a TSP inlet head!

The size selective inlet (SSI) below must be selected

TSP (Total suspended particulates)

ECO-HVS3000-01 Inlet head for TSP sampling

The customer requires a PUF Sampling Adaptor!

The PUF sampling adaptor is used necessary for capturing PAH’s

PUF Sampling Adaptor ECO-200030 PUF Organic Toxic Sampling Adaptor including one glass container, PUF plug and Teflon caps.

What optional accessories does the customer require?

Add from the list below any accessories the customer requires

Wind speed/direction sensor WITH

attachments

ECO-HVS3000-40 Model 034B wind speed direction sensor (Includes Sensor, mounting support and sensor cable)

Wind speed/direction sensor WITHOUT attachments

ZMM-034B Model 034B wind speed direction sensor

Wind sensor cable CAB-HVS300007 3m Cable for 034B Sensor

Wind sensor mounting arm HAR-HV3002 HiVol Mounting Arm for 034B Sensor (onto chassis)

Page 9

Muffler ECO-HVS3000-51 Muffler reduces the sound of the HiVol

Calibration orifice plate ECO-HVS3000-21PU Allows calibration of HiVol PUF when used with a manometer

300 mm U Tube Manometer

ATM-1000 U tube manometer uses water to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Manometer

ECO-HVS3000-24 Digital manometer to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Barometer AIR72498101

ECO-HVS3000-25 Digital Barometer used to measure ambient pressure(used in calibrations)

0-50 deg. C Max/Min Mercury Thermometer

ATM-1003 Mercury thermometer used to measure ambient temperature (used in calibrations)

Digital Thermometer (not NATA certified)

ECO-HVS3000-27 Digital thermometer used to measure ambient temperature (used in calibrations)

Transport case for field calibration equipment

ECO-HVS3000-22 Used to easily carry calibration orifice plate and other calibration equipment (U tube manometer will not fit)

1.3.1 Download Software

How do I download data off the HVS3000?

Airodis Demo Ecotech’s Airodis Demo software is free and can be used for downloading data. It is provided on the green “resources” USB memory stick provided with the sampler.

Airodis Full Version Refer to the Airodis How To Order Guide

Airodis can be used to automatically or manually download data from the sampler. More information is available at www.airodis.com

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 10

1.3.2 Consumables/Spares

Part Number Description

ECO-200030 Polyurethane Foam (PUF) Organic Toxic Sampling Adaptor

ECO-HVS3000-52 Spare Filter Cassette

ECO-200030-1 Glass Container with teflon caps with PUF material & SS Screens

ECO-200030-4 Quartz Filters for PUF (Box of 25)

1.4 How to order a HiVol 3000 XAD

Requirement Part Number Description

The customer requires a Standard HiVol sampler!

The following unit must be ordered for standard particulate sampling

HiVol 3000 XAD sampler ECO-HVS3000XAD HiVol 3000 XAD sampler

The customer requires a TSP inlet head!

The size selective inlet (SSI) below must be selected

TSP (Total suspended particulates)

ECO-HVS3000-01 Inlet head for TSP sampling

What optional accessories does the customer require?

Add from the list below any accessories the customer requires

Wind speed/direction sensor WITH

attachments

ECO-HVS3000-40 Model 034B wind speed direction sensor (Includes Sensor, mounting support and sensor cable)

Page 11

Wind speed/direction sensor WITHOUT attachments

ZMM-034B Model 034B wind speed direction sensor

Wind sensor cable CAB-HVS300007 3m Cable for 034B Sensor

Wind sensor mounting arm HAR-HV3002 HiVol Mounting Arm for 034B Sensor (onto chassis)

Muffler ECO-HVS3000-51 Muffler reduces the sound of the HiVol

Calibration orifice plate ECO-HVS3000-21XA Allows calibration of HiVol XAD when used with a manometer

300 mm U Tube Manometer

ATM-1000 U tube manometer uses water to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Manometer

ECO-HVS3000-24 Digital manometer to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Barometer AIR72498101

ECO-HVS3000-25 Digital Barometer used to measure ambient pressure(used in calibrations)

0-50 deg. C Max/Min Mercury Thermometer

ATM-1003 Mercury thermometer used to measure ambient temperature (used in calibrations)

Digital Thermometer (not NATA certified)

ECO-HVS3000-27 Digital thermometer used to measure ambient temperature (used in calibrations)

Transport case for field calibration equipment

ECO-HVS3000-22 Used to easily carry calibration orifice plate and other calibration equipment (U tube manometer will not fit)

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 12

1.4.1 Download Software

How do I download data off the HVS3000?

Airodis Demo Ecotech’s Airodis Demo software is free and can be used for downloading data. It is provided on the green “resources” USB memory stick provided with the sampler.

Airodis Full Version Refer to the Airodis How To Order Guide

Airodis can be used to automatically or manually download data from the sampler. More information is available at www.airodis.com

1.4.2 Consumables/Spares

Part Number Description

ECO-200030-1 Glass Container with teflon caps with PUF material & SS Screens

ECO-200030-4 Quartz Filters for PUF (Box of 25)

Page 13

1.5 How to order a MegaVol 3000

Requirement Part Number Description

The customer requires a MegaVol sampler from 120 – 150m3/h

The following unit must be ordered for standard particulate sampling

MegaVol 3000 sampler E040010 MegaVol 3000 sampler

The customer requires a TSP inlet head!

The size selective inlet (SSI) below must be selected

TSP (Total suspended particulates)

ECO-HVS3000-01 Inlet head for TSP sampling

What optional accessories does the customer require?

Add from the list below any accessories the customer requires

Wind speed/direction sensor WITH

attachments

ECO-HVS3000-40 Model 034B wind speed direction sensor (Includes Sensor, mounting support and sensor cable)

Wind speed/direction sensor WITHOUT attachments

ZMM-034B Model 034B wind speed direction sensor

Wind sensor cable CAB-HVS300007 3m Cable for 034B Sensor

Wind sensor mounting arm HAR-HV3002 HiVol Mounting Arm for 034B Sensor (onto chassis)

Muffler ECO-HVS3000-51 Muffler reduces the sound of the HiVol

How to order guide HVS3000 High Volume Air Samplers 2 .0

Page 14

Calibration orifice plate E040010-01 Allows calibration of HiVol PUF when used with a manometer

300 mm U Tube Manometer

ATM-1000 U tube manometer uses water to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Manometer

ECO-HVS3000-24 Digital manometer to measure vacuum pressure of HiVol pump (used with calibration orifice plate)

Battery Operated Digital Barometer AIR72498101

ECO-HVS3000-25 Digital Barometer used to measure ambient pressure

0-50 deg. C Max/Min Mercury Thermometer

ATM-1003

1.5.1 Download Software

How do I download data off the HVS3000?

Airodis Demo Ecotech’s Airodis Demo software is free and can be used for downloading data. It is provided on the green “resources” USB memory stick provided with the sampler.

Airodis Full Version Refer to the Airodis How To Order Guide

Airodis can be used to automatically or manually download data from the sampler. More information is available at www.airodis.com

1.5.2 Consumables/Spares

Part Number Description

ECO-HVS3000-52 Spare Filter Cassette

Page 15

This page is intentionally blank

Error! No text of specified style in document. Page 17

1492 Ferntree Gully Road, Knoxfield VIC Australia 3180 Phone: +61 (0)3 9730 7800

Fax: +61 (0)3 9730 7899 General email: [email protected]

International support: [email protected]

www.ecotech.com