410 91 006 Issue 3 20 th October 2008 ECN 542 G:\DOCUMENT CONTROL\Manuals\Flame\410\41091006 Digital Interface & Lineariser Instructions Issue 3.doc Digital Interface/Lineariser Module for M410 Flame Photometer Fitting & Operating Instructions Copyright 2008 Sherwood Scientific Ltd. All rights reserved.

Upload: others

Post on 30-Apr-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

410 91 006 Issue 3 20th October 2008 ECN 542 G:\DOCUMENT CONTROL\Manuals\Flame\410\41091006 Digital Interface &

Lineariser Instructions Issue 3.doc

Digital Interface/Lineariser

Module for

M410 Flame Photometer

Fitting & Operating Instructions

Copyright 2008 Sherwood Scientific Ltd. All rights reserved.

Page 2: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 2 -

Intended Use This manual gives instruction for set up and use of the Model 410 Flame Photometer Digital Interface/Lineariser Module. The module provides a serial printer interface to the Model 410 and if selected will also linearise results obtained for Sodium over the range of 0.5 to 20ppm. The Module has no user replaceable parts: do not attempt to dis-assemble the module. Sherwood Scientific Limited and its authorised Distributors consider themselves responsible for the effects of safety, reliability and performance of the Module only if: -

• Assembly operations, extensions, re-adjustments, modifications or repairs are carried out by persons authorized by them.

• The electrical installation of the relevant room complies with IEC requirements or local regulatory codes.

• The equipment is used in accordance with the instructions for use.

The information contained in this manual was correct at the time of going to print. However, Sherwood Scientific’s policy is one of continuous product improvement and the right to change specifications, equipment and maintenance procedures at any time, without notice, are reserved. This manual is copyrighted, and all rights are reserved. No part of this manual may be reproduced by any means or in any form without prior consent in writing. Sherwood Scientific Ltd, 1 The Paddocks, Cherry Hinton Road, Cambridge, CB1 8DH, United Kingdom Tel: +44 1223 243444 Fax : +44 1223 243300 Email [email protected] Website www.sherwood-scientific.com

Page 3: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 3 -

Contents Page

Intended Use ................................................................................................. 2

1 Introduction ............................................................................................. 4

1.1 Introduction .................................................................................... 4

2 Installation .............................................................................................. 5

2.1 Unpacking ...................................................................................... 5

2.2 Assembly ........................................................................................ 6

3 Specification............................................................................................ 8

3.1 Measurement Ranges ...................................................................... 8

3.2 Communication Settings ................................................................. 8

3.3 Environmental Conditions .............................................................. 8

Temperature ................................................................................... 8

Humidity ........................................................................................ 8

3.4 Size ................................................................................................ 9

3.5 Weight ........................................................................................... 9

4 Operating Instructions ........................................................................... 10

4.1 Controls and Indicators. ................................................................ 10

B, C, S, R ..................................................................................... 10

Print ............................................................................................. 10

Selector button ............................................................................. 10

Print button .................................................................................. 10

4.2 Initial Adjustment ......................................................................... 11

With a Computer .......................................................................... 11

Setting the Date & Time ............................................................... 11

With A Printer .............................................................................. 12

Setting the Date & Time ............................................................... 12

4.3 Calibration ................................................................................... 13

Lineariser Off ............................................................................... 13

Lineariser On ............................................................................... 14

4.4 Using the Module ......................................................................... 15

With A Printer .............................................................................. 15

With A Computer ......................................................................... 16

4.5 Switching the Linearisation Function On andOff ........................... 17 5 Troubleshooting..................................................................................... 18

5.1 Printer LED Flashing .................................................................... 18

5.2 Output Does Not Equal Display .................................................... 18 5.3 Date & Time Not Reported Correctly ............................................ 18

6 Spares and Accessories .......................................................................... 19

6.1 Ordering Information .................................................................... 19

6.2 Spares and Accessories ................................................................. 19

Sherwood Scientific Limited Product Warranty Statement ........................... 20 Appendix A ................................................................................................. 22

HyperTerminal ...................................................................................... 22

Page 4: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 4 -

1 Introduction

1.1 Introduction The Digital Interface/Lineariser Module is a plug-in module, designed to be fitted into the front of a Model 410 Flame Photometer. The module consists of an analogue to digital converter and RS232 serial output socket. Any printer with the ability to accept data at 9600 baud or computer may be connected. This facility is available to all existing users as the module fits directly to the front of the Model 410 underneath the logo plate. The module presents two buttons. One enables the user to toggle between Blank, Calibrate, Sample and Repeat to select the current operation description to be printed alongside the value displayed; the other is the print command which prints the displayed value with the time, date and sequence number. If your instrument already has a lineariser fitted, this module physically replaces it (its circuitry also incorporates the linearisation algorithm). This will correct for Sodium values only up to 20ppm. If linearisation is not required, the function can be disabled before fitting the module to the instrument.

Page 5: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 5 -

2 Installation

2.1 Unpacking 1. Unpack the module and accessories.

2. Check all items for damage.

3. Check that all the items on the Accessory List have been delivered. Contact your Sherwood Scientific distributor if you have any problems.

4. The Module is shipped with the following items:

Accessory List CAT. NO. ITEM QUANTITY

410 86 001 Module 1 410 09 003 Lead, M410 to Printer/Computer 1 410 91 006 Installation/Operator Manual 1

Page 6: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 6 -

2.2 Assembly To assemble the module to the Model 410, proceed as follows:-

1. Remove the Logo plate (item 1, Fig. 2.2) from the instrument. Use a small flat bladed screwdriver to release the locking tabs at the top and bottom centre and gently pull it away.

If a lineariser (item 2, Fig. 2.2) is already fitted it must be removed, the safest way to do this is to remove the front panel assembly.

2. Remove the front panel, by unscrewing the six screws securing it in place. Two on the bottom front edge and four along the top back edge (two of which are recessed).

3 Gently pull the front panel away from the unit, taking care not to strain the wires. The fuel control knob will be pulled off in the process.

4 The two locating pegs for the lineariser can now be located at the top of the PCB. Gently and evenly push them both to release the lineariser from the PCB.

5 Refit the front panel assembly and fuel knob.

6 The module is supplied with the lineariser enabled, if you do not require this function:-

Interface upto #21231 Before fitting the interface slide the red switch to the right (when viewed from the top with the black overlay nearest to you).

Interface from #21807 After fitting the interface into the instrument, turn on the instrument and after the ignition sequence press the ‘Select’ button while moving the ‘Filter Selector’ to K or Ca. When ‘Select’ is released the buzzer will stop and ‘C’ will no-longer be illuminated.

Page 7: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 7 -

7 Fit the new module by aligning the pegs in the locating holes of the PCB and pushing the module fully home. Be careful to align the gold pins so they do not get bent before pushing too hard.

8 Connect the printer/computer cable by pushing the mating end onto the socket at the left-hand end of the module.

2.2 Assembly continued

Figure 2.2 1. Logo Plate 2. Lineariser Module

Page 8: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 8 -

3 Specification

3.1 Measurement Ranges With Lineariser switched on (C illuminated on module)

Na 0.5 to 20ppm linear

(concentration entering the flame photometer after dilution). For other analytes see the Model 410 Operator’s Manual.

3.2 Communication Settings

RS232 to Serial Printer Baud rate 9600 Data bits 8 Parity None PC Serial COMs Port – HyperTerminal (see Appendix A) As above and with Stop Bits 1 Flow Control None

3.3 Environmental Conditions

Temperature Operating +10°C to +35°C; Transportation -40°C to +45°C. Humidity Operating 85% maximum at +35°C. Transportation 95% maximum at +45°C (non-condensing).

The instrument specification will be unaffected by an ambient temperature change of 4°C (or less) per hour, within the range +10°C to +35°C, with a maximum of 7°C shift during 8 hours.

Page 9: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 9 -

3.4 Size Overall, including printer connector and signal pins

35mm high x 210mm wide x 26mm deep.

3.5 Weight 88g, module only.

Page 10: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 10 -

4 Operating Instructions

4.1 Controls and Indicators.

B, C, S, R When B is illuminated pressing the print button will print out the displayed value with the word blank and the date and time.

When C is illuminated pressing the print button will print out the displayed value with the word calibration and the date and time.

When S is illuminated pressing the print button will print out the displayed value with the word sample and the date and time.

When R is illuminated pressing the print button will print out the displayed value with the word repeat and the date and time.

Print This LED is constantly illuminated. If the print button is pressed without a printer connected, the LED will flash.

Selector button Each press of the select switch will cause the buzzer to sound and the next LED in the sequence to illuminate.

Print button Each press of the print button will cause the buzzer to sound and the printer to print out.

Page 11: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 11 -

4.2 Initial Adjustment

With a Computer Connect the module to a PC serial port, then access HyperTerminal and use these settings:-

9600 baud 8 bit No parity Stop bit 1 Flow Control None

See Appendix A for details on accessing HyperTerminal. Setting the Date & Time Type ‘+++’ in to HyperTerminal and the following menu will appear:-

Flame Photometer Data Output Rev x.xx Serial No. xxxxx Checksum xxxxxx Normal. Present value 1/slope xx.xxx, intercept x.xxx Lineariser Present value 1/slope xxx.xxx intercept x.xxx

Enter menu item number + newline 1 Calibrate 2 Check Calibration 3 Set Clock (not Bluetooth) 4 or q to Quit Enter ‘3’ and follow the instructions:-

Enter date and time in format. dd:mm:yy hh:mm:ss A message will be returned similar to below:-

Clock set as 02-Feb-06 14:14:03

Enter menu item number + newline 1 Calibrate 2 Check Calibration 3 Set Clock (not Bluetooth) 4 or q to Quit

Page 12: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 12 -

With A Printer Setting the Date & Time Connect the printer to the instrument with the cable provided and switch on the printer. Make sure that the printer is set to: -

9600 baud 8 bit No parity Stop bit 1

Press and hold down the ‘Print’ button on the module (right-hand button) whilst switching on the flame photometer. When the start-up sequence has completed release the button. The buzzer will sound, the ‘printer symbol’ will be flashing, ‘B’ will be illuminated and the following will be printed:- Sherwood Printer option Vx.xx Clock set as 02-Feb-06 15:00:29 Press the ‘Print’ button to increment the minutes. To decrement the minutes press the ‘Select’ button to illuminate ‘C’, then press the ‘Print’ button. Press the ‘Select’ button to illuminate ‘S’, now when the ‘Print’ button is pressed the hours will increment. To decrement the hours press the ‘Select’ button to illuminate ‘R’, then press the ‘Print’ button. To exit this mode wait 30 seconds and the instrument will revert to normal operation with the ‘B’ and ‘Printer’ symbol illuminated. The printer will print: Sherwood Printer option Vx.xx

Page 13: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 13 -

4.3 Calibration Only required when the module is supplied separately to the instrument. Lineariser Off Ensure the element select switch on the flame photometer is set to K, Ca or Li, connect the module to a PC running HyperTerminal with the lead provided and switch on the flame photometer. Enter ‘+++’ and then 1 into HyperTerminal to enter the calibration mode, the following message is returned. Calibrate Normal current l/slope xx.xxx, intercept x.xxx Enter reading + newline when DPM stable or q to abort When the number on the instrument display has stablised type it into HyperTerminal and press return. A total of 10 numbers will be presented, after the last one is entered new values for slope and intercept will be displayed in HyperTerminal and the menu will reappear. Enter q to exit set-up mode.

Page 14: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 14 -

Lineariser On Ensure the element select switch on the flame photometer is set to Na, and then connect the module to a PC running HyperTerminal with the lead provided and switch on the flame photometer. Enter ‘+++’ and then 1 in to HyperTerminal to enter the calibration mode, the following message is returned. Calibrate Lineariser Present value l/slope xx.xxx, intercept x.xxx Enter reading + newline when DPM stable or q to abort When the number on the instrument display has stablised, type it into HyperTerminal and press return. A total of 4 numbers will be presented, after the last one is entered new values for slope and intercept will be displayed in HyperTerminal and the menu will reappear. Enter q to exit set-up mode.

Page 15: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 15 -

4.4 Using the Module

With A Printer Connect the printer to the instrument with the cable provided and switch on the printer. Make sure that the printer is set to: -

9600 baud 8 bit No parity Stop bit 1

Switch on the flame photometer. When the start-up sequence has completed the module will be energized, this is indicated by the illumination of the printer symbol, ‘B’ for blanking and ‘C’ (if the lineariser is selected). The following will be printed:- Flame Photometer Data Output Rev x.xx Serial Number xxxxx Aspirate the blank solution and adjust the zero control to get 000 on the display. When the display is stable, press the print button under the printer symbol; the printer will print out:- 16-Aug-06 09:01:45 Sn 1 Blank xx Next aspirate the top calibration standard and press the selector button once to illuminate ‘C’. Adjust reading to the required setting using the fine (and coarse) controls. When the display is stable, press the print button, to print:- 16-Aug-06 09:02:36 Sn 2 Calib xx Aspirate the sample press the selector button once to illuminate ‘S’. When the display is stable press the print button, the printer will print out:- 16-Aug-06 09:05:24 Sn 3 Sample xx

Page 16: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 16 -

Using the Module with A Printer - continued

Aspirate the next sample and press print when the display has stablised. The print out will show the result and incremented sequence number.

16-Aug-06 09:06:01 Sn 4 Sample xx If a sample is to be repeated, you may repeat the sequence number by pressing the select button to illuminate ‘R’. Aspirate the sample again and press print when the display is stable, ‘S’ will illuminate the print out will show:-

16-Aug-06 09:06:59 Sn 4 Repeat xx To re-set the sequence number, press and hold down both the Select and Print buttons for more than 0.5s. The buzzer will sound. No change will be observed in the LED’s and the printer will not print. When the Print button is next pressed the Sequence number printed will be 1.

With A Computer Connect the computer serial port to the instrument with the cable provided and switch on the computer. Open HyperTerminal on the computer (see Appendix A) and use the following for the communication settings: -

9600 baud 8 bit No parity Stop bit 1 Flow Control None

Switch on the flame photometer. When the start-up sequence has completed the module will be energized, this is indicated by the illumination of the printer symbol, ‘B’ for blanking and ‘C’ (if the lineariser is selected). The following will be displayed on the computer:-

Flame Photometer Data Output Rev x.xx Serial No. xxxxx Operation and output are as above from this point onward.

Page 17: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 17 -

4.5 Switching the Linearisation Function

On and Off To switch the Lineariser function on, press and hold the ‘Select’ button while moving the ‘Filter Selector’ to Na. When the ‘Select’ button is released the buzzer will stop and ‘C’ will be illuminated.

The ‘C’ will remain illuminated no matter what the position of the filter holder, but the Lineariser only operates when Na is selected.

To switch off the Lineariser, press and hold the ‘Select’ button while moving the ‘Filter Selector’ from Na to K. When the ‘Select’ button is released the buzzer will stop sounding and the ‘C’ will no longer be illuminated.

Page 18: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 18 -

5 Troubleshooting

5.1 Printer LED Flashing Printer or Computer not switched on or connected. Both the Select and Print switch are inoperative when the Printer LED is flashing. Make sure the Printer or Computer is switched on and the interface cable is securely connected, and then switch the instrument off and on again. If fault persists contact your Sherwood Scientific Distributor.

5.2 Output Does Not Equal Display

Perform Calibration as detailed in Section 4.3. There may always be a difference of 1 for high values. If fault persists contact your Sherwood Scientific Distributor.

5.3 Date & Time Not Reported Correctly Set clock as detailed in Section 4.2 If fault persists contact your Sherwood Scientific Distributor.

Page 19: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 19 -

6 Spares and Accessories

6.1 Ordering Information

When ordering spares or accessories for your instrument, please give the following information to your Sherwood Scientific distributor.

Instrument Serial No.

Catalogue No. of Part (Cat. No.)

Description

Quantity required

This will ensure that your order is dealt with quickly and efficiently.

The number shown in the third column (Quantity) is the quantity of items that are supplied against the stated Catalog Number. If the quantity is greater than 1, then only multiples of that quantity can be supplied.

6.2 Spares and Accessories

Serial Number Item Quantity 410 09 003 Lead, M410 to

Printer/Computer 1

Page 20: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 20 -

Sherwood Scientific Limited Product Warranty Statement _______________________________________________________________

Warranty Term: 12 Months Sherwood Scientific Ltd (Sherwood) warrants, subject to the conditions itemised within this document, through either Sherwood personnel or personnel of its authorised distributors, to repair or replace free of all charges, including labour, any part of this product which fails within the warranty time specified above, appertaining to this particular product. Such failure must have occurred because of a defect in material or workmanship and not have occurred as a result of operation of the product other than in accordance with procedures described in the instructions furnished with this product. Conditions and specific exceptions that apply to the above statement are as follows: 1. End-user warranty time commences on the date of the delivery

of product to end-user premises. 2. ‘Free of all charges’ statement applies only in areas

recognised by Sherwood as being serviced either directly by its own personnel, or indirectly through personnel of an authorised distributor. Products purchased outside these areas requiring service during the warranty period will incur charges relative to the travel/transit costs involved. However, products purchased in such areas will be serviced during the warranty period free of all charges providing they are returned, carriage paid, to either Sherwood or by pre-arrangement to an authorised Sherwood distributor.

3. All maintenance (other than operator maintenance as described in the instructions), repairs or modifications have been made by Sherwood or Sherwood authorised personnel.

4. This product has where applicable been operated using Sherwood specified supplies and reagents.

Page 21: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 21 -

5. Sherwood reserves the right to make any changes in the

design or construction of future products of this type at any time, without incurring any obligation to make any changes whatsoever to this particular product.

6. Reagents, supplies, consumables, accessories and user maintenance items are not included in this warranty.

7. Repairs or replacement of any part failing due to abnormal conditions including the following, are excluded from this warranty:

a. Flood, lightning, earthquake, tornado, hurricane, or any other natural or man-made disaster.

b. Fire, bombing, armed conflict, malicious mischief or sprinkler damage.

c. Physical abuse, misuse, sabotage or electrical surge. d. Damage incurred in moving the product to another

location. 8. User agrees to permit Sherwood personnel or personnel of its

authorised distributor to make changes in the product which do not affect results obtained, but do improve product reliability.

Representations and warranties purporting to be on behalf of Sherwood made by any person, including distributors and representatives of Sherwood, which are inconsistent or in conflict with the terms of this warranty (including but not limited to the limitations of the liability of Sherwood as set forth above), shall not be binding upon Sherwood unless reduced to writing and approved by an officer of Sherwood Scientific Ltd. Except for the obligations specifically set forth in this warranty statement, in no event shall Sherwood be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort or any other legal theory and whether advised of the possibility of such damages. Neither Sherwood nor any of its third party suppliers makes any other warranty of any kind, whether expressed or implied, with respect to Sherwood Products. Sherwood Scientific Ltd., 1 The Paddocks, Cherry Hinton Road, Cambridge, CB1 8DH, England

Page 22: Digital Interface/Lineariser Module for M410 Flame ... ma… · Digital Interface/Lineariser Module 410 91 006 Issue 3 20 th October 2008 ECN 542 - 2 - Intended Use This manual gives

Digital Interface/Lineariser Module

410 91 006 Issue 3 20th October 2008 ECN 542 - 22 -

Appendix A

HyperTerminal This program is available in all versions of windows software. To access HyperTerminal and set it up to communicate with your new module:- Select All Programs, Accessories, Communications HyperTerminal New Connection Name (e.g. M410 Flame) Coms1 Port Settings Bits per Second 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None Apply