detector r&d: j-parc-e16
DESCRIPTION
Detector R&D: J-PARC-E16. K. Ozawa (Univ. of Tokyo) for the E16 collaboration. Condensates and Spectrum. We can link condensates and vector meson spectrum. T.Hatsuda and S. Lee, PRC 46 (1992) R34. The relation is establish ed robustly. Average of Imaginary part of P ( w 2 ) - PowerPoint PPT PresentationTRANSCRIPT
Detector R&D: J-PARC-E16
K. Ozawa (Univ. of Tokyo) for the E16 collaboration
Condensates and Spectrum
2008/12/06 Nagoya, K. Ozawa 2
We can link condensates and vector meson spectrum.
q
q
Vacuum Vacuum
QCD sum rule
Average of Imaginary part of P(w2)
vector meson spectral function
T.Hatsuda and S. Lee,PRC 46 (1992) R34
Prediction
Spectrum
mV
The relation is established robustly.
Assume
03.0;10
*
B
V
V
mm
vector meson spectral function
Experimental results Model Calculation
Mass Shift:mf = m0 (1 - /0) for = 0.03
Average of measured spectra
p
Calculate amout of quark condensate using QCD sum rule.
Next Experiment
Need large statics
2008/12/06 Nagoya, K. Ozawa
New Spectrometer
5 times larger acceptance for pairsE16 SpectrometerKEK Spectrometer
Cope with 10 times larger beam intensity!!2 times larger cross section
Total, 100 times higher statistics!! 3
Nagoya, K. Ozawa2008/12/06
Major components
GEM Tracker
Gas Cherenkov for e-ID
Magnet modification
EM Calorimeter
Prototype is made and being tested
4
GEM TrackerGas Cherenkov
for e-ID
GEM TRACKER
2008/12/06 Nagoya, K. Ozawa 5
Nagoya, K. Ozawa2008/12/06
Required Resolution• Momentum and mass
resolution are evaluated based on KEK knowledge.– Position resolution:
• 300 mm for E325• 50 mm, 100 mm, 200 mm, and
300 mm for J-PARC– Multiple scattering
• Radiation length of detectors are increased for GEM foils
– Larger acceptance for J-PARC
To have the improved mass resolution,Target Resolution is 100 mm It can be achieved 0.7 mm pitch and strip charge information.
Momentum Resolution [GeV/c]
mass res. v.s. position res.[mm]
J-PARC
KEK
KEK300 mm200 mm100 mm 50 mm
6
2008/12/06 Nagoya, K. Ozawa
GEM Tracker• To cover large acceptance and
cope with high counting rate, 3 layers of GEM trackers are used.
• Similar to COMPASS detector– Use 3 layers in magnetic field– Extend to large acceptance
• Challenge : – Long term stability– Mechanical support with low
radiation length– Readout
Collaboration with KEK
COMPASS detector(NIM A535, 314)
Rate issue:5 kHz/mm2 is expected at J-PARCwith 700 mm pitch x 100mm height
COMPASS detector is workingUp to 25 kHz/mm2 (400 mm pitch)GEM detector will work
7
Kapton(d=50μm)
Cupper(d=5μm)
2008/12/06 Nagoya, K. Ozawa
GEM and Read outCollaboration with KEK
• 2-D strip readout configuration
NIM A425(1999)254
8
• GEM foils made in Japan (SciEnergy)
Ar-CO2
Japanese
CERN
Relative Gain with 3 GEM foils
2008/12/06 Nagoya, K. Ozawa
R&D @ TokyoPurpose:
Develop a GEM trackerEvaluate specifications
Position resolutionEfficiencyRate dependence
Current Configuration:3 GEM foilsp-10 gas2-D strip
Both side0.8 mm pitchCopy of KEK’s
9
2008/12/06 Nagoya, K. Ozawa
SignalsWe can see signals from both sides.Signal from bottom surface is distorted.
Already known problem by KEK group.
Strips on top surface Strips on bottom surface
TOP
Bottom
Bottom2
Bottom1TOP1
TOP2
10
2008/12/06 Nagoya, K. Ozawa
Sum
Sum of 3 strips looks reasonable distribution.
Check with X-ray
Strip1 Strip2 Strip3
Fe-55 X-ray Source
11
Position distribution is almost reasonable.
Position
Beam test is done.Results of resolution will be appeared soon.
GAS CHERENKOV
2008/12/06 Nagoya, K. Ozawa 12
Nagoya, K. Ozawa2008/12/06
Used @ KEK-PS E325
Gas Cherenkov Detector• Electron Identification using gas cherenkov
• Used for low momentum electron
Photo Cathode + GEM for amplificationNo Mirror
– Mirror and PMT, traditionally• Difficulty for Large acceptance
Requirement of large acceptanceat J-PARC E16 experiment
• CSI photo-cathod– UV sensitive (6 eV, 200nm)– High quantum efficiency
13
Nagoya, K. Ozawa2008/12/06
Measurements of Q.E.
• We got a consistent result with existing data.• Based on this measurements, the number of photo-electron
with 84 cm long radiator is estimated as 65.
Existing data by Weizmann Inst.
14
Nagoya, K. Ozawa2008/12/06
Old beam test @ Hiroshima• Operation
– Pure CF4 (cosθc=0.035)– CsI GEM
• 150V– Other GEM
• 490V (~104)– Water ~ 1ppm
1*1cmReadout Pad5x5 used
Electrons from ionization
Light Shield
• Inverse field• Light shade ON
– dE/dx (1mm)• Light shade OFF
– dE/dx (1mm) + Light
15
Nagoya, K. Ozawa2008/12/06
ResultsInverse field, light shield on, dE/dx (1mm) OnlyInverse field, light shield off, dE/dx (1mm) + Light
160 20 40 60 80 [Charge]
Arbi
trary
Uni
t
7 fc
Clear signal for energy loss
10 fc
Small difference, statisticallyIt can be Cherenkov origin.
New R&D is underway at RIKEN.Results will be appeared soon.
2008/12/06 Nagoya, K. Ozawa
Summary• For J-PARC E16, a GEM based spectrometer is
proposed to cope with high interaction rate and have large acceptance.
• R&D has started for J-PARC at Tokyo and RIKEN. GEM tracker with 2-D strip read out is being developed. First brief result of R&D is appeared.
• Cherenkov counter using CSI photocathode and GEM readout is the essential part to extend the acceptance. R&D is on-going.
17
Back up
2008/12/06 Nagoya, K. Ozawa
Issue: counting Rate• Interaction rate is 106 Hz at KEK (x10 @J-PARC)• However, beam halo can not be ignored• For example, actual condition at KEK is following.
– 350 kHz at the most forward cell of Drift Chamber• At radius of 200 mm and the horizontal angle of 6°• 3.5mm width and 220 mm height
– Mostly from beam halo• Extrapolate to J-PARC
– 10 times higher beam intensity– shorter beam-extraction duration– 3.5 MHz is expected.– 10 times finer segments are required
• 0.7 mm pitch x 100mm height
That’s the main issue for spectrometer design.We have to develop the detector which cope with 10 times larger rate.
19
2008/12/06 Nagoya, K. Ozawa
Detectors in high counting• MWPC limitation
– Wire spacing: 1~2 mm– Gain dropping @ high rate
• Micro strip gas chamber – Discharge problem
• Micromegas– Another candidate
• GEM– Flat gain up to 105 Hz/mm2
– I like flexibility of configuration– Good characteristics of signal
• Signal is generated by electron • Not by ion• No ion tail and pole cancellation
electronics
I took these ideas and figures from F. Sauli’s presentation at XIV GIORNATE DI STUDIO SUI RIVELATORI Villa Gualino 10-13 Febbraio 2004
GEM
MWPC
104 105
20
What can be achieved?
2008/12/06 Nagoya, K. Ozawa 21
Pb
fModified f
[GeV/c2]
f from Proton
Invariant mass in medium
ff
fff
ff
f
p dep.
High resolution
calculate quark condensate
Nagoya, K. Ozawa2008/12/06
Pictures from PHENIXsignal electron
partner positronneeded for rejection
In PHENIX IRGlobe box
Evaporate machine
22
Nagoya, K. Ozawa 232008/12/06
CSI photo cathode
TransmissiveBy Weitzman
• Transmissive type is used– Suitable with GEM – Relatively high quantum
efficiency– Low photon feedback
CSI Q. E.5 10 15
[eV]
CsIAuNiCuKaptonCu
Vapor deposition on GEMBy Hamamatsu
Nagoya, K. Ozawa2008/12/06
In reality
24