Page 1: DESIGN GUIDE - Sub-Zero

ICB REVISED 9 / 2019

DES IGN GU IDE

Page 2: DESIGN GUIDE - Sub-Zero

Features and specifications are subject to change at any time without notice.

Throughout this guide, dimensions may vary by ± 3 mm.

TA B L E O F C O N T E N T S

3 M S E R I E S O V E N S

15 E S E R I E S O V E N S

27 C O N V E C T I O N S T E A M O V E N S

32 S P E E D O V E N S

37 M I C R O W A V E O V E N S

42 W A R M I N G D R A W E R S

47 I N D U C T I O N C O O K T O P S

52 G A S C O O K T O P S

56 M O D U L E C O O K T O P S

64 C O F F E E S Y S T E M S

69 C U P W A R M I N G D R A W E R S

73 VA C U U M S E A L D R A W E R

77 D U A L F U E L R A N G E S

82 S E A L E D B U R N E R R A N G E T O P S

86 O U T D O O R G R I L L S | M O D U L E S | A C C E S S O R I E S

97 C O O K T O P V E N T I L AT I O N

108 D O W N D R A F T V E N T I L AT I O N

113 P R O V E N T I L AT I O N

120 W O L F W A R R A N T I E S

Page 3: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 3

M Series Built-In Ovens

Four striking looks are just the beginning. Superior perfor-mance features include our advanced Dual VertiCross™ convection fan system, touch-screen controls, convenient preset cooking programs, and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M series ovens can be installed in a standard or flush inset application.

M SERIES OVENS

UPPER OVEN LOWER OVEN

M SERIES OVENS

TRANSITIONAL

ICBSO30PM/S/PH

ICBSO30CM/B

ICBSO30TM/S/TH

ICBDO30PM/S/PH

ICBDO30CM/B

ICBDO30TM/S/TH

PROFESSIONAL

CONTEMPORARY

ICBSO30CM/S

ICBDO30CM/S

Page 4: DESIGN GUIDE - Sub-Zero

4 | English

M SERIES OVENS

M Series Built-In Ovens

TRANSITIONAL SINGLE OVEN

TRANSITIONAL DOUBLE OVEN

OPEN OVEN DOOR584 mm

BEHIND FRAME

723mm

686mm

65mm

46 mm

543mm

22mm

36 mmCONDUITCHANNEL

218mm

51 mm

759 mm

724 mm

OPEN OVEN DOOR

584 mmBEHIND FRAME

1291mm

1254mm

65mm

46 mm

543mm

22mm

36 mmCONDUITCHANNEL

218mm

51 mm

759 mm

724 mm

Page 5: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 5

M SERIES OVENS

M Series Built-In Ovens

PROFESSIONAL SINGLE OVEN

OPEN OVEN DOOR584 mm

BEHIND FRAME

723mm

686mm

83mm

46 mm

543mm

22mm

36 mmCONDUITCHANNEL

218mm

51 mm

759 mm

724 mm

UPPER OVEN LOWER OVEN

OPEN OVEN DOOR

584 mmBEHIND FRAME

1291mm

1254mm

759 mm

46 mm

543mm

83mm

22mm

36 mmCONDUITCHANNEL

218mm

51 mm

724 mm

PROFESSIONAL DOUBLE OVEN

Page 6: DESIGN GUIDE - Sub-Zero

6 | English

M SERIES OVENS

OPEN OVEN DOOR

584 mmBEHIND FRAME

1291mm

1254mm

46 mm

543mm

22mm

36 mmCONDUITCHANNEL

218mm

51mm

759 mm

724 mm

OPEN OVEN DOOR584 mm

BEHIND FRAME

723mm

686mm

46 mm

543mm

22mm

36 mmCONDUITCHANNEL

218mm

51mm

759 mm

724 mm

M Series Built-In Ovens

CONTEMPORARY STAINLESS STEEL SINGLE OVEN

CONTEMPORARY STAINLESS STEEL DOUBLE OVEN

Page 7: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 7

M SERIES OVENS

OPEN OVEN DOOR

584 mmBEHIND FRAME

1291mm

1254mm

46 mm

543mm

25mm

36 mmCONDUITCHANNEL

218mm

51 mm

759 mm

724 mm

OPEN OVEN DOOR584 mm

BEHIND FRAME

723mm

686mm

46 mm

543mm

25mm

36 mmCONDUITCHANNEL

218mm

51 mm

759 mm

724 mm

M Series Built-In Ovens

CONTEMPORARY BLACK GLASS SINGLE OVEN

CONTEMPORARY BLACK GLASS DOUBLE OVEN

Page 8: DESIGN GUIDE - Sub-Zero

8 | English

M SERIES OVENS

Planning Information

The M series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 6 mm is required between the units. Location of the electrical supply within the oven opening may require additional cabinet depth.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Single Oven 115 kgDouble Oven 181 kg

TRIM OVERLAP

Top 25 mmBottom 0 mmSides 18 mm

DUAL INSTALLATION

Two 76 cm single M series ovens can be installed side by side in a standard or flush inset application. A dual instal-lation kit is required. To maintain appropriate airflow, the ovens must be installed into one opening. Any cosmetic or structural material placed between the ovens will impede airflow and is not recommended. Refer to the illustrations on the following pages.

The dual installation kit is available through an authorized Wolf dealer.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your spe-cific installation on the following pages. For ease of instal-lation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.

Performance may be compromised if the electrical supply is less than 220 volts.

The oven is supplied with a single phase and 3-phase convertible power inlet box. The wiring diagram covering the control circuit is provided with the oven.

ELECTRICAL REQUIREMENTS

SINGLE OVEN SINGLE PHASE 3-PHASE

Required Power Supply 220-240 V AC 50/60 Hz

380-415 V AC 50 Hz

Maximum Connected Load 4.2–4.8 kW 3.0–3.6 kW

DOUBLE OVEN SINGLE PHASE 3-PHASE

Required Power Supply 220-240 V AC 50/60 Hz

380-415 V AC 50 Hz

Maximum Connected Load 8.4–9.6 kW 4.2–4.8 kW

Page 9: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 9

M SERIES OVENS

M Series Single Oven

STANDARD INSTALLATION

E127mm

E

E

102mm

FRONT VIEWSIDE VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

591 mmOPENING

DEPTH

TOP VIEW

699 mmOPENINGHEIGHT

WOPENING WIDTH

OPENING WIDTH W

76 cm Model 724 mm

Page 10: DESIGN GUIDE - Sub-Zero

10 | English

M SERIES OVENS

M Series Single Oven

FLUSH INSET INSTALLATION

E127mm

102mm

FRONT VIEWSIDE VIEW

*25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.**22 mm for transitional, professional and contemporary stainless steel models and 25 mm for contemporary black glass model.***Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth.

730 mmFLUSH INSET

HEIGHT***

29 mm

3 mm

21 mm

610 mmFLUSH INSET

DEPTH

22 mmOR

25 mm**FINISHEDCLEATS*

WFLUSH INSET WIDTH***

TOP VIEW

E

E

FLUSH INSET WIDTH W

76 cm Model 765 mm

Page 11: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 11

M Series Double Oven

STANDARD INSTALLATION

E127mm

102mm

E

E

FRONT VIEWSIDE VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

1267 mmOPENINGHEIGHT

591 mmOPENING

DEPTH

WOPENING WIDTH

432 mmTYPICAL

TOP VIEW

OPENING WIDTH W

76 cm Model 724 mm

M SERIES OVENS

Page 12: DESIGN GUIDE - Sub-Zero

12 | English

M Series Double Oven

FLUSH INSET INSTALLATION

E127mm

102mm

FRONT VIEWSIDE VIEW

*25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.**22 mm for transitional, professional and contemporary stainless steel models and 25 mm for contemporary black glass model.***Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth.

1299 mmFLUSH INSET

HEIGHT***

29 mm

3 mm

21 mm

610 mmFLUSH INSET

DEPTH

22 mmOR

25 mm**FINISHEDCLEATS*

WFLUSH INSET WIDTH***

432 mmTYPICAL

TOP VIEW

E

E

FLUSH INSET WIDTH W

76 cm Model 765 mm

M SERIES OVENS

Page 13: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 13

M SERIES OVENS

E127mm

102mm

E127mm

102mm

E E

FRONT VIEWSIDE VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

TOP VIEW

591 mmOPENING

DEPTH

699 mmOPENINGHEIGHT W

OPENING WIDTH

M Series Single Oven

DUAL STANDARD INSTALLATION

DUAL OPENING WIDTH W

Two 76 cm Models 1486 mm

Page 14: DESIGN GUIDE - Sub-Zero

14 | English

M SERIES OVENS

E127mm

102mm

E127mm

102mm

FRONT VIEWSIDE VIEW

TOP VIEW

EE

FINISHEDCLEATS*

*25 mm minimum depth. Shaded areas will be visible and should be finished to match cabinetry.**22 mm for transitional, professional and contemporary stainless steel models and 25 mm for contemporary black glass model.***Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

730 mmFLUSH INSET

HEIGHT***

29 mm

3 mm

21 mm

610 mmFLUSH INSET

DEPTH

22 mmOR

25 mm**

WFLUSH INSET WIDTH***

M Series Single Oven

DUAL FLUSH INSET INSTALLATION

DUAL FLUSH INSET WIDTH W

Two 76 cm Models 1527 mm

Page 15: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 15

ICBSO24TE/S/TH

E Series Built-In Ovens

Stainless models feature a redesigned stainless steel touch-action control panel, helping to create great meals with ease, as well as adding a striking design feature to the kitchen. Smart technology gives the E series ten cooking modes, with Wolf’s innovative dual convection in single ovens and in the upper unit of double ovens. Wolf E series ovens are crafted of stainless steel. Tubular handles have been updated to match the rest of the new Wolf cooking appliance offering, providing a more cohesive look. E series ovens can be installed in a standard or flush inset application.

E SERIES OVENS

E SERIES OVENS

TRANSITIONAL

WARM LIGHT TEMP MODE TIMER TIME OFFOK

ICBSO2418TE/S/TH

ICBSO30CE/B/TH

ICBSO30TE/S/TH

ICBDO30TE/S/TH

ICBDO30CE/B/TH

ICBSO30PE/S/PH

ICBDO30PE/S/PH

PROFESSIONAL

CONTEMPORARY

Page 16: DESIGN GUIDE - Sub-Zero

16 | English

E SERIES OVENS

60 cm E Series Ovens

MODEL ICBSO2418TE/S/TH TRANSITIONAL SINGLE OVEN

MODEL ICBSO24TE/S/TH TRANSITIONAL SINGLE OVEN

OPEN OVEN DOOR

546 mmBEHIND FRAME

597mm

591mm

64mm

559 mm

460mm

22 mm

597 mm

OPEN OVEN DOOR

454mm

446mm

64mm

538 mm

360mm

22 mm

597 mm 546 mmBEHIND FRAME

WATER LIGHT TEMP MODE TIMER TIME OFFOK

Page 17: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 17

E SERIES OVENS

76 cm E Series Ovens

TRANSITIONAL SINGLE OVEN

603 mmBEHIND FRAME

708mm

759 mm

CONDUITCHANNEL 689

mm

70mm

76 mm

718 mm

559mm

244mm

225mm

25 mm

OPEN OVEN DOOR

OPEN OVEN DOOR

603 mmBEHIND FRAME

1280mm

1261mm

759 mm 70mm

CONDUITCHANNEL

718 mm

559mm

244mm

225mm

76 mm

25 mm

TRANSITIONAL DOUBLE OVEN

Page 18: DESIGN GUIDE - Sub-Zero

18 | English

E SERIES OVENS

76 cm E Series Ovens

PROFESSIONAL SINGLE OVEN

603 mmBEHIND FRAME

708mm

759 mm

CONDUITCHANNEL 689

mm

86mm

76 mm

718 mm

559mm

244mm

225mm

25 mm

OPEN OVEN DOOR

OPEN OVEN DOOR

603 mmBEHIND FRAME

1280mm

1261mm

759 mm

CONDUITCHANNEL

718 mm

559mm

244mm

225mm

76 mm

25 mm

86mm

PROFESSIONAL DOUBLE OVEN

Page 19: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 19

E SERIES OVENS

OPEN OVEN DOOR

603 mmBEHIND FRAME

1280mm

1257mm

759 mm 76mm

32 mm

CONDUITCHANNEL

76 mm

718 mm

559mm

244mm

225mm

OPEN OVEN DOOR

603 mmBEHIND FRAME

708mm

759 mm

32 mm

687mm

76mm

CONDUITCHANNEL

76 mm

718 mm

559mm

244mm

225mm

76 cm E Series Ovens

CONTEMPORARY SINGLE OVEN

CONTEMPORARY DOUBLE OVEN

Page 20: DESIGN GUIDE - Sub-Zero

20 | English

Planning Information

The E series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 6 mm is required between the units. Location of the electrical supply within the oven opening may require additional cabinet depth.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 6 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

60 cm Single Oven 68 kg76 cm Single Oven 115 kg76 cm Double Oven 181 kg

TRIM OVERLAP 60 cm MODEL 76 cm MODEL

Top 6 mm 13 mmBottom 0 mm 3 mmSides 17 mm 17 mm

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet. The 76 cm ovens are supplied with a terminal box convertible to single or 3-phase.

The wiring diagram covering the control circuit is provided with the oven.

ELECTRICAL REQUIREMENTS

60 cm SINGLE OVEN

Electrical Supply 220-240 V AC, 50 HzService 3400 WReceptacle grounding-type (earthed)Power Cord 1.8 m

ELECTRICAL REQUIREMENTS

76 cm SINGLE OVEN SINGLE PHASE 3-PHASE

Required Power Supply 220-240 V AC 50/60 Hz

380-415 V AC 50 Hz

Max Connected Load 4.4 kW 4.4 kWTotal Amps 19 19

76 cm DOUBLE OVEN SINGLE PHASE 3-PHASE

Required Power Supply 220-240 V AC 50/60 Hz

380-415 V AC 50 Hz

Max Connected Load 7.4 kW 5.1 kWTotal Amps 32 22

E SERIES OVENS

Page 21: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 21

E SERIES OVENS

60 cm E Series Oven

STANDARD INSTALLATION

E

FRONT VIEWSIDE VIEW

HOPENINGHEIGHT

546 mmOPENINGDEPTH*

TOP VIEW

562 mmOPENING WIDTH

*Does not include additional depth for the electrical connection.

OPENING HEIGHT H

ICBSO2418TE/S/TH 449 mm

ICBSO24TE/S/TH 591 mm

Page 22: DESIGN GUIDE - Sub-Zero

22 | English

E SERIES OVENS

E

603 mmFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

568 mmFLUSHINSET

DEPTH***22 mm

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

HFLUSH INSET

HEIGHT**

10 mm

3 mm

TOP VIEW

21 mm

FINISHEDCLEATS*

60 cm E Series Oven

FLUSH INSET INSTALLATION

FLUSH INSET HEIGHT H

ICBSO2418TE/S/TH 467 mm

ICBSO24TE/S/TH 603 mm

Page 23: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 23

76 cm E Series Single Oven

STANDARD INSTALLATION

E127mm

E

E

102mm

FRONT VIEWSIDE VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

610 mmOPENING

DEPTH

TOP VIEW

692 mmOPENINGHEIGHT

724 mmOPENING WIDTH

E SERIES OVENS

Page 24: DESIGN GUIDE - Sub-Zero

24 | English

E SERIES OVENS

E127mm

102mm

FRONT VIEWSIDE VIEW

*Will be visible and should be finished to match cabinetry.**25 mm for professional and transitional models and 32 mm for contemporary model.***Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth.

721 mmFLUSH INSET

HEIGHT***

19 mm

10 mm

24 mm

635 mmFLUSH INSET

DEPTHFINISHEDCLEATS*

772 mmFLUSH INSET WIDTH***

25 mmOR

32 mm**

TOP VIEW

981 mmTYPICAL

E

E

76 cm E Series Single Oven

FLUSH INSET INSTALLATION

Page 25: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 25

E SERIES OVENS

E127mm

102mm

E

E

FRONT VIEWSIDE VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

1264 mmOPENINGHEIGHT

610 mmOPENING

DEPTH

724 mmOPENING WIDTH

432 mmTYPICAL

TOP VIEW

76 cm E Series Double Oven

STANDARD INSTALLATION

Page 26: DESIGN GUIDE - Sub-Zero

26 | English

76 cm E Series Double Oven

FLUSH INSET INSTALLATION

E127mm

102mm

E

E

FRONT VIEWSIDE VIEW

*Will be visible and should be finished to match cabinetry.**25 mm for professional and transitional models and 32 mm for contemporary model.***Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth.

1292 mmFLUSH INSET

HEIGHT***

432 mmTYPICAL

19 mm

10 mm

24 mm

772 mmFLUSH INSET WIDTH***

635 mmFLUSH INSET

DEPTHFINISHEDCLEATS*

25 mmOR

32 mm**

TOP VIEW

E SERIES OVENS

Page 27: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 27

CONVECTION STEAM OVENS

Convection Steam Ovens

The legacy of the “combination oven” goes back decades, to innovative chefs in America and Europe who embraced the combination of air movement with superheated steam to achieve superior results—from breads and roasts to delicate fishes, seafood, and vegetables. Wolf combines the benefits of convection and steam for the most innovative steam oven on the market today. Virtually any dish prepared in a con-ventional oven, range, or microwave can also be prepared in the Wolf convection steam oven—with more control. Two widths and three distinct styles compliment the look of Wolf ovens, ranges, and cooktops. Convection steam ovens can be installed in a standard or flush inset application.

CONVECTION STEAM OVENS

TRANSITIONAL

ICBCSO30TE/S/TH

ICBCSO30TM/S/TH

PROFESSIONAL

ICBCSO30PE/S/PH

ICBCSO30PM/S/PH

ICBCSO30CM/B/TH

ICBCSO24TE/S/TH

CONTEMPORARY

ICBCSO30CMB

ICBCSO30CMS

Page 28: DESIGN GUIDE - Sub-Zero

28 | English

CONVECTION STEAM OVENS

OPEN OVEN DOOR

454mm

446mm

64mm

538 mm

360mm

22 mm

546 mmBEHIND FRAME

WWIDTH

Convection Steam Ovens

TRANSITIONAL

PROFESSIONAL

OPEN OVEN DOOR

454mm

446mm

83mm

538 mm

360mm

22 mm

759 mm 546 mmBEHIND FRAME

CONTEMPORARY

454mm

446mm

64mm

22 mm

759 mm

OPEN OVEN DOOR

538 mm

360mm

546 mmBEHIND FRAME

WIDTH W

60 cm Transitional 597 mm

76 cm Transitional 759 mm

Page 29: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 29

CONVECTION STEAM OVENS

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Performance may be compromised if the electrical supply is less than 220 volts.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz

Service 3800 W

Receptacle grounding-type (earthed)

Power Cord 1.8 m

Planning Information

The convection steam oven can be installed in a standard or flush inset application.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

60 cm Model 45 kg76 cm Model 45 kg

TRIM OVERLAP 60 cm MODEL 76 cm MODEL

Top 5 mm 5 mmBottom 0 mm 0 mmSides 18 mm 98 mm

Page 30: DESIGN GUIDE - Sub-Zero

30 | English

Convection Steam Oven

STANDARD INSTALLATION

E

FRONT VIEWSIDE VIEW

TOP VIEW

WOPENING WIDTH

546 mmOPENINGDEPTH*

*Does not include additional depth for the electrical connection.NOTE: Both 60 cm and 76 cm models require the same opening dimensions.

449 mmOPENINGHEIGHT

CONVECTION STEAM OVENS

OPENING WIDTH W

60 cm Model 562 mm

76 cm Model 562 mm

Page 31: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 31

Convection Steam Oven

FLUSH INSET INSTALLATION

E

WFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

22 mm

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

8 mm

3 mm

A

TOP VIEW

FINISHEDCLEATS*

568 mmFLUSHINSET

DEPTH***

460 mm FLUSH INSET

HEIGHT**

CONVECTION STEAM OVENS

FLUSH INSET WIDTH W A

60 cm Model 603 mm 21 mm

76 cm Model 765 mm 102 mm

Page 32: DESIGN GUIDE - Sub-Zero

32 | English

SPEED OVENS

Speed Ovens

The Wolf speed oven has features that make fast meals better meals. Available in 60 cm and 76 cm widths, they are designed to match Wolf transitional, professional, and contemporary products. The speed oven can be installed in a standard or flush inset application.

SPEED OVENS

TRANSITIONAL

ICBSPO30TM/S/TH

ICBSPO24TE/S/TH

ICBSPO30TE/S/TH

ICBSPO30PE/S/PH

ICBSPO30PM/S/PH

PROFESSIONAL

ICBSPO30CM/B/TH

CONTEMPORARY

Page 33: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 33

SPEED OVENS

WWIDTH

454mm

64mm

360mm

22 mm

OPENOVEN DOOR

538 mm

446mm

546 mmBEHIND FRAME

Speed Ovens

TRANSITIONAL

PROFESSIONAL

454mm

446mm

83mm

538 mm

360mmOPEN

OVEN DOOR

759 mm 546 mmBEHIND FRAME

22 mm

CONTEMPORARY

454mm

64mm

360mmOPEN

OVEN DOOR

538 mm

446mm

759 mm 546 mmBEHIND FRAME

22 mm

WIDTH W

60 cm Transitional 597 mm

76 cm Transitional 759 mm

Page 34: DESIGN GUIDE - Sub-Zero

34 | English

SPEED OVENS

Planning Information

The speed oven can be installed in a standard or flush inset application.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

If the speed oven is installed above or below a Wolf E series oven in a flush inset application, a 6 mm reveal is required.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

60 cm Model 57 kg76 cm Model 57 kg

TRIM OVERLAP 60 cm MODEL 76 cm MODEL

Top 5 mm 5 mmBottom 0 mm 0 mmSides 18 mm 98 mm

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Performance may be compromised if the electrical supply is less than 220 volts.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz

Service 2800 W

Receptacle grounding-type (earthed)

Power Cord 1.2 m

Page 35: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 35

SPEED OVENS

E

FRONT VIEWSIDE VIEW

NOTE: 60 cm and 76 cm models require the same opening dimensions.

449mm

OPENINGHEIGHT

584 mmOPENING

DEPTH

TOP VIEW

WOPENING WIDTH

Speed Oven

STANDARD INSTALLATION

OPENING WIDTH W

60 cm Model 562 mm

76 cm Model 562 mm

Page 36: DESIGN GUIDE - Sub-Zero

36 | English

SPEED OVENS

E

WFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

610 mmFLUSH INSET

DEPTH22 mm

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.

460mm

FLUSH INSETHEIGHT**

8 mm

3 mm

A

TOP VIEW

FINISHEDCLEATS*

Speed Oven

FLUSH INSET INSTALLATION

FLUSH INSET WIDTH W A

60 cm Model 603 mm 21 mm

76 cm Model 765 mm 102 mm

Page 37: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 37

PROFESSIONAL

CONTEMPORARY

MICROWAVE OVENS

Microwave Ovens

As true cooking instruments, Wolf microwave ovens have features that make fast meals better meals. The new drop-down door microwaves feature a door that hinges at the bottom. Drop-down door microwaves are designed to match Wolf transitional, professional, and contemporary products. Microwave ovens can be installed in a standard or flush inset application.

DROP-DOWN DOOR MICROWAVES

TRANSITIONAL

ICBMDD30TE/S/TH

ICBMDD30TM/S/TH

ICBMDD30PE/S/PH

ICBMDD30PM/S/PH

ICBMDD30CM/B/TH

ICBMDD24TE/S/TH

Page 38: DESIGN GUIDE - Sub-Zero

38 | English

MICROWAVE OVENS

546 mmBEHIND FRAME

OPEN OVEN DOOR

454mm

64mm

360mm

22 mm 538 mm

446mm

WWIDTH

WIDTH W

60 cm Model 597 mm

76 cm Model 759 mm

Drop-Down Door Microwave Ovens

TRANSITIONAL

PROFESSIONAL

OPEN OVEN DOOR

454mm

446mm

83mm

538 mm

360mm

22 mm

759 mm 546 mmBEHIND FRAME

CONTEMPORARY

546 mmBEHIND FRAME

OPEN OVEN DOOR

454mm

64mm

360mm

22 mm 538 mm

446mm

759 mm

Page 39: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 39

MICROWAVE OVENS

Planning Information

DROP-DOWN DOOR MICROWAVE

The drop-down door microwave oven can be installed in a standard or flush inset application.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Drop-Down Door Microwave 57 kg

TRIM OVERLAP 60 cm MODEL 76 cm MODEL

Top 5 mm 5 mmBottom 0 mm 0 mmSides 18 mm 98 mm

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50/60 Hz

Service 1600 W

Receptacle grounding-type (earthed)

Power Cord 1.2 m

Page 40: DESIGN GUIDE - Sub-Zero

40 | English

MICROWAVE OVENS

Drop-Down Door Microwave Oven

STANDARD INSTALLATION

E

FRONT VIEWSIDE VIEW

449 mmOPENINGHEIGHT

TOP VIEW

WOPENING WIDTH

*Does not include additional depth for the electrical connection.NOTE: Both 60 cm and 76 cm models require the same opening dimensions.

546 mmOPENINGDEPTH*

OPENING WIDTH W

60 cm Model 562 mm

76 cm Model 562 mm

Page 41: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 41

MICROWAVE OVENS

Drop-Down Door Microwave Oven

FLUSH INSET INSTALLATION

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

E

WFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

FINISHEDCLEATS*

25 mm

460 mm FLUSH INSET

HEIGHT**

8 mm

3 mm

A

TOP VIEW

571 mmFLUSHINSET

DEPTH***

FLUSH INSET WIDTH W A

60 cm Model 603 mm 21 mm

76 cm Model 765 mm 102 mm

Page 42: DESIGN GUIDE - Sub-Zero

42 | English

Warming Drawers

Wolf warming drawers are designed to take care of pre-pared foods until it is time to serve them. You can adjust the temperature, keeping moist foods moist and crisp foods crisp. Warming drawers are ideal for proofing dough. Drawer fronts are available to match the look of Wolf ovens and sealed burner rangetops. The integrated drawer front allows for a custom panel and handle.

WARMING DRAWERS

TRANSITIONAL

CONTEMPORARY

PROFESSIONAL

CUSTOM PANEL

WARMING DRAWER FRONTS

M / E SERIES

INTEGRATED

Page 43: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 43

578 mm

718 mm

229mm

264mm

A

BWWIDTH

546mm

OPEN DRAWER

DIMENSIONS

WARMING DRAWERS

Warming Drawers

DRAWER FRONT OPTIONS

Wolf warming drawer fronts allow for many design options, but the warming drawer itself will be the same for all appli-cations. A panel mounting kit is required when installing a custom panel. The panel mounting kit is available through an authorized Wolf dealer.

The 51 mm thick drawer front, in 76 cm and 91 cm widths, is designed to be installed below a sealed burner rangetop, so the panel aligns properly with the front of the rangetop. Dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a Wolf 91 cm oven or sealed burner rangetop.

DRAWER FRONT

MODEL W

76 cm Drawer Front 759 mm91 cm Drawer Front 911 mm

M SERIES A B

Transitional / Professional 22 mm 83 mmContemporary 25 mm 86 mm

E SERIES A B

Transitional / Professional 29 mm 89 mmProfessional (51 mm thick) 54 mm 114 mmContemporary 35 mm 95 mm

INTEGRATED DRAWER FRONT

CUSTOM PANEL W H D

Typical Dimensions 759 mm 264 mm 19 mmMin Thickness 16 mm

Page 44: DESIGN GUIDE - Sub-Zero

44 | English

WARMING DRAWERS

Planning Information

The warming drawer must be installed with a Wolf drawer front, avail able through an authorized Wolf dealer. Specific installation instructions are included with the drawer front.

The warming drawer can be installed in a standard or flush inset application.

For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 5 mm so the collar is flush with the cabinet face frame but the drawer front will sit proud. A flush inset installation requires the drawer collar and front panel be recessed to be flush with sur-rounding cabinetry. Refer to the illustrations on the following pages for minimum cabinet dimensions for your specific installation.

Finish the edges of the opening. They may be visible when the drawer is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Warming Drawer 90 kg

TRIM OVERLAP

Top, Bottom and Sides 16 mm

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the warming drawer can be placed in an adjacent cabinet within reach of the power cord.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50/60 Hz

Service 850 W

Receptacle grounding-type (earthed)

Power Cord .9 m

Page 45: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 45

WARMING DRAWERS

Warming Drawer

STANDARD INSTALLATION

FRONT VIEWSIDE VIEW

TOP VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

584 mmOPENING

DEPTH

E

727 mmOPENING WIDTH

232 mmOPENINGHEIGHT

ANTI-TIP BLOCK

Page 46: DESIGN GUIDE - Sub-Zero

46 | English

Warming Drawer

FLUSH INSET INSTALLATION

FRONT VIEWSIDE VIEW

TOP VIEW

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.

NOTE: Location of electrical supply within opening may require additional cabinet depth.

610 mmFLUSH INSET

DEPTH

ADRAWERFRONTDEPTH

270 mmFLUSH INSET

HEIGHT**

765 mmFLUSH INSET WIDTH**

19 mm

19 mm

19 mm E

E

FINISHEDCLEATS*

ANTI-TIP BLOCK

WARMING DRAWERS

DRAWER FRONT DEPTH (A) M SERIES E SERIES

Transitional / Professional 22 mm 29 mm

Professional (51 mm thick) NA 54 mm

Contemporary 25 mm 35 mm

Custom front panel depth is dependent on panel thickness.

Page 47: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 47

INDUCTION COOKTOPS

Induction Cooktops

Almost instantaneous temperature response. Practically no wasted heat. Induction cooking has been popular among European chefs and homeowners for decades. Now Wolf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. Electro-magnetic elements cause iron and magnetic stainless cook-ware to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan. The cooktop’s surface remains cool. Your kitchen stays cooler too. Transitional models have a brushed stainless steel trim. Contemporary models can be mounted flush with the countertop.

The following models have the same stainless steel frame as our module cooktops for paired installations: ICBCI243TF/S, ICBCI304TF/S, and ICBCI365TF/S.

ICBCI365C/B

ICBCI365TF/S

ICBCI304C/B

ICBCI243TF/S

INDUCTION COOKTOPS

TRANSITIONAL

CONTEMPORARY

ICBCI243C/B

ICBCI304TF/S

Page 48: DESIGN GUIDE - Sub-Zero

48 | English

Induction Cooktops

60 cm TRANSITIONAL

INDUCTION COOKTOPS

914 mm

533mm

64 mmCONDUIT

32 mm22mm

91 cm CONTEMPORARY

762 mm

533mm

64 mmCONDUIT

32 mm22mm

76 cm CONTEMPORARY

51 mmCONDUIT

32 mm22mm

600 mm

533mm

600 mm

533mm

64 mmCONDUIT

32 mm22mm

60 cm CONTEMPORARY

91 cm TRANSITIONAL

914 mm

533mm

51 mmCONDUIT

32 mm22mm

762 mm

533mm

51 mmCONDUIT

32 mm22mm

76 cm TRANSITIONAL

Page 49: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 49

INDUCTION COOKTOPS

Planning Information

A minimum height clearance of 159 mm is required from the top of the countertop to any combustible surface directly below the cooktop.

Contemporary induction cooktops can be mounted flush with the top of the countertop, or as a frameless standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cutout must be provided.

IMPORTANT NOTE: Flush mount installations are intended for granite, solid surface, or stone countertop surfaces only.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required.

Performance may be compromised if the electrical supply is less than 220 volts.

The cooktop is supplied with a single phase and 3-phase convertible power inlet box.

ELECTRICAL REQUIREMENTS

INDUCTION COOKTOPS SINGLE PHASE 3-PHASE

Required Power Supply 220-240 V AC 50/60 Hz

380-415 V AC 50 Hz

TOTAL AMPS SINGLE PHASE 3-PHASE

60 cm Induction 30 1676 cm Induction 32 1691 cm Induction 48 16

Induction Cooktops

ELEMENT RATING

60 cm COOKTOP W

279 mm 2600 / 3150 boost203 mm 2100 / 3000 boost203 mm 2100

76 cm COOKTOP W

279 mm 2600 / 3150 boost203 mm 2100 / 3000 boost203 mm 2100152 mm 1400

91 cm COOKTOP W

279 mm 2600 / 3700 boost(2) 203 mm 2100 / 3000 boost(2) 203 mm 2100

Page 50: DESIGN GUIDE - Sub-Zero

50 | English

INDUCTION COOKTOPS

E

COUNTERTOP CUTOUT

254 mm

114 mm

89 mm

FRONT VIEWSIDE VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical supply location only applies to installations with built-in oven.

762mm

330mm

457mm

51mm

WWIDTH

495mm

64 mm

64 mm

914 mm minFLOOR TO

COUNTERTOP

CUTOUT WIDTH W

60 cm Cooktop 562 mm

76 cm Cooktop 737 mm

91 cm Cooktop 889 mm

60 cm / 76 cm / 91 cm Induction Cooktop

STANDARD INSTALLATION

Page 51: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 51

INDUCTION COOKTOPS

60 cm / 76 cm / 91 cm Induction Cooktop

FLUSH INSTALLATION

E

ARECESS

537 mmRECESS

40 mm min

WCUTOUT WIDTH

COUNTERTOP CUTOUT

495mm

64 mm

64 mm

254 mm

114 mm

89 mm

FRONT VIEWSIDE VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical supply location only applies to installations with built-in oven.Outside corner radius 11 mm.

762mm

330mm

457mm

51mm

8 mm

22mm MAX

COUNTERTOPPROFILE

914 mm minFLOOR TO

COUNTERTOP

CUTOUT WIDTH W A

60 cm Cooktop 562 mm 603 mm

76 cm Cooktop 737 mm 765 mm

91 cm Cooktop 889 mm 918 mm

Page 52: DESIGN GUIDE - Sub-Zero

52 | English

Gas Cooktops

Like their oven counterparts, the new generation of Wolf gas cooktops features two new looks—transitional and profes-sional. New performance enhancements make delicious results even more of a certainty than ever. Multiple sizes, choice of knob colors, and distinctly different grates—the new gas cooktops offer exceptional design flexibility.

GAS COOKTOPS

ICBCG365P/S

ICBCG304P/S

ICBCG365T/S

ICBCG304T/S

GAS COOKTOPS

TRANSITIONAL

PROFESSIONAL

Page 53: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 53

762 mm

533mm

22mm

102 mm

Gas Cooktops

76 cm TRANSITIONAL

914 mm

533mm

22mm

102 mm

91 cm TRANSITIONAL

762 mm

533mm

22 mm

102 mm

76 cm PROFESSIONAL

914 mm

22 mm

102 mm

533mm

91 cm PROFESSIONAL

BURNER RATING

76 cm COOKTOP kW

Large 5.3Medium 3.5(2) Small 2.7

91 cm COOKTOP kW

Large 5.3Medium 3.5(3) Small 2.7

GAS COOKTOPS

Page 54: DESIGN GUIDE - Sub-Zero

54 | English

GAS COOKTOPS

Planning Information

A minimum 51 mm is required from the bottom of the cooktop to combustible materials. If a cooktop is installed above an oven, a minimum of 6 mm is required between the units.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustration on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50/60 Hz

Service 0.2 A

Receptacle grounding-type (earthed)

Power Cord 1.8 m

GAS SUPPLY

Installation must conform with all applicable gas codes.

A gas supply line of 19 mm rigid pipe must be provided to the cooktop. If local codes permit, a certified, .9 m long, 13 mm or 19 mm ID flexible metal appliance connector is recommended to connect the units 1/2" NPT (or ISO 7/1-14) male inlet to the gas supply line.

The gas cooktops contain a regulator for natural gas and LP gas.

Wolf natural gas cooktops will function up to 3124 m in alti-tude without adjustment and LP gas cooktops will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conver-sion kit.

GAS REQUIREMENTS

NATURAL GAS WC

Supply Pressure 12.5 mbar

LP GAS WC

Supply Pressure 25 mbar

Page 55: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 55

GAS COOKTOPS

76 cm / 91 cm Cooktop

STANDARD INSTALLATION

254 mm

102 mm

89 mm

FRONT VIEWSIDE VIEW

COUNTERTOP CUTOUT

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical and gas supply location only applies to installations with built-in oven.

762mm

WWIDTH

330mm

457mm

229mm

495mm

64 mm

64 mm

E G

CUTOUT WIDTH W

76 cm Cooktop 737 mm

91 cm Cooktop 889 mm

Page 56: DESIGN GUIDE - Sub-Zero

56 | English

MODULE COOKTOPS

Module Cooktops

Wolf 38 cm modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates, and trim allow them to integrate perfectly with their larger coun-terparts and deliver equal performance. Combine modules à la carte-style to create a custom cooktop, or add specialty functions alongside an existing cooktop.

Full-size cooktops including ICBCI243TF/S, ICBCI304TF/S, and ICBCI365TF/S feature the same brushed stainless frame, making them ideal for pairing with modules.

MODULE COOKTOPS

ICBSM15TF/S STEAMER

ICBCI152TF/S INDUCTION

ICBCG152TF/S GAS

ICBTM15TF/S TEPPANYAKI

ICBGM15TF/S GRILL

ICBMM15TF/S MULTIFUNCTION

Page 57: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 57

MODULE COOKTOPS

22 mm

127 mm

381mm

533mm

381mm

533mm

22 mm

51 mm

381mm

533mm

222mm

22mm

102mm

DRAINOUTLET

Module Cooktops

INDUCTION GRILL TEPPANYAKI

381mm

533mm

22mm

127mm

32mm

MULTIFUNCTION

381 mm

533mm

32mm

CONDUIT

22mm

51 mm

381mm

533mm

22 mm

102 mm

GAS

STEAMER

Page 58: DESIGN GUIDE - Sub-Zero

58 | English

MODULE COOKTOPS

Planning Information

IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the steamer or grill modules.

A minimum 51 mm is required from the bottom of the module to combustible materials. For the teppanyaki module, a minimum 22 mm is required from the bottom of the unit to any material.

Refer to the illustrations on the following pages for installa-tion of modules.

MULTIPLE COOKTOPS

When multiple modules are installed side by side, refer to the chart and illustration below for typical configurations. The cutout dimensions provided will accommodate the use of an optional filler strip if desired.

COUNTERTOP CUTOUT W

(2) 38 cm Modules* 737 mm

(3) 38 cm Modules* 1118 mm

(4) 38 cm Modules* 1505 mm

(5) 38 cm Modules* 1886 mm

(6) 38 cm Modules* 2267 mm

60 cm Cooktop / 38 cm Module* 956 mm

76 cm Cooktop / 38 cm Module* 1118 mm

76 cm Cooktop / (2) 38 cm Module* 1473 mm

91 cm Cooktop / 38 cm Module* 1270 mm

*Dimensions apply to ICBCI152TF/S, ICBCE152TF/S, ICBCG152TF/S, ICBSM15TF/S, ICBGM15TF/S, ICBTM15TF/S and ICBMM15TF/S.

64 mmMIN

495 mmCUTOUTDEPTH

WCUTOUT WIDTH

FRONT OF COUNTERTOP

64 mmMIN

Countertop cutout

Page 59: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 59

MODULE COOKTOPS

Planning Information

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required.

The induction cooktop is supplied with a single phase and 3-phase convertible power inlet box.

When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply.

ELECTRICAL REQUIREMENTS

INDUCTION MODULE

Single Phase 220-240 VAC, 50/60 Hz3-Phase 380-415 V AC 50 HzTotal Amps 16

ELECTRIC MODULES

Electrical Supply 220-240 VAC, 50/60 HzSteamer, Teppanyaki 2700 WGrill 2800 W

GAS MODULES

Electrical Supply 220-240 VAC; 50/60 HzService 0.2 AReceptacle grounding-type (earthed)Power Cord 1.8 m

DRAIN OUTLET

The steamer module requires a method for draining hot water. Options include connecting a drain hose from the 16 mm outlet tied into an existing drain, a separate drain with freefall, or placing a heat-resistant receptacle under the drain outlet.

GAS SUPPLY

Installation must conform with all applicable gas codes.

For gas modules, a gas supply line of 19 mm rigid pipe must be provided to the module. If local codes permit, a certi-fied, .9 m long, 13 mm or 19 mm ID flexible metal appliance connector is recommended to connect the units 1/2" NPT (or ISO 7/1-14) male inlet to the gas supply line.

When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.

Wolf natural gas cooktops will function up to 3124 m in alti-tude without adjustment and LP gas cooktops will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conver-sion kit.

GAS REQUIREMENTS

NATURAL GAS WC

Supply Pressure 25 mbar

LP GAS WC

Supply Pressure 37 mbar

Page 60: DESIGN GUIDE - Sub-Zero

60 | English

Induction Module

STANDARD INSTALLATION

356mm

495mm

64 mm

64 mm

FRONT VIEWSIDE VIEW

COUNTERTOP CUTOUT

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.

330mm

457mm

E

762mm

51mm

914 mm minFLOOR TO

COUNTERTOP

MODULE COOKTOPS

Page 61: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 61

Steamer Module

STANDARD INSTALLATION

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.

FRONT VIEWSIDE VIEW

COUNTERTOP CUTOUT

330mm

457mm

E

762mm

200mm

152mm314

mm

DRAINOUTLET

495mm

64 mm MIN

64 mm MIN

356mm

178mm

MODULE COOKTOPS

Page 62: DESIGN GUIDE - Sub-Zero

62 | English

MODULE COOKTOPS

Grill / Teppanyaki Module

STANDARD INSTALLATION

495mm

64 mm MIN

64 mm MIN

FRONT VIEWSIDE VIEW

COUNTERTOP CUTOUT

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.

330mm

457mm

178mm

762mm

E

356mm

Page 63: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 63

Gas / Multifunction Module

STANDARD INSTALLATION

MODULE COOKTOPS

FRONT VIEWSIDE VIEW

COUNTERTOP CUTOUT

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.

330mm

457mm

E G

762mm

356mm

495mm

64 mm MIN

64 mm MIN

178mm

Page 64: DESIGN GUIDE - Sub-Zero

64 | English

COFFEE SYSTEMS

Coffee Systems

Make professional-quality coffee, espresso, cappuccino, latte, and more. The Wolf coffee system automatically steams and foams the milk perfectly. The water temperature and brew strength are adjustable. It uses either whole-bean or ground coffee. The design pairs beautifully, either side-by-side or in a tower application, with other Wolf products such as the convection steam oven. Coffee systems can be installed in a standard or flush inset application. All 76 cm trim options are based on model ICBEC24/B.

COFFEE SYSTEMS

60 cm MODELS

76 cm E SERIES TRIM

76 cm M SERIES TRIM

TRANSITIONAL

ICBEC24/S

PROFESSIONAL

CONTEMPORARY

76 cm E SERIES TRIM

76 cm M SERIES TRIM

76 cm M / E SERIES TRIM

ICBEC24/B

Page 65: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 65

COFFEE SYSTEMS

454mm

22 mm

UNITFULL EXTENSION

464mm

WWIDTH

457 mmBEHIND FRAME

WIDTH W

60 cm Model 597 mm

76 cm Trim 759 mm

Coffee System

DIMENSIONS

Page 66: DESIGN GUIDE - Sub-Zero

66 | English

COFFEE SYSTEMS

Planning Information

The coffee system can be installed in a standard or flush inset application. All 76 cm trim options are based on model ICBEC24/B. The sides of the cabinetry opening must be adequate to support installation of the mounting slides. Refer to the illustration below.

Finish the edges of the opening. They may be visible when the unit is slid forward.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Coffee System 45 kg

TRIM OVERLAP 60 cm MODEL 76 cm TRIM

Top 5 mm 5 mmBottom 0 mm 0 mmSides 18 mm 98 mm

COMBINATION INSTALLATION

To install a coffee system above a cup warming drawer, one opening for both units must be specified. To achieve the minimum reveal between units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50/60 Hz

Service 1350 W

Receptacle grounding-type (earthed)

Power Cord 1.8 m

356mm

254mm

19 mmTYPICAL

Side support

Page 67: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 67

SLIDESUPPORT

FRONT VIEWSIDE VIEW

TOP VIEW

E449 mmOPENINGHEIGHT

WOPENING WIDTH

SLIDESUPPORT

NOTE: 60 cm model and model with 76 cm trim require the same opening dimensions.

457 mmOPENING

DEPTH

Coffee System

STANDARD INSTALLATION

OPENING WIDTH W

60 cm Model 562 mm

76 cm Trim 562 mm

COFFEE SYSTEMS

Page 68: DESIGN GUIDE - Sub-Zero

68 | English

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

WFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

FINISHEDCLEATS*

482 mmFLUSHINSET

DEPTH***25 mm

460 mm FLUSH INSET

HEIGHT**

8 mm

3 mm

A

TOP VIEW

E

SLIDESUPPORT

SLIDESUPPORT

Coffee System

FLUSH INSET INSTALLATION

FLUSH INSET WIDTH W A

60 cm Model 603 mm 21 mm

76 cm Trim 765 mm 102 mm

COFFEE SYSTEMS

Page 69: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 69

Cup Warming Drawers

Wolf cup warming drawers preheat cups so hot beverages stay hot longer. The temperature is adjustable. Two model options match the look of Wolf stainless and black coffee systems. Cup warming drawers can be installed in a stan-dard or flush inset application.

CUP WARMING DRAWERS

CUP WARMING DRAWER

533 mmBEHIND FRAME

140mm

22mm

DRAWERFULL EXTENSION

483mm

597 mm

DIMENSIONS

ICBCW24/B BLACK

ICBCW24/S STAINLESS

Page 70: DESIGN GUIDE - Sub-Zero

70 | English

CUP WARMING DRAWER

Planning Information

The cup warming drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

An anti-tip block must be installed to prevent the cup warming drawer from tipping forward when opened.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Cup Warming Drawer 34 kg

TRIM OVERLAP

Top 0 mmBottom 0 mmSides 18 mm

COMBINATION INSTALLATION

To install a cup warming drawer below a coffee system, one opening for both units must be specified. To achieve the minimum reveal between units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal.

Installation of an anti-tip block is not necessary when the cup warming drawer is installed below a coffee system.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50/60 Hz

Service 550 W

Receptacle grounding-type (earthed)

Power Cord .9 m

Page 71: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 71

Cup Warming Drawer

STANDARD INSTALLATION

FRONT VIEWSIDE VIEW

TOP VIEW

140 mmOPENING HEIGHT

533 mmOPENING

DEPTH

E

562 mmOPENING WIDTH

ANTI-TIP BLOCK

CUP WARMING DRAWER

Page 72: DESIGN GUIDE - Sub-Zero

72 | English

Cup Warming Drawer

FLUSH INSET INSTALLATION

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

FRONT VIEWSIDE VIEW

FINISHEDCLEATS*

558 mmFLUSHINSET

DEPTH***25 mm

3 mm

3 mm

TOP VIEW

146 mm FLUSH INSET HEIGHT**

21mm E

603 mmFLUSH INSET WIDTH**

ANTI-TIP BLOCK

CUP WARMING DRAWER

Page 73: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 73

Vacuum Seal Drawer

The vacuum seal drawer can be installed in a standard or flush inset application. Stainless steel, black glass, and integrated drawer fronts are available in 61 cm and 76 cm widths. The integrated drawer front allows for a custom panel.

DRAWER FRONTS

VACUUM SEAL DRAWER

INTEGRATED

BLACK GLASS

STAINLESS STEEL

533 mmBEHIND FRAME

140mm

DRAWERFULL

EXTENSION

432mm

597 mm 22mm

DIMENSIONS

DRAWER FRONT W

61 cm Drawer Front 597 mm

76 cm Drawer Front 759 mm

140mm

W

DRAWER FRONT DIMENSIONS

Page 74: DESIGN GUIDE - Sub-Zero

74 | English

VACUUM SEAL DRAWER

Planning Information

The vacuum seal drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open.

For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 3 mm reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Vacuum Seal Drawer 34 kg

TRIM OVERLAP

Top 0 mmBottom 0 mmSides 18 mm

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply 220–240 V AC, 50/60 Hz

Service 320 W

Receptacle grounding-type (earthed)

Power Cord .9 m

Page 75: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 75

Vacuum Seal Drawer

STANDARD INSTALLATION

FRONT VIEWSIDE VIEW

TOP VIEW

141 mmOPENING HEIGHT

E

562 mmOPENING WIDTH

ANTI-TIP BLOCK

533 mmOPENING

DEPTH

VACUUM SEAL DRAWER

Page 76: DESIGN GUIDE - Sub-Zero

76 | English

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.***Does not include additional depth for the electrical connection.

FRONT VIEWSIDE VIEW

22 mm

2 mm

3 mm

TOP VIEW

146 mm FLUSH INSET HEIGHT**

E

ANTI-TIP BLOCK

FINISHEDCLEATS*

WFLUSH INSET WIDTH**

A

558 mmFLUSHINSET

DEPTH***

Vacuum Seal Drawer

FLUSH INSET INSTALLATION

FLUSH INSET WIDTH W A

610 mm Opening 603 mm 21 mm

762 mm Opening 765 mm 102 mm

VACUUM SEAL DRAWER

Page 77: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 77

Dual Fuel Ranges

Discover a new world of cooking—the best of two worlds, actually—with a Wolf dual fuel range. Topside, gas cooking in all its glory, with the fine control of dual-stacked, sealed burners and options that include the remarkable French top. Below, that marvel of culinary technology, the Wolf convec-tion electric oven. Its two fans and four heating elements let you select from 10 cooking modes so you can choose the one precisely suited to the dish you are preparing. The ovens are self-cleaning. With a variety of range widths to choose from, kitchens large and small become gateways to the exciting new world of dual fuel cooking. All models are constructed of stainless steel and can be ordered in natural or LP gas.

DUAL FUEL RANGES

CONFIGURATIONS

91 cm RANGE

ICBDF366

ICBDF364C

ICBDF364G

ICBDF304

76 cm RANGE

ICBDF606CG

ICBDF604CF

152 cm RANGE

ICBDF486C

ICBDF486G

ICBDF484CG

ICBDF484F

122 cm RANGE

Page 78: DESIGN GUIDE - Sub-Zero

78 | English

Dual Fuel Ranges

76 cm RANGE 91 cm RANGE

DUAL FUEL RANGES

122 cm RANGE

1527 mm

235mm

937 mm*

1165 mm

1419 mm

1038 mm

1194 mm

664 mm

635 mm

613 mm

699 mm

749 mm

*929 mm MIN TO 983 mm MAX.

911mm

929 mm*

152 cm RANGE

759 mm

235mm

937 mm*

1165 mm

1419 mm

1038 mm

1194 mm

664 mm

635 mm

613 mm

699 mm

749 mm

*929 mm MIN TO 983 mm MAX.

911mm

929 mm*

911 mm

235mm

937 mm*

1165 mm

1419 mm

1038 mm

1194 mm

664 mm

635 mm

613 mm

699 mm

749 mm

*929 mm MIN TO 983 mm MAX.

911mm

929 mm*

1216 mm

235mm

937 mm*

1165 mm

1419 mm

1038 mm

47" (1194)

664 mm

635 mm

613 mm

699 mm

749 mm

*929 mm MIN TO 983 mm MAX.

911mm

929 mm*

SIDE VIEW—ALL RANGES

Page 79: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 79

DUAL FUEL RANGES

Dual Fuel Ranges

BURNER RATING

SURFACE BURNER SIM HI

Large .3 kW 4.8 kW

Small .1 kW 2.7 kW

FEATURE NATURAL LP

Charbroiler 5.6 kW 5.2 kW

Griddle 5.6 kW 5.2 kW

French Top 4.8 kW 4.0 kW

Page 80: DESIGN GUIDE - Sub-Zero

80 | English

Planning Information

When installing against a combustible surface, a minimum 254 mm riser is required for a 91 cm dual fuel range with charbroiler or griddle and all 122 cm and 152 cm models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.

A Wolf pro ventilation hood is recommended with the dual fuel range. Refer to page 113 for Pro Ventilation.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the fol-lowing page. A separate circuit servicing only this appliance is required.

Wolf dual fuel ranges have a terminal block that allows for a 3-wire or 4-wire installation.

Performance may be compromised if the electrical supply is less than 220 volts.

The range is supplied with a single phase and 3-phase convertible power inlet box. The wiring diagram covering the control circuit is provided with the oven.

REQUIRED POWER SUPPLY

Single phase 220-240 V AC, 50/60 Hz

3phase 380-415 V AC, 50 Hz

MAXIMUM CONNECTED LOAD

DUAL FUEL RANGES SINGLE PHASE 3PHASE

762 mm and 914 mm 19 amps 18 amps1219 mm 35 amps 18 amps1524 mm 38 amps 18 amps

GAS SUPPLY

Installation must conform with all applicable gas codes.

A gas supply line of 19 mm rigid pipe must be provided to the range. If local codes permit, a certified, .9 m long, 13 mm or 19 mm ID flexible metal appliance connector is recommended to connect the units ISO 7/1-14 female inlet to the gas supply line.

Wolf natural gas ranges will function up to 3124 m in altitude without adjustment and LP gas ranges will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.

GAS REQUIREMENTS

NATURAL GAS WC

Supply Pressure 25 mbar

LP GAS WC

Supply Pressure 37 mbar

DUAL FUEL RANGES

Page 81: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 81

DUAL FUEL RANGES

Dual Fuel Range

INSTALLATION

FRONT VIEWSIDE VIEW

*Without ventilation hood, 914 mm minimum clearance countertop to combustible materials, 1118 mm for charbroiler.

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.For island installation, 305 mm minimum clearance back of range to combustible rear wall above countertop.

330mm

457mm

152mm

57mm

LOCATION OF GAS AND ELECTRICAL EXTENDS

ON FLOORA

83 mm

254 mmGAS

330 mmELECTRICAL

937 mmTO COOKING

SURFACE

WOPENING WIDTH

762 mm TO 914 mmTO BOTTOM OF

VENTILATION HOOD*

G E

OPENING WIDTH W A

76 cm Model 762 mm 216 mm

91 cm Model 914 mm 343 mm

122 cm Model 1219 mm 610 mm

152 cm Model 1530 mm 787 mm

Page 82: DESIGN GUIDE - Sub-Zero

82 | English

SEALED BURNER RANGETOPS

Sealed Burner Rangetops

Wolf sealed burner rangetops incorporate all the gas cooking features of a Wolf dual fuel range. Customize your rangetop with your preferred combination of burners (from four to six), infrared griddle or charbroiler, or the remarkable French top. Compared with conventional electric elements, the infrared elements of the charbroiler and griddle are a revelation. They preheat almost instantly, distribute heat more evenly, and deliver fast temperature recovery after food is placed on the surface. All sealed burner rangetop models are constructed of stainless steel and can be ordered in natural or LP gas.

CONFIGURATIONS

ICBSRT486C

ICBSRT364C

ICBSRT486G

ICBSRT364G

ICBSRT484CG

ICBSRT484F

91 cm RANGETOP76 cm RANGETOP 122 cm RANGETOP

ICBSRT304

Page 83: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 83

1216 mm

235mm 445 mm

699 mm

318 mm

664 mm

724 mm

208mm

191mm 613 mm 216

mm

Sealed Burner Rangetops

76 cm RANGETOP

122 cm RANGETOP

SIDE VIEW—ALL RANGETOPS

SEALED BURNER RANGETOPS

759 mm

235mm 445 mm

699 mm

318 mm

664 mm

724 mm

208mm

191mm 613 mm 216

mm

91 cm RANGETOP

911 mm

235mm 445 mm

699 mm

318 mm

664 mm

724 mm

208mm

191mm 613 mm 216

mm

BURNER RATING

SURFACE BURNER SIM HI

Large .9 kW 4.6 kWSmall .6 kW 2.8 kW

FEATURE NATURAL LP

Charbroiler 5.8 kW 5.3 kWGriddle 5.5 kW 4.7 kWFrench Top 4.6 kW 4.0 kW

Page 84: DESIGN GUIDE - Sub-Zero

84 | English

SEALED BURNER RANGETOPS

Planning Information

The platform to support the sealed burner rangetop must include a cutout for electrical and gas supply connections. Refer to the chart below for minimum base support.

When installing against a combustible surface, a minimum 254 mm riser is required for 91 cm and 122 cm sealed burner rangetops with a charbroiler or griddle. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.

A Wolf pro ventilation hood is recommended with the sealed burner rangetop. Refer to page 113 for Pro Ventilation.

A downdraft can be used with model ICBSRT304. An acces-sory trim kit is necessary for this installation. Contact an authorized Wolf dealer for details.

INSTALLATION REQUIREMENTS

PLATFORM

Thickness 19 mm

BASE SUPPORT MIN

76 cm Rangetop 91 kg91 cm Rangetop 113 kg122 cm Rangetop 136 kg

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 220-240 VAC; 50/60 Hz

Service 0.2 A

Receptacle grounding-type (earthed)

Power Cord 2 m

GAS SUPPLY

Installation must conform with all applicable gas codes.

A gas supply line of 19 mm rigid pipe must be provided to the rangetop. If local codes permit, a certified, .9 m long, 13 mm or 19 mm ID flexible metal appliance connector is recommended to connect the units ISO 7/1-14 female inlet to the gas supply line.

Wolf natural gas rangetops will function up to 3124 m in altitude without adjustment and LP gas ranges will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conver-sion kit.

GAS REQUIREMENTS

NATURAL GAS WC

Supply Pressure 25 mbar

LP GAS WC

Supply Pressure 37 mbar

Page 85: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 85

FRONT VIEWSIDE VIEW

330mm

457mm

152mm

WOPENING WIDTH

610 mm MAXPLATFORM

762 mm TO 914 mmTO BOTTOM OF

VENTILATION HOOD*

191 mm OPENINGHEIGHT

PLATFORMPLATFORMTOP VIEW

406 mmELECTRICAL

AND GAS

102mm

E G

BACK WALL

*Without ventilation hood, 914 mm minimum clearance countertop to combustible materials, 1118 mm for charbroiler.

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical and gas supply located through bottom of platform.For island installation, 305 mm minimum clearance back of range to combustible rear wall above countertop.

Sealed Burner Rangetop

INSTALLATION

OPENING WIDTH W

76 cm Model 762 mm

91 cm Model 914 mm

122 cm Model 1219 mm

SEALED BURNER RANGETOPS

Page 86: DESIGN GUIDE - Sub-Zero

86 | English

Outdoor Grills and Modules

Taste what happens when the heritage of professional cooking moves from the kitchen to the patio. Like their indoor counterparts, Wolf outdoor grills are precision instruments. Constructed of heavy-duty stainless steel, the 76 cm, 91 cm, 107 cm, and 137 cm grills have powerful burners every five inches for even heat distribution. An electric rotisserie with infrared burner produces succulent poultry and roasts. All grill models can be built in and all except the 137 cm grill, can be used on a cart for portable convenience. The 25,000 Btu burner module can be built into an outdoor kitchen and the side burner attached to a cart. Wolf grills and modules can be ordered in natural or LP gas.

OUTDOOR GRILLS | MODULES

OUTDOOR GRILLS

ICBOG30

ICBOG42

ICBOG36

ICBOG54

ICBBM13 BURNER MODULE

ICBSB13 SIDE BURNER

OUTDOOR MODULES

Page 87: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 87

273 mm

762 mm

705 mm330mm

WWIDTH

MAX DOOR/DRAWER CLEARANCE 559 mm

610 mmTO GRILL

PLATFORM

927mm

705 mm

305mm

76 mm

762 mmHOOD CLOSED

318 mmTO

GRILLINGSURFACE

686mm

WWIDTH

705 mm

64mm

CLEARANCEFOR OPEN

HOOD

139mm

OUTDOOR GRILLS | MODULES

Outdoor Grills and Modules

OUTDOOR GRILL

GRILL CART

BURNER MODULE / SIDE BURNER OUTDOOR GRILL W

ICBOG30 762 mm

ICBOG36 914 mm

ICBOG42 1067 mm

ICBOG54 1372 mm

GRILL CART W

ICBCART30 762 mm

ICBCART36 914 mm

ICBCART42 1067 mm

Page 88: DESIGN GUIDE - Sub-Zero

88 | English

OUTDOOR GRILLS | MODULES

Outdoor Grills and Modules

BURNER RATING

GRILL BURNERS kW

ICBOG30, ICBOG36, ICBOG42, ICBBM13, ICBSB13 7.3ICBOG54 7.5

SEAR ZONE kW

ICBOG36, ICBOG42 7.3ICBOG54 7.5

ROTISSERIE kW

ICBOG30 4.1ICBOG36, ICBOG42 4.7ICBOG54 (2) 4.1

Planning Information

For portable applications, Wolf grill carts are designed specifically to fit grill models ICBOG30, ICBOG36, and ICBOG42 and the side burner. Model ICBOG54 is designed for built-in applications only.

For built-in applications, Wolf outdoor grills and the burner module are designed for easy placement into a built-in enclosure. For outdoor grills, installation in a combustible enclosure requires an insulating liner. For the burner module, an insulating liner is not required. The enclosure should be built according to specifications for your specific installa-tion on the following pages. If the burner module is installed next to an outdoor grill, a minimum of 305 mm is required between the units. A rotisserie side conversion kit is avail-able from an authorized Wolf dealer.

Optional stainless steel accessory doors and drawers are available for built-in applications. Refer to pages 92–96.

Grill carts, insulating liners, and stainless steel doors and drawers are avail able through an authorized Wolf dealer.

Page 89: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 89

OUTDOOR GRILLS | MODULES

Planning Information

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

The electrical outlet must be located within reach of the power cord. A separate circuit servicing only this appliance is required.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) or residual current device (RCD) is required to reduce the risk of electrical shock.

ELECTRICAL REQUIREMENTS (GRILL / MODULE)

Electrical Supply grounded, 220-240 VAC, 50/60 Hz

Service 1 A

Receptacle 3-prong grounding-type (earthed), IEC inlet

ELECTRICAL REQUIREMENTS (ROTISSERIE)

Electrical Supply—Input grounded, 220-240 VAC, 50/60 Hz

Electrical Supply—Output 12 VDC

Service 0.5 A (6 Watts)

Receptacle barrel plug, 2.1 mm ID x 5.5 mm OD

GAS SUPPLY

Installation must conform with all applicable gas codes.

A gas supply line of 19 mm rigid pipe must be provided to the outdoor grill or module. If local codes permit, a certified, .9 m long, 13 mm or 19 mm ID flexible metal appliance con-nector is recommended to connect the units ISO 7-1 female inlet to the gas supply line.

An inline regulator is installed on the unit for connecting to NAT or LP gas sources. For local dealer information, visit our website, wolfappliance.com.

If the outdoor grill is being connected to a whole house LP supply, the LP gas pressure regulator is not provided. It can be purchased from an authorized Wolf dealer.

GAS REQUIREMENTS

NATURAL GAS

Supply Pressure 12.5 mbarMin Line Pressure 17.5 mbarMax Regulator Pressure 100 mbar

LP GAS

Supply Pressure 25 mbarMin Line Pressure 27.4 mbarMax Regulator Pressure 100 mbar

Page 90: DESIGN GUIDE - Sub-Zero

90 | English

OUTDOOR GRILLS | MODULES

298mm

OPENINGHEIGHT

616 mmOPENING

DEPTH

152mm

GRILLOVERLAP

FRONT VIEW

TOP VIEW

WOPENING WIDTH

64 mm

330mm

89mm

G

102 mm

152mm

G

NOTE: Shaded area above countertop indicates minimum clearance tocombustible surfaces, combustible materials cannot be located within this area.

GRILLOPENING

21mm

COUNTERTOP OVERHANG

321mm

OPENINGHEIGHT

660 mmOPENING

DEPTH

305mm

273mm

127mm

CL

CL

70 mmKNOCKOUT

LINEROPENING

21mm

COUNTERTOP OVERHANG

LINEROVERLAP

FRONT VIEW

TOP VIEW

WOPENING WIDTH

NOTE: Shaded area above countertop indicates minimum clearance tocombustible surfaces, combustible materials cannot be located within this area.

305 mm

G

NON-COMBUSTIBLE ENCLOSURE W

ICBOG30 724 mm

ICBOG36 876 mm

ICBOG42 1029 mm

ICBOG54 1334 mm

For installation of the accessory doors and drawers, refer to Outdoor Accessories on the following pages.

Outdoor Grill

NON-COMBUSTIBLE INSTALLATION COMBUSTIBLE INSTALLATION

COMBUSTIBLE ENCLOSURE W

ICBOG30 851 mm

ICBOG36 1003 mm

ICBOG42 1156 mm

ICBOG54 1461 mm

Page 91: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 91

OUTDOOR GRILLS | MODULES

254 mmOPENINGHEIGHT

616 mmOPENING

DEPTH

152mm

MODULEOPENING

14mm

COUNTERTOP OVERHANG

MODULEOVERLAP

FRONT VIEW

TOP VIEW

305 mmOPENING

NOTE: Shaded area above countertop indicates minimum clearance tocombustible surfaces, combustible materials cannot be located within this area.An insulating liner is not required.

G

203mm

178mm

G

76 mm

305 mm

Burner Module

INSTALLATION

Page 92: DESIGN GUIDE - Sub-Zero

92 | English

OUTDOOR ACCESSORIES

SINGLE

DOUBLE

SINGLE DRAWER

2- OR 3-DRAWER

DOOR/DRAWER

TALL DRY STORAGE

SHORT DRY STORAGE

PAPER TOWEL DRAWER

Outdoor Accessories

ACCESS DOORS

ACCESSORY DRAWERS AND DOORS

TRASH/RECYCLING DRAWER

Page 93: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 93

70 mm

B

A

527mm

476mm

Access Doors

DIMENSIONS

DOOR WIDTH A B

46 cm Single 457 mm 413 mm

76 cm Double 762 mm 718 mm

91 cm Double 914 mm 870 mm

107 cm Double 1067 mm 1022 mm

137 cm Double 1372 mm 1327 mm

OPENING WIDTH W

46 cm Single 419 mm

76 cm Double 724 mm

91 cm Double 876 mm

107 cm Double 1029 mm

137 cm Double 1334 mm

IMPORTANT NOTE: The opening dimensions provided are for a standard installation. For a flush installation, refer to the overall dimensions and adjust the opening dimensions accordingly.

WOPENING WIDTH

483 mmOPENINGHEIGHT

25 mm minGRILL OPENING

FRONT VIEW

89 mmFINISHEDRETURN

W

TOP VIEW

INSTALLATION

OUTDOOR ACCESSORIES

Page 94: DESIGN GUIDE - Sub-Zero

94 | English

457mm

70 mm

330 mm

305 mm

527mm

483mm

OUTDOOR ACCESSORIES

610mm

70 mm

241mm

762 mm

686 mm

289mm

Accessory Drawers and Doors

SINGLE DRAWER

203 mm

483mm

70 mm

457 mm

368 mm

254mm

PAPER TOWEL DRAWER

DRAWER / DOOR

457mm

70 mm

483mm

762 mm

724 mm

527mm

2- OR 3-DRAWER

Page 95: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 95

502mm

70 mm

610 mm

559 mm

864mm

813mm

OUTDOOR ACCESSORIES

TRASH / RECYCLE DRAWER

70 mm

457 mm

406 mm

660mm

610mm

D

DEPTH D

Single 495 mm

Double 572 mm

502mm

70 mm

914 mm

864 mm

527mm

476mm

SHORT DRY STORAGE

Accessory Drawers and Doors

TALL DRY STORAGE

Page 96: DESIGN GUIDE - Sub-Zero

96 | English

OUTDOOR ACCESSORIES

OPENING W H D

Single Drawer 692 mm 248 mm 616 mm

Paper Towel Drawer 375 mm 210 mm 489 mm

2- or 3-Drawer 311 mm 489 mm 464 mm

Drawer/Door 730 mm 489 mm 464 mm

Tall Dry Storage 565 mm 819 mm 508 mm

Short Dry Storage 870 mm 483 mm 508 mm

Single Trash/Recycle 413 mm 616 mm 502 mm

Double Trash/Recycle 413 mm 616 mm 578 mm

BASE SUPPORT MIN

2- or 3-Drawer 68 kg

Drawer/Door 68 kg

Dry Storage 136 kg

IMPORTANT NOTE: The opening dimensions provided are for a standard installation. For a flush installation, refer to the overall dimensions and adjust the opening dimensions accordingly.

DOPENING

DEPTH

FRONT VIEW

TOP VIEW

HOPENINGHEIGHT

25 mm min

89 mmFINISHEDRETURN

W

WOPENING WIDTH

Accessory Drawers and Doors

INSTALLATION

Page 97: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 97

COOKTOP HOODS

ICBVW30B WALL

ICBVW36B WALL

ICBVW45B WALL

ICBVI42B ISLAND

ICBVW30S WALL

ICBVW36S WALL

ICBVI42S ISLAND

ICBVW36G WALL

ICBVW45G WALL

ICBVI45G ISLAND

COOKTOP VENTILATION HOODS

BLACK

STAINLESS

GLASS

Cooktop Ventilation Hoods

The new generation of Wolf cooktop ventilation hoods feature three new looks—black, stainless, and glass. Brilliant LED lighting illuminates your cooking surface while powerful multi-speed blowers whisk away smoke and odors. The dishwasher-safe filters can be removed easily for cleaning. The wall-mount and island hoods are crafted of stainless steel.

Page 98: DESIGN GUIDE - Sub-Zero

98 | English

COOKTOP HOODS

WWIDTH

489 mm

298 mm

540mm

260 mm

740 mm TO

997 mm*

57 mm

*1248 mm to 1505 mm with accessory flue extension.

Cooktop Ventilation Hoods

WALL HOODS—BLACK

1067 mm 673 mm

349 mm

600mm

286 mm

591 mm TO

813 mm*

57 mm

*1175 mm to 1397 mm with accessory flue extension.

ISLAND HOOD—BLACK

WIDTH W

ICBVW30B 762 mm

ICBVW36B 914 mm

ICBVW45B 1143 mm

Page 99: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 99

COOKTOP HOODS

WWIDTH

559 mm

298 mm

540mm

152mm

260 mm

740 mm TO

997 mm*

*1248 mm to 1505 mm with accessory flue extension.

Cooktop Ventilation Hoods

WALL HOODS—STAINLESS

1067 mm 673 mm

349 mm

600mm

286 mm

152mm

591 mmTO

813 mm*

*1175 mm to 1397 mm with accessory flue extension.

ISLAND HOOD—STAINLESS

WIDTH W

ICBVW30S 762 mm

ICBVW36S 914 mm

Page 100: DESIGN GUIDE - Sub-Zero

100 | English

COOKTOP HOODS

WWIDTH

489 mm

298 mm

540mm

260 mm

740 mm TO

997 mm*

57 mm

*1248 mm to 1505 mm with accessory flue extension.

Cooktop Ventilation Hoods

WALL HOODS—GLASS

1143 mm 673 mm

349 mm

600mm

286 mm

591 mm TO

813 mm*

57 mm

*1175 mm to 1397 mm with accessory flue extension.

ISLAND HOOD—GLASS

WIDTH W

ICBVW36G 914 mm

ICBVW45G 1143 mm

Page 101: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 101

COOKTOP HOODS

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

For wall hoods, locate the electrical supply within the shaded area shown in the illustration below. For island hoods, locate the electrical supply on the ceiling inside the top of the hood. A separate circuit servicing only this appli-ance is recommended.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz

Service 1.9 A

Planning Information

Wolf cooktop ventilation hoods are recommended for use with Wolf induction, electric, and gas cooktops, and mod-ules. For ranges and rangetops, a Wolf pro ventilation hood is recommended.

These hoods have a telescopic chimney flue. A flue exten-sion is available through an authorized Wolf dealer.

Installation of the cooktop hood should be 762 mm to 914 mm from the bottom of the hood to the countertop.

Wall and island hoods require an internal or remote blower assembly, avail able through an authorized Wolf dealer. Refer to Ventilation Suggestions on pages 117–119. Cooktop hoods have a vertical discharge with 152 mm round duct.

Consult a qualified HVAC professional for specific installa-tion and ducting applications.

Electrical location for all wall hoods

E

457mm

762 mm TO 914 mm BOTTOM EDGE TO COUNTERTOP

Page 102: DESIGN GUIDE - Sub-Zero

102 | English

Ceiling-Mounted Hood

The new ceiling-mounted hood is our most contemporary ventilation offering, nearly disappearing into its surround-ings. It comes in two widths and is available in stainless steel. The hood ships with a remote control and can be operated using the remote control or the control panel. The control panel is recessed into the right side of the hood. The dishwasher-safe filters can be removed easily for cleaning.

DIMENSIONS

COOKTOP VENTILATION

DIMENSIONS W A

914 mm Hood 902 mm 841 mm

1219 mm Hood 1200 mm 1121 mm

2 mmW

127 mm

533 mm

A337mm

184mm

337mm

184 mm TO

324 mm

ICBVC48S

ICBVC36S

CEILING-MOUNTED HOODS

Page 103: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 103

RECIRCULATING INSTALLATION

The ceiling-mounted hood with internal blower can be installed in a recirculating application. The air discharge must be a minimum of 1016 mm from every side of the hood. Refer to the illustration below. The ductwork and vent cover are not provided. A recirculation kit, available through an authorized Wolf dealer, is required.

Planning Information

Installation of the ceiling-mounted hood should be 914 mm to 2134 mm from the bottom of the hood to the countertop.

The hood can be operated using the remote control or the control panel located on the right side of the hood.

The hood is shipped without a blower assembly. A 900 CMH internal blower is avail able through an authorized Wolf dealer. Refer to Ventilation Suggestions on pages 117–119.

The ceiling-mounted hood includes a 152 mm round discharge for the internal blower. The blower box can be rotated to discharge right, left, front, or rear.

Consult a qualified HVAC professional for specific installa-tion and ducting applications.

1016 mm

Recirculation application

COOKTOP VENTILATION

Page 104: DESIGN GUIDE - Sub-Zero

104 | English

Planning Information

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply within the shaded area shown in the illustration below. Allow a minimum 305 mm electrical cable for connection. A separate circuit servicing only this appliance is required.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz

Service 1.9 A

E

914 mm TO 2134 mm BOTTOM EDGE TO COUNTERTOP

Electrical location

Opening Dimensions

CEILING-MOUNTED HOOD

Refer to the chart and illustrations below for opening dimen-sions and typical framing. Framing must be able to support a minimum of 45 kg.

HOOD W

91 cm Hood 873 mm

122 cm Hood 1175 mm

314 mm MIN TO451 mm MAX

Support framing (typical)

W508mm

Opening dimensions

COOKTOP VENTILATION

Page 105: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 105

Under-Cabinet Hood Insert

The new under-cabinet hood insert mounts inside a cabinet. It comes in two widths and is available in stainless steel. The hood ships with a remote control and can be operated using the remote control or the control panel. The dishwasher-safe filters can be removed easily for cleaning.

UNDER-CABINET HOOD INSERT

ICBVU30S

ICBVU24S

COOKTOP VENTILATION

DIMENSIONS

WIDTH W

ICBVU24S 521 mm

ICBVU30S 702 mm

W13mm

349mm

299 mm

Page 106: DESIGN GUIDE - Sub-Zero

106 | English

COOKTOP VENTILATION

Planning Information

The under-cabinet hood insert should be installed 610 mm to 914 mm from the bottom of the hood to the countertop.

The hood can be operated using the remote control or the control panel located at the front of the hood bottom.

The hood requires a 900 CMH internal blower, available through an authorized Wolf dealer. For local dealer information, visit our website, wolfappliance.com. Refer to Ventilation Suggestions on pages 117–119. The hood includes a 152 mm round discharge for the internal blower.

Consult a qualified HVAC professional for specific installa-tion and ducting applications.

HORIZONTALDISCHARGE

DISCHARGEABOVE CABINET

Recirculation application

RECIRCULATION APPLICATION

The hood can be installed in a recirculation application. Refer to the illustration below. Ductwork is not provided.

Recirculating filters, available through an authorized Wolf dealer, are required.

Page 107: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 107

COOKTOP VENTILATION

Opening Dimensions

UNDER-CABINET HOOD INSERT

Refer to the chart and illustration below for opening dimen-sions. The cabinet must be able to support a minimum of 45 kg.

OPENING WIDTH W

ICBVU24S 495 mm

ICBVU30S 676 mm

Planning Information

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply above or in an adjacent cabinet within reach of the power cord. Refer to the illustration below. A separate circuit servicing only this appliance is required.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz

Service 1.9 A

Power Cord 1.2 m

EE

610 mm TO 914 mmBOTTOM EDGE TO

COUNTERTOP

Electrical location

W 260mm

Opening dimensions

Page 108: DESIGN GUIDE - Sub-Zero

108 | English

DOWNDRAFT SYSTEMS

Downdraft Ventilation

Constructed of heavy duty stainless steel, the Wolf down-draft rises from the countertop to whisk away odor and smoke into stainless steel, mesh filters and can be lowered beneath the countertop when not in use. Downdrafts inte-grate perfectly with Wolf induction cooktops, gas cooktops, and some modules. They can also be installed with certain sealed burner rangetops.

ICBDD45

ICBDD36

ICBDD30

DOWNDRAFTS

51 mm

356mm

730mm

WDOWNDRAFT WIDTH

ACHIMNEY WIDTH

172mm

254mm

330mm

330mm

381mm

64 mm

60 mm

NOTE: Shown with front mounted internal blower with 152 mm round discharge,dashed line represents rear mount.

Downdraft

DIMENSIONS

WIDTH W A

ICBDD30 762 mm 673 mm

ICBDD36 914 mm 826 mm

ICBDD45 1143 mm 978 mm

Page 109: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 109

Planning Information

Wolf downdrafts can be installed with most Wolf cooktops, but are not compatible with the grill and steamer modules. Downdrafts can be installed with the sealed burner ran-getop model ICBSRT304. An accessory trim kit is necessary for this installation. Contact an authorized Wolf dealer for details.

For installation with a Wolf cooktop, a minimum 638 mm deep flat countertop is required.

For installation with a sealed burner rangetop or 762 mm or 914 mm contemporary cooktop, an accessory trim kit is required. Contact an authorized Wolf dealer for details.

The remote-mounted control module must be located within 2.7 m of the downdraft assembly and a minimum 76 mm from the edge of the cooktop cutout.

BLOWERS

Internal and remote blowers are available through an authorized Wolf dealer. Refer to Ventilation Suggestions on pages 117–119.

Internal blowers include a 152 mm round discharge and can be front or rear mounted. It can be discharged in any direc-tion by rotating the blower box. Remote blowers include a 254 mm discharge and can be discharged from the front or rear.

Consult a qualified HVAC professional for specific installa-tion and ducting applications.

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Certain installations may require that the electrical supply be placed in an adjacent cabinet.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz

Service 1.9 A

Receptacle grounding-type (earthed)

Power Cord .8 m

DOWNDRAFT SYSTEMS

Page 110: DESIGN GUIDE - Sub-Zero

110 | English

DOWNDRAFT SYSTEMS

E

FRONT VIEWSIDE VIEW

*152 mm back from countertop cutout when internal blower is rear mounted.

NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge.Centerline indicates center of downdraft cutout.

540mm

540mm

210 mm*

COOKTOP CUTOUT

68 mm

TOP VIEW

594mm

210 mm*

WDOWNDRAFT

CUTOUT WIDTH

E

Downdraft

INSTALLATION WITH STANDARD INSTALLED COOKTOP

CUTOUT WIDTH W

ICBDD30 699 mm

ICBDD36 851 mm

ICBDD45 1003 mm

Page 111: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 111

DOWNDRAFT SYSTEMS

E

FRONT VIEWSIDE VIEW

*152 mm back from countertop cutout when internal blower is rear mounted.

NOTE: Internal blower 152 mm round, side, rear, or bottom discharge. In-line and remote blower 254 mm round, rear discharge.Centerline indicates center of downdraft cutout.

540mm

540mm

210mm*

594mm

210 mm*

WDOWNDRAFT

CUTOUT WIDTH

E

COOKTOP CUTOUT

TOP VIEW

59 mm

Downdraft

INSTALLATION WITH FLUSH INSTALLED COOKTOP

CUTOUT WIDTH W

ICBDD30 699 mm

ICBDD36 851 mm

Page 112: DESIGN GUIDE - Sub-Zero

112 | English

FRONT VIEWSIDE VIEW

483 mmPLATFORM DEPTH

FRONT VIEWSIDE VIEW

*152 mm back from countertop cutout when internal blower is rear mounted.

NOTE: Internal blower 152 mm round, side, rear or bottom discharge. Remote blower 254 mm round, rear discharge.Centerline indicates center of downdraft cutout.

540mm

210 mm*

TOP VIEW

WDOWNDRAFT

CUTOUT WIDTH

210 mm*

540mm

594mm

RANGETOP OPENING

68 mm E

E

DOWNDRAFT SYSTEMS

Downdraft

INSTALLATION WITH SEALED BURNER RANGETOP

CUTOUT WIDTH W

ICBDD30 699 mm

ICBDD36 851 mm

Page 113: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 113

PRO VENTILATION

Pro Ventilation Hoods

Professional heritage shines through in Wolf professional-style ventilation. Exteriors are heavy-duty, welded stainless steel, so finely hand-finished that they appear seamless. Pro wall hoods are available in a variety of widths. Stainless steel baffle filters and halogen lighting extend the profes-sional look and back it up with pro-level performance. All pro ventilation hoods are crafted of stainless steel.

61 cm / 69 cm DEEP

PRO HOODS

WALL HOODS

Page 114: DESIGN GUIDE - Sub-Zero

114 | English

Pro Hoods

69 cm DEEP WALL HOOD

61 cm DEEP WALL HOOD

686 mm

305mm

102 mm

457mm

WWIDTH

PRO VENTILATION

WIDTH

61 cm DEEP WALL HOOD W

91 cm, 122 cm

69 cm DEEP WALL HOOD W

76 cm, 91 cm, 107 cm, 122 cm, 152 cm

102 mm

610 mm

305mm

457mm

WWIDTH

Page 115: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 115

Planning Information

Pro ventilation hoods are recommended for use with all Wolf cooking appliances. Wall hoods should be at least as wide as the cooking surface.

For optimal performance in wall hood applications, a pro 69 cm deep wall hood is recommended for use with ranges and rangetops with a charbroiler or griddle.

Installation of the hood should be 762 mm to 914 mm from the bottom of the hood to the countertop.

Pro hoods are shipped without a blower assembly. Internal and remote blowers are available through an authorized Wolf dealer. The blower will vary in size and is dictated by the cooking unit, volume of air, and length of the duct run. Refer to Ventilation Suggestions on pages 117–119.

Pro hoods accommodate a 254 mm round duct and have a vertical discharge. For the 61 cm and 69 cm deep wall hoods, a horizontal discharge kit is available through an authorized Wolf dealer.

Consult a qualified HVAC professional for specific installa-tion and ducting applications.

Optional stainless steel duct covers in a variety of heights are available for pro wall hoods through an authorized Wolf dealer.

PRO VENTILATION

ELECTRICAL REQUIREMENTS

Installation must comply with all applicable electrical codes and be properly grounded (earthed).

Locate the electrical supply within the shaded area shown in the illustration on the following page. Allow a minimum 305 mm electrical cable for connection. A separate circuit servicing only this appliance is required.

ELECTRICAL REQUIREMENTS

Electrical Supply 220-240 V AC, 50 Hz 220 V AC, 60 Hz

Service 1.9 A

RECIRCULATING INSTALLATION

61 cm and 69 cm deep wall hoods with an internal blower (1014 CMH or less), 76 cm and 91 cm widths only, can be used in a non-ducted application with a recirculating filter. In this installation, kitchen air is purified through the filters and returned as clean air into the room. A recirculation kit, avail-able through an authorized Wolf dealer is required.

Page 116: DESIGN GUIDE - Sub-Zero

116 | English

PRO VENTILATION

Installation

61 cm / 69 cm DEEP WALL HOODS

E 152mm

762 mm TO 914 mm BOTTOM EDGE TO COUNTERTOP

127mm

Page 117: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 117

Blower Assemblies

For Wolf ventilation hoods and downdrafts that do not include a blower assembly, an internal or remote blower assembly must be selected to accommodate the cooking appliance, CMH requirements, and homeowner preferences. Internal and remote blowers are avail able through an autho-rized Wolf dealer.

VENTILATION SUGGESTIONS

622mm

394mm

718mm

527mm

629mm

356mm

121mm

254 mmDIAMETER

375mm

749mm

749mm

457 mm

559mm

257mm

184mm

254mm

254 mmDIAMETER

375mm

749mm

749mm

533 mm

635mm

264mm

184mm

254mm

254 mmDIAMETER

1528 CMH REMOTE 2028 CMH REMOTE 2535 CMH REMOTE

Ventilation suggestions on the following pages provide Wolf product CMH and blower options for each ventilation hood and downdraft.

Refer to the illustrations below for the dimensions of Wolf remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications.

Page 118: DESIGN GUIDE - Sub-Zero

118 | English

VENTILATION SUGGESTIONS

Wolf Product CMH

CMH COOKTOP HOOD DOWNDRAFT PRO HOOD

COOKTOP / MODULE

ICBCI152TF/S ICBCG152TF/S 900 900 1014

ICBSM15TF/S ICBGM15TF/S 900 1014

ICBTM15TF/S ICBMM15TF/S 900 900 1014

ICBCI243TF/S ICBCI243C/B 900 1014

ICBCI304TF/S ICBCI304T/S 900 900 1014

ICBCI304C/B 900 1014

ICBCG304T/S ICBCG304P/S 900 900 1014

ICBCI365TF/S ICBCI365T/S 900 900 1014

ICBCI365C/B 900 1014

ICBCG365T/S ICBCG365P/S 900 900 1014

ICBCG365C/S 900 1014

DUAL FUEL RANGE

ICBDF304 ICBDF366 1014

ICBDF364C ICBDF364G 1528

ICBDF486C ICBDF486G ICBDF484CG ICBDF484F 1859

ICBDF606CG ICBDF604CF 1859

SEALED BURNER RANGETOP

ICBSRT304 900 1014

ICBSRT364C ICBSRT364G 1528

ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F 1528

Page 119: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 119

VENTILATION SUGGESTIONS

Wolf Ventilation Blower Options

BLOWER INTERNAL REMOTE

CMH 900 1014 1528 1859 1528 2028 2535

COOKTOP HOOD

ICBVW30B ICBVW36B ICBVW45B ICBVI42B • •

ICBVW30S ICBVW36S ICBVI42S • • • •

ICBVW36G ICBVW45G ICBVI45G • •

ICBVC36S ICBVC48S •

ICBVU24S ICBVU30S •

DOWNDRAFT

ICBDD30 ICBDD36 ICBDD45 • • • •

PRO 61 cm DEEP WALL HOOD

ICBPW362418 • • • • • •

ICBPW482418 • • • • • •

PRO 69 cm DEEP WALL HOOD

ICBPW302718 • • • • • •

ICBPW362718 ICBPW422718 • • • • • •

ICBPW482718 • • • • • •

ICBPW602718 • • • • • •

Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries.

Page 120: DESIGN GUIDE - Sub-Zero

120 | English

Wolf Appliance International Limited Warranty

FOR RESIDENTIAL USE

FULL TWO YEAR WARRANTY*

For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.

LIMITED THIRD THROUGH FIFTH YEAR WARRANTY

For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.

For more information regarding your Wolf product warranty, contact your authorized Wolf dealer. Warran-ties must comply to all country, state, city, local and or ordinance.

*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.

Page 121: DESIGN GUIDE - Sub-Zero

wolfappliance.com | 121

Wolf Appliance International Outdoor Limited Warranty*

FOR RESIDENTIAL USE

FULL ONE YEAR WARRANTY**

For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.

LIMITED FIVE YEAR WARRANTY

For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: stainless steel briquette trays, gas valves, drip pans, electronic control boards and electric heating elements. If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certified service or other sources.

For more information regarding your Wolf product warranty, contact your authorized Wolf dealer. Warran-ties must comply to all country, state, city, local and or ordinance.

*Product must be approved for outdoor use, designated by model and serial number.

**Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.

Page 122: DESIGN GUIDE - Sub-Zero

WOLFAPPL IANCE.COM