Columbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed Texture - Low Gloss - Radiant Heat Approved Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved 2mm Overall, 12mil Wear Layer - Glue Down Installation 6” wide x 48” length 60 sf/ctn (54 ctn/pal) Urethane Wear Layer, Embossed Texture, Press Bevel Edges DECEMBER 2015 Read Complete Instructions Before Installing Installation Fast Facts: Radiant Heat Approved - Hydro Systems ONLY Subfloor must be level, dry & free of imperfections Optimum room temperature for install 65°-85°F Acclimate for 48 hours prior to install Sweep & vacuum floor regularly Clean up spills immediately Recommended Adhesive: WF Taylor 2098 (Residential & Multi-Famliy) WF Taylor 2091 (Commercial) LUXURY VINYL PLANK 20yr Residential Warranty www.tasupply.com | 5yr Light Commercial Warranty CHVN8330001 Summerset CHVN879V002 Koa CHVN8320001 Coastline CHVN0660006 Pecan CHVN8340001 Newcastle CHVN704V003 Cask

Upload: lamthuan

Post on 28-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

Columbia

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

2mm Overall, 12mil Wear Layer - Glue Down Installation6” wide x 48” length 60 sf/ctn (54 ctn/pal)

Urethane Wear Layer, Embossed Texture, Press Bevel Edges

DECEMBER 2015

Read Complete Instructions Before Installing

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Famliy)WF Taylor 2091 (Commercial)

LUXURY VINYL PLANK

20yr Residential Warranty www.tasupply.com |

5yr Light Commercial Warranty

CHVN8330001Summerset

CHVN879V002Koa

CHVN8320001Coastline

CHVN0660006Pecan

CHVN8340001Newcastle

CHVN704V003Cask

Page 2: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

COLUMBIALUXURY VINYLWARRANTY What the LAMETT LVP/LVT Flooring 20 year Lim-ited Residential Warranty Covers:

Lamett warrants that from the date of original purchase this LVP/LVT floor:

• Will be free of manufacturing defects.

• Will not stain from normal household consumable items such as food or drinks.

• Will not wear through the decorative surface (scratches or loss of gloss is not considered wear)

• Will not fade as a result of direct sunlight or household lighting

What the LAMETT 5 year Limited Light Commer-cial Warranty Covers:

Lamett warrants that for 5 years of light-commercial* use from the date of original purchase this laminate floor:

• Will not wear through the decorative surface (scratches or loss of gloss is not considered wear)

• Will not fade as a result of direct sunlight or household lighting;

• Will be free of manufacturing defects.

*Light commercial is defined as light traffic commer-cial areas such as business offices and boutique shops. Heavier traffic areas, entry foyers, or any area where food is prepared or objects are rolled or dragged around are not recommend and not covered by this warranty.

PRE-INSTALLATION WARRANTY

It is the duty of the installer, whether professional or DIY (do it yourself), to inspect all flooring before instal-lation. If during inspection the installer or buyer feels the floors is the wrong color, improperly manufactured, is off-grade or is the wrong gloss level, he/she should NOT install the flooring. Please immediately contact the re-tailer from which the flooring was purchased. No claims

will the accepted for flooring which is visibly wrong if such flooring is installed. Installed flooring is deemed to be visibly acceptable.

MOISTURE WARRANTY

Lamett warrants the LVP/LVT flooring in its original manufactured state to the original purchaser from the date of purchase, under normal residential use, that the surface, when properly installed, shall be resistant to damage from normal household spills resulting in discol-oration or structural decomposition.

The Moisture Warranty does not cover flooding, stand-ing water, leaking pipes, household mechanical failures, appliance leaks or pet urine.

NO GAP WARRANTY

Lamett luxury vinyl tile products also includes a Limited 10 Year No Gap Warranty:

A gap is defined as seam separation along the long or short end of the plank under normal commercial use.

A gap must be bigger than the thickness of a business card (> 10 mils) and longer than the short side of a busi-ness card (<2”).

INSTALLATION OVER RADIANT HEAT SUB-FLOORS

We warrant to you (the original purchaser) that this Luxury Vinyl flooring may be installed over water-based radiant-heated subfloors, provided the surface temperature of the system does not exceed 81° degrees Fahrenheit (27° degrees Celsius).

IMPORTANT: Due to the speed of sudden temperature changes, which has potential to negatively affect vinyl flooring construction, it is not recommended to install over electrical radiant heating systems. This will not be covered by the manufacturer’s warranty. Only radiant

20 YEAR LIMITED RESIDENTIAL WARRANTY / 5 YEAR LIGHT COMMERCIAL

Page 1

LAMETT

Revised 7/31/2014

Page 3: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

heating system using water are acceptable.

Before installing over newly constructed radiant heat sys-tems, operate the system at maximum capacity to force any residual moisture from the cementitious topping of the radi-ant heat system. Then set the thermostat to a comfortable room temperature for the installation. It is recommended that the radiant heat be applied in a gradual manner after installing the Luxury Vinyl flooring. Refer to the radiant heat system’s manufacturer recommendations for additional guidance.

What you should do if any of the above listed problems occur:

The original residential purchaser should notify their autho-rized Lamett dealer from which the original purchase was made of any defect no later than 30 days after discovering the defect but within the same time period of this limited warranty. The original residential purchaser must present to that Authorized Lamett dealer the following items for a limited warranty claim to be considered:

• A valid proof of purchase in the form of sales receipt which establishes proof of purchase;

• A detailed description of the problem and/or a photo-graph/sample that clearly shows the warranty problem.

WHAT LAMETT WILL DO

If Lamett honors a claim under this limited warranty, it will authorize repair or replacement at the pro-rated percentage cost of the material. This percentage is determined by the number of years remaining on the warranty and the length of the warranty.

For example, if the claim is made 3 years after purchase on a Lamett product warranted for 15 years, then Lamett will pay 80% (12/15th) of the material.

If professionally installed by a certified LVP/LVT installer, Lamett will pay the reasonable labor costs to perform the replacement or repair during the first 3 years from the date of the original purchase. No labor is included for claims later than 36 months after original purchase.

LIMITATIONS AND EXCLUSIONS

If the original design/color/style is no longer available, Lamett reserves the right to substitute another Lamett design of similar structure and value from which the con-sumer may select.

This warranty does not apply to any product or products designated or sold as “B” grade, cabin grades, seconds, closeout or nonstandard items. This warranty does not ap-ply to any product or products designated or sold “As Is”.

This limited warranty is valid only in North America, is not transferable and extends only to the original purchaser

of flooring installed in the house for which was originally installed. The affected area must be visible and cover and area greater than one square inch. The flooring must be installed in accordance with Lamett recommended instal-lation instructions. This limited warranty will not apply to damage arising from any of the following:

• Installation in outdoor area’s, sun rooms, solariums, porches, garages or other area’s subject to excessive mois-ture or extremes of temperature;

• Installation in area’s where temperature falls below 50° F or goes above 104° F.

• Exposure to excessive sunlight;

• Accidents, abuse or misuse;

• Extreme heat or cold;

• Scratching, impact or cutting;

• Improper workmanship or installation not in accordance with Lamett installation instructions;

• Improper maintenance;

• Improper fabrication;

• Freight damage;

• Damages by acts of God;

• Water damage from excessive moisture in a concrete slab, hydrostatic pressure, flooding caused by ice makers, refrig-erators, sinks, dishwashers, leaking pipes, flooding, stand-ing water, spills when not promptly removed; household mechanical failures, damage caused by water underneath the flooring, including damage from sub floor hydrostatic pressure of other conditions that result in water being below the flooring or natural disasters;

• Planks coming apart at the seams because they have been engaged/disengaged more than 2 times;

• Installation cost of flooring that contains any manufactur-ing defect is not covered by this warranty.

Lamett excludes and will not pay incidental or consequen-tial damages under this warranty. By this we mean any loss, expense, or damages other than to the flooring itself that may result from a defect in the flooring. No implied war-ranties extend beyond the term of this written warranty.

Lamett assumes no liability for incidental or consequential damages. Some states do not allow the exclusion of limita-tion for incidental or consequential damages. In that case, these exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Lamett reserves the right to have a representative inspect the floor and remove samples for additional evaluation if needed. Lamett may repair, re-

Page 2

Page 4: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

finish or replace any defective product at its sole discretion.

As the sole remedy provided by this warranty, any attempt to repair, replace, or refinish prior to Lamett’s optional in-spection will void this warranty. No installer, retailer, agent or employee of Lamett has the authority to increase or alter the obligations or limitations of this warranty.Lamett assumes no liability for incidental or consequential dam-ages. Some states do not allow the exclusion of limitation for incidental or consequential damages. In that case, these exclusions may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Lamett reserves the right to have a representative inspect the floor and remove samples for additional evaluation if needed. Lamett may repair, refinish or replace any defective product at its sole discretion.

Please contact us if you have any questions. Customer Service: 1-800-562-2857

Page 3

Page 5: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

INSTALLATION INSTRUCTIONS

COLUMBIA

LUXURY VINYL

GENERAL INFORMATIONBelow are guidelines for installing Vinyl Flooring-Dry Back. Please follow these instructions carefully to ensure a successful installation of this product.

Thoroughly inspect all material. Installed flooring found to be defective will not be covered by warranty nor labor costs associated with removal and reinstallation.

All moisture tests must be performed and recorded prior to installation with results not to exceed the adhesive manufacturer’s specifications. A significant number of in-stallation failures in the market today are due to moisture related issues.

This product should be stored at the jobsite free from all the elements. This product should be acclimated to the conditioned temperature inside and must be kept at a minimum of 70° F before, during and after the installa-tion for at least 48 hours. The jobsite must be cleaned and prepared prior to starting the installation. All patch work and preparation to the subfloor must be done and allowed to dry prior to starting the installation.

Check cartons and confirm that the product is correct and has the same batch and lot number. If a different batch or lot number, to minimize shade variation mix product from several boxes. If the product looks incorrect stop the installation immediately and call your local retailer.

DO NOT: Install product with visible defect. This product is manufactured to high quality inspection standards but boxes can have occasional defective product contained inside. If you notice excessive defect stop the installation immediately and call your local retailer.

The manufacturer is not responsible for visually defective material installed.

PRE-INSTALLATION SUBFLOOR REQUIREMENTS

Proper subfloor preparation and suitable underlayment installation are essential for a trouble-free job. Uneven or rough subfloor surfaces will show through (or telegraph) to the surface of this product resulting in an unsightly sur-face and can make high spots more susceptible to exces-sive wear. Correct the subfloor imperfections before you begin installing this product.

WOOD SUBFLOORS

• Wood subfloors must be rigid and suspended at least 18” above the ground with adequate cross ventilation. Crawl space ground must be covered with suitable vapor barrier.

• Do not install this product over a wood subfloor which is directly on top of a concrete substrate or sleeper system.

• Wood subfloors must be covered with a minimum ¼” or heavier underlayment rated panel to ensure a successful installation.

• If an existing wood subfloor is damaged or not of under-layment grade, one must be put in place prior to beginning the installation of this product. The approved underlay-ment should provide a smooth and even surface for this product.

• Do not install this product over particle board, chip-board, construction grade plywood, lauan plywood, hard-board, or flakeboard.

• Wood underlayment panels should be dimensionally stable. Wood underlayment panels should be smooth and fully sanded so the graining or texturing will not show through. Wood underlayment panels should be resistant to both static and impact indentation. Wood underlayment panels should be free from any surface components that may cause staining such as plastic fillers, marking inks, sealers, etc.

• Wood underlayment panels should be uniform density, porosity and thickness.

PLEASE READ ALL INSTRUCTIONS CAREFULLY, BEFORE YOU BEGIN INSTALLATION. IMPROPER INSTALLATION WILL VOID WARRANTY.

Page 1

Revised 12/11/2015

Page 6: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

• Wood underlayment panels must have a written warranty for suitability and performance from the panel manufacturer or have a history of proven performance.

• Underlayment panels should be installed with the face grain running across the joists. Panels should be lightly butted against each other, not forced tight. End joints of the panels should be offset at least 16”. Start the installation in one corner and work diagonally across the floor.

• Use only non-staining fasteners. Do not use common steel, cement coated or some nails that are resin/rosin coated. It is not recommended to glue and screw down underlayment panels as some solvent based adhesives are known to stain vinyl flooring coverings.

• Fasteners should be staggered and no more than 4” apart around the perimeter and no more than 3/8” from the edges (6” apart across the middle of the panel). Fasteners must set flush or slightly below the surface of the underlayment. Any unevenness must be sanded level.

• Gaps, hammer indentations, and all other surface irregu-larities must be patched with a non-shrinking, water resis-tant Portland cementitious based patching underlayment compound. Do not use gypsum-based patches & leveling compounds.

CONCRETE SUBFLOORS

• Concrete subfloors must be dry, smooth and free from dust, dirt, solvent, paint, wax, grease, oil, asphalt sealing compounds and other extraneous materials. The surface must be hard and dense and free from powder of flaking.

• New concrete slabs must be allowed to dry and complete-ly prior to beginning the installation of this product, which take at least 6 weeks. Curing agents, surface hardeners and other additives may cause adhesive bond failure. All con-crete subfloors must be checked for moisture and alkalinity before installing this product.

• Do not install over any subfloor with moisture emissions higher than 5 pounds per 1000 square foot per 24 hours per a calcium chloride test.

• As in wood subfloor systems, all holes, grooves, expan-sion joints, and other depressions must be filled with a latex underlayment compound and toweled smooth and feathered even with the surrounding surface.

• Concrete floors with a radiant heating system are satisfac-tory, provided the temperature of the floor does not exceed 80° F at any point. The heating system should be turned on to eliminate residual moisture.

EXISTING RESILIENT FLOOR COVERING

NOTE: This product is not approved over existing resilient floor covering.

WARNING: Do not sand, dry scrape, bead blast or me-chanically pulverize existing resilient flooring, backing or lining felt. These products may contain asbestos fibers that are not readily identifiable. Using the above non-recom-mended procedures on asbestos containing material can create asbestos dust. The inhalation of asbestos dust may cause cancer or other serious bodily harm.

The final responsibility lies with the installer for approving the condition of the subfloor and its impact on the final look of this product.

INSTALLATION OVER RADIANT HEATWe warrant to you (the original purchaser) that this luxury vinyl flooring may be installed over water-based radiant- heated subfloors, provided the surface temperature of the system does not exceed 81° F.

IMPORTANT: Due to the speed of sudden temperature changes, which has potential to negatively affect vinyl flooring construction, it is not recommended to install over electrical radiant heating systems. This will not be covered by the manufacturer’s warranty. Only radiant heating sys-tems using water are acceptable.

Before installing over newly constructed radiant heat sys-tems, operate the system at maximum capacity to force any residual moisture from the cementitious topping of the radi-ant heat system. Then set the thermostat to a comfortable room temperature for the installation. It is recommended that the radiant heat be applied in a gradual manner after installing the luxury vinyl flooring.

Refer to the radiant heat system’s manufacturer recommen-dations for additional guidance.

GLUE-DOWN INSTALLATION1. Select proper adhesive according to specific types of subfloor and planks. With the approved/proper adhesive apply a 1/16” wide, 1/16” deep, 1/16” apart square notched trowel.

2. Snap a chalk line to divide the room into sections. Begin applying adhesive at an intersection and spread the appro-priate amount.

Recommended Adhesive: WF Taylor 2098 (Residential & Multi-Family) WF Taylor 2091 (Commercial)

WET SET (ALL PLANKS)

1. Spread the adhesive in a thin even coat. Each section must be no larger than at area that can easily be covered with flooring is approximately 20 minutes under normal conditions (70° F and 40% humidity). Allow a few minutes of open time for the adhesive to tack up, then install the planks immediately while adhesive is still wet, before it

Page 2

Page 7: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

skins over or dries.

2. Position the plank firmly in adhesive without sliding and periodically check to ensure at least 90% of the adhesive pattern has transferred to the back of the tile.

3. Use a large tile cutter or the score and snap technique for fitting planks or tiles around the border.

DRY SET (ALL TILES)

1. Spread the adhesive in a thin even coat. Allow adhesive to dry until it changes color and will not transfer to finger when touched. Dry adhesive is extremely tacky.

2. Lay tile into dry adhesive positioning carefully because it will be difficult to slide the tile.

3. Roll each section immediately upon completing with a 100 pound, three section roller. Re-roll the entire floor after one or two hours then again after the installation in both directions.

4. Remove any excess adhesive immediately with soapy water. Dried adhesive is difficult to remove. Cover all exposed edges.

5. Install wood or vinyl shoe/cove moldings along the walls, cabinet toe kicks, etc.

6. Install transitions moldings and caulk along tubs, toilets, etc. Dried adhesive should be removed with an approved non-flammable cleaner or solvent.

7. Do not wash or treat the floor for a minimum of 48 hours after installation. After 48 hours, damp mop to remove residual surface dirt.

INITIAL CARE AFTER INSTALLATION1. Immediately after installation, the floor should be dry vacuumed to remove all dust and debris.

2. Then wipe with a vinyl flooring cleaner (any generic brand cleaner specifically made for cleaning vinyl flooring) using a sponge mop or similar cloth-applicator mops. Be sure to follow the vinyl cleaner manufacturer’s instructions.

3. After 5-10 minutes, all residue of the cleaning agent should be removed and the floor should be rinsed with a damp mop.

4. Your floor should then be allowed to dry for at least 30 minutes before walking on it.

CARE AND MAINTENANCEPREVENTATIVE MAINTENANCE

• Clean protective mats in front of any doors leading to the outside. This helps limit the amount of sand and grit from getting on to your vinyl floors. Gritty sand is any floor

coverings worst enemy. Also, if you installed the planks in your kitchen, you should place a throw rug is front of the sink area to catch spills and splashes. If the rug gets soak it should be removed and allowed to dry.

• Install proper floor protectors of furniture legs used on vinyl flooring. Protectors will allow chairs to move easily over the floor without scuffing or scratching. Clean the pro-tectors on a regular basis to remove any grit that may have become embedded.

• To keep you floor looking its best, dust mop or vacuum your floor frequently. Do not use household dust treatment chemicals of any kind as this may cause the floor to become slick or dull the finish. Simply sweep the floor as needed.

• Do not pour pails of water on your floor to clean or use excessive water. This can damage your subfloor.

• Do not allow pets with untrimmed nails to walk on the vinyl floor. It could cause severe scratching to the surface.

REGULAR MAINTENANCE

• Clean up food spills as quickly as possible.

• Avoid acidic or abrasive all-purpose cleaners, powdered cleaners, oil soaps, dish washing detergents, and dusting products.

• Shoe marks and scuffs can be removed by spot cleaning with a non-abrasive all purpose cleaner and a non-abrasive scrubbing pad.

• Regular household dirt can be cleaned by damp cleaning with warm soapy water.

• Always sweep and vacuum your vinyl floor before clean-ing.

• If accidental deep scratches occur then it might be neces-sary to replace individual planks. Always retain some extra product for this instance.

• To replace: score the plank diagonally with a utility knife and make sure not to damage adjacent planks. Point a hair dryer about 4 inches from the center of the tile for about 45 seconds or until it is hot to the touch. Pry up the plank start-ing from the middle. More heat may be necessary to work the piece. Smoothen the subfloor surface (use floor patching or leveling compound sparingly) and reapply adhesive.

• Avoid moving heavy furniture on to a newly installed floor for at least 24 hours.

• Avoid excessive heat and light exposure to the flooring which will cause degradation of the product.

Page 3

Contact your flooring retailer with questions or concerns regarding your flooring purchase.

Page 8: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN879V002

COLORKoa

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 9: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN8320001

COLORCoastline

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 10: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN8330001

COLORSummerset

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 11: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN8340001

COLORNewcastle

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 12: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN704V003

COLORCask

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 13: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive:WF Taylor 2098 (Residential & Multi-Family)WF Taylor 2091 (Commercial)

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

PACKAGING60 sf/ctn | 54 ctns/plt

DIMENSIONS2mm t x 6” w x 48” l

ITEM #CHVN0660006

COLORPecan

Read Complete Instructions Before Installing

www.tasupply.com |

DECEMBER 2015

IN

PR

FN

PA

DM

SKU

CL

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved

LUXURY VINYL PLANK

Columbia

Page 14: DECEMBER 2015 - Glue Down - Urethane Wear Layer ... /Columbia_Website_MAR2015.pdfColumbia - Glue Down - Urethane Wear Layer - Residential & Commercial - Press Bevel Edge - Embossed

LUXURY VINYL PLANK

PACKAGING60 sf/ctn | 54 ctns/plt

INSTALLATION METHODGlue Down

PROFILEPress Bevel Edge | 12mil Wear Layer

FINISHEmbossed Texture

DIMENSIONS2mm t x 6” w x 48” l

COLOR6 Colors

PA

IN

PR

FN

DM

CL

www.tasupply.com |

- Glue Down- Urethane Wear Layer- Residential & Commercial- Press Bevel Edge- Embossed Texture- Low Gloss- Radiant Heat Approved Columbia

20yr Residential Warranty

5yr Light Commercial Warranty

Traditional Glue Down Installation Method Low Gloss Urethane Wear Layer - Hides Scratches

Warranted for Residential & Commercial Applications Press Bevel Edges for Best Installation Results

Embossed Texture for Realistic Wood Visual Bonus Feature - Radiant Heat Approved

Installation Fast Facts:Radiant Heat Approved - Hydro Systems ONLYSubfloor must be level, dry & free of imperfectionsOptimum room temperature for install 65°-85°FAcclimate for 48 hours prior to installSweep & vacuum floor regularlyClean up spills immediately

Recommended Adhesive: WF Taylor 2098

Read Complete Instructions Before Installing

DECEMBER 2015