d08 solenoid controlled, pilot operated valves

8
D08 Solenoid Controlled, Pilot Operated Valves Available in 4 Way 2 & 3 Position Various Spool Configurations and Voltages Nominal Flow Rates up to 70 gpm Same Day Shipments www.FluiDyneFP.com

Upload: others

Post on 22-Feb-2022

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D08 Solenoid Controlled, Pilot Operated Valves

D08 Solenoid Controlled, Pilot Operated Valves• Availablein4Way2&3Position• VariousSpoolConfigurationsandVoltages• NominalFlowRatesupto70gpm• SameDayShipments

www.FluiDyneFP.com

Page 2: D08 Solenoid Controlled, Pilot Operated Valves

Model Code Breakdown

Response TypeX* – Fast responseBlank – Standard low shock models

1* – Stroke adjustment both ends2 – Pilot choke (dual) adjustment3* – Pilot choke and stroke adjustment7* – Stroke adjustment A port end only8* – Stroke adjustment B port end only2-7*– Dual pilot choke and stroke

adjustment A port end only2-8*– Dual pilot choke and stroke

adjustment B port end onlyBlank – Omit if not required

Pilot Pressure

E - External pilot pressureBlank - Internal pilot pressure

Pilot Drain

T – Internal pilot drainBlank – External pilot drain

Pressure Port Check ValveK* – 5 psi cracking pressureR* – 50 psi cracking pressureS – 75 psi cracking pressureBlank – Omit if not required

Spool/Spring ArrangementA –B – Spring centered, solenoid A

removedC – Spring centered

Left Hand AssemblyL – Left hand, single solenoid on

(For right hand assembly P to A port whensolenoid A is energized.)

Blank – Omit if not required

Manual OverrideBlank – Plain override solenoid

ends only

WF - FluiDyne brand

Series DesignationD – Directional control valveG – Manifold or subplate mounted5 – Solenoid controlled, pilot operated

Interface

S8 - D08

Spool TypeCod e Center position0 – Open to T all ports1* – Open P & A to T, closed B2 – Closed to T all ports3 – Closed P & B, open A to T4 – Tandem P to T, closed to P crossover6 – Closed P onl y, open A & B to T7 – Open P to A & B, closed T8 – Tandem P to T, open crossover9* – Open to T all ports over tapers11* – Open P & B to T, closed A31 – Closed P & A, open B to T33 – Closed P, open A & B to T

over tapers

1

2

3

4

5

6

7

8

9

10

11

12

3 4 5 876 9 101 2 11 12 13 14 15 16 17 18 19 20 21 22 23 24

WF - DG5- ** * * (*) -(*)-(E) - (T) (*)- ( ) M-(S*) * (**)* * (L)-** 5- *** 60/70

SH8 - D08H

Spool Control Modifications

Solenoid Energization IdentityV – Solenoid identification determined

by position of solenoid (solenoid Aat port A end and/or solenoid B atport B end)

Blank – Standard arrangement for ANSIB93.9 (energize solenoid A for flowP to A port)

(Code V for any valve with code 4 orcode 8 spool)

13

Flag SymbolM – Electrical options and features

Spool Indicator Switch*(Available on models with highperformance pilot DG4V3 only)

S3 – Normally open (available onvalves with code P* only)

S4 – Normally closed (available onvalves with code P* only)

S5 – Free leads (available onvalves with coil type code F only)

S6 – LVDT type DC switch

Coil TypeU – ISO 4400

14

15

16

F – Flying Lead

Call us Today for a Quote! (586) 296-7200

Model Code Breakdown Continues on the Next Page!

* Only Available in Reman

Page 3: D08 Solenoid Controlled, Pilot Operated Valves

Model Code Breakdown (continued)

Electrical Connections(Code F coil only)

T* – Wired terminal blockPA*– Instaplug male receptacle onlyPB*– Instaplug male & female receptaclePA3 – Three pin connectorPA5 – Five pin connectorBlank – Omit if not required

Housing(Code F coil only)

W – 1/2 NPT thread wiring housingBlank – Omit if not required

Electrical Options(Code U coil only)

ISO with fitted plug and lights

Solenoid Indicator Lights(Code F coil with code T electricalconnections only)

L – Indicator lightsBlank – Omit if not required

Coil IdentificationA* – 110V AC 50 HzB – 110V AC 50 Hz/120V AC 60 Hz*C* – 220V AC 50 HzD – 220V AC 50 Hz/240V AC 60 Hz*G – 12 VDCH – 24 VDCDJ*– 98 VDCP* – 110 VDC

19

20

21

Pilot Valve Tank Pressure Rating2* – 10 bar (145 psi) WFDG4V3S-60 with

S3, S4, or S5 spool indicatorswitch

5 – 100 bar (1450 psi) WFDG4V3S-606 – 160 bar (2300 psi) with WF4WE6-6X

AC solenoids 7 – 210 bar (3000 psi) WF4WE6-6X with

DC solenoids

Pilot Valve Port OrificesCode Orifice diameter*00– Solid plug*03– 0,30 mm (0.012 in)*06– 0,60 mm (0.024 in)*08– 0,80 mm (0.030 in)*10– 1,00 mm (0.040 in)*13– 1,30 mm (0.050 in)*15– 1,50 mm (0.060 in)*20– 2,00 mm (0.080 in)*23– 2,30 mm (0.090 in)Blank – Omit if not required(* = P, T, A, and/or B as required)

Design Number

22

23

24

18

17

60 – WFDG4V3S-60 Pilot Valve (Std performance)

70 – WF4WE6-6X Pilot Valve (High performance)

Blank – Response TypeX – Fast responseBlank – Standard low shock models

1 – Stroke adjustment both ends2 – Pilot choke (dual) adjustment3 – Pilot choke and stroke adjustment7 – Stroke adjustment A port end only8 – Stroke adjustment B port end only2-7 – Dual pilot choke and stroke

adjustment A port end only2-8 – Dual pilot choke and stroke

adjustment B port end onlyBlank – Omit if not required

Pilot Pressure

E - External pilot pressureBlank - Internal pilot pressure

Pilot Drain

T – Internal pilot drainBlank – External pilot drain

Pressure Port Check ValveK – 5 psi cracking pressureR – 50 psi cracking pressureS – 75 psi cracking pressureBlank – Omit if not required

Spool/Spring ArrangementA –B – Spring centered, solenoid A

removedC – Spring centered

Left Hand AssemblyL – Left hand, single solenoid on

Omit if not required. (For right handassembly , P to A port whensolenoid A is energized.)

Blank – Omit if not required

Manual OverrideBlank – Plain override solenoid

ends only

WF - FluiDyne brand

Series DesignationD – Directional control valveG – Manifold or subplate mounted5 – Solenoid controlled, pilot operated

Interface

S8 - D08

Spool TypeCod e Center position0 – Open to T all ports1 – Open P & A to T, closed B2 – Closed to T all ports3 – Closed P & B, open A to T**4 – Tandem P to T, closed to P crossover6 – Closed P onl y, open A & B to T7 – Open P to A & B, closed T**8 – Tandem P to T, open crossover9 – Open to T all ports over tapers11 – Open P & B to T, closed A31 – Closed P & A, open B to T33 – Closed P, open A & B to T

over tapers

1

2

3

4

5

6

7

8

9

10

11

12

3 4 5 876 9 101 2 11 12 13 14 15 16 17 18 19 20 21 22 23 24

WF - DG5- ** * * (*) -(*)-(E) - (T) (*)- ( ) M-(S*) * (**)* * (L)-** 5- *** 60/70

SH8 - D08H

Spool Control Modifications

Solenoid Energization IdentityV – Solenoid identification determined

by position of solenoid (solenoid Aat port A end and/or solenoid B atport B end)

Blank – Standard arrangement for ANSIB93.9 (energize solenoid A for flowP to A port)

(Code V for any valve with code 4 orcode 8 spool)

13

Flag SymbolM – Electrical options and features

Spool Indicator Switch(Available on models with highperformance pilot DG4V3 only)

S3 – Normally open (available onvalves with code P* only)

S4 – Normally closed (available onvalves with code P* only)

S5 – Free leads (available onvalves with coil type code F only)

S6 – LVDT type DC switch with Pg7connector plug

Coil TypeU – ISO 4400

14

15

16

Technical Data for Pilot Pressure

Style

NG Size 22 25Vickers DG5S8 DG5SH8

FluiDyne WFDG5S8 WFDG5SH8Rexroth 4WH22 4WH25FluiDyne WF4WEH22 WF4WEH25

Pilot Oil Supply X External3-positionvalvespring-centered psi 152 1883-positionvalve,pressure-centered psi - 2612-positionvalvewithspringendposition psi 159 1882-positionvalvewithhydraulicendposition psi 116 116Pilot Oil Supply X Internal psi 65 65

Valves should be installed in the horizontal position! Filtered hydraulic oil should be at least 20 micron.

* Only Available in Reman

Page 4: D08 Solenoid Controlled, Pilot Operated Valves

Spool Type and Spring Mechanism

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

ab

A B

P T

ab

A B

P T

ab

A B

P T

ab

2C

0C

6C

7C

8C 8B

7B

6B

0B

2B 2BL

0BL

6BL

7BL

8BL

2A

0A

2AL

0AL

203

PSI

174

145

116

87

58

29

MEGAPASCAL

Function code 8C spool in middle position P to T

Flow L/min(GPM)

100(26)

200(52)

400(105)

600(158)

300(79)

500(132)

D08 Specification

Function Switching Position

P a A P a B A a T B a T2C 1 1 1 37C 1 4 3 38C 3 1 2 40C 4 4 3 46C 2 2 3 5

www.FluiDyneFP.com

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

abA B

P T

bA B

P T

a

A B

P T

ab

A B

P T

ab

A B

P T

ab

A B

P T

ab

2C

0C

6C

7C

8C 8B

7B

6B

0B

2B 2BL

0BL

6BL

7BL

8BL

2A

0A

2AL

0AL

203

PSI

174

145

116

87

58

29

MEGAPASCAL

Function code 8C spool in middle position P to T

Flow L/min(GPM)

100(26)

200(52)

400(105)

600(158)

300(79)

500(132)

Page 5: D08 Solenoid Controlled, Pilot Operated Valves

Pilot Oil & Drain Plugging

PT

X A

2

5T

X Y

1

P T 3

4

DG5S8 (NG25)

1 PlugscrewM6,3A/F-pilotoildrain2 PlugscrewM6,3A/F-pilotoilsupply3 PilotValve4 MainValve5 EndCover

Pilot Oil Supply Pilot Oil Drain External: 2closed External: 1closedInternal: 2open Internal: 1open

NG10andNG16:35Nm[25.8ft-lbs];NG25:68Nm[50.2ft-lbs]Tighteningtorquesforcovermountingscrews

Valve Model Code Additions:

Blank = Int. Pilot Blank = Ext. Drain E = Ext. Pilot T = Int. Pilot

Type ET: ThepilotoilissuppliedexternallyviachannelXfromaseperatepressuresupply.ThepilotoilisdrainedinternallyviachannelTtothetank.PortsXandYinthesubplateareplugged.

Type E: ThepilotoilissuppliedexternallyviachannelXfromaseparatepressuresupply.ThepilotoilisdrainedexternallyviachannelYtothetank.PortXinthesubplateisplugged.

Type T: ThepilotissuppliedinternallyfromchannelPofthemainvalve.ThepilotoilisdrainedinternallyviachannelTtothetank.PortYinthesubplateisplugged.

Providing Solutions that Work

Page 6: D08 Solenoid Controlled, Pilot Operated Valves

D08 Drawings

page 5 1/10/2020

Direct Current Din Plug

Direct Current Wire Box

www.FluiDyneFP.com

Page 7: D08 Solenoid Controlled, Pilot Operated Valves

D08 Drawings

Alternating Current Din Plug

Alternating Current Wire Box

www.FluiDyneFP.com

Page 8: D08 Solenoid Controlled, Pilot Operated Valves

Powered by Customer Service!

Call, email, chat...we’re ready to help!

FluiDyne supports the distributors providing localknowledge and assistance to fluid power customers.

Our people provide extensive support:

EngineeringExpertise Componentfailure analysisDecodingspecial partnumbers 18monthwarrantyIdentificationof Newapplicationpartswithinunits componentselection

Adviceoncomponent Samedayshipmentrepairandassembly

Reman Units & Parts Available for Racine,Oilgear, Bosch, Continental and More!

01/2020

l

l

l

l

l

l

l

l

Formostrecentbrochure,andinformationonourotherproductspleasevisitwww.fluidynefp.com