D MS 500 KE VIS
Data Communicativisualization ability
D‐MS 500 KE VIS
y
D-MS 500 KE VIS with 19“ keyboard aplug-in monitor
3HU box, 1HU keyboard, monitor for 19“ c Linux operation system Interfaces for components:
Modbus, Profibus, OPC, (0/4)...20 mA, bina Capacity up to 64 analouge / 128 d
64 l / 128 d64 analouge / 128 d Data buffering:
resolution 1 sec. up to 96 days Interfaces:
2 x Ethernet RJ45, 4 x USB 2.0, 1*RS485, 2* Languages: English & German
ion Unit withy on-sitey
and
Data logger functionality withVisualization possibility on-sitePart of the System D-EMS 2000incl. digital Interfaces according toVDI 4201
Innovative DURAG CPU 440
cabinet installation
ary signals,digital inputsdi it l t tdigital outputs
*RS232, DVI,
Communication unitidentical with D‐MS 500 KE,but also with additionallypossibility of a visualization/operation on‐site
Other feature
o Part of the TÜV suitability checkedsystem D‐EMS 2000
o Necessary are monitor, mouse, keyboard(desktop, 19“ plug‐in design)
o Connection to D‐EMS 2000 System via Ethernet
o Remote service via Intranet
Functional characteristicsThe data communication unitD‐MS 500 KE VIS enables not onlyvisualization of raw values but also representation of the resulting minute andintegral values in SXGA resolution(1280x1024 Pixel). In order for the maintenance and testing by testing laboratories (eg AST) necessary information is available on site.The system programming can be performed locally or via remote accesslocally or via remote access.
CommunicationThe data communication unitD‐MS 500 KE VIS is the connection between the process and the official evaluation. The recorded raw values (with a resolution of 1 sec) are transmitted over to the system workstation D‐EMS 2000 SW via Ethernet
Top:Tabularworkstation D EMS 2000 SW via Ethernet,
integrated, normalized and classified in accordance with official regulations. These authorities relevant values are stored in a database and are available for on‐sitevisualization. All calculated minutes andintegral values can be represented in tabular form. The visualization of raw data and the input signals is direct and is active
i h i i i h h
Tabularrepresentationof integral values
n
even without communication with the system workstation D‐EMS 2000 SW.
DURAG data systems GmbH ∙ Kollaustraße 10522453 Hamburg ∙ Tel. +49 40 55 42 18‐3000Fax +49 40 55 42 18‐3099
www.durag‐data.de
dds 21/06/2012 ∙Änderungen vorbehalte
DURAG, Inc., USA ∙ E‐Mail:DURAG China ∙ E‐Mail: infoDURAG India Ltd. ∙ E‐Mail: DURAG France ∙ E‐Mail: inf
Left:Tabularrepresentationof the raw values
Top:Tabularrepresentationof the minuteaverage values
Top: Channel filter withchannel selection
: [email protected]@durag‐[email protected]@durag‐france.fr
DURAG Italia S.r.l. ∙ E‐Mail: [email protected] Japan Office ∙ E‐Mail: [email protected] Brazil Office ∙ E‐Mail: [email protected]
Left: Parameterization with„KEshow“