D MS 500 KE VIS Data Communicati visualization ability DMS 500 KE VIS D-MS 500 KE VIS with 19“ keyboard a plug-in monitor 3HU box, 1HU keyboard, monitor for 19“ c Linux operation system Interfaces for components: Modbus, Profibus, OPC, (0/4)...20 mA, bina Capacity up to 64 analouge / 128 d 64 l / 128 d 64 analouge / 128 d Data buffering: resolution 1 sec. up to 96 days Interfaces: 2 x Ethernet RJ45, 4 x USB 2.0, 1*RS485, 2* Languages: English & German ion Unit with y on-site and Data logger functionality with Visualization possibility on-site Part of the System D-EMS 2000 incl. digital Interfaces according to VDI 4201 Innovative DURAG CPU 440 cabinet installation ary signals, digital inputs di it l t t digital outputs *RS232, DVI,

Upload: others

Post on 20-Nov-2021

84 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D MS 500KEVIS MS 500 - DURAG

D MS 500 KE VIS

Data Communicativisualization ability

D‐MS 500 KE VIS

y

D-MS 500 KE VIS with 19“ keyboard aplug-in monitor

3HU box, 1HU keyboard, monitor for 19“ c Linux operation system Interfaces for components:

Modbus, Profibus, OPC, (0/4)...20 mA, bina Capacity up to 64 analouge / 128 d

64 l / 128 d64 analouge / 128 d Data buffering:

resolution 1 sec. up to 96 days Interfaces:

2 x Ethernet RJ45, 4 x USB 2.0, 1*RS485, 2* Languages: English & German

ion Unit withy on-sitey

and

Data logger functionality withVisualization possibility on-sitePart of the System D-EMS 2000incl. digital Interfaces according toVDI 4201

Innovative DURAG CPU 440 

cabinet installation

ary signals,digital inputsdi it l t tdigital outputs

*RS232, DVI,

Page 2: D MS 500KEVIS MS 500 - DURAG

Communication unitidentical with D‐MS 500 KE,but also with additionallypossibility of a visualization/operation on‐site

Other feature

o Part of the TÜV suitability checkedsystem D‐EMS 2000 

o Necessary are monitor, mouse, keyboard(desktop, 19“ plug‐in design)

o Connection to D‐EMS 2000 System via Ethernet

o Remote service via Intranet

Functional characteristicsThe data communication unitD‐MS 500 KE VIS enables not onlyvisualization of raw values but also representation of the resulting minute andintegral values in SXGA resolution(1280x1024 Pixel). In order for the maintenance and testing by testing laboratories (eg AST) necessary information is available on site.The system programming can be performed locally or via remote accesslocally or via remote access.

CommunicationThe data communication unitD‐MS 500 KE VIS is the connection between the process and the official evaluation. The recorded raw values (with a resolution of 1 sec) are transmitted over to the system workstation D‐EMS 2000 SW via Ethernet

Top:Tabularworkstation D EMS 2000 SW via Ethernet,  

integrated, normalized and classified in accordance with official regulations. These authorities relevant values are stored in a database and are available for on‐sitevisualization. All calculated minutes andintegral values can be represented in tabular form. The visualization of raw data and the input signals is direct and is active 

i h i i i h h

Tabularrepresentationof integral values

n

even without communication with the system workstation D‐EMS 2000 SW.

DURAG data systems GmbH ∙ Kollaustraße 10522453 Hamburg ∙ Tel. +49 40 55 42 18‐3000Fax +49 40 55 42 18‐3099

www.durag‐data.de

dds  21/06/2012 ∙Änderungen vorbehalte

DURAG, Inc., USA ∙ E‐Mail:DURAG China ∙ E‐Mail: infoDURAG India Ltd. ∙ E‐Mail: DURAG France ∙ E‐Mail: inf

Left:Tabularrepresentationof the raw values

Top:Tabularrepresentationof the minuteaverage values

Top: Channel filter withchannel selection

[email protected]@durag‐[email protected]@durag‐france.fr

DURAG Italia S.r.l. ∙ E‐Mail: [email protected] Japan Office ∙ E‐Mail: [email protected] Brazil Office ∙ E‐Mail: [email protected]

Left: Parameterization with„KEshow“