Improved MRI Cancer Imaging Using Gadolinium as the Contrast Agent in Short
Single Walled Carbon Nanotubes
Dr. Mary Frame McMahon
Group CJuan Bastidas
Eric D’AmbrosioMohammad Reda El Mkhantar
James MutinoPeter NazaroffJaekang Yoo
Faculty Advisor Dr. Balaji SitharamanUndergraduate TA Samantha Rossano
Background
Cancer is a disease that has been found in humans and other animals
since the beginning and has become recently more infamous. According to the
American Cancer Society website over 13 million people in the United States
have had some sort of invasive cancer, and that one in three Americans will have
some sort of cancer in their lifetime[1].
Cancer is a disease caused by unregulated cell growth of abnormal cells.
Cells become cancer cells because of some sort of DNA damage. DNA damage
can come from a wide range of places; mutations can be genetically inherited,
caused by some malfunction in cellular mitosis or caused by external forces such
as radiation[1]. There are even viruses known as Oncoviruses, which can cause
cancer[1].
Cells become cancerous when they continue to grow and proliferate when
they shouldn’t be. In eukaryotic cells, cell division occurs by two processes,
mitosis and meiosis. Meiosis is only used to create gametes for sexual
reproduction. Mitosis occurs in humans for reasons such as growth and repair
and is usually regulated by certain checkpoints. The first checkpoint is known as
the G1 checkpoint or the restriction checkpoint[6]. This checkpoint is where the
cell decides whether it should divide, delay division or enter a resting phase.
Their surrounding cells, or environmental conditions signal healthy human cells
when it is time to enter mitosis [6]. Cancerous cells proliferate no matter what
kind of external signaling they receive[1].
Cancer cells can sometimes form into clumps that are known as tumors.
Many methods for detecting cancer involve the imaging of tumors, however some
cancers such as leukemia (cancer of the blood cells) do not form tumors and
some tumors aren’t cancerous [1]. Tumors that are benign can grow and press
up against other organs, but will not spread. The spreading of cancerous cells
from their point of origin to other organs is known as metastasis[6]. Tumors that
are capable of metastasis are known as malignant tumors[1].
The first recorded description of cancer was in Egypt around 3000 B.C.
and refers to 8 cases of tumors on the breast [1]. The origin of the word Cancer
comes from the Greek “carcinos” and “carcinomas”, which Hippocrates used to
describe tumors that did or did not cause ulcers[1]. Like most other diseases, the
lack of technology severely limited our early understanding of cancer. The
development of certain enabling technologies and improvements in cancer
imaging has improved our understanding of this disease dramatically.
Until the 19th century and the development of the modern microscope,
most information from cancer came from autopsies. During the 1700s John
Hunter, the Scottish surgeon, suggested that certain cancers could be
removed[2]. However without any sort of imaging technology a surgeon would be
forced to go into surgery blind and try to find the tumor and hopefully it could be
removed.
With the invention of the compound light microscope and the work of
Rudolf Virchow the study of cancer pathology was born. Virchow used
microscopes to study cancerous tissues at the microscopic level[2]. His work
allowed him to study the damage that cancer did to tissues, and also allowed the
study of tumors once they had been removed to obtain a better diagnosis.
The 19th century also saw an increase in cancer imaging technology.
Inventions such as the gastroscope and the cystoscope were invented in the late
1800s and used to detect cancer in the lower esophagus/stomach and bladder,
respectively [2]. In 1896 Dr. Franz Konig used the newly invented x-ray to
examine a leg that he had amputated and discovered that there was a sarcoma
of the tibia [2]. The invention of the X-ray and the discovery that it can be used to
find tumors inside of the body started the modern age of cancer imaging and
paved the way for more advanced imaging techniques[2].
During the twentieth century we observed the use of our most advanced
technologies in the field of cancer imaging and the invention of techniques that
we use today. In 1902 Willem Einthoven took the first ECG reading; ECG’s are
used to diagnose renal cancer [2]. In 1941 George Papanicolaou invented the
technique known as the Pap smear for detecting pre-cancerous and cancerous
cells inside the female genital tract [2]. In 1951 Raul Leborgne used a cone and
compression pad to X-ray human breasts in order to image breast cancer, and
paved the way for the modern mammogram [2].
The 1970s saw monumental improvement in cancer imaging and gave
birth two three of our modern forms of noninvasive medical imaging. In 1972
Godfrey Hounsfield used X-ray imaging and computer assisted analysis to create
cross sections of organs and other body parts[2]. This invention is known as the
CT scan.
In 1974 the first positron emission topography scanner was used[2]. PET
scanners use the detection of radiation from chemicals introduced to the body to
produce a high-resolution computerized image, which show biochemical activity
of observed structures. In 1973 one of the most important inventions in modern
cancer imaging came into existence[2]. Magnetic resonance imaging reads a
radio frequency emitted by excited hydrogen atoms in the body as the result of a
large and uniform magnetic field[13].
Before MRI, we used x-ray to investigate human body [6]. There are two
ways to use X-ray, conventional x-ray imaging and computer tomography [6].
To begin with, x-ray is a form of electromagnetic radiation. It can pass
through solid objects so that it can be used to create images of human body, in
which the image is a spatial map of the object’s susceptibility to penetration by
the rays [6]. X-rays have two useful properties for imaging [6]. First, X-rays
penetrate the human body translucently at certain wavelengths [6]. It means the
rays pass through the body, also, they are partially absorbed as they penetrate at
the same time [6]. The denser tissue density there is in the path of the x-rays, the
more the fraction of radiation that is absorbed [6]. Second, x-rays have the ability
to expose photographic film like visible light [6].
For conventional x-ray imaging, the x-ray beam penetrated through a
body and will expose film [6]. An x-ray image is a negative image [6]. The film is
darker where the tissue of the body is less dense and lighter where is more
dense, which means dark parts occur where the body has lighter elements such
as flesh, allowing more x-rays to penetrate through [6]. In contrast, light regions
occur where the body is dense with heavier elements such a bones, which allows
fewer x-rays to expose the film [6]. In other words, an x-ray image is like a
shadow [6]. The conventional x-ray process can just make two-dimensional
image with three-dimensional body [6]. It just represents the penetration of
radiation through the body onto a two-dimensional plane [6]. This kind of image is
called a projection [6]. X-ray images can be used in medical inspection because
it can show fractures and breaks in bones, fluid in lungs, cavities in teeth and
cancer in breasts [6]. If there is a big difference in the density of the tissue, such
as with soft tissue and air, bone and soft tissue, or water and soft tissue, it can
provide good contrast and make nice images [6]. The most common applications
of x-ray imaging is the chest x-ray, which physicians use to search infection
within the lungs, fractures in the bones of the rib cage, and certain kinds of heart
disease [6].
However, CT uses x-rays in a different way. It uses x-ray to
produce images of specific areas of the scanned object, which allows the user to
see what is inside it without cutting it open [6]. When the patient goes into the CT
imaging system, rotating x-ray sources work within the circular opening, and x-
ray detectors also rotates in synchrony all around the patient [7]. The x-ray
source makes a narrow, fan-shaped beam [7]. The patient is moved into x-ray
generator and the detectors and it can create an image of one cross-section
through the body at a time [6]. The table moves the patient’s position to image
each slice [6]. Computer will process all the data to prepare a series of image
slices into a three-dimensional view of the certain organ or body region [7].
However, since CT uses x-rays to make images, there can be a risk of damage
to DNA in human body, which can cause cancer [7]. In comparison, MRI does
not use x-rays and there is less chance to expose to damage [6].
MRI, which is used as device in this paper, is a medical imaging
technique by visualizing internal structures of the body [6]. It provides detailed
three-dimensional images, especially of soft tissue that cannot easily be imaged
in other modalities, such as CT [6]. MRI is also pretty versatile. We can use it in
many different ways such biochemical composition, tissue function, and
molecular diffusion, as well as structure [6]. MR scans properties of the magnetic
dipole (spin) of atomic nuclei at magnetic fields [6]. It uses hydrogen nuclei
(protons), which will be aligned in a large magnetic field [6]. When a person is
placed into the magnetic field of an MR scanner, the magnetic moment vectors of
their hydrogen nuclei align parallel with the direction of the field [6]. A short radio
frequency of electromagnetic radiation is applied in a plane perpendicular to
magnetic field, creating a new magnetic field, which is called transverse magnetic
field [6]. This radio frequency is known as the resonance frequency that flips the
spin of the protons in the magnetic field [6]. After the electromagnetic field is off,
the hydrogen nuclei spontaneously begin to return to their original equilibrium
configuration [6]. During this process, they release RF energy, which can be
found by the receiver coils surrounding the person [6]. The produced signals are
recorded and the resulting data are processed to generate an image [6].
Hydrogen nuclei in different parts return to their original equilibrium configuration
at different relaxation rates [6]. The returning time to equilibrium position is
categorized by the longitudinal relaxation time (T1) and the transverse relaxation
time (T2) [6]. The amount of brightness in MR is resulted by proton density, T1
relaxation, and T2 relaxation within the particular tissue [6]. T1 relaxation shows
nice contrast for different types of soft tissue, while T2 relaxation is good for
pathology [6].
MRI imaging has improved since 1973 with the advancement of
computers and the technology surrounding the MRI [2]. However the MRI
scanner is still limited in resolution by the T1 relaxation times of hydrogen atoms,
which is about 3600 ms [33]. Finding small masses of tissue that don’t belong
can be difficult with this limited resolution [33]. In order to identify tumors in a
more efficient way there needs to be better contrast in MRI imaging[33].
Thanks to the nature of the MRI machine, there are certain chemicals and
chemical compounds that improve the contrast of MRI images. The fact that MRI
becomes common in use of medical purpose has made the invention of a new
kind of pharmacological products, which is called contrast agents [8]. MRI
contrast agents are injected to enhance the image of blood vessels, tumors or
inflammation [8]. By far the most common is the gadolinium-based agents [8].
Gadolinium is a high paramagnetic ion with seven unpaired electrons and has
comparably long electronic relaxation time, which makes it an excellent
relaxation agent [8]. It disturbs the local magnetic field of nearby protons and
results in a shortening T1 and T2 relaxation time [8]. It means relaxation rate
increases, either longitudinal (1/T1) or transverse (1/T2) [8].
These MRI contrast agents have a shorter T1 time then hydrogen atoms
and help MRI images produce a more detailed image of the area in question[8].
Most MRI contrast agents are derivatives of the Gadolinium^3+ ion[4].
Gadolinium is a silvery white metal that is malleable and ductile [3]. What
makes Gadolinium important as a contrast agent is it’s symmetry, magnetism
and the fact that it has the highest number of unpaired electron spins (7 unpaired
electrons) [3] , which gives Gd(III) at 5 ppm a T1 time of 1600 ms [33]. This
shortened T1 relaxation time produces a clearer image in an MRI and makes
spotting things like tumors much easier[5].
Gadolinium is a very useful tool in cancer imaging, but unfortunately there
are some problems that can arise from its use. Gadolinium has been known to
cause a rare but serious disease in some people who have kidney problems [4].
This disease is called Nephrogenic Systematic Fibrosis (NSF) and causes
fibrosis in the skin and connective tissue and can even result in death [4]. If there
was a way that Gd(III) could be in the body so that it could improve MRI contrast
but be encapsulated so that it does not react with any parts of the body then this
problem could potentially be eliminated[4].
Ultra short carbon nanotubes allow for gadolinium to be present in the
area of the body being imaged, without exposing the ion directly to anything else
in the body. Carbon nanotubes are a cylinder-shaped nano-material, which is
made of carbon [9]. They have a lot of kinds of structures, length, thickness, and
number of layers [9]. Carbon nanotubes usually have up to 50 nm diameters [10].
Their lengths are typically several microns, but recently they can be made much
longer, and measured in centimeters [10]. Carbon nanotube was highlighted from
when we could research and deal with carbon tubules in nano-meter dimensions
[9].
Carbon nanotubes are usually produced by three methods: arc-
discharge, laser ablation, and chemical vapor deposition [10]. Among three
methods, the last one is the most widely used commercial method to prepare
carbon nanotubes [10]. This process generally involves reaction of a metal
catalyst with a hydrocarbon at very high temperatures to produce carbon
nanotube [10]. Nanotubes, which are made by chemical vapor deposition,
commonly have metal catalysts on the surface of outside of the nanotube [10].
Because metal catalysts, typically nickel can be used to make carbon nanotubes
bigger, there can be a problem with carbon nanotubes being cytotoxic [10].
Therefore a purification step is highly required before we can use carbon
nanotubes for biomedical applications [10].
There are also several methods for purifying carbon nanotubes [10]. The
most popular method is refluxing carbon nanotubes in an oxidizing acid such as
nitric acid [10]. This process includes oxidizing and removing the metal catalysts
from both the inside and outside of the tube [10]. Besides, any defects in the tube
can also be oxidized while it makes additional groups of carboxylic acids along
the tube [10]. These carboxylic acid groups can be more functionalized allowing
tuning of the surface chemistry of the nanotube [10].
Carbon nanotubes become popular for biomedical applications because
of its composition, high aspect ratio and properties [10]. The number of articles
about it has been doubling each year since the year 2000 [10].
Design Criteria
In the invention of Shortened Carbon Nanotubes in [21] by Wilson and
Bolskar, they illustrate a carbon nanotube of a distance end to end in range from
20 nm to 50 nm [21], and containing gadolinium as a contrast agent [21], which is
able to significantly improve the level of detail in the MRI, therefore increasing its
image quality [21]. In fact, we want to expand the relaxivity [11], known as the
variation of the proton’s relaxation rate divided by its particular molarity, and the
standard units are mM^-1*s^-1 [11].
In order for this specific invention [21] to work perfectly, we have several
special conditions in [21] which will further be discussed here.
The design in [21] includes a carbon nanotube, meaning a category of
fullerene, containing an extended cylinder that is composed of 5 and 6
components in each ring [21]. There can be single walled carbon nanotubes,
which include only one cylinder around an axis [21], and there can also be multi-
walled carbon nanotubes, which enclose two or more than two cylinder of
carbons around a specific axis [21]. Moreover, their sizes might vary, and so the
ideal carbon nanotubes for the invention in [21] will be a single walled carbon
nanotube and in the range of 20 nm to 50 nm [21].
There is a big difference between both single walled and multi walled
shortened carbon nanotubes [21]. In this paper the main focus is on single walled
carbon nanotubes [21]. Carbon nanotubes are all composed of folding graphite
layers into carbon cylinders which can form single layers or multiple layers [20].
Single walled carbon nanotubes are the best choice for bio imaging in such
circumstances as an MRI [20]. This is because in general, single walled have a
smaller diameter then multi walled nanotubes [20]. The first big issue with multi
walled carbon nanotubes is that it is more difficult to fill them with contrast agents
[20]. Transport of the contrast agent into the nanotubes is reliant on holes
opening in the tubes at high temperatures [19]. There is little to no open gates
(holes) in multi walled carbon nanotubes since there is not much change in
voltage at the walls [20]. This being said it is much harder for contrast agents
such as gadolinium to permeate the nanotube [20]. The opposite is true for single
walled carbon nanotubes which are much more permeable under the same
conditions [20]. Single walled nanotubes have a much higher conductance at the
walls when heated, which provides a higher carrying density and ability to
transfer through holes in the walls [20]. The second big issue with multi walled
carbon nanotubes is that they will have much more trouble showing up in bio-
imaging then single walled [20]. This lowers resolution in imaging because of the
thicker diameter of the walls, and the fact that there is a low open gate effect so
electrons are not detected as easily from the outside of the nanotube [20].
Actually, multi walled carbon nanotubes throw off the ability to see the contrast
agents within since they have a larger electronic structure themselves [20].
In addition, single walled carbon nanotubes or SWNTs, have special
properties that fit perfectly in several biomedical purposes [11], especially carbon
nanotubes with sizes from 20 nm to 100 nm [11], are excellent when it comes to
its expulsion from the organism [11]. Also, shortened carbon nanotubes could be
preferred for biocompatibility objectives [11], because the outside of the SWNT
can be used to easily add chemical compounds to increase its tendency to
dissolve [11]. Moreover, the inside of the SWNT might be appropriate to place
harmful agents such as gadolinium, and so the toxicity would be enclosed by the
surroundings of the SWNT [11]. These are tremendously important criteria in the
invention [21] by Wilson and Bolskar.
It can be demonstrated that SWNTs having a size from 20 nm to 50 nm,
considerably enlarge the analyzed surface area in [12], and radically reduce the
velocity of discharge of particles [12]. In the study described in [12], short SWNTs
were put side by side with SWNTs that were not divided into the described
length, charcoal and some additional carbon substances that did not illustrate
better characteristics than the ones explained by SWNTs [12]. So because of
these characteristics, the mentioned SWNTs can be implemented in the medical
field to release radionuclide molecules [12]. In addition, the SWNTs were divided
using the practice of fluorination and pyrolysis [12, 21]. In this particular case,
fluorination was done at 100 °C for a time of 2 hours, and at a 1/100 proportion of
F2 in He [12], and to separate the SWNTs, pyrolysis was performed using argon
for 1 hour at 1000 °C [12]. This method is also referred as fluorination-cutting
process, which is also used in the invention in [21] by Wilson and Bolskar.
Once the shortened carbon nanotube has been cut, then we can place a
contrast agent inside the SWNT [21]. This can be done by creating a spread
nanocapsule suspension into water by intense mixing and sonication for 60
minutes at 30 W [21].
In order to understand how the different types of contrast agents behave,
a discussion of the way MRI works is presented. In the MRI, the image quality is
a consequence of the contact between the protons found in the water molecules
and the contrast agents [13]. If a magnetic field is directed through the protons,
their spins become organized in a way perpendicular or in the direction of the
magnetic field [13], and as a result, their spins change to the Larmor frequency
[13]. The process continues by sending a radio-frequency pulse (or RF pulse) as
described in [13], and due to this stimulus, the protons acquire energy and now
change their orientations are in the same direction as this RF pulse [13]. When
the RF pulse is eliminated, protons come back to their initial position [13], and we
can categorize the time taken from the RF pulse to their initial position as T1 or
longitudinal relaxation time, and T2 or transverse relaxation time [13]. This is the
reason contrast agents can also be divided into T1 contrast agents and T2
contrast agents [13, 14], and one of the main tasks of any contrast agent, not
matter if it is a T1 or T2 contrast agents, will be to decrease its relaxation time
[13, 14].
So let us compare T1 and T2 contrast agents. T1 contrast agents are for
the most part paramagnetic molecules [13, 14], and this is because they contain
metals which comprise electrons that are not paired, and as a result, they create
a magnetic moment [14]. Some examples of paramagnetic contrast agents are
manganese, copper, gadolinium and chromium [13 Fig 3(cited in 14)]. On the
other hand, T2 contrast agents include particles in the nanoscale from iron oxide
[13, 14], which are a type of super paramagnetic agents [14].
Although T2 contrast agents from iron oxide have been used significantly
for the past 2 decades [13], they have major difficulties that are preventing them
to desirable contrast agents [13]. These inconveniences include the fact that
these T2 agents are negative imaging agents [13], which means that they
diminish the signal result and resolution, displaying a dim and unclear image that
could be leading to observe diseases in a certain way, where in fact the patient
has a totally different disease [13]. In addition, they have elevated vulnerability,
causing a deformation in the magnetic field of the nearby tissue [13], which also
contributes to make the signal difficult to see and it completely ruins the
surroundings of injury images [13]. On the other hand, T1 contrast agents work in
the opposite way because they are positive imaging agents [13]. This means that
they tend to produce a luminous and resplendent signal that improves the image
quality, leading to the right interpretation of diseases [13]. Moreover, T1 contrast
agents provide a greater spatial resolution, and because they are paramagnetic,
they do not cause the deformation of the constant magnetic properties in
extended magnitudes [13], giving excellent contrast in the surroundings of
anatomic images [13].
Now that we have seen why T1 contrast agents are preferred over T2
contrast agents, let’s examine some of the T1 contrast agents that might be
appropriate for the design in [21]. For example manganese is one of the contrast
agents that can be used in MRI [14, 15]. The total number of unpaired electrons
in Manganese is 5 [15] and it is mainly implemented in animal analysis using
functional MR techniques [15]. An advantage that manganese has is that it
promotes its own stability in the environment [15], but one of its major
disadvantages is the inexistence of compatible molecules that can attach to the
ions of manganese, and the same time, create a stronger adhesion than
molecules derived from manganese itself [15(cited in 14)]. Thus, because
manganese is a poisonous ion [15(cited in 14)], before it can be considered as a
strong contrast agent candidate, it is necessary to discover ways to send it to the
desired location in the body [14], and send it in small amounts, while verifying
that the MRI is able to notice its presence in such amounts [14]. In addition,
manganese has a magnetic moment of 5.92 [13 Fig 3(cited in 14)], but if we
compare it to gadolinium, which has a magnetic moment of 7.94 [13 Fig 3(cited in
14)], it can be concluded that gadolinium provides a somewhat better relaxation
enlargement characteristics than manganese [15]. So based on these facts, we
can recognize that gadolinium is a better candidate to be used as a contrast
agent than manganese.
As stated before, gadolinium is the perfect candidate for the invention in
[21] by Wilson and Bolskar. It is known that gadolinium ion is the best T1 contrast
agent [11], because the number of unpaired electrons that gadolinium encloses
is 7 [11, 13, 21], making gadolinium the only ion with the highest number of
electrons that are not paired [11]. Additionally, gadolinium does not only have an
incredible magnetic moment [11, 13, 21] of 7.94 [13 Fig 3(cited in 14)], but also it
has a relaxing ground state that is not quick, and extremely balanced [11], so it
creates high strength fluctuations close to the Larmor frequency of the protons in
hydrogen, and consequently generating a solid T1 signal [11]. Another
advantage that gadolinium has is that it is very accessible [14].
Furthermore, in [11] and [21], Nuclear Magnetic Relaxation Dispersion or
NMRD is displayed [11 Fig 1, 21 Fig 1]. In this study, the relaxivity of shortened
SWNTs filled with ions of gadolinium, at 37 °C in a solution of 1% sodium
dodecyl benzene sulfate [11, 21] was graphed versus the magnetic field [11, 21].
The concentration for gadolinium was 0.044 mM [11 Fig 1, 21 Table 2]. A
medical contrast agent employed now in MRI is [Gd(DTPA)(H2O)]2- and was also
graphed [11, 21]. It can be seen that the shortened SWNTs containing
Gadolinium ions illustrate a relaxivity equal to 170 mM^-1*s^-1 [11, 21], which is
approximately 40 times bigger [11, 21] than the medical contrast agent which
was 4.0 mM^-1*s^-1 [11, 21]. This was done at a typical power of the MRI field
for the medical visualization purposes from 20 MHz to 60 MHz [11, 21].
The filling of the gadolinium into the shortened carbon nanotubes is very
important [21]. The shortened carbon nanotubes have very high electrical
properties which provide for a good capsule like structure for contrast agents
during MRI’s [19]. Gadolinium is an excellent contrast agent and has a high
resolution inside the SCNT’s during an MRI [21]. The shortened single walled
carbon nanotubes are exposed to dry air at over 400 degrees Celsius [19]. This
hot air opens the ends of the nanotubes [19]. The gadolinium fused with either a
carbon or chloride group is then heated into a vapor and penetrates the nanotube
walls which are open from the heat [19]. The gadolinium then lines up inside the
nanotube and can be confirmed via electron microscopy [19]. The gadolinium
atoms then each transfer 3 electrons to the surrounding area of the SCNT,
creating a steeper electrical resistance vs. temperature curve [19]. This
introduction of the gadolinium into the shortened carbon nanotubes changes the
electrical properties of the nanotubes [19]. Consequently, this creates a much
better contrast during an MRI [19].
In order for carbon nanotubes to be safer they must be biocompatible [21].
It is very important to have biocompatibility with any form of a substance that is
being placed into the human body [6]. For something to be biocompatible it
means that the substance must blend in to the human body and not seem
strange [6]. A substance with little biocompatibility will have negative effects from
the cells in the body [6]. The human immune system will attack any foreign body
substance in order to protect the body [6]. For inserted substances for example,
they stimulate a specific swelling reaction or known as foreign body response [6],
which provokes protein intake, congregation of macrophages and neutrophils,
configuration of giant cells, and at the end, the engagement of endothelial cells
and fibroblasts [6]. However, if the body cannot sense the substance as a foreign
body, then it will not react [6]. This is why it is important to blend in, because
there will not be a negative response if there is high biocompatibility [6].
Biocompatibility is incredibly important when dealing with medical devices and
drugs [6]. The material must assimilate in order to do its job whether it is
something as small as a tiny drug, or as big as a pacemaker [6].
The biocompatibility of carbon nanotubes used for MRI’s must be very
good [21]. The body must allow the single walled nanotubes sealed with
gadolinium (contrast agent) [21] to flow through the body without having a foreign
body response [4]. It is also important that the gadolinium does not leak out of
the nanotubes since it is known to be toxic [4]. The key biocompatibility
components are to make sure the nanotubes are sealed properly, shortened, and
coated in order to mask the fact that they are foreign [21].
It is very important to properly seal carbon nanotubes in order for them to
be effective inside the human body [21]. If the contents of the nanotube were to
leak out inside the body there could be cell and tissue damage [21]. This is why it
is vital that they do not have any holes, and are filled properly [21]. In this case
gadolinium is the contrast agent that is put into the shortened carbon nanotubes
[21]. This metal can be combined with chloride (Cl3) which forms gadolinium tri-
chloride, and makes a very good contrast agent [16]. It is important to have this
combination because the nanotubes must be filled properly and the walls of the
nanotube must be free of defects [16]. The combination of this metal and
chloride nanowires line the inside of the carbon nanotube and decrease the
diameter of the walls [16]. This overall strengthens the walls of the carbon
nanotube and minimizes leakage [16]. There are many different metal nanowires
that that can fill a carbon nanotube, but in this case the focus is on gadolinium
(III) chloride [16]. It is shown that this metal chloride has very defined nanowires
which can be seen through transmission electron microscopy [16].
As previously talked about in the background section of the paper, the
Gadolinium must not get out of the carbon nanotubes [4]. It is a very toxic
substance and does not get along well with the human body [4]. It causes
problem in the kidney, and especially effects people with acute or chronic severe
kidney insufficiency or kidney dysfunction [4]. In some cases it causes NSF
(nephrogenic systemic fibrosis) which causes fibrosis of the skin and connective
tissue [4]. This is just one example of how toxic gadolinium is in the human body.
It is crucial that the SCNT’s are sealed properly and coated so that the human
body does not attack the nanotubes [21]. The goal is to use the gadolinium as a
contrast agent during MRI and then for the body to dispose of it without any harm
[21].
After the sealing process of shortened carbon nanotubes, it is important to
make sure the shortened carbon nanotube will assimilate into the body [21]. The
key factor in making an effective SCNT is to make sure it is very soluble [17].
This is called derivatization, or the coating of the carbon nanotubes to help blend
in [17]. The main way to increasing solubility is with increased bond formation
with carboxylic groups [17]. The big problem is that SCNT’s are very insoluble to
begin with; however they exhibit strong mechanical and electronic properties
[17]. This means that they are open to chemical modifications to the exterior in
particular [17]. SCNT’s are generally wrapped in polymers in order to help
increase the solubility [17]. This increase is very important because once placed
into the body the carbon nanotubes need to perform their imaging task safely and
efficiently [21]. Using mainly 1, 3 dipolar cycloaddition polymers the
functionalization of the nanotubes greatly increased [17]. These polymers create
a very high solubility in water which is perfect for MRI imaging since majority of
the human body is composed of water and is all based in an aqueous
environment [17].
The shortened carbon nanotubes must safely carry the contrast agent and
not harm any cells they come around [4]. Using carbon scaffolding with
carboxylic chains, and phospholipid like structures to the outside of the SCNTs
the biocompatibility inside the human body increases [18]. Through using a wet-
chemical process, defects are created which introduces hydrophilic carboxylic
groups on the ends of the SCNTs [18]. These carboxylic groups react with the
chemicals in the human body [18] without any harmful effects [4]. Oxidized
SCNTs with covalently bonded carbon groups on the walls can also be coupled
with other types of structures such as alcoholic chains to increase solubility [18].
It is shown that by using the addition of carboxylic groups to the walls there is no
high toxicity level [18]. This method shows an efficient way to spread out SCNT’s
into a specific part of the body safely [18]. The carboxylic groups have simple
reactions with those of the human body and then exit soon after [18]. Single
walled shortened carbon nanotubes are great transporters for contrast agents (in
this case gadolinium), within the human body [18]. Consequently, SWCNT’s are
excellent for use in MRI’s based upon their properties, shape and structure [18].
The Design
The invention in [21] by Wilson and Bolskar describes how to make
shortened carbon nanotubes for use in MRI imaging [21]. Robert D Bolskar is a
researcher in the imaging field and a distinguished employee of TDA research
[22]. He has had several publications and many awards won over the course of
his career [22]. For example a well-known publication he co-wrote and won an
award for is the Improved Manufacturing Process for Advanced Imaging Agents
[22]. Lon J. Wilson is a professor of chemistry at Rice University and his research
revolves around incorporating carbon nanotechnology to other fields, namely,
biology and medicine [23]. One of his many publications is Nanotechnology and
MRI contrast enhancement [23].
This invention presents the methods and the advantages of the particular
processes used to make shortened carbon nanotubes [21]. The carbon nanotube
which is a long thin cylinder, for simplification and visualization purposes, will
serve as a net or cradle for the contrast agent that will be inserted inside the
hollow nanotube [21]. So for imaging, the purpose of the shortened carbon
nanotube is to carry magnetic material into the body [21]. A carbon nanotube is a
type of fullerene in the form of a hollow tube consisting of only carbon atoms in
pentagon and hexagon rings [21]. The shortened carbon nanotube has a
diameter of 1.2 nanometer diameter and each carbon ring of the single walled
carbon nanotube has a width of 2.83*10^-10 m, a height of 2.45*10^-10 m and
carbon bond lengths of 1.42*10^-10 m [24]. Also its density is 1.34 g/cm^3 and
its young’s modulus is 648.43 GPa [25]. Carbon nanotubes have lengths in the
order of hundreds of nanometers to a few microns [21]. So the shortened carbon
nanotubes in this invention simply refers to carbon nanotubes of reduced size, in
this case 50 nm would be a perfect size [21].
A long single walled-carbon nanotube of length 100 nm is the starting
material for this invention [21]. First the long carbon nanotube is cut into a
shortened carbon nanotube of about 50 nm by a process called fluorination-
cutting process [21,26]. The long carbon nanotube is reacted with a fluorinating
agent, fluorine [21,26]. This is done by heating the long carbon nanotube in a
fluorine atmosphere at 50°C for 2 hours [21]. The atmosphere is mainly a helium
atmosphere with 1% fluorine [21]. Fluorine atoms from the fluorine gas attach to
the outer or inner surface of the carbon nanotube [21, 26]. CF bonds are formed
in bands around the carbon nanotube [21]. The result is a fluorinated long carbon
nanotube [21, 26]. The following process is pyrolysis which consists of heating
the long fluorinated carbon nanotube at 1000°C for 4 hours in an argon
atmosphere [21, 26]. The heating is done in a quartz tube furnace which is a
temperature programmable heating device [21]. During pyrolysis, the long carbon
nanotubes are cut into short carbon nanotubes along the bands of CF bonds
[21]. CF bonds that did not form in bands but rather in spots in the presence of
fluorine gas, are responsible for the formation of holes in the carbon nanotube as
they volatilize under very high temperature [21]. This formation of holes accounts
for the side wall defects on the shortened carbon nanotube [21]. For purification,
the carbon nanotubes are exposed to high vacuum to remove any still remaining
traces of gases on the carbon nanotube [21]. CF4 and traces of COF2 and CO2
which were generated during pyrolysis are removed [21]. The fluorination cutting
process also involves the removal of residues of yttrium and nickel catalyst
particles that were initially present with the long carbon nanotubes [21]. Y/Ni
(yttrium/nickel) were added as catalysts during the electric arc discharge process
to produce the long carbon nanotubes [21]. The aim here is to have a carbon
nanotube at about 98% free of Y/Ni particles by aqueous acid extraction [21].
This is essential because remaining traces of metal catalysts would interfere with
the magnetic properties of the contrast agent [21].
Following the fluorination cutting process and pyrolysis, gadolinium ion
Gd3+ is inserted as a cargo inside the shortened carbon nanotube [21]. The
loading of the cargo is done by stirring 100 mg of shortened carbon nanotubes
and 100 mg of anhydrous GdCl3 in deionized water at pH 7 which was purified by
high performance liquid chromatography (HPLC) [21]. For better loading,
nanocapsule suspensions are immersed in an ultrasonic bath at 30 W for 60
minutes [21]. The solution obtained after sonication is then centrifuged to collect
the Gd3+ filled short carbon nanotubes which form the pellet [21]. The loaded
short carbon nanotubes form in clumps and the supernatant is then decanted
[21]. The pellet is washed with 25 ml of deionized HPLC grade water and
sonicated in the same manner described previously to remove any traces of
unabsorbed GdCl3 [21]. Again the filled short carbon nanotubes form in the pellet
and the supernatant is decanted [21]. This process is repeated three times [21].
By ICP or inductively coupled plasma analysis, the amount of Gd3+ in the carbon
nanotubes is determined [21]. The mass of the gadolinium loading was
determined to be 2.84% of the total mass of the nanocapsule [21]. The loading of
the contrast agent occurs through the open ends of the short carbon nanotube
but can also happen through the side wall defects [21]. We know that gadolinium
is a toxic substance for the human body [21]. So the presence of side wall
defects can be problematic because if the contrast agent can get in through
those holes then it can also get out [21]. Hence the better carbon nanotube is
one that has the least amount of side wall defects possible [21]. By electron
microscopy, the presence of sidewall defects can be detected [21]. The side wall
defects formation however, cannot be controlled during the fluorination cutting
process [21]. The short carbon nanotubes that have the least amount of holes
will be chosen for further modification [21]. The leakiness of the short carbon
nanotubes is determined by measuring the relaxivity of a solution containing the
filled nanocapsules (filled short carbon nanotubes) using NMR (nuclear magnetic
resonance) [21]. In solution, if free Gd3+ ions leak from the filled short carbon
nanotube then the gadolinium will have a significant effect on the relaxivity of
water protons in the supernatant [21]. If the relaxivity values of the supernatant
decrease after addition of TTHA6- ,then we can confirm that free gadolinium ions
are present in the supernatant because the [GdTTHA]3- complex, which forms
between Gd3+ and the ligand TTHA6-, has a significantly lower relaxivity value
than that of free aqueous Gd3+ ions alone [21].
To measure the relaxivity of the Gd3+ nanocapsules, two solutions are
prepared [21]. The first solution is a saturated solution of 40 mg of the Gd3+ filled
short carbon nanotubes in 20 mL of a 1% SDBS (sodium dodecyl benzene
sulfate) aqueous solution [21]. The second solution contains 10 mg of the Gd3+
filled short carbon nanotubes in 5 mL of a 1% solution of a biologically
compatible pluronic F98 surfactant [21]. After centrifugation, only 10% of the Gd3+
filled short carbon nanotubes, in both solutions, formed a stable suspension [21].
These suspensions present in the supernatant were used for the relaxivity
measurements [21]. The negative controls were Gd3+ filled short carbon
nanotubes suspensions at 40°C and 60 MHz using NMR [21]. The proton
relaxivities of the solutions at 60 MHz and 40°C were measured before and after
the addition of TTHA6- at pH=7 [21]. TTHA6- and Gd3+ form a very stable
complex, [GdTTHA]3- which has no inner-sphere water molecules and thus a
lower relaxitivity compared to aquated Gd3+ ions [21]. The relaxivity
measurements for both solutions however, show that the relaxivities are the
same with and without TTHA6- [21]. This confirms the absence of free Gd3+ ions in
the supernatant, meaning that the gadolinium content does not leak from the
short carbon nanotubes [21]. This is a satisfactory result for this invention since
we do not want the toxic gadolinium to leak from the carbon nanotubes [21]. The
longitudinal relaxation rates (R1) were determined by the inversion recovery
method at pH=7 for the Gd3+ filled shortened carbon nanotubes in the 1% SDBS
surfactant solution and in the 1% pluronic F98 surfactant solution using NMR at
60 MHz [21]. The longitudinal relaxivity (r1) values were obtained from the
equation (T1-1)obs= (T1
-1)d +r1 [Gd3+] in which Tlobs is the relaxation time in
seconds of the Gd3+ filled shortened carbon nanotubes and T1d, the relaxation
time in seconds of the aqueous surfactant solutions [21].
Another test was undertaken to determine the content of the cargo, in
other words, to determine if any traces chemical compounds are present other
than gadolinium ions [21]. First, the 1% SDBS surfactant and the 1% pluronic
F98 surfactant solutions containing Gd3+ filled shortened carbon nanotubes were
treated with a 90% HNO3 (nitric acid) solution and then heated at very high
temperature (specific temperature not mentioned in the invention) until a solid
residue forms [21]. For clarification, all the aqueous solution evaporates [21].
Then, the solid residue is treated with a 30% H2O2 solution and heated again until
all the remaining carbon material, in other words the carbon nanotube structures,
are eliminated [21]. The remaining solid residue is dissolved in 2% HNO3 and
analyzed by ICP [21]. The chemical analysis of this solid residue is done by an
inductively coupled plasma atomic emission spectrometer with a CCD detector
[21]. For each of the two samples from our two solutions, seven scans were done
[21]. In this analysis each chemical is associated to a wavelength [21]. The
gadolinium line was at λ= 376.84 nm [21]. The intensity of the light is associated
with the amount of a chemical [21]. As we can expect the gadolinium line had the
highest intensity because it is the chemical present in the highest concentration
[21]. The line at λ= 361.38 nm indicates the presence of another chemical [21].
Other than gadolinium, Ni or Nickel mentioned earlier was found to be present in
low concentrations from 0.1 to 0.05 ppm (parts per million) as impurity [21]. The
other metal catalyst Y, yttrium was not detected, at least not within the range of
the device which lower limit is 1 ppb (part per billion) [21].
The damaged areas of the tubes have exposed and dangling bonds that are
subject to oxidation by the environment, which cause the bonding of hydroxyl,
carbonyl and carboxyl groups at the end of the nanotubes [27]. These reactions
and bonds of carboxyl groups have been exploited to cause derivatization
(functionalizing) of carbon nanotube and will be discussed further on [27]. These
defects are unwanted and a pristine tube is what is needed to continue on with
the process [21]. After the shortened single walled carbon nanotube has been
examined and deemed acceptable both ends of the tube must be closed [21],
caps are formed and attached to the ends of the tubes with a simple, reliable and
effective technique [28]. Fullerendion opens due to thermal oxidation and causes
hemispherical caps which start single walled carbon nanotube growth at their
open ends [28]. The size and shape of the caps adjusted to the desired
specifications by using specific temperatures of thermal oxidation [28].
After both ends are capped the shortened single walled carbon nanotubes
are derivatized by forming bonds with carboxylic groups to increase solubility in
water, biocompatibility, to lower their toxicity and so on[29]. So to help improve
the chemical and physical interactions with the body the shortened single walled
carbon nanotubes are derivatized. If un-derivatized, the surface of the shortened
single walled carbon nanotubes is inert chemically and as such it is incompatible
with almost all organic and inorganic solvents, which in turn makes them less
adaptable for future uses and applications [29]. So in short the the overarching
goal for the single walled carbon nanotubes is to increase their solubility in water,
make them more biocompatible, and decrease the toxic effects [29].
The shortened single walled carbon nanotubes can be derivatized by bonding
oligonucleotides, biomolecules, surfactants, and polymers functional groups [29].
It has been reported that after being functionalized, the derivatized single wall
carbon nanotubes solubility increased dramatically; and several studies
have also shown that with increased solubility (or dispersion), the performance of
derivatized single walled carbon nanotubes increases as well as lowers their
toxicity [29]. The derivatized single walled carbon nanotubes also have fantastic
electro-optical properties, high tensile strength, and a high surface-area-to-
volume ratio that also allows for surface derivatization [29].
Other report have also shown that the highly water-soluble derivatized single
walled carbon nanotubes have been absorbed into the cells without any bodily
response [29]. This proves that derivatized shortened single walled carbon
nanotubes are much more biocompatible with physiological systems and as such
much less toxic [29]. With this in mind it is entirely possible to use these
derivatized shortened single walled carbon nanotubes to infiltrate cells without ill
effects, and as such would be perfect to use as trackers or payloads for delivery
to very specific locations [29]. All in all the derivation of the shortened single
walled carbon nanotubes makes them safer and more effective in interacting
with the body and as such easier to be delivered and used as the contrast agent
to the MRI [29].
Shortened carbon nanotubes have several medical applications [11]. They
can be used for imaging of a specific tissue by adding a specific coating on the
surface of the shortened carbon nanotubes consisting of antibodies to target
specific tissues [30]. Single walled carbon nanotubes can also be used to treat
cancer, such as breast cancer [30]. A modified single shortened carbon nanotube
is functionalized for tissue targeting and is filled with an anticancer drug
doxorubicin that is released once the carbon nanotube enters the cancerous cells
[30].
We can improve the invention in [21] on several levels to use for treating
breast cancer [30]. In invention in [30], shortened carbon nanotubes are coated
with polysaccharides, sodium alginate (ALG) and chitosan (CHI) [30]. The
modified short single wall carbon nanotube contains doxorubicin as a cargo,
which is an anticancer drug [30]. The DOX-CHI/ALG-SWCNT includes folic acid
(FA) on its surface as a targeting group for cancerous tissue [30]. The
polysaccharides ALG and CHI are used because of the increased
biocompatibility they confer to the carbon nanotubes [30]. The modified single
wall carbon nanotubes obtained have an improved ability to accumulate in
specific cancerous tissue and to release the toxic doxorubicin in a controlled
manner [30].
To prepare the ALG-SWCNTs, 20 mg of the shortened carbon nanotubes
are sonicated in a sodium ALG solution for 20 minutes [30]. The sodium ALG
solution is made from 40 mg of sodium alginate in 40 ml of 0.1M aqueous NaCl
[30]. After sonication, the solution is stirred for 16 hours at room temperature
[30]. The modified carbon nanotubes obtained are then collected and purified by
ultracentrifugation using ultrapure water [30]. The goal of this purification process
is to remove any unbound ALG [30]. The modified carbon nanotubes are finally
dried at room temperature to obtain the ALG-SWCNTs [30]. Next, 10 mg of ALG-
SWCNTs are sonicated for 20 minutes [30]. Then a 20 ml CHI solution made of
20 mg of chitosan in 0.1M aqueous NaCl and 0.02M acetic acid is added to the
ALG-SWCNTs [30]. The ALG-SWCNTs and CHI solution are stirred at room
temperature for 16 hours [30]. Then after ultracentrifugation, purification and
drying, we obtain CHI/ALG-SWCNTs [30]. Afterwards, 4 mg of CHI/ALG-
SWCNTs are suspended with 6 mg of FA (folic acid) in an 8 ml pH 7.4 PBS
buffer solution [30]. 5mg of EDC.HCl is then added and the mixture is stirred at
room temperature for 16 hours [30]. Following the same steps as described
above we obtain FA-CHI/ALG-SWCNTs [30].
Finally to load the doxorubicin into the carbon nanotubes, 9 mg of DOX
hydrochloride is stirred with 3 mg of FA-CHI/ALG-SWCNTs dispersed in 6 ml of
PBS buffered solution of pH 7.4 at room temperature for 16 hours [30]. Following
the same steps the final functional modified single wall carbon nanotubes is
obtain and can be used to deliver the drug [30].
Shortened Carbon Nanotubes
References
[1] American Cancer Society, the history of cancer [Internet] 6/8/12 , available
from http://www.cancer.org/cancer/cancerbasics/thehistoryofcancer/index
[2] Winship Cancer Institute, Emory University The History of Cancer Detection
[internet] 9/4/2010, Available from
http://www.cancerquest.org/history-cancer-detection.html
[3]Web Elements, Essential information on Gadolinium, [Internet] 2012 available
from: http://www.webelements.com/gadolinium/
[4]U.S. Department of Health and Human Services, FDA Drug Safety Newsletter
on Gadolinium-Based Contrast Agents [Internet] 8/26/2013 Available from
http://www.fda.gov/Drugs/DrugSafety/DrugSafetyNewsletter/ucm142889.htm
[5] Tzarachan, Najarian, Brockway, Breast cancer detection in gadolinium-
enhanced MR images by static region descriptors and neural networks.
University of North Carolina-Charlotte [Internet] 3/17/2003 Available from
http://www.ncbi.nlm.nih.gov/pubmed/12594724
[6] W. Mark Saltzman, Biomedical Engineering, 32 Avenue of the Americas (NY),
Cambridge University Press, 2009
[7] David J. Brenner, Eric J. Hall, Computed Tomography — An Increasing
Source of Radiation Exposure, The New England Journal of Medicine, 2007
[8] Kenneth N. Raymond, Valerie C. Pierre, Next Generation, High Relaxivity
Gadolinium MRI Agents, Bioconjugate Chem, 2005
[9] M. S. Dresselhaus, G. Dresselhaus, R. Saito, Physics of Carbon Nanotube,
Elsevier Science Ltd, 1995
[10] Benjamin S. Harrison, Anthony Atlata, Carbon nanotube applications for
tissue engineering, Biomaterials, 2007
[11] Sitharaman B, Wilson LJ. Gadonanotubes as new high-performance MRI
contrast agents. Int J Nanomedicine [Internet]. 2006 [cited 28 Nov
2013];1(3):291–295. Available
from:http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2426797/pdf/nano-0103-
291.pdf
[12] Mackeyev YA, Marks JW, Rosenblum MG, Wilson LJ. Stable containment of
radionuclides on the nanoscale by cut single-wall carbon nanotubes. J Phys
Chem B [Internet]. 2005 Mar 5 [cited 28 Nov 2013];109(12):5482–5484. Available
from: http://pubs.acs.org/doi/pdf/10.1021/jp0456436
[13] Na HB, Song IC, Hyeon T. Inorganic nanoparticles for MRI contrast agents.
Adv Mater [Internet]. 2009 Mar 4 [cited 28 Nov 2013];21(21):2133–2148.
Available from: http://onlinelibrary.wiley.com/doi/10.1002/adma.200802366/pdf
[14] Shokrollahi H. Contrast agents for MRI. Mater Sci and Eng: C [Internet].
2013 Jul 18 [cited 28 Nov 2013];33(8):4485-4497. Available from:
http://dx.doi.org/10.1016/j.msec.2013.07.012[15] Terreno E, Castelli DD, Viale A, Aime S. Challenges for molecular magnetic
resonance imaging. Chem Rev [Internet]. 2010 Apr 23 [cited 28 Nov
2013];110(5):3019-3042. Available from:
http://pubs.acs.org/doi/pdf/10.1021/cr100025t
[16] Chikkannanavar S, Taubert A, Luzzi D. Filling single walled carbon
nanotubes with metal chloride and metal nanowires and imaging with scanning
transmission electron microscopy. University of Pennsylvania [Internet]. 2001
Nov 26 [cited 28 Nov 2013]. Available from:
http://repository.upenn.edu/cgi/viewcontent.cgi?
article=1022&context=mse_papers
[17] Georgakilas V, Kordatos K, Prato M, Guldi D, Holzinger M, Hirsch A.
Organic Functionalization of Carbon Nanotubes. J. AM. Chem Soc [Internet].
2002 Jan 8 [cited 28 Nov 2013]. Available from:
http://pubs.acs.org/doi/abs/10.1021/ja016954m
[18] De Santi M, Antonelli A, Meotta M, Sfara C, Serafini S, Lucarini S, Brandi G,
Magnani M. Single walled carbon nanotubes functionalization for the delivery of
the water insoluble anticancer agent indole-3-carbinol cyclic tetrameric derivative
CTet. Journal of Nanopharmaceutics & drug del. [Internet]. 2013 Jul 12 [cited
28 Nov 2013]. Available from:
http://www.researchgate.net/publication/236143056_Single-
Walled_Carbon_Nanotubes_Functionalization_for_the_Delivery_of_the_Water_I
nsoluble_Anticancer_Agent_Indole-3-
carbinol_Cyclic_Tetrameric_Derivative_CTet
[19] Hirahara K, Suenaga K, Bandow S, Kato H, Okazaki T, Shinohara H, Lijima
S. One-dimensional metallofullerene crystal generated inside single walled
carbon nanotubes. Phys Rev Lett [Internet]. 2000 Dec 18 [cited 28 Nov 2013].
Available from: http://prl.aps.org/abstract/PRL/v85/i25/p5384_1
[20] Martel R, Schmidt T, Shea H, Hertel T, Avouris Ph. Single- and multi- wall
carbon nanotube field-effect transistors. App Phys Lett [Internet]. 1998 Aug 24
[cited 28 Nov 2013]. Available from:
http://scitation.aip.org/content/aip/journal/apl/73/17/10.1063/1.122477
[21] Wilson LJ, Bolskar RD, inventors; Shortened carbon nanotubes. US patent
application 20080003182. 2008 Jan 3. 15 p. Available from:
https://docs.google.com/a/stonybrook.edu/viewer?
url=patentimages.storage.googleapis.com/pdfs/US20080003182.pdf
[22] Margrave JL, Gu Z, Hauge RH, Smalley RE, inventors; William Marsh Rice
University, assignee. Method for cutting single-wall carbon nanotubes through
fluorination. US patent application 20040009114. 2004 Jan 15. 16 p. Available
from: https://docs.google.com/a/stonybrook.edu/viewer?
url=patentimages.storage.googleapis.com/pdfs/US20040009114.pdf
[23] Zhang X, Meng L, Lu Q, Fei Z, Dyson PJ. Targeted delivery and controlled
release of doxorubicin to cancer cells using modified single wall carbon
nanotubes. Biomaterials [internet]. 2009 Oct [cited 28 Nov 2013]; 30(30):6041-7.
Available from:
http://www.sciencedirect.com/science/article/pii/S0142961209007455
[24] Spires T, Brown RM Jr. High resolution TEM observations of single-walled
carbon nanotubes [Internet]. Department of Botany, The University of Texas at
Austin; 1996 Aug 14 [cited 2013 Dec 1]. Available from:
http://www.botany.utexas.edu/facstaff/facpages/mbrown/ongres/tspires/nano.htm
[25] Sitharaman B, Kissell KR, Hartman KB, Tran LA, Baikalov A, Rusakova I,
Sun Y, Khant HA, Ludtke SJ, Chiu W. Superparamagnetic gadonanotubes are
high-performance MRI contrast agents. Chem Commun [Internet]. 2005 [cited
2013 Dec 1] ;21:3915–3917. Available from:
http://pubs.rsc.org/en/content/articlepdf/2005/cc/b504435a
[26] Gao G, Cagin T, Goddard III WA. Energetics, structure, mechanical and
vibrational properties of single-walled carbon nanotubes. Nanotechnology
[internet]. 1998 [cited 28 Nov 2013]; 9(3):184-191. Available from:
http://authors.library.caltech.edu/521/1/GAOnanotech98.pdf
[27] Carbon nanotubes [Internet]. Department of Physics, Texas Tech University; [cited 2013 Dec 1]. Available from: http://www.phys.ttu.edu/~tlmde/thesis/CARBON_NANOTUBES.html
[28] Yu X, Zhang J, Choi WM, Choi YC, K JM, Gan L, Liu Z. Cap formation
engineering; from opened C60 to single-walled carbon nanotubes [internet].
Fullerenes: advances in research and application; 2011edition [Cited 2013 Nov
27]. Available from http://pubs.acs.org/doi/abs/10.1021/nl101017
[29] Vardharajula S, Ali SZ, Tiwari PM, Eroglu E, Vig K, Dennis VA, Singh SR.
Functionalized carbon nanotubes: biomedical applications [internet]. International
journal of nanomedicine; 2012 Oct 9 [Cited 2013 Nov 29]. Available from
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3471599/
Picture references for schematic drawings:
[30] Zhang X, Meng L, Lu Q, Fei Z, Dyson PJ. Targeted delivery and controlled
release of doxorubicin to cancer cells using modified single wall carbon
nanotubes. Biomaterials [internet]. 2009 Oct [cited 28 Nov 2013]; 30(30):6041-7.
Available from:
http://www.sciencedirect.com/science/article/pii/S0142961209007455
Picture references for schematic drawings:
[31] Sitharaman B, Kissell KR, Hartman KB, Tran LA, Baikalov A, Rusakova I,
Sun Y, Khant HA, Ludtke SJ, Chiu W. Superparamagnetic gadonanotubes are
high-performance MRI contrast agents. Chem Commun [Internet]. 2005 [cited
2013 Dec 1] ;21:3915–3917. Available from:
http://pubs.rsc.org/en/content/articlepdf/2005/cc/b504435a
[32] Carbon nanotubes [Internet]. Department of Physics, Texas Tech
University; [cited 2013 Dec 1]. Available from:
http://www.phys.ttu.edu/~tlmde/thesis/CARBON_NANOTUBES.html
[33] Sitharaman B, 9/18/2013 Nano based Molecular Imaging Lecture, BME 100