Control and Monitoring of Control and Monitoring of Hydrogen Sulfide in Digester Hydrogen Sulfide in Digester

Gas Gas

Steve Walker

Craig Barnes

Metro Wastewater Reclamation District

Page 2: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Metro District’s Central Treatment Plant

Page 3: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

What to Use to Control HWhat to Use to Control H22SS

• Equipment • Iron vs. Aluminum Salts

• Dewatering Issues

• 503 Regulations – Aluminum under scrutiny in Round 2

• Iron beneficial for crops and other plants

Page 4: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

District’s Reasons to Reduce District’s Reasons to Reduce the Amountthe Amount

• Potential offsite buyer for methane - gas contaminated with 3000 + ppm H2S

• Tried ferrous chloride from supplier’s recommendation

• Tried ferric chloride as an alternative

Page 5: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Reasons for AlternativesReasons for Alternatives

• Cost Comparison

• Flexibility

• Impacts on Processes

Page 6: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

ResultsResults

• Cost – active pounds/digester loading – Same

• Reaction time slower with ferrous

• Flexibility proven – could use either product

Page 7: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Addition Points ImpactsAddition Points Impacts

• Primary Influent• Ferrous• Ferric

• DAF Conditioning Box• Ferrous• Ferric

Page 8: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Use of Ferric After TestingUse of Ferric After Testing

• H2S impacts on cogeneration equipment• Equipment reliability

• Destruction of yellow metal parts

• Acidification of engine oil

• Struvite reduction

Page 9: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

12 cyl. Turbo 2000 hp w/1200 kW gen - 1 of 4

Page 10: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Engines required extensive maintenance

Page 11: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Trigen’s Turbine control panel with PLC

Page 12: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Trigen’s pride and joy - Centaur 40 Turbine

Page 13: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Current Usage and WhyCurrent Usage and Why

• Goal – Title V Air Permit Compliance• Limit of 169 tons per year SO2 to atmosphere

• H2S ceiling of 2000 ppm with running 3 hour average of 1800 ppm

• Ferric onsite – used for struvite control in dewatering process

• Handling one chemical vs. two - KISS

Page 14: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Current Dosing PointsCurrent Dosing Points

• Digester Feed Line

• DAF Conditioning Box

• NSEC Influent Channel

Page 15: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Ni/Deni Aeration Basin - 1 of 12

Page 16: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Current ResultsCurrent Results

• Gas production remains at 4MSCFD

• Holding H2S levels at 900 ppm +/- 100 with consistent feed rate

• Minimal Process Impacts• Foaming• Struvite

Page 17: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

NOTENOTE

• High flow in spring 2001 reduced sulfide generators in the collection system by flushing the piping. This made results seem better. Dosages are back to traditional levels now.

Page 18: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Dosage RateDosage Rate

• Roughly 0.3 gpm ferric solution to 650 gpm digester feed or……

• Roughly 2000 pounds/day to 340,000 pounds TS = 12 active lb/ton

• Digesters are fed sequentially so all get equivalent dose

Page 19: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

CalculationCalculation

• 0.3 gal/min x 8.34 lb/gal x 1.4 (specific gravity) x % iron in solution (40%) x 1440 min/day = 2000 lb/day of iron

• Lb/day x $0.10/lb x 365 days/yr = $73,000

Page 20: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Note the floating cover on Digester 6

Page 21: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

MonitoringMonitoring

• Effectiveness checked with GC Mass Spec – twice per week from grab sample

• This would not meet the requirements of the current air permit

• APCD permit required installation of Continuous Monitoring System (CMS)

Page 22: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Digester FlaresDigester Flares

Page 23: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Turbine ExhaustTurbine Exhaust

Page 24: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Continuous Monitoring Continuous Monitoring System (CMS) RequirementsSystem (CMS) Requirements

• Continuous gas stream H2S monitoring

• Continuous data transmission and recording

• Instrument reliability

• Relative Accuracy Test Audit (RATA) compliant

Page 25: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

LasIR UnitLasIR Unit

Page 26: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Control UnitControl Unit

Page 27: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Control Unit DisplayControl Unit Display

Page 28: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Modifications Needed After Modifications Needed After Initial InstallationInitial Installation

• Inability to meet accepted calibration protocol

• Extractive method required

• Water vapor in digester gas impacted reliability

Page 29: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

White Cell White Cell

Page 30: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

LasIR ReconfigurationLasIR Reconfiguration

• Sensor upgrade - aka “White Cell”

Page 31: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Gas Out(1/2” or ¼” Teflon tubing)

DiaphragmPump

Pressure/FlowController

To LasIR Analyzer

From LasIR AnalyzerFiber-optic cable

Coaxial cable

Infrared detector

Stack Gas IN(¼” or 1/8” Teflon tubing)

Cal. Gas IN

Three-way valve

Manual Valve

~ 15”

12-m multiple reflection (White) cell

Alak Chanda – 04January 2001

Layout of the Multi-pass Extractive Monitor Head

Page 32: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

LasIR UpgradesLasIR Upgrades

• Laser modified for extractive analysis

• Nitrogen gas used for purge and zeroing

• H2S calibration gas incorporated

Page 33: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Cal and Purge GasCal and Purge Gas

Page 34: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

ResultsResults

• Instrument has proven reliable

• Permit compliance achieved

Page 35: Control and Monitoring of Hydrogen Sulfide in Digester Gas Steve Walker Craig Barnes Metro Wastewater Reclamation District

Future UseFuture Use

• Instrument will control ferric dosing

• ANY QUESTIONS?