components required

21
COMPONENTS REQUIRED STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding

Upload: darby

Post on 20-Mar-2016

50 views

Category:

Documents


0 download

DESCRIPTION

COMPONENTS REQUIRED. STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding. Excitation Power Source. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: COMPONENTS REQUIRED

COMPONENTS REQUIRED

• STEP DOWN PRANSFORMER: Ac applied to primary winding can be stepped

down depending upon value of dc needed In our project 230v ac appear as 15v ac across secondary winding

Page 2: COMPONENTS REQUIRED

POWER SUPPLY UNIT

BLOCK DIAGRAM : +5 Volts +12 Volts -12 Volts

Step Down Transformer

Bridge Rectifier

Positive Charge Capacitor

Positive Voltage Regulator IC 7812

Negative Charge Capacitor

LPF

Negative Voltage Regulator IC 7912

LPF

+5V Regulator LPF

Page 3: COMPONENTS REQUIRED

PassiveTransducer

Excitation Power Source

+-

+-

0 to 100 % of physical impact

Output will be 0 if the Excitation is maximum for 0 to 100 % impact

Page 4: COMPONENTS REQUIRED

Signal Conditioner To ADC10

Ω

+4 - 20 m A -

Page 5: COMPONENTS REQUIRED

RECTIFIER UNIT

• Op-amp rectifier are used to convert ac to dc(IC LM 1458)CHARACTERISTICS OF OP-AMP It must be tunable It should not load pt and ct It should not have any conduction losses

Page 6: COMPONENTS REQUIRED

RELAYS

• Main function of relay is to detect the fault and intiate the operation of circuit breaker

ELECTROMAGNETIC RELAYS These relays acts as a switches which provides contact between two mechanical element

Page 7: COMPONENTS REQUIRED

INSTRUMENT TRANSFORMER

• CURRENT TRANSFORMER They are used so that ammeter and currents coils of instruments and relays need not be connected directly to high voltage line

Page 8: COMPONENTS REQUIRED

INSTRUMENT TRANSFORMER

• POTENTIAL TRANSFORMER High alternating voltage are reduced in a fixed proportion for the measurement purpose with help of potential transformer

Page 9: COMPONENTS REQUIRED

FILTERING UNIT

• It consists of capacitor acting as surge arrester

• To by pass ripples and high frequency signals

• It allows only low frequency signals

Page 10: COMPONENTS REQUIRED

VOLTAGE REGULATOR

• It helps rectifier and filter circuit in providing a constant dc voltage to device

Page 11: COMPONENTS REQUIRED

FIVE MODULES OF SCADA

• DATA ACQUIRING• DATA PROCESSING DATA CONVERSION• DATA MANIPULATION• DATA TRANSMISSION

Page 12: COMPONENTS REQUIRED

DATA ACQUIRING

• It acquires variable status like temperature pressure,flow etc components of data acquistion are from

simple thermocouple to complex gas analyser

Active transducer Passive transducer

Page 13: COMPONENTS REQUIRED

ACTIVE TRANSDUCER

• They are self generative as per physical variations offered to it

• ADVANTAGE Reliable low cost better inter changablity wide operating temperature

Page 14: COMPONENTS REQUIRED

PASSIVE TRANSDUCER

• These types of transducer have output will be full or partial of excitation

• ADVANTAGE available in all size DISADVANTAGE output will be reliable only if excitation source is reliable

Page 15: COMPONENTS REQUIRED

DATA ACQUIRING

• Flame detection• Intruder detection• Bomb detection• Cable fault detection• Staff attendance maintenance

Page 16: COMPONENTS REQUIRED

• FLAME DETECTION It can be used to detect fire in relays,

generator ,contacts with help of LDR INTRUDER DETECTION

Page 17: COMPONENTS REQUIRED

BOMB DETECTION

• SENSOR Inductive proximity sensor It can be used to detect even rdx bomb

Page 18: COMPONENTS REQUIRED

DATA PROCESSING

• It is much essential in field instrumentation for safe and secured operations of process industries

Page 19: COMPONENTS REQUIRED

DATA CONVERSION

• It is the process of converting analog into computing data

example of data converters are ADC and DAC

Page 20: COMPONENTS REQUIRED

DATA MANUPILATION

• It is the simple calculation between real value and ADC value

it comprises of • Recording of values • Graphical output• Indication • Controlling all application

Page 21: COMPONENTS REQUIRED

DATA TRANSMISSION

• It forms bridge between master control room and sub system area

• Radio frequency can be utilized for data communication