clean room technology

33
Clean room technology

Upload: taliya-hemanth

Post on 06-Aug-2015

77 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: Clean room technology

Clean room technology

Page 2: Clean room technology

Outline

• Introduction• Importance• Methods• Filters• conclusion

Page 3: Clean room technology

Definition

• A room in which the concentration of airborne particles is controlled, and which is constructed and used in a manner to minimize the introduction, generation, and retention of particles inside the room and in which other relevant parameters, e.g. temperature, humidity, and pressure, are controlled as necessary.

Page 4: Clean room technology

History

• Lord lister realized that elimination of bacteria can reduce infection.

• In 1860’s he used carbolic acid on instruments, wound and surgeons hands and prevent airborne by spraying into air.

• The use of nuclear fission, as well as the biological and chemical warfare research carried out during the 1939-1945 Second World War, were the driving forces for the production of High Efficiency Particulate Air (HEPA) filters necessary to contain the dangerous microbial or radioactive contaminants.

• In the early 1950s the Western Electric Company in Winston-Salem, NC, USA was having a major problem in manufacturing missile gyroscopes. About 99 out of 100 gyroscopes were being rejected, the problem being identified as dust.

Page 5: Clean room technology
Page 6: Clean room technology

• Cleanroom technology can be divided into three parts: design, testing and operation.• Cleanrooms have to be first designed and constructed; they then have

to be tested to ensure they achieve their design specification and continue to do so.• Finally they have to be operated in such a way as to minimise

contamination.

Page 7: Clean room technology

Importance

• A major user of cleanrooms is the semiconductor fabrication industry,

where processors are produced for use in computers, cars and other

machines.

• Figure shows a photomicrograph of a semiconductor with a particle on it. Such particles can cause an electrical short and ruin the semiconductor.

• To minimise contamination problems, semiconductors

Are manufactured in cleanrooms with very high

standards of cleanliness.

Page 8: Clean room technology

• Molecular contaminants (Out gassing, Oil vapour, Alcohols, Paints, glues, & epoxies, Aromatics; If you can smell it, suspect it as a contaminant.

• Surface contaminants Finger prints - Oil & grease Skin oil Hand cream Wax

• Particulate contaminants

People (skin, scales, hair, clothing lint, etc.)

Particle shedding materials (cardboard boxes, paper)

Abrading actions (drilling, sawing, sanding, etc.)

Page 9: Clean room technology

• Airborne concentration (count/m3) = Number of particles (or bacteria) generated / min/Air volume

supplied * ( m3 / min)

Page 10: Clean room technology

People ~75%Ventilation ~15%Room Structure ~5% Equipment ~5%

Page 11: Clean room technology
Page 12: Clean room technology

Types of Cleanrooms

• Cleanrooms have evolved into two major types and they are differentiated by their method of ventilation. These are turbulently ventilated and unidirectional flow cleanrooms. • Turbulently ventilated cleanrooms are also known as ‘non uni-

directional’. Unidirectional flow cleanrooms were originally known as ‘laminar flow’ cleanrooms. • This air sweeps across the room in a unidirectional way at and exits

through the floor, thus removing the airborne contamination from the room. This type of clean room uses very much more air than the turbulently ventilated type, and gives superior cleanliness.

Page 13: Clean room technology
Page 14: Clean room technology

• The type, number and placement of air supply diffusers, as well as the extract grilles, is an important consideration in a turbulently ventilated cleanroom. • Air diffusers are used in many air conditioned rooms and situated

where the supply air enters a room; they are designed to minimize the draught caused by high air velocities and ensure good air mixing.• It is possible to supply the air to a cleanroom with, or without, a

diffuser.

Page 15: Clean room technology

Diffuser

Page 16: Clean room technology

• In some conventionally ventilated cleanrooms, diffusers are not used and the supply air is ‘dumped’ down directly from the air filter into the cleanroom.• This method is chosen to obtain unidirectional flow and good

contamination control conditions under the filter

Page 17: Clean room technology

No diffuser (DUMP)

Page 18: Clean room technology

• ‘Dump’ methods will give enhanced conditions below the supply area, but must therefore give poorer conditions elsewhere in the room. • If enhanced conditions are required at critical areas, then it is better

to ensure good air mixing in the cleanroom by means of diffusers, and use unidirectional cabinets or workstations at the critical areas. • Diffusers should, however, be selected so that there are a sufficient

number and size to give good mixing and draught free conditions.

Page 19: Clean room technology

• If the ‘dump’ method is chosen then the filters should preferably be distributed evenly about the room. There may be an advantage in grouping the filters together to protect an area that must be kept clean. • However, if grouping is employed, it should be remembered that the

standard of the cleanroom is determined by the dirtiest part and this may give a lower classification.

Page 20: Clean room technology

ISO classification

• Cn is the maximum permitted concentration (in particles/m3 of air) of airborne particles that are equal to, or larger, than the considered particle size.

• Cn is rounded to the nearest whole number.

• N is the IS0 classification number, which shall not exceed the value of 9.

• Intermediate IS0 classification numbers may be specified, with 0.1 the smallest permitted increment of N.

• D is the considered particle size in µm.

• 0.1 is a constant with a dimension of µm.

Page 21: Clean room technology

Room pressurisation and air movement control between rooms• A cleanroom must be designed to ensure that contaminated air does not come into the room

from dirtier adjacent areas.

• Air should therefore always move from the cleanroom to less-clean adjacent areas. This means that the highest pressure should be in the production area

• If a cleanroom is at a higher pressure than an adjacent area then air will flow from the cleanroom to the adjacent area. Differential pressures of 10 Pa between two cleanrooms, and 15 Pa between a cleanroom and an unclassified area, are reasonable design pressures

Page 22: Clean room technology
Page 23: Clean room technology

High efficiency FILTERS

• HEPA and ULPA• High-Efficiency Particulate Air Filter• Ultra Low Penetration Air Filter• HEPA Collection Efficiency ≥ 99.97% (for 0.3 μm particles)• ULPA Collection Efficiency ≥ 99.999%(for 0.1-0.2 μm particles)• Paper-like mat of glass fibers perpendicular to airflow.• Fibers randomly oriented in the mat.• Organic binder is added for strength.

Page 24: Clean room technology
Page 25: Clean room technology

Diffusion

• Diffusion works on the smallest particles. Small particles are not held in place by the viscous fluid and diffuse(also known as Brownian movement) within the flow stream. As the particles traverse the flow stream, they collide with the fiber and are collected. • It is interesting to note that high efficiency filters are more efficient against particles than are smaller than the most penetrating size; this effect is Caused by diffusion.

Page 26: Clean room technology

Inertial Impaction

Inertia works on large, heavy particles suspended in the flow stream. These particles are heavier than the fluid surrounding them. As the fluid changes direction to enter the fiber space, the particle continues in a straight line and collides with the media fibers where it is trapped and held.

Page 27: Clean room technology

Interception Direct interception works on particles in the mid-range size that are not

quite large enough to have inertia and not small enough to diffuse within the flow stream. These mid-sized particles follow the flow stream as it bends through the fiber spaces. Particles are intercepted or captured when they touch a fiber.

Page 28: Clean room technology

• SievingSieving, the most common mechanism in filtration, occurs when

the particle is too large to fit between the fiber spaces.

Elecrostatic : when charged particles

Page 29: Clean room technology
Page 30: Clean room technology
Page 31: Clean room technology

Don’t:– touch your face or skin with gloves– touch building hardware, oily machinery, or wafer loading areas– lean on equipment– wear cosmetics, powders, or colognes– wear anything on fingers-- remove all rings and bracelets– use paper, pencils or markers that leave dust or lintDo:– change gloves whenever they get dirty or torn– use a fresh pair of gloves whenever handling wafers– wipe down wafer handling areas with isopropanol– use clean room paper and dust-free ball point pens

Page 32: Clean room technology

REFERENCE:

• Cleanroom Technology: Fundamentals of Design, Testing and Operation, W.Whyte, Copyright 2001 John Wiley & Sons Ltd Print ISBN 0-471-86842-6 Online ISBN 0--470-84777-8