Series CD12

AVENTICS™ Series CD12

Page 2: Catalog AVENTICS Series CD12 - Emerson

Page 2 | AVENTICS

3/2-directional valve, Series CD12- 3/2- Qn = 4000 l/min- Pilot valve width : 30 mm- NC/NO- Pipe connection- Compressed air connection output : G 1/2- Electrical connection : Plug, EN 175301-803, form A, 3-pin- -25 °C cold-resistant- Manual override : with detent, without detent- single solenoid- With spring return- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4000 l/minNominal flow 1 ▶ 2 4000 l/minNominal flow 2 ▶ 3 4000 l/minCompressed air connection according to ISO 228-1Pilot control exhaust with directional pilot air exhaustConnector standard EN 175301-803:2006Reverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 3: Catalog AVENTICS Series CD12 - Emerson

Page 3 | AVENTICS

Technical data

Part No. MO Compressed air connectionInput

5724550220 NC/NO G 1/25724555270 NC/NO G 1/25724555280 NC/NO G 1/25724555202 NC/NO G 1/25724560220 NC/NO G 1/25724565270 NC/NO G 1/25724565280 NC/NO G 1/25724565202 NC/NO G 1/2

Part No. Compressed air connection Compressed air connectionOutput Exhaust

5724550220 G 1/2 G 1/25724555270 G 1/2 G 1/25724555280 G 1/2 G 1/25724555202 G 1/2 G 1/25724560220 G 1/2 G 1/25724565270 G 1/2 G 1/25724565280 G 1/2 G 1/25724565202 G 1/2 G 1/2

Part No. Compressed air connection Compressed air connectionPilot Input Pilot Exhaust

5724550220 - M55724555270 - M55724555280 - M55724555202 - -5724560220 G 1/8 M55724565270 G 1/8 M55724565280 G 1/8 M55724565202 G 1/8 -

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz5724550220 24 V - -5724555270 - 110 V 110 V5724555280 - 230 V 230 V5724555202 - - -5724560220 24 V - -5724565270 - 110 V 110 V5724565280 - 230 V 230 V5724565202 - - -

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

5724550220 -10% / +10% - - 2.1 W5724555270 - -20% / +10% -10% / +20% -

PDF creation date: 20.06.2020

Page 4: Catalog AVENTICS Series CD12 - Emerson

Page 4 | AVENTICS

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

5724555280 - -20% / +10% -10% / +20% -5724555202 - - - -5724560220 -10% / +10% - - 2.1 W5724565270 - -20% / +10% -10% / +20% -5724565280 - -20% / +10% -10% / +20% -5724565202 - - - -

Part No. Holding power Holding power Switch-on power Switch-on power PilotAC 50 Hz AC 60 Hz AC 50 Hz AC 60 Hz

5724550220 - - - - Internal5724555270 4.3 VA 3.3 VA 6.8 VA 5.7 VA Internal5724555280 4.4 VA 3.5 VA 6.9 VA 6.2 VA Internal5724555202 - - - - Internal5724560220 - - - - External5724565270 4.3 VA 3.3 VA 6.8 VA 5.7 VA External5724565280 4.4 VA 3.5 VA 6.9 VA 6.2 VA External5724565202 - - - - External

Part No. Working pressure min./max. Control pressure min./max. Ambient temperature min./max.

5724550220 2 ... 10 bar 2 ... 10 bar -25 ... 50 °C5724555270 2 ... 10 bar 2 ... 10 bar -25 ... 50 °C5724555280 2 ... 10 bar 2 ... 10 bar -25 ... 50 °C5724555202 2 ... 16 bar 2 ... 16 bar -25 ... 70 °C5724560220 -0.95 ... 16 bar 2 ... 10 bar -25 ... 50 °C5724565270 -0.95 ... 16 bar 2 ... 10 bar -25 ... 50 °C5724565280 -0.95 ... 16 bar 2 ... 10 bar -25 ... 50 °C5724565202 -0.95 ... 16 bar 2 ... 16 bar -25 ... 70 °C

Part No. Medium temperature min./max. Typ. switch-on time Typ. switch-off time Compatibility index

5724550220 -25 ... 50 °C 34 ms 90 ms 13 145724555270 -25 ... 50 °C 34 ms 90 ms 13 145724555280 -25 ... 50 °C 34 ms 90 ms 13 145724555202 -25 ... 70 °C - - -5724560220 -25 ... 50 °C 34 ms 90 ms 13 145724565270 -25 ... 50 °C 34 ms 90 ms 13 145724565280 -25 ... 50 °C 34 ms 90 ms 13 145724565202 -25 ... 70 °C - - -

Part No. Protection class basic valve with electrical connectorwith connection

5724550220 IP65 -5724555270 IP65 -5724555280 IP65 -5724555202 - Basic valve without pilot valve5724560220 IP65 -5724565270 IP65 -5724565280 IP65 -

PDF creation date: 20.06.2020

Page 5: Catalog AVENTICS Series CD12 - Emerson

Page 5 | AVENTICS

Part No. Protection class basic valve with electrical connectorwith connection

5724565202 - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

5724550220 Protected against polarity reversal - 0.85 kg -5724555270 Protected against polarity reversal - 0.85 kg -5724555280 Protected against polarity reversal - 0.85 kg -5724555202 - ATEX optional 0.7 kg 1)5724560220 Protected against polarity reversal - 0.85 kg -5724565270 Protected against polarity reversal - 0.85 kg -5724565280 Protected against polarity reversal - 0.85 kg -5724565202 - ATEX optional 0.7 kg 1)

Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manual override1) temperature range for ATEX application: -10 °C ... 60 °C

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.option valve: The input and output compressed air connections can be exchanged.The valve can thereby be used in the NC or NO operating mode.*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 6: Catalog AVENTICS Series CD12 - Emerson

Page 6 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X (only for externally piloted valves) 5)Exhaust port of piston 6) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 7: Catalog AVENTICS Series CD12 - Emerson

Page 7 | AVENTICS

3/2-directional valve, Series CD12- 3/2- Qn = 4000 l/min- Pilot valve width : 30 mm- NC/NO- Pipe connection- Compressed air connection output : M22x1,5- Electrical connection : Plug, EN 175301-803, form A, 3-pin- -25 °C cold-resistant- Manual override : without detent- single solenoid- With spring return- Pilot : Internal

Version Spool valve, positive overlappingActivation ElectricallyPilot InternalSealing principle Soft sealingWorking pressure min./max. 2 ... 16 barControl pressure min./max. 2 ... 16 barAmbient temperature min./max. -25 ... 50 °CMedium temperature min./max. -25 ... 50 °CMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4000 l/minNominal flow 1 ▶ 2 4000 l/minNominal flow 2 ▶ 3 4000 l/minPilot control exhaust with directional pilot air exhaustConnector standard EN 175301-803:2006Protection class with connection IP65Reverse polarity protection Protected against polarity reversalCompatibility index 14Duty cycle 100 %Typ. switch-on time 34 msTyp. switch-off time 90 msWeight 0.85 kg

PDF creation date: 20.06.2020

Page 8: Catalog AVENTICS Series CD12 - Emerson

Page 8 | AVENTICS

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

5724500920 NC/NO M22x1,5 M22x1,55724505970 NC/NO M22x1,5 M22x1,55724505980 NC/NO M22x1,5 M22x1,5

Part No. Compressed air connection Compressed air connectionExhaust Pilot Exhaust

5724500920 M22x1,5 M55724505970 M22x1,5 M55724505980 M22x1,5 M5

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz5724500920 24 V - -5724505970 - 110 V 110 V5724505980 - 230 V 230 V

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

5724500920 -10% / +10% - - 6.7 W5724505970 - -20% / +10% -10% / +20% -5724505980 - -20% / +10% -10% / +20% -

Part No. Holding power Holding power Switch-on power Switch-on powerAC 50 Hz AC 60 Hz AC 50 Hz AC 60 Hz

5724500920 - - - -5724505970 10.5 VA 7.6 VA 14.5 VA 12 VA5724505980 10.8 VA 7.8 VA 15.2 VA 12.7 VA

Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manual override

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.option valve: The input and output compressed air connections can be exchanged.The valve can thereby be used in the NC or NO operating mode.*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

PDF creation date: 20.06.2020

Page 9: Catalog AVENTICS Series CD12 - Emerson

Page 9 | AVENTICS

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X (only for externally piloted valves) 5)Exhaust port of piston 6) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 10: Catalog AVENTICS Series CD12 - Emerson

Page 10 | AVENTICS

5/2-directional valve, Series CD12- 5/2- Qn = 4100 l/min- Pilot valve width : 30 mm- Pipe connection- Compressed air connection output : G 1/2- Electrical connection : Plug, EN 175301-803, form A, 3-pin- Manual override : with detent, without detent- single solenoid- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4100 l/minCompressed air connection according to ISO 228-1Pilot control exhaust with directional pilot air exhaustReverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 11: Catalog AVENTICS Series CD12 - Emerson

Page 11 | AVENTICS

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

5725450220 G 1/2 G 1/25725455270 G 1/2 G 1/25725455280 G 1/2 G 1/25725455202 G 1/2 G 1/25725455302 G 1/2 G 1/25725470220 G 1/2 G 1/25725475270 G 1/2 G 1/25725475280 G 1/2 G 1/25725475202 G 1/2 G 1/2R412008096 G 1/2 G 1/25725480220 G 1/2 G 1/25725485270 G 1/2 G 1/25725485280 G 1/2 G 1/25725485202 G 1/2 G 1/2

Part No. Compressed air connection Compressed air connectionExhaust Pilot Input

5725450220 G 1/2 -5725455270 G 1/2 -5725455280 G 1/2 -5725455202 G 1/2 -5725455302 G 1/2 -5725470220 G 1/2 -5725475270 G 1/2 -5725475280 G 1/2 -5725475202 G 1/2 -R412008096 G 1/2 -5725480220 G 1/2 G 1/85725485270 G 1/2 G 1/85725485280 G 1/2 G 1/85725485202 G 1/2 G 1/8

Part No. Compressed air connection Operationalvoltage

Operationalvoltage

Pilot Exhaust DC AC 50 Hz5725450220 M5 24 V -5725455270 M5 - 110 V5725455280 M5 - 230 V5725455202 - - -5725455302 M5 - -5725470220 M5 24 V -5725475270 M5 - 110 V5725475280 M5 - 230 V5725475202 - - -R412008096 - - -5725480220 M5 24 V -

PDF creation date: 20.06.2020

Page 12: Catalog AVENTICS Series CD12 - Emerson

Page 12 | AVENTICS

Part No. Compressed air connection Operationalvoltage

Operationalvoltage

Pilot Exhaust DC AC 50 Hz5725485270 M5 - 110 V5725485280 M5 - 230 V5725485202 - - -

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 Hz5725450220 - -10% / +10% - -5725455270 110 V - -20% / +10% -10% / +20%5725455280 230 V - -20% / +10% -10% / +20%5725455202 - - - -5725455302 - - - -5725470220 - -10% / +10% - -5725475270 110 V - -20% / +10% -10% / +20%5725475280 230 V - -20% / +10% -10% / +20%5725475202 - - - -R412008096 - - - -5725480220 - -10% / +10% - -5725485270 110 V - -20% / +10% -10% / +20%5725485280 230 V - -20% / +10% -10% / +20%5725485202 - - - -

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

5725450220 2.1 W - - -5725455270 - 4.3 VA 3.3 VA 6.8 VA5725455280 - 4.4 VA 3.5 VA 6.9 VA5725455202 - - - -5725455302 - - - -5725470220 2.1 W - - -5725475270 - 4.3 VA 3.3 VA 6.8 VA5725475280 - 4.4 VA 3.5 VA 6.9 VA5725475202 - - - -R412008096 - - - -5725480220 2.1 W - - -5725485270 - 4.3 VA 3.3 VA 6.8 VA5725485280 - 4.4 VA 3.5 VA 6.9 VA5725485202 - - - -

Part No. Switch-on power Pilot Working pressure min./max. Control pressure min./max.AC 60 Hz

5725450220 - Internal 2 ... 10 bar 2 ... 10 bar5725455270 5.7 VA Internal 2 ... 10 bar 2 ... 10 bar5725455280 6.2 VA Internal 2 ... 10 bar 2 ... 10 bar5725455202 - Internal 2 ... 16 bar 2 ... 16 bar5725455302 - Internal 2 ... 10 bar 2 ... 10 bar5725470220 - Internal 2 ... 10 bar 2 ... 10 bar5725475270 5.7 VA Internal 2 ... 10 bar 2 ... 10 bar5725475280 6.2 VA Internal 2 ... 10 bar 2 ... 10 bar

PDF creation date: 20.06.2020

Page 13: Catalog AVENTICS Series CD12 - Emerson

Page 13 | AVENTICS

Part No. Switch-on power Pilot Working pressure min./max. Control pressure min./max.AC 60 Hz

5725475202 - Internal 2 ... 16 bar 2 ... 16 barR412008096 - Internal 2 ... 10 bar 2 ... 10 bar5725480220 - External -0.95 ... 16 bar 2 ... 10 bar5725485270 5.7 VA External -0.95 ... 16 bar 2 ... 10 bar5725485280 6.2 VA External -0.95 ... 16 bar 2 ... 10 bar5725485202 - External -0.95 ... 16 bar 2 ... 10 bar

Part No. Ambient temperature min./max. Medium temperature min./max. Typ. switch-on time

5725450220 -25 ... 50 °C -25 ... 50 °C 37 ms5725455270 -25 ... 50 °C -25 ... 50 °C 37 ms5725455280 -25 ... 50 °C -25 ... 50 °C 37 ms5725455202 -25 ... 70 °C -25 ... 70 °C -5725455302 -25 ... 50 °C -25 ... 50 °C -5725470220 -15 ... 50 °C -15 ... 50 °C 37 ms5725475270 -15 ... 50 °C -15 ... 50 °C 37 ms5725475280 -15 ... 50 °C -15 ... 50 °C 37 ms5725475202 -15 ... 70 °C -15 ... 70 °C -R412008096 -15 ... 50 °C -15 ... 50 °C -5725480220 -15 ... 50 °C -15 ... 50 °C 37 ms5725485270 -15 ... 50 °C -15 ... 50 °C 37 ms5725485280 -15 ... 50 °C -15 ... 50 °C 37 ms5725485202 -15 ... 70 °C -15 ... 70 °C -

Part No. Typ. switch-off time Compatibility index Protection class basic valve with electrical connectorwith connection

5725450220 97 ms 13 14 IP65 -5725455270 97 ms 13 14 IP65 -5725455280 97 ms 13 14 IP65 -5725455202 - - - Basic valve without pilot valve5725455302 - - - Basic valve without coil5725470220 97 ms 13 14 IP65 -5725475270 97 ms 13 14 IP65 -5725475280 97 ms 13 14 IP65 -5725475202 - - - Basic valve without pilot valveR412008096 - 13 14 - Basic valve without coil5725480220 97 ms 13 14 IP65 -5725485270 97 ms 13 14 IP65 -5725485280 97 ms 13 14 IP65 -5725485202 97 ms - - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

5725450220 Protected against polarity reversal - 1 kg -5725455270 Protected against polarity reversal - 1 kg -5725455280 Protected against polarity reversal - 1 kg -5725455202 - ATEX optional 0.85 kg 1)5725455302 - ATEX optional 0.85 kg -5725470220 Protected against polarity reversal - 1 kg -

PDF creation date: 20.06.2020

Page 14: Catalog AVENTICS Series CD12 - Emerson

Page 14 | AVENTICS

Part No. Reverse polarity protection ATEX Weight

5725475270 Protected against polarity reversal - 1 kg -5725475280 Protected against polarity reversal - 1 kg -5725475202 - ATEX optional 0.85 kg 1)R412008096 - ATEX optional 0.85 kg 2)5725480220 Protected against polarity reversal - 1 kg -5725485270 Protected against polarity reversal - 1 kg -5725485280 Protected against polarity reversal - 1 kg -5725485202 - ATEX optional 1 kg -

Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manual override1) temperature range for ATEX application: -10 °C ... 60 °C2) Exhaust cap

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 15: Catalog AVENTICS Series CD12 - Emerson

Page 15 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X (only for externally piloted valves) 5)Exhaust port of piston 6) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 16: Catalog AVENTICS Series CD12 - Emerson

Page 16 | AVENTICS

5/2-directional valve, Series CD12- 5/2- Qn = 4100 l/min- Pilot valve width : 30 mm- Pipe connection- Compressed air connection output : M22x1,5- Electrical connection : Plug, EN 175301-803, form A, 3-pin- -25 °C cold-resistant- Manual override : with detent, without detent- single solenoid- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4100 l/minPilot control exhaust with directional pilot air exhaustReverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 17: Catalog AVENTICS Series CD12 - Emerson

Page 17 | AVENTICS

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

5725400220 M22x1,5 M22x1,55725405270 M22x1,5 M22x1,55725405280 M22x1,5 M22x1,55725405202 M22x1,5 M22x1,5R412013341 M22x1,5 M22x1,5R412013342 M22x1,5 M22x1,5R412000243 M22x1,5 M22x1,5R412000242 M22x1,5 M22x1,5

Part No. Compressed air connection Compressed air connectionExhaust Pilot Input

5725400220 M22x1,5 -5725405270 M22x1,5 -5725405280 M22x1,5 -5725405202 M22x1,5 -R412013341 M22x1,5 -R412013342 M22x1,5 -R412000243 M22x1,5 -R412000242 M22x1,5 G 1/8

Part No. Compressed air connection Operationalvoltage

Operationalvoltage

Pilot Exhaust DC AC 50 Hz5725400220 M5 24 V -5725405270 M5 - 110 V5725405280 M5 - 230 V5725405202 - - -R412013341 M5 24 V -R412013342 M5 - 230 VR412000243 - - -R412000242 - - -

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 Hz5725400220 - -10% / +10% - -5725405270 110 V - -20% / +10% -10% / +20%5725405280 230 V - -20% / +10% -10% / +20%5725405202 - - - -R412013341 - -10% / +10% - -R412013342 230 V - -20% / +10% -10% / +20%R412000243 - - - -R412000242 - - - -

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

5725400220 2.1 W - - -

PDF creation date: 20.06.2020

Page 18: Catalog AVENTICS Series CD12 - Emerson

Page 18 | AVENTICS

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

5725405270 - 4.3 VA 3.3 VA 6.8 VA5725405280 - 4.4 VA 3.5 VA 6.9 VA5725405202 - - - -R412013341 2.1 W - - -R412013342 - 4.4 VA 3.5 VA 6.9 VAR412000243 - - - -R412000242 - - - -

Part No. Switch-on power Pilot Working pressure min./max. Control pressure min./max.AC 60 Hz

5725400220 - Internal 2 ... 10 bar 2 ... 10 bar5725405270 5.7 VA Internal 2 ... 10 bar 2 ... 10 bar5725405280 6.2 VA Internal 2 ... 10 bar 2 ... 10 bar5725405202 - Internal 2 ... 16 bar 2 ... 16 barR412013341 - Internal 2 ... 10 bar 2 ... 10 barR412013342 6.2 VA Internal 2 ... 10 bar 2 ... 10 barR412000243 - Internal 2 ... 16 bar 2 ... 16 barR412000242 - External -0.95 ... 16 bar 2 ... 10 bar

Part No. Ambient temperature min./max. Medium temperature min./max. Typ. switch-on time

5725400220 -25 ... 50 °C -25 ... 50 °C 37 ms5725405270 -25 ... 50 °C -25 ... 50 °C 37 ms5725405280 -25 ... 50 °C -25 ... 50 °C 37 ms5725405202 -25 ... 70 °C -25 ... 70 °C -R412013341 -15 ... 50 °C -15 ... 50 °C 37 msR412013342 -15 ... 50 °C -15 ... 50 °C 37 msR412000243 -15 ... 70 °C -15 ... 70 °C -R412000242 -15 ... 70 °C -15 ... 70 °C -

Part No. Typ. switch-off time Compatibility index Protection class basic valve with electrical connectorwith connection

5725400220 97 ms 13 14 IP65 -5725405270 97 ms 13 14 IP65 -5725405280 97 ms 13 14 IP65 -5725405202 - - - Basic valve without pilot valveR412013341 97 ms 13 14 IP65 -R412013342 97 ms 14 IP65 -R412000243 - - - Basic valve without pilot valveR412000242 97 ms - - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

5725400220 Protected against polarity reversal - 0.99 kg5725405270 Protected against polarity reversal - 0.99 kg5725405280 Protected against polarity reversal - 0.99 kg5725405202 - ATEX optional 0.84 kgR412013341 Protected against polarity reversal - 1 kgR412013342 Protected against polarity reversal - 1 kg

PDF creation date: 20.06.2020

Page 19: Catalog AVENTICS Series CD12 - Emerson

Page 19 | AVENTICS

Part No. Reverse polarity protection ATEX Weight

R412000243 - ATEX optional 0.84 kgR412000242 - ATEX optional 1 kg

Base valves without pilot valves can be combined with DO30 series valves., Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manualoverride

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 20: Catalog AVENTICS Series CD12 - Emerson

Page 20 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X (only for externally piloted valves) 5)Exhaust port of piston 6) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 21: Catalog AVENTICS Series CD12 - Emerson

Page 21 | AVENTICS

5/2-directional valve, Series CD12- 5/2- Qn = 4100 l/min- Pilot valve width : 30 mm- Pipe connection- Compressed air connection output : G 1/2- Electrical connection : Plug, EN 175301-803, form A, 3-pin- -25 °C cold-resistant- Manual override : with detent, without detent- double solenoid- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4100 l/minCompressed air connection according to ISO 228-1Pilot control exhaust with directional pilot air exhaustConnector standard EN 175301-803:2006Reverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 22: Catalog AVENTICS Series CD12 - Emerson

Page 22 | AVENTICS

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

R412008097 G 1/2 G 1/25725550220 G 1/2 G 1/25725555270 G 1/2 G 1/25725555280 G 1/2 G 1/25725555202 G 1/2 G 1/25725560220 G 1/2 G 1/25725565270 G 1/2 G 1/25725565280 G 1/2 G 1/25725565202 G 1/2 G 1/2

Part No. Compressed air connection Compressed air connectionExhaust Pilot Input

R412008097 G 1/2 -5725550220 G 1/2 -5725555270 G 1/2 -5725555280 G 1/2 -5725555202 G 1/2 -5725560220 G 1/2 G 1/85725565270 G 1/2 G 1/85725565280 G 1/2 G 1/85725565202 G 1/2 G 1/8

Part No. Compressed air connection Operationalvoltage

Operationalvoltage

Pilot Exhaust DC AC 50 HzR412008097 - - -5725550220 M5 24 V -5725555270 M5 - 110 V5725555280 M5 - 230 V5725555202 - - -5725560220 M5 24 V -5725565270 M5 - 110 V5725565280 M5 - 230 V5725565202 - - -

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 HzR412008097 - - - -5725550220 - -10% / +10% - -5725555270 110 V - -20% / +10% -10% / +20%5725555280 230 V - -20% / +10% -10% / +20%5725555202 - - - -5725560220 - -10% / +10% - -5725565270 110 V - -20% / +10% -10% / +20%5725565280 230 V - -20% / +10% -10% / +20%5725565202 - - - -

PDF creation date: 20.06.2020

Page 23: Catalog AVENTICS Series CD12 - Emerson

Page 23 | AVENTICS

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

R412008097 - - - -5725550220 2.1 W - - -5725555270 - 4.3 VA 3.3 VA 6.8 VA5725555280 - 4.4 VA 3.5 VA 6.9 VA5725555202 - - - -5725560220 2.1 W - - -5725565270 - 4.3 VA 3.3 VA 6.8 VA5725565280 - 4.4 VA 3.5 VA 6.9 VA5725565202 - - - -

Part No. Switch-on power Pilot Working pressure min./max. Control pressure min./max.AC 60 Hz

R412008097 - Internal 2 ... 10 bar 2 ... 10 bar5725550220 - Internal 2 ... 10 bar 2 ... 10 bar5725555270 5.7 VA Internal 2 ... 10 bar 2 ... 10 bar5725555280 6.2 VA Internal 2 ... 10 bar 2 ... 10 bar5725555202 - Internal 2 ... 16 bar 2 ... 16 bar5725560220 - External -0.95 ... 16 bar 2 ... 10 bar5725565270 5.7 VA External -0.95 ... 16 bar 2 ... 10 bar5725565280 6.2 VA External -0.95 ... 16 bar 2 ... 10 bar5725565202 - External -0.95 ... 16 bar 2 ... 16 bar

Part No. Ambient temperature min./max. Medium temperature min./max. Typ. switch-on time

R412008097 -25 ... 50 °C -25 ... 50 °C -5725550220 -25 ... 50 °C -25 ... 50 °C 36 ms5725555270 -25 ... 50 °C -25 ... 50 °C 36 ms5725555280 -25 ... 50 °C -25 ... 50 °C 36 ms5725555202 -25 ... 70 °C -25 ... 70 °C -5725560220 -25 ... 50 °C -25 ... 50 °C 36 ms5725565270 -25 ... 50 °C -25 ... 50 °C 36 ms5725565280 -25 ... 50 °C -25 ... 50 °C 36 ms5725565202 -25 ... 70 °C -25 ... 70 °C -

Part No. Typ. switch-off time Compatibility index Protection class basic valve with electrical connectorwith connection

R412008097 - 13 14 - Basic valve without coil5725550220 36 ms 13 14 IP65 -5725555270 36 ms 13 14 IP65 -5725555280 36 ms 13 14 IP65 -5725555202 - - - Basic valve without pilot valve5725560220 36 ms 13 14 IP65 -5725565270 36 ms 13 14 IP65 -5725565280 36 ms 13 14 IP65 -5725565202 - - - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

R412008097 - ATEX optional 0.9 kg 1)

PDF creation date: 20.06.2020

Page 24: Catalog AVENTICS Series CD12 - Emerson

Page 24 | AVENTICS

Part No. Reverse polarity protection ATEX Weight

5725550220 Protected against polarity reversal - 1.2 kg -5725555270 Protected against polarity reversal - 1.2 kg -5725555280 Protected against polarity reversal - 1.2 kg -5725555202 - ATEX optional 0.9 kg -5725560220 Protected against polarity reversal - 1.2 kg -5725565270 Protected against polarity reversal - 1.2 kg -5725565280 Protected against polarity reversal - 1.2 kg -5725565202 - ATEX optional 0.9 kg -

Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manual override1) Exhaust cap

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 25: Catalog AVENTICS Series CD12 - Emerson

Page 25 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X, side 14 5) Port X, side 12 6) Port withoutfunction 7) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 26: Catalog AVENTICS Series CD12 - Emerson

Page 26 | AVENTICS

5/2-directional valve, Series CD12- 5/2- Qn = 4100 l/min- Pilot valve width : 30 mm- Pipe connection- Compressed air connection output : M22x1,5- Electrical connection : Plug, EN 175301-803, form A, 3-pin- -25 °C cold-resistant- Manual override : with detent, without detent- double solenoid- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn 4100 l/minPilot control exhaust with directional pilot air exhaustConnector standard EN 175301-803:2006Reverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 27: Catalog AVENTICS Series CD12 - Emerson

Page 27 | AVENTICS

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

5725500220 M22x1,5 M22x1,55725505270 M22x1,5 M22x1,55725505280 M22x1,5 M22x1,55725505202 M22x1,5 M22x1,5R412000244 M22x1,5 M22x1,5

Part No. Compressed air connection Compressed air connectionExhaust Pilot Input

5725500220 M22x1,5 -5725505270 M22x1,5 -5725505280 M22x1,5 -5725505202 M22x1,5 -R412000244 M22x1,5 G 1/8

Part No. Compressed air connection Operationalvoltage

Operationalvoltage

Pilot Exhaust DC AC 50 Hz5725500220 M5 24 V -5725505270 M5 - 110 V5725505280 M5 - 230 V5725505202 - - -R412000244 - - -

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 Hz5725500220 - -10% / +10% - -5725505270 110 V - -20% / +10% -10% / +20%5725505280 230 V - -20% / +10% -10% / +20%5725505202 - - - -R412000244 - - - -

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

5725500220 2.1 W - - -5725505270 - 4.3 VA 3.3 VA 6.8 VA5725505280 - 4.4 VA 3.5 VA 6.9 VA5725505202 - - - -R412000244 - - - -

Part No. Switch-on power Pilot Working pressure min./max. Control pressure min./max.AC 60 Hz

5725500220 - Internal 2 ... 10 bar 2 ... 16 bar5725505270 5.7 VA Internal 2 ... 10 bar 2 ... 10 bar5725505280 6.2 VA Internal 2 ... 10 bar 2 ... 10 bar5725505202 - Internal 2 ... 16 bar 2 ... 16 barR412000244 - External -0.95 ... 16 bar 2 ... 16 bar

PDF creation date: 20.06.2020

Page 28: Catalog AVENTICS Series CD12 - Emerson

Page 28 | AVENTICS

Part No. Ambient temperature min./max. Medium temperature min./max. Typ. switch-on time

5725500220 -25 ... 50 °C -25 ... 50 °C 36 ms5725505270 -25 ... 50 °C -25 ... 50 °C 36 ms5725505280 -15 ... 50 °C -15 ... 50 °C 36 ms5725505202 -25 ... 70 °C -25 ... 70 °C -R412000244 -25 ... 70 °C -25 ... 70 °C -

Part No. Typ. switch-off time Compatibility index Protection class basic valve with electrical connectorwith connection

5725500220 36 ms 13 14 IP65 -5725505270 36 ms 13 14 IP65 -5725505280 36 ms 13 14 IP65 -5725505202 - - - Basic valve without pilot valveR412000244 - - - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

5725500220 Protected against polarity reversal - 1.1 kg5725505270 Protected against polarity reversal - 1.1 kg5725505280 Protected against polarity reversal - 1.1 kg5725505202 - ATEX optional 0.8 kgR412000244 - ATEX optional 0.9 kg

Base valves without pilot valves can be combined with DO30 series valves., Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manualoverride

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 29: Catalog AVENTICS Series CD12 - Emerson

Page 29 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X, side 14 5) Port X, side 12 6) Port withoutfunction 7) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 30: Catalog AVENTICS Series CD12 - Emerson

Page 30 | AVENTICS

5/3-directional valve, Series CD12- 5/3- Qn = 3800 l/min- Pilot valve width : 30 mm- closed center exhausted center pressurized center- Pipe connection- Compressed air connection output : G 1/2- Electrical connection : Plug, EN 175301-803, form A, 3-pin- Manual override : with detent, without detent- double solenoid- With spring return- Pilot : Internal External

Version Spool valve, positive overlappingActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowControl pressure min./max. See table belowAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Nominal flow Qn See table belowNominal flow 1 ▶ 2 See table belowNominal flow 2 ▶ 3 See table belowCompressed air connection according to ISO 228-1Pilot control exhaust with directional pilot air exhaustConnector standard EN 175301-803:2006Reverse polarity protection Protected against polarity reversalCompatibility index See table belowDuty cycle 100 %Weight See table below

PDF creation date: 20.06.2020

Page 31: Catalog AVENTICS Series CD12 - Emerson

Page 31 | AVENTICS

Technical data

Part No. MO Compressed air connectionInput

5725650220 closed center G 1/25725650920 closed center G 1/25725655270 closed center G 1/25725655280 closed center G 1/25725655980 closed center G 1/25725655202 closed center G 1/2R412008098 closed center G 1/2R412000127 closed center G 1/2R412000148 closed center G 1/2R412000149 closed center G 1/2R412000151 closed center G 1/2R412000224 exhausted center G 1/2R412000225 exhausted center G 1/2R412000230 exhausted center G 1/2R412000237 exhausted center G 1/25725680220 exhausted center G 1/25725685270 exhausted center G 1/25725685280 exhausted center G 1/25725685202 exhausted center G 1/2R412000219 pressurized center G 1/2R412000220 pressurized center G 1/2R412000221 pressurized center G 1/2R412000222 pressurized center G 1/2R412000153 pressurized center G 1/2R412000154 pressurized center G 1/2R412000157 pressurized center G 1/2R412000160 pressurized center G 1/2

Part No. Compressed air connection Compressed air connectionOutput Exhaust

5725650220 G 1/2 G 1/25725650920 G 1/2 G 1/25725655270 G 1/2 G 1/25725655280 G 1/2 G 1/25725655980 G 1/2 G 1/25725655202 G 1/2 G 1/2R412008098 G 1/2 G 1/2R412000127 G 1/2 G 1/2R412000148 G 1/2 G 1/2R412000149 G 1/2 G 1/2R412000151 G 1/2 G 1/2R412000224 G 1/2 G 1/2R412000225 G 1/2 G 1/2R412000230 G 1/2 G 1/2R412000237 G 1/2 G 1/25725680220 G 1/2 G 1/2

PDF creation date: 20.06.2020

Page 32: Catalog AVENTICS Series CD12 - Emerson

Page 32 | AVENTICS

Part No. Compressed air connection Compressed air connectionOutput Exhaust

5725685270 G 1/2 G 1/25725685280 G 1/2 G 1/25725685202 G 1/2 G 1/2R412000219 G 1/2 G 1/2R412000220 G 1/2 G 1/2R412000221 G 1/2 G 1/2R412000222 G 1/2 G 1/2R412000153 G 1/2 G 1/2R412000154 G 1/2 G 1/2R412000157 G 1/2 G 1/2R412000160 G 1/2 G 1/2

Part No. Compressed air connection Compressed air connectionPilot Input Pilot Exhaust

5725650220 - M55725650920 - -5725655270 - M55725655280 - M55725655980 - -5725655202 - -R412008098 - M5R412000127 G 1/8 M5R412000148 G 1/8 M5R412000149 G 1/8 M5R412000151 G 1/8 -R412000224 - M5R412000225 - M5R412000230 - M5R412000237 - -5725680220 G 1/8 M55725685270 G 1/8 M55725685280 G 1/8 M55725685202 G 1/8 -R412000219 - M5R412000220 - M5R412000221 - M5R412000222 - -R412000153 G 1/8 M5R412000154 G 1/8 M5R412000157 G 1/8 M5R412000160 G 1/8 -

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz5725650220 24 V - -5725650920 24 V - -5725655270 - 110 V 110 V5725655280 - 230 V 230 V

PDF creation date: 20.06.2020

Page 33: Catalog AVENTICS Series CD12 - Emerson

Page 33 | AVENTICS

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz5725655980 - 230 V 230 V5725655202 - - -R412008098 - - -R412000127 24 V - -R412000148 - 110 V 110 VR412000149 - 230 V 230 VR412000151 - - -R412000224 24 V - -R412000225 - 110 V 110 VR412000230 - 230 V 230 VR412000237 - - -5725680220 24 V - -5725685270 - 110 V 110 V5725685280 - 230 V 230 V5725685202 - - -R412000219 24 V - -R412000220 - 110 V 110 VR412000221 - 230 V 230 VR412000222 - - -R412000153 24 V - -R412000154 - 110 V 110 VR412000157 - 230 V 230 VR412000160 - - -

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

5725650220 -10% / +10% - - 2.1 W5725650920 -10% / +10% - - 2.1 W5725655270 - -20% / +10% -10% / +20% -5725655280 - -20% / +10% -10% / +20% -5725655980 - -20% / +10% -10% / +20% -5725655202 - - - -R412008098 - - - -R412000127 -10% / +10% - - 2.1 WR412000148 - -20% / +10% -10% / +20% -R412000149 - -20% / +10% -10% / +20% -R412000151 - - - -R412000224 -10% / +10% - - 2.1 WR412000225 - -20% / +10% -10% / +20% -R412000230 - -20% / +10% -10% / +20% -R412000237 - - - -5725680220 -10% / +10% - - 2.1 W5725685270 - -20% / +10% -10% / +20% -5725685280 - -20% / +10% -10% / +20% -5725685202 - - - -R412000219 -10% / +10% - - 2.1 WR412000220 - -20% / +10% -10% / +20% -R412000221 - -20% / +10% -10% / +20% -

PDF creation date: 20.06.2020

Page 34: Catalog AVENTICS Series CD12 - Emerson

Page 34 | AVENTICS

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

R412000222 - - - -R412000153 -10% / +10% - - 2.1 WR412000154 - -20% / +10% -10% / +20% -R412000157 - -20% / +10% -10% / +20% -R412000160 - - - -

Part No. Holding power Holding power Switch-on power Switch-on power PilotAC 50 Hz AC 60 Hz AC 50 Hz AC 60 Hz

5725650220 - - - - Internal5725650920 - - - - Internal5725655270 4.3 VA 3.3 VA 6.8 VA 5.7 VA Internal5725655280 4.4 VA 3.5 VA 6.9 VA 6.2 VA Internal5725655980 4.4 VA 3.5 VA 6.9 VA 6.2 VA Internal5725655202 - - - - InternalR412008098 - - - - InternalR412000127 - - - - ExternalR412000148 4.3 VA 3.3 VA 6.8 VA 5.7 VA ExternalR412000149 4.4 VA 3.5 VA 6.9 VA 6.2 VA ExternalR412000151 - - - - ExternalR412000224 - - - - InternalR412000225 4.3 VA 3.3 VA 6.8 VA 5.7 VA InternalR412000230 4.4 VA 3.5 VA 6.9 VA 6.2 VA InternalR412000237 - - - - Internal5725680220 - - - - External5725685270 4.3 VA 3.3 VA 6.8 VA 5.7 VA External5725685280 4.4 VA 3.5 VA 6.9 VA 6.2 VA External5725685202 - - - - ExternalR412000219 - - - - InternalR412000220 4.3 VA 3.3 VA 6.8 VA 5.7 VA InternalR412000221 4.4 VA 3.5 VA 6.9 VA 6.2 VA InternalR412000222 - - - - InternalR412000153 - - - - ExternalR412000154 4.3 VA 3.3 VA 6.8 VA 5.7 VA ExternalR412000157 4.4 VA 3.5 VA 6.9 VA 6.2 VA ExternalR412000160 - - - - External

Part No. Nominal flow Qn Nominal flow 1 ▶ 2 Nominal flow 2 ▶ 3 Working pressure min./max. Control pressure min./max.

5725650220 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 bar5725650920 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 bar5725655270 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 bar5725655280 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 bar5725655980 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 bar5725655202 3800 l/min 3800 l/min 3800 l/min 3 ... 16 bar 3 ... 16 barR412008098 3800 l/min 3800 l/min 3800 l/min 3 ... 10 bar 3 ... 10 barR412000127 3800 l/min 3800 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000148 3800 l/min 3800 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000149 3800 l/min 3800 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000151 3800 l/min 3800 l/min 3800 l/min -0.95 ... 16 bar 3 ... 16 bar

PDF creation date: 20.06.2020

Page 35: Catalog AVENTICS Series CD12 - Emerson

Page 35 | AVENTICS

Part No. Nominal flow Qn Nominal flow 1 ▶ 2 Nominal flow 2 ▶ 3 Working pressure min./max. Control pressure min./max.

R412000224 - 3600 l/min 4100 l/min 3 ... 10 bar 3 ... 10 barR412000225 - 3600 l/min 4100 l/min 3 ... 10 bar 3 ... 10 barR412000230 - 3600 l/min 4100 l/min 3 ... 10 bar 3 ... 10 barR412000237 - 3600 l/min 4100 l/min 3 ... 16 bar 3 ... 16 bar5725680220 - 3600 l/min 4100 l/min -0.95 ... 16 bar 3 ... 10 bar5725685270 - 3600 l/min 4100 l/min -0.95 ... 16 bar 3 ... 10 bar5725685280 - 3600 l/min 4100 l/min -0.95 ... 16 bar 3 ... 10 bar5725685202 - 3600 l/min 4100 l/min -0.95 ... 16 bar 3 ... 16 barR412000219 - 4100 l/min 3800 l/min 3 ... 10 bar 3 ... 10 barR412000220 - 4100 l/min 3800 l/min 3 ... 10 bar 3 ... 10 barR412000221 - 4100 l/min 3800 l/min 3 ... 10 bar 3 ... 10 barR412000222 - 4100 l/min 3800 l/min 3 ... 16 bar 3 ... 16 barR412000153 - 4100 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000154 - 4100 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000157 - 4100 l/min 3800 l/min -0.95 ... 16 bar 3 ... 10 barR412000160 - 4100 l/min 3800 l/min -0.95 ... 16 bar 3 ... 16 bar

Part No. Ambient temperature min./max. Medium temperature min./max. Typ. switch-on time

5725650220 -15 ... 50 °C -15 ... 50 °C 37 ms5725650920 -15 ... 50 °C -15 ... 50 °C 37 ms5725655270 -15 ... 50 °C -15 ... 50 °C 37 ms5725655280 -15 ... 50 °C -15 ... 50 °C 37 ms5725655980 -15 ... 50 °C -15 ... 50 °C 37 ms5725655202 -15 ... 70 °C -15 ... 70 °C -R412008098 -15 ... 50 °C -15 ... 50 °C -R412000127 -15 ... 50 °C -15 ... 50 °C 37 msR412000148 -15 ... 50 °C -15 ... 50 °C 37 msR412000149 -15 ... 50 °C -15 ... 50 °C 37 msR412000151 -15 ... 70 °C -15 ... 70 °C -R412000224 -15 ... 50 °C -15 ... 50 °C 37 msR412000225 -15 ... 50 °C -15 ... 50 °C 37 msR412000230 -15 ... 50 °C -15 ... 50 °C 37 msR412000237 -15 ... 70 °C -15 ... 70 °C -5725680220 -15 ... 50 °C -15 ... 50 °C 37 ms5725685270 -15 ... 50 °C -15 ... 50 °C 37 ms5725685280 -15 ... 50 °C -15 ... 50 °C 37 ms5725685202 -15 ... 70 °C -15 ... 70 °C -R412000219 -15 ... 50 °C -15 ... 50 °C 37 msR412000220 -15 ... 50 °C -15 ... 50 °C 37 msR412000221 -15 ... 50 °C -15 ... 50 °C 37 msR412000222 -15 ... 70 °C -15 ... 70 °C -R412000153 -15 ... 50 °C -15 ... 50 °C 37 msR412000154 -15 ... 50 °C -15 ... 50 °C 37 msR412000157 -15 ... 50 °C -15 ... 50 °C 37 msR412000160 -15 ... 70 °C -15 ... 70 °C -

PDF creation date: 20.06.2020

Page 36: Catalog AVENTICS Series CD12 - Emerson

Page 36 | AVENTICS

Part No. Typ. switch-off time Compatibility index Protection class basic valve with electrical connectorwith connection

5725650220 97 ms 13 14 IP65 -5725650920 97 ms 13 14 IP65 -5725655270 97 ms 13 14 IP65 -5725655280 97 ms 13 14 IP65 -5725655980 97 ms 13 14 IP65 -5725655202 - - - Basic valve without pilot valveR412008098 - 13 14 - Basic valve without coilR412000127 97 ms 13 14 IP65 -R412000148 97 ms 13 14 IP65 -R412000149 97 ms 13 14 IP65 -R412000151 - - - Basic valve without pilot valveR412000224 97 ms 13 14 IP65 -R412000225 97 ms 13 14 IP65 -R412000230 97 ms 13 14 IP65 -R412000237 - - - Basic valve without pilot valve5725680220 97 ms 13 14 IP65 -5725685270 97 ms 13 14 IP65 -5725685280 97 ms 13 14 IP65 -5725685202 - - - Basic valve without pilot valveR412000219 97 ms 13 14 IP65 -R412000220 97 ms 13 14 IP65 -R412000221 97 ms 13 14 IP65 -R412000222 - - - Basic valve without pilot valveR412000153 97 ms 13 14 IP65 -R412000154 97 ms 13 14 IP65 -R412000157 97 ms 13 14 IP65 -R412000160 - - - Basic valve without pilot valve

Part No. Reverse polarity protection ATEX Weight

5725650220 Protected against polarity reversal - 1.3 kg -5725650920 Protected against polarity reversal - 1.3 kg 1)5725655270 Protected against polarity reversal - 1.3 kg -5725655280 Protected against polarity reversal - 1.3 kg -5725655980 Protected against polarity reversal - 1.3 kg 1)5725655202 - ATEX optional 1 kg -R412008098 - ATEX optional 1 kg 1)R412000127 Protected against polarity reversal - 1.3 kg -R412000148 Protected against polarity reversal - 1.3 kg -R412000149 Protected against polarity reversal - 1.3 kg -R412000151 - ATEX optional 1 kg -R412000224 Protected against polarity reversal - 1.3 kg -R412000225 Protected against polarity reversal - 1.3 kg -R412000230 Protected against polarity reversal - 1.3 kg -R412000237 - ATEX optional 1 kg -5725680220 Protected against polarity reversal - 1.3 kg -5725685270 Protected against polarity reversal - 1.3 kg -5725685280 Protected against polarity reversal - 1.3 kg -

PDF creation date: 20.06.2020

Page 37: Catalog AVENTICS Series CD12 - Emerson

Page 37 | AVENTICS

Part No. Reverse polarity protection ATEX Weight

5725685202 - ATEX optional 1 kg -R412000219 Protected against polarity reversal - 1.3 kg -R412000220 Protected against polarity reversal - 1.3 kg -R412000221 Protected against polarity reversal - 1.3 kg -R412000222 - ATEX optional 1 kg -R412000153 Protected against polarity reversal - 1.3 kg -R412000154 Protected against polarity reversal - 1.3 kg -R412000157 Protected against polarity reversal - 1.3 kg -R412000160 - ATEX optional 1 kg -

Nominal flow Qn at 6 bar and Δp = 1 bar, MO = Manual override1) Exhaust cap

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximumworking pressure is 10 bar.

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 38: Catalog AVENTICS Series CD12 - Emerson

Page 38 | AVENTICS

Dimensions

Dimensions

1) Valve plug connector 2) Coil can be rotated at 90° intervals 3) Manual override4) Port X, side 14 5) Port X, side 12 6) Port withoutfunction 7) Pilot valve exhaust, M5

PDF creation date: 20.06.2020

Page 39: Catalog AVENTICS Series CD12 - Emerson

Page 39 | AVENTICS

3/2-directional valve, Series CD12- Qn = 4000 l/min- Compressed air connection output G 1/2- Single air pilot- Pipe connection- suitable for ATEX

Version Spool valve, positive overlappingActivation pneumaticallySealing principle Soft sealingFlow rate value Qn 4000 l/minWorking pressure min./max. -0.95 ... 16 barControl pressure min./max. 2 ... 10 barAmbient temperature min./max. -25 ... 70 °CMedium temperature min./max. -25 ... 70 °CMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Weight 0.71 kg

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

5711100300 NC/NO G 1/2 G 1/2

Part No. Compressed air connection Compressed air connectionExhaust Pilot control exhaust

5711100300 G 1/2 G 1/8

Nominal flow Qn at 6 bar and Δp = 1 bar

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

PDF creation date: 20.06.2020

Page 40: Catalog AVENTICS Series CD12 - Emerson

Page 40 | AVENTICS

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

Dimensions

Dimensions

1) Port 12/102) vent port of piston

PDF creation date: 20.06.2020

Page 41: Catalog AVENTICS Series CD12 - Emerson

Page 41 | AVENTICS

3/2-directional valve, Series CD12- Qn = 4000 l/min- Compressed air connection output M22x1,5- Single air pilot- Pipe connection- suitable for ATEX

Version Spool valve, positive overlappingActivation pneumaticallySealing principle Soft sealingFlow rate value Qn 4000 l/minWorking pressure min./max. -0.95 ... 16 barControl pressure min./max. 2 ... 10 barAmbient temperature min./max. -25 ... 70 °CMedium temperature min./max. -25 ... 70 °CMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Weight 0.71 kg

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

5711100200 NC/NO M22x1,5 M22x1,5

Part No. Compressed air connection Compressed air connectionExhaust Pilot control exhaust

5711100200 M22x1,5 G 1/8

Nominal flow Qn at 6 bar and Δp = 1 bar

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

PDF creation date: 20.06.2020

Page 42: Catalog AVENTICS Series CD12 - Emerson

Page 42 | AVENTICS

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

Dimensions

Dimensions

1) Port 12/102) vent port of piston

PDF creation date: 20.06.2020

Page 43: Catalog AVENTICS Series CD12 - Emerson

Page 43 | AVENTICS

5/2-directional valve, Series CD12- Qn = 4100 l/min- Qn 1▶2 = 4100 l/min- Compressed air connection output G 1/2- Pipe connection- suitable for ATEX

Version Spool valve, positive overlappingActivation pneumaticallySealing principle Soft sealingFlow rate value Qn 4100 l/minWorking pressure min./max. -0.95 ... 16 barControl pressure min./max. 2 ... 10 barAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Weight 0.86 kg

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

5711000100 G 1/2 G 1/25711000300 G 1/2 G 1/25711001100 G 1/2 G 1/2

Part No. Compressed air connection Compressed air connection FlowExhaust Pilot control exhaust Qn 1▶2

5711000100 G 1/2 G 1/8 -5711000300 G 1/2 G 1/8 -5711001100 G 1/2 G 1/8 4100 l/min

Part No. Ambient temperature min./max. Medium temperature min./max. Fig.

5711000100 -25 ... 70 °C -25 ... 70 °C Fig. 25711000300 -15 ... 70 °C -15 ... 70 °C Fig. 15711001100 -25 ... 70 °C -25 ... 70 °C Fig. 2

Nominal flow Qn at 6 bar and Δp = 1 bar

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

PDF creation date: 20.06.2020

Page 44: Catalog AVENTICS Series CD12 - Emerson

Page 44 | AVENTICS

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

Dimensions

Fig. 1, Single air pilot

1) Port 142) Vent port of piston

PDF creation date: 20.06.2020

Page 45: Catalog AVENTICS Series CD12 - Emerson

Page 45 | AVENTICS

DimensionsFig. 2, double air pilot

1) Port 142) Port 123) Port without function

PDF creation date: 20.06.2020

Page 46: Catalog AVENTICS Series CD12 - Emerson

Page 46 | AVENTICS

5/2-directional valve, Series CD12- Qn = 4100 l/min- Compressed air connection output M22x1,5- Pipe connection- suitable for ATEX

Version Spool valve, positive overlappingActivation pneumaticallySealing principle Soft sealingFlow rate value Qn 4100 l/minWorking pressure min./max. -0.95 ... 16 barControl pressure min./max. 2 ... 10 barAmbient temperature min./max. See table belowMedium temperature min./max. See table belowMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Weight 0.86 kg

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

5711000000 M22x1,5 M22x1,5R412013343 M22x1,5 M22x1,5R412013344 M22x1,5 M22x1,5

Part No. Compressed air connection Compressed air connectionExhaust Pilot control exhaust

5711000000 M22x1,5 G 1/8R412013343 M22x1,5 G 1/8R412013344 M22x1,5 G 1/8

Part No. Ambient temperature min./max. Medium temperature min./max. Fig.

5711000000 -25 ... 70 °C -25 ... 70 °C Fig. 2R412013343 -15 ... 70 °C -15 ... 70 °C Fig. 1R412013344 -25 ... 70 °C -25 ... 70 °C Fig. 2

Nominal flow Qn at 6 bar and Δp = 1 bar

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

PDF creation date: 20.06.2020

Page 47: Catalog AVENTICS Series CD12 - Emerson

Page 47 | AVENTICS

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

Dimensions

Fig. 1, Single air pilot

1) Port 142) Vent port of piston

PDF creation date: 20.06.2020

Page 48: Catalog AVENTICS Series CD12 - Emerson

Page 48 | AVENTICS

DimensionsFig. 2, double air pilot

1) Port 142) Port 123) Port without function

PDF creation date: 20.06.2020

Page 49: Catalog AVENTICS Series CD12 - Emerson

Page 49 | AVENTICS

5/3-directional valve, Series CD12- Qn 1▶2 = 3600-4100 l/min- Qn 2▶3 = 3800-4100 l/min- Compressed air connection output G 1/2- Pipe connection- suitable for ATEX

Version Spool valve, positive overlappingActivation pneumaticallySealing principle Soft sealingCompressed air connection according to ISO 228-1Working pressure min./max. -0.95 ... 16 barControl pressure min./max. 3 ... 10 barAmbient temperature min./max. -25 ... 70 °CMedium temperature min./max. -25 ... 70 °CMedium Compressed airMax. particle size 50 µmOil content of compressed air 0 ... 1 mg/m³Weight 0.95 kg

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

5711200050 closed center G 1/2 G 1/25711200060 - G 1/2 G 1/2R414002380 - G 1/2 G 1/2

Part No. Compressed air connection Compressed air connection Flow FlowExhaust Pilot control exhaust Qn 1▶2 Qn 2▶3

5711200050 G 1/2 G 1/8 3800 l/min 3800 l/min5711200060 G 1/2 G 1/8 3600 l/min 4100 l/minR414002380 G 1/2 G 1/8 4100 l/min 3800 l/min

Nominal flow Qn at 6 bar and Δp = 1 bar

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

Technical information

Material

Housing Aluminum Polyamide fiber-glass reinforced

Seals Acrylonitrile butadiene rubber Polyurethane

PDF creation date: 20.06.2020

Page 50: Catalog AVENTICS Series CD12 - Emerson

Page 50 | AVENTICS

Dimensions

Fig. 2, double air pilot

1) Port 142) Port 123) Port without function

PDF creation date: 20.06.2020

Page 51: Catalog AVENTICS Series CD12 - Emerson

Page 51 | AVENTICS

Valve plug connector, series CON-VP- Socket, 2+E, angled, 90°- EN 175301-803- unshielded- with LED Yellow Red

Connection type ScrewsAmbient temperature min./max. -40 ... 90 °COperationalvoltage

See table below

Protection class IP65Mounting screw tightening torque 0.4 NmWeight See table below

Technical data

Part No. Operationalvoltage

Protective circuit Contact assignment LED status display

1834484101 24 V AC/DC Z-diode 2+E Yellow1834484102 110 V AC Varistor 2+E Red1834484103 230 V AC Varistor 2+E Red

Part No. suitable cable-Ø min./max Seal Weight

1834484101 6 / 8 mm Silicone caoutchouc 0.03 kg 1)1834484102 6 / 8 mm caoutchouc/butadiene caoutchouc 0.03 kg 2)1834484103 6 / 8 mm Silicone caoutchouc 0.025 kg 2)

1) Flat gasket2) Profile seal

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Seals Silicone caoutchouc caoutchouc/butadiene caoutchouc

PDF creation date: 20.06.2020

Page 52: Catalog AVENTICS Series CD12 - Emerson

Page 52 | AVENTICS

Dimensions

Dimensions

1) Max.

PDF creation date: 20.06.2020

Page 53: Catalog AVENTICS Series CD12 - Emerson

Page 53 | AVENTICS

Valve plug connector, series CON-VP- Socket, 2+E, angled, 90° Socket, 3+E, angled, 90°- EN 175301-803- unshielded

Connection type ScrewsAmbient temperature min./max. -40 ... 90 °CProtection class IP65Mounting screw tightening torque 0.4 NmWeight 0.03 kg

Technical data

Part No. Electrical connection Max. current Contactassignment

suitable cable-Ø min./max1

1834484048 Socket 2+E angled 90° 10 A 2+E 6 / 8 mm1834484059 Socket 3+E angled 90° 10 A 3+E 6 / 8 mm

Profile seal

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Seals caoutchouc/butadiene caoutchouc

PDF creation date: 20.06.2020

Page 54: Catalog AVENTICS Series CD12 - Emerson

Page 54 | AVENTICS

Dimensions

Dimensions

1) Max.

PDF creation date: 20.06.2020

Page 55: Catalog AVENTICS Series CD12 - Emerson

Page 55 | AVENTICS

Valve plug connector, series CON-VP- Socket form A 2+E angled 90°- open cable ends 3-pin- with cable- unshielded

Ambient temperature min./max. -20 ... 80 °COperationalvoltage

See table below

Protection class IP67Wire cross-section 0.75 mm²Mounting screw tightening torque 0.4 NmWeight See table below

Technical data

Part No. Operationalvoltage

Protective circuit Contactassignment

LED status display

1834484160 230 V AC/DC - 2+E -1834484162 24 V AC/DC Z-diode 2+E Yellow1834484163 24 V AC/DC Z-diode 2+E Yellow1834484164 230 V AC/DC Varistor 2+E Red1834484165 230 V AC/DC Varistor 2+E Red

Part No. Number of wires Cable-Ø Cable length Weight Fig.

1834484160 3 5.9 mm 3 m 0.2 kg Fig. 1 1)1834484162 3 5.9 mm 3 m 0.2 kg Fig. 2 -1834484163 3 5.9 mm 5 m 0.31 kg Fig. 2 -1834484164 3 5.9 mm 3 m 0.2 kg Fig. 2 -1834484165 3 5.9 mm 5 m 0.31 kg Fig. 2 -

1) Scope of delivery incl. flat gasket

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Seals caoutchouc/butadiene caoutchouc

Cable sheath Polyvinyl chloride

PDF creation date: 20.06.2020

Page 56: Catalog AVENTICS Series CD12 - Emerson

Page 56 | AVENTICS

Dimensions

Fig. 1

PDF creation date: 20.06.2020

Page 57: Catalog AVENTICS Series CD12 - Emerson

Page 57 | AVENTICS

DimensionsFig. 2

PDF creation date: 20.06.2020

Page 58: Catalog AVENTICS Series CD12 - Emerson

Page 58 | AVENTICS

Coil, Series CO1- form A- Coil width 30 mm- Power consumption DC 2.7 W- Holding power AC 4.8-5.6 VA

Connector standard EN 175301-803, form Aelectrical connections Plug, 3-pinAmbient temperature min./max. 50 °CProtection class With valve plugconnector/plug

IP65

Duty cycle ED 100 %Compatibility index 14Weight 0.096 kg

Technical data

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz5420897022 24 V - -5428117022 - 24 V 24 V5428117072 - 110 V 110 V5428117082 - 230 V 230 V

Part No. Voltage tolerance Voltage tolerance Voltage tolerance Power consumptionDC AC 50 Hz AC 60 Hz DC

5420897022 -10% / +10% - - 2.7 W5428117022 - -20% / +10% -10% / +20% -5428117072 - -20% / +10% -10% / +20% -5428117082 - -20% / +10% -10% / +20% -

Part No. Holding power Holding powerAC 50 Hz AC 60 Hz

5420897022 - -5428117022 5.2 VA 3.9 VA5428117072 4.8 VA 3.6 VA5428117082 5.6 VA 4.2 VA

PDF creation date: 20.06.2020

Page 59: Catalog AVENTICS Series CD12 - Emerson

Page 59 | AVENTICS

Technical information

Material

Housing Thermoplastic elastomer

Dimensions

Dimensions

PDF creation date: 20.06.2020

Page 60: Catalog AVENTICS Series CD12 - Emerson

Page 60 | AVENTICS

Coil, Series CO1- Cable with valve plug connector- Coil width 30 mm- Power consumption DC 3.25 W- Holding power AC 2.9-3 VA- Switch-on power AC 3-3.1 VA- ATEX

Certificates ATEXATEX class G II 2G Ex mb IIC T4 GbATEX class D II 2D Ex mb tb IIIC T130°C Db IP65Ambient temperature min./max. -20 ... 50 °CProtection class IP65Duty cycle ED 100 %Compatibility index 14Weight See table below

Technical data

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz1827414297 - 230 V 230 V1827414298 - 230 V 230 V1827414299 - 110 V 110 V1827414301 - 24 V 24 V1827414303 24 V - -1827414304 24 V - -

Part No. Voltage tolerance Voltage tolerance Power consumption Holding powerDC AC 50 Hz DC AC 50 Hz

1827414297 - -10% / +10% - 3 VA1827414298 - -10% / +10% - 3 VA1827414299 - -10% / +10% - 2.9 VA1827414301 - -10% / +10% - 2.9 VA1827414303 -10% / +10% - 3.25 W -1827414304 -10% / +10% - 3.25 W -

Part No. Switch-on power Cable length WeightAC 50 Hz

1827414297 3.1 VA 3 m 0.38 kg

PDF creation date: 20.06.2020

Page 61: Catalog AVENTICS Series CD12 - Emerson

Page 61 | AVENTICS

Part No. Switch-on power Cable length WeightAC 50 Hz

1827414298 3.1 VA 10 m 0.91 kg1827414299 3 VA 3 m 0.38 kg1827414301 3 VA 3 m 0.38 kg1827414303 - 3 m 0.38 kg1827414304 - 10 m 0.91 kg

Dimensions

Dimensions

L = cable length1) Cable ID band with serial number

PDF creation date: 20.06.2020

Page 62: Catalog AVENTICS Series CD12 - Emerson

Page 62 | AVENTICS

Silencers, series SI1- G 1/2- Sintered bronze

Working pressure min./max. 0 ... 10 barAmbient temperature min./max. -25 ... 80 °CMedium Compressed airSound pressure level 90 dBWeight 0.08 kgComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000003 G 1/2 7223 l/min 2 piece

Weight per pieceNominal flow Qn at p1 = 6 bar (absolute) freely discharged. Sound pressure level measured at 6 bar against atmosphere at 1 mdistance.

Technical information

Material

Silencer Sintered bronze

Thread Brass

PDF creation date: 20.06.2020

Page 63: Catalog AVENTICS Series CD12 - Emerson

Page 63 | AVENTICS

Dimensions

Dimensions in mm

Diagrams

Flow diagram, 1827000003

PDF creation date: 20.06.2020

Page 64: Catalog AVENTICS Series CD12 - Emerson

Page 64 | AVENTICS

Silencers, series SI1- G 1/2- Polyethylene

Working pressure min./max. 0 ... 10 barAmbient temperature min./max. -25 ... 80 °CMedium Compressed airSound pressure level 88 dBWeight 0.013 kg

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000022 G 1/2 7142 l/min 1 piece

Weight per pieceNominal flow Qn at p1 = 6 bar (absolute) freely discharged. Sound pressure level measured at 6 bar against atmosphere at 1 mdistance.

Flow characteristic curves can be found under “Diagrams”.

Technical information

Technical information

Material

Silencer Polyethylene

Thread Polyethylene

PDF creation date: 20.06.2020

Page 65: Catalog AVENTICS Series CD12 - Emerson

Page 65 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G Ø D L1 L2

1827000022 G 1/2 23.3 66.5 11

Diagrams

Flow diagram, 1827000018

PDF creation date: 20.06.2020

Page 66: Catalog AVENTICS Series CD12 - Emerson

Page 66 | AVENTICS

DiagramsFlow diagram, 1827000019

DiagramsFlow diagram, 1827000020

DiagramsFlow diagram, 1827000021

PDF creation date: 20.06.2020

Page 67: Catalog AVENTICS Series CD12 - Emerson

Page 67 | AVENTICS

DiagramsFlow diagram, 1827000022

DiagramsFlow diagram, 1827000023

DiagramsFlow diagram, 1827000024

PDF creation date: 20.06.2020

Page 68: Catalog AVENTICS Series CD12 - Emerson

Page 68 | AVENTICS

Silencers, series SI1- G 1/2- Sintered bronze

Working pressure min./max. 0 ... 10 barAmbient temperature min./max. -25 ... 80 °CMedium Compressed airSound pressure level 85 dBWeight 0.035 kgComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000035 G 1/2 2568 l/min 2 piece

Weight per pieceNominal flow Qn at p1 = 6 bar (absolute) freely discharged. Sound pressure level measured at 6 bar against atmosphere at 1 mdistance.

Technical information

Material

Silencer Sintered bronze

Thread Brass

PDF creation date: 20.06.2020

Page 69: Catalog AVENTICS Series CD12 - Emerson

Page 69 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G L1 L2 SW

1827000035 G 1/2 12 19.5 27

Sound pressure level measured at 6 bar at 1 m distance

Diagrams

Flow diagram, 1827000032

PDF creation date: 20.06.2020

Page 70: Catalog AVENTICS Series CD12 - Emerson

Page 70 | AVENTICS

DiagramsFlow diagram, 1827000031

DiagramsFlow diagram, 1827000033

DiagramsFlow diagram, 1827000034

PDF creation date: 20.06.2020

Page 71: Catalog AVENTICS Series CD12 - Emerson

Page 71 | AVENTICS

DiagramsFlow diagram, 1827000035

DiagramsFlow diagram, 8145003400

DiagramsFlow diagram, 8145001000

PDF creation date: 20.06.2020

Page 72: Catalog AVENTICS Series CD12 - Emerson

Page 72 | AVENTICS

Silencers, series SI1- G 1/2- Sintered bronze

Working pressure min./max. 0 ... 10 barAmbient temperature min./max. -25 ... 80 °CMedium Compressed airComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

R412007876 G 1/2 1343 l/min 2 piece

Nominal flow Qn at p1 = 6 bar (absolute) freely discharged. Sound pressure level measured at 6 bar against atmosphere at 1 mdistance.

Technical information

Material

Silencer Sintered bronze

Thread Brass

PDF creation date: 20.06.2020

Page 73: Catalog AVENTICS Series CD12 - Emerson

Page 73 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G Ø D Ø D1 H L

R412007876 G 1/2 15 12 5 9

Diagrams

Flow diagram, 1827430004

PDF creation date: 20.06.2020

Page 74: Catalog AVENTICS Series CD12 - Emerson

Page 74 | AVENTICS

DiagramsFlow diagram, R414000155

DiagramsR412007875

DiagramsFlow diagram, R412007876

PDF creation date: 20.06.2020

Page 75: Catalog AVENTICS Series CD12 - Emerson

Page 75 | AVENTICS

DiagramsFlow diagram, R412007877

DiagramsFlow diagram, R412007878

PDF creation date: 20.06.2020

Page 76: Catalog AVENTICS Series CD12 - Emerson

Efficient pneumatic solutions, our program:cylinders and drives, valves and valve systems,air supply management

Visit us: Emerson.com/Aventics

Your local contact: Emerson.com/contactus

Emerson.com

Facebook.com/EmersonAutomationSolutions

LinkedIn.com/company/Emerson-Automation-Solutions

Twitter.com/EMR_Automation

An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. ThisDocument, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS GmbH. It may not bereproduced or given to third parties without its consent. Only use the AVENTICS products shown in industrial applications. Read the productdocumentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. Whenintegrating the product into applications, note the system manufacturer’s specifications for safe use of the product. The data specified only servetodescribe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information.The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products aresubject to a natural process of wear and aging.

The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand logotype are registered trademarks of oneof the Emerson family of companies. All other marks are the property of their respective owners. © 2017 Emerson Electric Co.All rights reserved.2019-03