blowers manufacturer and supplier in usa - leading the way … · 2018. 5. 17. · largest roots...

21
Engineering Evaluation Designing Manufacturing Testing Execution Post Sales & Service APPLICATIONS Water Treatment Plants for backwashing of filter/mixed beds Effluent Treatment Plants for diffused aeration and agitation of effluent Sewage Treatment Plants for diffused aeration and agitation of sewage Cement Plants for blending, aeration, fluidization and conveying Aquaculture for maintaining the dissolved oxygen level Chemical Plants for supply of process air Electroplating Plants for oil free air agitation of electrolyte Paper Plants for knife edge coating, drying, conveying and vacuum pickup Yarn Drying for vacuum/pressure drying Polyester Chip Conveying & Drying for transfer of polyester chips and other similar materials Bag Filters for reverse cleaning of filter bags Pneumatic Conveying for vacuum, pressure and combination conveying of cereals, cement, husk, baggase, granules, powders and other similar material Regeneration of Dryers & Molecular Sieves FGD - Flue Gas Desulpharization VPSA - Vacuum Pressure Swing Adsorbtion Customer Support T: +1-949-269-1472 | E: [email protected] EVEREST USA Office 13217 Jamboree Road, Suite 482, Tustin, CA 92782, USA Group Companies Tf: +1-949-269-1472 | E: [email protected] PRESSURE & VACUUM SYSTEMS Everest Blowers Pvt. Ltd. - Everest Transmission - Everest Blower Systems Pvt. Ltd. Package Blower Systems | Revision 1 | January 2017 www.everestblowers.us Leading the way for INNOVATIVE SOLUTIONS EVEREST PRESSURE & VACUUM SYSTEMS PACKAGE BLOWER SYSTEMS TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS ACOUSTIC HOODS | ENCLOSURES Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Upload: others

Post on 22-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

EngineeringEvaluationDesigningManufacturingTestingExecutionPost Sales & Service

APPLICATIONS

Water Treatment Plants for backwashing of filter/mixed beds

Effluent Treatment Plants for diffused aeration and agitation of effluent

Sewage Treatment Plants for diffused aeration and agitation of sewage

Cement Plants for blending, aeration, fluidization and conveying

Aquaculture for maintaining the dissolved oxygen level

Chemical Plants for supply of process air

Electroplating Plants for oil free air agitation of electrolyte

Paper Plants for knife edge coating, drying, conveying and vacuum pickup

Yarn Drying for vacuum/pressure drying

Polyester Chip Conveying & Drying for transfer of polyester chips and other similar materials

Bag Filters for reverse cleaning of filter bags

Pneumatic Conveying for vacuum, pressure and combination conveying of cereals, cement, husk, baggase,

granules, powders and other similar material

Regeneration of Dryers & Molecular Sieves

FGD - Flue Gas Desulpharization

VPSA - Vacuum Pressure Swing Adsorbtion

Customer SupportT: +1-949-269-1472 | E: [email protected]

EVEREST USA Office

13217 Jamboree Road, Suite 482, Tustin, CA 92782, USAGroup Companies

Tf: +1-949-269-1472 | E: [email protected] & VACUUM SYSTEMS Everest Blowers Pvt. Ltd. - Everest Transmission - Everest Blower Systems Pvt. Ltd.

Package Blower Systems | Revision 1 | January 2017 www.everestblowers.us

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

PACKAGE BLOWER SYSTEMSTWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS

ACOUSTIC HOODS | ENCLOSURES

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 2: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Everest Group Mission Vision

Provider of Innovative To become top solutionengineering solutions in provider of Pressure &entire range of pressure & Vacuum Systems in India,vacuum systems by having setting benchmarks ofstate of art technology, performance and providingoptimized designs, value for customers.excellence in R&D,manufacturing and thruston training & developmentof employees, continuouslyexpanding our operations.

Quality Policy Quality Objectives Core Values

We at Everest are • Delivery on time, delivery • Customer Focuscommitted to continually in full, of defect free • Respect for Individualsimprove in all process products • Integrityareas leading to quality • Wastage reduction • Strong Relationshipsproduct by involving • Introducing New/ • Passion & Drivecompetent and motivated upgraded products • Institution Buildingemployees at all levels better than the • Working Togetherleading to overall growth of competitor, meetingthe company through customers' expectationssatisfied customers. • Cost reduction by Value

Engineering/ othermethods

• Timely and effectivecustomer support &services

• Achieving and sustainingsuperior levels ofperformance in alloperations

• Up gradation ofinfrastructure

• Human resourcesdevelopment

Page 3: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

ABOUT US

A focus on

innovativedesign and high

qualitymachined parts

has earnedEverest a

reputation forexcellent

workmanshipamongst its users.

For more than three

decades Everest has

offered its customers

quality, cost-effective

machines necessary

to meet the changing

technology

VEREST commenced manufacturing of Twin Lobe Rotary Air Blowers Ewayback in 1980. Since then the company has consistently strengthened its

manufacturing base, producing a wide range of products. This broad productline includes Twin Lobe & Tri-Lobe Rotary Air Blowers / Compressors

(Roots Blowers), Mechanical Vacuum Boosters, Dry Screw Vacuum Pumps,

Acoustic Hoods & Industrial Vacuum Systems.These wide-ranging products

and the technical expertise gained over the years have enabled Everest to serve

various segments of industry such as water treatment plants, effluent treatment

plants, cement plants, aquaculture farms, chemical & pharmaceutical plants,

food processing units, waste oil re-refining units, paper plants, vacuum plants

and systems and pneumatic conveying systems.

The blowers find use in applications requiring medium pressure air such as

aeration in sewage treatment and effluent treatment plants, filter backwash,

agitation of electrolyte, pneumatic conveying, regeneration of dryers &

molecular sieves, maintaining BOD of water etc.

The mechanical vacuum booster & Dry Screw Vacuum Pumps, a sophisticated piece

of machinery developed by the company, finds use in chemical and pharmaceutical

processes, bulb and tube light production, waste oil re-refining, roll and object

metallizing, vegetable oil deodorization, solvent recovery, vacuum drying, tray

drying, vacuum distillation, thin film deposition, molecular distillation, vacuum

furnace, transformer oil dehumidification, chemical laser, evaporative cooling etc.

Apart from above standard products Everest is also into a lot of customized

products which include various specialized equipment to meet the specific demands

such as Canned Motor Mechanical Vacuum Boosters especially developed for BARC

for research applications, Helium and CO2 duty blowers for Nuclear Power

Corporation, Petrol engine driven aluminium alloy blowers for thermit welding of

rails for Indian Railways, 100% Oil Free blowers for fish and prawn culture, etc.

Everest is also into supply of complete systems for special applications such as Vacuum

Distillation, Vacuum Drying (Vacuum Tray Dryers, Rotary Cone Vacuum Dryers, etc),

Solvent Recovery,Waste Oil Re-refining etc. which are commonly used in Food

Processing, Pharmaceutical & Chemical Industries. Everest also offers 100%

TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS

ACOUSTIC HOODS | ENCLOSURES

Engineering

EvaluationDesigningManufacturingTestingExecution

Dry Vacuum Systems having no requirement of Steam, Water or Oil. This leads to Post Sales & Servicezero effluent / zero discharge of any harmful gases inside the plant, thus maintaining

high level of product quality and maintaining pollution free environment.

Some of our prestigious clients include NIOT, Indian Space Research Organization,

Centre for Advanced Technology, BARC, Mishra Dhatu Nigam, NTPC, Ion

Exchange (India) Ltd., Thermax, Aurobindo Pharma, KLJ, Wockhardt, VA Tech

Wabag, Maruti Udyog, Honda Siel, Hero Honda, Grasim Industries, Cadbury, LG

Polymers, Heinz, Vam Organics, Smithklime Beecham, Cipla, DSM, Hereto Drugs,

IOCL, GAIL, EIL, BHEL, Grasim, ACC, Tata Steel, Jindal Steel, McNally Bharat,

Jindal Saw and many more.

We are concentrating more on application engineering and in helping our

customer's save on their processes.This innovation has not only compensated on our

general sales but even helped us to outperform on our targets. Our application

oriented R&D has made it possible to cover wider areas of applications, offering cost

effective and energy efficient solutions thus creating larger market demand for our

product.

A focus on innovative design and high quality machined parts has earned Everest a

reputation for excellent workmanship amongst its users. For more than three

decades Everest has offered its customers quality, cost-effective machines necessary to

meet the changing technology. Our commitment to total quality in both our

products and services is the foundation upon which our future business is based.

Some of Our Recent Achievements

Design & manufacture of seal less Roots Blowers

Design & manufacture of solvent recovery systems to curb pollution.

These systems not only play an important role by making the process

eco-friendly but also recover precious solvents for reuse.

Design & manufacture of CPCB approved systems for waste oil re-refining.

Design & manufacture of mechanical vacuum boosters for

replacement of steam jet ejectors.

Design & manufacture of SUPERVAC vacuum systems using mechanical

Page 4: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

ABOUT US vacuum boosters and dry screw vacuum pumps - Dry Pumping Technology.

Design & manufacture of extended shaft Roots Blowers for

applications requiring 100% Oil Free Air like aeration in

aquaculture farms, plating lines, STPs, etc.

Design and manufacture of canned motor mechanical vacuum boosters

Design & manufacture of India's first MVR (Mechanical Vapour

Recompression) Blower successfully put to use.

Design & manufacture of Low Temperature Thermal Desalination

systems for producing potable water ……… and many more.

We have plans of setting up the most modern manufacturing facility with in

house DSIR registered R&D facility which would not only role out good

reliable products but also assist in meeting the targeted expansion program.

Everest is the first and the only Indian Blower manufacturer to have successfully

shifted entire production load of its blowers, boosters & pumps on CNC machines.

The company has imported a number of sophisticated CNC machines from USA &

Japan, resulting in higher production capacities & better quality. Everest is today the

largest Roots Blower manufacturer in the country and a leader in its segment.

Broad Product Line Serves Wide Variety of Applications

We know that performance of the OEM's design ultimately depends on the

quality and dependability of its components. That's why so many

manufacturers of Water Treatment Plants, Effluent Treatment Plants, Cement

Plants, Aquaculture Farms, Chemical Plants, Paper Plants, Vacuum Plants and

Systems, and Pneumatic Conveying Systems have entrusted their reputation to

Everest. Our broad product line of Roots Blowers/Compressors (Bi-lobe & Tri-

lobe) (Air/Gas Duty), Mechanical Vacuum Boosters, Dry Screw Vacuum Pumps,

Acoustic Hoods & Industrial Vacuum Systems consists of standard and custom

models that fall into major product group.

Our Commitment To Quality | ISO 9001:2015

The hallmark of our commitment to quality is our International

Standards Organisation (ISO) registration. This ensures that our

OEM customers receive products of highest quality.

TIMELINE1980Set up 'EVEREST TRANSMISSION' to manufacture Twin Lobe Rotary Air Blowers /Compressors for industries related to cement, chemicals, water & waste water treatment, effluent treatment, electroplating, aqua culture, etc.1985Chosen as a priority vendor by BHEL and entire Quality Management System designed and implemented with the help of Vendor Development Cell of BHEL.1985-1995Bagged prestigious orders from Industry giants like NTPC, Ion Exchange (India) Ltd., Thermax, Bechtel, Daelim, Mitsubishi Heavy Industries, BHEL, Tata Projects, Toyo Engineering, ONGC, Holtec Consultants, IPCL, SGS, Degremont, Driplex, DevelopmentConsultants, Grindwell Norton, Triveni Engineering, VA Tech Wabag, etc.

1993Import substitute Mechanical Vacuum Booster developed and introducedto Indian market for vacuum metallizing, sputtering, space research, etc.1995Set up 'EVEREST BLOWERS' to cater to the growing demand of small rootsblowers up to 15 HP.1998Certified ISO 9001 Quality Management System by DNV, Norway.1999Introduced AQUA Series Air Blowers specially crafted for fish and prawn culture and electroplating applications. New Water Cooled Blower design introduced.

2000Met the technical requirements of the Research Cell of Department Of Atomic Energy, CAT, Indore for supply of Mechanical Vacuum Boosters for Chemical Laser Division. Developed Model M450, EB6HPM, & M5 Series Air Blowers.2001Began exporting our Mechanical Vacuum Booster Pumps to advanced countries such as USA, Singapore and Middle East against stiff global competition.

2002Dry Vane Pumps introduced and expansion of exports to Singapore, UK, Australia, UAE, Iraq, Maldives, Sri Lanka, Vietnam, Nepal, Bhutan, and Bangladesh.

2003EXPO Series Air Blowers developed.2004Developed Extended Shaft Design Air Blowers. Introduced Mechanical Vacuum Boosters in the Indian Pharmaceutical & Chemical Industry and for waste oil re-refining. Successfully designed, manufactured & supplied vacuum drying systems to Cadbury India Limited. 2005Vacuum Systems supplied to National Institute Of Ocean Technology for 0.1 MLD Low Temperature Thermal Desalination (LTTD) Pilot Plant for producing potable water First ofits kind in the world. Successfully installed at Kavaratti in Lakshadweep, India. Mechanical Vapor Recompression Systems successfully developed & installed.

2006Successfully designed, manufactured & supplied World's First 1 MLD Low Temperature Thermal Desalination (LTTD) system for producing potable drinking waterto National Institute of Ocean Technology, Chennai, India. Introduced Back Flow Cooling Rotary Air Blowers for VPSA ( Vacuum Pressure Swing Adsorption) system.

2007Set up 'EVEREST BLOWER SYSTEMS' to cater to the demands of Industrial Vacuum Systems & Dry Vacuum Pumping technology.2008Introduced Dry Screw Vacuum Pumps. Introduced Dry Vacuum Pumping Systems for Waste Oil Re-refining.2009Complete manufacturing shifted over to CNC machines imported from Haas, USA. Introduced Everest Super Sucker 4000. Introduced Vacuum Pumping Systems for Solvent Recovery & Vacuum Distillation. Successfully designed, manufactured & supplied vacuum drying systems to Cadbury Nigeria.2010Developed & introduced Vertical Tri-lobe Roots Blower Model ETL025. Introduced Everest Super Sucker 6000.2011Manufacturing facility at Everest Blowers, Bahadurgarh completely revampedfor enhanced production capability of 1000 machines per month.2012Tie up with LOT Vacuum, Korea for sales of Dry Screw Vacuum Pumps & Systems for

Semi-Conductor & Solar Industry. Introduced Dry ScrewVacuum Pumps with Hybrid Screw Design. Initiated Business Excellence exercise at Everest Group. Developed &introduced complete range of Tri-Lobe Roots Blowers.

2013R&D Facility at Everest Blowers awarded recognition by Department Of Scientific & Industrial Research, Ministry Of Science & Technology, Government Of India. AwardedDelhi Safety Awards 2013 by Government Of National Capital Territory Of Delhi. Manufacturing facility at New Delhi revamped and additionalCNC machines added from Haas, USA for capacity enhancement. 2014Everest Blowers Systems shiftedto new world class facility. Everest Group awarded National Award for Excellence in R&D from Prime Minister of India. Everest Transmission received prestigious orders from Nuclear Power Corporation of India for supply of Helium & Carbon Dioxide Blowers and repeat order from Le Sueur Bioenergy, Minnesota, USA for supply for Bio-gas Blowers. Production capacity enhancement at EBPL with induction of advanced CNC machines from Haas, USA.

2015Dealers appointed in Middle East Singapore for export promotion.

New facility procured for Pressure

Division. Everest Group plans to

come out with a state-of-the-art world

class facility for manufacturing of PD

Blowers

Mechanical Vacuum Boosters at this facility. Developed new line of Mechanical Vapour Recompressors.

2016New world class production facility started for manufacturingof PD Blowers & Mechanical Vacuum Boosters. Everest Group receives National Award for Energy Efficient Pumps. Everest Group introduces High Speed Single Stage Centrifugal Blowers (Turbo Blowers) and Multistage Centrifugal Blowers. Mr. Amit Kapur awarded Everything About Water Hall Of Fame Award. QMS upgraded to ISO 9001:2015 standard.

Page 5: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

PackageBlower Systems

TWIN-LOBE ROTARY AIR BLOWERS TRI-LOBE ROTARY AIR BLOWERS TRI-LOBE VERTICAL ROTARY AIR BLOWERS TWIN LOBE ROTARY GAS BLOWERS ACOUSTIC HOODS | ENCLOSURES

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 6: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Industries Served

Aerospace

Agriculture

Fishing Industry

Timber Industry

Tobacco Industry

Aquaculture

Chemical

Pharmaceutical

Construction

Energy

Electrical

Power Industry

Petroleum Industry

Oil & Gas

• Food Industry

• Dairy

• Food Processing

• Breweries & Distillery

• Manufacturing

• Pulp & Paper

• Steel

• Textiles

• Cement

• Water Industry

Biotechnology

Metals & Mining

FGD - Flue Gas

Desulpharization

VPSA - Vacuum Pressure

Swing Adsorbtion

Page 7: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Effective sealing ofthe compressor

inlet area from thedischarge area isaccomplished byuse of very small

operationalclearance,

eliminating theneed of any internal

lubrication of thelobes. The air

delivered, thusis 100% OIL

FREE

44 EVEREST | AIR COOLED

PACKAGE BLOWER SYSTEMS

TWIN-LOBE ROTARY AIR BLOWERSVEREST, a leading manufacturer of Roots Blowers in India, offers a

Ecomplete range of Twin Lobe Rotary Air Blowers (Roots Blowers), available for

flow rates from 25m3/hr to 20,000 m3/hr in single stage and upto any capacity inparallel configuration, for working pressures upto 1 Kg/cm2. They are

available as package units, ready to install or as bare blower units for replacement.

WORKING PRINCIPLE

POSITION-1 POSITION-2 POSITION-3 POSITION-4

Everest Twin Lobe Rotary Compressors/Blowers are positive displacement units, whose

pumping capacity is determined by size, operating speed and pressure conditions. It

employs two Twin Lobe impellers mounted on parallel shafts, rotating in opposite

direction within a casing closed at the ends by side plates. As the impellers rotate, air is

drawn into one side of the casing and forced out of the opposite side against the existing

pressures. The differential pressure developed, therefore, depends upon the resistance of

the connected system. The Blowers, being positive displacement type, do not develop

pressure within the casing but the discharge pressure depends upon the system

resistance / back pressure. Effective sealing of the compressor inlet area from the

discharge area is accomplished by use of very small operational clearance, eliminating

the need of any internal lubrication of the lobes. A pair of accurately machined alloy steel,

hardened and ground timing gears maintain clearances between the impellers, during

rotation.The air, thus delivered, is 100% OIL FREE. The pumping capacity of a lobe

compressor, operating at constant speed remains relatively independent of inlet and

discharge pressure variations. These Blowers are constant volume machines, which

deliver a fixed discharge against the system back pressure. It is, therefore, essential to

ensure that minimum pipeline restrictions, at the inlet and discharge, are imposed.

Adequate size piping and large radius bends ensure minimum line losses resulting in

higher efficiency and low power consumption. Sudden change in pipeline cross section

should also be avoided. To change capacity, it is necessary either to change speed

(energy saving) or vent some of the air into atmosphere (not energy saving).The air must

not be recirculated from the discharge to suction as it may result in overheating. No

attempt should ever be made to control the capacity of compressor by means of throttle

valves in the intake or discharge piping. This increases the power load on the motor and

may seriously damage the compressor. There is an increase in the discharge air

temperature due to heat of compression. As a thumb rule the discharge air temperature

increases @ 100C for every 0.1 Kg/cm2 of P above the inlet temperature.

TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORSTRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS

ACOUSTIC HOODS | ENCLOSURES

Everest Blowers areavailable aspackage units,ready to installor as bare blower

FEATURES units for replacement

100% oil free air delivery

Factory engineered, Factory guaranteed, superior product

Alloy steel hardened and ground timing gears, oil splash lubricated

Anti-friction bearings

Rotary Oil Sealing

Rigid one piece CI casing & end plates

Horizontal &Vertical configurations available

Easy rotor timing setting

Air Cooled & Water Cooled design available

Fail safe labyrinth sealing

Extended shaft design for cool running

Dynamically balanced rotor shaft assembly (Grade 6.3 ISO 1940-1986)

Large inlet & outlet connections for minimal loss

Improved volumetric efficiency and reduced operating temperatures

Alloy steel toughened shafts ground to close tolerances

Performance testing as per standard test procedure STP-01 based on BS 1571-2:1975 and ISO 1217:2009

All blowers are manufactured on state of the art, imported CNC machines, machined to close

tolerances with high degree of accuracy on profile machining, ensuring high volumetric efficiency

All major components are interchangeable making Everest the first and only manufacturer to attain the same

Non-contact type labyrinth seals, with vent , offers lifelong sealing without any seal replacement need

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 8: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL M450

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 45 0.5 34 0.8 25 1.0 18 1.3 12 1.6 6 1.8 1 2.1

1000 75 0.7 64 1.1 56 1.5 49 1.8 42 2.2 36 2.6 31 3.0

1400 116 1.0 105 1.5 96 2.1 89 2.6 83 3.1 77 3.6 72 4.1

1800 157 1.3 146 2.0 137 2.7 130 3.3 124 4.0 118 4.7 113 5.3

2100 187 1.5 176 2.3 168 3.1 161 3.9 154 4.7 149 5.4 143 6.2

2400 207 2.6 198 3.5 191 4.4 185 5.3 179 6.2 174 7.1

2700 210 7.0 205 8.0

Blower Opening: 46 mm; Standard recommended line size: 40 mmNB; Horizontal Flow Configuration; Suitable for Air Duty, Pressure Applications only; Air Cooled Version Only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 42

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 47 0.5 37 0.8 30 1.0 23 1.3 17 1.6 12 1.8 7 2.1 3 2.3

1000 78 0.7 68 1.1 60 1.5 54 1.9 48 2.2 43 2.6 38 3.0 34 3.4 29 3.7 25 4.1

1400 119 1.0 109 1.6 102 2.1 95 2.6 89 3.1 84 3.7 79 4.2 75 4.7 70 5.2 66 5.7

1800 161 1.3 150 2.0 143 2.7 136 3.3 130 4.0 125 4.7 120 5.4 116 6.0 112 6.7 108 7.4

2100 191 1.5 181 2.3 174 3.1 167 3.9 161 4.7 156 5.5 151 6.3 147 7.0 142 7.8

2400 212 2.7 204 3.6 198 4.5 192 5.4 187 6.3 182 7.2 177 8.1

2700 213 8.1

Blower Opening: 52 mm; Standard recommended line size: 40 mmNB; Air Cooled & Water Cooled versions available; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 44

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 80 0.6 69 1.0 61 1.4 55 1.8 49 2.2 44 2.5 39 2.9

1000 125 0.9 114 1.4 106 2.0 100 2.5 94 3.1 88 3.6 84 4.2

1500 199 1.4 189 2.2 181 3.0 174 3.8 169 4.6 163 5.4 158 6.3

1900 259 1.7 249 2.8 241 3.8 234 4.8 228 5.9 223 6.9 218 7.9

2200 304 2.0 294 3.2 286 4.4 279 5.6 273 6.8 268 8.0

2500 349 2.3 339 3.6 331 5.0 324 6.3 318 7.7

2800 394 2.5 384 4.1 376 5.6 369 7.1

Blower Opening: 75 mm; Standard recommended line size: 65 mmNB; Air Cooled Version Only; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 47

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 127 1.1 101 1.8 81 2.5 64 3.2

1000 209 1.6 183 2.6 162 3.6 146 4.6

1500 345 2.4 319 3.9 298 5.4 282 6.8

1900 454 3.0 427 4.9 407 6.8

2200 535 3.5 509 5.7 489 7.9

2500 617 4.0 591 6.5

2800 698 4.5 672 7.2

Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Air Cooled Version Only; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL EXPO 1

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 62 0.8 45 1.2 31 1.6 20 1.9 10 2.3 1 2.7

1500 182 1.7 164 2.5 151 3.4 140 4.2 130 5.0 120 5.8 112 6.6 104 7.4 97 8.3 90 9.1

2000 257 2.3 239 3.4 226 4.5 214 5.6 204 6.6 195 7.7 187 8.8 179 9.9 172 11.0 165 12.1

2400 317 2.7 299 4.1 286 5.4 274 6.7 264 8.0 255 9.3 247 10.6 239 11.9 232 13.2 225 14.5

2800 376 3.2 359 4.7 345 6.3 334 7.8 324 9.3 315 10.8 307 12.4 299 13.9 292 15.4 285 16.9

3200 436 3.7 419 5.4 405 7.2 394 8.9 384 10.6 375 12.4 366 14.1 359 15.9 351 17.6 344 19.4

3600 496 4.1 478 6.1 465 8.0 454 10.0 444 12.0 435 13.9 426 15.9 418 17.9 411 19.8

Blower Opening: 3” BSP; Standard recommended line size: 80 mmNB; Vertical Flow Configuration; Suitable for Air Duty, Pressure Applications only; Air Cooled Version Only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL M5075

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 114 1.3 97 1.8 83 2.4 71 3.0 61 3.6 52 4.1 44 4.7 36 5.3 29 5.8 22 6.4

1000 182 1.8 164 2.6 150 3.5 139 4.3 129 5.1 120 5.9 111 6.7 103 7.5 96 8.4 89 9.2

1500 294 2.7 276 4.0 262 5.2 251 6.4 241 7.6 232 8.9 223 10.1 216 11.3 208 12.5 201 13.8

1900 384 3.5 366 5.0 352 6.6 341 8.1 331 9.7 322 11.2 313 12.8 305 14.3 298 15.9 291 17.4

2200 451 4.0 433 5.8 420 7.6 408 9.4 398 11.2 389 13.0 380 14.8 373 16.6 365 18.4 358 20.2

2500 518 4.5 500 6.6 487 8.6 475 10.7 465 12.7 456 14.8 448 16.8 440 18.8

2800 585 5.1 568 7.4 554 9.7 543 12.0 533 14.2 523 16.5 515 18.8

Blower Opening: 75 mm; Standard recommended line size: 80 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL M5125

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 147 1.4 124 2.2 107 2.9 92 3.6 79 4.4 67 5.1 57 5.9 46 6.6 37 7.3 28 8.1

1000 234 2.1 211 3.1 194 4.2 179 5.2 166 6.3 154 7.3 143 8.4 133 9.4 124 10.5 115 11.5

1500 378 3.1 356 4.7 338 6.2 323 7.8 310 9.4 298 11.0 288 12.6 278 14.1 268 15.7 259 17.3

1900 494 3.9 471 5.9 454 7.9 439 9.9 426 11.9 414 13.9 403 15.9 393 17.9 384 19.9

2200 581 4.5 558 6.8 540 9.1 526 11.5 513 13.8 501 16.1 490 18.4 480 20.7

2500 667 5.1 644 7.8 627 10.4 612 13.0 599 15.7 587 18.3

2800 754 5.7 731 8.7 714 11.6 699 14.6 686 17.5 674 20.5

Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL M5175

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 206 1.7 174 2.8 150 3.8 129 4.8 111 5.9 94 6.9 79 7.9 65 9.0 52 10.0 39 11.0

1000 327 2.5 295 3.9 271 5.4 250 6.9 232 8.4 216 9.8 200 11.3 186 12.8 173 14.3 161 15.7

1500 530 3.7 498 5.9 473 8.1 453 10.3 434 12.6 418 14.8 403 17.0 389 19.2

1900 691 4.7 660 7.5 635 10.3 614 13.1 596 15.9 580 18.7

2200 813 5.4 781 8.7 756 11.9 736 15.2 718 18.4

2500 934 6.2 902 9.9 878 13.6 857 17.2

2800 1056 6.9 1024 11.1 999 15.2 978 19.3

Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

Page 9: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL M5225D

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 286 2.3 246 3.7 214 5.1 188 6.5 165 7.9 144 9.3 125 10.7

1000 451 3.3 410 5.3 379 7.3 353 9.3 330 11.3 309 13.3 289 15.3

1400 670 4.6 630 7.4 599 10.2 572 13.0 549 15.8 528 18.6

1800 890 5.9 849 9.5 818 13.1 792 16.7 769 20.3

2100 1055 6.9 1014 11.1 983 15.3 957 19.5

2400 1219 7.9 1179 12.7 1148 17.5

2700 1312 19.7

Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled version only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas / Duty & Pressure / Vacuum Applications.

Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.MODEL M5225

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 286 2.3 246 3.7 214 5.1 188 6.5 165 7.9 144 9.3 125 10.7 107 12.1 90 13.5 74 14.9

1000 451 3.3 410 5.3 379 7.3 353 9.3 330 11.3 309 13.3 289 15.3 271 17.3 255 19.3

1400 670 4.6 630 7.4 599 10.2 572 13.0 549 15.8 528 18.6

1800 890 5.9 849 9.5 818 13.1 792 16.7 769 20.3

2100 1055 6.9 1014 11.1 983 15.3 957 19.5

2400 1219 7.9 1179 12.7 1148 17.5

2700 1312 19.7

Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas / Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL EXPO 2

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 144 1.3 117 2.1 97 2.8 80 3.6 65 4.3 52 5.1 39 5.8 28 6.6 17 7.3 6 8.1

1500 380 2.8 354 4.4 334 6.0 317 7.7 302 9.3 288 10.9 276 12.5 264 14.1 253 15.7 243 17.4

2000 528 3.8 502 5.9 482 8.1 465 10.2 450 12.4 436 14.5 424 16.7 412 18.8 401 21.0 391 23.1

2400 646 4.5 620 7.1 600 9.7 583 12.3 568 14.8 554 17.4 542 20.0 530 22.6

2800 765 5.3 738 8.3 718 11.3 701 14.3 686 17.3 673 20.3 660 23.4

3200 883 6.0 857 9.5 837 12.9 820 16.3 805 19.8 791 23.2

3600 1001 6.8 975 10.6 955 14.5 938 18.4 923 22.3

Blower Opening: 4” BSP; Standard recommended line size: 100 mmNB; Vertical Flow Configuration; Suitable for Air Duty & Pressure Applications only; Air Cooled version only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL EB6HPM

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 188 1.9 158 2.8 134 3.8 115 4.7 97 5.7 82 6.6 67 7.6

1000 300 2.7 270 4.0 247 5.4 227 6.7 210 8.1 194 9.5 179 10.8

1400 450 3.7 420 5.6 396 7.5 376 9.4 359 11.4 343 13.3 329 15.2

1700 562 4.5 532 6.8 508 9.2 489 11.5 471 13.8 456 16.1 441 18.4

2000 674 5.3 644 8.0 621 10.8 601 13.5 583 16.2 568 18.9 553 21.7

2200 749 5.9 719 8.9 695 11.8 676 14.8 658 17.8 643 20.8 628 23.8

2400 824 6.4 793 9.7 770 12.9 750 16.2 733 19.5 717 22.7 703 26.0

Blower Opening: 85 mm; Standard recommended line size: 100 mmNB; Air Cooled Version Only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 67

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 286 2.1 241 3.6 207 5.0 179 6.4 154 7.9 131 9.3 110 10.7 90 12.1 72 13.6 54 15.0

1000 454 3.0 410 5.1 376 7.1 347 9.2 322 11.2 299 13.3 278 15.3 258 17.3 240 19.4 223 21.4

1400 678 4.3 634 7.1 600 10.0 571 12.8 546 15.7 523 18.6 502 21.4 483 24.3 464 27.1 447 30.0

1700 847 5.2 802 8.6 768 12.1 740 15.6 714 19.1 692 22.5 671 26.0 651 29.5 633 33.0 615 36.4

2000 1015 6.1 971 10.2 937 14.3 908 18.3 883 22.4 860 26.5 839 30.6 819 34.7 801 38.8

2200 1127 6.7 1083 11.2 1049 15.7 1010 20.2 995 24.7 972 29.2 951 33.7 932 38.2

2400 1239 7.3 1195 12.2 1161 17.1 1132 22.0 1107 26.9 1084 31.8 1063 36.7 1044 41.6

Blower Opening: 120 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 610

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 382 2.6 323 4.5 277 6.4 239 8.3 205 10.3 175 12.2 147 14.1 120 16.0 96 17.9 73 19.8

1000 607 3.7 547 6.5 502 9.2 464 11.9 430 14.7 400 17.4 371 20.1 345 22.8 321 25.6 298 28.3

1400 906 5.2 847 9.0 802 12.9 764 16.7 730 20.5 699 24.3 671 28.2 645 32.0 621 35.8 597 39.6

1700 1131 6.3 1072 11.0 1027 15.6 988 20.3 955 24.9 924 29.5 896 34.2 870 38.8

2000 1356 7.5 1297 12.9 1252 18.4 1213 23.8 1180 29.3 1149 34.8 1121 40.2

2200 1506 8.2 1447 14.2 1402 20.2 1363 26.2 1329 32.2 1299 38.2

2400 1656 9.0 1597 15.5 1551 22.1 1513 28.6 1479 35.2

Blower Opening: 150 mm; Standard recommended line size: 125 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL EB615HP

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 601 3.7 515 6.6 450 9.6 395 12.5 346 15.5 302 18.4

1000 946 5.3 861 9.5 796 13.7 740 17.9 692 22.1 648 26.3

1400 1407 7.4 1322 13.3 1257 19.2 1201 25.0 1153 30.9 1109 36.8

1700 1753 9.0 1668 16.1 1602 23.3 1547 30.4 1498 37.5

2000 2099 10.6 2014 19.0 1948 27.4 1893 35.8

2200 2329 11.7 2244 20.9 2179 30.1 2123 39.4

2400 2560 12.7 2474 22.8 2409 32.9

Blower Opening: 125 mm; Standard recommended line size: 150 mmNB; Air Cooled versions only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 615

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 585 3.6 502 6.5 438 9.4 384 12.2 337 15.1 294 17.9 255 20.8 218 23.7

1000 921 5.2 838 9.3 775 13.4 721 17.4 673 21.5 631 25.6 591 29.7 555 33.8

1400 1370 7.3 1287 13.0 1223 18.7 1169 24.4 1122 30.1 1079 35.9 1040 41.6

1700 1707 8.8 1624 15.8 1560 22.7 1506 29.7 1459 36.6

2000 2043 10.4 1960 18.5 1896 26.7 1843 34.9

2200 2267 11.4 2184 20.4 2121 29.4 2067 38.4

2400 2492 12.4 2409 22.3 2345 32.1

Blower Opening: 175 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

Page 10: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 78

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 522 3.0 472 5.4 434 7.7 402 10.1 373 12.4 348 14.7 324 17.1 302 19.4 282 21.8 262 24.1

900 706 3.9 656 6.9 618 9.9 585 12.9 557 15.9 531 19.0 508 22.0 486 25.0 465 28.0 446 31.0

1100 889 4.8 839 8.5 801 12.1 769 15.8 741 19.5 715 23.2 691 26.8 669 30.5 649 34.2 629 37.9

1300 1073 5.6 1023 10.0 985 14.3 953 18.7 924 23.0 898 27.4 875 31.7 853 36.1 832 40.4 813 44.8

1500 1256 6.5 1207 11.5 1168 16.5 1136 21.6 1108 26.6 1082 31.6 1058 36.6 1036 41.6 1016 46.6 996 51.6

1800 1532 7.8 1482 13.8 1444 19.9 1412 25.9 1383 31.9 1357 37.9 1334 43.9 1312 49.9 1291 56.0 1272 62.0

2000 1715 8.7 1666 15.4 1627 22.1 1595 28.7 1567 35.4 1541 42.1 1517 48.8 1495 55.5 1475 62.2

Blower Opening: 130 mm; Standard recommended line size: 125mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 79

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 580 3.3 525 5.9 482 8.5 447 11.1 415 13.7 386 16.3 360 18.9 336 21.5 313 24.1 291 26.7

900 784 4.2 729 7.6 686 10.9 650 14.3 619 17.6 590 21. 0 564 24.3 540 27.6 517 31.0 495 34.3

1100 988 5.2 933 9.3 890 13.4 854 17.4 823 21.5 794 25.6 768 29.7 744 33.8 721 37.9 699 42.0

1300 1192 6.1 1137 11.0 1094 15.8 1058 20.6 1027 25.4 998 30.3 972 35.1 948 39.9 925 44.8 903 49.6

1500 1396 7.1 1341 12.6 1298 18.2 1262 23.8 1231 29.4 1202 34.9 1176 40.5 1152 46.1 1129 51.6 1107 57.2

1800 1702 8.5 1647 15.2 1604 21.9 1568 28.5 1537 35.2 1508 41.9 1482 48.6 1458 55.3 1435 62.0

2000 1906 9.4 1851 16.9 1808 24.3 1772 31.7 1741 39.1 1712 46.6 1686 54.0 1662 61.4

Blower Opening: 140 mm; Standard recommended line size: 125 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 710

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 653 3.6 590 6.6 543 9.5 502 12.4 467 15.3 435 18.3 405 21.2 378 24.1 352 27.0 328 30.0

900 882 4.7 820 8.4 772 12.2 732 15.9 696 19.7 664 23.5 635 27.2 607 31.0 581 34.8 557 38.5

1100 1112 5.7 1049 10.3 1002 14.9 961 19.5 926 24.1 894 28.7 864 33.3 837 37.9 811 42.5 786 47.1

1300 1341 6.7 1279 12.2 1231 17.6 1191 23.0 1155 28.5 1123 33.9 1094 39.3 1066 44.8 1040 50.2 1016 55.6

1500 1571 7.8 1508 14.0 1460 20.3 1420 26.6 1385 32.8 1353 39.1 1323 45.4 1296 51.6 1270 57.9

1800 1915 9.3 1852 16.8 1805 24.4 1764 31.9 1729 39.4 1697 46.9 1667 54.5 1640 62.0

2000 2082 18.7 2034 27.1 1994 35.4 1958 43.8 1926 52.1 1897 60.5

Blower Opening: 140 mm; Standard recommended line size: 125mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 711

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 745 4.0 674 7.4 619 10.7 573 14.0 533 17.4 496 20.7 462 24.1 431 27.4 401 30.7 374 34.1

900 1006 5.2 935 9.5 881 13.8 835 18.1 794 22.4 758 26.6 724 30.9 693 35.2 663 39.5 635 43.8

1100 1268 6.3 1197 11.6 1143 16.8 1097 22.1 1056 27.3 1019 32.6 986 37.8 954 43.1 925 48.3 897 53.5

1300 1530 7.5 1459 13.7 1404 19.9 1358 26.1 1318 32.3 1281 38.5 1248 44.7 1216 50.9 1187 57.1

1500 1792 8.7 1721 15.8 1666 23.0 1620 30.1 1580 37.3 1543 44.4 1509 51.6 1478 58.7

1800 2184 10.4 2113 19.0 2059 27.5 2013 36.1 1972 44.7 1936 53.3 1902 61.9

2000 2446 11.5 2375 21.1 2320 30.6 2274 40.1 2234 49.7 2197 59.2

Blower Opening: 160 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 713

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 848 4.5 767 8.3 705 12.1 653 15.9 607 19.7 565 23.5 526 27.3 491 31.1 457 34.9 426 38.7

900 1146 5.8 1065 10.7 1003 15.6 951 20.4 905 25.3 863 30.2 825 35.1 789 40.0 755 44.9 724 49.8

1100 1444 7.1 1363 13.0 1301 19.0 1249 25.0 1203 31.0 1161 36.9 1123 42.9 1087 48.9 1054 54.9 1022 60.8

1300 1742 8.4 1662 15.4 1599 22.5 1547 29.5 1501 36.6 1459 43.7 1421 50.7 1385 57.8

1500 2041 9.6 1960 17.8 1898 25.9 1845 34.1 1799 42.2 1757 50.4 1719 58.5

1800 2488 11.6 2407 21.3 2345 31.1 2292 40.9 2246 50.7 2205 60.4

2000 2786 12.9 2705 23.7 2643 34.6 2591 45.4 2544 56.3

Blower Opening: 160 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 715

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 986 5.5 892 9.9 820 14.3 759 18.7 705 23.2 657 27.6 612 32.0 571 36.4 532 40.8

900 1333 7.0 1239 12.7 1167 18.4 1106 24.1 1052 29.8 1004 35.5 959 41.1 918 46.8 879 52.5

1100 1680 8.6 1586 15.5 1513 22.5 1453 29.4 1399 36.4 1350 43.3 1306 50.3 1264 57.2

1300 2027 10.2 1932 18.4 1860 26.6 1799 34.8 1746 43.0 1697 51.2 1653 59.4

1500 2373 11.7 2279 21.2 2207 30.7 2146 40.1 2092 49.6 2044 59.1

1800 2893 14.1 2799 25.4 2727 36.8 2666 48.2 2613 59.5

2000 3240 15.6 3146 28.3 3074 40.9 3013 53.5

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL LB17

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1110 6.0 1004 11.0 923 16.0 854 21.0 794 25.9 739 30.9 689 35.9 642 40.9

900 1500 7.7 1394 14.1 1313 20.5 1245 26.9 1184 33.3 1130 39.7 1079 46.1 1033 52.5

1100 1891 9.5 1785 17.3 1703 25.1 1635 32.9 1574 40.7 1520 48.6 1470 56.4

1300 2281 11.2 2175 20.4 2094 29.7 2025 38.9 1965 48.1 1910 57.4

1500 2671 12.9 2565 23.6 2484 34.2 2415 44.9 2355 55.6

1800 3257 15.5 3151 28.3 3069 41.1 3001 53.9

2000 3647 17.2 3541 31.4 3460 45.6 3391 59.9

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 812

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 962 6.9 899 10.9 851 15.0 810 19.0 775 23.1 742 27.1 712 31.2 685 35.3 659 39.3 634 43.4

900 1280 8.8 1217 14.0 1169 19.2 1129 24.5 1093 29.7 1060 34.9 1031 40.1 1003 45.3 977 50.5 952 55.8

1000 1439 9.8 1376 15.6 1328 21.4 1288 27.2 1252 33.0 1219 38.8 1190 44.6 1162 50.4 1136 56.2 1111 61.9

1200 1757 11.8 1695 18.7 1646 25.7 1606 32.6 1570 39.6 1538 46.5 1508 53.5 1480 60.4 1454 67.4 1430 74.3

1400 2076 13.7 2013 21.8 1965 29.9 1924 38.1 1888 46.2 1856 54.3 1826 62.4 1798 70.5 1772 78.6

1600 2394 15.7 2331 24.9 2283 34.2 2242 43.5 2206 52.8 2174 62.0 2144 71.3 2117 80.6

1800 2712 17.6 2649 28.1 2601 38.5 2560 48.9 2525 59.3 2492 69.7 2462 80.2

Blower Opening: 150 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

Page 11: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 814

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1122 7.5 1049 12.3 993 17.0 945 21.7 904 26.5 866 31.2 831 35.9 799 40.7 768 45.4 740 50.1

900 1494 9.7 1420 15.8 1364 21.9 1317 27.9 1275 34.0 1237 40.1 1202 46.2 1170 52.3 1140 58.4 1111 64.4

1000 1679 10.8 1606 17.5 1550 24.3 1502 31.0 1460 37.8 1423 44.6 1388 51.3 1356 58.1 1325 64.8 1297 71.6

1200 2050 12.9 1977 21.0 1921 29.1 1873 37.3 1832 45.4 1794 53.5 1759 61.6 1727 69.7 1696 77.8

1400 2422 15.1 2348 24.5 2292 34.0 2245 43.5 2203 52.9 2165 62.4 2130 71.9 2098 81.3

1600 2793 17.2 2720 28.0 2663 38.9 2616 49.7 2574 60.5 2536 71.3 2502 82.1

1800 3164 19.4 3091 31.5 3034 43.7 2987 55.9 2945 68.0 2908 80.2

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 816

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1283 8.2 1199 13.6 1135 19.0 1080 24.4 1033 29.8 990 35.3 950 40.7 913 46.1 878 51.5 845 56.9

900 1707 10.6 1623 17.5 1559 24.5 1505 31.4 1457 38.4 1414 45.3 1374 52.3 1337 59.2 1302 66.2 1270 73.1

1000 1919 11.7 1835 19.5 1771 27.2 1717 34.9 1669 42.6 1626 50.4 1586 58.1 1549 65.8 1515 73.5 1482 81.3

1200 2343 14.1 2260 23.3 2195 32.6 2141 41.9 2093 51.2 2050 60.4 2010 69.7 1974 79.0

1400 2768 16.4 2684 27.2 2619 38.1 2565 48.9 2518 59.7 2474 70.5 2435 81.3

1600 3192 18.8 3108 31.1 3044 43.5 2990 55.9 2942 68.2 2899 80.6

1800 3616 21.1 3532 35.0 3468 48.9 3414 62.8 3366 76.7

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 818

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1449 8.9 1355 15.0 1282 21.1 1221 27.2 1167 33.4 1118 39.5 1073 45.6 1031 51.7 992 57.8 955 63.9

900 1928 11.5 1834 19.3 1761 27.2 1700 35.0 1646 42.9 1597 50.7 1552 58.6 1511 66.5 1472 74.3 1434 82.2

1000 2168 12.7 2073 21.5 2001 30.2 1940 38.9 1886 47.6 1837 56.4 1792 65.1 1750 73.8 1711 82.6

1200 2647 15.3 2533 25.8 2480 36.2 2419 46.7 2365 57.2 2316 67.7 2271 78.1

1400 3127 17.8 3032 30.0 2960 42.3 2898 54.5 2844 66.7 2796 78.9

1600 3606 20.4 3511 34.3 3439 48.3 3378 62.3 3324 76.2

1800 4085 22.9 3991 38.6 3918 54.3 3857 70.1 3803 85.8

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 820

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1603 9.6 1499 16.3 1418 23.1 1351 29.8 1291 36.6 1237 43.4 1187 50.1 1141 56.9 1098 63.6

900 2134 12.3 2029 21.0 1949 29.7 1881 38.4 1821 47.1 1767 55.8 1718 64.4 1671 73.1 1628 81.8

1000 2399 13.7 2294 23.3 2214 33.0 2146 42.6 2086 52.3 2032 61.9 1983 71.6 1937 81.3

1200 2929 16.4 2824 28.0 2744 39.6 2676 51.2 2617 62.7 2563 74.3

1400 3459 19.1 3355 32.6 3274 46.2 3207 59.7 3147 73.2

1600 3990 21.9 3885 37.3 3805 52.8 3737 68.2

1800 4520 24.6 4415 42.0 4335 59.4 4267 76.7

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 1012

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1644 10.4 1537 17.4 1455 24.3 1385 31.2 1324 38.2 1269 45.1 1218 52.0 1170 59.0 1126 65.9 1084 72.8

900 2188 13.4 2081 22.3 1999 31.2 1929 40.2 1868 49.1 1813 58.0 1762 66.9 1714 75.8 1670 84.7 1628 93.7

1000 2460 14.9 2353 24.8 2771 34.7 2201 44.6 2140 54.5 2084 64.4 2034 74.3 1986 84.2 1942 94.2 1900 104.1

1200 3004 17.9 2897 29.8 2814 41.7 2745 53.5 2684 65.4 2628 77.3 2578 89.2 2530 101.1 2486 113.0 2444 124.9

1400 3548 20.9 3441 34.7 3358 48.6 3289 62.5 3228 76.3 3172 90.2 3121 104.1 3074 117.9 3030 131.8 2988 145.7

1600 4092 23.8 3985 39.7 3902 55.5 3833 71.4 3772 87.2 3716 103.1 3665 118.9 3618 134.8 3574 150.6 3531 166.5

1800 4636 26.8 4529 44.7 4446 62.5 4377 80.3 4315 98.2 4260 116.0 4209 133.8 4162 151.6 4117 169.5 4075 187.3

Blower Opening: 205mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 1014

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 1932 11.6 1806 19.8 1709 27.9 1628 36.1 1556 44.2 1491 52.4 1431 60.5 1375 68.7 1323 76.8 1274 85.0

900 2571 15.0 2445 25.5 2348 35.9 2267 46.4 2195 56.9 2130 67.4 2070 77.8 2014 88.3 1962 98.8 1913 109.3

1000 2891 16.6 2765 28.3 2668 39.9 2586 51.6 2514 63.2 2449 74.8 2389 86.5 2334 98.1 2282 109.8 2232 121.4

1200 3530 20.0 3404 33.9 3307 47.9 3225 61.9 3153 75.8 3088 89.8 3029 103.8 2973 117.7 2921 131.7 2871 145.7

1400 4169 23.3 4043 39.6 3946 55.9 3864 72.2 3792 88.5 3727 104.8 3668 121.1 3612 137.4 3560 153.7 3510 170.0

1600 4808 26.6 4682 45.2 4585 63.9 4503 82.5 4432 101.1 4367 119.7 4307 138.4 4251 157.0 4199 175.6 4149 194.2

1800 5447 30.0 5321 50.9 5224 71.9 5143 92.8 5071 113.8 5006 134.7 4946 155.7 4890 176.6 4838 197.6

Blower Opening: 230 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 1016

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 2210 12.8 2065 22.1 1955 31.5 1861 40.8 1779 50.1 1705 59.4 1636 68.7 1573 78.0 1513 87.4 1456 96.7

900 2941 16.5 2796 28.5 2686 40.44 2592 52.4 2510 64.4 2436 76.4 2367 88.4 2304 100.3 2244 112.3 2187 124.3

1000 3306 18.3 3162 31.6 3051 44.9 2958 58.2 2875 71.6 2801 84.9 2733 98.2 2669 111.5 2609 124.8 2553 138.1

1200 4037 22.0 3893 37.9 3782 53.9 3689 69.9 3606 85.9 3532 101.8 3464 117.8 3400 133.8 3340 149.8 3284 165.7

1400 4768 25.6 4623 44.3 4513 62.9 4419 81.5 4337 100.2 4263 118.8 4194 137.4 4131 156.1 4071 174.7 4014 193.4

1600 5499 29.3 5354 50.6 5244 71.9 5150 93.2 5068 114.5 4994 135.8 4925 157.1 4862 178.4 4802 199.7

1800 6230 33.0 6085 56.9 5974 80.9 5881 104.8 5799 128.8 5725 152.8 5656 176.7

Blower Opening: 230 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 1018

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 2549 14.2 2382 25.0 2255 35.7 2147 46.5 2052 57.2 1966 68.0 1888 78.7 1814 89.5 1745 100.2 1680 111.0

900 3392 18.3 3225 32.1 3098 46.0 2990 59.8 2895 73.6 2809 87.4 2731 101.2 2657 115.1 2588 128.9 2523 142.7

1000 3813 20.4 3647 35.7 3519 51.1 3412 66.4 3317 81.8 3231 97.1 3152 112.5 3079 127.8 3010 143.2 2945 158.5

1200 4657 24.4 4490 42.9 4362 61.3 4255 79.7 4160 98.1 4074 116.6 3995 135.0 3922 153.4 3853 171.8 3788 190.3

1400 5500 28.5 5333 50.0 5205 71.5 5098 93.0 5003 114.5 4917 136.0 4838 157.5 4765 179.0

1600 6343 32.6 6176 57.1 6048 81.7 5941 106.3 5846 130.8 5760 155.4 5681 180.0

1800 7186 36.6 7019 64.3 6892 91.9 6784 119.6 6689 147.2 6603 174.8

Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

Page 12: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL 1020

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 2826 15.4 2642 27.3 2500 39.3 2381 51.2 2276 63.1 2180 75.0 2093 86.9 2012 98.8 1935 110.8 1863 122.7

900 3761 19.8 3577 35.1 3435 50.5 3316 65.8 3210 81.1 3115 96.4 3028 111.8 2946 127.1 2870 142.4 2798 157.7

1000 4229 22.0 4044 39.1 3902 56.1 3783 73.1 3678 90.1 3583 107.2 3495 124.2 3414 141.2 3337 158.2 3265 175.3

1200 5163 26.4 4979 46.9 4837 67.3 4718 87.7 4613 108.2 4518 128.6 4430 149.0 4349 169.4 4272 189.9

1400 6098 30.8 5914 54.7 5772 78.5 5653 102.3 5548 126.2 5452 150.0 5365 173.9 5284 197.7

1600 7033 35.2 6849 62.5 6707 89.7 6588 117.0 6482 144.2 6387 171.4 6300 198.7

1800 7968 39.6 7783 70.3 7642 100.9 7522 131.6 7417 162.2 7322 192.9

Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 1022

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 3042 16.3 2844 29.2 2691 42.0 2563 54.8 2449 67.6 2347 80.5 2253 93.3 2165 106.1 2083 119.0

900 4048 21.0 3850 37.5 3697 54.0 3569 70.5 3456 87.0 3353 103.5 3259 120.0 3171 136.4 3089 152.9

1000 4552 23.3 4353 41.7 4200 60.0 4072 78.3 3959 96.6 3856 115.0 3762 133.3 3675 151.6 3592 169.9

1200 5558 28.0 5359 50.0 5207 72.0 5078 94.0 4965 116.0 4863 137.9 4768 159.9 4681 181.9

1400 6564 32.7 6365 58.3 6213 84.0 6084 109.6 5971 135.3 5869 160.9 5775 186.6

1600 7570 37.3 7372 66.6 7219 96.0 7091 125.3 6977 154.6 6875 183.9

1800 8576 42.0 8378 75.0 8225 108.0 8097 140.9 7984 173.9

Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL 1024

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 3320 17.5 3103 31.5 2937 45.5 2796 59.5 2673 73.5 2561 87.5 2458 101.5 2363 115.5

900 4418 22.5 4201 40.5 4035 58.5 3894 76.5 3771 94.5 3659 112.5 3556 130.5 3461 148.5

1000 4967 25.0 4750 45.0 4584 65.0 4443 85.0 4320 105.0 4208 125.0 4105 145.0 4010 165.0

1200 6065 30.0 5848 54.0 5682 78.0 5541 102.0 5418 126.0 5306 150.0 5203 174.0 5108 198.0

1400 7163 35.0 6946 63.0 6780 91.0 6639 119.0 6516 147.0 6404 175.0

1600 8261 40.0 8044 72.0 7878 104.0 7737 136.0 7614 168.0 7502 200.0

1800 9359 45.0 9142 81.0 8976 117.0 8835 153.0 8712 189.0

Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL ET7000

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 3320 17.5 3103 31.5 2937 45.5 2796 59.5 2673 73.5 2561 87.5 2458 101.5 2363 115.5 2273 129.5 2188 143.5

900 4418 22.5 4201 40.5 4035 58.5 3894 76.5 3771 94.5 3659 112.5 3556 130.5 3461 148.5 3371 166.5 3286 184.5

1000 4967 25.0 4750 45.0 4584 65.0 4443 85.0 4320 105.0 4208 125.0 4105 145.0 4010 165.0 3920 185.0 3835 205.0

1200 6065 30.0 5848 54.0 5682 78.0 5541 102.0 5418 126.0 5306 150.0 5203 174.0 5108 198.0 5018 222.0 4933 246.0

1400 7163 35.0 6946 63.0 6780 91.0 6639 119.0 6516 147.0 6404 175.0 6301 203.0 6206 231.0 6116 259.0

1600 8261 40.0 8044 72.0 7878 104.0 7737 136.0 7614 168.0 7502 200.0 7399 232.0 7304 264.0

1800 9359 45.0 9142 81.0 8976 117.0 8835 153.0 8712 189.0 8600 225.0 8497 261.0

Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL ET9000

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

700 4419 22.1 4131 40.8 3909 59.4 3723 78.0 3558 96.7 3409 115.3 3273 133.9 3145 152.6 3026 171.2 2913 189.9

900 5881 28.5 5593 52.4 5371 76.4 5184 100.3 5020 124.3 4871 148.3 4734 172.2 4607 196.2 4488 220.1 4375 244.1

1000 6612 31.6 6323 58.2 6102 84.9 5915 111.5 5751 138.1 5602 164.7 5465 191.4 5338 218.0 5219 244.6 5105 271.2

1200 8074 37.9 7785 69.9 7564 101.8 7377 133.8 7213 165.7 7064 197.7 6927 229.6 6800 261.6

1400 9536 44.3 9247 81.5 9025 118.8 8839 156.1 8674 193.4 8526 230.6 8389 267.9

1600 10997 50.6 10709 93.2 10487 135.8 10301 178.4 10136 221.0 9987 263.6

1800 12459 56.9 12170 104.8 11949 152.8 11762 200.7 11598 248.6

Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL ERRG350

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

590 11088 58 10758 102 10518 146 10338 190 10176 235 10032 279 9888 323 9768 367 9648 412 9558 457

630 11892 62 11562 109 11322 156 11142 204 10980 251 10836 298 10692 345 10572 393 10452 440 10362 487

670 12696 66 12366 115 12126 166 11946 216 11784 267 11640 316 11496 366 11376 417 11256 468 11166 517

710 13494 70 13164 122 12924 176 12744 229 12582 283 12438 335 12294 389 12174 443 12054 496 11964 548

730 13896 70 13566 125 13326 180 13146 235 12984 290 12840 345 12696 398 12576 453 12456 510 12366 563

Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

MODEL ERRG400

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

590 13926 70 13566 126 13278 181 13026 237 12804 292 12594 349 12426 404 12276 460 12186 488

630 14934 75 14574 134 14286 193 14034 253 13812 312 13602 371 13434 432 13284 491 13194 520

670 15942 79 15582 142 15294 205 15042 270 14820 333 14610 396 14442 459 14292 522 14202 554

710 16950 85 16590 152 16302 219 16050 286 15828 351 15618 418 15450 485 15300 553 15210 586

730 17454 86 17088 154 16806 224 16548 294 16332 361 16122 430 15954 499 15798 569 15714 602

Blower Opening: 400 mm; Standard recommended line size: 400 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

MODEL ERRG445

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC 9000 mmWC 10000 mmWc

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

590 15696 78 15246 142 14934 204 14646 267 14406 329 14196 392 13986 455 13782 518

630 16830 83 16380 152 16068 217 15780 286 15540 351 15330 418 15120 485 14916 553

670 17964 89 17514 161 17202 231 16914 303 16674 373 16464 445 16254 516 16050 587

710 19104 94 18654 170 18342 245 18054 321 17814 396 17604 472 17394 546 17190 622

730 19668 97 19212 174 18900 252 18612 330 18378 406 18162 485 17952 562 17760 640

Blower Opening: 450 mm; Standard recommended line size: 450 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

Page 13: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS

MODEL ERRG450

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 7500 mmWC 8000 mmWC 9000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

590 17556 86 17106 156 16794 226 16506 295 16266 363 16056 433 15846 503 15744 538

630 18816 91 18366 166 18054 240 17766 314 17526 389 17316 463 17106 536 17004 574

670 20076 98 19626 177 19314 255 19026 334 18786 413 18576 492 18366 571 18264 610

710 21342 103 20892 186 20580 271 20292 354 20052 439 19842 522 19632 605 19530 648

730 21972 106 21516 192 21204 278 20916 363 20682 449 20466 536 20256 622 20160 665

Blower Opening: 450 mm; Standard recommended line size: 450 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

MODEL ERRG500

AIR COOLED WATER COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 6500 mmWC 7000 mmWC 8000 mmWC 9000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

590 21684 105 21144 190 20742 276 20394 362 20064 448 19782 534 19644 578

630 23244 111 22704 203 22302 295 21954 386 21624 479 21342 570 21204 616

670 24804 118 24264 216 23862 314 23514 410 23184 508 22902 606 22764 654

710 26364 125 25824 228 25422 333 25074 436 24744 539 24462 642 24324 708

730 27144 129 26604 235 26202 339 25854 447 25524 553 25242 660 25104 709

Blower Opening: 500 mm; Standard recommended line size: 500 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWC Suitable for Air / Gas Duty & Pressure / Vacuum Applications.

EZR SERIES LARGE SIZE HIGH PRESSURE

PD BLOWERS

Everest Blowers areavailable aspackage units,ready to installor as bare blowerunits for replacement

Everest is proud to introduce its new range of EZR series PD Blowers. EZR series blowers arelarge size, high pressure, rotary blowers which have been developed on our rich manufacturingexperience to cater to the demand for large capacity & high pressure rotary blowers. It has aspecial rotor profile which results in a high efficiency & energy saving machine.

FEATURES: Rotor with truss head involute profile, advanced and reasonable, with high efficiency. Main parts are machined by machining centres and NC facilities, resulting in complete interchangeability, high

accuracy & reliable product. Forced lubrication for gears and bearings.The oil pump is driven by the blower shaft, so no need for extra power. Also,

we can use separate electrical power to drive the oil pump. All models work in direct drive mode. Available seals: Labyrinth seal, piston ring seal &air extracting seal.

SCOPE OF SUPPLY (TWIN LOBE & TRILOBE BLOWERS):

A) Bare Blower:1. Blower; 2. Suction & Discharge ICP/Companion Flanges; 3. Blower Pulley

B) Blower With Standard Accessories (Pressure Duty) Including Water Cooled Blowers:

1.Blower; 2. Common Motor & Blower Base Frame with Motor Rails &Belt Tightening Arrangement; 3. Belt Guard / Coupling Guard; 4. SuctionAir Filter; 5. Suction Silencer; 6. Pressure Gauge; 7. Safety Relief Valve(Spring Loaded Type); 8. Pulleys & Vee Belts / Coupling; 9. FoundationBolts; 10. Interconnecting Pipe with Companion Flange; 11. O&M Manual

C) Blower with Standard Accessories (Vacuum Duty):1. Blower; 2. Common Motor & Blower Base Frame with Motor Rails & Belt Tightening

Arrangement ; 3. Belt Guard / Coupling Guard; 4. Discharge Silencer; 5.Vacuum Gauge ;

6. Vacuum Relief Valve (Spring Loaded Type); 7. Pulleys & Vee Belts / Coupling; 8.

Foundation Bolts; 9. Interconnecting Pipe with Companion Flange; 10. O&M Manual

D) Blower with Standard Accessories (Gas Duty):1.Blower; 2. Common Motor & Blower Base Frame with Motor Rails &Belt Tightening Arrangement; 3. Belt Guard / Coupling Guard; 4. Pr./Vac.Gauge; 5. Pulleys & Vee Belts / Coupling; 6. Foundation Bolts; 7.Interconnecting Pipe with Companion Flanges; 8. O&M Manual

Water Cooled Package Blowersfor High Pressure Applications

BlowerFor Mechanical Vapor Re-compression

Delivery medium: Air, semi water, gas. Newly designed oil tank structure with effective heat emission. Cooling water is required only if operating pressures

exceed 5000 mmWC, thereby reducing operating expenses. Split structure design for casing & end plates, resulting in convenience during inspection.Main parts are formed by

precision resin sand casting. Straight Gear instead of traditional skew gear to avoid excess shaft force which would affect bearing life.

Performance Range:Pressure Rise from 1,000 mmWC to 10,000 mmWCCapacity from 317.9 m3/min to 1292 m3/min

Application Areas include Food, Mining, Cement, Pneumatic Conveying, Petrochemical, Smelting,Environmental, Electric Power.

EZR SERIES PERFORMANCE TABLE

MODEL P Q (m3/min)

EZR7 - 500A 1,000 - 10,000 mmWC 317.9~378.1

EZR7 - 580B 1,000 - 9,000 mmWC 379.2 ~ 530.4

EZR7 - 600A 1,000 - 9,000 mmWC 411.5 ~584.3

EZR7 - 700A 1,000 - 8,000 mmWC 465.7~661.2

EZR7 - 750A 1,000 - 6,000 mmWC 555.3 ~740.7

EZR7 - 800A 1,000 - 5,000 mmWC 637.7 ~841.6

EZR7 - 700B 1,000 - 8,000 mmWC 663.1 ~897.0

EZR7 - 800B 1,000 - 6,000 mmWC 804.7 ~1,058.2

EZR7 - 900B 1,000 - 5,000 mmWC 997 ~1,292

Please contact Everest for further details.

Page 14: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

SINGLE STAGE HIGH SPEED CENTRIFUGAL BLOWERS (TURBO BLOWERS)

Everest is proud to introduce its new range of Single Stage High Speed Centrifugal Blowers (Turbo Blowers).

FEATURESl Large capacity and continuous flow because of big size sectional area and high rotary speed.l Compact structure, smaller size than Piston Compressor and Roots Blower of same capacity.l Long time stable running and less maintenance.l No pollution on the compressed Gas.l Wide range of Impeller material: Forged Aluminum, Forged Steel or Stainless Steel.l Gear Box Design with Helical Type Nitrogen-hardening gears with more than 20 years life.l Designed on tri-variate movement theory resulting in high efficiency of 82%.l Wide Performance Range:With axial inlet guide vanes, flow capacity range can be adjusted

from 45% to110% of the designed value.l High Pressure Ratio, Max 3.0.l GD2 is low, easier to start.l Easily to control the Noise. High grade balanced and light style rotor will generate high

frequency noise which can be easily eliminated.l Covers less floor space.l Reliable operation.

Standard Unit consists of High Speed Single Stage Centrifugal Blower, Gear Box,Control Cabinet, Inlet GuideVanes & Thin Oil Station.

Performance Range:3 3

Flow Capacity: 60 m /min to 1,000 m /min2 2

Outlet Pressure: 1.5 kgf/cm ~ 2.8 kgf/cm

Application Areas include Waste Water Treatment,FGD Oxidation Air Blower & MVR.

Please contact Everest for further details.

MULTISTAGE CENTRIFUGAL BLOWERS

Everest Blowers areavailable as package units, ready to install or as bare blower unitsfor replacement

Multistage Centrifugal Blowers (Casting Type) are based on design & principle of welded multistage low speed

centrifugal blowers.These new generation high efficiency products are the latest product offering from Everest Group.

FEATURESl Shell of inlet & outlet and return channel of the blower are fully adapt to impeller resulting in

streamlined design & hence reduced losses.l Impeller is designed by three-dimensional meridian plane and compound curve technology,

resulting in high efficiency.l Impeller intake seal-inducer improves inlet fluidity of the impeller.l Airfoil return flow blade reduces losses resulting in higher static pressures.l Blower performance is optimized with fluid analysis technology. Polytropic efficiency is upto 78%.

l Some models use three dimensional impeller, resulting in higher efficiency & good performance.

l Rotors are dynamically balanced, resulting in low vibration, high reliability & low overall noise.l Advanced & reasonable blower structure with no easy-worn parts and convenient installation,

operation & maintenance.

Standard Unit consists of Blower, coupling, protective cover and anchor bolts. Special accessories (Filter, Silencer, etc.) are prepared according to specific process requirements.

Performance Range:Flow Capacity: 20 m3/min to 800 m3/minOutlet Pressure: 0.2 kgf/cm2 ~ 1 kgf/cm2

Application Areas include Water Treatment, Waste Water

Treatment, Biogas Recovery, Vacuum Cleaning, Air Knife

Drying, Flotation & Mineral Beneficiation, Galvanization

Process & Electroplating, Fluid & Piscina Oxygenation,

Process Gas Conveying, Paper Making & Printing, & Air Firing

(Desulphurization, Carbon Black, Blast Furnace Process etc.).

Please contact Everest for further details.

Page 15: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Tri-Lobe Rotary Air

Blowers have been

designed keeping the

specific demands of

the industry of

continuous dutyoperation, sturdydesign, reduced

noise, reducedpulsations and

vibrations, longerbearing life and

minimalmaintenance in

mind

ETL 300 EVEREST | AIR COOLED

PACKAGE BLOWER SYSTEMS

TRI-LOBE ROTARY AIR BLOWERS

VEREST, leading manufacturer of Roots Blowers in India, introduces the all EnewTri-Lobe Roots Blowers.Tri-lobe technology means blowers have lobe tips exposed

to 120 degrees around the rotor instead of 180 degrees as in a bi-lobe blower.Thisprovides a stiffer rotor set, meaning less deflection at any load.These

blowers have been designed keeping the specific demands of the industry of

continuous duty operation, sturdy design, reduced noise, reduced pulsations and

vibrations, longer bearing life and minimal maintenance in mind. Everest Blowers

are produced on the latest state-of-art CNC machines from Haas (USA), Mazak

(Japan ) and HMT (India), thereby ensuring a quality product.These blowers are

designed for continuous duty service. Complete package units are shipped with all

essential accessories and electric motor, ready to install, on plug and play concept.

Everest Tri-Lobe blowers are supplied with built-in safety & monitoring equipment

such as safety relief valve and Pressure/Vacuum gauge.

WORKING PRINCIPLE

POSITION-1 POSITION-2 POSITION-3 POSITION-4

Everest Tri-Lobe Rotary Compressors/Blowers are positive displacement units, whose

pumping capacity is determined by size, operating speed and pressure conditions. It

employs two Tri-Lobe impellers mounted on parallel shafts, rotating in opposite direction

within a casing closed at the ends by side plates. As the impellers rotate, air is drawn into

one side of the casing and forced out of the opposite side against the existing pressures.

The differential pressure developed, therefore, depends upon the resistance of the

connected system. The Blowers, being positive displacement type, do not develop

pressure within the casing but the discharge pressure depends upon the system

resistance/back pressure. Effective sealing of the compressor inlet area from the

discharge area is accomplished by use of very small operational clearance, eliminating

the need of any internal lubrication of the lobes. A pair of accurately machined alloy steel,

hardened and ground timing gears maintain clearances between the impellers, during

rotation.The air, thus delivered, is 100% OIL FREE. The pumping capacity of a lobe

compressor, operating at constant speed remains relatively independent of inlet and

discharge pressure variations. These Blowers are constant volume machines, which

deliver a fixed discharge against the system back pressure. It is, therefore, essential to

ensure that minimum pipeline restrictions, at the inlet and discharge, are imposed.

Adequate size piping and large radius bends ensure minimum line losses resulting in

higher efficiency and low power

TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORSTRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS

ACOUSTIC HOODS | ENCLOSURES

These Blowers areconstant volumemachines, whichdeliver a fixeddischarge againstthe system backpressure

consumption. Sudden change in pipeline cross section should also be avoided.

To change capacity, it is necessary either to change speed (energy saving) or

vent some of the air into atmosphere (not energy saving).The air must not be re-

circulated from the discharge to suction as it may result in overheating. No

attempt should ever be made to control the capacity of compressor by means of

throttle valves in the intake or discharge piping. This increases the power load

on the motor and may seriously damage the compressor.There is an increase in

the discharge air temperature due to heat of compression. As a thumb rule the

discharge air temperature increases @ 100C for every 0.1 Kg/cm2 of P above the

inlet temperature.

FEATURES

Anti-friction bearings

Tri Lobe Rotor design, suitable for both Pressure Duty andVacuum Duty

100% oil free air delivery

Fail safe labyrinth sealing

Extended shaft design for cool running

Rigid one piece CI casing & end plates

Standard Orientation: Right Angle Flow

Large inlet & outlet connections for minimal loss

Alloy steel toughened shafts ground to close tolerances

Factory engineered, Factory guaranteed, superior product

Alloy steel hardened and ground timing gears, oil splash lubricated

Improved volumetric efficiency and reduced operating temperatures

Dynamically balanced rotor shaft assembly (Grade 6.3 ISO 1940-1986)

Performance testing as per standard test procedure STP-01 based on BS 1571-2:1975 and ISO 1217:2009

Tri-Lobe construction having low pulsations and low noise

All blowers are manufactured on state of the art, imported CNC machines, machined to close

tolerances with high degree of accuracy on profile machining, ensuring high volumetric efficiency

All major components are interchangeable making Everest the first and only manufacturer to attain the same

Non-contact type labyrinth seals, with vent, offers lifelong sealing

Right angle flow orientation with suction top, resulting in smaller foot print

Page 16: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 17: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS

MODEL ETL40

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

1500 31 0.3 25 0.5 21 0.6 17 0.8 14 1.0 11 1.1

2000 46 0.4 40 0.6 36 0.9 32 1.1 29 1.3 26 1.5

2400 58 0.5 52 0.8 48 1.0 44 1.3 41 1.5 38 1.8

2700 67 0.6 61 0.9 56 1.1 53 1.4 50 1.7 47 2.0

3000 75 0.6 70 1.0 65 1.3 62 1.6 58 1.9 56 2.3

3300 84 0.7 79 1.0 74 1.4 71 1.8 67 2.1 64 2.5

3600 93 0.8 88 1.1 83 1.5 80 1.9 76 2.3 73 2.7

Blower Opening: 40 mm; Standard recommended line size: 40 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red Values for BHP indicate suitable for Intermittent Duty Applications only.

MODEL ETL50

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 67 0.9 53 1.2 41 1.6 32 2.0 24 2.3 16 2.7 10 3.1 3 3.5

1200 118 1.3 104 1.8 92 2.4 83 2.9 75 3.5 67 4.1 61 4.6 54 5.2

1500 156 1.6 142 2.3 131 3.0 121 3.7 113 4.4 106 5.1 99 5.8 92 6.5

1800 195 1.9 180 2.8 169 3.6 160 4.4 151 5.3 144 6.1 137 6.9 131 7.8

2200 246 2.3 231 3.4 220 4.4 211 5.4 202 6.4 195 7.4 188 8.5 182 9.5

2500 284 2.7 269 3.8 258 5.0 249 6.1 241 7.3 233 8.5 226 9.6 220 10.8

2800 322 3.0 308 4.3 296 5.6 287 6.9 279 8.2 271 9.5 265 10.8 258 12.1

Blower Opening: 50 mm; Standard recommended line size: 50 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Blue cells for FAD indicate next higher standard line size recommended.

MODEL ETL65

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 116 1.0 100 1.6 87 2.2 77 2.7 67 3.3 59 3.9 51 4.4 44 5.0

1200 193 1.6 177 2.4 165 3.3 154 4.1 145 5.0 136 5.8 129 6.6 121 7.5

1500 251 2.0 235 3.0 223 4.1 212 5.1 203 6.2 195 7.3 187 8.3 180 9.4

1800 310 2.4 293 3.6 281 4.9 270 6.2 261 7.4 253 8.7 245 10.0 238 11.2

2200 387 2.9 371 4.4 358 6.0 348 7.5 339 9.1 330 10.6 322 12.2 315 13.7

2500 445 3.3 429 5.0 416 6.8 406 8.6 397 10.3 388 12.1 381 13.9 373 15.6

2800 487 5.6 475 7.6 464 9.6 455 11.6 446 13.5 439 15.5

Blower Opening: 65 mm; Standard recommended line size: 65 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.

MODEL ETL80

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 209 1.8 179 2.9 155 3.9 136 4.9 118 6.0 102 7.0 88 8.0 74 9.0

1200 351 2.7 320 4.3 297 5.8 277 7.4 260 8.9 244 10.5 229 12.0 216 13.6

1500 457 3.4 426 5.4 403 7.3 383 9.2 366 11.2 350 13.1 336 15.0 322 17.0

1800 563 4.1 533 6.4 509 8.8 489 11.1 472 13.4 456 15.7 442 18.0 428 20.4

2100 669 4.8 639 7.5 615 10.2 596 12.9 578 15.6 562 18.3 548 21.0 534 23.8

2400 745 8.6 721 11.7 702 14.8 684 17.9 669 21.0 654 24.1 641 27.1

2700 760 27.1 747 30.5

Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.

PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS

MODEL ETL100

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 306 2.2 270 3.7 242 5.1 218 6.5 197 8.0 179 9.4 161 10.9 145 12.3

1200 503 3.4 467 5.5 439 7.7 415 9.8 394 12.0 376 14.1 358 16.3 342 18.4

1500 651 4.2 615 6.9 587 9.6 563 12.3 542 15.0 524 17.7 506 20.4 490 23.0

1800 799 5.0 763 8.3 735 11.5 711 14.7 690 18.0 671 21.2 654 24.4 638 27.7

2200 996 6.1 960 10.1 932 14.0 908 18.0 887 21.9 869 25.9 851 29.8

2500 1144 7.0 1108 11.5 1080 16.0 1056 20.5 1035 24.9 1016 29.4

2800 1292 7.8 1256 12.9 1228 17.9 1204 22.9 1183 27.9 1164 33.0

Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.

MODEL ETL125

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 640 3.8 589 6.6 550 9.3 517 12.1 488 14.9 462 17.7 438 20.5 416 23.2

1000 831 4.7 780 8.2 741 11.7 708 15.1 679 18.6 653 22.1 629 25.6 606 29.0

1200 1022 5.7 971 9.8 932 14.0 899 18.2 870 22.3 844 26.5 820 30.7 797 34.8

1400 1212 6.6 1161 11.5 1122 16.3 1090 21.2 1061 26.1 1034 30.9 1010 35.8 988 40.7

1600 1403 7.6 1352 13.1 1313 18.7 1280 24.2 1251 29.8 1225 35.3 1201 40.9 1179 46.5

1800 1594 8.5 1543 14.8 1504 21.0 1471 27.3 1442 33.5 1416 39.8 1392 46.0 1369 52.3

2000 1784 9.4 1734 16.4 1695 23.3 1662 30.3 1633 37.2 1606 44.2 1582 51.1 1560 58.1

Blower Opening: 125 mm; Standard recommended line size: 125 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Blue cells for FAD indicate next higher standard line size recommended.

MODEL ETL150

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 863 4.6 813 8.2 775 11.7 743 15.3 715 18.9 689 22.5 665 26.1 643 29.6

1000 1109 5.7 1059 10.2 1021 14.7 989 19.2 960 23.6 935 28.1 911 32.6 889 37.1

1200 1355 6.9 1305 12.2 1267 17.6 1235 23.0 1206 28.4 1181 33.7 1157 39.1 1135 44.5

1400 1600 8.0 1551 14.3 1512 20.6 1480 26.8 1452 33.1 1426 39.4 1403 45.6 1381 51.9

1600 1846 9.2 1796 16.3 1758 23.5 1726 30.6 1698 37.8 1672 45.0 1649 52.1 1627 59.3

1800 2092 10.3 2042 18.4 2004 26.4 1972 34.5 1944 42.5 1918 50.6 1894 58.7 1872 66.7

2000 2338 11.5 2288 20.4 2250 29.4 2218 38.3 2189 47.3 2164 56.2 2140 65.2 2118 74.1

Blower Opening: 150 mm; Standard recommended line size: 150 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.

MODEL ETL200

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 1403 8.7 1309 14.7 1236 20.6 1175 26.6 1121 32.5 1072 38.5 1027 44.4 986 50.3

900 1607 9.8 1513 16.5 1440 23.2 1379 29.9 1325 36.6 1276 43.3 1231 50.0 1189 56.6

1000 1811 10.9 1717 18.4 1644 25.8 1583 33.2 1529 40.6 1480 48.1 1435 55.5 1393 62.9

1200 2219 13.1 2124 22.0 2052 30.9 1991 39.9 1937 48.8 1888 57.7 1843 66.6 1801 75.5

1400 2627 15.3 2532 25.7 2460 36.1 2399 46.5 2345 56.9 2296 67.3 2251 77.7 2209 88.1

1600 3035 17.5 2940 29.4 2868 41.3 2807 53.1 2753 65.0 2704 76.9 2659 88.8 2617 100.7

1800 3443 19.7 3348 33.0 3276 46.4 3214 59.8 3161 73.2 3112 86.5 3067 99.9 3025 113.3

Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.

Page 18: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

EVEREST TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORSTRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

PRESSURE & VACUUM SYSTEMS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORSACOUSTIC HOODS | ENCLOSURES

ETL100 Everest | Air Cooled

PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS

MODEL ETL250

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 2199 11.9 2076 21.0 1981 30.1 1902 39.2 1831 48.3 1768 57.4 1709 66.5 1655 75.5

900 2511 13.4 2388 23.6 2293 33.8 2214 44.1 2143 54.3 2080 64.5 2022 74.8 1967 85.0

1000 2823 14.9 2700 26.2 2605 37.6 2526 49.0 2455 60.3 2392 71.7 2334 83.1 2279 94.4

1200 3447 17.8 3324 31.5 3230 45.1 3150 58.8 3080 72.4 3016 86.0 2958 99.7 2903 113.3

1400 4071 20.8 3948 36.7 3854 52.6 3774 68.6 3704 84.5 3640 100.4 3582 116.3 3528 132.2

1600 4696 23.8 4572 42.0 4478 60.2 4398 78.3 4328 96.5 4264 114.7 4206 132.9 4152 151.1

1800 5320 26.8 5196 47.2 5102 67.7 5022 88.1 4952 108.6 4889 129.1 4830 149.5 4776 170.0

Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only;

MODEL ETL300

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

800 4911 24 4276 44 4583 63 4464 83 4358 102 4263 122 4175 141 4093 161

900 5580 27 5395 49 5253 71 5133 93 5028 115 4933 137 4845 159 4763 181

1000 6250 30 6065 55 5923 79 5803 104 5698 128 5602 152 5515 177 5433 201

1200 7589 36 7404 66 7262 95 7142 124 7037 154 6942 183 6854 212 6772 241

1400 8929 43 8744 77 8602 111 8482 145 8376 179 8281 213 8193 247

1600 10268 49 10083 88 9941 127 9821 166 9716 205 9620 244

1800 11607 55 11422 99 11280 143 11161 186 11055 230 10960 274

Blower Opening: 300 mm; Standard recommended line size: 300 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.

MODEL E3HF350

AIR COOLEDSPEED 1000 mmWC 2000 mmWC 3000 mmWC 4000 mmWC 5000 mmWC 6000 mmWC 7000 mmWC 8000 mmWC

RPM Q P Q P Q P Q P Q P Q P Q P Q Pm3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

650 8958 47 8658 83 8418 120 8208 157 8022 193 7860 230

730 10170 54 9870 93 9630 136 9420 176 9234 217 9072 258

800 11220 58 10920 105 10680 148 10470 192 10284 237 10122 282

880 12438 63 12138 114 11898 162 11688 212 11502 262 11340 310

980 13944 70 13644 126 13404 181 13194 235 13008 290 12846 345

Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.

STANDARD ACCESSORIESCommon Motor & Blower Base Frame with Motor Rails and Belt tightening arrangement, BeltGuard/Coupling Guard, Suction Air Filter, Suction Silencer, Pressure Gauge, Pressure Relief Valve(Spring Loaded), Pulleys & Belts/Coupling, Foundation Bolts, Interconnecting Line with Flanges, Non-Return Valve, Operation & Maintenance Manual. Discharge Silencer for Model ETL 100 and above.Electric Motor forms a part of Standard Accessories for Package Blower Systems only.

SALIENT FEATURES All Blowers are manufactured on state-of-the-art, imported CNC machines to close tolerances

and high degree of accuracy on profile machining, ensuring high volumetric efficiency All major components are interchangeable Blowers are energy efficient Trilobe construction having low pulsations & low noise Blowers have all bearings and gears oil splash lubricated. Additionally they have non contact

Labyrinth Seals with vent.Therefore these blowers are suitable for high speed and high pressure

Right-angle flow orientation with suction top, resulting in smaller foot print

ETL300 Everest | Air Cooled

Page 19: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Tri-Lobetechnology meansblowers have lobe

tips exposed to120 degrees

around the rotor,instead of 180

degrees as in a bi-lobe blower

ETL 025 EVEREST | AIR COOLED

PACKAGE BLOWER SYSTEMS

TRI-LOBE VERTICAL ROTARY AIR BLOWERS

VEREST, leading manufacturer of Roots Blowers in India, introduces the all EnewVertical Tri-Lobe Roots Blowers. These blowers have been designed keeping the

specific demands of the industry of compact & sturdy machine, reduced noise,minimal space requirements, least vibrations, longer bearing life & minimal

maintenance, in mind. Everest blowers are produced on latest state-of-artCNC machines from USA & Japan ensuring quality product.

Complete package units are shipped with all essential accessories &electric motor, ready to install on plug & play concept. These blowersare designed for continuous duty service & require minimalmaintenance. EverestVertical Tri-Lobe Blowers come with built-in safetyand monitoring equipment such as safety relief valve & pressure gauge.

Tri-Lobe technology means blowers have lobe tips exposed to 120 degrees

around the rotor, instead of 180 degrees as in a bi-lobe blower.This provides a

stiffer rotor set, meaning less deflection at any load. These blowers provide

100% Oil Free Air & are extensively used in Sewage Treatment Plants, Effluent

Treatment Plants, Aquaculture, Chemical Plants and Electroplating Plants.

TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS Everest Tri-LobeTRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORSTWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS Vertical Rotary AirACOUSTIC HOODS | ENCLOSURES

Blowers areproduced on lateststate-of-art CNCmachines fromUSA & Japanensuring quality

FEATURES product

Quieter Operation:The Tri-Lobe rotor enables smooth air output, with less pulsations.This results in a significant reduction of emitted sound.

LONGER Longer Life: The smooth power cycles means less “impacting load” and results in longer bearing andL I F E unit life.

A convenient sight glass makes it easy to check oil levels. Drain valve is mounted in the front of the unit,

hence easily accessible.Direct coupled drive resulting in increased drive efficiency, reduced noise and longer service life.

Built-in monitoring and safety equipment such as pressure gauge and safety relief valve.

Anti-vibration pads absorb vibrations before they reach the floor.

Easily mountable suction air filter with non woven polyester media for surface and depth filtration.

Mean pore size 25 microns.

SPECIFICATIONS Noise level < 80dB(A) (subject to load conditions)

Unit Weight: 48 Kg (with 1.5 HP/2 Pole Electric Motor)

Variable Frequency Drive can be supplied for speed/capacity regulation

Standard Orientation: Horizontal Flow

Blower Opening : 1” BSP

Recommended Line Size : 25 mmNB

PERFORMANCE TABLE | TRI-LOBE VERTICAL ROTARY AIR BLOWERS PRESSURE DUTY APPLICATIONMODEL SPEED 1000 mmWg 2000 mmWg 3000 mmWg 4000 mmWg 5000 mmWg1.5 HP Motor rpm m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP m3/hr BHP

ETL 25 EB Package 2850 26 0.4 23 0.5 20 0.7 18 0.8 16 0.9

Capacities are at inlet condition | Tolerance: Capacity ±10% and Power +5%Conversions: 1 M3/Hr~0.588 CFM~16.67 LPM | 1000 mmWG~1.42 PSI~0.1 Kg/cm2

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 20: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

Reduction ofmechanical noise

is beyond thescope of silencers.Everest acoustic

enclosures areone of the mosteffective meansfor containment

of excessivenoise

EVEREST PACKAGE BLOWER

PACKAGE BLOWER SYSTEMS

ACOUSTIC HOODS | ENCLOSURESVEREST, leading manufacturer of Roots Blowers introduces acoustic

Eenclosures for blowers. Everest acoustic enclosures are one of the mosteffective means for containment of excessive noise and for the insulation of the

workers from the noise. Even where silencers are used, they can only treat the airborne noise. The treatment of the mechanical noise from the blower, motor, etc. is

beyond the scope of silencers.Thus, in order to achieve low noise levels, that are

often statutory requirements, Noise Enclosures / Acoustic Hoods are required.

Everest sound reduction enclosures have been designed for effective noise reduction of

blowers placed inside. Everest's economical design provides noise reduction of 12-25

dB(A) bringing down the total noise emitted to safe acceptable limits.

TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS

TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS

TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS

ACOUSTIC HOODS | ENCLOSURES

Everest's economical

design providesnoise reductionof 12 - 25 dB(A)

FEATURES

Noise Control Noise level reduction to the tune of 25-30% is achieved

Mobility The enclosures can be easily shifted or transported

Ease of Maintenance Adequate space is available inside the canopy for easy maintenance

Elimination of Civil Work Enclosures are suitable for open installation and hence require

no separate building or shed.

SPECIFICATIONS Design The sound reduction enclosures are specially designed to reduce noise pollution to suit the local

environment.These are engineered to take care of air intake & outlet, resulting in a pleasing & attractive design.

Construction The robust body work of sound reduction enclosures is due to its construction from

preformed heavy gauge sheet steel section and its reinforcement with fabricated superstructure.

Rubber gaskets are provided to all doors and external joints to resist weathering.The bolted

superstructure provides easy removal of panels for maintenance or servicing of blowers.

Air Circulation Sufficient cooling air inlet acoustic louvers and exhaust fans are provided

in the enclosure for efficient air circulation avoiding derating of the machine.

Installation The sound reduction enclosures are preassembled on a support frame and can

be easily & quickly assembled at site.

Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service

Page 21: Blowers Manufacturer and Supplier in USA - Leading the way … · 2018. 5. 17. · largest Roots Blower manufacturer in the country and a leader in its segment. Broad Product Line

Leading the way for INNOVATIVE SOLUTIONS

EVERESTPRESSURE & VACUUM SYSTEMS

THE EVEREST ADVANTAGERetain your advantage with factory genuine replacement parts &accessories. All parts meet original manufacturing specificationsand tolerances for guaranteed fit and function. Pre-packagedoverall kits with detailed service manuals are available on request.

EverestSpares andAccessories

BEARINGS SILENCERS & FILTERS

GEARS VEE BELTS SEALS

FEATURES SPARES ACCESSORIES• Readily available Bearings, Oil Seals, Gears, Rotors, Safety Relief Valves, Filters, Suction

• Fast delivery Spacer Bushes, Blower lubricant, Silencers, Discharge Silencers,

• Guaranteed fit and function Gaskets, Piston Rings. Pulleys, Vee Belts, Hubs, Drivecouplings, Pressure Gauge, Vacuum

• Service kits for routine product Gauge, Non ReturnValves.maintenance

ROTOR SET RELIEF VALVE PRESSURE GAUGE

GREASE GEAR OIL NON RETURN VALVE

Due to constant improvements, technical specifications are subject to change without notice.For further clarifications, contact our technical team who shall be glad to assist you to overcome application related problems.