bermad ir-970-m0-50-rvz

Upload: rita-caselli

Post on 03-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 BERMAD IR-970-M0-50-RVZ

    1/2

    Flow Control

    BERMAD Irrigation900 Series

    Flow Control

    HydrometerMagnetic Drive

    with Hydraulic Control

    IR-970-M0-50-RVZ

    The BERMAD Model IR-970-M0-50-RVZ integrates a

    vertical turbine Woltman-type water meter with a diaphragmactuated hydraulic control valve. As the system's Flow

    Meter and Main Valve, it controls irrigation together with the

    irrigation controller. The BERMAD Hydrometer limits the flow

    to a constant preset maximum. It either opens or shuts in

    response to pressure commands.

    Features and Benefits

    Integrated "All-in-One" Control Valve

    Saves space, cost and maintenance

    Line Pressure Driven, Hydraulically Controlled On/Off

    Limits fill-up rate and consumer over-demand

    Magnetic Drive with Vacuum-Sealed Register

    Water-free gear train mechanism

    Reed-switch and Opto pulse-generating modes

    Various pulse combinations

    Internal Inlet & Outlet Flow Straighteners

    Saves on straightening distances

    Maintains accuracy

    Integrated Flow Metering Calibration Device

    Paddle-Type Hydro-Mechanic Flow Pilot

    No added head loss Wide setting range

    User-Friendly Design

    Easy Flow Setting

    Simple in-line inspection and service

    [1] BERMAD Model IR-970-M0-55-RVZ opens in response

    to an electric signal limiting fill-up rate and consumer over

    demand.

    [2] BERMAD Backwash Valve Model IR-3x2-350-A-I

    [3] BERMAD Backwash Flow Control Valve Model IR-470-beKU

    Typical Applications

    Computerized Irrigation Systems

    Flow Monitoring and Leakage Control

    Multiple Independent Consumer Systems

    Line Fill-Up Control Irrigation Machines

    Filter Stations

    [1]

    [2][2][2]

    [3]

  • 7/28/2019 BERMAD IR-970-M0-50-RVZ

    2/2

    Flow ControlFor full technical details, refer to Engineering Section.

    Technical Specifications

    BERMAD Irrigation900 Series

    i n f o @ b e r m a d . c o m w w w . b e r m a d . c o mThe info rmati on herein is subjec t to change wi thout not ice. BERMAD shal l no t be held liab le f orany errors. All rights reserved. Copyright by BERMAD.

    Dimensions and WeightsSize DN

    Inch803

    1004

    1506

    2008

    25010

    L mm 300 350 500 600 600inch 11.8 13.8 19.7 23.6 23.6

    Hmm 382 447 602 617 617inch 15 17.6 23.7 24.3 24.3

    Cmm 290 340 450 465 465inch 11.4 13.4 17.7 18.3 18.3

    Rmm 123 137 216 228 228inch 4.8 5.4 8.5 9 9

    A; Bmm 305 325 390 390 415inch 12 12.8 15.4 15.4 16.3

    WeightKg 23 31 71 93 141Ib. 57.7 68.3 156.5 205 310.9

    ,

    IR-970-M0-50-RVZ

    The Flow Pilot [1] commands the Hydrometer to throttle

    closed should demand rise above pilot setting, and to

    modulate open when demand drops. The Shuttle Valve [2]

    directs the pilot command into the Hydrometer Control

    Chamber [3]. Upon pressure rise command, the shuttle valve

    automatically switches, allowing pressurization of the control

    chamber, which causes the Hydrometer to shut.

    The Manual Selector [4] enables local manual closing.

    PC9AEM0-70-50R 05

    Operation

    12.510.0

    7.5

    5.0

    2.5

    1.5

    0.15

    1.0

    0.75

    0.5

    0.25

    P

    psi

    3

    DN80

    4

    DN100

    6

    DN150

    1.0

    0.80.60.5

    0.4

    0.3

    0.2

    0.15

    0.01

    0.1

    0.08

    0.060.05

    0.04

    0.03

    0.02

    0.015

    6 8 10 15 20 30 4 0 60 8 0 100 150 200 300 400 600Flowm3/h

    Flowgpm 50 75 25

    050

    075

    0

    1000

    150025

    2000

    250010

    0150

    200

    300

    350400

    P

    bar

    8 & 10

    DN200 & 250

    Flow Chart

    Technical DataPatterns and Sizes:Globe: 3-10; DN80-250

    Angle 90: 3-8; DN80-200Angle 120: 4; DN100End Connections:Flanged: 3-10; DN80-250Pressure Ratings: 16 bar; 232 psiMinimum Operating Pressure:0.5 bar; 7 psiFor lower pressure requirements,consult factoryFlow Setting Range:1.0-5.0 m/sec; 3.3-16.5f/secSetting ranges vary according to specific pilot

    spring. Please consult factory.

    Materials:Body and Cover:Polyester Coated Cast or Ductile IronInternals:St. St. & Glass Fiber Reinforced NylonImpeller: PolypropyleneElastomers: Reinforced NR & NBRPivots and Bearings: Tungsten CarbideControl Accessories: Brass

    Tubing and Fittings:

    Reinforced Plastic and Brass

    [2]

    [1]

    [4]

    [3]

    Globe G

    Angle A

    120 (4; DN100 only) H

    ISO-16 16

    ISO-10 10

    ISO-14 (ISO-10/4 Holes) 14

    ANSI-125 A1

    JIS-10 J1

    BST-D BD

    Metal Control Accessories R

    Paddle Flow Control Pilot V

    Manual Selector Z

    R.S. 100 Lit R02 R.S. 10 Gal RG4

    R.S. 1 m3 R03 R.S. 100 Gal RG5

    R.S. 10 m3 R04 R.S. 1000 Gal RG6

    R.S. 100 Lit +1 m3 R23 R.S. 10+100 Gal G45

    R.S. 1 m3+10 m3 R34 R.S. 100+1000 Gal G56

    O.E. 1 Lit P01 O.E. 0.1 Gal PG2

    O.E. 10 Lit P10 O.E . 1 Gal PG3

    O.E.+R.S. 1+100 Lit PQ1 O.E.+R.S. 0.1+10 Gal P4G

    O.E.+R.S. 10 Lit+1 m3 P13 O.E.+R.S. 1+100 Gal P5G

    R.S. No Pulse RNP R.S. No Pulse Gal RNG

    How to OrderPlease specify the requested valve in the following sequence: (for more options, refer to Ordering Guide.)

    Sector Size PrimaryFeature

    ControlCategories

    AdditionalFeature

    Pattern ConstructionMaterials

    EndConnections

    Coating Voltage &Position

    Tubing &Fittings

    DialCapacity

    PulseRate

    AdditonalAttributes

    IRIR 970970 5050 GG 1616I PGPG -- PBPB WATWAT RVZRVZ0M0 R23R23-10"3-10"

    Other attributes available on request

    Plastic Tubing & Brass Fittings PB

    Copper Tubing & Brass Fittings CB

    R.S. = Reed-Switch O.E. = Opto-Electric

    Other sizesavailable onrequest.

    R.S. = Reed-Switch

    O.E. = Opto-ElectricTwo parllel pulses are transmitted. other pulse rates are avaiable on request.

    Pulse OptionOne pulse per

    SizeLiter ; Gallon m3 ; Gallon

    1; 0.1 10; 1 100; 10 1; 100 10; 1000

    3-4"; DN80-100

    6-10"; DN150-250

    Accuracy &Flow Data (ISO 4064-1, Class B)

    Size Accuracy DNinch

    803

    1004

    1506

    200 & 2508 & 10

    Q min(Minimum flow)

    5%m3 1.2 1.8 4 6.3

    gpm 5.3 7.9 17.6 27.7Qn, ISO 4064-1(Nominal flow)

    2%m3 40 60 150 250

    gpm 176 264 660 1100

    Qper=Q3(Permanent flow)

    2%m3 100 160 250 400

    gpm 440 704 1100 1760

    2-Way Circuit "Added Head Loss",