bergh 42.585 kw planset - final

28
42.585 kW Grid Tied PV System Shelli Bergh 21511 US Hwy 63 N Sturgeon MO 65284 660-591-6424; [email protected] Missouri Sun Solar, LLC 1926 West Woodland Springfield, MO 65807 PVGI-1 Designer D. Hults Reviewer B. Arthur General Information Grid Tied PV System Date 2016-03-11 Scale NTS System Specifications, Main Components: Roof Mount Item Manufacturer Model Quantity Size: In Array Area: Sqft Weight: Lbs Array Weight: Lbs Watts: kW Panel Module Q-Cell Q-Pro.G4 255 167 65.7 x 39.4 x 1.38 3179.68 41.89 6995.63 255 Inverter 1 Fronius Primo 8.2-1 4 16.9 x 24.7 x 8.1 47.29 8200 Inverter 2 Fronius Primo 5.0-1 1 16.9 x 24.7 x 8.1 47.29 5000 Attachment S-5! Protea Bracket with PV Kit 184 0.789 144.39 Generator Generac RG022: 22kW, 60Hz 1 76.8 x 46.1 x 35 905 22000 Transfer Switch Generac RTSN200G3: 200A 1 24.1 x 20.2 x 7.1 48 Roof Specifications Array Specifications Site Specifications Average Loads Weight 2" x 4" Truss or 6" Framing 24" O.C. 'HVLJQ /RZ 7HPS ) Occupancy: Utility Down: 245 lbs Total Weight: 7140.02 lbs Corrugated Metal Roof 'HVLJQ +LJK 7HPS ) Building Size: 2 Story Uplift: -137 lbs Weight at Attachment: 38.8 lbs 5RRI 3LWFK $]LPXWK Design Wind Speed: 115 MPH Lateral: 38 lbs Distributed Weight: 2.25 psf Roof Age: 20 years Exposure Category: B Expected Life Span: 10+ years Ground Snow Load: 20 PSF FP Table of Contents PVGI-1 General Information PVAL-2 Array Layout PVMN-3 Materials & Notes PVED-4 Electrical Diagram Attachments 1) Panel Data 2) Panel Warranty 3) Inverter Data 4) Inverter Warranty 5) Monitor Data 6) AC Disconnect Data 7) Transfer Switch Data 8) Generator Data 9) Attachment Data Scope of Work 1) Scope includes the installation of a Photovoltaic Array in a Roof Mounted Racking System including related Hardware and Electrical Equipment 2) All Electricity generated is for consumption on the site 3) Permit shall include labor of running of Electrical Conduit(s), installation of new Electrical Equipment, and Electrical Connection to the Existing Site Transformer 4) The Project does not include the installation of Batteries and Battery Management Equipment Boone County Electric 1667002 Jurisdiction: Boone County MO Permit, Inspection Shelli Bergh 21511 US Hwy 63 N, Sturgeon, MO 65284 660-591-6424; [email protected] DC: 42.585 kW AC: 37.8 kW Missouri Sun Solar Contact Information: Primary Contact: Ryan Roller: 417-713-1786: [email protected] Design: David Hults: 314-856-2171: [email protected] Engineer: Billy Arthur, MO PE: 314-6503263: [email protected]

Upload: david-hults

Post on 22-Jan-2018

300 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Bergh 42.585 KW Planset - Final

42.585 kW

G

rid T

ied P

V S

ystem

Sh

elli B

erg

h

21511 U

S H

wy 63 N

Sturgeon M

O 65284

660-591-6424; shellibergh@

em

bargm

ail.com

Missouri Sun Solar, LLC

1926 West Woodland

Springfield, MO 65807

PVGI-1

Designer

D. Hults

Reviewer

B. Arthur

General Information

Grid Tied PV System

Date

2016-03-11

Scale

NTS

System Specifications, Main Components: Roof Mount

ItemManufacturer

Model Quantity Size: In Array Area: Sqft Weight: Lbs Array Weight: LbsWatts: kW

Panel ModuleQ-Cell

Q-Pro.G4 255167

65.7 x 39.4 x 1.383179.68 41.89 6995.63 255

Inverter 1 Fronius Primo 8.2-1 4 16.9 x 24.7 x 8.1 47.29 8200

Inverter 2Fronius

Primo 5.0-11 16.9 x 24.7 x 8.1 47.29 5000

AttachmentS-5!

Protea Bracket with PV Kit184 0.789 144.39

GeneratorGenerac

RG022: 22kW, 60Hz1 76.8 x 46.1 x 35 905 22000

Transfer

Switch

GeneracRTSN200G3: 200A

1 24.1 x 20.2 x 7.1 48

Roof Specifications Array SpecificationsSite Specifications Average Loads Weight

2" x 4" Truss or 6" Framing 24" O.C. Design Low Temp: -20° FOccupancy: Utility

Down: 245 lbs

Total Weight: 7140.02 lbs

Corrugated Metal Roof Design High Temp: 110° FBuilding Size: 2 Story Uplift: -137 lbs Weight at Attachment: 38.8 lbs

Roof Pitch: 6/12 (27°)

Azimuth: 126°

Design Wind Speed: 115 MPH

Lateral: 38 lbs

Distributed Weight: 2.25 psf

Roof Age: 20 years Exposure Category: B

Expected Life Span: 10+ years Ground Snow Load: 20 PSF

FP

Table of Contents

PVGI-1 General Information

PVAL-2

Array Layout

PVMN-3 Materials & Notes

PVED-4

Electrical Diagram

Attachments

1)

Panel Data

2) Panel Warranty

3)

Inverter Data

4) Inverter Warranty

5)

Monitor Data

6)

AC Disconnect Data

7)

Transfer Switch Data

8)

Generator Data

9)

Attachment Data

Scope of Work

1)

Scope includes the

installation of a Photovoltaic

Array in a Roof Mounted

Racking System including

related Hardware and

Electrical Equipment

2)

All Electricity generated is for

consumption on the site

3)

Permit shall include labor of

running of Electrical

Conduit(s), installation of

new Electrical Equipment,

and Electrical Connection to

the Existing Site Transformer

4)

The Project does not include

the installation of Batteries

and Battery Management

Equipment

Boone County Electric

1667002

Jurisdiction: Boone County MO Permit, Inspection

Shelli Bergh

21511 US Hwy 63 N, Sturgeon, MO 65284

660-591-6424; [email protected]

DC: 42.585 kW

AC: 37.8 kW

Missouri Sun Solar Contact Information:

Primary Contact: Ryan Roller: 417-713-1786: [email protected]

Design: David Hults: 314-856-2171: [email protected]

Engineer: Billy Arthur, MO PE: 314-6503263: [email protected]

Owner
Typewritten Text
Owner
Typewritten Text
Page 2: Bergh 42.585 KW Planset - Final

Missouri Sun Solar, LLC

260 Old State Rd.

Ellisville, MO 63021

PVAL-2

Designer

D. Hults

Reviewer

B. Arthur

Array Layout

42.585 kW

G

rid T

ied P

V S

ystem

Sh

elli B

erg

h

21511 U

S H

wy 63 N

Sturgeon M

O 65284

66

0-5

91

-6

42

4; sh

ellib

erg

h@

em

ba

rg

ma

il.co

m

Date

2016-03-11

Scale

NTS

N

Entrance

String Design

Inverter 1: Fronius Primo 8.2-1

2 Strings of 13 Panels

1 String of 11 Panels

Inverter 2: Fronius Primo 5.0-1

1 String of 10 Panels

1 String of 9 Panels

MD

G

HOUSE

LAKE

BARN

House Northern Exterior

Existing Utility Meter in Transformer

Transfer Switch: Generac RTSN200G3

Standby Generator: Generac 22kW: RG022

PV AC Disconnect: Square-D 200A: D324NRB

LOCUS Monitor

Interior Northern Wall of House

Main Electrical Panels

2x 200A/240V

27'-2"

30'-8"

129'-8"

117'-7"

Trench

4/0 Al Direct BuryCable

in 2 Bundles of 4 Cables

8 Cables Total

Minimum 18" Below Grade

Approximately 450'

Roof of Barn

167 Q-Cell 255W Solar Panels

Module Q-Pro.G4 255

Corrugated Metal Roofing

Protea Bracket and PVKit Attachments

Pitch: 6/12 (27°)

Azimuth: 126°

2012 IFC Setbacks

MD G

PV AC Disconnect Existing Utility MeterGeneratorTransfer Switch

For the Layout

On the Right

10 Panels

9 Panels

13 Panels

13 Panels

11 Panels

Solar Panel

13

13

11

13

11

13

13

11

13

Azimuth: Southeast 126°

36" from Ridge and Rake

of Roof per 2012 IFC

Interior Southwest Wall of Barn

Main Service Panel for Barn

200A/240V

L

L

INV1

INV1

INV1

INV1

INV2

Exterior Northwestern Area of Building

In-Ground Tap Box for Electrical Service and Solar

Subpanel

Inverters: Fronius 8.2-1 (x4)

Fronius 5.0-1 (x1)

INV2LOCUS MonitorSolar Inverter

T

T

Existing Transformer

Page 3: Bergh 42.585 KW Planset - Final
Page 4: Bergh 42.585 KW Planset - Final

DC

PVED-3

Missouri Sun Solar, LLC

260 Old State Rd.

Ellisville, MO 63021

Designer

D. Hults

Reviewer

B. Arthur

Electrical Diagram

42.585 kW

G

rid T

ied P

V S

ystem

Sh

elli B

erg

h

21511 U

S H

wy 63 N

Sturgeon M

O 65284

660-591-6424; shellibergh@

em

bargm

ail.com

Date

2016-03-11

Scale

NTS

All Equipment Clearly Labeled with Descriptive Signage

Roof

of

Barn

Fused AC Disconnect

Square D D324NRB

200A / 240V

167 Q-Cell Solar Panels

255W

Module Q.Pro-G4 255

M

To Utility

Existing

Utility Meter

in Transformer

600A/240V

200A

Type R Fuses

A

Exterior Northern

Side of House

Adjacent to the House Entrance

Bergh Solar Project 42.59 kW: Electrical Diagram

C

C

All Conductors

at this Point

Strings

E

D

Wire Schedule

Tag

Wire

Type

Ground Conduit

Length

AUSE-2 PV NA NA 650'

B #10 THHN Cu #10 THHN 3/4" EMT 100'

C 3/0 AWG THHN Cu #10 THHN 2" PVC 20'

D

4/0 Direct Bury Cable: 4 Wires for Each:

Solar and Barn Service

CU NA NA 410'

E 4/0 AWG THHN CU #3 THHN 2" PVC 40'

Sub Panel

200A/240V

Inverter 1: Fronius Primo 8.2-1 (x4)

Inverter 2: Fronius Primo 5.0-1 (x1)

45A

LOCUS

Monitor

L-Gate 120

D

To House

Loads

200A Service

to Barn

200A

Solar

45A

45A

45A

20A

L

13

11

13

13

13

11

13

13

11

13

13

11

10

9

C

C

E

G

Generac Generator

3-Phase 22kW

Model RG022

Generac Transfer Switch

3-Phase 200A

Model RTSN200G3

To Barn

Loads

In-Ground

Tap-Box

400A

Northwest Wall of Barn

All Conductors

at this Point

B

Boone Electric

Solar Meter

250A*

200A

*B

oo

ne

C

ou

nty R

eq

uire

s S

yste

m O

CP

D a

t M

AX

A

MP

x 1

25

%

The Generac Generator and Transfer-Switch will be manipulated by the

Manufacturer to change from 3-Phase to Single Phase; they will maintain

the 3-Poles to comply with Boone Electrical Cooperative Requirements

Page 5: Bergh 42.585 KW Planset - Final

Q.PRO BFR-G4 255-265

1 APT test conditions: Cells at -1000 V against grounded, with conductive me-tal foil covered module surface, 25 °C, 168 h

2 See data sheet on rear for further information.

POLYCRYSTALLINE SOLAR MODULE

The new Q.PRO BFR-G4 is the result of the continued evolution of our Q.PRO family. Thanks to improved power yield, excellent reliability, and high-level operational safety, the new Q.PRO BFR-G4 generates electricity at a low cost (LCOE) and is suitable for a wide range of applications.

THE IDEAL SOLUTION FOR:

Rooftop arrays on commercial / industrial buildings

Ground-mountedsolar power plants

Rooftop arrays onresidential buildings

LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 16.2 %.

INNOVATIVE ALL-WEATHER TECHNOLOGYOptimal yields, whatever the weather with excellent low-light and temperature behavior.

ENDURING HIGH PERFORMANCELong-term yield security with Anti-PID Technology1,Hot-Spot-Protect and Traceable Quality Tra.Q™.

LIGHT-WEIGHT QUALITY FRAMEHigh-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa).

MAXIMUM COST REDUCTIONSUp to 10 % lower logistics costs due to higher module capacity per box.

SAFE ELECTRONICSProtection against short circuits and thermally induced power losses due to breathable junction box and welded cables.

A RELIABLE INVESTMENTInclusive 12-year product warranty and 25-year linear performance guarantee2.

ANTI PID TECHNOLOGY(APT)

HOT-SPOT PROTECT(HSP)

TRACEABLE QUALITY(TRA.Q™)

YIELD SECURITY

151 modules tested

Best polycrystallinesolar module 2013

Q.PRO-G2 235

MOD 278 8 p oton n o/ abo a ory

Quality Tested

ID. 40032587

high re iabi itylow degradationfrequentproduct survei lance

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Owner
Text Box
1) Panel Data
Owner
Rectangle
Page 6: Bergh 42.585 KW Planset - Final

MECHANICAL SPECIFICATIONFormat 65.7 in × 39.4 in x 1.26 in (including frame)

(1670 mm × 1000 mm × 32 mm)

Weight 41.45 lb (18.8 kg)

Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology

Back Cover Composite film

Frame Black anodized aluminum

Cell 6 × 10 polycrystalline solar cells

Junction box 4.33 in × 4.53 in × 0.9 in (110 mm × 115 mm × 23 mm),Protection class IP67, with bypass diodes

Cable 4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm)

Connector Tyco Solarlok PV4, IP68DETAIL A 0 630 (16 mm)

0 335 (8 5 mm)0 965 (24 5 mm)

Junction bo×

Product label

38 58 (980 mm)

65 7 (1670 mm)

4 × Fastening points (DETAIL A)

Cable withconnectors

Frame

5 90 (150 mm)

39 4 (1000 mm)

37 44 (951 mm)

1 26 (32 mm)

8 × Drainage holes

6 × Grounding points ø 0 177 (4 5 mm)

39 37 (1000 mm)

Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE

IRRADIANCE [W/m²]

RELA

TIVE

EFF

ICIE

NCY

[%

]

100 200 300 400 500 600 700 800 900 1000

105

100

95

90

85

80

I rad anc [W/m ]

Reat

ie

effic

ecy

[%

]

PROPERTIES FOR SYSTEM DESIGNMaximum System Voltage VSYS [V] 1000 (IEC) / 1000 (UL) Safety Class II

Maximum Series Fuse Rating [A DC] 20 Fire Rating C / TYPE 1

Max Load (UL)2 [lbs/ft2] 75 (3600 Pa) Permitted module temperatureon continuous duty

− 40 °F up to +185 °F(− 40 °C up to +85 °C)

Load Rating (UL)2 [lbs/ft2] 55.6 (2666 Pa) 2 see installation manual

QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATIONNumber of Modules per Pallet 32

Number of Pallets per 53' Container 32

Number of Pallets per 40' Container 26

Pallet Dimensions ( L × W × H ) 68.7 in × 45.0 in × 46.0 in(1745 × 1145 × 1170 mm)

Pallet Weight 1323 lb (651 kg)

NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.

RELA

TIVE

EFF

ICIE

NCY

COM

PARE

D TO

NOM

INAL

POW

ER [

%] 100

95

90

85

80

75

155 25200 10

YEARS

97

Q CELLS

Industry standard for tiered warranties*

Industry standard for linear warrant es*

*Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014)

CertifiedUL 1703(254141)

TEMPERATURE COEFFICIENTS

Temperature Coefficient of ISC α [% / K] + 0.04 Temperature Coefficient of VOC β [% / K] − 0.30

Temperature Coefficient of PMPP γ [% / K] − 0.41 Normal Operating Cell Temperature NOCT [°F] 113 ± 5.4 (45 ± 3 °C)

UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class A

Spe

cific

atio

ns s

ubje

ct t

o te

chni

cal c

hang

es ©

Han

wha

Q C

ELLS

Gm

bH Q

.PR

O B

FR-G

4_2

01

5-0

4_R

ev0

3_N

A

At least 97 % of nominal power during first year. Thereafter max. 0.6 % degra-dation per year.At least 92 % of nominal power after 10 years.At least 83 % of nominal power after 25 years.

All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.

The typical change in module efficiency at an irradiance of 200 W/m² in relation to 1000 W/m² (both at 25 °C and AM 1.5 G spectrum) is -2 % (relative).

Hanwha Q CELLS USA Corp.300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL [email protected] | WEB www.q-cells.us

ELECTRICAL CHARACTERISTICSPOWER CLASS 255 260 265

MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W /- 0 W)

Min

imum

Power at MPP2 PMPP [W] 255 260 265

Short Circuit Current* ISC [A] 9.07 9.15 9.23

Open Circuit Voltage* VOC [V] 37.54 37.77 38.01

Current at MPP* IMPP [A] 8.45 8.53 8.62

Voltage at MPP* VMPP [V] 30.18 30.46 30.75

Efficiency2 η [%] ≥ 15.3 ≥ 15.6 ≥ 15.9

MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3

Min

imum

Power at MPP2 PMPP [W] 188.3 192.0 195.7

Short Circuit Current* ISC [A] 7.31 7.38 7.44

Open Circuit Voltage* VOC [V] 34.95 35.16 35.38

Current at MPP* IMPP [A] 6.61 6.68 6.75

Voltage at MPP* VMPP [V] 28.48 28.75 29.0111000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ

Owner
Rectangle
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 7: Bergh 42.585 KW Planset - Final

LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA Q . C E L L S GMBH]

Dear Customer, You have made an excellent choice in purchasing quality modules from [Hanwha Q.CELLS GmbH] (“Q CELLS”). The photovoltaic modules you have purchased have been manufactured with great care and have undergone a final functional test. We also provide the following limited warranty (“Warranty”):

SCOPE This Warranty applies exclusively to Q CELLS photovoltaic modules of the following types (the “Modules”): • Q.PEAK G2 • Q.PEAK G3 • Q.PEAK BLK G2 • Q.PEAK BLK G3 • Q.PRO G2 • Q.PRO G3 • Q.PRO L All Modules must be sold and installed within the United States and bear our manufacturer‘s label to be elig ble for this Warranty. Warrantor is Hanwha Q.CELLS GmbH, OT Thalheim, Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany. The applicable Warranty period begins on the date of the initial purchase of the Modules by the original end customer as set forth in the applicable invoice (the “Purchase Date”). 12-YEAR PRODUCT WARRANTY Q CELLS warrants to you that Modules which are installed in accordance with the applicable installation and operation manual and other product documentation provided to customers by Q CELLS for the Modules (collectively, “Product Instructions”) will not show any defects in materials or workmanship for a period of twelve years after the applicable Purchase Date. In the event that a Module has any such defect covered by this warranty (case of warranty), Q CELLS, at its choice, will either repair the defect or supply a replacement Module. If Q CELLS is unable to repair the defect or supply a replacement Module, Q CELLS will have the right to refund you the prorated value of the purchase price paid by you to Q CELLS or Q CELLS’ authorized reseller for the affected Modules (“Purchase Price”), provided that you first return to Q CELLS the affected Module. The foregoing constitutes your sole and exclusive remedy for a breach of the warranty set forth in this paragraph (the “Product Warranty”). 25-YEAR LINEAR PERFORMANCE WARRANTY In addition, Q CELLS provides you the following performance warranty (“Performance Warranty”) for Modules which are installed in accordance with the applicable Product Instructions: In the first year after the Purchase Date the Modules will produce a minimum power output of at least 97 % of that specified in the Module data sheet. From a period beginning on the first anniversary of the Purchase Date and ending on the twenty-fifth anniversary of the Purchase Date, the Modules will have a yearly maximum decrease of power output (degradation) of not more than 0.6 % of the power output specified in the Module data sheet within the framework of the power tolerance, i.e. the Module will have a minimum power output of at least 83 % of the power output specified in the Module data sheet at the end of the twenty-five year period. All power output measurements will be performed under the STC Standard Test Conditions used by Q CELLS on the Purchase Date. The STC Standard Test Conditions are customary standardized basic conditions for the measurement of the power of solar modules. The currently valid STC Standard Test Conditions

are defined in the IEC standards EN 61215 and 60904-3. In the event of a breach of this Performance Warranty, Q CELLS will, at its choice, repair the defect, replace the affected Module, supply additional modules sufficient to make up for the power output reduction, refund you the full Purchase Price of the affected Module provided that you first return to Q CELLS the affected Module, or refund you a percentage of the Purchase Price of the affected Module equal to the percentage reduction in minimum power output compared to the minimum power output warranted under this Performance Warranty. The foregoing constitutes your sole and exclusive remedy for a breach of this Performance Warranty. EXCLUSIONS FROM THE PRODUCT AND PERFORMANCE WARRANTY Irrespective of contributory root causes, this Warranty does not cover the following cases: • Handling, storage, installation, configuration, testing, or use not

in accordance with the Product Instructions (e.g., static, installation of mutually incompatible modules, inadequate system design, and incompatible inverter);

• Repair, servicing or maintenance work not in accordance with the Product Instructions or failure to perform maintenance as required by the Product Instructions.

• Usage in an environment outside the parameters specified in the Product Instructions, including without limitation high snow load outside such parameters;

• Usage for purposes or in circumstances not conforming to the product specifications (as set out in the module data sheet applicable to the modules in any given case) and not complying with the installation and operating instructions;

• Damage caused by environmental sources, such as but not limited to pollution of any kind as well as fire, explosion, smoke or charring;

• Damage caused by acts of nature or God, including without limitation lightning, hail, frost, snow, or storms;

• Damage caused by abuse, negligence, neglect, or accident, including without limitation acts of violence and vandalism

• Damages to the photovoltaic system in which the Modules are installed, or damages caused by factors such as voltage fluctuations, power peaks, excess voltage, power failure etc.;

• Scratches, marks, mechanical wear, rust, mold, degradation, dis-coloration and other changes which occur after the delivery of the Modules but which do not result in any adverse effect on the mechanical stability of the Module or a reduction of performance which exceeds the levels set out in the Performance Warranty; and

• Issues not reproduc ble by Q CELLS. The following cases are also excluded from the Warranty: • The Q CELLS Modules are modified or altered or used in

processes involving other products without obtaining prior written consent from Q CELLS.

• The serial number or product label has been removed, changed, deleted or made unrecognizable or if it is no longer clearly distinguishable for other reasons beyond Q CELLS’ control and therefore it is not possible to conclusively identify the Modules.

Use on mobile carriers such as motor vehicles or ships. As part of the warranty there is no claim to compensation for the

Owner
Text Box
2) Panel Warranty Data
Owner
Rectangle
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 8: Bergh 42.585 KW Planset - Final

LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM [HANWHA Q . C E L L S GMBH]

reimbursement of costs for dismantling, installation or replacement, loss of yield or other indirect damages. CLAIMS UNDER WARRANTY/NOTIFICATION OF DEFECTS You must check the Modules for visible defects upon delivery. If you discover any defects, you must report these immediately to Q CELLS. You must report any Warranty claim to Q CELLS during the applicable Warranty period and no later than thirty (30) days after discovering the breach of Warranty. Please contact us first in writing or electronically. Contact information, the required data and the procedure of the complaint process are described in document Q CELLS’ RMA process (Return Merchandise Authorization). You must follow the RMA process to be eligible for Warranty service. If you have any questions please contact your seller or Q CELLS at the following e-mail address: [email protected]. We ask for our customers’ understanding that Q CELLS cannot accept any unauthorized return shipments of Modules and will not take delivery of such items. PERFORMANCE OF THE WARRANTY SERVICES In all cases, Q CELLS shall have the choice in accordance with this Warranty as to how Warranty claims are settled. Q CELLS may use the services of a third party service partner for this purpose. • Q CELLS shall pay the costs of a technical inspection of the

affected Module in case of a Warranty claim. If there is no breach of Warranty as reasonably determined by Q CELLS, you will pay these costs

• Q CELLS shall only accept liability under the performance warranty if the performance parameters measured by Q CELLS in the STCs (Standard Test Conditions) are not achieved.

• The returned Modules shall remain your property unless Q CELLS chooses to replace such Modules, in which case ownership of the replaced Modules passes to Q CELLS.

• Any repaired or replaced Modules shall be covered by the Warranty for the remaining portion of the original Warranty period as applicable.

• If Q CELLS supplies replacement or additional modules under this Warranty and the original Module type is no longer available, Q CELLS will have the right to provide replacement or additional modules of a similar or equivalent type from the product range available at the time of the claim as long as they are suitable for the intended purpose.

• In the event of glass breakage, Q CELLS reserves the right to perform a static calculation to verify the substructure was designed in accordance with the Product Instructions.

• Q CELLS will have no liability in connection with this Warranty for any costs or expenses of dismantling or installing Modules or

replacement modules. DISCLAIMER EXCEPT AS EXPRESSLY SET FORTH IN THE PRODUCT WARRANTY AND THE PERFORMANCE WARRANTY, Q CELLS HEREBY DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS, IMPLIED, OR STATUTORY, REGARDING THE MODULES, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT OF THIRD-PARTY RIGHTS, AND SYSTEM INTEGRATION. LIMITATION OF LIABILITY Q CELLS WILL NOT BE LIABLE FOR ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL, INDIRECT, OR INCIDENTAL DAMAGES, INCLUDING ANY DAMAGES FOR LOST PROFITS OR LOSS OF YIELD, ARISING FROM OR RELATING TO THIS WARRANTY OR THE MODULES, EVEN IF Q CELLS KNEW OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES. Q CELLS’ TOTAL CUMULATIVE LIABILITY ARISING FROM OR RELATED TO THIS WARRANTY AND THE MODULES, WHETHER IN CONTRACT OR TORT OR OTHERWISE, WILL NOT EXCEED THE PRODUCT PRICE FOR THE MODULE(S) AT ISSUE. THE FOREGOING LIMITATIONS OF LIABILITY ARE INDEPENDENT OF EXCLUSIVE REMEDIES FOR BREACH OF THIS WARRANTY. Q CELLS DISCLAIMS ALL LIABILITY OF ANY KIND OF Q CELLS’ SUPPLIERS UNDER THIS AGREEMENT. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. THE DISCLAIMERS, EXCLUSIONS, AND LIMITATIONS OF LIABILITY UNDER THIS WARRANTY WILL NOT APPLY TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ASSIGNMENT OF WARRANTY FOR PV MODULES This Warranty for PV Modules in its entirety, extends only to the original purchaser, and is transferrable in its entirety to any other person to whom title to the PV Modules has been transferred provided that a) a prior written notice of such transfer has been received by Q CELLS, and b) the PV Modules remain installed in their original installation location. GOVERNING LAW These Warranty terms and conditions shall be exclusively governed by the laws of the State of California, without giving effect to any conflict of laws principles that would require the application of the laws of another State laws principles that would require the application of the laws of another State.

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 9: Bergh 42.585 KW Planset - Final

/ Perfect Welding / Solar Energy / Perfect Charging

/ With power categories ranging from 3.8 kW to 15.0 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnapINverter hinge mounting system which allows for lightweight, secure and convenient installation and service. The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range, Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius’ online and mobile platform Fronius Solar.web. The Fronius Primo is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution.

TECHNICAL DATA FRONIUS PRIMO

/ The future of residential solar is here - Introducing the new Fronius Primo.

/ SuperFlex Design

/ Wi-Fi®* interface

/ Smart Grid Ready

/ Arc Fault Circuit Interruption

/ SnapINverter mounting system

/ PC board replacement process

FRONIUS PRIMO

GENERAL DATA FRONIUS PRIMO 3.8 - 8.2 FRONIUS PRIMO 10.0-15.0

Dimensions (width x height x depth) 16.9 x 24.7 x 8.1 in. 20.1 x 28.5 x 8.9 in.Weight 47.29 lb. 82.5 lbs.Degree of protection NEMA 4XNight time consumption < 1 WInverter topology TransformerlessCooling Variable speed fanInstallation Indoor and outdoor installationAmbient operating temperature range -40 - 131°F (-40 - 55°C) -40 - 140°F (-40 - 60°C)Permitted humidity 0 - 100 %

DC connection terminals4x DC+ and 4x DC- screw terminals for copper (solid / stranded /

fine stranded) or aluminum (solid / stranded)4x DC+1, 2x DC+2 and 6x DC- screw terminals for copper (solid /

stranded / fine stranded) or aluminum (solid / stranded)AC connection terminals Screw terminals 12 - 6 AWGRevenue Grade Metering Optional (ANSI C12.1 accuracy)

Certificates and compliance with standards

UL 1741-2010, UL1998 (for functions: AFCI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE

C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1

-2013

UL 1741-2015, UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEEC62.41, FCC Part 15 A & B, NEC Article 690-2014, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL

M-07 Issue 1 -2013

PROTECTIVE DEVICES STANDARD WITH ALL PRIMO MODELS

AFCI & 2014 NEC Ready YesGround Fault Protection with Isolation Monitor Interrupter

Yes

DC disconnect YesDC reverse polarity protection Yes

N

W

S

E

INTERFACES STANDARD WITH ALL PRIMO MODELS

Wi-Fi*/Ethernet/Serial Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU

6 inputs or 4 digital inputs/outputs External relay controls

USB (A socket) Datalogging and/or updating via USB

2x RS422 (RJ45 socket) Fronius Solar Net, interface protocol

Datalogger and Webserver Included

*The term Wi-Fi® is a registered trademark of the Wi-Fi Alliance.

Owner
Rectangle
Owner
Rectangle
Owner
Text Box
3) Inverter Data
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 10: Bergh 42.585 KW Planset - Final

Rev. 11.3.15 USA

/ Perfect Welding / Solar Energy / Perfect Charging

v05 May 2015 EN

Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com

WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY./ Whether welding technology, photovoltaics or battery charging technology − our goal is clearly defined: to be the innovation leader. With around 3,300 employees worldwide, we shift the limits of what’s possible - our record of over 900 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. Just as we’ve always done. The responsible use of our resources forms the basis of our corporate policy.

Fronius USA LLC

6797 Fronius Drive

Portage, IN 46368

USA

[email protected]

www.fronius-usa.com

TECHNICAL DATA FRONIUS PRIMO

INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1

Recommended PV power (kWp) 3.0 - 6.0 kW 4.0 - 7.8 kW 4.8 - 9.3 kW 6.1 - 11.7 kW 6.6 - 12.7 kWMax. usable input current (MPPT 1/MPPT 2) 18 A / 18 A 18 A / 18 A 18 A / 18 A 18 A / 18 A 18 A / 18 ATotal max. DC current 36 AMax. array short circuit current (1.25 Imax) (MPPT 1/MPPT 2)

22.5 A / 22.5 A

Operating voltage range 80 V - 600 VMax. input voltage 600 V

Nominal input voltage 410 V 420 V 420 V 420 V 420 V

Admissable conductor size DC AWG 14 - AWG 6

MPP Voltage Range 200 - 480 V 240 - 480 V 240 - 480 V 250 - 480 V 270 - 480 VNumber of MPPT 2

OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1

Max. output power 240 V 3800 W 5000 W 6000 W 7600 W 8200 W

208 V 3800 W 5000 W 6000 W 7600 W 7900 WMax. continuous output current 240 V 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A

208 V 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A

Recommended OCPD/AC breaker size 240 V 20 A 30 A 35 A 40 A 45 A

208 V 25 A 30 A 40 A 50 A 50 A

Max. Efficiency 96.7 % 96.9 % 96.9 % 96.9 % 97.0 %

CEC Efficiency 240 V 95.0 % 95.5 % 96.0 % 96.0 % 96.5 %

Admissable conductor size AC AWG 14 - AWG 6

Grid connection 208 / 240 V

Frequency 60 Hz

Total harmonic distortion < 5.0 %

Power factor (cos φac,r) 0.85-1 ind./cap

INPUT DATA PRIMO 10.0-1 PRIMO 11.4-1 PRIMO 12.5-1 PRIMO 15.0-1

Recommended PV power (kWp) 8.0 - 12.0 kW 9.1 - 13.7 kW 10.0 - 15.0 kW 12.0 - 18.0 kWMax. usable input current (MPPT 1/MPPT 2) 33.0 A / 18.0 ATotal max. DC current 51 AMax. array short circuit current (1.25 Imax) (MPPT 1/MPPT 2) 41.3 A / 22.5 AOperating voltage range 80 V - 600 VMax. input voltage 600 V

Nominal input voltage 415 V 420 V 425 V 440 V

Admissable conductor size DCAWG 14 - AWG 6 copper direct, AWG 6 aluminum direct (AWG 10 copper or AWG 8 aluminium for overcurrent protective devices

up to 60A, from 61 to 100A minimum AWG 8 for copper or AWG 6 aluminium has to be used), AWG 4 - AWG 2 copper or alu-minum with optional input combiner

MPP Voltage Range 220 - 480 V 240 - 480 V 260 - 480 V 320 - 480 VIntegrated DC string fuse holders 4- and 4+ for MPPT 1 / no fusing requried on MPPT 2Number of MPPT 2

OUTPUT DATA PRIMO 10.0-1 PRIMO 11.4-1 PRIMO 12.5-1 PRIMO 15.0-1

Max. output power 240 V 9995 W 11400 W 12500 W 15000 W

208 V 9995 W 11400 W 12500 W 13750 WMax. continuous output current 240 V 41.6 A 47.5 A 52.1 A 62.5 A

208 V 48.1 A 54.8 A 60.1 A 66.1 A

Recommended OCPD/AC breaker size 240 V 60 A 60 A 70 A 80 A

208 V 70 A 70 A 80 A 90 A

Max. Efficiency 96.7 %

CEC Efficiency 96.0 % 96.5 %

Admissable conductor size ACAWG 10 - AWG 2 copper (solid / stranded / fine stranded)(AWG 10 copper or AWG 8 aluminium for overcurrent protective devices

up to 60A, from 61 to 100A minimum AWG 8 for copper or AWG 6 aluminium has to be used) , AWG 6 - AWG 2 copper(solid / stranded) MultiContactWiringable with AWG 12

Grid connection 208 / 240 V

Frequency 60 Hz

Total harmonic distortion < 2.5 %

Power factor (cos φac,r) 0-1 ind./cap.

Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Rectangle
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 11: Bergh 42.585 KW Planset - Final

SE_ToW_EN_US_0415 1/2

FRONIUS LIMITED WARRANTY

TERMS AND CONDITIONS

valid from: 10/15/2015 These limited warranty terms and conditions apply to original installation of Fronius inverters in the United States of America. The warranty agreement is concluded between Fronius and the warranty holder (owner of the installed system).

Content of the warranty:

Fronius Warranty Plus/Warranty Extension Plus

The Fronius Warranty Plus/Warranty Extension Plus covers the costs of materials, servicing and transport under the terms and conditions indicated below.

Fronius Warranty/Warranty Extension

The Fronius Warranty/Warranty Extension covers the costs of materials under the terms and conditions indicated below.

Duration of warranty:

In each case the warranty period begins the day that the products leave the Fronius factory.

Fronius string inverters (wall-mounted devices)

Fronius string inverters are supplied with a 10-year Fronius Warranty Plus.

Fronius central inverters (free-standing devices)

Fronius central inverters are supplied with a 5-year Fronius Warranty Plus.

Fronius Rapid Shut-down Box (RSB)

Fronius Rapid Shut-down boxes are supplied with a 5-year Fronius Warranty Plus.

Warranty services:

If a fault should occur during the Fronius warranty period and the fault is covered by the limited warranty terms and conditions, Fronius reserves the right to make the corresponding spare parts available, make an equivalent replacement device available, repair this fault at its premises or on the customer's

premises, or have these services carried out by a suitably-trained

Fronius Service Partner.

Materials

"Materials" means that, during the warranty period, Fronius will bear the cost of materials (spare part or replacement

device excluding labour costs) associated with the warranty service.

Servicing

The warranty covers the labour costs associated with the materials, provided that these are incurred by Fronius itself or a Fronius Service Partner (service fee). Other incidental costs (such as travel costs, installation costs, if these exceed the Fronius service fee, customs duties, etc.) are not covered by the warranties.

Transport

National transport costs are covered by the Fronius Warranty Plus and Fronius Warranty Extension Plus, provided that these are incurred in accordance with the standard claim procedures with the Fronius Service Provider. Fronius will not bear the costs of any unjustified or express deliveries.

General provisions

Devices or components are to be returned in the original or equivalent packaging. Fronius retains ownership of replacement devices and components inside or outside of the warranty/warranty exclusion until the faulty parts/devices have been received. In all cases ownership of the faulty device/parts is transferred to Fronius when the replacement device is received. If the faulty device/parts is/are not returned to Fronius within 60 days, they will be charged to the installer at the current replacement prices.

Fronius Warranty Extension/Warranty Extension Plus

An extended warranty can be purchased up to 30 months after dispatch by Fronius. Fronius may reject orders received later. The extended warranties only apply to Fronius inverters unambiguously identified by their serial number. It is possible to extend the warranty to 10, 15 or 20 years from dispatch by Fronius.

Considerations when making a warranty claim

First contact an installer, who will then contact Fronius if necessary. The Fronius warranty procedure must be strictly adhered to in the event of a warranty claim. This is the only way of ensuring that the warranty services remain free of charge for the warranty holder. The purchase invoice, serial number of the device and start-up report (the date on which the device was provided/commissioned and report from the power supply company), as well as proof of payment of the warranty extension fee, are required for warranty claims. The purchase price must have been paid to Fronius in full in order for the warranty service to be provided. When devices or components are replaced, the remaining warranty period is transferred to the replacement device or

Owner
Rectangle
Owner
Text Box
4) Inverter Warranty Data
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 12: Bergh 42.585 KW Planset - Final

SE_ToW_EN_US_0415 2/2

replacement component. This is automatically registered at Fronius. A new certificate is not issued. If servicing is carried out on site, the client must guarantee unrestricted access to the Fronius inverters. If necessary, the warranty holder must make the equipment required by the applicable health and safety regulations available free of charge.

Scope and validity of the warranty

The Fronius warranties apply only to Fronius products that have been identified unambiguously by their serial number. These must be appropriately certified for the country of installation. The other components of the photovoltaic system as well as the system add-ons, system monitoring and data communication components, any accessories, and pre-production devices are excluded from the warranty. These components fall under the corresponding provisions of the applicable General Delivery and Payment Conditions of Fronius.

Exclusions from the Fronius warranties

Failure to observe the operating instructions, installation instructions or maintenance procedures. Improper installation Improper commissioning Improper transportation Improper or incorrect operation Inadequate ventilation of the device Any work performed on the device by companies or

persons that have not been authorised by Fronius Failure to observe safety rules and installation standards Force majeure (storm, lightning, overvoltage, fire, etc.) Damage to the Fronius inverter caused by other components in the photovoltaic system or damage that does not impair the function of the Fronius inverter ("cosmetic flaws") is also excluded from the warranty. The warranty does not cover travel and accommodation expenses as well as on-site assembly and installation costs, if these exceed the service reimbursement paid to the installer by Fronius depending on the service and agreement. Changes to the existing PV system, in-house installation and similar or the time involved and the costs incurred are not covered by the warranty. Due to technological progress, the equivalent replacement or new device provided may not be compatible with the system monitoring or other components installed on site (e.g. Fronius DATCOM). The warranty does not cover the expenses and costs incurred as a result of upgrading system monitors or other components of the PV system.

A claim for compensation cannot be made for energy that has not been fed into the grid or energy that has not been consumed in-house, etc. Fuses and other wearing parts are excluded from the warranty. Other legal information

SELLER DISCLAIMS ALL IMPLIED WARRANTIES AND SIMILAR OBLIGATIONS (OTHER THAN THAT THE GOODS WILL BE NEW AND GOOD TITLE) INCLUDING BUT NOT LIMITED TO THOSE OF FITNESS FOR A PARTICULAR PURPOSE, AND MERCHANTABILITY, WHETHER OTHERWISE ARISING BY LAW, CUSTOM, USAGE, TRADE PRACTICE, COURSE OF DEALING, OR COURSE OF PERFORMANCE. There are no warranties which extend beyond those express warranties contained in the Agreement. Buyer affirms that it has not relied upon Seller’s skill nor judgment to select or furnish the Goods for any particular purpose beyond the specific express warranties in the Agreement. Seller does not warrant the Goods will comply with the requirements of any safety or environmental code or regulation of any federal, state, municipality or other jurisdiction beyond the specific express warranties in the Agreement. Seller does not warrant that the Goods will operate with any accessories or within any system not sold under the Agreement and Seller’s warranty is limited to the operation of the Goods in a stand-alone mode. Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers, or the limitation of liability for personal injury, so such limitations and exclusions may be limited in their application to an end user and others. When the implied warranties are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty. The warranty gives specific legal rights which may vary depending on local law.

Other legal warranty or liability claims against Fronius remain unaffected by this warranty. In the event of such claims, please contact the vendor of your device. Our General Delivery and Payment Conditions under "Legal information" on our website (www.fronius.com) also apply. Previously valid warranty conditions are replaced by these conditions. Fronius reserves the right to make changes to the warranty process at any time. Current and detailed information about warranty terms and conditions can be found on our website at www.fronius.com/solar/warranty

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 13: Bergh 42.585 KW Planset - Final

LGate 120 RESIDENTIAL SOLAR MONITORING SOLUTION

Product Datasheet

The LGate 120 is a single-phase electronic watt-hour meter for remote monitoring of solar photovoltaic systems. It features a smart communications module to automatically transmit meter data over cellular or Ethernet networks allowing system owners and operators to easily manage distributed solar assets.

The LGate 120 combines a revenue-grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers.

DATA COLLECTION

AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms.

NETWORK CONNECTIVITY

The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable.

FEATURES

• ANSI C12.20 power meter • RS-485 and Zigbee inputs • GSM cellular or Ethernet connectivity • Over the air firmware updates

• Easy, low cost installation • Doesn’t require entrance into the building • Plug and play activation • LCD display

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Owner
Text Box
5) Monitor Data
Page 14: Bergh 42.585 KW Planset - Final

DATALOGGER

Processor ARM9 embedded CPU

OS Custom version of Linux 2.6, OTA firmware updates

Memory 128 MB RAM

Display LCD screen

SPECIFICATIONS

COMMUNICATIONS

LAN RJ45 10/100 Ethernet, full half duplex, auto polarity

Cellular 3G GSM

Networking DHCP or static

PHYSICAL

Enclosure NEMA 3R Type

Weight 8 oz

Dimensions 6.95” x 6.5” x 7.3”

Environment -20 to 60C, all-weather

Warranty 5 year limited warranty

DIAGRAM – TYPICAL CONFIGURATION

DIMENSIONS

I/O

RS485 2 wire and 4 wire

Modbus

Zigbee

Shielded CAT5

LEGEND

6.95 in

6.31 in

5.46 in

6.00 in

7.30 in

SOCKET METER

COMPLIANCE

ANSI 12.20 class 0.2%

FCC Part 15B

PTCRB

AT&T Carrier Compliance

PV ARRAY

ELECTRICALSERVICE

INVERTER(S)

INTERNET

LGATE 120

METER BASE METER MODULELOCUS ENERGYCOMM MODULE

POWER

Accuracy ANSI 12.20 (Class 0.2%)

Voltage Inputs 120 - 480 VAC

Max. Current Input 200 A

Service Type Single phase , 60 Hz

Socket Type 2S

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 15: Bergh 42.585 KW Planset - Final

Product Data Sheet D324NRBSafety Switch , 200A, Fusible, Cartridge (Class H,K or R), 3-Pole

List Price $1,461.00 USD

Availability Stock Item: This item is normally stocked in our distribution facility.

Terminal Type Lugs

Type of Duty General Duty

Maximum Voltage Rating 240VAC

Wire Size #2 to 300 AWG/kcmil(Al) - #4 to 300 AWG/kcmil(Cu)

Depth 8.25 Inches

Height 29.25 Inches

Width 17.25 Inches

Action Single Throw

Ampere Rating 200A

Approvals UL Listed File: E2875

Enclosure Rating NEMA 3R

Enclosure Type Rainproof and Sleet/Ice proof (Indoor/Outdoor)

Enclosure Material Galvannealed Steel

Factory Installed Neutral Yes

Fuse Type Cartridge (Class H, K or R)

Disconnect Type Fusible

Short Circuit Current Rating 100kA (max. depending on fuse type)

Mounting Type Surface

Number of Poles 3-Pole

Technical Characteristics

Category 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R

Discount Schedule DE1A

GTIN 00785901461524

Package Quantity 1

Weight 45.33 lbs.

Availability Code Stock Item: This item is normally stocked in our distr bution facility.

Returnability Y

Country of Origin US

Shipping and Ordering

As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.

Generated: 06/30/2010 15:08:04

© 2010 Schneider Electric. All rights reserved.

1

Owner
Text Box
6) Disconnect Data
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 16: Bergh 42.585 KW Planset - Final

1 of 11

¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.

¡ TEST CRITERIA: 3 PROTOTYPE TESTED 3 NEMA MG1-22 EVALUATION 3 SYSTEM TORSIONAL TESTED 3 MOTOR STARTING ABILITY

¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.

¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.

¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

INCLUDES:

• Two Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position.

• True Power™ Electrical Technology

• Isochronous Electronic Governor

• Sound Attenuated Enclosure

• Closed Coolant Recovery System

• Smart Battery Charger

• UV/Ozone Resistant Hoses

• ±1% Voltage Regulation

• Natural Gas or LP Operation

• 5 Year Limited Warranty

• UL 2200 Listed

Standby Power Rating

Model RG022 (Aluminum - Gray) - 22 kW 60 HzModel RG027 (Aluminum - Gray) - 27 kW 60 HzModel RG032 (Aluminum - Gray) - 32 kW 60 HzModel RG038 (Aluminum - Gray) - 38 kW 60 HzModel RG048 (Aluminum - Gray) - 48 kW 60 Hz

FEATURES

ISO9001:2008

PROTECTOR® QS SERIESStandby Generators

Liquid-Cooled Gaseous Engine

Pro

tect

or®

QS

Ser

ies

Protector® QS Series

Meets EPA Emission Regulations22 & 27 kW are CA/MA emissions compliant

48 kW meets CA/MA emissions requirements with optional catalyst32 & 38 kW not for sale in CA/MA

®

*Built in the USA using domestic and foreign parts

Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Owner
Text Box
7) Generator Data
Page 17: Bergh 42.585 KW Planset - Final

2 of 11

22 • 27 • 32 • 38 • 48 kW application & engineering data

GENERATOR SPECIFICATIONSType Synchronous

Rotor Insulation ClassH (22 & 27 kW) or

F (32, 38 & 48 kW)

Stator Insulation Class H

Telephone Interference Factor (TIF) <50

Alternator Output Leads 1-Phase 4 wire

Alternator Output Leads 3-Phase 6 wire

Bearings Sealed Ball

Coupling Flexible Disc

Excitation System Direct

VOLTAGE REGULATIONType Electronic

Sensing Single Phase

Regulation ± 1%

GOVERNOR SPECIFICATIONSType Electronic

Frequency Regulation Isochronous

Steady State Regulation ± 0.25%

ELECTRICAL SYSTEMBattery Charge Alternator 12 Volt 30 Amp

Static Battery Charger 2.5 Amp

Recommended Battery (battery not included)Group 26 (22, 27, 32 & 38 kW)

or Group 24F (48 kW), 525CCA

System Voltage 12 Volts

GENERATOR FEATURESRevolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120 °C above a 40 °C ambientClass H insulation is NEMA ratedClass F insulation is NEMA ratedAll models fully prototyped tested

ENCLOSURE FEATURES

�Aluminum weather protective enclosure

Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.

�Enclosed critical grade muffler

Quiet, critical grade muffler is mounted inside the unit to prevent injuries.

�Small, compact, attractive Makes for an easy, eye appealing installation.

SAE Sound attenuated enclosure ensures quiet operation.

ENGINE SPECIFICATIONS: 22, 27, 32 & 38 kWMake Generac

Model In-line

Cylinders 4

Displacement (Liters) 2.4

Bore (in/mm) 3.41/86.5

Stroke (in/mm) 3.94/100

Compression Ratio 9.5:1

Intake Air System

Naturally Aspirated (22 & 27 kW) or

Turbocharged/Aftercooled

(32 & 38 kW)

Lifter Type Hydraulic

ENGINE SPECIFICATIONS: 48 kWMake Generac

Model V-Type

Cylinders 8

Displacement (Liters) 5.4

Bore (in/mm) 3.55/90.2

Stroke (in/mm) 4.17/105.9

Compression Ratio 9:1

Intake Air System Naturally Aspirated

Lifter Type Hydraulic

ENGINE LUBRICATION SYSTEMOil Pump Type Gear

Oil Filter Type Full flow spin-on cartridge

Crankcase Capacity (qt/l)4/3.8 (22, 27, 32 & 38 kW) or

6/5.7 (48 kW)

ENGINE COOLING SYSTEMType Closed

Water Pump Belt driven

Fan Speed (rpm)

1980 - 22 & 27 kW

1500 - 32 & 38 kW

1954 - 48 kW

Fan Diameter (in/mm)18.1/459.7 (22 & 27 kW) or

22/558.8 (32, 38 & 48 kW)

Fan ModePusher (22 & 27 kW) or

Puller (32, 38 & 48 kW)

FUEL SYSTEMFuel Type Natural gas, propane vapor

Carburetor Down Draft

Secondary Fuel Regulator Standard

Fuel Shut Off Solenoid Standard

Operating Fuel Pressure 5-14" water column/9-26 mm HG

(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)

Pro

tect

or®

QS

Ser

ies ®

Owner
Highlight
Owner
Highlight
Page 18: Bergh 42.585 KW Planset - Final

3 of 11

22 • 27 • 32 • 38 • 48 kW operating data

GENERATOR OUTPUT VOLTAGE/kW - 60 HzkW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)

RG022

120/240 V, 1Ø, 1.0 pf 22 92 22 92 100

120/208 V, 3Ø, 0.8 pf 22 76 22 76 80

120/240 V, 3Ø, 0.8 pf 22 66 22 66 80

RG027

120/240 V, 1Ø, 1.0 pf 27 113 25 104 125

120/208 V, 3Ø, 0.8 pf 27 94 25 87 100

120/240 V, 3Ø, 0.8 pf 27 81 25 75 90

RG032

120/240 V, 1Ø, 1.0 pf 32 133 32 133 150

120/208 V, 3Ø, 0.8 pf 32 111 32 111 125

120/240 V, 3Ø, 0.8 pf 32 96 32 96 100

277/480 V, 3Ø, 0.8 pf 32 48 32 48 60

RG038

120/240 V, 1Ø, 1.0 pf 38 158 38 158 175

120/208 V, 3Ø, 0.8 pf 38 132 38 132 150

120/240 V, 3Ø, 0.8 pf 38 114 38 114 125

277/480 V, 3Ø, 0.8 pf 38 57 38 57 60

RG048

120/240 V, 1Ø, 1.0 pf 48 200 48 200 200

120/208 V, 3Ø, 0.8 pf 48 167 48 167 175

120/240 V, 3Ø, 0.8 pf 48 144 48 144 150

277/480 V, 3Ø, 0.8 pf 48 72 48 72 80

SURGE CAPACITY IN AMPSVoltage Dip @ < .4 pf

15% 30%

RG022

120/240 V, 1Ø 55 135

120/208 V, 3Ø 40 92

120/240 V, 3Ø 35 80

RG027

120/240 V, 1Ø 62 170

120/208 V, 3Ø 70 120

120/240 V, 3Ø 61 103

RG032

120/240 V, 1Ø 75 180

120/208 V, 3Ø 87 210

120/240 V, 3Ø 75 182

277/480 V, 3Ø 36 87

RG038

120/240 V, 1Ø 75 180

120/208 V, 3Ø 87 210

120/240 V, 3Ø 75 182

277/480 V, 3Ø 36 87

RG048

120/240 V, 1Ø 85 195

120/208 V, 3Ø 90 218

120/240 V, 3Ø 78 189

277/480 V, 3Ø 36 87

ENGINE FUEL CONSUMPTIONNatural Gas Propane

(ft³/hr) (m³/hr) (gal/hr) (l/hr) (ft³/hr)

RG022

Exercise cycle 42 1.2 0.44 1.7 16

25% of rated load 100 2.8 1.1 4.2 40

50% of rated load 190 5.4 2.1 7.8 75

75% of rated load 255 7.2 2.8 10.5 101

100% of rated load 316 9 3.4 13 125

RG027

Exercise cycle 42 1.2 0.44 1.7 16

25% of rated load 108 3.1 1.2 4.5 43

50% of rated load 197 5.6 2.1 8.1 78

75% of rated load 287 8.2 3.1 11.8 114

100% of rated load 359 10.2 3.9 14.8 143

RG032

Exercise cycle 79 2.2 0.8 3.2 30

25% of rated load 144 4.1 1.7 6.3 60

50% of rated load 226 6.4 2.7 10.3 97

75% of rated load 298 6.4 3.7 13.9 132

100% of rated load 375 10.6 4.6 17.5 166

RG038

Exercise cycle 83 2.3 0.9 3.2 31

25% of rated load 162 4.6 1.7 6.6 62

50% of rated load 255 7.2 2.9 10.8 103

75% of rated load 345 9.8 4 15 142

100% of rated load 437 12.4 5.2 19 185

RG048

Exercise cycle 95 2.7 1 3.9 38

25% of rated load 204 5.8 2.16 8.5 82

50% of rated load 392 11.1 4.14 15.7 151

75% of rated load 547 15.5 5.8 22.8 220

100% of rated load 756 21.5 7.96 31.3 302

Pro

tect

or®

QS

Ser

ies

STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.

Note: Fuel pipe must be sized for full load.

For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG)

For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG)

Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.

®

Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Page 19: Bergh 42.585 KW Planset - Final

4 of 11

22 • 27 • 32 • 38 • 48 kW operating data

Pro

tect

or®

QS

Ser

ies

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

Temperature Deration ...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °FAltitude Deration (22, 27 & 48 kW) .....................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ftAltitude Deration (32 & 38 kW) ....................................................................................... 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft

CONTROLLER FEATURES

2-Line Plain Text LCD Display ........................................................................................................................................Simple user interface for ease of operation.Mode Switch: Auto ..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser

Off ...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual ......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place.

Programmable start delay between 10-30 seconds ............................................................................................................................................................ StandardEngine Start Sequence ..................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)Engine Warm-up ..................................................................................................................................................................................................................... 5 secEngine Cool-Down ..................................................................................................................................................................................................................1 minStarter Lock-out ................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped.Smart Battery Charger ........................................................................................................................................................................................................ StandardAutomatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................ StandardAutomatic Low Oil Pressure Shutdown ............................................................................................................................................................................... StandardOverspeed Shutdown .............................................................................................................................................................................................. Standard, 72 HzHigh Temperature Shutdown ............................................................................................................................................................................................... StandardOvercrank Protection .......................................................................................................................................................................................................... StandardSafety Fused ...................................................................................................................................................................................................................... StandardFailure to Transfer Protection .............................................................................................................................................................................................. StandardLow Battery Protection ........................................................................................................................................................................................................ Standard50 Event Run Log ............................................................................................................................................................................................................... StandardFuture Set Capable Exerciser .............................................................................................................................................................................................. StandardIncorrect Wiring Protection ................................................................................................................................................................................................. StandardInternal Fault Protection ..................................................................................................................................................................................................... StandardCommon External Fault Capability ...................................................................................................................................................................................... StandardGovernor Failure Protection ................................................................................................................................................................................................ Standard

ENGINE COOLING

22 kW 27 kW 32 & 38 kW 48 kW

Air flow (inlet air including alternator and combustion air in cfm/cmm) 2400/68 2400/68 2200/62.3 4350/123.2

System coolant capacity (gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 3/11.4

Heat rejection to coolant (BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 186,000/196.2

Maximum operation air temperature on radiator (°C/°F) 60/150

Maximum ambient temperature (°C/°F) 50/140

COMBUSTION REQUIREMENTS

Flow at rated power (cfm/cmm) 68/1.9 68/1.9 106/3 163/4.6

SOUND EMISSIONS

Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 61 61 58 63

Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 70 70 64 68

*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.

EXHAUST

Exhaust flow at rated output (cfm/cmm) 165/4.7 180/5.1 300/8.5 414/11.7

Exhaust temperature at muffler outlet (°C/°F) 482/900 538/1000 579/1075 552/1025

ENGINE PARAMETERS

Rated Synchronous rpm 1800

®

Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Page 20: Bergh 42.585 KW Planset - Final

5 of 11

22 • 27 • 32 • 38 • 48 kW available accessories

Pro

tect

or®

QS

Ser

ies

Model # Product Description

006463-3 Mobile Link™

Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only.

006478-0 Harness Adapter KitThe Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™.

005630-1 - 22, 27, 32 & 38 kW

005632-1 - 48 kWCold Weather Kit

If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap.

005616-0 - 22, 27, 32 & 38 kW

006204-0 - 48 kWExtreme Cold Weather Kit

Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only.

005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris.

005704-0 Paint KitIf the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure.

005656-0 - 22 & 27 kW

005984-0 - 32 & 38 kW

006205-0 - 48 kW

Scheduled Maintenance Kit

The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators.

006664-0Local Wireless Monitor

Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house.

006665-0Wireless Remote Extension Harness

Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater.

006873-0Smart Management Module (50 Amps)

Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system.

006510-0 E-StopE-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.

®

Owner
Highlight
Owner
Highlight
Page 21: Bergh 42.585 KW Planset - Final

1 of 2

Non-Service RatedAutomatic Transfer Switches 10

0-40

0 A

mps

®

100-400 Amps

100 - 400 Amps, Three Phase

DESCRIPTIONAll non-service rated switches are available in 120/208 3ø, 120/240 3ø, and 277/480 3ø. All switches are open transition.

STANDARD FEATURESAll non-service rated transfer switches are housed in a steel NEMA/UL Type 3R enclosure, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands.

Owner
Text Box
8 Transfer Switch Data
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Owner
Highlight
Owner
Highlight
Page 22: Bergh 42.585 KW Planset - Final

2 of 2

Functions

Dimensions

®

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com©2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0186650SBY-L Printed in U.S.A. 09/23/15

100-400 Amps Non-Service Rated Transfer Switches

®

Model RTSN100G3 RTSN100J3 RTSN100K3 RTSN200G3 RTSN200J3 RTSN200K3 RTSN400G3 RTSN400J3 RTSN400K3

Amps 100 200 400

Voltage 120/208 3Ø 120/240 3Ø 277/480 3Ø 120/208 3Ø 120/240 3Ø 277/480 3Ø 120/208 3Ø 120/240 3Ø 277/480 3Ø

Load Transition Type (Automatic)

Open Transition

Enclosure Type NEMA 3R

Withstand Rating (Amps) 14,000 14,000 14,000 25,000 25,000 25,000 35,000 35,000 35,000

Lug Range 2/0 - #6 400 MCM - #4 600 MCM - #4 or 1/0 - 250 MCM

• Electrically operated, mechanically-held contacts for fast, positive connections.

• Rated for all classes of load, 100% equipment rated, both inductive and resistive.

• 160 millisecond transfer time.

• Single coil design.

• Main contacts are silver plated or silver alloy to resist welding and sticking.

• NEMA 3R (indoor/outdoor rated) steel enclosure is standard.

• Limited Five Year Warranty.

H2

DEPTH

H1

W2

W1

Specifications

Features

ModelHeight (in./mm) Width (in./mm) Depth

(in./mm)Weight

(lbs./kilos)H1 H2 W1 W2

RTSN100G3 19.3/490.2 24.1/612.1 16.9/429.3 20.2/513.1 7.1/180.3 65/29.48

RTSN100J3 19.3/490.2 24.1/612.1 16.9/429.3 20.2/513.1 7.1/180.3 57/25.85

RTSN100K3 31.3/795 36.1/916.9 19.2/487.7 24/609.6 10/254 135/61.24

RTSN200G3 19.3/490.2 24.1/612.1 16.9/429.3 20.2/513.1 7.1/180.3 48/21.77

RTSN200J3 19.3/490.2 24.1/612.1 16.9/429.3 20.2/513.1 7.1/180.3 65/29.48

RTSN200K3 43/1092.2 48.1/1221.7 25/635 30.1/764.5 13.1/332.7 105/47.63

RTSN400G3 31.3/795 36.1/916.9 19.2/487.7 24/609.6 10/254 160/72.57

RTSN400J3 31.3/795 36.1/916.9 19.2/487.7 24/609.6 10/254 133/60.33

RTSN400K3 43/1092.2 48.1/1221.7 25/635 30.1/764.5 13.1/332.7 133/60.33

100-

400

Am

ps

All timing and sensing functions originate in the generator controller

Utility voltage drop-out ......................................................................................................................................................................................................................<60% Timer to generator start ...................................................................................................................................... 10 second factory set, adjustable between 10-30 seconds Engine warm up delay ................................................................................................................................................................................................................. 5 seconds Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds Utility voltage pickup .........................................................................................................................................................................................................................>80% Re-transfer time delay ............................................................................................................................................................................................................... 15 seconds Engine cool-down timer ............................................................................................................................................................................................................ 60 seconds Exerciser ............................................................................................................................................................................................................ 12 minutes every 7 days*

*Function of the controller

The transfer switch can be operated manually without power applied.

Owner
Typewritten Text
Owner
Typewritten Text
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Highlight
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 23: Bergh 42.585 KW Planset - Final
Owner
Text Box
9) Attachment Data
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 24: Bergh 42.585 KW Planset - Final
Owner
Rectangle
Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 25: Bergh 42.585 KW Planset - Final

TITLE

DRAWING NO DRAWN BY

S-5! ProteaBracket

ProteaBracket_CCD_2012 DMMH 12/5/2012DATE

MATERIAL:

SUPPLIED HARDWARE:

OTHER:

A2 Stainless

(4) 6mm X 25mm (8mm Hex W/Washer)

The Right Way!

METAL ROOF INNOVATIONS, LTD.8655 TABLE BUTTE RD

COLORADO SPRINGS, CO 80908719-495-0518

719-495-0045 (FAX)

EST ASSEMBLY WEIGHT :

.526 lbs

SCALE:

1:1

Bi Metal Sheet Screw

S-5!® PRODUCTS ARE PROTECTED BY MULTIPLE U S PATENTS INCLUDING 5,228,248, 5,983,588 AND6,164,033 (OTHERS ISSUED AND PENDING) EUROPEAN PATENTS ARE ALSO APPLIED FOR AND PENDING

UNDER THE PATENT COOPERATION TREATY WITH DIVISIONAL FILING RIGHTS RETAINED METAL ROOFINNOVATIONS, LTD (LICENSOR OF S-5!® TECHNOLOGY) AGGRESSIVELY PROSECUTES PATENT

INFRINGEMENT

FRONTLEFT RIGHT

TOP

FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST INFORMATION AND CLAMP INSTALLATION INFORMATION PLEASE VISIT: WWW.S-5.COM

ProteaBracket

.76"[19]

.97"[25]

.33"[8]

.43"[11]

Factory Applied Sealant

.15"[4]

.77"[20]

.77"[20]

.39"[10]

2.27"[58]

1.61"[41]

2.61"[66]

2.39"[61]

3.93"[100]

1.00"[25]

.33"[8]

Thru Hole 4x.27" / [7]

.34"[9] 1.45"

[37]

L

k

dc f

d1

k5.5.22

dc6

.24

L251

d116.63

f8

.30MM

INCH

6mm X 25mm (8mm Hex W/16mm Washer)

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 26: Bergh 42.585 KW Planset - Final

The

right

way

to a

ttach

alm

ost a

nyth

ing

to m

etal

roof

s! S-5-

PV K

it an

d Ed

geG

rab™

888-

825-

3432

| w

ww

.S-5

.com

|

S-5-PV Kit and EdgeGrab™

The concept of combining photovoltaic arrays with standing seam metal roofing is growing—and for good reasons. A standing seam metal roof has a life expectancy consistent with that of framed PV modules. A 30-year power source on a 40-year roof, along with zero-penetration technology, creates the most sustainable roof system available with alternative power generation, all without compromising the roof manufacturer's warranty!

The new S-5-PV Kit boasts an important breakthrough in PV mounting technology. It is one of the first solar module mounting solutions in the industry to be listed to the new UL subject 2703, a standard that covers both bonding and mounting. Furthermore, the S-5!® Mounting Disk has gained an ETL Listing to UL 1703.*

The S-5-PV Kit features a groundbreaking new stainless steel mounting disk with twelve nodes designed to ensure the module-to-module conductivity of anodized aluminum module frames. This means it automatically provides a ground path in the module frame. No lugs or wire required except to connect one string of modules to another and to ground the system. This connection detail represents installed electrical cost savings of $6-$12 per unit. In most cases, the savings in time and materials is sufficient to pay for the entire S-5-PV Kit and clamp setup.

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 27: Bergh 42.585 KW Planset - Final

Distributed byS-5!® Warning! Please use this product responsibly!Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data regarding holding strength.

Copyright 2015, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 052115.

The S-5-PV Kit is a revolutionary new solution to attach solar PV panels to standing seam metal roofs!

R

S-5-PV Kit(UL and ETL Listed)

EdgeGrab™(Not UL or ETL Listed)

R

0.47"(12.00 mm)

1.50"(38.00 mm)

Wire Zip Tie SlotsModule Placement Bevel Guide

Friction Reducing Coated Stainless Steel Universal PV Stud w/ M8 Integral Hex Nut

3.00"(76.00 mm) ETL Listed

Mounting DiscStud

Height2.67"

(68.00 mm)

† Hold Min/Max1.18"-1.89"

(30.00-48.00 mm)

0.06"(1.50 mm)

0.48"(12.19 mm)

1.50"(38.10 mm)

0.84"(21.34 mm)

2.00"(50.80 mm)

1.00"(25.00 mm)

0.71"(18.00 mm)

0.87"(22.00 mm)

WireManagementHooks

1 2 3

The S-5-PV Kit is furnished with the hardware shown at right, excluding the attachment clamp, which is supplied separately. (When ProteaBracket™ is used in conjunction with the S-5-PV Kit, an additional nut is required during installation to secure the universal PV stud and mounting disk to ProteaBracket's slotted L-flange.) The S-5-PV Kit is compatible with most common metal roofing materials, including brass. The S-5!® EdgeGrab™ and S-5-PV Kit together accommodate PV frame thicknesses 30–48 mm (if EdgeGrab's serrated L-flange is positioned below the stud's hex nut) and 34–51 mm (if EdgeGrab's serrated L-flange is positioned above the stud's hex nut).†

The embossed panel guide makes the module placement easier. The mounting disk is multi-directional and rails are not required.

Four strategically placed under-disk hooks assist in wire management. The PV grab ears that hold the solar panel in place are broader to allow for ease of installation and precise module engagement.

Accommodating module thicknesses between 30 and 51 mm, the S-5-PV Kit fits the majority of solar panels on the market. Using the S-5! mini clamps, it fits most standing seam metal roofs. When paired with other S-5! products, the S-5-PV Kit and EdgeGrab will work on most exposed-fastened and corrugated metal roofs. The standard grab is designed to fit field conditions (two adjacent panels), while the new EdgeGrab is designed specifically for end conditions.

Wind dynamics are complex; thus, each system should be reviewed by a qualified licensed professional who understands wind effects on metal roof design and construction prior to purchase and installation. For more detailed information including specifications, installation instructions, and CAD drawings, visit www.S-5.com or your S-5-PV Kit distributor.

The S-5-PV Kit continues to be the easiest, most cost-effective way to install solar panels directly to standing seam metal roofs, remaining the most popular choice worldwide.

Please note: All measurements are rounded to the second decimal place.

* Patents pending. Certain components featured in illustration may not be UL listed.Due to the variety of attachment needs, S-5-PV Kits are sold separately from S-5! mini clamps. The S-5-PV Kit fits only S-5! mini clamps, NOT standard clamps.

Listed to UL subject 2703.ETL Listed to UL 1703.*

Please Note: Dimensions of both the Universal PV Stud and the Mounting Disk are identical between these two illustrations.

Please note: The assembly option in the diagram to the right illustrates he serrated L-flange positioned below the stud's hex nut.

S-5! clamp not included.

S-5! clamp not included.

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW
Page 28: Bergh 42.585 KW Planset - Final

LE

SCALE

DRAWING NO. DRAWN BY

PV Kit 30 Components CCD v2012

DMMH 10/25/2011

1:1 FILE NAME CCD

DATE

ALLOY:

EST. AREA:

EST. WT/FT:

FINISH:

CUT LENGTH:

S-5! ATTACHMENT SOLU ONSME AL ROOF NNOVA ONS, L D.

8655 ABLE BUTTE ROADCOLORADO SPRINGS, CO 80908

(888) 825-3432(719) 495-0045 ( AX)

P

J

K

60°

DETAILS HEADDIA

A

HEADHI

H

WID HACROSS

CORNERS

Wmin

MAJORDIA

D JSIZE

M8 12.7513.00

3.673.97 14.38 7.760

7.97213.6013.77

MAJORDIA

F

6.2726.438

H

OPPOSED DIRECTIONOF CLOCK-WISEW/SERRATN 19T

F D

K

67.8268.50

PITCH

P

1.25

H

A

B

W

E

H

h

15º 25º

OPPOSED DIRECTIONOF CLOCK-WISEW/SERRATN 24T

DETAILS HEADDIA

A

HEADHI

H Emin

hmin

Wmin

WASHERDIA

BSIZE

M8 12.7513.00

7.858.35 3.20 1.50 14.28 17.00

18.00

W

A

ASSEMBLED EDGE CONDITION ASSEMBLED MID CONDITION

3" MOUNTING DISC

UNIVERSAL PV STUD

M8 HEX FLANGE NUT

PV GRAB 30

S-5-PV KIT ASSEMBLES TO ANY S-5 MINI CLAMP

Ø10.16mmTHRU HOLE

.800.475

SYM

873

.714

1.000

1.500

873

300 SERIES STAINLESS

300 SERIES STAINLESS

6000 SERIESALUMINUM

300 SERIES STAINLESS

Ø 3 000"

.220"

250"Ø 330"

1.125"

.035"

Owner
Text Box
Missouri Sun Solar: Bergh Solar Project 49.585kW