Page 1: Basic Panels & Accessories

V A R C O P R U D E N B U I L D I N G S

Basic Panels & Accessories

The field guide for correct installation of Varco Pruden’s Wall and Roof Systems, Tuff-Lites, Wallites, Doors, Windows, Gutters and Trim.

Page 2: Basic Panels & Accessories

This page intentionally left blank.

Page 3: Basic Panels & Accessories

INDEX

SECTION TOPIC

FASTENERS FASTENER IDENTIFICATION ROOF FASTENERS WALL FASTENERS

SHEETING ROOF MASTIC MASTIC & SHEETING-ROOF FASTENER APPLICATION-ROOF SIDEWALLS ENDWALLS

TUF-LITE TUF-LITE UL90 INSULATION WALK DOOR CANOPY OVERHEAD DOORS LOUVERS VENTILATORS LINER PANELS PURLIN & GIRT CLOSURES

TRIM CORNER CLOSURES STANDARD TRIMS PEAK CAP EAVE GUTTER & DOWNSPOUTS MULTI-GUTTER HARD RUBBER INSIDE CLOSURE PLUG PANEL CLOSURES

C

D

A

ACCESSORIES

INDEX 03/15/14

A1A2A3-A4

B4-B6B7-B14B15B16-B17

C1-C2C3-C4C5-C6C7C8C9-C10C11-C12C13-C16C17

D1D2-D3D4D5-D8 D9-D10D11D12

NOTE: BUILDING PLANS AND SED'S SUPERCEDE INSTALLATION GUIDE.

B1-B2B3

SEE SED'S FOR SPECIFIC PART NUMBERS AND SEALANTS REQUIREMENTS.

Page 4: Basic Panels & Accessories

FASTENER APPLICATION

#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/5

8" O.D. SEALING WASHER

(1 12" OPTIONAL)

14-14 x 7 8" SELF - DRILL

STITCH FASTENERW/ 5 8" O.D. SEALINGWASHER

#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/7

8" O.D. SEALING WASHER

(1 12" OPTIONAL)

18" BLIND RIVET

14 - 14 x 1 1/8" SELF - DRILLSTITCH FASTENERW/ 78" O.D. SEALING WASHER

VP-205 RIVET

PANEL TO STRUCTURALCONNECTIONS

TUF-LITE INSTALLATION(UL-60)

PANEL TO PANELCONNECTIONS

PANEL TO STRUCTURALCONNECTIONS

PANEL TO PANELCONNECTIONS

PANEL TO STRUCTURALCONNECTIONS

TRIM TO STRUCTURALS

PANEL TO PANELCONNECTIONS

TRIM TO PANELS

LOUVERS

WALL LITES

BUILDING TRIM, EAVEGUTTER LAPS & CLOSURES

TUF-LITE INSTALLATION(UL-60)

TUF-LITE INSTALLATION(UL-90)

CHECK THE WAREHOUSE SHIPPING LIST FOR THE TYPE AND NUMBER OF FASTENERS SHIPPED.THE ABOVE INFORMATION IS TO BE USED AS AN IDENTIFICATION GUIDE FOR THE PROPERAPPLICATION OF EACH TYPE OF FASTENER.

1.2.

ROOF

ROOF

ROOF

ROOF

WALL

WALL

MISC.

MISC.

FASTENER IDENTIFICATION / APPLICATION GUIDEA-1

03/15/14

#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/5

8" O.D. SEALING WASHER

14-14 x 7 8" SELF - DRILL

STITCH FASTENERW/ 5 8" O.D. SEALINGWASHER

GUTTER

TUF-LITE INSTALLATION(UL-90)

#17/12-14 x 1 7/8" SELF -DRILL STRUCTURALSTAND-OFF FASTENER W/ 5 8"O.D. SEALING WASHER

WALL

PANEL TO STRUCTURALCONNECTIONS WITHGREATER THAN 4" BLANKETINSULATION (EXCEPT ATCRIMPED BASE AND ATFRAMED OPENINGS)

Page 5: Basic Panels & Accessories

58" ROOF

SEALING WASHER

NONWALKING-HIGH

SPEED DRILL POINT

DEEP THREADS DRAWPANELS SECURELY

TOGETHER

LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.

1/4-14 X 7 8"SELF-DRILLING

STITCH FASTENER

12-14 X 1 14"(1 12" OPTIONAL)SELF-DRILLINGSTRUCTURAL

FASTENER

TAPE SEALANT

ROOFPANELLAP

PURLINPURLIN BEARING

EDGE

SECTION THROUGH ROOFSHOWING CORRECT

FASTENER APPLICATION

AFTER PRE-DRILLING, METALSHAVINGS MUST BE CLEANED FROM

PANEL SURFACE TO PREVENTCORROSION.

NOTE:

PANEL TOSTRUCTURALAPPLICATION

PANEL TOPANEL

APPLICATION

STANDARD ROOF FASTENERSA-2

03/15/14

Page 6: Basic Panels & Accessories

SECTION THROUGH WALLSHOWING CORRECTFASTENER APPLICATION

AFTER PRE-DRILLING, METAL SHAVINGSMUST BE CLEANED FROM PANELSURFACE TO PREVENT CORROSION.

NOTE:

STANDARD WALL FASTENERS WITH 4" OR LESS INSULATIONA-3

03/15/14

58" ROOF

SEALING WASHER

NONWALKING-HIGH

SPEED DRILL POINT

DEEP THREADS DRAWPANELS SECURELY

TOGETHER

LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.

1/4-14 X 7 8"SELF-DRILLING

STITCH FASTENER

12-14 X 1 14"(1 12" OPTIONAL)SELF-DRILLINGSTRUCTURAL

FASTENER

WALLPANELLAP

GIRT

PANEL TOSTRUCTURALAPPLICATION

PANEL TOPANEL

APPLICATION

PRE-DRILLING ISRECOMMENDED.

Page 7: Basic Panels & Accessories

SECTION THROUGH WALLSHOWING CORRECTFASTENER APPLICATION

AFTER PRE-DRILLING,METAL SHAVINGS MUSTBE CLEANED FROMPANEL SURFACE TOPREVENT CORROSION.

NOTE:

STANDARD WALL FASTENERS WITH OVER 4" INSULATIONA-4

03/15/14

58" ROOF

SEALING WASHER

NONWALKING-HIGH

SPEED DRILL POINT

DEEP THREADS DRAWPANELS SECURELY

TOGETHER

LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.

1/4-14 X 7 8"SELF-DRILLING

STITCH FASTENER

17/12-14 X 1 7/8"SELF-DRILLING

STAND-OFFSTRUCTURAL

FASTENER

WALLPANELLAP

GIRT

PANEL TOSTRUCTURALAPPLICATION

PANEL TOPANEL

APPLICATION

PRE-DRILLING ISRECOMMENDED.

#17 STAND-OFFSHOULDER

58" +/-

NOTE: USE STANDARD 1 14" FASTENERS AT

CRIMPED BASE AND AROUND FRAMEDOPENINGS.

Page 8: Basic Panels & Accessories

1 2

DIRECTION TO ERECTPANEL RIB ROOF

SIDEWALL ONE

SIDEWALL TWOBUILDING LENGTH

FIELD CUT(IF REQ'D)

END WALLEND WALL

B.L. B.L.ROOF PLAN

A

B

C

FOR BUILDINGS HAVING ROOFEXTENSIONS, CANOPIES, LEAN-TO'S,ETC., WALL SHEETING SHOULD BEINSTALLED BEFORE ROOF SHEETS TOALLOW FOR WORKING CLEARANCES.

IMPORTANT NOTE:

BL

(A) & (C) denote panel rib roof sheets (B) denotes panel rib cap sheet.

Line (1) is location of the lap rib & line (2) represents the purlin bearing rib of panels (A) &(C) and cap sheet (B).

Locate the center of the lap rib exactly over B.L. Attach panels (A) & (C). Then attach capsheet (B).

Each side of the panel rib roof and the panel rib cap must be run in conjuction with eachother to insure correct alignment.

Refer to different sections of this manual for details relating to eave alignment of roof panels,mastic application, fastener types and spacing and building accessories located on the roof.

All damaged paint finishes are to be retouched to prevent rusting.

In the event a screw is installed in the wrong location or should a screw break during thedriving process, remove the screw and install one of a larger diameter to prevent a potentialleak. If removal of a screw remnant is not possible, water proofing measures are to be takento insure water tightness.

NOTES:

1.

2.

3.

4.

5.

6.

7.

PANEL RIB INSTALLATION / ROOF PANELSB-1

03/15/14

Page 9: Basic Panels & Accessories

Concentrated heavy loads (personnel or materials) occurring on the roof during constructionshall be distributed uniformly over a large area in such a manner as to prevent damage tobuilding components.

All metal shavings occurring as a result of drilling operations on the roof are to be removed insuch a manner as to prevent damage or staining of roof finish.

NOTES:

8.

9.

PANEL RIB INSTALLATION / ROOF PANELSB-2

10/01/09

Page 10: Basic Panels & Accessories

AS SPECIFIED

2"

OVERHANG

SELF-DRILLINGSTITCHFASTENER

MASTIC

ROOF SHEET

PURLINBEARINGEDGE

MASTICINSTALLEDON "WET"SIDE OF LAP

EAVE MEMBER

ROOF SHEET

EXTEND MASTIC DOWN PURLINBEARING EDGE AND RETURN TOWEB SIDE OF EAVE MEMBER

MASTIC

WETSIDE

LAP RIB DETAIL

REMOVING RELEASE PAPER

ROOF SHEET

PURLINBEARINGEDGE

MASTIC DETAIL AT EAVE PURLIN

SINGLE LAP CONDITION

IMPORTANT: REMOVERELEASE PAPER BYPULLING PAPER BACK ATAPPROXIMATELY 180°.

Clean area where mastic will be applied.

Install mastic on purlin bearing lap rib of roof(prior to installing next roof sheet), applypressure over entire area to obtain adhesion.

END LAP DETAILInstall mastic at end lapedges as shown (all roofsheet end laps)

PURLIN

LOWERROOFSHEET

UPPERROOFSHEET

TAPE MASTIC

4"1

2" 3 12"

INSTALLATION PROCEDURE / TAPE MASTICB-3

03/15/14

Page 11: Basic Panels & Accessories

FLOW

STEP ONEROOF SHEET END LAP CONDITION

INSTALL MASTIC ON "WET" SIDE OFSIDE-LAP AND EXTEND DOWN 6"OVER PREVIOUSLY INSTALLEDMASTIC.

ROOF PURLIN

PREVIOUSLYINSTALLEDMASTIC.

6" MASTICLAP

A

B

STEP TWO

ROOF SHEET END LAP CONDITION

Position roof sheet "A" lap rib over previously installed roofsheet purlin bearing edge. Use standard lap dimensions.

Start tape mastic approx. 6" up adjacent sheet overlappingpreviously installed mastic.

Install mastic across roof sheet and downpurlin bearing rib as shown.

Install mastic on "WET"side of purlin bearing edgeas shown.

Fasten roof sheet to purlinsother than purlin at end lapcondition. Refer to fastenerdetails for recommendedtypes and placement of rooffasteners.

Remove release paperbefore installing sheet "B".

Position sheet "B" overpreviously installed roofsheets. Used standard roofsheet lap dimensions.

Attach sheet "B" to purlinsper fastening details. Useonly recommended rooffasteners and install insequence as shown.

Install mastic as shown,lapping previously installedmastic approx. 6". Removerelease paper from mastic.

1.

2.

3.

4.

5.

6.

7.

8.

9.

MASTIC & SHEETING INSTALLATION / ROOF B-4

03/15/14

3"

6" LAP

FLOW

3"

PREVIOUSLYINSTALLED ROOFSHEET

TAPEMASTIC

PREVIOUSLYINSTALLEDMASTIC

ROOFPURLIN

A

Page 12: Basic Panels & Accessories

FLOW

FLOW

C

A

B

D

C

A

B

TAPE MASTIC INSTALLEDON "WET" SIDE OF LAPRIB.

INSTALL MASTICACROSS ROOFSHEET AND DOWNPURLIN BEARINGRIB AS SHOWN.

ROOF PURLIN

PREVIOUSLYINSTALLEDROOF SHEETS

6" LAP

3"

6" MASTIC LAP

PREVIOUSLYINSTALLEDMASTIC

PREVIOUSLYINSTALLEDROOFSHEETS

ROOFPURLIN

NOTE: MASTIC TOBE INSTALLED ON"WET" SIDE OF LAPRIB.

Position roof sheet "C" over previouslyinstalled roof sheets as shown. Maintainstandard lap dimension.

10. Fasten roof sheet to purlins other thanpurlin at end lap condition. Refer tofastener details for recommended fastenertypes and placement .

11.

Apply tape mastic to roof sheet "C"as shown lapping 6" over previouslyinstalled mastic.

12.

Apply tape mastic to roofsheet "D" as shown. Lapmastic over previouslyinstalled mastic, approx. 6".

14.

Mastic and sheet placement forfour-lap condition at end lapsshould now be watertight.Repeat steps 1 thru 4 forremaining roof sheets.

15.

Remove release paper and installsheet "D". Position over previouslyinstalled roof sheets and attach topurlins per fastener details.

13.

STEP THREE

STEP FOURROOF SHEET END LAP CONDITION

NOTE: MAINTAINSTANDARD ROOFSHEET/PURLIN LAPDIM.

MASTIC & SHEETING INSTALLATION / ROOF B-5

03/15/14

ROOF SHEET END LAPCONDITION

Page 13: Basic Panels & Accessories

3"

1"

MASTIC TO BE INSTALLEDAPPROX. 1" FROM EDGE OFCAP SHEET.

ROOF SHEET

PURLIN

MASTIC

PANEL RIBCAP SHEET

ROOF FASTENERS

SECTION THRU RIDGE

CAP SHEET INSTALLATION

PURLINS

ROOF SHEET

PANEL RIB CAPSHEET

MASTIC

ROOF SHEET (REFER TO FASTENERRECOMMENDATIONS)

NOTE: CAP SHEET TO BE USED ASAN ALIGNMENT GUIDE WHENSTARTING SHEETING ON OPPOSITESIDE OF RIDGE.

INSTALLATION PROCEDURES / CAP SHEETB-6

10/01/09

Page 14: Basic Panels & Accessories

FASTENER APPLICATION ON ROOFVP "STANDARD" ROOF CONSTRUCTION

(QUALIFIES AS UL CLASS 60 UPLIFT RATED ROOF)

ROOF STITCHFASTENER

1'-0" 1'-0" 1'-0"

STRUCTURALFASTENER

END LAP & RIDGE CAP

INTERMEDIATE PURLIN

BUILDING EAVE

STITCH FASTENER

STRUCTURALFASTENER

STRUCTURALFASTENER

PANEL SIDELAP

FASTENER SPACING AT ROOF PANELSSECTION THRU ROOF

STITCH FASTENER

STITCH FASTENER

FASTENER APPLCATION ON ROOF B-7

10/01/09

Page 15: Basic Panels & Accessories

FASTENER APPLICATION ON ROOF B-8

03/15/14

CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.

CENTERLINE PURLINFLANGE & ROOFSTRUCTURALFASTENERS.

NOTE: INSTALL ROOFSTRUCTURALFASTENERS FIRST. (INSEQUENCE ASSHOWN).

CENTERLINE ROOFSTRUCTURALFASTENERS.

CENTERLINE PURLINFLANGE & ROOFSTITCH FASTENERS.

TYPICAL AT INTERMEDIATE PURLINS

1 1/

2"

1

A 1

PURLIN

EAVEMEMBER

A

1

6 5 432

TYPICAL AT INTERMEDIATE PURLINS

C

STITCH FASTENER(TYPICAL)

1

C2 3

TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS

1 1/

2"

PURLIN

A

1"

NOTE: INSTALL ROOFSTITCH FASTENERS ATMID-POINTS BETWEENEACH INTERMEDIATEPURLIN.

4" PANEL LAP

3"435261

1

C

2"

B D

NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).

Page 16: Basic Panels & Accessories

FASTENER APPLICATION ON ROOF"ICE DAMMING"

STRUCTURALFASTENER

END LAP & RIDGE CAP

INTERMEDIATE PURLIN

BUILDING EAVE

STITCH FASTENER

STRUCTURALFASTENER

STRUCTURALFASTENER

PANEL SIDE LAP

FASTENER SPACING AT ROOF PANELS

SECTION THRU ROOF

STITCH FASTENER

STITCH FASTENER

20"

5'-0"5'-0"

1'-0"1'-0" 1'-0"

TYPICAL PURLIN SPACING

ROOF STITCHFASTENER

SIDE LAP FASTENER LOCATIONS:6" O.C. FOR FIRST 10'-0" THEN ATEACH PURLIN AND AT 20" CENTERSTO RIDGE.

FASTENER APPLICATION ON ROOFB-9

10/01/09

Page 17: Basic Panels & Accessories

2"

4" PANEL LAP

1"

3"

41 8 2 6 3 4

A

B

C

D

1 1/

2"

CENTERLINE ROOFSTRUCTURALFASTENERS.

PURLIN

TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS

NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).

NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).

NOTE: INSTALL (2) ROOFSTITCH FASTENERS (AT 20"O.C.) BETWEEN EACHINTERMEDIATE PURLIN.

11 2 3

A

1 2 3

A468

TYPICAL AT INTERMEDIATE PURLINS

2

PURLIN

CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.

CENTERLINE PURLINFLANGE & ROOFSTITCH FASTENERS.

1 1/

2"

CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.

STITCH FASTENER(TYPICAL)

EAVEMEMBER

C

C

1

6"9 7 5

1

3

2

5 7

869 7 5

1 1/

2"

3"5 1/

2"

TYPICAL AT EAVE MEMBER

FASTENER APPICATION ON ROOF B-10

03/15/14

Page 18: Basic Panels & Accessories

FASTENER APPLICATION ON ROOF"UL CLASS 90-UPLIFT RATED"

STRUCTURALFASTENER

END LAP & RIDGE CAP

INTERMEDIATE PURLIN

BUILDING EAVE

STITCHFASTENER

STRUCTURALFASTENER

STRUCTURALFASTENER

PANELSIDE LAP

FASTENER SPACING AT ROOF PANELS

SECTION THRU ROOF

STITCH FASTENER

STITCH FASTENER

20"

5'-0"5'-0"

1'-0"1'-0" 1'-0"

TYPICAL PURLIN SPACING

ROOF STITCHFASTENER

SIDE LAP FASTENER LOCATIONS:AT EACH PURLIN AND ATMID-POINTS BETWEEN PURLINS.

FASTENER APPLICATION ON ROOF B-11

10/01/09

Page 19: Basic Panels & Accessories

2"

4" PANEL LAP

1"

3"

11 8 2 6 3 4

A

B

C

D

1 1/

2"

CENTERLINEROOFSTRUCTURALFASTENERS.

TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS

NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).

NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).

NOTE: INSTALL ROOF STITCHFASTENERS AT MID-POINTSBETWEEN EACHINTERMEDIATE PURLIN.

11 2 3

A

1 2 3

A468

TYPICAL AT INTERMEDIATE PURLINS

1

PURLIN

CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.

CENTERLINEPURLIN FLANGE& ROOF STITCHFASTENERS.

1 1/

2"

CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.

EAVEMEMBER

C

C9 7 5

2 3 5

649 7 53"

5 46

STITCHFASTENER

TYPICAL AT EAVE MEMBERB-12

03/15/14

Page 20: Basic Panels & Accessories

FASTENER APPLICATION ON ROOF"UL CLASS 90-UPLIFT RATED & ICE DAMMING"

STRUCTURALFASTENER

END LAP & RIDGE CAP

INTERMEDIATE PURLIN

BUILDING EAVE

STITCH FASTENER

STRUCTURALFASTENER

STRUCTURALFASTENER

PANEL SIDE LAP

FASTENER SPACING AT ROOF PANELS

SECTION THRU ROOF

STITCH FASTENER

STITCH FASTENER

20"

5'-0"5'-0"

1'-0"1'-0" 1'-0"

TYPICAL PURLIN SPACING

ROOF STITCHFASTENER

SIDE LAP FASTENER LOCATIONS:6" O.C. FOR FIRST 10'-0" THEN ATEACH PURLIN AND AT 20" CENTERSTO RIDGE.

FASTENER APPLICATION ON ROOF B-13

10/01/09

Page 21: Basic Panels & Accessories

2"

4" PANEL LAP

1"

3"

41 8 2 6 3 4

A

B

C

D

1 1/

2"

CENTERLINE ROOFSTRUCTURALFASTENERS.

PURLIN

TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS

NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).

NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED (INSEQUENCE ASSHOWN).

NOTE: INSTALL (2) ROOF STITCHFASTENERS AT (AT 20" O.C.)BETWEEN EACH INTERMEDIATEPURLIN.

11 2 3

A

1 2 3

A468

TYPICAL AT INTERMEDIATE PURLINS

TYPICAL AT EAVE MEMBER

2

PURLIN

CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.

CENTERLINEPURLIN FLANGE& ROOF STITCHFASTENERS.

1 1/

2"

CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.

EAVEMEMBER

C

C9 7 5

3 5 7

869 7 53 "

5 46

1

6"

1

2

5 1/

2"

STITCH FASTENER(TYPICAL)

1 1/

2"

FASTENER APPLICATION ON ROOFB-14

03/15/14

Page 22: Basic Panels & Accessories

DIRECTION OF ERECTION

WALLSTITCHFASTENER

CAPILLARYBEAD

GIRT

SIDE LAP DETAIL

ROOF SHEETING

EAVE OR RAKE MEMBER.(EAVE STRUT MEMBERSHOWN)

GIRTS

WALL STRUCTURALFASTENER, 1 PER FOOTAT INT. GIRTS.

BASE MEMBER

WALL STITCH FASTENER, 1PER SUPPORT AND 1 PERGIRT SPACE, 2 FASTENERSREQUIRED WHEN SPACEEXCEEDS 6'-0".

WALL STRUCTURALFASTENER, 2 PERFOOT.

TEMPORARYBLOCKING MATERIAL(NBVP)

WALL STRUCTURALFASTENER, 2 PERFOOT.

PANEL SIDE LAP

SIDE WALL ELEVATION

Block girts to "LEVEL POSITION"before starting panel erection.Maintain blocking until panel tostructural fasteners are installed.

Align and plumb first wall panel withthe roof panel (making sure notchedtop of side wall panel fits ribs of firstroof panel).

Attach panel to secondary framing(see recommendations for fastenertype and spacing).

Proceed to install adjacent panel. Useonly a minimum number of fastenersto hold panels in place until chalklines can be popped, to assure astraight line run of fasteners.

Install side lap fasteners only after allstructural fasteners are in place.

NOTES:1.

2.

3.

4.

5.

PANEL RIB INSTALLATION / SIDE WALL PANELSB-15

03/15/14

NOTE: FOR INSULATION GREATERTHAN 4", USE #17/12-14 X 1 7

8"STAND-OFF STRUCTURAL FASTENERS.ALWAYS USE 12-14 X 1 1

4" AT CRIMPEDBASE AND AT FRAMED OPENINGS.

Page 23: Basic Panels & Accessories

ELEVATION

NOTE:1.

2.

3.

4.

Endwall panel marked "A" will be installed first, make sure panel isplumb and that the center of the panel rib is located at the exactcenter of the building ridge .

Attach panel "A". Do not fasten along the left hand edge of panel.The rib of all remaining panels to the left of panel "A" must beunderlapped.

Field cut panels at building line if required or back lap if acceptable.

As roof pitch increases, protective measures are to be taken toprevent personnel or materials from falling from building and resultingin bodily injury.

BL BL

CENTER LINEBUILDING AND PANEL RIB

TOP OF RAKE

FIELDCUT

FIELD CUTIF REQ'D.

BUILDING WIDTH

A

DIRECTION OF ERECTION(UNDER LAP PANEL RIB)

DIRECTION OF ERECTION(STANDARD LAP PROCEDURE)

PANEL RIB "LEFT TO RIGHT" INSTALLATION / ENDWALLSB-16

03/15/14

Page 24: Basic Panels & Accessories

ELEVATION

NOTE:1.

2.

3.

4.

Endwall panel marked "A" will be installed first. Make sure panel isplumb and that the center of the panel rib is located at the exactcenter of the building ridge.

Attach panel "A". Do not fasten along the right hand edge of panel.The panel rib of all remaining panels to the right of panel "A" MUSTBE UNDERLAPPED.

Field cut panels at building line if required or back lap if acceptable.

As roof pitch increases, protective measures are to be taken toprevent personnel or materials from falling from building and resultingin body injury.

BL BL

TOP OF RAKE

FIELDCUT

FIELD CUTIF REQ'D.

BUILDING WIDTH

A

DIRECTION OF ERECTION(UNDER LAP PANEL RIB)DIRECTION OF ERECTION

(STANDARD LAP PROCEDURE)

CENTER LINEBUILDING AND PANEL RIB

PANEL RIB "RIGHT TO LEFT" INSTALLATION / ENDWALLSB-17

03/15/14

Page 25: Basic Panels & Accessories

5

4

321

INSTALL TUF-LITE IN ROOFSHEETS IN SEQUENCE ASSHOWN.

PANEL RIBROOFSHEET

INSTALLATION SEQUENCE

DO NOT STEP, WALK ORPLACE HEAVY LOADS ONTUF-LITE PANELS.

IMPORTANT NOTE:

TUF-LITES SHALL BE INSTALLED AS ROOF IS SHEETED ANDPROTECTIVE MEASURES TAKEN TO INSURE AGAINST MATERIALSOR PERSONNEL FROM FALLING THROUGH TUF-LITE.

IMPORTANT:

SIDE LAP DETAIL

END LAP DETAIL

ROOF STITCH FASTENER ATEACH MAJOR RIB.

ROOF STRUCTURAL FASTENERAT MINOR RIB AS SHOWN(TYP. BOTH END LAPS)

TUF-LITE

ROOF SHEET

MASTIC:DOUBLE ROWREQUIRED AT LOWEREND LAP ONLY.SINGLE ROW ATUPPER END LAP. MASTIC

TUF-LITEROOF SHEET

ROOF STITCH FASTENERAT 20" O.C.

ROOF STRUCTURALFASTENER ATSTANDARD SPACINGAT INTERMEDIATEPURLINS

PANEL RIB TUF-LITESTANDARD INSTALLATION

ROOF STITCH FASTENER ATEACH MAJOR RIB.

ROOF STRUCTURAL FASTENERAT MINOR RIBS AS SHOWN(TYP. BOTH END LAPS).

PANEL RIB TUF-LITE STANDARD INSTALLATIONC-1

03/15/14

Page 26: Basic Panels & Accessories

PANEL RIB TUF-LITE STANDARD INSTALLATIONC-2

10/01/09

SECTION THROUGH TUF-LITE

TUF-LITE SIDE LAP DETAIL

PURLIN SPACE

PURLIN SPACE

1"

1"

1" 3"

3"1"

OPTIONALCONDENSATION PAN

INSULATION

ROOFSHEET

MASTIC

ROOF STITCHFASTENERS@20" O.C.MASTIC

ROOFSHEET

INSULATION TUF-LITETRIM

ROOF STITCHFASTENERS@20" O.C.

TUF-LITE END LAPDIMENSION TO BE THE SAMEAS STANDARD ROOF SHEETEND LAP DIMENSIONS (4")(TYP. BOTH ENDS).

USE INSULATION OR INSIDECLOSURE AS ISOLATIONSPACER.

OPTIONALCONDENSATIONPAN

MASTIC

ROOF SHEET

ROOF STRUCTURALFASTENERS 3 PER FOOT

INSTALL ROOF STRUCTURAL ATSTANDARD SPACING ATINTERMEDIATE PURLINS.

ROOF STRUCTURALFASTENERS 3 PERFOOT

PURLIN

ROOFSHEET

TUF-LITETRIM

Page 27: Basic Panels & Accessories

5

4

321

INSTALL TUF-LITE IN ROOF SHEETSIN SEQUENCE AS SHOWN.

PANEL RIBROOF SHEET

INSTALLATION SEQUENCE

DO NOT STEP, WALK, ORPLACE HEAVY LOADS ONTUF-LITE PANELS.

IMPORTANT NOTE:

TUF-LITES SHALL BE INSTALLED AS ROOF IS SHEETED ANDPROTECTIVE MEASURES TAKEN TO INSURE AGAINST MATERIALSOR PERSONNEL FROM FALLING THROUGH TUF-LITE.

IMPORTANT:

SIDE LAP DETAIL

END LAP DETAIL

14"-14 X 1 18"

ROOF STITCH FASTENERw/ 7 8" WASHER AT EACHMAJOR RIB.

ROOF STRUCTURAL FASTENER W/ 78"

WASHER AT MINOR RIB AS SHOWN (TYP.BOTH END LAPS)

TUF-LITE

ROOFSHEET

MASTIC:DOUBLE ROWREQUIRED ATLOWER END LAPONLY. SINGLE ROWAT UPPER END LAP. MASTIC

TUF-LITEROOF SHEET

14"-14 X 1 18"ROOF

STITCH FASTENER W/ 78"

WASHER AT 10" O.C.

ROOF STRUCTURALFASTENER W/ 7

8"WASHER AT STANDARDSPACING ATINTERMEDIATE PURLINS.

PANEL RIB TUF-LITE INSTALLATIONU.L. CLASS 90 UPLIFT

ROOF STITCH FASTENER AT EACHMAJOR RIB.

ROOF STRUCTURAL FASTENERAT MINOR RIBS AS SHOWN(TYP. BOTH END LAPS).

PANEL RIB TUF-LITE INSTALLATION U.L. CLASS 90 UPLIFTC-3

03/15/14

Page 28: Basic Panels & Accessories

SECTION THROUGH TUF-LITE

TUF-LITE SIDE LAP DETAIL

PURLIN SPACE

PURLIN SPACE

1"

1"

1" 3"

3"1"

OPTIONALCONDENSATION PAN

INSULATION

ROOFSHEET

MASTICMASTIC

ROOFSHEET

INSULATIONTUF-LITE TRIM

14"-14 X 1 18"

ROOF STITCHFASTENERS W/ 7

8"WASHERS @ 20" O.C.

TUF-LITE END LAP DIMENSION TO BETHE SAME AS STANDARD ROOF SHEETEND LAP DIMENSIONS (4") (TYP. BOTHENDS).

USE INSULATION ORINSIDE CLOSURE ASISOLATION SPACER.

OPTIONAL CONDENSATIONPAN

MASTIC

ROOF SHEET

ROOF STRUCTURALFASTENERS 3 PER FOOTROOF STRUCTURAL

FASTENERS 3 PERFOOT

PURLIN

ROOFSHEET

TUF-LITETRIM

14"-14 X 1 18"

ROOF STITCHFASTENERS W/ 7

8"WASHERS @ 20" O.C.

ROOF STRUCTURALFASTENERS 3 PER FOOT

PANEL RIB TUF-LITE INSTALLATION U.L. CLASS 90 UPLIFTC-4

03/15/14

Page 29: Basic Panels & Accessories

WALL BASE DETAIL

A

B

A

A

D

A

C

BASE ANGLE

ATTACH TOBASE ANGLE

INSULATION

FLOORELEVATION

FOLD INSULATIONFACING BACK TOPREVENT "WICKING"ACTION OF EXPOSEDINSULATION.

INSULATION SIDE LAP DETAIL(OPTIONAL)

6"TAB

INSULATION SIDE TAB DETAIL(ROOF AND WALL APPLICATIONS)

DOUBLEFOLDTABS

3" TABEACH SIDE

INSULATION FACING

STARTING ROOF INSULATION

BUILDING LINE

RAKE ANGLEEND WALLINSULATION

DOUBLEFOLDTABS

INSTALLATIONDIRECTION

INSULATIONFACING

ROOFINSULATIONSTARTERSTRIP

INSULATION METHOD #1

INSULATION METHOD #2

NARROW BUILDING

WIDE BUILDING

ATTACH (D) TO PURLIN,LAP (C) OVER (D) ANDGLUE, MAKE SURE (D)DOES NOT EXTEND PASTTOP FLANGE OF PURLIN.

STAPLE 18" O.C.MAXIMUM

BUILDING ACCESSORIES / INSULATIONC-5

03/15/14

Page 30: Basic Panels & Accessories

CD

ROOFINSULATION

EAVE STRUT

EAVE DETAIL

INSULATION LAP DETAILPURLIN

ROOFINSULATION

ATTACH (D) TO PURLIN,LAP (C) OVER (D) ANDGLUE, MAKE SURE (D)DOES NOT EXTEND PASTTOP FLANGE OF PURLIN.

Wall insulation (A) is shipped in maximum roll lengths and is to be field cut to exactlengths before installing. Wall insulation should extend from top of eave member to 1"below floor elevation. Do not cut long and trim at bottom of wall panels. Glue at eavemember and base angle, pull facing tight and hold in place until wall panel is attached(See Wall Base Detail).

Roof insulation (B) is shipped as one roll for each length or for two or more lengths to befield cut from a single roll, depending on building width. Pull insulation simultaneouslyfrom each side of the building until facing is snug. Allow insulation to expand to it's fullthickness. Fold insulation facing back to prevent " WICKING" action of exposedinsulation, similar to wall base detail. Glue to top of eave member and trim excessinsulation.

Roof insulation (C) and (D) are shipped as one roll for each length. Install in a similarmanner to insulation (B). Use same procedure for end walls as for side walls.

FOLD INSULATIONFACING BACK TOPREVENT"WICKING" ACTIONOF EXPOSEDINSULATION.

GENERAL NOTES:

1.

2.

3.

BUILDING ACCESSORIES / INSULATIONC-6

03/15/14

Page 31: Basic Panels & Accessories

SECTION @ CANOPYASSEMBLY

Mount attaching angle at 7'-6"above floor. Locate over doorand attach w/ (2) BOLTS-1

2" X3" AND (3) NUTS as shown.

Locate wall structural anglesbetween girts. Field drill 9

16"hole top and bottom into girtsand bolt into place.

Drill (2) holes through wallsheet at 29" - 34" above top ofcanopy as shown and installhangar rods w/ (2) NUTS.

Bolt canopy to attaching angleand hangar rods as shown.

STEP 4

STEP 3

STEP 2

STEP 1

3070 DOORCANOPY

6070 DOORCANOPY

ATTACHINGANGLE

CANOPY

2'-0" 2'-0"

HANGARRODS

CANOPY

ATTACHINGANGLE

HANGARRODS

1'-3" 1'-3"

C.L.DOOR

C.L.DOOR

WALLSHEETING

HEADTRIM

DOORFRAME

12" X 3" BOLT

W/ (3) NUTS

DRILL FASCIA AND ATTACH SCOUP TO DRAINAWAY FROM DOOR OPENING.

NOTE:

7'-6

"

7'-6

"PREASSEMBLEDCANOPY

DOORFRAMEASSEMBLY

ADJUSTINGNUT ANDWASHERS

HANGAR ROD

APPLY SILICONE SEALANTWHERE ROD PENETRATESWALL SHEETING

GIRT

7'-6

"G

IRT

SPAC

ING

29"

TO1

2" X 11/2" A325BOLT ANDNUT (TYP.)

WALLSHEETING

WALLSTRUCTURALANGLES

34"

SERVICE DOOR CANOPY INSTALLATIONC-7

03/15/14

34"

Page 32: Basic Panels & Accessories

SECTION "F"

BL

DETAIL "A"

DETAIL "C"

DETAIL "D"

DETAIL "E"

SECTION "B"

AT MINOR RIB AT MAJOR RIB

HEADERTRIM

WALLPANEL

DOORFLASHING

WALLSTRUCTURALFASTENER

HEADER

DOORFLASHING JAMB

WALLPANEL

JAMB TRIM(FIELDBEND)

WALLSTRUCTURALFASTENER

WALLSTRUCTURALFASTENER

JAMB TRIM

WALLSTRUCTURALFASTENER

DOORFLASHING

JAMBWALL PANEL

GIRT

"A"

HEADER

JAMB

BASEMEMBER

"B"

"F"

"E"

"D"

GIRT "C"SINGLE JAMB

CEE GIRT SIMILARZEE GIRT SHOWN

GIRT CLIP

(2) 1/2" A307 THINHEAD BOLT & NUT

6"MAX

CONCRETE FSNRAT 24" O.C.

(BY BUILDER)BASE MEMBER

JAMB BASECLIP

1/2" ANCHORRODS WTH

JAMB, SINGLEOR DOUBLE

HARDENED WASHER

(2) 1/2" A307 THINHEAD BOLT & NUT

DOOR HEADER

SINGLE JAMB

HEADER TO JAMB CLIP

(2) 1/2" A307 THINHEAD BOLT & NUT

JAMB,SINGLE ORDOUBLE

ZEE GIRT

(2) 1/2" A307 THINHEAD BOLT & NUT

(JAMB SUPPORTGIRT)

BL

ACCESSORIES / OVERHEAD DOOR OPENINGC-8

03/15/14

Page 33: Basic Panels & Accessories

MULLIONRIGHTJAMB

LEFTJAMB

SILL ATBASE ANGLE

HEAD & SILLAT GIRT

HEAD & SILL AT STACK

3030 FIXED LOUVERAND

SECTION ATLOUVER

GENERAL PROCEDURES

INSECTSCREEN

3'-0"LOUVER DIM.

3'-0

"LO

UVE

R D

IM.

VP-205 RIVET(TYP.)

JAMB FINSET IN SEALANT

SILLOUTSIDECLOSURE

HEAD GUTTER TROUGH SETIN SEALANT

CUT

SHEE

T O

PEN

ING

=LO

UVE

R D

IM.

VP-205 RIVETS(TYP.)

PANEL RIB

OUTSIDECLOSURE

2 12"

4 12"

12"

1 12"

LOU

VER

DIM

.LO

UVE

R D

IM.

LOU

VER

DIM

.

LOUVER DIM.LOUVER DIM.

PANEL RIB

VP-205RIVET(TYP.)

SHEETMODULE

SHEETMODULE

SHEETMODULE

SHEETMODULELOUVER DIM. MINUS 2 38"

CUT SHEET OPENING=

WINDOW SUPPORTCHANNEL

1 316"1 316"

Installation procedures shown are for louversinstalled on the 3'-0" panel rib module.

1.

Mulling of louvers requires the use of awindow support channel at each mullion.

Stacking of louvers requires the relocation ofscreen clips where the sill overlaps the headgutter.

2.

3.

3030 OPERABLE LOUVER

BUILDING ACCESSORIES / VP LOUVERSC-9

03/15/14

Page 34: Basic Panels & Accessories

DIRECTION OF

INSTALLATION

SCREENDETAIL

ASSEMBLED VIEW

CUT-OUT VIEW

INSECT SCREENFRAME

VP-205RIVET

ATTACH SCREEN W/CLIPS INTOPRE-LOCATED HOLES

RELOCATESCREEN CLIPAT STACKEDLOUVERS

VP-205 RIVET

STACKEDHEAD &SILL

INSECTSCREEN

STANDARD WALLFASTENERS EACHSIDE OF RIB OVERLOUVER

STANDARDWALL FASTENERARRANGEMENT

ATTACHLOUVER WITH(6) VP-205RIVETS

PANELRIB

3

2

4

1

1

2

3

4

SHEET 2UNDERLAPSSHEET 1

PANELRIB

LOUVER DIM.MINUS 2 38"

LOU

VER

DIM

.SHEET 3OVERLAPSSHEET 2

Install wall sheet 1 in sequence shown. Installinsulation as noted in general procedures ifrequired.

Install sheet 2 by underlapping sheet 1.

Install sheet 3 in the normal manner.

Cut opening in insulation.

Install louver over sheet 3 with jamb fins placedto ovelap ribs of adjacent sheets 1 & 3. (DONOT UNDERLAP LOUVER JAMBS.) SetJambs in sealant.

Install sheet 4 above louver. Lap sheet 4 overjamb fins at louver head and into bottom ofhead gutter trough. Sheet 4 to be installed withlap ribs overlapping the side ribs of sheets 1and 3. Set head in sealant.

Attach louver with (6) VP-205 Rivets. (2) Rivetseach jamb and 2 Rivets at sill. Completeattachment of wall sheets to girts and side lapswith standard wall fasteners.

Attach insect screen to outside of louver usingclips provided. Locate dogging clip for operablelouver as require and fasten with standard wallfasteners.

STEP 1

STEP 2

STEP 3

STEP 4

STEP 5

STEP 6

STEP 7

STEP 8

INSTALLATION PROCEDURE / VP LOUVERC-10

03/15/14

Page 35: Basic Panels & Accessories

SECTION

APEX 20 VENTILATOR

PANEL RIBROOFPANEL

POP RIVETVENTILATOR TOSLEEVE

WINDBAND

DAMPERCAP

SCREEN

AIRSHAFT

PURLIN

1" DIA. PULLEY

DAMPERCHORD

TAPE MASTIC BOTHSIDES OF CLOSURE

ROOF STRUCTURALFASTENER (3) PERFOOT AT ENDLAPS

NOTE: DETAILED INSTALLATION INSTRUCTIONS AREPACKAGED WITH EACH VENTILATOR.

ROOFSTITCH FSNR 6" O.C.

OUTSIDE CLOSURE(80140) WITHTAPE MASTICBOTH SIDES OF

ROOF STITCH FSNR1 PER HIGH RIB

TAPE MASTIC

INSULATIONRETAINER

PANEL RIBAPEX 20VENT BASE

20" DIA. VENT

CLOSURE

ONLY CUT THE HOLE IN THERIDGE PANEL LARGE ENOUGHTO ALLOW FOR THE FLANGEON THE UNDERSIDE OF THE VENT BASE

BUILDING ACCESSORIES / APEX 20 VENTILATORC-11

03/15/14

REFER TO SED'S FOR MASTICAND FASTENER TYPE.

Page 36: Basic Panels & Accessories

SECTION

10'-0" RIDGE VENTILATOR

DIRECTION OF ERECTION

ROOF STITCHFASTENER AT EACHMAJOR RIB

CUT AT THIS SIDEOF MAJOR RIB

Locate vent so that the end sectionof vent is resting on the purlinbearing edge of panel rib cap.

Field cut panel rib cap to make a 2'-0"wide cap, center to center of ribs, andleaving a purlin bearing rib at eachside .

1.

2.

By deleting end panels at connection,10'-0" sections of ventilators may bejoined together to make a continuousrun. A continuous run should neverstart or end at building line.

3.

PANEL RIBRIDGE VENT DAMPER

TAPE MASTIC BOTHSIDES OF CLOSURE

ROOF STITCHFASTENER(12" O.C.)

OUTSIDE CLOSURE REFER TO SED'sPROVIDED WITHJOB DRAWINGS.

ACCESSORIES / 10'-0" RIDGE VENTILATORC-12

03/15/14

Page 37: Basic Panels & Accessories

BL

BASEGIRT

PARTIAL HEIGHTLINER

INSTALLATION DETAILS / PARTIAL AND FULL HEIGHT LINERC-13

03/15/14

FULL HEIGHT LINER@ SIDEWALL

EAVESTRUT

FULL HEIGHTLINER @ RAKE

Liner attaches to face of girts w/wallstructural fasteners at 12" o.c.Field cut liner panel, if required, tofollow slope of rake beam.

NOTES:1.

2.

TRIM ANGLE(ATTACH W/ S.D.FASTENERS 12" O.C.)

RAKEBEAM

ALL LINER @ BASE

GIRT

GIRT

CAP TRIM -ATTACH WITHSTITCH SCREWS12" O.C.

CAP TRIM -ATTACH WITHSTITCH SCREWS12" O.C.

CAP TRIM -ATTACH WITHSTITCHSCREWS @ 12"O.C.

Page 38: Basic Panels & Accessories

DETAIL ATJAMB

BL

BL

DETAIL ATHEADER

LINER DETAILAT WINDOW

DETAIL AT SILL

LINER

FLOORLINE

BASEGIRT

WINDOWLOCATION

"C"

WALL STITCH.FASTENER

LINER PANEL

SILL

SILL FLASHING

WALLPANEL

WINDOW

WALL PANEL

JAMB

LINER PANELJAMB TRIM

WALL STRUCT.FASTENER

JAMBFLASHING

WINDOW

HEADFLASHING

HEADER

JAMB

WINDOW

LINERPANELGIRT

WALLPANEL

WINDOW OPENING SIZESLiner attaches to face of girts w/wallstructural fasteners @ 12" o.c.

NOTES:1.

2060 72" 12" 21 1/4"

3030

3040

6030

6040

36"

48"

36"

48"

48"

36"

48"

36"

33 1/4"

33 1/4"

69 1/4"

69 1/4"

WINDOW SIZE

DIM."A"

DIM."B"

DIM."C"

DIM. A & C ARE INSIDE CLEARFRAMING DIMENSIONS. (DIM. B ISFROM FLOOR LINE TO TOP OF SILL).

*

"A"

"B"

WALLSTITCHFASTENER

INSTALLATION DETAILS C-14

03/15/14

Page 39: Basic Panels & Accessories

DETAIL AT HEADER

BL

BL

DETAIL AT JAMB

LINER ATOVERHEAD DOOR

DOORFLASHING

JAMBTRIM

LINERPANEL

DOORJAMB

JAMBTRIM

WALLPANEL

DOORHEADER

DOORFLASHING

LINER HEAD TRIM

LINERPANEL

WALLPANEL

HEADTRIM

WALLSTRUCT.FASTENER12" O.C.

DOORFLASHING

HEAD TRIM

WALLPANEL

LINERPANEL

WALL STRUCT.FASTENER 12" O.C.

LINER HEAD TRIM

WALL STRUCT.FASTENERDOOR

HEADER

DOOR FLASHING

Liner attaches to inside faceof girts w/wall structuralfasteners.

All overhead door flashing &trim attaches to framingw/wall structural fasteners12" O.C.

1.

2.

NOTES:

OVERHEAD DOOR DETAILS / LINER PANELC-15

03/15/14

JAMB TRIM

Page 40: Basic Panels & Accessories

SERVICE DOORFULL HEIGHT LINER

BL

7'-6"GIRT

BL

BL

BL

7'-6"GIRT

DETAIL AT JAMB

SERVICE DOORPARTIAL HEIGHT LINER

DETAIL AT HEADER

DETAIL AT JAMB

DETAIL AT HEADER

7'-6"GIRT

7'-6"GIRT

DOORFRAME

LINERPANEL

FLOORLINE

DOORFRAME

LINERPANEL

FLOORLINE

LINERPANEL

WALL STITCHFASTENER

DOOR LINERTRIM

WALL STRUCT.FASTENER

DOORFRAME

HEADTRIM

WALLPANEL

WALLPANEL

DOORFRAME

WALLSTRUCT.FASTENERS

DOOR LINERTRIM

LINERPANEL

LINERANGLE

LINERANGLE

WALL PANEL

LINERPANEL

DOOR LINERTRIM

DOORFRAME

WALLSTRUCT.FASTENERS

DOORFRAME

WALLPANEL

HEADTRIM

WALL STRUCT.FASTENER

DOOR LINERTRIM

WALL STITCHFASTENER

LINERPANEL

LINER TRIM

LINER DETAILS AT WALK DOORSC-16

03/15/14

Page 41: Basic Panels & Accessories

CLOSURE DETAIL @ EAVESECTION @ GIRT

CLOSURES

TYPICAL SECTION @CLOSURE

CLOSURE DETAIL @PURLINS

CLOSURE DETAIL @RIDGE PURLINS

EAVESTRUT

CLOSURE

BASEMEMBER

CONCRETE

LINER SHEET

GIRT

LAP AS REQ'D ANDATTACH W/ (4) POPRIVETS

CLOSURE (TYP.)

ATTACH TO GIRTW/ WALL STRUCT.FASTENERS (2) PERCLOSURE

ROOF SHEET

EAVE STRUT

ATTACH TO FLOORW/ RAMSET OROTHER APPROVEDMETHODS OFFASTENING.

7'-6

"5'

-0"

GIR

TPE

R B

LDG

.SP

ACES

REQ

UIR

EMEN

T

PURLIN

PURLINCLOSURES

FIELD CUT ANDLAP AT RIDGE.ATTACH WITH(2) POP RIVETS

WALL STRUCT.FASTENERS

WALL STRUCT.FASTENERS

LAP AS REQ'DAND ATTACH W/(4) POP RIVETSPURLIN

CLOSURE

PURLINSPACING

PURLINROOFSHEET

CLOSURE

TRIM

PARTITIONSHEET

WALL SHEET

VP PURLIN & GIRT CLOSURES / INSTALLATIONC-17

03/15/14

Page 42: Basic Panels & Accessories

RAKE FASCIA EAVE CLOSURE ASSEMBLY(WITH EAVE GUTTER)

45

SPREAD BIRD STOPFROM RAKE FASCIATO SLIDE ROOFSHEET IN-BETWEEN.

TAPE MASTIC

SLIDE RAKE FASCIAUP ROOF SHEET UNTILCLOSURE ASSEMBLYBUMPS CORNER TRIM.

CORNERTRIM

ROOFSHEET

RAKE FASCIA EAVE CLOSURE ASSEMBLY(WITHOUT EAVE GUTTER)

SIDE WALLSHEET

ATTACH RAKE FASCIA (WITH EAVE CLOSUREASSEMBLY) TO ROOF WITH ROOFFASTENERS AS SHOWN IN ERECTIONDETAILS SUPPLIED WITH JOB DRAWINGS.

INSTALL CORNER CAPWITH (6) POP RIVETS.

INSTALL PANEL RIB FILLERWITH POP RIVETS WHILEON THE GROUND.

(5)

(3)

CUT AWAY SHADEDAREA AS SHOWN.

POSITION GUTTER ON BUILDING WITH ENDFLUSH WITH OUTER EDGE OF CORNER.

(2)GUTTER

GUTTER ENDCLOSURE

BIRD STOP 2 1 2"

POSITION RAKE FASCIA ON BUILDING.SLIDE DOWN ROOF UNTIL END BUMPSGUTTER LIP. ATTACH FASCIA TOBUILDING WITH ROOF FASTENERS ASSHOWN.

(4)

ROOF FASTENERS TO BEINSTALLED PER ERECTIONDETAILS SUPPLIED WITH JOBDRAWINGS.

INSTALL GUTTER ENDCLOSURE (REF. GUTTERASSEMBLY & SEALANTPROCEDURES) THENINSTALL BIRD STOPWITH POP RIVETS ASSHOWN.

(1)

1"

ROOF FASTENER

EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-1

10/01/09

Page 43: Basic Panels & Accessories

FASCIA SPLICE

INSTALL FASCIA

WALL PANEL

OUTSIDE CLOSURE

TAPE MASTIC

ROOF PANEL

RAKEFASCIA

BRONZESKINNINGSEALANTBELOW

ROOFFASTENER

18" DIA. BLIND

RIVET (5) PERSPLICE 3" LAP

RAKEFASCIA

ROOFSTRUCTURALFASTENER

TAPE MASTIC

OUTSIDECLOSURE

WALL STITCHFASTENER

SEE ERECTION DRAWINGDETAILS FOR FASTENERTYPE AND SPACING.

EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-2

03/15/14

Page 44: Basic Panels & Accessories

EAVE FASCIA

BLBL

CORNER TRIM

FIELD CUT TOPOF TRIM ONLY(AS REQ'D.)

WALL PANEL

ATTACHWITH WALLSTITCHFASTENERSAT 12" O.C.

START AT BOTTOM OF WALL PANELAND WORK UP WITH UPPER PIECESLAPPING OVER LOWER ONES FORWATER SHED.

CORNER TRIM

EAVEFASCIA

LAP MINIMUM OF 3"AT SPLICE POINTS.(3) POP RIVETSREQ'D. PER SPLICE.

OUTSIDECLOSURE

ROOFPANEL

INSIDE CLOSUREWITH TAPE MASTICBOTH SIDES OFCLOSURE.

ROOF STITCHFASTENERS AT 12"O.C. (MINOR RIBSONLY)

EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-3

03/15/14

Page 45: Basic Panels & Accessories

SHEET METAL PEAK CAPWITH RAKE FASCIA RIB CAP

PLASTIC PEAK CAP

DETAILS SHOWN ARE FOR PANEL RIB ROOF ONLY

APPLY TAPE MASTICUNDER PEAK CAP

PEAK CAP TO LAP RAKEFASCIA A MINIMUM OF3" AND ATTACHED WITH(10) POP RIVETS TOPAND FRONT

PLASTIC PEAK CAP(PPC__)INSTALLEDOVER RAKE FASCIA

RAKE FASCIA

APPLY TAPE MASTICUNDER RIB CAP.

RAKE FASCIA

POP RIVETS

SHEET METALPEAK CAP(SPC__)

APPLY TAPEMASTIC UNDERRIB CAP.

PEAK RIB CAP (PRC)INSTALLED OVER PEAK CAPAND RAKE FASCIA ASSHOWN.

EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-4

07/28/15

Page 46: Basic Panels & Accessories

FIG. C: SEALANT APPLICATION

FIG. B: ASSEMBLY

FIG. A: FIELD TRIM LOCATIONS

GUTTER ENDCLOSURE

1"10

9

8

13

2

45

6

7

GUTTER ENDCLOSURE

14" BEAD

SEALANT

Place gutter end closure inposition as shown in FIG. B andcheck for proper nesting.

Trim as required 116" to 18" atlocations shown in FIG. A toinsure proper nesting.

Locate gutter end closure inplace 1" from gutter end asshown in FIG. B.

1.

2.

3.

PROCEDURE:

Secure gutter end closure inplace with standard 18" poprivats. IMPORTANT: Fasten insequence as shown in FIG. B.

4.

Apply 1 4" fillet bead ofrecommended gun gradesealeat inside gutter at jointconnection. FIG. C.

5.

GUTTER ASSEMBLY & SEALANT PROCEDURESD-5

12/14/12

Page 47: Basic Panels & Accessories

DOWNSPOUT LOCATIONFIG. B

160' MAX.

160' MAX.

987

13

2

54

6FIELD TRIM

GUTTER

1 1/2"

DOWNSPOUT LOCATIONFIG. A

EXPANSION JOINT(FOR BUILDINGS OVER 160' IN LENGTH)

GUTTER SPLICE ASSEMBLY

FIELD FABRICATECOVER FOR USEOVER GUTTERGAP

GUTTER ENDCAPS

GUTTERSTRAP

34" GAP

34" PLUS

END CAPDIM'S.

5"

4"

14"

SEALANT

18" BLIND RIVET

SEALANT

DOWNSPOUTNIPPLE. SETNIPPLE INSEALANT.ATTACH TOGUTTER WITH(8) 18" BLINDRIVETS.

APPLY LIBERALAMOUNT OFSEALANT OVERALL BLINDRIVETS (INSIDEGUTTER)

CUT MATERIAL FROM GUTTER PAN AT DIMENSIONSSHOWN IN FIG. A.

INSTALL NIPPLE AS SHOWN IN DETAIL BELOW.

1.

2.

NIPPLE INSTALLATION:

PROCEDURE: GUTTER ASSEMBLY

Field trim back flange of outsidegutter section as shown in FIG.B. "GUTTER SPLICEASSEMBLY"

Apply 1 4" bead of recommendedgun grade sealant 1" from gutteredge as shown in FIG. B.

Place gutter sections togetherwith 1 12" Lap.

Secure gutter sections togetherstandard 1 8" blind rivents.IMPORTANT: FASTEN INSEQUENCE AS SHOWN INFIG. B.

1.

2.

3.

4.

18" BLIND RIVET

GUTTER ASSEMBLY & SEALANT PROCEDURESD-6

03/15/14

Page 48: Basic Panels & Accessories

Panel closure angle, outsideclosures, inside closures and tapemastic must be in place before eavegutter can be installed.Gutter strap must have tape masticapplied to bottom side beforeinstallation.Install gutter strap with one roofstructural fastener into eave strut.Hang gutter, position, then attach toroof panel.Attach straps to gutter and roofpanel edges.

1.

2.

3.

4.

SECTION AT EAVE

SECTION THRU GUTTER STRAP

5.

APPLY TAPE MASTICTO BOTH SIDES OFCLOSURE. TAPE MASTIC

GUTTER STRAP

ROOF PANEL

ROOF STRUCTURALFASTENER (1 PERSTRAP)

ROOFSTRUCTURALFASTENER

GUTTER STRAP3'-0" O.C.

ROOF STITCHFASTENER 12" O.C.

INSIDECLOSURE

SIDEWALLSTITCHFASTENER12" O.C.

PANELCLOSUREANGLE

OUTSIDECLOSURE

EAVESTRUT

ROOF STITCHFASTENER (2PER STRAP)

EAVEGUTTER GUTTER

STRAP

TAPE MASTICON TOP OFGUTTER STRAP

PANELCLOSUREANGLE

INSIDECLOSURE

TAPEMASTIC

GUTTERSTRAP

EAVEGUTTER

SEE ERECTIONDETAILS FOROVERHANG DIM'S.

GUTTER INSTALLATIOND-7

03/15/14

Page 49: Basic Panels & Accessories

DOWNSPOUT INSTALLATIOND-8

03/15/14

Page 50: Basic Panels & Accessories

MULTI/VALLEY GUTTER

END CLOSURE

BUILDING TRIM INSTALLATION / VALLEY-GUTTER

GUTTER ASSEMBLY

PURLINDOWNSPOUT (NBVP)

INSIDECLOSURE

PANEL RIBROOF SHEET

ROOF STRUCTURAL FASTENERS(TYPICAL AS SHOWN)

NIPPLE (NBVP)

NOTE:REFER TO ERECTIONDETAILS SUPPLIED WITHJOB DRAWINGS FORROOF SHEET OVERHANG.

(VALLEY GUTTER SHOWN, MULTI GUTTER SIMILAR)

-Details shown are VP BUILDINGS standards. Builder can specify tapered rigid board in lieu of drain wedges (RIGID BOARD NOT BY VP BUILDINGS)

-Do not walk or stand in gutter.

for installatiuon procedures. BUILDINGS. Refer to manufacturers instructions-Liners, rigid board and adhesives are NOT BY VP

are NOT BY VP BUILDINGS.-Install scuppers as required by local code. Scuppers

the installation of the roof sheets.-Interior gutters and liners to be installed prior to

-Downspouts and downspout nipples are NOT PROVIDED BY VARCO PRUDEN. Welding of nipples to galvanized gutter is not recommended.

galvanizing (N.B.V.P.). interior gutters should be touched up with cold -Scratches and abrasions to the galvanized finish of the

-Interior gutters are to be installed level.

BUILDING TRIM INSTALLATION / INTERIOR GUTTER D-9

03/15/14

Page 51: Basic Panels & Accessories

INSIDE CLOSURE WITHCONTINUOUS TAPEMASTIC ON BOTH SIDES.

STRUCTURAL ROOFFASTENER AT EACHMINOR RIB (3/FOOT)

LINER (NBVP)

(GDW-)DRAIN WEDGE

VALLEY GUTTEROR MULTI GUTTER

BOARD (NBVP)1/2" RIGID

BUILDING TRIM INSTALLATION / MULTI-GUTTERD-10

03/15/14

Page 52: Basic Panels & Accessories

WP

ROOF STITCH FASTENER 6"O.C. FOR FIRST 10' FROMEAVE.

ROOFSTRUCTURALFASTENER (3)PER FOOT.

TAPE MASTIC

3" PIECE OF TAPEMASTIC

ROOF STRUCTURALFASTENER (3 PER FOOT)

316" BEAD OF NON-SKINNING

TUBE SEALANT FOR FIRST 10'FROM EAVE.

MASTIC DETAILS

OPTIONAL PLUG ATTACHMENT

1 2"

1'-0"O.C.

1'-0"O.C.

WIDE TAPEMASTIC OVERCLOSURE PLUG

(2) LAYERSWIDE TAPEMASTIC Refer to SED's for tape mastic sizes per location.

Apply (1) rows wide tape mastic 1/2" upslope fromwork point.Install closure plug to align with panel rib majorribs.Cut (1) 5" long piece of wide tape mastic and placeover top of plug.After installing sidelap mastic, install a 3" pigtail oftape mastic from top of the rib down to mastic.Apply 316" bead of non-skinning sealant to the wetside of the sidelap (UNDER THE ANTI-CAPILLARYBEAD) for the frist 10' from the eave.Install next panel and fasten sidelap with roof stitchfastener at 6" O.C. for frist 10' from the eave.Fasten eave end of panels with roof structuralfastener in minor ribs (3 PER FOOT).Use miter cut closure plugs at the valley conditionbetween intersecting buildings. Install mastic asdescribed above. Install fasteners in flat of panel atmaximum 3" O.C.

INSTRUCTIONS

1.

2.

3.

4.

5.

6.

7.

8.

HARD RUBBER CLOSURE PLUG AT VALLEYSD-11

03/15/14

PANEL RIBHARD RUBBERCLOSURE PLUG

Page 53: Basic Panels & Accessories

MULTI-GUTTERDETAIL AT RAKE FASCIA EAVE GUTTER

CONT. RIDGE VENT

LEAN-TO

EAVE SOFFIT

EAVE FASCIA

INSIDE CLOSURE OUTSIDE CLOSURE

EAVEGUTTER

PANEL RIBWALL

PANELRIB

OUTSIDECLOSURE

INSIDE CLOSURE INSTALLWITH ROOF STITCHFASTENER IN MINOR RIBS.

VENTILATOR

FRAMING

PANELRIB

PANELRIB

FLASHING

INSIDECLOSURE

3'-0"3'-0"

PANEL RIBROOF

PANEL RIBSOFFIT

PANEL RIBROOF

EAVEFASCIA

PANEL RIBROOF

MULTI-GUTTER

RAKEFASCIA

PANEL RIB

OUTSIDE CLOSURE ATTACHES WITHWALL STITCH FASTENERS AT MAJORRIBS.

INSIDE CLOSURE WITH ROOFSTRUCTURAL FASTENER ATEACH MINOR RIB AT EAVEMEMBER.

OUTSIDE CLOSURE use std. purlinfastener arrangment for attachingroof panel. Locate closure belowfastener heads-attach ridge vent andclosure with VP-200 rivets located atthe major ribs of each roof panel.

INSIDE CLOSURE at top use roofstitch fastener at 12" O.C.

OUTSIDE CLOSURE at bottom attachwith wall stitch fasteners at majorribs.

OUTSIDE CLOSURE use std.purlin fastener arrangementfor attaching roof panel.Locate closure below fastenerheads. Attach flashing andclosure with roof stitchfasteners at major ribs of eachroof panel.

OUTSIDE CLOSURESoffit trim attached with wallstitch fasteners located at eachmajor rib of wall panel.

PANEL RIB CLOSURE / TYPES & APPLICATIOND-12

03/15/14

Page 54: Basic Panels & Accessories

Design and recommended installation procedures are subject to change at any time, due to continued development work by Varco Pruden Buildings.

• • •All panels formed from light gauge metal may exhibit waviness, also known as “Oil-Canning,” commonly occurring in, but not restricted to, flat portions of a panel. This inherent characteristic is not a defect of material or manufacturing and is not cause for rejection.

• • •For field installation questions, call your local VP Service Center. The job number is included on all building plans:Arkansas: ..................................870-534-6030California: ...................................209-667-4951Missouri:.....................................816-238-7550North Carolina: ...........................336-996-4801Wisconsin: ..................................608-882-5000

Varco Pruden Buildings, 3200 Players Club Circle, Memphis, TN 38125©2012 BlueScope Buildings North America, Inc. All rights reserved.Varco Pruden Buildings® is a division of BlueScope Buildings North America, Inc.

4003 Basic Panels and Accessories Form: EG-902931 Issue Date: 2010Revision: 3 Revised: 2/14