avopiling headquarters
TRANSCRIPT
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
AVOPILING HEADQUARTERS
18-151
S000
COVER SHEET & DRAWING INDEX
SS
CDG
-
-
JAN 19
STRUCTURAL
AVOPILING HEADQUARTERSLOT 320 McCOOK STREET, FORRESTDALE
STRUCTURAL DOCUMENTATION
DRAWING INDEX
SHEET NUMBER SHEET TITLE CURRENT REV
S000 COVER SHEET & DRAWING INDEX
S001 GENERAL NOTES - SHEET 1
S002 GENERAL NOTES - SHEET 2
S005 STANDARD DETAILS - SHEET 1
S006 STANDARD DETAILS - SHEET 2
S007 STANDARD DETAILS - SHEET 3
S008 STANDARD DETAILS - SHEET 4
S101 GROUND LEVEL GA - PART PLAN 1
S102 GROUND LEVEL GA - PART PLAN 2
S200 FIRST FLOOR GENERAL ARRANGEMENT AND OFFICE ROOF
S250 FIRST FLOOR SECTIONS AND DETAILS - SHEET 1
S251 CRANE MAINTENANCE PLATFORM
S300 WORKSHOP ROOF FRAMING PLAN
S350 TRUSS ELEVATIONS AND DETAILS
S351 ROOF SECTIONS & DETAILS - SHEET 1
S400 PANEL LAYOUT PLAN & ELEVATIONS
S401 PANEL ELEVATIONS - SHEET 2
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
GENERAL NOTESTHESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL OTHERDRAWINGS AND SPECIFICATIONS. ALL DISCREPANCIES SHALL BE REFERREDTO THE ARCHITECT FOR DECISION BEFORE PROCEEDING.
ALL DIMENSIONS AND LEVELS SHOWN ON THE DRAWINGS SHALL BEVERIFIED BY THE CONTRACTOR ON SITE. STRUCTURAL DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. REFER TO THE ARCHITECTURALDRAWINGS FOR ALL DIMENSIONS AND SETOUT. THE DESIGN CONSULTANT SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
DURING CONSTRUCTION THE CONTRACTOR SHALL ENSURE THE STRUCTURES IS MAINTAINED IN A STABLE CONDITION ANDNO PART SHALL BE OVERSTRESSED BY EXCESSIVE CONSTRUCTIONLOADING PROVIDE TEMPORARY BRACING AND PROPPING AS REQUIRED.
ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITHTHE CURRENT SAA CODES AND THE BY-LAWS AND ORDINANCES OFTHE RELEVANT BUILDING AUTHORITY EXCEPT WHERE VARIED BYTHE CONTRACT DOCUMENTS.
UNLESS NOTES OTHERWISE ALL DIMENSIONS ARE IN MILLIMETRES AND ALL LEVELS ARE IN METRES.
THE ENGINEER HAS NOT DESIGNED AND IS NOT RESPONSIBLE FORSTRUCTURAL ELEMENTS OTHER THAN THOSE SHOWN ON THE FORTH CONSULTING ENGINEERING DRAWINGS.
THE APPROVAL OF A SUBSTITUTION SHALL BE SOUGHT FROM THEENGINEER BUT IS NOT AUTHORIZATION FOR AN EXTRA.ANY EXTRAS SHALL BE TAKEN UP WITH THE CLIENT BEFOREWORK COMMENCES.
ALL PROPS AND FORMWORK FOR BEAMS AND SLABS SHALL BEREMOVED BEFORE CONSTRUCTION OF ANY MASONRY WALLS ORPARTITIONS ON THE FLOOR
ALL NON-LOAD BEARING WALLS SHALL BE KEPT CLEAR OF THEUNDERSIDE OF SLABS AND BEAMS BY 20mm UNLESS OTHERWISE SHOWN.
THE BUILDER SHALL RECORD ALL VARIATIONS TO THE DRAWINGSAND BE RESPONSIBLE FOR PRODUCING AS CONSTRUCTED DRAWINGSIN ELECTRONIC FORMAT AT THE COMPLETION OF THE WORKS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
DESIGN DATATHE STRUCTURAL COMPONENTS DETAILED ON THESE DRAWINGSHAVE BEEN DESIGNED FOR THE FOLLOWING LOADINGS.
LIVE LOADS ARE IN ACCORDANCE WITH AS 1170.1 – 2002.
WIND LOADS ARE IN ACCORDANCE WITH AS1170.2 – 2011REGIONAL WIND SPEED Vr: 46m/sREGION: A1TERRAIN CATEGORY: 3.0SHIELDING MULTIPLIER: 1.0TOPOGRAPHIC MULTIPLIER: 1.0IMPORTANCE MULTIPLIER: 1.0
SEISMIC LOADS IN ACCORDANCE WITH AS1170.4 – 2007 AS FOLLOWS:EARTHQUAKE DESIGN CATEGORY: IISITE SUB-SOIL CLASS: CeHAZARD FACTOR (Z): 0.09PROBABILITY FACTOR (Kp): 1.0IMPORTANCE LEVEL: 2
THE CONCRETE ELEMENTS HAVE BEEN DESIGNED FOR THEFOLLOWING EXPOSURE CLASSIFICATIONS IN ACCORDANCEWITH AS 3600.
1.
2.
3.
4.
5.
FLOOR USAGE CLASSIFICATION
EXTERIOR CONCRETEINTERIOR CONCRETE
A1A1
FLOOR USAGE SUPERIMPOSED DEAD LOADS(kPa)
LIVE LOAD(kPa)
SLAB ON GROUNDROOFOFFICE
0.50.50.5
10.00.253.0
CONCRETEALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS3600.
ALL CONCRETE SHALL BE PREMIXED BY AN APPROVED SUPPLIER.
ALL CEMENT SHALL BE TYPE A-ORDINARY PORTLAND CEMENTUNLESS SPECIFIED OTHERWISE.
ADMIXTURES SHALL NOT BE USED UNLESS APPROVED IN WRITINGBY THE ENGINEER.
CONCRETE SHALL BE NORMAL CLASS CONCRETE COMPLYING WITHAS3600, UNLESS SPECIFIED OTHERWISE.
CONCRETE STRENGTH AND CLEAR CONCRETE COVER TO REINFORCEMENTSHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE UNLESS NOTEDOTHERWISE (U.N.O). ELEMENTS NOT COVERED SHALL BE IN ACCORDANCEWITH AS3600.
SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FINISHES.
BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS.
NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSESHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETEELEMENTS WITHOUT PRIOR APPROVAL OF THE ENGINEER.
CONSTRUCTION JOINTS SHALL BE PROPERLY FORMED AND USED ONLYWHERE SHOWN OR SPECIFICALLY APPROVED BY THE ENGINEER.
SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN POSITIONSSHOWN OR OTHERWISE APPROVED IN WRITING BY THE ENGINEER.LAPS SHALL BE IN ACCORDANCE WITH THE FOLLOWING:
MESH SHALL BE LAPPED SUCH THAT THE TWO OUTERMOSTWIRES OF ONE SHEET OVERLAP THE TWO OUTERMOST WIRESOF THE OTHER SHEET BY 25mm MINIMUM.
A MAXIMUM OF THREE SHEETS OF MESH SHALL BE LAPPEDAT ANY POINT.
ELEMENT
BLINDING &MASS CONCRETEFOOTINGSSLAB ON GROUNDMEZZANINE SLABTILT-UP WALLSAFS WALLS
EXPOSED TO WEATHERCONCRETEGRADE (MPa) 15
25 32 32 40 40
REINF.COVER -
50 30 40 40 40
NOT EXPOSED TO WEATHERCONCRETEGRADE (MPa) 15
25 32 32 40 40
REINF.COVER -
50 30 40 40 40
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
SPLICE LAP LENGTH (mm)
BAR BOTTOM BAR LAP TOP BAR LAP
N12N16N20N24N28N32N36
4506008501100140017002050
55080011001100110017002050
25 MIN
FOUNDATIONSITE ASSESSED TO BE CLASS 'A' (STABLE), AS DEFINED AS 2870 "RESIDENTIAL SLABS AND FOOTINGS" AND AS SPECIFIED IN THE GEOTECHNICAL REPORT PREPARED BY 'UTS SOILTEC PTY LTD REFERENCE No: R1575.
EXISTING GROUND CONSISTS OF SAND OF VARYING COMPACTION,WITH A SITE CLASSIFICATION (TO AS2870) OF CLASS 'A'.
GROUND TO UNDERSIDE OF FOOTINGS AND SLABS ON GROUNDSHALL BE COMPACTED BY HAND OR WITH AN APPROVED VIBRATORYPLATE COMPACTOR OR ROLLER TO ACHIEVE A COMPACTION IN THETOP 750mm EQUIVALENT TO 8 BLOWS PER 300mm MEASURED WITH A9.1kg 16mm DIAMETER STANDARD PERTH PENETROMETER.
DO NOT USE COMPACTION METHODS THAT WILL CAUSE DAMAGE TOADJACENT STRUCTURES. SELECTION OF METHODS SHALL BE THEBUILDER'S RESPONSIBILITY.
SITE SHALL BE STRIPPED OF ALL VEGETATION IN THE BUILDING AREAS.ENSURE THAT NO VEGETATION OR ORGANIC MATTER EXISTS IN THE SOILSTRATA BELOW THE FOOTING OR SLAB ON GROUND FOR A DEPTH OF ATLEAST 1000mm.
COMPACT FOUNDATION MATERIAL AND BACKFILL IN LAYERS NOTEXCEEDING 300mm TO 95% MODIFIED MAXIMUM DRY DENSITY INACCORDANCE WITH AS 1289. PROVIDE COMPACTION TEST RESULTSPRIOR TO PROCEEDING.
REQUIRED FILL SHALL BE CLEAN, WELL GRADED SAND ALL FILLSHALL BE APPROVED PRIOR TO PLACEMENT SAND MATERIALEXCAVATED FROM THE SITE SHALL NOT BE SUITABLE FOR BACKFILLWITHOUT PRIOR ENGINEER APPROVAL.
TENDERERS SHALL PROVIDE A RATE PER CUBIC METRE EXTRA OVERTO SAND, FOR ROCK EXCAVATION, SHOULD THIS BE REQUIRED.
LOCATE FOOTINGS CENTRALLY UNDER WALLS AND COLUMNS UNLESSOTHERWISE NOTED.
DO NOT BACKFILL RETAINING WALLS (OTHER THAN CANTILEVER WALLS)UNTIL FLOOR CONSTRUCTION AT TOP AND BOTTOM IS COMPLETE ENSUREFREE DRAINAGE BACKFILL AND DRAINAGE IS IN PLACE.
FOUNDATIONS HAVE BEEN DESIGNED FOR THE FOLLOWING ALLOWABLEPRESSURE: 200 KPa.
THE BUILDER SHALL ARRANGE FOR ALL DENSITY OR PENETROMETERTESTING TO BE CARRIED OUT BY AN APPROVED TESTING LABORATORY.THE TESTS SHALL BE CARRIED OUT IN ACCORDANCE WITH THE FOLLOWINGSCHEDULE:
UNDER PAD FOOTINGS:……………………….... 1 TEST/ 10m² (MINIMUM OF1 TEST / FOOTING)
UNDER STRIP FOOTINGS:…………………..... 1 TEST/ 5m LENGTHUNDER SLABS:………………………………............1 TEST/ 20m²
NO EXCAVATION SHALL BE CARRIED OUT CLOSER TO FOOTINGS THANA LINE EXTENDING DOWN FROM THEIR EDGE AT 45 DEGREES.
FOUNDATIONS ADJACENT TO SERVICES, EXCAVATIONS OR BATTER ETC.SHALL BE EXTENDED DOWN SUCH THAT THE INFLUENCE LINE OF THEFOUNDATIONS IS BELOW THE ADJACENT SERVICE AS SHOWN BELOW.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
30.00°
LINE OF INFLUENCE
BACK FILLED SERVICE TRENCHOR OTHER EXCAVATIONNEW FOOTING OR SLAB
PROVIDE 15MPa LEAN MIXCONCRETE WHERE NECESSARY
REINFORCEMENTREINFORCEMENT SYMBOLS;N - GRADE 500 PLUS REBAR TO AS/NZS 4671SL - GRADE 500 DEFORMED HARD DRAWN WIRE REINFORCING FABRIC TO AS1304.W - HARD DRAWN PLAIN WIRE TO AS1303R - GRADE 250R HOT ROLLED PLAIN BAR TO AS1302
REINFORCEMENT NOTATION:
N12-300 3N28
REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE POSITION.
ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION BY APPROVED MEANS BEFORE PLACING CONCRETE.
WELDING AND/OR SITE CUTTING OF REINFORCING SHALL NOT BE PERMITTED UNLESS APPROVED IN WRITING BY THE ENGINEER.
SLABS ON GRADE SHALL BE UNDERLAIN WITH A CONTINUOUS LAYER OF A 200 MICRON THICKNESS WATERPROOFING MEMBRANE LAPPED AND TAPED TO MANUFACTURERS DETAILS.
ALL PROPRIETARY FIXINGS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
CONCRETE SURFACES SHALL BE MONOLITHICALLY FINISHED TO A FLAT UNIFORM SURFACE IN ACCORDANCE WITH AS3610.
WHERE POSSIBLE SLABS ON GROUND SHALL BE PLACED USING VIBRATING SCREEDS.
ALL CONCRETE SHALL BE COMPACTED USING A MECHANICAL VIBRATION PROCESS.
SPACING (mm)BAR SIZE (mm)TYPE OF REINF.
BAR SIZE (mm)TYPE OF REINF.NUMBER OF BARS
1.
2.
3.
4.
5.
6.
7.
8
9.
10.
STRUCTURAL STEELALL STEELWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AS4100ASN AS1554.
ALL STEEL WORK SHALL BE NEW AND COMPLYING WITH THE FOLLOWING MIN GRADES UNO:i) OPEN SECTIONS 300MPaii) RHS/SHS 450MPaiii) CHS 350MPaiv) FLAT PLATES 250MPa
ALL STEEL WORK SHALL BE PRODUCED IN AUSTRALIA AND CERTIFIED AS BEING COMPLIANTWITH THE RELEVANT AUSTRALIAN STANDARDS THE CONTRACTOR SHALL MAKE AVAILABLETO THE ENGINEER, IF REQUESTED, NATA ACCREDITED LABORATORY TEST DATA TODEMONSTRATE THIS. IN THE CIRCUMSTANCES WHERE THE CONTRACTOR WISHES TO USEIMPORTED STEEL, HE SHALL PROPOSE THIS IN WRITING TO THE ENGINEER PRIOR TO TENDERING.THE CONTRACTOR SHALL INCLUDE ALL ASSOCIATED NATA ACCREDITED LABORATORY MILLCERTIFICATES DEMONSTRATING FULL COMPLIANCE WITH THE RELEVANT AUSTRALIANSTANDARDS. THE ENGINEER RESERVES THE RIGHT TO ACCEPT OR REJECT SUCH A PROPOSAL.
GRADE 4.6 BOLTS SHALL BE TO AS111. GRADE 8.8 BOLTS SHALL BE TO AS1252.
BOLT DESIGNATION (EXAMPLE) = 5M20/SNUMBER BOLTS = 5 NoSIZE M20 = Ø20mmTIGHTENING /S = SNUG TIGHTENED
/TB = FULLY TENSIONED BEARING CONNECTION/TF = FULLY TENSIONED FRICTION TYPE CONNECTION.
FINGER TIGHT = TIGHTENED WITH HAND SPANNER THEN TURNED BACK HALF A TURN AGAINST APPROVED LOCK NUT.
UNLESS OTHERWISE NOTED ALL BOLTS M20 SHALL BE GRADE 8.8/S (SNUG TIGHT). NOTHREADS SHALL BE PERMITTED IN THE SHEAR PLANE.
ALL BOLTS, NUTS AND ACCESSORIES SHALL BE HOT DIP GALVANISED TO AS/NZS4680.
ALL WELDING SHALL BE TO AS1554, PART 1. ALL WELDS SHALL BE APPLIED WITHE48XXX ELECTRODES. WELDS SHALL BE 6mm CONTINUOUS FILLET (6CFW) UNLESSOTHERWISE NOTED. ALL WELDING SHALL BE CARRIED OUT BY AN EXPERIENCEDOPERATOR. STEELWORK SHALL BE CLEANED BACK TO WHITE METAL SURFACE ANDFREE OF RUST, SCALE, ETC. PRIOR TO WELDING. PURLIN AND GIRT CLEATS SHALL BECATEGORY GP WELDS. ALL OTHER WELDS SHALL BE CATEGORY SP UNLESS NOTEDOTHERWISE. SUPERVISE AND TEST ALL CATEGORY SP WELDS IN ACCORDANCE WITHAS1554.
CFW DENOTES CONTINUOUS FILLET WELD TO AS1554/1. FSBW DENOTES PREQUALIFIED,FULL PENETRATION BUTT WELD TO AS1554/1.
SECTIONS SHALL NOT BE SPLICED OTHER THAN AT JOINTS SHOWN, UNLESS APPROVEDBY THE ARCHITECT.
THE CONTRACTOR SHALL PREPARE WORKSHOP DRAWINGS FOR REVIEW. FABRICATIONSHALL NOT COMMENCE UNTIL THE DRAWINGS HAVE BEEN EXAMINED AND RETURNED. COORDINATE THE INPUT OF ALL TRADES ON THE WORKSHOP DRAWINGS.
UNLESS OTHERWISE SHOWN, ALL CLEAT, GUSSETS, ENDS AND STIFFENER PLATESSHALL BE 10mm THICK. MINIMUM BOLTED CONNECTION SHALL BE 2M20/S
THE CONTRACTOR SHALL PROVIDE ALL CLEATS AND HOLES WHETHER OR NOT SHOWNFOR FIXING NON STRUCTURAL ELEMENTS OF STEELWORK.
PROTECTIVE SURFACE TREATMENT SHALL BE:STEELWORK CAST INTO CONCRETE:HOT DIP GALVANISED IN ACCORDANCE WITH AS/NZS4680 RATE 600gm/m²
EXTERIOR STRUCTURAL STEELWORK:HOT DIP GALVANISED IN ACCORDANCE WITH AS/NZS4680 RATE 600gm/m².TOP COAT TO ARCHITECT'S SPECIFICATIONS.
STEELWORK IN CONTACT WITH SOIL:TAR EPOXY SECONDARY COAT (200 MICRONS DFT) IN ADDITION TO ABOVEREQUIREMENTS.
PURLINS AND GIRTS:ALL PURLINS AND GIRTS TO BE FROM G450 STEEL AS1397.
PURLINS AND GIRTS ARE DESIGNED NOTED ON DRAWINGS IN ACCORDANCE WITHMANUFACTURER'S DETAILS.
GROUT UNDER ALL SEATING AND BASE PLATES WITH PROPRIETARY DRY PACKSYSTEM – ENSURE SPACE UNDER PLATES IS COMPLETELY FILLED.
ALL COMPONENTS TO BE CAST INTO CONCRETE (HOLDING DOWN BOLT, BRACKETS,ETC.) SHALL BE HOT DIP GALVANISED TO AS/NZS4680 AFTER FABRICATION.
THE ENDS OF ALL TUBULAR MEMBERS ARE TO BE SEALED WITH NOMINAL THICKNESSPLATES AND CONTINUOUS FILLET WELD UNLESS NOTED OTHERWISE.
ALL HANDRAILING SHALL BE MONOWILLS OR EQUIVALENT AND SHALL HAVE KICKPLATES AS REQUIRED. A STANCHION SHALL BE LOCATED 300mm FROM ALL CHANGESOF DIRECTION AND ENDS OF HANDRAILING. FIXINGS OF STANCHIONS TO CONCRETEWHERE APPLICABLE SHALL BE BY 2/M16 APPROVED MASONRY ANCHORS.MINIMUM DISTANCE TO EDGE OF CONCRETE SHALL BE 100mm.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
GRATING SHALL BE WEBFORGE OR SIMILAR APPROVED, HOT DIP GALVANISEDAFTER FABRICATION AND INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S DETAILS.
STRUCTURAL STEEL SHALL COMPLY WITH ALL REQUIREMENTS OF THE RELEVANTAUSTRALIAN STANDARDS. MANUFACTURER'S OF STRUCTURAL STEEL SHALL HOLDA VALID CERTIFICATE OF APPROVAL ISSUED BY AN ACCEPTABLE THIRD PARTYCOMPLIANCE ASSESSMENT BODY (SUCH AS THE AUSTRALIAN CERTIFICATIONAUTHORITY FOR REINFORCING STEEL (ACRS)). EVIDENCE OF COMPLIANCE MUST BESUBMITTED WHEN TENDERING AND AS A PART OF THE QUALITY ASSURANCEPROCESS.
UNLESS BRIDGING IS SPECIFICALLY STATED ON THE STRUCTURAL DRAWINGS,MINIMUM BRIDGING REQUIREMENTS FOR STEEL PURLINS SHALL BE 2 ROWS INEND SPANS AND 1 ROW IN INTERNAL SPANS FOR ANY SPANS MORE THAN 2500mm
ALL ROOF BRACING SHOWN ON THE STRUCTURAL DRAWINGS IS TO BE HOOK BOLTEDTO THE WEB OF THE PURLINS, BRACE WITH 10mm DIA HOOK BOLTS.
ALL WALL AND ROOF BRACING IS TO BE INSTALLED IN A TAUGHT FASHION, FREEFROM SLACK, DISTORTION DEVIATIONS AND THE LIKE USE SUITABLE TENSIONINGMECHANISM AS APPROPRIATE ALL RODS TO HAVE TURNBUCKLES OR SIMILAR DEVICE
CEILING SYSTEMS, DUCTWORK ETC. TO BE SUSPENDED FROM PURLINS SHOULD BEFIXED WITH HOOK BOLTS THROUGH THE PURLIN WEBS. THE FLANGES OF THEPURLINS OR GIRTS SHALL NOT BE HOLED.
WHILST THE STRUCTURAL STEEL SECTIONS, PLATES, PURLINS, CONNECTORS AND ALL OTHER STEEL MEMBERS INCLUDED ON THESE DRAWINGS HAVE BEEN CHECKEDFOR AVAILABILITY AT THE TIME OF DESIGN, THERE IS NO GUARANTEE THAT ALLSTEELWORK ITEMS WILL BE AVAILABLE AT THE TIME OF FABRICATION. ALLSTEELWORK TENDERS AND SUBCONTRACT PRICES SHALL BE DEEMED TO INCLUDEALL COSTS RELATED TO ANY NECESSARY SUBSTITUTIONS DUE TO THEUNAVAILABILITY OF SECTIONS, MEMBERS AND OTHER STEELWORK ITEMS. ALLSUBSTITUTIONS SHALL BE CHECKED AND APPROVED BY THE ENGINEER PRIOR TOTHE COMMENCEMENT OF SHOP DRAWINGS.
19.
20.
21.
22.
23.
24.
25.
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S001
SHEET 1GENERAL NOTES
SS
CDG
-
-
JAN 19
STRUCTURAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
PRECAST (TILT-UP) CONCRETEALL PRECAST CONCRETE IS TO COMPLY WITH THE SPECIFICATION.
COMPLY WITH ANY NATIONAL, STATE OR TERRITORY CODES OF PRACTICE OF
INDUSTRY STANDARD FOR PRECAST AND TILT-UP CONSTRUCTION FOR INCLUDING
BUT NOT LIMITED TO THE WORKSAFE WA, CODE PRACTICE, TILT-UP AND PRECAST
CONCRETE CONSTRUCTION, THE WORKSAFE VICTORIA, INDUSTRY STANDARD,
PRECAST AND TILT-UP CONCRETE FOR BUILDINGS OR THE WORKPLACE HEALTH
AND SAFETY QUEENSLAND, TILT-UP AND PRECAST CONSTRUCTION, INDUSTRY
CODE OF PRACTICE, AS APPLICABLE.
THE PRECAST CONCRETE SHALL COMPLY WITH AS3600 CONCRETE STRUCTURES,
AS3610 FORMWORK FOR CONCRETE AND PRECAST FLAT PANELS TO AS3850
TILT-UP CONCRETE CONSTRUCTION. PROVIDE A COPY OF AS3850 ON SITE FOR
ANY PRECAST FLAT PANELS ERECTED IN A VERTICAL POSITION. FORMWORK
SHALL BE CLASS 1 TO AS3610 UNLESS OTHERWISE NOTED. REFER ALSO TO
CIA Z48-2002, THE CIA PRECAST CONCRETE HANDBOOK. ALL STEEL ITEMS CAST
INTO THE CONCRETE SHALL COMPLY WITH AS4100, ALL WELDING SHALL COMPLY
WITH AS1554 AND ALL GRADE 4.6 BOLTS AND GRADE 8.8 SHALL COMPLY
WITH AS1111 AND AS1252 RESPECTIVELY.
FOR LOCATIONS AND DIMENSIONS OF PRECAST UNITS REFER TO THE
ARCHITECTURAL DRAWINGS.
THE PRECAST HAS TO BE DESIGNED FOR THE IN PLACE CONDITION AND THE
CONTRACTOR MUST MAKE AN ASSESSMENT AS TO ANY EXTRA REINFORCEMENT
ETC., THAT MAY BE REQUIRED TO SUIT THE PROPOSED TRANSPORTATION, HANDLING
AND ERECTION METHODS. ANY SUCH EXTRA MATERIALS OR OTHER HANDLING
REQUIREMENTS MUST BE ALLOWED FOR IN THE TENDER.
WHERE REQUIRED BY LEGISLATION OF TO SUIT STATUTORY REQUIREMENTS, USE
AN EXPERIENCED ENGINEER, DESIGNATED AS THE ERECTION DESIGN ENGINEER
WHO IS RESPONSIBLE FOR DESIGNING THE PRECAST FOR HANDLING AND ERECTION
INCLUDING BRACING. TILT-UP TO BUILDINGS, OR PORTIONS OF BUILDINGS THAT
ARE GREATER THAN ONE PANEL IN HEIGHT, OR INCORPORATE WALL PANELS
GREATER THAN 8m IN HEIGHT OR INCORPORATE WALL PANELS WEIGHING MORE
THAN 8 TONNE OR INCORPORATE WALL PANELS WHICH ARE NOT NOMINALLY
FLAT OR RECTANGULAR OR WHERE WALL PANELS ARE NOT DIRECTLY FIXED
AND SUPPORTED BY A FREE STANDING STRUCTURAL FRAME SHALL REQUIRE AN
ERECTION DESIGN ENGINEER.
THE CONTRACTOR SHALL SUBMIT FOR REVIEW IF REQUIRED BY THE SUPERINTENDENT,
FULL DETAILS IN WRITING OF THE PROPOSED HANDLING AND ERECTION OF PRECAST
PANELS INCLUDING A WORK METHOD STATEMENT. WHEN A DESIGN ERECTION ENGINEER
IS REQUIRED, SUBMIT THE COMPUTATIONS FOR ERECTION ON REQUEST. THIS REVIEW
SHALL COVER THE HANDLING PROCEDURE OF THE UNITS THROUGHOUT ALL STAGES
INCLUDING STRIPPING, LIFTING, STACKING, TRANSPORTING AND ERECTION. CONCRETE
STRESSES THROUGHOUT HANDLING SHALL NOT CAUSE CRACKING. THE REVIEW SHALL
INCLUDE THE LOCATION AND SIZE OF LIFTING AND BRACING INSERTS, TESTS OR
MANUFACTURER'S WRITTEN DATA PROVING THE CAPACITY OF LIFTING INSERTS,
BRACING INSERT, THE BRACING AND THE BRACE ANCHORS. ALL OF THIS WILL BE
DONE IN ACCORDANCE WITH AS3850 IF APPLICABLE.
REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, SETOUT, JOINT
LAYOUTS, REQUIRED REBATES, FERRULES, DRIPS, SEALS AND BAFFLES,
WATERPROOFING ETC. AND EDGE DETAILS FOR GLAZING AND WINDOWS, DOOR OPENINGS,
PANEL LOCATIONS AND DIMENSIONS AND THE LIKE. ARCHITECTURAL FIXINGS FERRULES
ARE TO BE LOCATED WHERE NECESSARY TO SUIT ARCHITECTURAL DETAILS.
ALL FLASHINGS SHALL BE FIXED TO CAST IN REGLETS. SAW CUTTING REGLETS
WITHOUT WRITTEN INSTRUCTIONS IS NOT PERMITTED.
THE CONTRACTOR SHALL REFER TO ALL OTHER TRADES TO ENSURE THAT OPENINGS
ARE LEFT WHERE NECESSARY AND THAT FIXINGS, FITTINGS AND ASSOCIATED
COMPONENTS REQUIRED BE INSTALLING ARE PROVIDED AND BUILT IN AS THE WORK
PROCEEDS.
SHOP DRAWINGS OF ALL PRECAST UNITS ARE TO BE DRAWN AND SUBMITTED TO THE
SUPERINTENDENT TO ENABLE REVIEW AND ALTERATIONS IF NECESSARY TO BE MADE,
PRIOR TO MANUFACTURE. REFER ALSO TO THE SPECIFICATIONS.
REFER TO THE SPECIFICATIONS FOR THE SUPPLY OF SAMPLES AND PROTOTYPES.
REINFORCING FABRIC IN PANELS SHALL BE OF ONE SHEET AND LAPPING IS NOT PERMITTED
UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE ENGINEER. ALL
REINFORCING SHOWN IS FOR THE PRECAST UNITS IN THEIR IN PLACE POSITION.
THE ONLY PLASTIC BAR CHAIRS TO SUPPORT REINFORCING AND HANG REINFORCING FROM
THE BACK OF THE PRECAST UNIT SO THAT THERE ARE NO EXPOSED BAR CHAIRS ON THE
EXPOSED FACES TO VIEW.
PROVIDE 1N12 TRIMMER BAR PER LAYER OF REINFORCING ALL ROUND, ALL EDGES OF THE
PRECAST UNITS. PROVIDE N12 CORNER BARS BY 1000 LONG FOR EACH LAYER OF
REINFORCING AT 45 DEGREES AT CORNERS OF DOORS AND WINDOW OPENINGS AND THE LIKE.
LAPS IN BARS = N12-300mm, N16-400mm, N20-500mm UNO.
BARS AND FABRIC TO HAVE A CRANK OF 1:6 MAX. U.N.O. ALL COGGED BARS AND
FITMENTS. TO HAVE 5db BENDS. PROVIDE AS ALTERNATIVE TO BARS PROTRUDING FROM
PRECAST UNITS FOR LAPPING WITH SLAB REINFORCEMENT,EITHER A CAST IN FERRULE
WITH SCREW IN BARS (SCREW IN BARS TO BE THREADED FROM A BAR LARGER THAN THE
FERRULE E.G USE N16 BAR FOR A M12 FERRULE) OR REID BAR COUPLERS WITH ANCHOR
BAR AND REID BAR DOWEL BAR, WHERE SUCH BARS WOULD INTERFERE WITH THE FIXING
OF FORMWORK OR REINFORCEMENT. SEEK APPROVAL FOR THESE ALTERNATIVES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
FOR PANELS WITH A SINGLE LAYER OF REINFORCING AND VERTICAL GROUT TUBE
(DUCTS) PARALLEL TO THE PLANE OF THE REINFORCING, CUT THE HORIZONTAL
REINFORCEMENT LOCALLY FOR THE GROUT TUBE AND PROVIDE ADDITIONAL 2N12
BY 400mm LONG EACH SIDE OF GROUT TUBE HORIZONTALLY AT 100 CENTRES.
CONCRETE COVER ON EXPOSED FACE IS TO BE 40mm UNO. REBATES OF 15mm OR
LESS ON EXPOSED FACE REDUCE COVER TO 25mm OTHERWISE INCREASE COVER
FOR DEEPER REBATES. COVER ON INTERNAL FACE 30mm. TOLERANCE ON COVER
IS +5mm, -0mm UNO.
THE CONTRACTOR SHALL SUPPLY AND FIT LIFTERS AS REQUIRED TO HANDLE AND
ERECT THE PRECAST UNITS. THESE SHALL BE CAST IN PROPRIETARY LIFTERS. THEY
SHALL NOT BE LOCATED IN THE FACE WHICH IS EXPOSED TO THE VIEW IN THE
FINAL CONDITION.
ALL CAST-IN FERRULES AND ALL BRACING INSERTS (FERRULES) ARE TO BE
M20x95 UNO AND ARE TO BE REID ELEPHANT'S FEET FERRULES AND TO HAVE
N12x400 LONG CROSS BAR SECURELY ANCHORED BEHIND THE REINFORCING UOS.
ALL FERRULES ARE TO BE SUPPLIED BY REID OR AN APPROVED SUPPLIER AND
ALL FERRULES SHALL HAVE TEST DATA CONFIRMING THEIR LOAD CAPACITIES IN
ULTIMATE LIMIT AND WORKING LOAD LIMIT (WLL) TO AS3850.
PROVIDE DOWEL BARS EITHER AS A LOOSE BAR, OR A CAST IN BAR OR A BAR
SCREWED INTO A FERRULE OR COUPLER. PROJECTING FROM A PRECAST UNIT OR
FROM INSITU CONCRETE WHICH FITS INTO A GROUT TUBE IN THE MATING SECTION.
PROVIDE THREADED REINFORCING BAR (GRADE N500) WHERE SHOWN AND SCREWED
INTO A CAST IN FERRULE IN THE PRECAST UNIT. PROVIDE REID BAR SCREWED INTO
A REID COUPLER OR JOINER WHERE SHOWN ON THE DRAWINGS.
PROVIDE GROUT TUBES AS SHOWN MADE FROM THIN WALL GALVANISED METAL
DUCT (VSL ROUND DUCT) CAST INTO EITHER INSITU CONCRETE OR THE PRECAST
ELEMENT INTO WHICH A REINFORCING BAR, EITHER DOWEL BAR OR A BAR FROM
THE PRECAST UNIT WILL FIT AND IS THEN GROUTED IN PLACE. DO NOT USE
PLASTIC TUBE TO ENCAPSULATE THE DOWEL BAR.
PROVIDE THE PURPOSE MADE STEEL BRACKETS WITH BARS, BOLTS OR STUDS
WELDED TO THEM CAST INTO THE CONCRETE AND TO WHICH STRUCTURES IS
ATTACHED TO OR WHICH ARE USED TO BE SUPPORT FOR THE PRECAST UNIT ON
THE STRUCTURE. BOLTS AND STUDS TO PLATES AND BOLTS CAST INTO THE
PRECAST TO BE GRADE 4.6 UNO.
ALL PROPRIETARY CAST IN CONNECTOR PLATES SHALL CONFORM TO AS4100 WITH
APPROVED TEST DATA TO CONFIRM THE LOAD CAPACITIES USED ON REQUEST.
BOLTS AND STUDS TO PLATES AND BOLTS CAST INTO THE PRECAST ARE TO
BE GRADE 4.6 UNO.
THE METAL FIXINGS, FERRULES, BOLTS, NUTS, WASHERS, LIFTERS, CAST IN ITEMS
ETC. ARE TO BE HOT DIP GALVANISED IN ACCORDANCE WITH AS4680 UOS. USE
ONLY GRADE 4.6 OR 8.8 BOLTS AS SPECIFIED. DO NOT WELD, INCLUDING TACK
WELD, 8.8 BOLTS OR NUTS UNDER ANY CIRCUMSTANCES.
ALL PANELS ARE TO BE CONSTRUCTED FROM NORMAL WEIGHT CONCRETE. THE
CONCRETE IN THE PRECAST UNITS SHALL BE AS SHOWN ON THE DRAWINGS BUT
NOT LESS THAN f'c = 40MPa. THE MINIMUM CEMENT CONTENT FOR THE PRECAST
UNITS IS TO BE 420kg/m AND A WATER CEMENT RATIO NOT EXCEEDING 0.5 UOS.
THE CONTRACTOR SHALL SUBMIT HIS PROPOSED CONCRETE MIX DESIGN FOR
APPROVAL PRIOR TO CASTING OF UNITS.
COMPACT THE CONCRETE USING VIBRATING TABLE., VIBRATING FORM AND VIBRATORS
TO ACHIEVE DENSE WELL COMPACTED CONCRETE.
THE CONCRETE STRENGTH AT REMOVAL FROM MOULDS IS TO BE A MINIMUM OF 15MPa
ALL CONCRETE CORBELS TO THE PRECAST PANELS TO BE POURED MONOLITHICALLY
WITH THE PANEL.
THE PRECAST UNITS MUST BE STACKED IN SUCH A WAY THAT CRACKING WILL NOT
OCCUR AND WARPING IN EXCESS OF THAT GIVEN IN THE RELEVANT CODES WILL
NOT OCCUR.
ACCEPTANCE OF THE COMPLETED PRECAST UNITS BY THE SUPERINTENDENT WILL BE
UPON DELIVERY AND ERECTION ON THE SITE. PRECAST UNITS WHICH ARE CRACKED
OR DAMAGED ON DELIVERY IN ANY MANNER SHALL BE REJECTED PRIOR TO ERECTION.
LIKEWISE ANY PRECAST UNITS DAMAGED DURING OR FOLLOWING ERECTION, SHALL BE
REMOVED AND REPLACED BY THE CONTRACTOR OR WHERE APPROVED, SHALL BE
REPAIRED IN ACCORDANCE WITH THE SPECIFICATION.
DO NOT ERECT TILT-UP ON STRUCTURE SUCH AS SLABS ON GROUND UNTIL THEY ARE
AT LEAST 3 DAYS OLD AND HAVE REACHED THEIR DESIGN STRENGTH OR ON
SUSPENDED STRUCTURE UNTIL THEY ARE AT LEAST 28 DAYS OLD AND HAVE
REACHED THEIR DESIGN STRENGTH. SEEK APPROVAL IN WRITING TO REDUCE THESE
TIMES AND ALLOW FOR ALL COSTS OF INCREASED CONCRETE STRENGTHS, SHORING ETC.
IF APPROVAL IS GIVEN.
ERECT THE PRECAST UNITS IN A SAFE AND CORRECT MANNER IN ACCORDANCE WITH
RELEVANT CODES OR PRACTICE, LEGISLATION OR TO SUIT STATUTORY REQUIREMENTS.
THE ERECTION DESIGN WILL INCLUDE BUT NOT LIMITED TO THE FOLLOWING, LIFTING
INSERTS, RIGGING SYSTEM, BRACES, BRACE FIXINGS AND THE BRACE FOOTINGS. THE
ERECTION DESIGN ENGINEER IS TO CARRY OUT PERIODIC INSPECTIONS (2 MINIMUM
FOR EACH TYPE OF UNIT) OF THE BRACING ON SITE TO ENSURE THE INTENT OF THE
BRACING DESIGN IS BEING CARRIED.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
DESIGN THE BRACING TO WALL PANELS TO AS3850. ENSURE ALL WALL PANELS ARE
SECURELY FIXED AT THEIR BASE WITH AT LEAST TWO FIXING. ONE AT EACH END. DO
NOT USE FRICTION FOR RESTRAIN OF THE BASE OF THE PANELS UNLESS IT IS
POSITIVELY RESTRAINED. BRACING TO BE AT 45-60 DEGREES TO THE HORIZONTAL
AND TO CONNECT AT ABOUT 2/3 HEIGHT OF PANEL UNLESS OTHERWISE DESIGNED BY
THE ERECTION DESIGN ENGINEER. BRACING (PROPS) TO CONNECT TO M20 FERRULES
(BRACE INSERTS), CAST INTO THE BACK OF THE PRECAST PANEL WITH AN M20 BOLT
GRADE 8.8/S. ALL BRACING PROPS SHALL BE SUPPLIED BY RJB, SHISHAM DURAGAL
OR AN APPROVED SUPPLIER WITH TEST DATA FOR THEIR LOAD CAPACITY TO BE
SUPPLIED ON REQUEST.
PROVIDE 300mm MIN. BETWEEN BRACING INSERTS AND EDGE OF CONCRETE. USE.
PROPRIETARY BRACES (PROPS) WITH KNOWN WORKING LOAD CAPACITY
WITH A MIN. OF 2 BRACES PER PANEL. THE BRACE FOOTING IS TO BE DESIGNED FOR
THE TEMPORARY ERECTION LOADS AND IF IT IS A SEPARATE FOOTING IT MUST
BE FOUNDED IN UNDISTURBED NATURAL GROUND. IF THE BRACE FOOTING IS THE
FLOOR SLAB IT MUST BE A MIN. OF 125mm THICK WHERE THE BRACING INSERTS
ARE TO BE FIXED. THE FLOOR SLAB MUST ALSO BE CAST FOR AT LEAST 3 DAYS
WITH A MIN. STRENGTH OF 20MPa BEFORE ANY DRILLED FIXING CAN BE FIXED.
FOR DRILLED FIXINGS USED FOR BRACING INSERTS, USE THICK SHIELD, HIGH
PERFORMANCE, LOAD CONTROLLED ANCHORS WHICH HAVE BEEN TESTED IN
ACCORDANCE WITH APPENDIX A OF AS3850. LOAD CONTROLLED ANCHORS ARE TO
BE TORQUED UP TO THE REQUIRED TORQUE AS SPECIFIED BY THE MANUFACTURER
USING A CALIBRATED TORQUE WRENCH.
COILS BOLTS, DEFORMATION CONTROL ANCHORS OR CHEMICAL ANCHORS MUST NOT
BE USED.
ADVISE IN WRITING WHEN THE BRACING TO THE WALL PANEL IS TO BE REMOVED
IN ACCORDANCE WITH SECTION 7 OF AS3850. IF IT IS PROPOSED TO REMOVE THE
BRACES BEFORE THE STRUCTURE IS COMPLETE ENSURE THE STRUCTURE IS STABLE
AND IS ADEQUATELY BRACED TO ALLOW THE BRACING TO BE REMOVED AND SEEK
APPROVAL FOR THIS REMOVAL.
PROVIDE PROPPING AND BRACING OF PRECAST FLOOR UNITS AND PRECAST BEAMS
ALLOWING FOR OUT OF BALANCE FORCES DUE TO ERECTION OR CONSTRUCTION ON
ONE SIDE REQUIRED. ALLOW TO SUPPORT ALL CONSTRUCTION LOADS INCLUDING THE
FULL SELF WEIGHT OF THE COMPLETED FLOOR SYSTEM AND POSSIBLE LOCAL
CONCENTRATIONS OF LOAD DURING CONSTRUCTION.
ENSURE PROPS ARE VERTICAL AND BRACE TO PREVENT SIDE-SWAY AND LATERAL
MOVEMENT OF THE WHOLE ASSEMBLY AND THE BUCKLING OF INDIVIDUAL PROPS.
PLACE PROPS AND FORMWORK SUPPORTING PRECAST BEAM OVER COMPLETED
PRECAST CONCRETE BEAMS UNDER. DO NOT SUPPORT PROPS AND FORMWORK ON
PRECAST FLOOR PANELS.
ALSO PROVIDE PROPPING TO SUSPENDED INSITU CONCRETE STRUCTURE TO SUPPORT
ALL PRECAST ACTION (LOADS) WERE THE PRECAST IS TO BE ERECTED BEFORE THE
INSITU STRUCTURE HAS ACHIEVED ITS 28 DAY STRENGTH.
WHERE PRECAST IS TO BE ERECTED ON STEEL BEAM ENSURE THE BEAMS CANNOT
ROTATE AND ALLOW FOR LING AND LEVELLING.
ALL GAPS SHALL BE PROPERLY SEALED WHEN GROUTING UP THE PRECAST
CONNECTIONS TO AVOID THE GROUT FILLING THE GAP BETWEEN THE PANEL AND
THE STRUCTURE AND TO AVOID GROUT SPOILING THE FACE OF THE PANELS.
GROUT TO BE USED SHALL BE NON-SHRINK AND HAVE A 28 DAY CHARACTERISTIC
STRENGTH OF 60MPa. DETAILS OF THE PROPOSED GROUT USED TO BE SUBMITTED
TO THE SUPERINTENDENT FOR APPROVAL.
WHERE REQUIRED, SITE WELDING OF METAL FIXINGS MAY BE DONE WITHOUT
REMOVING THE GALVANISING PROVIDED THE CORRECT TYPE OF CELLULOSE
ELECTRODE TO AS1553 IS USED AFTER WELDING. COLD GALVANISE AFFECTED AREA.
REFER ALSO TO THE SPECIFICATION.
HIGH STRENGTH PLASTIC PACKERS TO BE USED FOR LEVELLING UNDER SUPPORT
POINTS OF LOAD BEARING PRECAST MAY BE LEFT PERMANENT PROVIDED THEY ARE
CENTRALLY LOCATED WITHIN THE EDGES OF THE PANELS, HAVE A MINIMUM OF
50mm GROUT COVER AND ENSURE BEARING PRESSURE LESS THAN 7MPa. REMOVE
PACKERS TO ALL COLUMNS.
PACKERS USED BETWEEN NON-LOADBEARING PANELS SHALL BE REMOVED IMMEDIATELY
FOLLOWING THE INSTALLATION OF THE UNITS UOS. WHERE PACKERS ARE USED TO
TAKE UP TOLERANCES, THE THICKNESS SHALL BE SUCH THAT NO MORE THAN 3
PACKERS REQUIRED PRIOR TO ADDITIONAL FLOOR AND WALL LOAD BEING APPLIED
TO THE PANEL. THE BED OF GROUT AT THE BASE MUST HAVE ACHIEVED FULL STRENGTH.
ALL LOAD BEARING PRECAST UNITS SHALL BE FULL GROUTED FOR THE FULL EXTENT
OF THEIR BEARING AREA UNLESS OTHERWISE NOTED OR APPROVED BY THE ENGINEER.
FIREPROOF CONNECTIONS AND JOINTS AS REQUIRED AND AS SET OUT ON THE
ARCHITECTURAL DRAWINGS TO GIVE THE REQUIRED FIRE RATINGS.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S002
SHEET 2
GENERAL NOTES
SS
CDG
-
-
JAN 19
STRUCTURAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
D
REFER PLAN FOR SETDOWN
LOCATION AND DEPTH
3D1
1½
D M
AX.
D
TYPICAL SLAB SETDOWN
250
1N12 CONTINUOUS TIED TO
UNDERSIDE OF REINF.
D
250
SLAB EDGE THICKENING (ET1)
6 WIDE x (40+D/2) DEEP SAWCUT
MADE 18-30 HOURS AFTER POURING
SLAB. SEAL WITH APPROVED SEALANT
STOP REINF. EACH SIDE OF
SAWCUT POSITION. ENSURE
ACCURATE POSITIONING OF BOTH
REINF. AND SAWCUT PERMANENT
MARKERS ON FORMWORK OF BY
OTHER APPROVED MEANS.
DD/2 4D
SAWCUT JOINT (SCJ)
TYP.
75
S25 MIN.
= GREATER THAN S1 OR S2 PLUS 25mm
MINIMUM OVERLAP
S2
NOTES:
1. REFER ALSO TO STANDARD DETAILS
TENSION LAP SPLICE CONVENTIONAL
FABRIC STANDARD DETAIL
℄
EDGE OF SLAB
NON-SHRINK GROUT INFILL
POURED AFTER MAIN SLAB.
1N16 TIED TO UNDERSIDE OF
SLAB REINFORCEMENT TYPICAL
'EJ' DETAIL APPLIES AROUND COLUMN
300 COG TYPICAL
EXPANSION JOINT (EJ) DETAIL WITH NO JOINT
N20x2000 LONG
RE-ENTRANT BAR IN SLAB
AT ALL RE-ENTRANT CORNERS
SCALE 1:20 SCALE 1:20 SCALE 1:20
SCALE 1:20
SCALE 1:20
PERIMETER DISTANCE TO ALLOW
FOR COLUMN BASE PLATE
1
1
600
℄
EDGE OF SLAB
MASS CONCRETE INFILL
POURED AFTER MAIN SLAB.
1N16 TIED TO UNDERSIDE OF
SLAB REINFORCEMENT TYPICAL
'EJ' DETAIL APPLIES AROUND COLUMN
REFER PLANS FOR JOINT TYPE.
300 COG TYPICAL
EXPANSION JOINT (EJ) AT JOINT LOCATIONS SCALE 1:20
X
MIN.
150
MAX.
450
FULLY SCABBLED JOINT
N12-300
N12-300 CONT.
(300 LAP)
FULLY SCABBLED JOINT
N12-300
X
MAX.
450
MIN.
150
N12-300 CONT.
(300 LAP)
X
MAX.
200
MIN.
150 300
900 MAX. CRS
FULLY SCABBLED JOINT
N12-300
TYPICAL PLINTH/KERB DETAILSSCALE 1:20
a) WHERE X ≤ 150mmb) WHERE X ≤ 1200mm c) WHERE X > 1200mm
NOTES:
1. ADD FURTHER ROWS BARS AT 900 MAX. CRS.
FOR WIDER PLINTHS
GALV. EDGE FORM
TO SERVICES CONTRACTORS
REQUIREMENTS
GALV. EDGE FORM
TO SERVICES CONTRACTORS
REQUIREMENTS
EXPANSION JOINT (EJ) AT INTERNAL COLUMN
℄
1N16 TIED TO UNDERSIDE OF SLAB
REINFORCEMENT TYPICAL
300
300
INFILL CONCRETE POURED
AFTER MAIN SLAB
REFER PLANS FOR JOINT TYPE.SHS COLUMN
COLUMN BASE PLATE
DISTANCE TO ALLOW FOR
SCALE 1:20
6x25 FORMED OR SAWCUT GROOVE
SEALED WITH APPROVED SEALANT.
SAWCUT TO BE MADE 18-30 HOURS
AFTER POURING SLAB.
STOP REINF. EACH
SIDE OF JOINT.
N/A FOR FIBRE REINF.
6mm GALVANISED DANLEY DIAMOND
DOWEL AT 450 MAX. CRS.
DD/2 4D
DOWELLED CONSTRUCTION JOINT (DCJ)
TYP.
75
6
SCALE 1:20
D
350
SLAB THICKENING (ST1) SCALE 1:20
1
1400
200
600 L
AP
'L' BARS TO MATCH
WALL VERTICAL REINF.
AFS WALL
SLAB REINF.
REFER TO PLAN
WPM
SLAB AS PER PLAN
12 BASE PLATE
20 NOMINAL GROUT
2M20 'U' BOLTS
(GALVANISED) CAST IN.
UNO
MIN.
250
TYPICAL COLUMN BASE PLATE DETAIL
COLUMN REFER
TO PLAN & SCHEDULE
REFER EXPANSION JOINT
DETAIL ON DRG. S005 FOR
BLOCKOUT AND INFILL DETAILS
1
1
UNO
250
DAMP PROOF
MEMBRANE
D
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 20
AVOPILING HEADQUARTERS
18-151
S005
SHEET 1
STANDARD DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
GROUT
20 N
OMINAL
NON-METALLIC LEVELLING SHIMS.
FULLY GROUT PANEL/FOOTING
INTERFACE ON COMPLETION OF
LEVEL AND PLUMBED
THIS PORTION OF SLAB TO BE POURED
AFTER TILT-UP PANELS ERECTED
PLUMBED AND GROUTED
PANEL REINF. REFER
SCHEDULE ON DRG. S010
TYPICAL INTERNAL PANEL TO FOOTING DETAIL
100
DPM
250 U
NO.
NOMINAL NON
METALLIC SHIMS
NOMINAL NON
METALLIC SHIMS
℄
℄
FOOTING
FOOTING
℄FOOTING
℄FOOTING
TYPICAL PANEL LOCATING PFC & SHIM SETOUT
200
200 200
180PFC (150 PANEL), 150PFC (125 PANEL)
LOCATING PFC. FIX TO FOOTING WITH
1-M16 HILTI HIT HY150 CHEMICAL ANCHOR
OR APPROVED EQUIVALENT
180PFC (150 PANEL), 150PFC (125 PANEL)
LOCATING PFC. FIX TO FOOTING WITH
2-M16 HILTI HIT HY150 CHEMICAL ANCHORS
OR APPROVED EQUIVALENT
200
400
GROUT
20 N
OMINAL
250 U
NO.
H.D. GALVANISED LOCATING PFC AT EACH
PANEL JOINT AND PANEL ENDS. REFER
TYPICAL PANEL LOCATING PFC AND SHIM
SETOUT DETAIL
NON-METALLIC LEVELLING SHIMS.
FULLY GROUT PANEL/FOOTING
INTERFACE ON COMPLETION OF
LEVEL AND PLUMBED
12mm REIDBAR x 800 LONG AT 2000
MAX. CRS. AND AT 200 MAX. FROM
ENDS CENTRAL TO SLAB
(NOT LESS THAN 3 PER PANEL)
12mm REIDBAR INSERT
PANEL REINF. REFER
SCHEDULE ON DRG. S100
TYPICAL EXTERNAL BOUNDARY PANEL TO FOOTING DETAIL
1000 DELAYED POUR STRIP
AFTER TILT-UP PANELS ERECTED PLUMBED AND GROUTED
THIS PORTION OF SLAB TO BE POURED
425 MIN. LAP
SLAB MESH TO BE CONTINUOUS
ACROSS JOINT. MATCH
DELAYED POUR STRIP REINFT.
WITH MAIN SLAB REINFT.
DPM
150 x 8 PL. FLAT. 6 CFW
TO PFC
150 x 8 PL. FLAT. 6 CFW TO PFC
GROUT
20 N
OMINAL
250 U
NO.
TOP OF FOOTING LEVEL CAN
BE UP TO SSL -500mm WHERE
DOWN PIPE OCCURS (IF REQUIRED)
TO AVOID CLASH
H.D. GALVANISED LOCATING PFC AT EACH
PANEL JOINT AND PANEL ENDS. REFER
TYPICAL PANEL LOCATING PFC AND SHIM
SETOUT DETAIL
NON-METALLIC LEVELLING SHIMS.
FULLY GROUT PANEL/FOOTING
INTERFACE ON COMPLETION OF
LEVEL AND PLUMBED
12mm REIDBAR x 800 LONG AT 2000
MAX. CRS. AND AT 200 MAX. FROM
ENDS CENTRAL TO SLAB
(NOT LESS THAN 3 PER PANEL)
12mm REIDBAR INSERT
PANEL REINF. REFER
SCHEDULE ON DRG. S100
TYPICAL EXTERNAL PANEL TO FOOTING DETAIL
1000 DELAYED POUR STRIP
AFTER TILT-UP PANELS ERECTED PLUMBED AND GROUTED
THIS PORTION OF SLAB TO BE POURED
425 MIN. LAP
SLAB MESH TO BE CONTINUOUS
ACROSS JOINT. MATCH
DELAYED POUR STRIP REINFT.
WITH MAIN SLAB REINFT.
DPM
BOUNDARY
600 TYP.
600 TYP.
300 COG WHERE STRIAGHT
BAR CANNOT BE ACHIEVED
1N12 DIAGONAL BAR
1N12 TRIMMER BAR
EACH SIDE AND TOP
NOTE:
MAINTAIN 50 COVER
TO DOOR PENETRATION
600 T
YP.
600 TYP.
NOTE:
MAINTAIN 50 COVER
TO DOOR PENETRATION
300 COG WHERE STRIAGHT
BAR CANNOT BE ACHIEVED
FROM EDGE
300 MIN.1000 MAX.
1000 M
AX.
1N12 DIAGONAL BAR
AT CORNERS TYP.
TYPICAL TRIMMERS AT DOOR/OPENINGS TYPICAL TRIMMERS AT PANEL PENETRATION
REFER WALL SCHEDULE ON
DRAWING S400
NOTE:
1. N12 PERIMETER BAR CENTRAL. COGGED 300
U.N.O.
2. DETAILS APPLY UNLESS NOTES
OTHERWISE ON MAIN PANEL ELEVATIONS.
TYPICAL PANEL REINFORCEMENT
SILICON SEALANT AND
BACKING ROD EACH FACE
20 GAP15x15 CHAMFER
PANEL THICKNESS
REFER TO SCHEDULE
TYPICAL PANEL JOINT DETAIL
EDGE BARS AS PER
TYPICAL PANEL REINF.
WHERE E
DGE D
ISTANCE <
500mm
N10
-200 L
IGS
SLAB AT DOOR OPENING
300 MIN.
PROVIDE ADDITIONAL 3-N16 AT
100 CTS. AT INCOMING ROOF
MEMBER HEIGHT
REFER TYPICAL PANEL
JOINT DETAIL
TYPICAL PANEL TO COLUMN CONNECTION DETAIL
1-M20 FERRULE WITH
N12 x 300 LONG CROSS BAR
200200
1-M20 BOLT IN 26 DIA.
HOLE
12 PLATE FIXING CLEAT.
FSBW TO COLUMN
COLUMN. REFER PLAN
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S006
SHEET 2
STANDARD DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
AT JOINT
PANEL
PANEL
6/M20 GALV. BOLTS IN
50 WIDE HORIZONTALLY
SLOTTED HOLES
(M20 GRADE 4.6S
THROUGH PANEL WHEN
FIXING BOTH SIDES)
3/M20 CAST IN FERRULES
AT 200 VERT. CRS. TO
EACH PANEL
EX 16 PL 60 EDGE DISTANCE
MIN. TYP. TO SLOTTED HOLE
SUPPORTING CLEAT
FOR INCOMING BEAM
6/M20 CAST IN FERRULES
(200 MIN EDGE DISTANCE
ALL DIRECTIONS UNO)
(M20 GRADE 4.6S
THROUGH PANEL WHEN
FIXING BOTH SIDES)
N12 CROSS BAR 1200
LONG (COGGED AT
CORNERS WHERE
APPLICABLE)
200
200
NOM.
20
200200
SUPPORTING CLEAT DETAILS FOR INCOMING BEAMS
(BEAMS 360UB-460UB)
TYPICAL PANEL TO PANEL CONNECTION
4/M20 GALV. BOLTS
IN 50 SLOTTED HOLES
SLOTTED VERT. ONE
SIDE , HORIZ. OTHER
SIDE OF JOINT
2/M20 CAST IN FERRULES
AT 200 VERT. CRS. TO
EACH PANEL
450x300x16 PL
200
NOM.
20
150150
150
75
6020020 UNO
26x50 LONG HORIZONTAL
SLOTTED HOLES
GUSSET
10 PLATE AT MID DEPTH
16 PLATE
26x50 WIDE VERTICAL
SLOTTED HOLES
2M20 FERRULES AT
200 VERTICAL CRS
N12x1200 LONG CROSS
BAR THROUGH BOTH
FERRULES TYPICAL
4M20 FERRULES AT
200 VERTICAL CRS
TYPICAL CORNER PANEL CONNECTION
PLAN DETAIL
200
20 U
NO
4M20 FERRULES AT
200 VERTICAL CRS
N12x300 LONG CROSS
BAR THROUGH BOTH
FERRULES TYP.
50 DIA. HOLES FOR
M16 BOLTS WITH
WELDED 6mm PLATE
WASHERS
10 PLATE
SINGLE LINE OF
BOLTS 2M20 FERRULES AT
200 VERTICAL CRS.
26x50 LONG HORIZONTAL
SLOTTED HOLE. WASHERS
TO SUIT.
TYPICAL CORNER BRACE/PANEL CONNECTION
AT JOINT
SUPPORTING CLEAT DETAILS FOR INCOMING BEAMS
(BEAMS 310UB OR SMALLER)
PANEL
4/M20 GALV. BOLTS
IN 50 WIDE HORIZONTALLY
SLOTTED
HOLES. TO EACH PANEL
(M20 GRADE 4.6S
THRU PANEL WHEN
FIXING BOTH SIDES)
2/M20 CAST IN
FERRULES
AT 200 VERT. CRS TO
EACH PANEL
EX 16 PL, 60 EDGE DIST
MIN TYP. TO SLOTTED
HOLES
SUPPORTING CLEAT
FOR INCOMING BEAM
20 NOM.
200200200
50 DIAMETER HOLES TO
20 PLATE WITH SITE
WELDED 6mm PLATE
WASHER
60
60
60 60
50 DIAMETER HOLES TO
20 PLATE WITH SITE
WELDED 6mm PLATE
WASHER
60
60
6060
60
60
60
6060
PANEL
6/M20 GALV.
BOLTS
PANEL
4/M20 GALV. BOLTS
(M20 GRADE 4.6S
THROUGH PANEL WHEN
FIXING BOTH SIDES)
EX 16 PL
SUPPORTING CLEAT
FOR INCOMING BEAM
4/M20 CAST IN FERRULES
(200 MIN EDGE DISTANCE
ALL DIRECTIONS UNO)
(M20 GRADE 4.6S THROUGH
PANEL WHEN FIXING BOTH
SIDES)
N12 CROSS BAR 1200
LONG (COGGED AT
CORNERS WHERE
APPLICABLE)
EX 16 PL
300
200
300
200
300
200
200
200
SUPPORTING CLEAT
FOR INCOMING BEAM
B
B
A
A
SECTION B-B
SECTION A-A
A
A
B
B
20 U
NO
TYPICAL BRACING/PANEL CONNECTION
200
200
50 DIA. HOLES FOR
M20 BOLTS WITH
WELDED 6mm PLATE
WASHERS
2M20 FERRULES AT
200 VERTICAL CRS.
26x50 LONG HORIZONTAL
SLOTTED HOLE. WASHERS
TO SUIT.
REFER PLAN IF
BRACE IS APPLICABLE
10 PLATE AT MID
HEIGHT OF 16 PLATE
16 PLATE x 300 DEEP
N12x300 LONG TIE RODS TYP.
TYPICAL BRACING/PANEL CONNECTION
50 DIA. HOLES FOR
M20 BOLTS WITH
WELDED 6mm PLATE
WASHERS
2M20 FERRULES AT
200 VERTICAL CRS.
26x50 LONG HORIZONTAL
SLOTTED HOLE. WASHERS
TO SUIT.
REFER PLAN IF
BRACE IS APPLICABLE
10 PLATE AT MID
HEIGHT OF 16 PLATE
16 PLATE
N12x300 LONG TIE RODS TYP.
200
200
20 U
NO
TYPICAL BEAM/PANEL CONNECTION
200
200
50 DIA. HOLES WITH
WELDED 6mm PLATE
WASHERS
2M20 FERRULES AT
200 VERTICAL CRS.
26x50 LONG HORIZONTAL
SLOTTED HOLE. WASHERS
TO SUIT.
10 PLATE BRACING CLEAT
F.S.B.W TO PLATE TYP.
FERRULES WITH
N12x300 LONG
AS PER BEAM
BRACKET DETAILS
DISPLACEMENT U
NO
50 M
AX.
TYPICAL BEAM/PANEL CONNECTION
26 DIA. HOLES
CONNECTING PLATE REFER
BEAM BRACKET DETAILS
FERRULES WITH
N12x300 LONG
AS PER BEAM
BRACKET DETAILS
200
200
SCALE 1:10 SCALE 1:10 SCALE 1:10 SCALE 1:10
REFER PLAN IF
BRACE IS APPLICABLE
REFER PLAN IF
BRACE IS APPLICABLE
10 PLATE BRACING CLEAT
F.S.B.W TO PLATE TYP.
NOTE
ALL PANELS TO HAVE A MINIMUM OF 2
PLATE CONNECTIONS AT ROOF LEVEL
150 x 12 END PL.
2-M20 HILTI HIT HY150
CHEMICAL ANCHORS OR
APPROVED EQUIVALENT
PROVIDE PL. PACKERS TO
SUIT
10 PL. CLEAT
2-M20 8.8/S BOLTS
REFER TYPICAL
SUPPORTING CLEAT
DETAILS FOR
INCOMING BEAMS
PANEL JOINT
20 NOM.
150 150
TYPICAL WALL BEAM CONNECTION DETAIL
AT JOINT
PANELPANEL
WALL BEAM
TYPICAL WALL BEAM END CONNECTION
DETAIL TO PANEL
TYPICAL WALL BEAM END CONNECTION
DETAIL TO STEELWORK
A1S007
2-M20 HILTI HIT HY150
CHEMICAL ANCHORS OR
APPROVED EQUIVALENT
125 x 75 x 10 EA
x 200 LONG
2-M20 8.8/S BOLTS
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 10
AVOPILING HEADQUARTERS
18-151
S007
SHEET 3
STANDARD DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
VIEWS007 1 : 10
A1
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
TYPICAL PURLIN LAP DETAILSSCALE 1:10
900 LAP UNO
8 PLATE CLEAT
2M12 PURLIN BOLTS
PURLIN. REFER TO
PLAN & SCHEDULE
FOR SIZES
BEAM
END PLATE
FSBW
CLEAT
FACE O
F S
UPPORTING M
EMBER
2 BOLT - SECTION VIEW
2 BOLT - PLAN VIEW
MEMBER No. OF BOLTS CLEAT THICKNESS END PL. THICKNESS
TYPICAL ROOF PENETRATION TRIMMER DETAIL
SCALE 1:10
ROOF PURLINS
C10019 TRIMMER
PURLINS
LBI GENERAL PURPOSE
BRACKET 2M12 4.6/S
END. TYPICAL
C10019 TRIMMER
PURLINS
Z15015 TRIMMER
PURLINS
(MINOR PENETRATION ONLY)
R6 HOOKED THROUGH
PURLIN AT MID-DEPTH
AND LOOPED AROUND
ANGLE BRACE AT
EVERY 2nd PURLIN
SAG ROD TO PASS
THROUGH PURLIN
AT MID-DEPTH
ROOF BRACING
REFER ROOF PLAN
R12 SAG ROD HOOKED ONE
END AND THREADED FOR
M12 NUT OTHER END
ROOF PURLIN REFER
ROOF PLAN
TYPICAL SAG ROD DETAILSSCALE 1:10
PROVIDE SAG RODS TO ALL ANGLE ROOF BRACING
MEMBERS (REFER ROOF PLAN)
8 CFW
TYPICAL SHS/RHS/CHS CONNECTION DETAILS
PURLIN CLEATS AND BOLTING
TO PURLIN MANUFACTURERS
RECOMMENDED DETAILS UNO.
WHERE ANGLE CANNOT BE CONCEALED
IN THE CEILING ROTATE VERTICAL LEG
TO SUIT
'RA' RAKING ANGLE TYPICAL WITH
1M12/20 HSL-3 ANCHOR OR APPROVED
EQUIVALENT AT EACH PURLIN
LOCATION AND WITHIN 150mm FROM
EACH END OF ANGLE.
SUPPLY RAKING ANGLE IN LENGTHS
SUITABLE FOR EASY HANDLING ON
SITE, BUT NO LENGTH TO BE LESS
THAN PURLIN SPACING PLUS 200mm
NOMINAL CEILING LINE
TYPICAL RAKING ANGLE CONNECTION
EQ
EQ
75 SHS
100 SHS
150 SHS
100x50 RHS
114 CHS
140 CHS
2-M20 8.8/S
2-M20 8.8/S
4-M20 8.8/S
2-M20 8.8/S
2-M20 8.8/S
4-M20 8.8/S
10
10
10
10
10
10
10
12
12
12
12
12
12 PL. CAP
4-M20 8.8/S BOLTS
10 PL. STIFFENER
EACH SIDE
NOTE:
1. BEAM MAY ALSO BE ON SLOPE, IN THIS CASE STIFFENERS
TO REMAIN VERTICAL.
2. COLUMN MAY BE UB/UC SECTION ALSO.
TYPICAL BEAM TO COLUMN DETAIL
COLUMN UNDER
TOP OF RAFTER
FACE O
F C
OLUMN
DIM 'X'
DIM 'X'
2M12 BOLTS
PURLIN CLEAT
2M12 BOLTS
GIRT CLEAT
PURLIN/GIRT CLEAT SCHEDULE
DIM 'X' PURLIN/GIRT CLEAT0-10
11-40
41-150
151-500
501-800
8 PLATE
60x10 PLATE
75x10 PLATE
75x8 EA
90x10 EA
NOTE: REER ARCHITECT'S DETAILS TO ENSURE
DEPTH OF BOX GUTTERS ARE ACHIEVED
TYPICAL PURLIN CLEAT DETAILS
REFER SCHEDULE No. 1
FOR CLEAT SIZES
COPE TOP & BTM FLANGE
AS REQUIRED
FACE OF COLUMN, WEB
OR FLANGE
NOTE:
PROVIDE 10mm BACKING PLATE
WHEN CONNECTING TO SHS COLUMN
REFER SCHEDULE No. 1
FOR BEAM SIZE AND
BOLT DETAILS
BEAM/COLUMN CONNECTION SCHEDULE No. 1
BEAM SIZE CLEAT PLATE No. OF BOLTS150,200,250 PFC
300 PFC
310 UB & UC
360 UB
10mm
10mm
10mm
10mm
2-M20 8.8/S
3-M20 8.8/S
3-M20 8.8/S
3-M20 8.8/S
TYPICAL BEAM/COLUMN CONNECTION DETAIL
NOTE:
6mm CFW BOTH SIDES FOR 10 PLATE
REFER SCHEDULE No. 1
FOR CLEAT SIZES
COPE TOP FLANGE
AS REQUIRED
REFER SCHEDULE No. 1
FOR BEAM SIZE AND
BOLT DETAILS
COPE BTM FLANGE
AS REQUIRED
BEAM SIZE VARIES
TYPICAL BEAM FLYBRACE DETAILSSCALE 1:10
BEAM. WHERE
APPLICABLE
8 PLATE CLEAT
2M12 PURLIN BOLTS
PURLIN. REFER TO
PLAN & SCHEDULE
FOR SIZES
50x50x5EA BRACE
1M12 BOLT TO PURLIN
6 PLATE CLEAT
6 CFW
1M12 BOLT
END PLATE
FSBW
CLEAT
FACE O
F S
UPPORTING M
EMBER
4 BOLT - SECTION VIEW
4 BOLT - PLAN VIEW
8 CFW
900 LAP UNO
8 PLATE CLEAT
2M12 PURLIN BOLTS
TYPICAL PURLIN LAP DETAILSSCALE 1:10
TYPICAL PURLIN LAP DETAILSSCALE 1:10
8 PLATE CLEAT
2M12 PURLIN BOLTS
6 PLATE CLEAT
1M12 PURLIN BOLTS TYP.
50x50x5EA BRACE
1M12 BOLT TO PURLIN
MEMBER
75x75 SHS
125x125 SHS
A
250
310
BOLTS
2-M20 U BOLTS
2-M20 U BOLTS
X
A
XA
BASE PLATE
THICKNESS "T"
6mm CFW
X
170
220
T
12
16
TYPICAL SHS BASE PLATE DETAILS
L
3d
d
'B' sq
E/2
Et
GRADE 4.6 BOLT
OR M.S. ROD WITH
THREADED END
H.D BOLTS
2/W6 LIGS TO
H.D. BOLTS
ACCURATELY SET
OUT H.D BOLTS
6
6
TYPICAL HOLDING DOWN BOLT DETAIL
BOLT DIA.
'd'
16
20
24
EMBEDMENT
(MIN.) 'E'
200
250
300
LENGTH 'L'
320
370
450
SQUARE PLATE
'B'
65
75
100
't'
10
12
16
TYPICAL HOLDING DOWN BOLT DETAILSCALE 1:10
1. ALL HOLDING DOWN BOLTS TO BE HOT DIP GALVANISED.
2. ALL HOLDING DOWN BOLTS TO BE SECURELY FIXED AND HELD
IN POSITION DURING CONCRETE PLACEMENT TO THE
ARCHITECT'S APPROVAL.
3. SURVEY LOCATION OF ALL HOLDING BOLTS PRIOR TO PLACING
CONCRETE.
GROUT INFILL ON
COMPLETION
70
550
300
40
200
65
TYPICAL SC1 BASE PLATE DETAILS
20mm BASE PLATE
THICKNESS
8mm CFW
6-M24 HD BOLTS.
REFER DETAIL
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 10
AVOPILING HEADQUARTERS
18-151
S008
SHEET 4
STANDARD DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
UP
A
1
2
3
4
5
B C D E F G H I
150
SCJSCJ SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ100
B O U N D A R Y
B O U N D A R Y
PF3
PF3
PF2
PF2
PF2
PF1
PF1PF1 PF1 PF1 PF1
PF4
PF4
PF4
PF5
PF3PF3
SF2
SF1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
DF1
DF1DF1
DF1
DF1
DF1
DF1
DF1
SF2SF2SF2SF2
STEP
STEP
STEP
STEP
PJ PJPJ PJ PJ PJ PJ
PJ
PJPJPJPJPJPJ
PJ
PJ
PJPJ
PJ
PJ
PJ
PF6 PF6SC2
SC2
PW3PW3
PW3 PW2 PW2 PW2 PW2 PW2
PW3
PW3
PW3 PW3 PW3
PW4
PW4
PW4
PW1
PW1
PW2
PW3 PW3PW3
PW3PW3
S.1S250
S.2S250
S.5S351
SC3
SC3
PF7
SC3
SC3
PF7
PF7
SC3
PF7
BR2
REFER SHEET S201 FOR
CRANE MAINTENANCE
PLATFORM LAYOUT
PLAN AND DETAILS
PF4 PW3PJ
PF4PJ
PF4PJ
PW3 PW3
PJ PJ PJ PJ PJ
PW2PW2PW2PW2PW2
LEGEND
DENOTES SLAB THICKNESSXXX
DENOTES 1000mm WIDE DELAYED POUR STRIP. UNO
STEP DENOTES SLAB STEP
DENOTES SAW CUT JOINTSCJ
PWX DENOTES PRECAST WALL TYPE. REFER
DRAWING S041 FOR SPECIFICATIONS.
RE DENOTES 2-N12x1200 LONG RE-ENTERANT BARS
TO ALL INTERNAL SLAB CORNERS
DENOTES 40mm WET AREA SETDOWN
DENOTES DOWELLED CONSTRUCTION
JOINT
DCJ
NOTES:
1. FOR GENERAL NOTES REFER TO DRAWINGS S001 AND S002.
2. REFER ARCHITECTURAL DRAWINGS FOR SETOUT.
3. OFFICE SLAB ON GROUND TO BE 100mm THICK, SL72 MESH, 30 TOP COVER.
4. WORKSHOP SLAB ON GROUND TO BE 150mm THICK, SL82, 30 TOP COVER.
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S101
PART PLAN 1
GROUND LEVEL GENERAL ARRANGEMENT
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 100
GROUND LEVEL - PART PLAN 1
FOUNDATION SCHEDULE
MARK Description
REINFORCEMENT
COMMENTSBOTTOM TOP
PF1 1900 SQ x 400 D N16-200 EW N16-200 EW
PF2 1500 SQ x 400 D 2 LAYERS SL72 MESH -
PF3 1300 SQ x 400 D 2 LAYERS SL72 MESH -
PF4 900 SQ x 400 D 1 LAYER SL72 MESH -
PF5 600 x 2000 x 400 D 2 LAYERS SL72 MESH -
PF6 1250SQ x 400D 1 LAYER SL72 MESH -
PF7 700 SQ x 400 D 1 LAYER SL72 MESH -
SF1 1000W x 350D
SF2 1500W x 400D N12-200 EW N12-200 EW
STRUCTURAL COLUMN SCHEDULE
MARK SIZE COMMENTS
DF1 180 PFC SLIDING DOOR FRAME
SC1 460 UB 67.1 FLYBRACE AT 1/4 POINTS
SC2 125 x 125 x 5.0SHS
SC3 75 x 75 x 4.0SHS
WALL SCHEDULE
MARK SIZE COMMENTS
PW1 230mm THICK CONCRETE PANEL SL82 MESH EF
PW2 175mm THICK CONCRETE PANEL SL92 MESH CENTRAL
PW3 150mm THICK CONCRETE PANEL SL82 MESH CENTRAL
PW4 125mm THICK CONCRETE PANEL SL72 MESH CENTRAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
1
2
3
4
5
I J K L M
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
SCJ
PF1 PF1 PF1 PF1 PF1
PF2
PF2
PF2
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
150
PJ PJ PJPJ
PJ
PJ
PJ
PJ
PJPJPJPJPJ
PJ
PF4
PW2 PW2 PW2 PW2
PW2
PW3
PW3
PW3
PW3
PW3PW3PW3
PW3
REFER SHEET S201 FOR
CRANE MAINTENANCE
PLATFORM LAYOUT
PLAN AND DETAILS
SC3
SC3
BR2
BR2
BR2
PJPJPJ
PW2 PW2 PW2 PW2PJ
PW3 PF4PJPJ
PF4PW3PJ
PF4PW3
LEGEND
DENOTES SLAB THICKNESSXXX
DENOTES 1000mm WIDE DELAYED POUR STRIP. UNO
STEP DENOTES SLAB STEP
DENOTES SAW CUT JOINTSCJ
PWX DENOTES PRECAST WALL TYPE. REFER
DRAWING S041 FOR SPECIFICATIONS.
RE DENOTES 2-N12x1200 LONG RE-ENTERANT BARS
TO ALL INTERNAL SLAB CORNERS
DENOTES 40mm WET AREA SETDOWN
DENOTES DOWELLED CONSTRUCTION
JOINT
DCJ
NOTES:
1. FOR GENERAL NOTES REFER TO DRAWINGS S001 AND S002.
2. REFER ARCHITECTURAL DRAWINGS FOR SETOUT.
3. OFFICE SLAB ON GROUND TO BE 100mm THICK, SL72 MESH, 30 TOP COVER.
4. WORKSHOP SLAB ON GROUND TO BE 150mm THICK, SL82, 30 TOP COVER.
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S102
PART PLAN 2
GROUND LEVEL GENERAL ARRANGEMENT
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 100
GROUND LEVEL GENERAL ARRANGEMENT
FOUNDATION SCHEDULE
MARK Description
REINFORCEMENT
COMMENTSBOTTOM TOP
PF1 1900 SQ x 400 D N16-200 EW N16-200 EW
PF2 1500 SQ x 400 D 2 LAYERS SL72 MESH -
PF3 1300 SQ x 400 D 2 LAYERS SL72 MESH -
PF4 900 SQ x 400 D 1 LAYER SL72 MESH -
PF5 600 x 2000 x 400 D 2 LAYERS SL72 MESH -
PF6 1250SQ x 400D 1 LAYER SL72 MESH -
PF7 700 SQ x 400 D 1 LAYER SL72 MESH -
SF1 1000W x 350D
SF2 1500W x 400D N12-200 EW N12-200 EW
STRUCTURAL COLUMN SCHEDULE
MARK SIZE COMMENTS
DF1 180 PFC SLIDING DOOR FRAME
SC1 460 UB 67.1 FLYBRACE AT 1/4 POINTS
SC2 125 x 125 x 5.0SHS
SC3 75 x 75 x 4.0SHS
WALL SCHEDULE
MARK SIZE COMMENTS
PW1 230mm THICK CONCRETE PANEL SL82 MESH EF
PW2 175mm THICK CONCRETE PANEL SL92 MESH CENTRAL
PW3 150mm THICK CONCRETE PANEL SL82 MESH CENTRAL
PW4 125mm THICK CONCRETE PANEL SL72 MESH CENTRAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
A
1
2
3
4
B C D
RB1
RB1
BR1 BR1
RA1
RA1
BR1BR1
BR1 BR1 BR
1 BR1
ST1ST1ST1
P1
HATCHING DENOTES
BOX GUTTER
S.1S250
S.2S250
PJ PJ PJ
PJ
PJ
PJPJ
PJ
PJ
PJ
S.4S350
A
1
2
3
4
B C D
STEP
200
KINGFLOR
PROP LINE
PROP LINE
PROP LINE
PROP LINE
FB1
N16-300
SC2 UNDER
SC2 UNDER
S.1S250
S.2S250
FA1
FA1
N16-250
DOWEL BARS
N16-250
DOWEL BARS
N16-250
DOWEL BARS
N16-250
DOWEL BARS
N16-250
DOWEL BARS
PJ PJ PJ
PJ
PJ
PJ
PJPJ
PJ
PJ
PJ
4000 L
ONG
FB1
SP
SC3 UNDER
SC3 UNDER
FB2
FB2
FB2
FB2
FB2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
OR2
FP1
FP1 MEZZANINE ROOF
STRUCTURE
(SHADED)
SPEED BRACING
(TYP)
FIX FB2 TO PANEL VIA
M12 HILTI HIT-HY270
ANCHORS AT 900 MAX. CTS.
LEGEND
DENOTES SLAB THICKNESSXXX
STEP DENOTES SLAB STEP
RE DENOTES 2-N12x1200 LONG RE-ENTERANT BARS
TO ALL INTERNAL SLAB CORNERS
DENOTES 40mm WET AREA SETDOWN
DENOTES 200 THICK KF57, 1.0BMT CONCRETE SLAB.
SL81 MESH TOP.
2 ROWS OF PROPS PER SPAN.
1. FOR REINFORCEMENT SIZE, SPACING AND DIMENSIONS REFER TO PLAN.
2. ALL BOTTOM BARS TO BE PLACED IN KINGFLOR TRAYS BEFORE MESH
IS LAID AND SECURELY TIED TO SUPPORTING REINFORCEMENT.
3. ALL TOP BARS TO BE PLACED ON TOP, AND TIES TO THE MESH.
4. KINGFLOR PANELS TO HAVE SIDE LAPS FASTENED AT 1800mm
MAXIMUM CENTRES. WITH No. 12 x 20 SELF DRILLING SCREWS.
5. BEFORE PLACING CONCRETE, ENSURE THAT KINGFLOR PANELS ARE
FREE OF DEBRIS AND SUBSTANCES WHICH COULD ADVERSELY AFFECT
STEEL/CONCRETE BOND.
6. CONCRETE TO CONFORM TO THE SPECIFICATION, AND SHALL BE FREE
OF ADMIXTURES CONTAINING CALCIUM CHLORIDE, SALTS OR
SUPERPLASTICIERS.
7. KINGFLOR PANELS TO BE SECURELY FIXED OF HELD DOWN TO
RPEVENT DISPLACEMENT UNDER CONSTRUCTION LOADS OR WIND
UPLIFT PRIOR TO CONCRETING ALL IN ACCORDANCE WITH 'SPECIFYING
FIELDERS - KINGFLOR'
8. MINIMUM BEARING WIDTH OF PANELS ON SUPPORT WALLS AND
BEAMS SHALL BE 50mm (ADJUST TO SUIT DESIGN).
9. PROVIDE 'ALCOR' STRIP OR SIMILAR APPROVED BOND BREAKER TO
ALL MASONRY WALLS UNDER SLAB.
10. USE KINGFLOR PANELS CONTINUOUS LENGTHS OVER A MINIMUM OF
TWO SPANS INTERNALLY UNLESS NOTES OR SHOWN OTHERWISE.
11. NO MASONRY SHALL BE LAID ON THE SLAB WHILST IT IS PROPPED.
KINGFLOR NOTES:
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S200
FIRST FLOOR GENERAL ARRANGEMENT AND OFFICE ROOF
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 100
ROOF FRAMING PLAN
SCALE: 1 : 100
FIRST FLOOR GENERAL ARRANGEMENT
STRUCTURAL STEELWORK SCHEDULE
MARK SIZE COMMENTS
BR1 75 x 5 EA
BR2 65 x 5 EA
CB1 530 UB 92 + 300 PFC CRANE BEAM
DF2 180 PFC SLIDING DOOR FRAME
DH1 150 x 90 x 8UA SLIDING DOOR HEADER
FA1 125 x 8EA
FB1 250 UB 37
FB2 200 PFC
FB3 75 x 4.0 SHS
FP1 C250 15
G1 C150 15 AT 450 MAX. CTS.
J1 C150 15 AT 450 MAX. CTS.
OR1 530 UB 92 CRANE BEAM OUTRIGGER
OR2 150 UC 30
P1 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P2 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P3 C100 12
RA1 150 x 90 x 8UA
RB1 360 UB 44.7
ST1 125 x 5.0 SHS
ST2 150 x 5.0 SHS
ST3 150 x 5.0 SHS
WB1 200 PFC WALL BEAM. REFER TYP. DETAILS ON S007
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
A B C DS.1S250
D
S250
SC3
PF7PF2PF5
FB2
RB1
RB1
RA1
RA1
OR2
OR2
E
S250
1234
S.2S250
RB1
SC2
SF1
PF6PF3
A
S250
B
S250
OR2
OR2
FP1
FP1
C
S250
12
FA1
N16-250 DOWEL BARS
x 500 LONG
SL81 MESH
PW3
FIXED TO PANEL VIA
M16 CHEMICAL ANCHORS
AT 300 CTS. TYP.
3
SC2
19 DIA STUDS AT 300 CTS. TYP.
150 HIGH CENTRAL
10 PLATE CLEAT
3-M20 8.8/S BOLTS
TYP.
50 C
OVER
A
N16-250 DOWEL BARS
x 500 LONG
SL81 MESH
D
FB2
SC3
FB2
10 END PLATE
4-M12 HILTI HIT-HY270
ANCHORS (TYP)
8 PLATE CLEAT
2M12 BOLTS (TYP)
10 CAP PLATE
2-M16 BOLTS
(PER BEAM)
MITRE AND FULLY WELD
BEAMS AT CORNERS
FLOORING TO ARCHITECTS'
SPECIFICATIONS
4
8 PLATE CLEAT
2M12 BOLTS (TYP)
10 PLATE CLEAT
4M12 BOLTS (TYP)
10 PLATE CLEAT
2M12 BOLTS (TYP)
OR2FP1
FP1
20 END PLATE
4-M12 HILTI HIT-HY270
ANCHORS (TYP)
CLADDING TO
ARCH. DETAILS
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S250
FIRST FLOOR LEVEL
SECTIONS AND DETAILS - SHEET 1
SS
CDG
-
-
JAN 19
STRUCTURAL
NOTE:
SITE AND SHOP WELDED STUDS TO BE IN
ACCORDANCE WITH AS1554 (PART 2) WELDING
OF STEEL STRUCTURES AND AS2327 (PART 1)
COMPOSITE CONSTRUCTION CODE SIMPLY
SUPPORTED BEAMS
SECTION 1 : 100S101
S.2SECTION 1 : 100S101
S.1
DETAIL 1 : 20S250
A DETAIL 1 : 20S250
B
DETAIL 1 : 20S250
D DETAIL 1 : 20S250
E
DETAIL 1 : 20S250
C
REV DATE DESCRIPTION DRN CHD
A 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
STEP LADDER UP
PJ1
2
I
SC3
SC3
PF7 PF7
PF7
SC3
SC3
LOWER SC3 COLUMN TO
STRIP FOOTING BELOW
(THIS LOCATION ONLY)
SC1
EXTENT OF CRANE MAINTENANCE
PLATFORM OVER
S.6S251
S.7S251
1
2
I
SC3 UNDER
SC3 UNDER
SC3
SC3
FB2
FB2
FB2
SPEED BRACING
FB2
J2
S.6S251
S.7S251
LEGEND
DENOTES SLAB THICKNESSXXX
STEP DENOTES SLAB STEP
RE DENOTES 2-N12x1200 LONG RE-ENTERANT BARS
TO ALL INTERNAL SLAB CORNERS
DENOTES 40mm WET AREA SETDOWN
DENOTES 200 THICK KF57, 1.0BMT CONCRETE SLAB.
SL81 MESH TOP.
2 ROWS OF PROPS PER SPAN.
I
S.7S251
BR2 BR2
SC3
SC3
FB3
BR2 BR2
FB2FB2FB2
PF7 PF7
12
S.6S251
BR2 BR2
BR2BR2
FB3SC3
PF7SF2
FB2FB2
CB1
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S251
CRANE MAINTENANCE PLATFORM PLANS & DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 50
CRANE PLATFORM FOUNDATION LAYOUTSCALE: 1 : 50
CRANE PLATFORM FRAMING PLAN
STRUCTURAL STEELWORK SCHEDULE
MARK SIZE COMMENTS
BR1 75 x 5 EA
BR2 65 x 5 EA
CB1 530 UB 92 + 300 PFC CRANE BEAM
DF2 180 PFC SLIDING DOOR FRAME
DH1 150 x 90 x 8UA SLIDING DOOR HEADER
FA1 125 x 8EA
FB1 250 UB 37
FB2 200 PFC
FB3 75 x 4.0 SHS
FP1 C250 15
G1 C150 15 AT 450 MAX. CTS.
J1 C150 15 AT 450 MAX. CTS.
OR1 530 UB 92 CRANE BEAM OUTRIGGER
OR2 150 UC 30
P1 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P2 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P3 C100 12
RA1 150 x 90 x 8UA
RB1 360 UB 44.7
ST1 125 x 5.0 SHS
ST2 150 x 5.0 SHS
ST3 150 x 5.0 SHS
WB1 200 PFC WALL BEAM. REFER TYP. DETAILS ON S007
STRUCTURAL COLUMN SCHEDULE
MARK SIZE COMMENTS
DF1 180 PFC SLIDING DOOR FRAME
SC1 460 UB 67.1 FLYBRACE AT 1/4 POINTS
SC2 125 x 125 x 5.0SHS
SC3 75 x 75 x 4.0SHS
SECTION 1 : 50S251
S.6 SECTION 1 : 50S251
S.7
REV DATE DESCRIPTION DRN CHD
A 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
1
2
3
4
5
D E F G H I J K
ST2
ST3
ST3
ST2ST2ST2ST2ST2ST2ST2ST2
BR1BR1
BR1 BR1
BR1 BR1
BR1 BR1BR
1 BR1BR1 BR1BR
1 BR1BR1
BR1BR1 BR1BR
1 BR1BR1 BR1
RA1
RA1
RA1
RA1
RA1
RA1
BR1 BR1
RA1
DF2
DF2DF2
DF2
TR1
TR1
TR1
TR1
TR1
TR1
TR1
TR1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
DF1
OR1
OR1
OR1
OR1
OR1
OR1
OR1
OR1
OR1
OR1
CB1 UNDERCB1 UNDER CB1 UNDER
CB1 UNDERCB1 UNDER CB1 UNDER
FALL
FALL
FALL
P1
S.3
S350
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
FB FB
PJ
PJ PJ PJ PJ PJ PJ PJ PJ PJ
PJ
PJ
PJ
PJPJ
PJPJPJPJ
PJPJPJ
PJ
PJ
PJ
TR2
S.4
S350
S.5
S351
PJPJPJ PJ PJ
PJ PJ PJ PJ PJ PJ PJ PJ PJ
WB1 WB1 WB1WB1WB1WB1WB1WB1WB1
WB1 WB1WB1WB1WB1WB1WB1WB1WB1
PJ
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S300
WORKSHOP ROOF FRAMING PLAN
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 100
ROOF FRAMING PLAN
STRUCTURAL COLUMN SCHEDULE
MARK SIZE COMMENTS
DF1 180 PFC SLIDING DOOR FRAME
SC1 460 UB 67.1 FLYBRACE AT 1/4 POINTS
SC2 125 x 125 x 5.0SHS
SC3 75 x 75 x 4.0SHS
STRUCTURAL STEELWORK SCHEDULE
MARK SIZE COMMENTS
BR1 75 x 5 EA
BR2 65 x 5 EA
CB1 530 UB 92 + 300 PFC CRANE BEAM
DF2 180 PFC SLIDING DOOR FRAME
DH1 150 x 90 x 8UA SLIDING DOOR HEADER
FA1 125 x 8EA
FB1 250 UB 37
FB2 200 PFC
FB3 75 x 4.0 SHS
FP1 C250 15
G1 C150 15 AT 450 MAX. CTS.
J1 C150 15 AT 450 MAX. CTS.
OR1 530 UB 92 CRANE BEAM OUTRIGGER
OR2 150 UC 30
P1 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P2 Z200 15 AT 1200 MAX. CRS. 2 ROWS OF BRIDGING
P3 C100 12
RA1 150 x 90 x 8UA
RB1 360 UB 44.7
ST1 125 x 5.0 SHS
ST2 150 x 5.0 SHS
ST3 150 x 5.0 SHS
WB1 200 PFC WALL BEAM. REFER TYP. DETAILS ON S007
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
12345
1.10m DEEP
1.4m DEEP
1.40m DEEP
EQ 1 EQ 1 EQ 1 EQ 1 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2 EQ 2
X
S350 150 x 100 x 6.0RHS
TOP CHORD
150 x 100 x 6.0RHS
BOTTOM CHORD
100 x 100 x 4.0SHS
INTERNALS
5EQ EQ EQ EQ
CONFIRM WITH A
RCHITECT'S DRG'S
6410
TR2: TOP CHORD : 150PFC ON FLAT
BTM CHORD : 150PFC ON FLAT
VERTICALS : C10012
DIAGONALS : C10012
END VERTS. : 150PFC
16 PL. CLEAT AND 2-M20
BOLTS TOP, BOTTOM AND
MID-HEIGHT. SITE WELD
CLEAT TO CAST-IN PLATE
12 PL. CAST-IN TO PANEL END
WITH 2-N12 x 500 LONG
STRAIGHT ANCHORS BARS
FSBW TO BACK OF PLATE.
TYPICAL EACH CLEAT LOCATION
20 PL SPLICE PLATES
4-M20 8.8/TF BOLTS
TOP AND BOTTOM CHORDS AND WEBS
10 PL STIFFENERS EACH SIDE OF
TRUSS CHORD PER MEMBER
SPLICE TO
ARCHITECT'S DETAILS
TR1
TR1
12 PL CLEAT
3-M24 8.8/S BOLTS
TOP AND BOTTOM OF
TRUSS
12 PL TEE
END MEMBER
FASCIA PURLIN 75 PFC
OUTRIGGER 8 PL CLEAT
2-M12 BOTLS EACH SIDE
10 PL STIFFENERS
TYPICAL TRUSS/COLUMN CONNECTION DETAIL TYPICAL TRUSS SPLICE CONNECTION DETAILSCALE 1:20 SCALE 1:20
TYPICAL CRANE BEAM CONNECTION DETAILSCALE 1:20
10 PL. STIFFENERS BOTH
SIDES OF WEB. FSBW TO
FLANGES, 6 CFW TO WEB
250UC72.9. FSBW FLANGES
AND WEB TO COLUMN
10 PL. STIFFENER BOTH
SIDES OF WEB. 6 CFW ALL
ROUND
4-M16 8.8/S BOLTS
6 CFW BOTH SIDES
CRANE RAIL AND FIXINGS
BY CRANE SUPPLIER.
REFER TO CRANE
SUPPLIER FOR DETAILS
10 PL. CLEAT
2-M16 8.8/S BOLTS
250 MAX.
CB1
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S350
TRUSS ELEVATIONS AND DETAILS
SS
CDG
-
-
JAN 19
STRUCTURAL
S300
1 : 100
S.3
TRUSS TR1 ELEVATION SECTION 1 : 20S350
X
S200
1 : 100
S.4
TRUSS TR2 ELEVATION
REV DATE DESCRIPTION DRN CHD
A 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
E F
DF2DF1
DF1
DF1
DF1
A
S351
DF2
G1
PW3
PW3
DF2
DF1
A.1S351
DH1
G1 DOOR GIRTS
DF2
DF1
REFER TO MANUFACTURER'S
DETAILS AND SPECIFICATION
FOR SLIDING DOOR CONNECTION
DH1
DH1 FIXED TO PANEL VIA M12
HILTI HIT-HY170 AT 600 MAX.
CTS. (100mm EDGE DISTANCE)
(TYP)
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S351
ROOF LEVEL
SECTIONS & DETAILS - SHEET 1
SS
CDG
-
-
JAN 19
STRUCTURAL
S101
1 : 100
S.5
TYPICAL SLIDING DOOR ELEVATION DETAIL 1 : 10S351
A SECTION 1 : 10S351
A.1
REV DATE DESCRIPTION DRN CHD
A 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
STEP LADDER UP
ST
AIR
UP
12345
78
6
PJPJ
PJPJ
PJ
PJ PJ PJ PJ
PJ
PJ PJ PJ PJ PJ PJ PJ
PJ
PJ
OVER
PJ
OVER
PJ PJ PJPJ
PJ
PJ PJ PJ PJ
PJ
PJ
FD
FD
UP
S401
3
S401
4
S400
1
S400
2
A
1
2
3
4
5
B C D E F G H I J K L M
S401
5
PJ PJ PJ PJ PJ PJ PJ PJ PJ PJ PJ PJ
PJ
PJ
PJ
PJPJPJPJPJPJPJPJPJPJ
PJ
PJ
PJ
PJ
PJPJ
PJ
PJ
PJ
12345
PW2PW2PW2PW2 PW3 PW3
FGHIJKLM
PW2PW2PW2PW2PW2 PW2 PW2 PW2PW2 PW2 PW2 PW2 PW2 PW2 PW2 PW2
TYPICAL PANEL TO COLUMN
CONNECTION AT MID-HEIGHT
OF PANEL. REFER DETAIL
ON S006 (TYP.)
ABCDE
PW3 PW3
PW2
PW3
PW2
2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
N
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
As indicated
AVOPILING HEADQUARTERS
18-151
S400
SHEET 1
PANEL LAYOUT PLAN & ELEVATIONS
SS
CDG
-
-
JAN 19
STRUCTURAL
SCALE: 1 : 200
PANEL LAYOUT PLAN
ELEVATION 1 : 100S400
2(CONT.)
ELEVATION 1 : 100S251
1
ELEVATION 1 : 100S400
33
WALL SCHEDULE
MARK SIZE COMMENTS
PW1 230mm THICK CONCRETE PANEL SL82 MESH EF
PW2 175mm THICK CONCRETE PANEL SL92 MESH CENTRAL
PW3 150mm THICK CONCRETE PANEL SL82 MESH CENTRAL
PW4 125mm THICK CONCRETE PANEL SL72 MESH CENTRAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
A B C D E F G H I
PW3
PW3PW3
PW3 PW3 PW3 PW3 PW3 PW3
TYP
1000
TYPICAL PANEL TO COLUMN
CONNECTION AT MID-HEIGHT
OF PANEL. REFER DETAIL
ON S006 (TYP.)
PW3PW3PW3 PW3
I J K L M
PW3 PW3 PW3 PW3
TYP
1000
PW3 PW3 PW3
1 2 3 4 5
PW3 PW3
1 2 3 4 5
PW1 PW1
PW2
S.4
S350 2 CLIVE STREET, WEST PERTH WA 6005
Ph: 08 94852921 E: [email protected]
REVPROJECT NUMBER:
GENERAL NOTES: CONTRACTOR TO CHECK ALL DIMENSIONS ON SITE. REFER ANY DISCREPANCIES TO
ARCHITECT FOR A DECISION, PRIOR TO COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING.
DESIGN:
SCALE:
DRAWN:
CHECKED:
APPROVED:
PROJECT:
DRAWING TITLE:
CLIENT:
CONSTRUCTION
DATE:
DRAWING NUMBER:
ARCHITECT:
0
1 : 100
AVOPILING HEADQUARTERS
18-151
S401
SHEET 2
PANEL ELEVATIONS
SS
CDG
-
-
JAN 19
STRUCTURAL
ELEVATION 1 : 100S400
3
ELEVATION 1 : 100S400
44 (CONT.)
ELEVATION 1 : 100S400
4 ELEVATION 1 : 100S400
5
WALL SCHEDULE
MARK SIZE COMMENTS
PW1 230mm THICK CONCRETE PANEL SL82 MESH EF
PW2 175mm THICK CONCRETE PANEL SL92 MESH CENTRAL
PW3 150mm THICK CONCRETE PANEL SL82 MESH CENTRAL
PW4 125mm THICK CONCRETE PANEL SL72 MESH CENTRAL
REV DATE DESCRIPTION DRN CHD
A 01.02.19 PRELIMINARY ISSUE SS CDG
B 08.02.19 ISSUED FOR BUILDING LICENCE SS CDG
0 19.02.19 ISSUED FOR CONSTRUCTION JAG CDG
Document Transmittal
Day 01 08 19
Month 02 02 02
Year 19 19 19
No:
S000 A B 0
S001 A B 0
S002 A B 0
S005 A B 0
S006 A B 0
S007 A B 0
S008 A B 0
S100 A
S101 A B 0
S102 A B 0
First Floor General Arrangement & Office Roof S200 A B 0
S250 A 0
S251 A 0
S300 A B 0
Truss Elevations & Details S350 A 0
Roof Sections & Details S351 A 0
Panel Layout Plan & Elevations - Sheet 1 S400 A B 0
Panel Elevations - Sheet 2 S401 A B 0
Distribution
1 1 1
Issued by:
Date Issued
To:
Attn:
MULDER KAMPMAN
Suite 11w, 817 Beeliar Drive
Cockburn Central, 6164
Jan Kampman
Avopiling HeadquartersProject Title:
18-151
1 of 1
Project No:
Transmittal No.
E
STRUCTURAL
General Notes - Sheet 1
Discipline:
Drawing Register
Cover Sheet & Drawing Index
MULDER KAMPMAN
Site & External Pavement Plan
First Floor Sections & Details
Crane Maintenance Platform
Roof Framing Plan - Workshop
E
A person using FORTH drawings and other data accepts the risk of:
- using the drawings and other data in electronic form without requesting and checking them for accuracy against the original hard copy
version;
- using the drawings or other data for any purpose not agreed to in writing by FORTHChris Gibb
P B C
E
Purpose of Issue: A – Approval; B - Building Permit; C – Construction; F – Forward Works; I – Information; R – Review;
T – For Tender; P - Preliminary
Method of Issue:
C - CD-Rom; E - Email; P - Post/Courier; U - Upload; H - Hardcopy
General Notes - Sheet 2
Standard Details - Sheet 1
Standard Details - Sheet 2
Standard Details - Sheet 4
Standard Details - Sheet 3
Ground Level GA - Part Plan 1
Ground Level GA - Part Plan 2