Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 1
Application Guide for Model 6750 BRTU-93
with Nortel Optera Metro OME6500 DS3 FAD
Revision Author Approval Date
A Victor Afable July 15, 2009
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 2
Table of Contents
1.0 BRTU-93 and DCS Introduction and Preparation --------------------------------------------------------- 3
1.1 Objective ----------------------------------------------------------------------------------------------------- 4
1.2 Description ---------------------------------------------------------------------------------------------------- 4
1.2 Equipment Drawings and Cable Running List ----------------------------------------------------- 5-8
2.0 BRTU-93 Configuration ------------------------------------------------------------------------------------------ 9
3.0 Circuit Access Test --------------------------------------------------------------------------------------------- 14
4.0 REACT TEST RESOURCE Example ---------------------------------------------------------------------- 16
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 3
Section 1.0
BRTU-93 and OME6500 DCS Introduction and Preparation
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 4
1.0 Objective
This document is made for as an application guide for setting up the Model 6750 BRTU and REACT for accessing DS3 circuit using BRTU DS3 FAD Interface card from OME6500 DCS. This document does not cover the overall acceptance/verification and focused only in configurations of Spirent Model 6750 BRTU-93 and REACT to access DS3 circuits via DS3 FAD from OME6500. Additional information may be obtained in the following documents for the purpose of troubleshooting, maintenance, operation requirements, etc.
ATP-6700-085 6750 Acceptance Test Procedure
HKMN-6750-101 6750 Application Drawings.
PN 6750-104 Spirent Digital Command Manual
1.1 Description
This document consist of six sections
Section 1 Introduction and Preparation
Section 2 Model 6750 BRTU
Section 3 Circuit Access Test
Section 4 React Test Resource Example
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 5
1.2 Equipment Drawings
Figure 1-1 Model 6750 BRTU-93 Front View
Figure 1-2 Model 6750 BRTU-93 Rear View
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 6
Note: BRTU-93 Relay Rack Configuration.
Figure 1-3 Typical Rack Elevation (7’ X 1” X 23”) of 6750 BRTU-93
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
l
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
7 3
Filtered Fuse Panel
BRTU-99
Controller Shelf
Heat Baffle is a part of the unit
Heat Baffle is a part of the unit
6” Box
2” SPACING
11’6”
7’
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
l
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
7 3
Filtered Fuse Panel
BRTU-99
Controller Shelf
Heat Baffle is a part of the unit
Heat Baffle is a part of the unit
6” Box
2” SPACING
11’6”
7’
BRTU-93
Controller Shelf
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
l
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
7 3
Filtered Fuse Panel
BRTU-99
Controller Shelf
Heat Baffle is a part of the unit
Heat Baffle is a part of the unit
6” Box
2” SPACING
11’6”
7’
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
l
0
5
1 0
1 5
2 0
2 5
3 0
4 0
5 0
5 5
6 0
6 5
7 0
3 5
4 5
7 3
Filtered Fuse Panel
BRTU-99
Controller Shelf
Heat Baffle is a part of the unit
Heat Baffle is a part of the unit
6” Box
2” SPACING
11’6”
7’
BRTU-93
Controller Shelf
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 7
Note: 1. The BRTU-93 DS3 FAD card will be connected to the OME6500 FAD port. Configuration of the OME6500 DS3 Test Access Port is required.
Figure 1-4 Model 6750 BRTU-93
6705-99
BRTU
J47/J48 – J49/J50
FAC EQPT TB1
TB2-48Vdc
COAX Patch Panel
Ethernet
7121-66P
J46
IP
NETWORK
Ethernet
Nortel
OME6500
Nortel
OME6500
COAX Patch Panel
Ethernet
Ethernet Hub
X-Connect to BRTU-99
DS3 TAP Signal
REACT
REACT and TSC
Control
DS3 DS3
6705-99
BRTU
J47/J48 – J49/J50
FAC EQPT TB1
TB2-48Vdc
COAX Patch Panel
Ethernet
7121-66P
J46
IP
NETWORK
Ethernet
Nortel
OME6500
Nortel
OME6500
COAX Patch Panel
Ethernet
Ethernet Hub
X-Connect to BRTU-99
DS3 TAP Signal
REACT
REACT and TSC
Control
DS3 DS3
BRTU-93
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 8
Cable Running List
Run No.
Cable Type
Code From Equipment
To Equipment
Remarks
EQPT PWR
1 20AWG Red/Black
BRTU-93 Connectors TB1 (Black) TB2 (Red)
-48V Fuse Panel -48VDC Power Supply
COMM/ TEST BUS
2 7121-66P BRTU-93 J46
Ethernet Hub IP Communication to REACT
3 6750-C5 T5500 DS3 TAP Port (FAC)
BRTU FAD card Module J47/J48 DS3 FAD connection
4 6750-C5 T5500 DS3 TAP Port (EQPT)
Brtu FAD Card Module J49/J50 DS3 FAD Connection
Refer to Figure 1.4 for more information
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 9
2.0 Model 6750 BRTU-93 Shelf Configuration: Pull the 6750 SCU card and ENABLE the battery backup by placing the BLUE JUMPER to pin 1 and pin 2 of J1 connector. If the BRTU is equipped with eSCU the battery backup is jumper is J3 enable the battery by placing the BLUE jumper in pin 1 and pin 2.
VBATT EN 1-2
VBATT DIS 2-3 Ba
ttery
1 2 3J3
Set up a VDT (VT100) or a laptop PC for direct connection to the fixed port at 9600 bps, 8 data bits, no parity, and 1 stop bit (9600, 8, N, 1).
Using the 9-pin male/ female Straight Cable, connect the PC to the craft port at the front of the BRTU-93 unit.
2.1.1 Login to the BRTU-93
Enter Command: ACT-USER::SUPER:CTAG::SUPER;
2.1.2 Edit Date and Time
Enter Command: ED-DAT:::CTAG::050906,101500;
YRMMDD,HHMMSS 2.1.3 Edit Site Identifier (SID)
Enter command: ED-SID:HEKIMIAN-6700::CTAG::ILABBRTU;
OLD/CURRENT SID NEW SID
2.1.4 Edit BRTU-93 Equipment Table
Enter Command: ED-ATTR-EQPT:::CTAG::TSC=ON;
Enter Command: ED-ATTR-EQPT:::CTAG::TMO=5000;
2.1.5 Retrieve the Equipment table and response should be as shown below:
Enter command: RTRV-ATTR-EQPT:::CTAG;
Response:
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 10
ILABBRTU01 05-04-12 09:42:39 M CTAG COMPLD "SHELF=99 TSC=ON REPORT=FULL EQLR=0 TMO=5000SECS LEV=REL" "IDLE=TC CYCLETEST=OFF DS3DS3=OFF"
2.1.6 Retrieve the BRTU-93 firmware version
Enter Command: RTRV-VRSN-EQPT:::CTAG; ILABBRTU 06-06-08 15:03:56 M D COMPLD “ DS3-01-01: RA02.20 RA02.20 6700-1472-01 REV E OPT "
" COM-01-23: RA08.60 RB03.10 3500-1275-02 REV D OPT " " SCU-01-24: RH14.10 DH13.62 6700-1652-01 REV B7 OPT " " PSU-01-25: Results shown above are the latest firmware version of the BRTU-93. The eSCU firmware should be at least version 14.10 or higher.
2.1.7 Edit the BRTU-93 IP address as required.
Enter Command: ED-ATTR-IP::J46:CTAG::ADDR= 192.168.1.11; --- IP Address
Enter Command: ED-ATTR-IP::J46:CTAG::MASK=255.255.255.0; --- Subnet Mask
Enter Command: ED-ATTR-IP::J46:CTAG::GATEWAY= 192.168.1.1; --- Gateway
NOTE: Changes to the TCP/IP parameters will take effect only after the BRTU-93 has been rebooted. You need to issue the INIT-SYS:::CTAG::4; command for the TCP/IP changes to take effect.
2.1.8 Retrieve the new IP address after the BRTU boot up and verify that the BRTU now has the new IP
address. Enter Command: RTRV-ATTR-IP:::CTAG;
ILABBRTU01 06-05-26 15:12:07 M F COMPLD /* JID IP ADDRESS SUBNET MASK DEFAULT GATEWAY */ " J46 192.168.1.11 255.255.255.0 192.168.1.1 " /* JID TADR UART ECHO FLOW RAW BROAD SLAVE LOGIN DTR */ " J46 NA NA OFF ON OFF OFF OFF OFF DTR "
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 11
2.2 Edit the BRTU-93 TAU 2.2.1 TAU table set up for the OME6500 DCS: Note: The TID that is used in this example are based on the example drawings shown in figure 1-5.
Refer to REACT administrator for the assigned TID of each DCS. Enter Command: ED-DB-TAU::BUROMESONET:CTAG::TYPE=OME6500,JID=J46,
ADDRESS=172.25.73.140-23,CTYPE=SOCKET,PERSIST=YES; Enter Command: ED-DB-TAU::BUROMESONET:CTAG::UID=OSSDEV,PID=D9934REL3;
BUROMESONET = is the given Test Identifier for the DCS. This should match with the TID in REACT test resource set for that DCS and BRTU-93. TYPE = Access Type enter OME6500 (BRTU uses OME6500 TSC code for Nortel OME6500) JID = J46 as the TSC port ADDRESS= Address of the OME6500 with port 23
The OME6500 has only IP communication links that provide a TL1 interface, through the COLAN RJ45 ports on the access panel. The IP port is 23. (23 is the raw machine interface, 10020 is non-TL1, interactive command prompt.)
CTYPE= Connection Type (SOCKET) UID = OSSDEV (just an example can be case sensitive) PID = D9934REL3 (just an example can be case sensitve)
2.2.2 Retrieve the TAU Table: Enter Command: RTRV-DB-TAU::ALL:CTAG;
ILABBRTU01 07-06-29 08:43:04 M CTAG COMPLD /* TID TYPE REVISION AIDFMT ROUTE */ /* JID ADDRESS CTYPE PERSIST MAXCONN */ /* UID PID LOGIN */ " BUROMESONET OME6500 00.00 000 0 J46 172.25.73.140-23 SOCKET YES 1 OSSDEV D9934REL3 Y "
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 12
2.2.3 TAP Table Set Up
Edit the BRTU TAP table for DS3 testing via DS3 FAD for OME6500 by entering the following commands:
In our example the BRTU DS3 FAD card is inserted in slot 8 of the BRTU-93 shelf. Therefore when setting the TAP for the said DS3 FAD card TPID 4 will be use. See BRTU TPID assignment shown in the next page form more information on TPID assignment per slot of the BRTU-93 Enter Command: ED-DB-TAP::4:CTAG::TID=BUROMESONET,TAPID=STS1-1-1-1-1;
TID=BUROMESONET Test Identifier has to match with the TID set in the TAU table
for OME6500 DCS. TID used in this step are examples only.
TAPID=STS1-1-1-1-1 STS1-shelf#-slot#-port#-sts# shelf# = 1 to 36
slot# = 1 to 14 port# = 1 to 8, 101 to 164 sts# = 1 to 192
The TACCs use the same VT1/VT2/STS1 Facility AID to refer to the TACC. Two consecutive ports must be used where the lower one is used as <tap>.
2.2.4 Retrieve the TAP table: Enter Command: RTRV-DB-TAP::ALL:CTAG;
ALCATEL-LAB-BRTU 06-05-26 15:12:18 M D COMPLD /* TPID TID STATUS TAPID TAPID2 */ /* TYPE FR LC EQ TPA TCA */ /* CONCAID ACCESSRATE TAPTYPE TIMING S-TRACE */ /* OPTIONS */ " 4 BUROMESONET F STS1-1-1-1-1 OME6500 0 0 1 0 0 1 0 0 0 01
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 13
BRTU-95 TPID Assignment:
BRTU-93 TPID Assignment:
BRTU-93 TPID Assignment:
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
HS
HS
HS
HS
HS
HS
CO
M
eSC
U
PS
U
BRTU-95 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=95;)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
(8) Test Bus Max. per side (8) Test Bus Max. per side
1
2
3
4
5
6
7
8
9
10
11
12
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
LS
Tes
tL
S T
est
HS
HS
HS
HS
HS
HS
CO
M
eSC
U
PS
U
CO
M
eSC
U
PS
U
BRTU-95 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=95;)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
(8) Test Bus Max. per side (8) Test Bus Max. per side(8) Test Bus Max. per side (8) Test Bus Max. per side
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
BRTU-93 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=93;)
1 2 3 4 5 6
HS
HS
HS
HS
7 8 9 10
CO
M
eSC
U
PS
U
11 12 13 14 15 16 17 18 19
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Intf
c
LS
Intf
c
20 21
(8) Test Bus Max. per side (8) Test Bus Max. per side
1
2
3
4
5
6
7
8
9
10
11
12
13
14
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
BRTU-93 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=93;)
1 2 3 4 5 6
HS
HS
HS
HS
7 8 9 10
CO
M
eSC
U
PS
U
CO
M
eSC
U
PS
U
11 12 13 14 15 16 17 18 1911 12 13 14 15 16 17 18 19
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Intf
c
LS
Intf
c
20 21
(8) Test Bus Max. per side (8) Test Bus Max. per side(8) Test Bus Max. per side (8) Test Bus Max. per side
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
HS
HS
HS
HS
HS
HS
CO
M
eSC
U
PS
U
BRTU-99 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=99;)
HS
HS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
LS
Intf
c
LS
Intf
c
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
(8) Test Bus Max.
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
HS
HS
HS
HS
HS
HS
CO
M
eSC
U
PS
U
CO
M
eSC
U
PS
U
BRTU-99 Main Shelf (ED-ATTR-EQPT:::CTAG::SHELF=99;)
HS
HS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
LS
Intf
c
LS
Intf
c
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
LS
Tes
t
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
(8) Test Bus Max.
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 14
3.00 DS3 Circuit Access Test DS3 Circuit Access Test
Figure 3-1 Example of Test Circuit Layout with Hardwire Loop in Both Directions
Establish the access to the DCS to verify the configuration of the DCS and the BRTU. 3.0.1.1 Enter the following command to access DS3 circuit OME6500 DCS
Enter command: CONN-TACC-T3:BUROMESONET:STS1-2-1-1-1:SPLTE; Response:
BUROMESONET 07-06-29 08:12:48
M 0 COMPLD
A
AID=STS1-1-4-5-2
NTD=A
Note: The command sent in this step is to access circuit in the OME6500 and Split the circuit to check
towards the Equipment direction. Verify the response from the access command is similar to the response as shown above. This is an indication of a successful access.
BRTU
6750-99
NORTEL
OME6500
F E
A Z
FAD
FAD
BRTU
6750-99
NORTEL
OME6500
F E
A Z
FAD
FAD
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 15
VT1 Payload Facility AID
VT1 payload on OCn VT1-shelf#-slot#-port#-sts#-vtg#-vt# VT1-shelf#-slot#-port#-sts#-ALL shelf# = 1 to 36 slot# = 1 to 14 port# = 1 to 8 sts# = 1 to 192 vtg# = 1 to 7 vt# = 1 to 4
VT1 payload On EC1 VT1-shelf#-slot#-port#-1-vtg#-vt# VT1-shelf#-slot#-port#-1-ALL shelf# = 1 to 36 slot# = 1 to 4, 9 to 12 port# = 1 to 24 vtg# = 1 to 7 vt# = 1 to 4
AU4 mapped VT1 payload VT1AU4-shelf#-slot#-port#-sts3c#-sts#-vtg#-vt# VT1AU4-shelf#-slot#-port#-sts3c#-sts#-ALL shelf# = 1 to 36 slot# = 1 to 14 port# = 1 to 8 sts3c# = 1, 4, 7, … 190 sts# = 1 to 3 vtg# = 1 to 7 vt# = 1 to 4
VT1 payload on DSM VT1-1-port#-%HLINK-OC3-hshelf#-hslot#-hport# port# = 1 to 84 hshelf# = 1 to 36 hslot# = 1 to 14 hport# = 1 to 8
VT1 payload on TMUX card VT1DS3-shelf#-slot#-port#-t2channel#-t1channel# VT1DS3-shelf#-slot#-port#-ALL VT1DS3-shelf#-slot#-ALL shelf# = 1 to 36 slot# = 1 to 14 port# = 1 to 8 t2channel# = 1 to 7 t1channel# = 1 to 4
DS3 facility AID
DS3 on DSM DS3-1-port#-%HLINK-OC3-hshelf#-hslot#-hport# port# = 1 to 84
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 16
hshelf# = 1 to 36 hslot# = 1 to 14 hport# = 1 to 8
DS3 on TMUX card DS3DS3-shelf#-slot#-port#-t2channel#-t1channel# DS3DS3-shelf#-slot#-port#-ALL DS3DS3-shelf#-slot#-ALL shelf# = 1 to 36 slot# = 1 to 14 port# = 1 to 8 t2channel# = 1 to 7 t1channel# = 1 to 4
3.0.1.2 Retrieve the access information and verify the test access by entering the following command
Enter Command: RTRV-COND-TST:::CTAG; ILABBRTU 07-06-29 08:12:57
M 0 COMPLD
/*SPIRENT COMMUNICATIONS OF ROCKVILLE - COPYRIGHT (C) 1997-2007 */
/*MODEL 6750 BRTU */
/*TSN JID TID AID MODE INTF TST */
" 999 J33 BUROMESONET STS1-2-1-1-1
SPLTE DS3 1-11-1-8 " 3.0.1.3 Insert test signal Enter Command: CHG-TSTSIG-T3::999:ATP:QRS:M,B;
BUROMESONET 06-08-25 14:59:09 M D COMPLD
3.0.1.4 Start the test by entering the following command: Enter Command: MEAS-SIG-T3::999:ATP:1,15,QRS,M,B,CBP;
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 17
3.0.1.5 Display the test results by entering the following command: Enter Command: REPT-RSLT::999:CTAG;
BUROMESONET 06-08-25 14:59:34 M CTAG COMPLD 0-06, 0 01-00, 0 PAT ES = 0 PAT TE = 0 PAT SES = 0 BPV ES = 0 BPV TE = 0 PARITY = 0 FRBERR =0
Verify the test results returns with no error 3.0.1.6 Insert Bit error by entering the following command: Enter Command: TST-INSERRBITS::999:D:45,,BIT; Note – This command injects 45 bit error in the test. Verify the error by displaying the results by entering the command in the next step. 3.0.1.7 Display the test results by entering the following command: Enter Command: REPT-RSLT::999:CTAG;
BUROMESONET 06-08-25 14:59:34 M CTAG COMPLD 0-06, 0 01-00, 0 PAT ES = 0 PAT TE = 0 PAT SES = 0 BPV ES = 0 BPV TE = 45 PARITY = 0 FRBERR =0
Verify results return with 45 Bit Error 3.0.1.8 Stop the test by entering the following command: Enter Command: DISC-TACC::999:CTAG;
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 18
3.0.1.9 Establish the access to FACILITY direction by entering the following command:
Enter Command: CONN-TACC-T3:BUROMESONET:STS1-2-1-1-1:SPLTF;
BUROMESONET 06-08-25 15:13:09 M D COMPLD
3.0.1.10 Insert test signal Enter Command: CHG-TSTSIG-T3::999:ATP:QRS:M,B;
BUROMESONET 06-08-25 14:59:09 M D COMPLD
3.0.1.11 Initiate the measurement by entering the following command: Enter Command: MEAS-SIG-T3::999:ATP:1,15,QRS,M,B,CBP;
3.0.1.12 Display the test results by entering the following command: Enter Command: REPT-RSLT::999:CTAG;
BUROMESONET 06-08-25 14:59:34 M CTAG COMPLD 0-06, 0 01-00, 0 PAT ES = 0 PAT TE = 0 PAT SES = 0 BPV ES = 0 BPV TE = 0 PARITY = 0 FRBERR =0
Verify the test results returns with no error
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 19
3.0.1.13 Insert Bit error by entering the following command: Enter Command: TST-INSERRBITS::999:D:45,,BIT; Note – This command injects 70 bit error in the test. Verify the error by displaying the results by entering the command in the next step. 3.0.1.14 Display the test results by entering the following command: Enter Command: REPT-RSLT::999:CTAG;
BUROMESONET 06-08-25 14:59:34 M CTAG COMPLD 0-06, 0 01-00, 0 PAT ES = 0 PAT TE = 0 PAT SES = 0 BPV ES = 0 BPV TE = 45 PARITY = 0 FRBERR =0 Verify the test results returns with no error Verify the error injected of 45 bit error appears in the test result
3.0.1.15 Release the access by entering the following command: Enter Command: DISC-TACC::999:CTAG;
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 20
4.0 REACT TEST RESOURCE CONFIGURATION FOR BRTU DS3 ACCESS WITH DS3 FAD INTERFACE. 4.1 Set the Telnet Database to include the address of the BRTU
%*BRTU 878 TCPIP_192.168.1.11_7010 IP address for BRTU
Note: Address and ports used are examples only; refer to REACT Admin for the
REACT Test resource for DS3 Test: 4.2 From REACT Administration click on EDIT then click on Test Resources (Old) and Edit Resources as shown in the example below. 4.3 Edit Resources should appear as shown below. Enter “2” to insert new test resource.
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 21
Enter the following information to create one DS3 Test Resource
Enter COM-LINK Direct/Modem/Remote/PAD X28 (D/M/R/P): R
6439 module, DATS, DC/B, ADM, none (6439/DATS/D/A/N): N
Enter ABILITY: ANALOG,CHANNELIZE,PERFORMANCE,ANALOG/CHANNELIZE,DDS, DS3/E3,CELLSITE,ISDN,ADM LOOP,DSLAM,ICON,ATM SW,ADSL RTR,IP TPUT,FR SW,STM,PON,STS1,STS3C,STS12C,VC3,STM1,STM4,IP_NA/C/P/(A/C)/DDS/3/S/I/ADML/D/ICON/SW/R/IP/F/M/PON/S1/S3/S12/VC3/STM1/STM4/IP_TLS/IP_VPN): 3
Is this a TR834 , natively supported , or foreign site (T/N/F): T
Enter Modem number: %*BRTU
Enter name (15 chars. max): BUROMESONET
Is this a CEPT device(Y/N)?: N
Is this a Hekimian BRTU (Y/N)?: Y
Is this resource a 6750 RTU or 6750 TSC? (R/T): T
Enter FAD/TAD hardware number, 0 disables FAD locking (00-99)?: 0
Is this a STSx TAD or other access(T/O)?: O
Is this a DS3 FAD, DS3 TAD, or other access(F/T/O)?: O
Individual DCS port, 6439 port (I/C): I Enter type of DCS/EDSX: WECO,WESCOM,DXCS,TELLABS,ATT3,TA203,D3-1,RDX,
TAIU,TITAN-S,TITAN-D,NTEL,DCSF,RTU,TDAX,NORTEL,DSXpert,TDAX NB,OTHER
(W,S,D,T,A,2,3,R,+,I,5,N,F,U,X,E,P,B,O): N
Enter DCS port:
Enter DCS link number, 0 to ignore: 0
Enter digroup/fad for test set: 1
Do you have a Remote controlled Reset Box for this resource (Y/N): N
Enter REACT 2001 primary test server host: HOST
Enter REACT 2001 secondary test server host: HOST
Enter REACT 2001 RTU Label: RTU
Display only this position? (y/n): Y
Application Guide for Model 6750 BRTU-93 DS3 FAD with OME6500
Spirent Communication Rev. A Page 22
4.4 Example of REACT Test Resource
TEST RESOURCE STATUS TYPE LONG TERM POS. TP/SIDE ABILITY LINK DEV. 3965 3705 MODEM/PORT1 PORT2 PASSWORD DCS/LNK D-PORT STATUS TEST NAME
----------------------------------------------------------------------------------------------------------------------------- ---- 192 001/- DS3 REMOTE ---- TSC %*BRTU TA/DPU NTEL/00 FREE FREE BUROMESONET
4.5 Establish the access using the REACT and verify a successful access from the REACT.
END