appendix b data definition schedule 2b_bim appendixb_mps… · appendix b data definition schedule...
TRANSCRIPT
Appendix B Data Definition Schedule
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD
Revisions VERSION DATE SECTIONS AUTHOR CHANGE DETAILS
A 3/11/2016 All CH2M Hill Initial Draft for Review
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 1
Contents Section Page
Overview ............................................................................................................................................ 3
General ............................................................................................................................................ 1-1 1.1 Equipment ........................................................................................................................ 1-1 1.2 Valves ............................................................................................................................... 1-2
Architectural .................................................................................................................................... 2-1 2.1 General ............................................................................................................................. 2-1 2.2 Walls ................................................................................................................................ 2-1 2.3 Doors ................................................................................................................................ 2-1 2.4 Casework .......................................................................................................................... 2-1 2.5 Plumbing Fixtures ............................................................................................................ 2-1
Structural ......................................................................................................................................... 3-1 3.1 General ............................................................................................................................. 3-1 3.2 Concrete Members .......................................................................................................... 3-1 3.3 Steel Members ................................................................................................................. 3-1 3.4 Penetrations ..................................................................................................................... 3-1
Electrical .......................................................................................................................................... 4-1 4.1 General ............................................................................................................................. 4-1 4.2 Light Fixtures .................................................................................................................... 4-1
Fire Protection ................................................................................................................................. 5-1 5.1 General ............................................................................................................................. 5-1 5.2 Sprinkler Heads ................................................................................................................ 5-1
Mechanical HVAC ............................................................................................................................. 6-1 6.1 General ............................................................................................................................. 6-1 6.2 Fans .................................................................................................................................. 6-1 6.3 Air Handling Units (AHU) ................................................................................................. 6-2 6.4 Dehumidification Units (DHU) ......................................................................................... 6-3
Plumbing, Piping and Equipment...................................................................................................... 7-1 7.1 General ............................................................................................................................. 7-1
Special Electrical .............................................................................................................................. 8-1 8.1 General ............................................................................................................................. 8-1
2 USAP BIM STANDARD – APPENDIX B REV A (DRAFT 11 MARCH 2016)
Overview This appendix documents required data definitions for objects in the BIM. These properties must be attached to the various types of objects, and their values filled in accurately.
The list of properties in each data definition was developed from two Operations drivers or use cases:
1. Operations users need to see these properties when navigating the model in 3D.
2. These properties will transfer to Maximo (this is a subset of the overall required properties).
The data definitions specify exact names that must be used; these standards must be followed for proper for consistency across the program and for successful integration with any other systems (e.g. Maximo).
Not sure if we want to additionally make this requirement:
In some cases the list of allowable values and/or data type (i.e. Integer, String) is also specified. Where this occurs, only those values and types are allowed.
Every data definition contains the following columns:
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
PROPERTY NAME The exact property name as it should appear in the BIM.
DESCRIPTION A brief description for user understanding only within this document; this is not intended to be implemented in the BIM.
OP-S Will this property transfer to the Operations System (e.g. Maximo)? This is yes/no (Y/N) designator.
EXAMPLES Real examples of values.
It is understood that the native BIM production software provides far more properties than these data definitions; these definitions only capture the properties necessary for integration with Operations activities and therefore required to be input accurately by BIM Owners. These properties are either considered “above and beyond” the native software properties, or they apply restrictions (such as naming standards) on native software properties.
Where a change or deviation from this Standard is deemed necessary, such change and the driving reason for it, must be communicated to the BIM Program Manager through the process described in Section 3.4.9 of the Standard.
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 3
SECTION 1
General The data definitions in this section are general in nature and apply to many types of objects in various disciplines.
1.1 Equipment This data definition is used for many different types of equipment, from electrical power devices such as wall outlets to major pieces of process equipment. This data definition is referenced throughout the document from various design discipline sections.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Horn, Outlet, Pull Station
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y
Fac Eng Discipline Design Discipline Architecture, Structural
Fac Eng System Design system within the Discipline Chilled Water, Fire Alarm
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 215
Material Material the object is made of Wood, Steel
Material Finish Finish of the material Painted, Annodized
Mfr Manufacturer name Y McQuay
Mfr Model Manufacturer model or submittal number Y CAH008GDGC
Mounting Surface component is mounted to Floor, Wall, Ceiling
Power-Circuit Electrical circuit device is on 9
Power-Control Control room of panel/circuit shutoff 120
Power-Panel Electrical panel where circuit is located L1
Power-Phase Electrical phase 3
Power-Voltage Electrical voltage 480
Remarks Any special remarks or comments
Size-Capacity Capacity 40 gal
Size-Depth Overall dimensional depth of object 23”, 7’-9”
Size-Height Overall dimensional height of object 16”, 2’-4”
Size-Length Overall dimensional length of object 32”, 16’-8 1/2”, 2’-9.5”
Size-Weight Weight of object 250lb
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 1-1
SECTION 1 – GENERAL
1.2 Valves This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Gate Valve
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y VLV-02
Fac Eng Discipline Design Discipline Mech HVAC, Fire Protection
Fac Eng System Design system within the Discipline Chilled Water, Fire Suppression
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 115
Size Size of valve 2”
1-2 USAP BIM STANDARD – APPENDIX B REV A (DRAFT 11 MARCH 2016)
SECTION 2
Architectural 2.1 General Many miscellaneous Architectural objects such as ladders, toilet accessories, manual fire extinguisher cabinets and other equipment use the General/Equipment Information data definition in Section 1.1.
2.2 Walls This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Wall, Partition
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y A
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Size-Depth Overall thickness or width of wall 8-1/2", 8.5”
Size-Height Overall dimensional height of object 10’, 8’-4”
2.3 Doors This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
2.4 Casework This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
2.5 Plumbing Fixtures This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 2-1
SECTION 3
Structural 3.1 General Some special Structural objects such as pipe hanger assemblies and fabricated steel assemblies can use the General/Equipment Information data definition in Section 1.1.
3.2 Concrete Members PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Area 1 Concrete Slab
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y 15
Member Type Structural member type Wall, Slab, Roof
Rating-Fire Required fire rating 2 HR
Thickness Width of wall, depth of slab 12”, 6”
3.3 Steel Members PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Steel Column
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y 15
Member Length Overall dimensional length of member 12’-5”
Member Type Structural member type Column, Beam
Rating-Fire Required fire rating 2 HR
Section Name Industry standard steel section name W12x120
3.4 Penetrations PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Penetration, Steel Tube Penetration
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y 15
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room 1 Room on one side of wall/floor Y 215
Fac Loc-Room 2 Room on other side of wall/floor Y 217
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 3-1
SECTION 3 – STRUCTURAL
Pen Depth Depth of wall or penetration 8”
Penetrant System penetrating the wall/floor Chilled Water, Elec Power
Rating-Fire Required fire rating 2 HR
Security Are there security concerns/devices? Y, N
Shape Shape of penetration Rectangular, Round
Sleeve Is the penetration sleeved, e.g. steel? Y, N
Structure Type of object housing penetration Wall, Floor, Roof
UL UL rated assembly number U
3-2 USAP BIM STANDARD – APPENDIX B REV A (DRAFT 11 MARCH 2016)
SECTION 4
Electrical 4.1 General All electrical devices such as power outlets, switches, transformers, UPS systems, use the General/Equipment Information data definition in Section 1.1.
4.2 Light Fixtures PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Light Fixture, 2x8 Industrial Light Fixture
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator from drawing or schedule Y F3
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 315
Material Material the object is made of Steel
Material Finish Finish of the material White Enamel
Lamp Quantity Number of lamps (i.e. bulbs) in the fixture 2
Lamp Type Type of lamps 4’ T8 Fluorescent
Mfr Manufacturer name Y Columbia
Mfr Model Manufacturer model or catalog number Y KL8-232-4EU-F0735
Mfr Type Type of fixture Heavy-Duty Industrial, Explosion-Proof
Mounting Surface component is mounted to Pendant, Wall, Ceiling, Roof
Power-Circuit Electrical circuit device is on 9
Power-Control Control room of panel/circuit shutoff 120
Power-Panel Electrical panel where circuit is located L1
Power-Phase Electrical phase 1
Power-Voltage Electrical voltage 277
Remarks Any special remarks or comments
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 4-1
SECTION 5
Fire Protection 5.1 General All electrical fire detection and alarm devices use the General/Equipment data definition in Section 1.1.
All fire suppression valves use the General/Valves data definition in Section 1.2.
5.2 Sprinkler Heads PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Sprinkler Head
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Sprinkler configuration/type Y Upright, Pendant, Ceiling, Recessed
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 105
Coverage (SF) Coverage of head 100
Hazard Rating The hazard rating of the head Ordinary Hazard, Extra Hazard
Material Material Brass
Mfr Manufacturer name Y Tyco
Mfr Model Manufacturer model or catalog number Y TY-FRL
Size Size of orifice 1/2"
Temp Rating Temperature rating of head 165 deg F
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 5-1
SECTION 6
Mechanical HVAC 6.1 General All electrical HVAC control devices use the General/Equipment data definition in Section 1.1.
All mechanical piping valves use the General/Valves data definition in Section 1.2.
6.2 Fans This data definition is under development.
PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y Fan
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y EF-02
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 115
Size-Depth Overall dimensional depth of object
Size-Height Overall dimensional height of object
Size-Length Overall dimensional length of object 8”
Size-Weight Weight of object 112 lb
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 6-1
SECTION 6 – MECHANICAL HVAC
6.3 Air Handling Units (AHU) PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y AHU, Air Handler, Inline Horiz AHU
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y AHU-02
Cool Capacity Cooling capacity 183071 Btu/h
Cool LAT 49.7/42.7 F
Cool Type Chilled Water
Design Altitude Design basis altitude, feet above sea level 2566
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 115
Fan Power 10.0 HP
Fan Static 3.53
Fan Type Centrifugal Direct-Drive Plenum
Filter Type-Final MERV 15
Filter Type-Pre MERV 8
Heat Capacity 260800 Btu/h
Heat LAT 81.9 F
Heat Type Steam
Mfr Manufacturer name Y McQuay
Mfr Model Manufacturer model or submittal number Y CAH008GDGC
Mounting Surface component is mounted to Floor, Housekeeping Pad
Power-Circuit Electrical circuit device is on 15
Power-Control Control room of panel/circuit shutoff 120
Power-Panel Electrical panel where circuit is located H1
Power-Phase Electrical phase 3
Power-Voltage Electrical voltage 460
Remarks Any special remarks or comments
Service Area serviced by unit Zone 1, Bay 2, Bldg 6043
Size-Depth Overall dimensional depth of object 74" (6'-2")
Size-Height Overall dimensional height of object 42" (3'-6")
Size-Length Overall dimensional length of object 204" (17'-0")
Size-Weight Weight of object 3262 lb
Volume-Return 4300 cfm
Volume-Supply 6500 cfm
6-2 USAP BIM STANDARD – APPENDIX B REV A (DRAFT 11 MARCH 2016)
SECTION 6 – MECHANICAL HVAC
6.4 Dehumidification Units (DHU) PROPERTY NAME DESCRIPTION OP-S EXAMPLES
Comp Description Short description of object. Y DHU, Desiccant Dehumidifying Unit
Comp ID Asset Facility Operations/Maintenance asset ID Y 889-56-452467
Comp ID Type Type designator, typ from design drawings Y DHU-04
Dehumidifier Capacity Cooling capacity 24 lb/hr
Dehumidifier Type Silica Gel Desiccant Wheel
Design Altitude Design basis altitude, feet above sea level 2566
Fac Loc-Bldg Facility building number or designator Y 889-56
Fac Loc-Floor Facility floor Y 1st, 2nd
Fac Loc-Room Room number Y 115
Mfr Manufacturer name Y Munters
Mfr Model Manufacturer model or submittal number Y HCD-1125-SA-SBCFS
Mounting Surface component is mounted to Floor, Housekeeping Pad
Power-Circuit Electrical circuit device is on 17
Power-Control Control room of panel/circuit shutoff 120
Power-Panel Electrical panel where circuit is located H1
Power-Phase Electrical phase 3
Power-Voltage Electrical voltage 460
Proc Air Cool Cap 57,300 Btu/hr
Proc Air Cool Type Chilled Water
Proc Air Fan Power 2 HP
Proc Air Fan Static 5.8
Proc Air Filter Type 30%
Proc Air LA Moisture 8.3 gr/lb
Proc Air LAT 67 F
Proc Air Vol 1125 cfm
React Air Fan Power 1.5 HP
React Air Fan Static 6.6
React Air Filter Type 30%
React Air Heat Cap 68,904 Btu/hr
React Air Heat Type Steam
React Air LAT 295 F
React Air PreHeat Cap 21,883 Bth/hr
React Air PreHeat Type Plate Air-to-Air
React Air Vol 275 cfm
Remarks Any special remarks or comments
Service Area serviced by unit Zone 1, Bay 2, Bldg 6043
USAP BIM STANDARD – 95% DRAFT (26 FEB 2016) CH2M HILL, INC. 6-3
SECTION 6 – MECHANICAL HVAC
Size-Depth Overall dimensional depth of object 70" (5'-10")
Size-Height Overall dimensional height of object 72" (6'-0")
Size-Length Overall dimensional length of object 143" (11'-11")
Size-Weight Weight of object 1925 lb
6-4 USAP BIM STANDARD – APPENDIX B REV A (DRAFT 11 MARCH 2016)
SECTION 7
Plumbing, Piping and Equipment 7.1 General All process equipment, including major pieces (a press or a tank), minor pieces (pumps), and electrical devices (controls) use the General/Equipment data definition in Section 1.1.
All piping valves use the General/Valves data definition in Section 1.2.
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 7-1
SECTION 8
Special Electrical 8.1 General This section covers all electrical systems that are not power and lighting; this includes systems such as Telecommunications, Video, Network/Data, Telephone, Intercom, Security, etc.
All special electrical devices use the General/Equipment data definition in Section 1.1.
REV A (DRAFT 11 MARCH 2016) USAP BIM STANDARD – APPENDIX B 8-1