api well no: 43047511750000 received: 7/21/2010fwellw ... · api number assigned 43047511750000...

64
STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NUMBER CWU 1538-25D 2. TYPE OF WORK DRILL NEW WELL REENTER P&A WELL DEEPEN WELL 3. FIELD OR WILDCAT NATURAL BUTTES 4. TYPE OF WELL Gas Well Coalbed Methane Well: NO 5. UNIT or COMMUNITIZATION AGREEMENT NAME CHAPITA WELLS 6. NAME OF OPERATOR EOG Resources, Inc. 7. OPERATOR PHONE 435 781-9111 8. ADDRESS OF OPERATOR 1060 East Highway 40, Vernal, UT, 84078 9. OPERATOR E-MAIL [email protected] 10. MINERAL LEASE NUMBER (FEDERAL, INDIAN, OR STATE) UTU0285A 11. MINERAL OWNERSHIP FEDERAL INDIAN STATE FEE 12. SURFACE OWNERSHIP FEDERAL INDIAN STATE FEE 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME (if box 12 = 'INDIAN') 18. INTEND TO COMMINGLE PRODUCTION FROM MULTIPLE FORMATIONS YES (Submit Commingling Application) NO 19. SLANT VERTICAL DIRECTIONAL HORIZONTAL 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY UINTAH 22. DISTANCE TO NEAREST LEASE LINE (Feet) 659 23. NUMBER OF ACRES IN DRILLING UNIT 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL (Applied For Drilling or Completed) 430 26. PROPOSED DEPTH MD: 9341 TVD: 9280 27. ELEVATION - GROUND LEVEL 5022 28. BOND NUMBER NM2308 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 49-225 ATTACHMENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED 43047511750000 Permit Manager APPROVAL FORM 3 AMENDED REPORT API Well No: 43047511750000 Received: 7/21/2010 API Well No: 43047511750000 Received: 7/21/2010 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMB1E5R38-25D 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELLI REENTER P&A WELL DEEPEN WELL I NATURAL BUTTES 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Gas Well Coalbed Methane Well: NO CHAPITA WELLS 6. NAME OF OPERATOR 7. OPERATOR PHONE EOG Resources, Inc. 435 781-9111 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL 1060 East Highway 40, Vernal, UT, 84078 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL,INDIAN,ORUSTU8A FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT UINTAH 659 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 9341 TVD: 9280 430 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5022 NM2308 49-225 ATTACHMENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43047511750000 I Permit API Well No: 43047511750000 Received: 7/21/2010 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU 1E5R38-25D 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Gas Well Coalbed Methane Well: NO CHAPITA WELLS 6. NAME OF OPERATOR 7. OPERATOR PHONE EOG Resources, Inc. 435 781-9111 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL 1060 East Highway 40, Vernal, UT, 84078 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL,INDIAN,ORUSTUA)A FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT UINTAH 659 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 9341 TVD: 9280 430 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5022 NM2308 49-225 ATTACH MENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43047511750000 I Permit API Well No: 43047511750000 Received: 7/21/2010 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU 1E5R38-25D 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Gas Well Coalbed Methane Well: NO CHAPITA WELLS 6. NAME OF OPERATOR 7. OPERATOR PHONE EOG Resources, Inc. 435 781-9111 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL 1060 East Highway 40, Vernal, UT, 84078 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL,INDIAN,ORUSTUA)A FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT UINTAH 659 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 9341 TVD: 9280 430 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5022 NM2308 49-225 ATTACH MENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43047511750000 I Permit API Well No: 43047511750000 Received: 7/21/2010 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU 1E5R38-25D 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Gas Well Coalbed Methane Well: NO CHAPITA WELLS 6. NAME OF OPERATOR 7. OPERATOR PHONE EOG Resources, Inc. 435 781-9111 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL 1060 East Highway 40, Vernal, UT, 84078 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL,INDIAN,ORUSTUA)A FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT UINTAH 659 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 9341 TVD: 9280 430 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5022 NM2308 49-225 ATTACH MENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43047511750000 I Permit API Well No: 43047511750000 Received: 7/21/2010 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU 1E5R38-25D 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Gas Well Coalbed Methane Well: NO CHAPITA WELLS 6. NAME OF OPERATOR 7. OPERATOR PHONE EOG Resources, Inc. 435 781-9111 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL 1060 East Highway 40, Vernal, UT, 84078 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL,INDIAN,ORUSTUA)A FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT UINTAH 659 1800 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 9341 TVD: 9280 430 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5022 NM2308 49-225 ATTACH MENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157 SIGNATURE DATE 07/21/2010 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43047511750000 I Permit

Upload: others

Post on 14-Mar-2021

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NUMBER

CWU 1538-25D

2. TYPE OF WORK

DRILL NEW WELL REENTER P&A WELL DEEPEN WELL 3. FIELD OR WILDCAT

NATURAL BUTTES

4. TYPE OF WELLGas Well Coalbed Methane Well: NO

5. UNIT or COMMUNITIZATION AGREEMENT NAMECHAPITA WELLS

6. NAME OF OPERATOREOG Resources, Inc.

7. OPERATOR PHONE435 781-9111

8. ADDRESS OF OPERATOR1060 East Highway 40, Vernal, UT, 84078

9. OPERATOR [email protected]

10. MINERAL LEASE NUMBER(FEDERAL, INDIAN, OR STATE)

UTU0285A

11. MINERAL OWNERSHIP

FEDERAL INDIAN STATE FEE 12. SURFACE OWNERSHIP

FEDERAL INDIAN STATE FEE

13. NAME OF SURFACE OWNER (if box 12 = 'fee')

14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee')

16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME(if box 12 = 'INDIAN')

18. INTEND TO COMMINGLE PRODUCTION FROMMULTIPLE FORMATIONS

YES (Submit Commingling Application) NO

19. SLANT

VERTICAL DIRECTIONAL HORIZONTAL

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTYUINTAH

22. DISTANCE TO NEAREST LEASE LINE (Feet)659

23. NUMBER OF ACRES IN DRILLING UNIT1800

25. DISTANCE TO NEAREST WELL IN SAME POOL(Applied For Drilling or Completed)

430

26. PROPOSED DEPTHMD: 9341 TVD: 9280

27. ELEVATION - GROUND LEVEL

5022

28. BOND NUMBER

NM2308

29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

49-225

ATTACHMENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY

DRILLED)

TOPOGRAPHICAL MAP

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED

43047511750000

Permit Manager

APPROVAL

FORM 3

AMENDED REPORT

API Well No: 43047511750000 Received: 7/21/2010API Well No: 43047511750000 Received: 7/21/2010

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMB1E5R38-25D

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELLI REENTER P&A WELL DEEPEN WELL I NATURAL BUTTES

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO CHAPITA WELLS

6. NAME OF OPERATOR 7. OPERATOR PHONEEOG Resources, Inc. 435 781-9111

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL1060 East Highway 40, Vernal, UT, 84078 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORUSTU8A

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN') MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITUINTAH 659 1800

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 9341 TVD: 9280

430

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5022 NM2308 49-225

ATTACHMENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43047511750000 I

Permit

API Well No: 43047511750000 Received: 7/21/2010

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU1E5R38-25D

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO CHAPITA WELLS

6. NAME OF OPERATOR 7. OPERATOR PHONEEOG Resources, Inc. 435 781-9111

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL1060 East Highway 40, Vernal, UT, 84078 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORUSTUA)A

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN')MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITUINTAH 659 1800

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 9341 TVD: 9280

430

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5022 NM2308 49-225

ATTACH MENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43047511750000 I

Permit

API Well No: 43047511750000 Received: 7/21/2010

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU1E5R38-25D

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO CHAPITA WELLS

6. NAME OF OPERATOR 7. OPERATOR PHONEEOG Resources, Inc. 435 781-9111

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL1060 East Highway 40, Vernal, UT, 84078 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORUSTUA)A

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN')MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITUINTAH 659 1800

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 9341 TVD: 9280

430

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5022 NM2308 49-225

ATTACH MENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43047511750000 I

Permit

API Well No: 43047511750000 Received: 7/21/2010

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU1E5R38-25D

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO CHAPITA WELLS

6. NAME OF OPERATOR 7. OPERATOR PHONEEOG Resources, Inc. 435 781-9111

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL1060 East Highway 40, Vernal, UT, 84078 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORUSTUA)A

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN')MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITUINTAH 659 1800

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 9341 TVD: 9280

430

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5022 NM2308 49-225

ATTACH MENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43047511750000 I

Permit

API Well No: 43047511750000 Received: 7/21/2010

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NCUWMU1E5R38-25D

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELL I REENTER P&A WELL DEEPEN WELL i NATURAL BUTTES

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEGas Well Coalbed Methane Well: NO CHAPITA WELLS

6. NAME OF OPERATOR 7. OPERATOR PHONEEOG Resources, Inc. 435 781-9111

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL1060 East Highway 40, Vernal, UT, 84078 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL,INDIAN,ORUSTUA)A

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATEI FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN')MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 673 FNL 746 FWL NWNW 25 9.0 S 22.0 E S

Top of Uppermost Producing Zone 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

At Total Depth 1265 FNL 659 FWL NWNW 25 9.0 S 22.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITUINTAH 659 1800

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 9341 TVD: 9280

430

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5022 NM2308 49-225

ATTACH MENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORDANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Nanette Lupcho TITLE Regulatory Assistant PHONE 435 781-9157

SIGNATURE DATE 07/21/2010 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43047511750000 I

Permit

Page 2: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341 11.6

API Well No: 43047511750000 Received: 7/21/2010API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 4.5 0 9339

Pipe Grade Length Weight

Grade N-80 LT&C 9341

Page 3: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300 36.0

API Well No: 43047511750000 Received: 7/21/2010API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300

API Well No: 43047511750000 Received: 7/21/2010

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 9.625 0 2300

Pipe Grade Length Weight

Grade J-55 ST&C 2300

Page 4: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000'

EOG

RESO

UR

CES,

INC

.

T9S,R

22E,S.L.B

.&M

.gg

"heInocation,

CW

WU

53N8

D,

locSaeces25,

EETes,

R22E,

S.L.B.&

M.,

Uintah

County,

Utah.

Brass

Cap

SB978'46"W

-

2641.71'(M

eas.)SB

9°52'17"W-

2640.40'(M

eas.)BA

SISOF

ELEVATIO

NB

rasscap

Brass

capB

ENC

HM

AR

K20EA

MLO

CA

TEDIN

THE

SE1/4

OF

SECTIO

N-

½35,

T8S,R

21E,S.L.B

.&M

.TA

KEN

FRO

MTH

EO

UR

AY

SE,Q

UA

DR

AN

GLE, U

TAH

,U

INTA

HC

OU

NTY

,7.5M

INU

TEQ

UA

D.

(TOPO

GR

APH

ICM

AP)

PUB

LISHED

BY

THE

UN

ITEDSTA

TESD

EPAR

TMEN

TO

FTH

EIN

TERIO

R,G

EOLO

GIC

ALSU

RV

EY.SA

IDC

WU

F538-25DELEV

ATIO

NIS

MA

RK

EDA

SB

EING

4697FEET.

E/ev.U

ngradedG

round=

5022'B

ASIS

OF

BEA

RIN

GS

659'B

ASIS

OF

BEA

RIN

GS

ISA

G.P.S.

OB

SERV

ATIO

N.

BO

TTOM

HO

LE

LINE

TAB

LELIN

EB

EAR

ING

LENG

THL1

SO8°06'06"W

598.44'N

1977B

rassC

ap0.8'

High,

Pileof

Stones

25B

rassC

ap

SCA

LE

CER

TIFICA

TEL

AN

DTH

ISIS

TOC

ERTIFY

THA

TTH

EA

BO

VE

PL-

FIELDN

OTES

OF

AC

TUA

LSU

RV

EYS

MA

DE

RU

ND

ESU

PERV

ISION

AN

DTH

AT

THE

SAM

EA

RI

CFT

BEST

OF

MY

KN

OW

LEDG

EAN

DB

ELIEF.

RE

ISTELA

SUR

REG

ISTRA

1977B

rassC

ap1977

Brass

Cap

Revised:

11-16-09D

.R.B

.STA

TEO

F0.4'

High,

Steel1.0'

High,

SteelPost,

Pileof

Post,P//e

ofstones

stonesB

rasscap

UIN

TAH

ENG

INEER

ING

&LA

ND

SUR

VEY

ING

NB

9°55'47"W-

2616.98'(M

eas.)N

B9°46'55"W

-

265J.67'(M

eas.)85

SOU

TH200

EAST

-

VER

NA

L,U

TAH

840'78(435)

789-1017

LEGEN

D:

SCA

LED

ATE

SUR

VEY

ED:

DA

TED

RA

WN

:1"

=1000°

10-05-0910-20-09

=90°

SYM

BO

LN

AD

83(TA

RG

ETB

OTTO

MH

OLE)

NA

D83

(SUR

FAC

ELO

CA

TION

)PA

RTY

REFER

ENC

ESLA

TITUD

E=

4000'38.79"

(40.010775)LA

TITUD

E=

40°00'44.65"(40.012403)

=PR

OPO

SEDW

ELLH

EAD

.LO

NG

ITUD

E=

109°23'43.41"(109.395392)

LON

GITU

DE

=109°23'42.32"

(109.395089)G

.S.C

.R.

D.R

.B.

G.L.O

.PLA

TN

AD

27(TA

RG

ETB

OTTO

MH

OLE)

NA

D27

(SUR

FAC

ELO

CA

TION

)W

FATH

FRFILE

A=

SECTIO

NC

OR

NER

SLO

CA

TED.

LATITU

DE

=40°00'38.92"

(40.010811)LA

TITUD

E=

40°00'44.77"(40.012436)

LON

GITU

DE

=10923°40.96"

(109.394710)LO

NG

ITUD

E=

10923'39.87"(109.394408)

OO

LEO

GR

ESOU

RC

ES,

EOG

RESO

UR

CES,

INC

.

T9S,R

22E,S.L.B

.&M

.gg

"heInocation,

CW

WU

53N8

D,

locSaeces25,

EETes,

R22E,

S.L.B.&

M.,

Uintah

County,

Utah.

Brass

Cap

SB978'46"W

-

2641.71'(M

eas.)SB

9°52'17"W-

2640.40'(M

eas.)BA

SISOF

ELEVATIO

NB

rasscap

Brass

capB

ENC

HM

AR

K20EA

MLO

CA

TEDIN

THE

SE1/4

OF

SECTIO

N-

½35,

T8S,R

21E,S.L.B

.&M

.TA

KEN

FRO

MTH

EO

UR

AY

SE,Q

UA

DR

AN

GLE, U

TAH

,U

INTA

HC

OU

NTY

,7.5M

INU

TEQ

UA

D.

(TOPO

GR

APH

ICM

AP)

PUB

LISHED

BY

THE

UN

ITEDSTA

TESD

EPAR

TMEN

TO

FTH

EIN

TERIO

R,G

EOLO

GIC

ALSU

RV

EY.SA

IDC

WU

F538-25DELEV

ATIO

NIS

MA

RK

EDA

SB

EING

4697FEET.

E/ev.U

ngradedG

round=

5022'B

ASIS

OF

BEA

RIN

GS

659'B

ASIS

OF

BEA

RIN

GS

ISA

G.P.S.

OB

SERV

ATIO

N.

BO

TTOM

HO

LE

LINE

TAB

LELIN

EB

EAR

ING

LENG

THL1

SO8°06'06"W

598.44'N

1977B

rassC

ap0.8'

High,

Pileof

Stones

25B

rassC

ap

SCA

LE

CER

TIFICA

TEL

AN

DTH

ISIS

TOC

ERTIFY

THA

TTH

EA

BO

VE

PL-

FIELDN

OTES

OF

AC

TUA

LSU

RV

EYS

MA

DE

RU

ND

ESU

PERV

ISION

AN

DTH

AT

THE

SAM

EA

RI

CFT

BEST

OF

MY

KN

OW

LEDG

EAN

DB

ELIEF.

RE

ISTELA

SUR

REG

ISTRA

1977B

rassC

ap1977

Brass

Cap

Revised:

11-16-09D

.R.B

.STA

TEO

F0.4'

High,

Steel1.0'

High,

SteelPost,

Pileof

Post,P//e

ofstones

stonesB

rasscap

UIN

TAH

ENG

INEER

ING

&LA

ND

SUR

VEY

ING

NB

9°55'47"W-

2616.98'(M

eas.)N

B9°46'55"W

-

265J.67'(M

eas.)85

SOU

TH200

EAST

-

VER

NA

L,U

TAH

840'78(435)

789-1017

LEGEN

D:

SCA

LED

ATE

SUR

VEY

ED:

DA

TED

RA

WN

:1"

=1000°

10-05-0910-20-09

=90°

SYM

BO

LN

AD

83(TA

RG

ETB

OTTO

MH

OLE)

NA

D83

(SUR

FAC

ELO

CA

TION

)PA

RTY

REFER

ENC

ESLA

TITUD

E=

4000'38.79"

(40.010775)LA

TITUD

E=

40°00'44.65"(40.012403)

=PR

OPO

SEDW

ELLH

EAD

.LO

NG

ITUD

E=

109°23'43.41"(109.395392)

LON

GITU

DE

=109°23'42.32"

(109.395089)G

.S.C

.R.

D.R

.B.

G.L.O

.PLA

TN

AD

27(TA

RG

ETB

OTTO

MH

OLE)

NA

D27

(SUR

FAC

ELO

CA

TION

)W

FATH

FRFILE

A=

SECTIO

NC

OR

NER

SLO

CA

TED.

LATITU

DE

=40°00'38.92"

(40.010811)LA

TITUD

E=

40°00'44.77"(40.012436)

LON

GITU

DE

=10923°40.96"

(109.394710)LO

NG

ITUD

E=

10923'39.87"(109.394408)

OO

LEO

GR

ESOU

RC

ES,

EOG

RESO

UR

CES,

INC

.

T9S,R

22E,S.L.B

.&M

.gg

"heInocation,

CW

WU

53N8

D,

locSaeces25,

EETes,

R22E,

S.L.B.&

M.,

Uintah

County,

Utah.

Brass

Cap

SB978'46"W

-

2641.71'(M

eas.)SB

9°52'17"W-

2640.40'(M

eas.)BA

SISOF

ELEVATIO

NB

rasscap

Brass

capB

ENC

HM

AR

K20EA

MLO

CA

TEDIN

THE

SE1/4

OF

SECTIO

N-

½35,

T8S,R

21E,S.L.B

.&M

.TA

KEN

FRO

MTH

EO

UR

AY

SE,Q

UA

DR

AN

GLE, U

TAH

,U

INTA

HC

OU

NTY

,7.5M

INU

TEQ

UA

D.

(TOPO

GR

APH

ICM

AP)

PUB

LISHED

BY

THE

UN

ITEDSTA

TESD

EPAR

TMEN

TO

FTH

EIN

TERIO

R,G

EOLO

GIC

ALSU

RV

EY.SA

IDC

WU

F538-25DELEV

ATIO

NIS

MA

RK

EDA

SB

EING

4697FEET.

E/ev.U

ngradedG

round=

5022'B

ASIS

OF

BEA

RIN

GS

659'B

ASIS

OF

BEA

RIN

GS

ISA

G.P.S.

OB

SERV

ATIO

N.

BO

TTOM

HO

LE

LINE

TAB

LELIN

EB

EAR

ING

LENG

THL1

SO8°06'06"W

598.44'N

1977B

rassC

ap0.8'

High,

Pileof

Stones

25B

rassC

ap

SCA

LE

CER

TIFICA

TEL

AN

DTH

ISIS

TOC

ERTIFY

THA

TTH

EA

BO

VE

PL-

FIELDN

OTES

OF

AC

TUA

LSU

RV

EYS

MA

DE

RU

ND

ESU

PERV

ISION

AN

DTH

AT

THE

SAM

EA

RI

CFT

BEST

OF

MY

KN

OW

LEDG

EAN

DB

ELIEF.

RE

ISTELA

SUR

REG

ISTRA

1977B

rassC

ap1977

Brass

Cap

Revised:

11-16-09D

.R.B

.STA

TEO

F0.4'

High,

Steel1.0'

High,

SteelPost,

Pileof

Post,P//e

ofstones

stonesB

rasscap

UIN

TAH

ENG

INEER

ING

&LA

ND

SUR

VEY

ING

NB

9°55'47"W-

2616.98'(M

eas.)N

B9°46'55"W

-

265J.67'(M

eas.)85

SOU

TH200

EAST

-

VER

NA

L,U

TAH

840'78(435)

789-1017

LEGEN

D:

SCA

LED

ATE

SUR

VEY

ED:

DA

TED

RA

WN

:1"

=1000°

10-05-0910-20-09

=90°

SYM

BO

LN

AD

83(TA

RG

ETB

OTTO

MH

OLE)

NA

D83

(SUR

FAC

ELO

CA

TION

)PA

RTY

REFER

ENC

ESLA

TITUD

E=

4000'38.79"

(40.010775)LA

TITUD

E=

40°00'44.65"(40.012403)

=PR

OPO

SEDW

ELLH

EAD

.LO

NG

ITUD

E=

109°23'43.41"(109.395392)

LON

GITU

DE

=109°23'42.32"

(109.395089)G

.S.C

.R.

D.R

.B.

G.L.O

.PLA

TN

AD

27(TA

RG

ETB

OTTO

MH

OLE)

NA

D27

(SUR

FAC

ELO

CA

TION

)W

FATH

FRFILE

A=

SECTIO

NC

OR

NER

SLO

CA

TED.

LATITU

DE

=40°00'38.92"

(40.010811)LA

TITUD

E=

40°00'44.77"(40.012436)

LON

GITU

DE

=10923°40.96"

(109.394710)LO

NG

ITUD

E=

10923'39.87"(109.394408)

OO

LEO

GR

ESOU

RC

ES,

EOG

RESO

UR

CES,

INC

.

T9S,R

22E,S.L.B

.&M

.gg

"heInocation,

CW

WU

53N8

D,

locSaeces25,

EETes,

R22E,

S.L.B.&

M.,

Uintah

County,

Utah.

Brass

Cap

SB978'46"W

-

2641.71'(M

eas.)SB

9°52'17"W-

2640.40'(M

eas.)BA

SISOF

ELEVATIO

NB

rasscap

Brass

capB

ENC

HM

AR

K20EA

MLO

CA

TEDIN

THE

SE1/4

OF

SECTIO

N-

½35,

T8S,R

21E,S.L.B

.&M

.TA

KEN

FRO

MTH

EO

UR

AY

SE,Q

UA

DR

AN

GLE, U

TAH

,U

INTA

HC

OU

NTY

,7.5M

INU

TEQ

UA

D.

(TOPO

GR

APH

ICM

AP)

PUB

LISHED

BY

THE

UN

ITEDSTA

TESD

EPAR

TMEN

TO

FTH

EIN

TERIO

R,G

EOLO

GIC

ALSU

RV

EY.SA

IDC

WU

F538-25DELEV

ATIO

NIS

MA

RK

EDA

SB

EING

4697FEET.

E/ev.U

ngradedG

round=

5022'B

ASIS

OF

BEA

RIN

GS

659'B

ASIS

OF

BEA

RIN

GS

ISA

G.P.S.

OB

SERV

ATIO

N.

BO

TTOM

HO

LE

LINE

TAB

LELIN

EB

EAR

ING

LENG

THL1

SO8°06'06"W

598.44'N

1977B

rassC

ap0.8'

High,

Pileof

Stones

25B

rassC

ap

SCA

LE

CER

TIFICA

TEL

AN

DTH

ISIS

TOC

ERTIFY

THA

TTH

EA

BO

VE

PL-

FIELDN

OTES

OF

AC

TUA

LSU

RV

EYS

MA

DE

RU

ND

ESU

PERV

ISION

AN

DTH

AT

THE

SAM

EA

RI

CFT

BEST

OF

MY

KN

OW

LEDG

EAN

DB

ELIEF.

RE

ISTELA

SUR

REG

ISTRA

1977B

rassC

ap1977

Brass

Cap

Revised:

11-16-09D

.R.B

.STA

TEO

F0.4'

High,

Steel1.0'

High,

SteelPost,

Pileof

Post,P//e

ofstones

stonesB

rasscap

UIN

TAH

ENG

INEER

ING

&LA

ND

SUR

VEY

ING

NB

9°55'47"W-

2616.98'(M

eas.)N

B9°46'55"W

-

265J.67'(M

eas.)85

SOU

TH200

EAST

-

VER

NA

L,U

TAH

840'78(435)

789-1017

LEGEN

D:

SCA

LED

ATE

SUR

VEY

ED:

DA

TED

RA

WN

:1"

=1000°

10-05-0910-20-09

=90°

SYM

BO

LN

AD

83(TA

RG

ETB

OTTO

MH

OLE)

NA

D83

(SUR

FAC

ELO

CA

TION

)PA

RTY

REFER

ENC

ESLA

TITUD

E=

4000'38.79"

(40.010775)LA

TITUD

E=

40°00'44.65"(40.012403)

=PR

OPO

SEDW

ELLH

EAD

.LO

NG

ITUD

E=

109°23'43.41"(109.395392)

LON

GITU

DE

=109°23'42.32"

(109.395089)G

.S.C

.R.

D.R

.B.

G.L.O

.PLA

TN

AD

27(TA

RG

ETB

OTTO

MH

OLE)

NA

D27

(SUR

FAC

ELO

CA

TION

)W

FATH

FRFILE

A=

SECTIO

NC

OR

NER

SLO

CA

TED.

LATITU

DE

=40°00'38.92"

(40.010811)LA

TITUD

E=

40°00'44.77"(40.012436)

LON

GITU

DE

=10923°40.96"

(109.394710)LO

NG

ITUD

E=

10923'39.87"(109.394408)

OO

LEO

GR

ESOU

RC

ES,

EOG

RESO

UR

CES,

INC

.

T9S,R

22E,S.L.B

.&M

.gg

"heInocation,

CW

WU

53N8

D,

locSaeces25,

EETes,

R22E,

S.L.B.&

M.,

Uintah

County,

Utah.

Brass

Cap

SB978'46"W

-

2641.71'(M

eas.)SB

9°52'17"W-

2640.40'(M

eas.)BA

SISOF

ELEVATIO

NB

rasscap

Brass

capB

ENC

HM

AR

K20EA

MLO

CA

TEDIN

THE

SE1/4

OF

SECTIO

N-

½35,

T8S,R

21E,S.L.B

.&M

.TA

KEN

FRO

MTH

EO

UR

AY

SE,Q

UA

DR

AN

GLE, U

TAH

,U

INTA

HC

OU

NTY

,7.5M

INU

TEQ

UA

D.

(TOPO

GR

APH

ICM

AP)

PUB

LISHED

BY

THE

UN

ITEDSTA

TESD

EPAR

TMEN

TO

FTH

EIN

TERIO

R,G

EOLO

GIC

ALSU

RV

EY.SA

IDC

WU

F538-25DELEV

ATIO

NIS

MA

RK

EDA

SB

EING

4697FEET.

E/ev.U

ngradedG

round=

5022'B

ASIS

OF

BEA

RIN

GS

659'B

ASIS

OF

BEA

RIN

GS

ISA

G.P.S.

OB

SERV

ATIO

N.

BO

TTOM

HO

LE

LINE

TAB

LELIN

EB

EAR

ING

LENG

THL1

SO8°06'06"W

598.44'N

1977B

rassC

ap0.8'

High,

Pileof

Stones

25B

rassC

ap

SCA

LE

CER

TIFICA

TEL

AN

DTH

ISIS

TOC

ERTIFY

THA

TTH

EA

BO

VE

PL-

FIELDN

OTES

OF

AC

TUA

LSU

RV

EYS

MA

DE

RU

ND

ESU

PERV

ISION

AN

DTH

AT

THE

SAM

EA

RI

CFT

BEST

OF

MY

KN

OW

LEDG

EAN

DB

ELIEF.

RE

ISTELA

SUR

REG

ISTRA

1977B

rassC

ap1977

Brass

Cap

Revised:

11-16-09D

.R.B

.STA

TEO

F0.4'

High,

Steel1.0'

High,

SteelPost,

Pileof

Post,P//e

ofstones

stonesB

rasscap

UIN

TAH

ENG

INEER

ING

&LA

ND

SUR

VEY

ING

NB

9°55'47"W-

2616.98'(M

eas.)N

B9°46'55"W

-

265J.67'(M

eas.)85

SOU

TH200

EAST

-

VER

NA

L,U

TAH

840'78(435)

789-1017

LEGEN

D:

SCA

LED

ATE

SUR

VEY

ED:

DA

TED

RA

WN

:1"

=1000°

10-05-0910-20-09

=90°

SYM

BO

LN

AD

83(TA

RG

ETB

OTTO

MH

OLE)

NA

D83

(SUR

FAC

ELO

CA

TION

)PA

RTY

REFER

ENC

ESLA

TITUD

E=

4000'38.79"

(40.010775)LA

TITUD

E=

40°00'44.65"(40.012403)

=PR

OPO

SEDW

ELLH

EAD

.LO

NG

ITUD

E=

109°23'43.41"(109.395392)

LON

GITU

DE

=109°23'42.32"

(109.395089)G

.S.C

.R.

D.R

.B.

G.L.O

.PLA

TN

AD

27(TA

RG

ETB

OTTO

MH

OLE)

NA

D27

(SUR

FAC

ELO

CA

TION

)W

FATH

FRFILE

A=

SECTIO

NC

OR

NER

SLO

CA

TED.

LATITU

DE

=40°00'38.92"

(40.010811)LA

TITUD

E=

40°00'44.77"(40.012436)

LON

GITU

DE

=10923°40.96"

(109.394710)LO

NG

ITUD

E=

10923'39.87"(109.394408)

OO

LEO

GR

ESOU

RC

ES,

Page 5: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

26 April, 2010

Plan: APD

T9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

'APIWellNo:43047511750000''APIWellNo:43047511750000'

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

Plan: APD

Standard Planning Report26 April,

'APIWellNo:43047511750000'

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

Plan: APD

Standard Planning Report26 April,

'APIWellNo:43047511750000'

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

Plan: APD

Standard Planning Report26 April,

'APIWellNo:43047511750000'

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

Plan: APD

Standard Planning Report26 April,

'APIWellNo:43047511750000'

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)1535-25DWellbore #1

Plan: APD

Standard Planning Report26 April,

Page 6: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Project:Company:

Local Co-ordinate Reference:TVD Reference:

Site:

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Se

EOG Resources IncPlanning Report

Well:Wellbore:

1535-25DWellbore #1

Survey Calculation Method: Minimum Curvature

RIG @ 5041.00ft (True 34)

Design: APD

Database: EDM

MD Reference: RIG @ 5041.00ft (True 34)North Reference:

Well 1535-25D

True

Map System:Geo Datum:

Project

Map Zone:

System Datum:US State Plane 1927 (Exact solution)NAD 1927 (NADCON CONUS)

T9S-R22E Sec 25

Utah North 4301

Mean Sea Level

Site Position:From:

Site

Latitude:Longitude:

Position Uncertainty:

Northing:Easting:

Grid Convergence:

CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

ftLat/Long ft

ft

deg1.39Slot Radius: "

-109,759.402,589,948.91

0.00

40° 0' 44.842 N109° 23' 38.861 W

Well

Well PositionLongitude:Latitude:

Easting:Northing:

ft+E/-W+N/-S

Position Uncertainty

ftft

ftGround Level:

1535-25D

ftft

0.000.00

-109,767.262,589,880.72

5,022.00Wellhead Elevation: ft0.00

40° 0' 44.780 N109° 23' 39.739 W

Wellbore

Declination(deg)

Field Strength(nT)

Sample Date Dip Angle(deg)

Wellbore #1

Model NameMagnetics

IGRF200510 9/17/2009 11.24 65.95 52,553

Phase:Version:Audit Notes:

Design APD

PROTOTYPE

Vertical Section: Depth From (TVD)(ft)

+N/-S(ft)

Direction(deg)

+E/-W(ft)

Tie On Depth: 0.00

353.310.000.000.00

Inclination(deg)

Azimuth(deg)

+E/-W(ft)

TFO(deg)

+N/-S(ft)

MeasuredDepth

(ft)

Vertical Depth

(ft)

DoglegRate

(?/100ft)

BuildRate

(?/100ft)

TurnRate

(?/100ft)

Plan Sections

Target

0.000.000.000.000.000.000.000.000.000.000.000.000.000.000.000.00300.000.000.00300.00

353.310.001.501.50-15.17129.271,288.62353.3115.001,300.000.000.000.000.00-52.28445.622,477.35353.3115.002,530.67

180.000.00-1.001.00-75.03639.523,960.280.000.004,030.680.000.000.000.00-75.03639.526,957.000.000.007,027.39 CWU 1535-25D0.000.000.000.00-75.03639.529,325.000.000.009,395.39

4/26/2010 4:00:48PM COMPASS 2003.21 Build 37 Page 2

'APIWellNo:43047511750000''APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Project T9S-R22E Sec 25

Map System: US State Plane 1927 (Exact solution) System Datum: Mean Sea LevelGeo Datum: NAD 1927 (NADCON CONUS)Map Zone: Utah North 4301

Site CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

Site Position: Northing: -109,759.40ft Latitude: 40° O'44.842 NFrom: Lat/Long Easting: 2,589,948.91 ft Longitude: 109° 23' 38.861 WPosition Uncertainty: 0.00 ft Slot Radius: " Grid Convergence: 1.39 deg

Well 1535-25D

Well Position +NI-S 0.00 ft Northing: -109,767.26 ft Latitude: 40° O'44.780 N+El-W 0.00 ft Easting: 2,589,880.72 ft Longitude: 109° 23' 39.739 W

Position Uncertainty 0.00 ft Wellhead Elevation: ft Ground Level: 5,022.00ft

Wellbore Wellbore #1

Magnetics Model Name Sample Date Declination Dip Angle Field Strength(deg) (deg) (nT)

IGRF200510 9/17/2009 11.24 65.95 52,553

Design APD

Audit Notes:Version: Phase: PROTOTYPE Tie On Depth: 0.00

Vertical Section: Depth From (TVD) +NI-S +El-W Direction(ft) (ft) (ft) (deg)

0.00 0.00 0.00 353.31

Plan Sections

Measured Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Rate Rate Rate TFO

(ft) (deg) (deg) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft) (deg) Target

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00

1,300.00 15.00 353.31 1,288.62 129.27 -15.17 1.50 1.50 0.00 353.312,530.67 15.00 353.31 2,477.35 445.62 -52.28 0.00 0.00 0.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 1.00 -1.00 0.00 180.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 0.00 0.00 0.00 0.00 CWU 1535-25D9,395.39 0.00 0.00 9,325.00 639.52 -75.03 0.00 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 2 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Project T9S-R22E Sec 25

Map System: US State Plane 1927 (Exact solution) System Datum: Mean Sea LevelGeo Datum: NAD 1927 (NADCON CONUS)Map Zone: Utah North 4301

Site CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

Site Position: Northing: -109,759.40ft Latitude: 40° O'44.842 NFrom: Lat/Long Easting: 2,589,948.91 ft Longitude: 109° 23' 38.861 WPosition Uncertainty: 0.00 ft Slot Radius: " Grid Convergence: 1.39 deg

Well 1535-25D

Well Position +NI-S 0.00 ft Northing: -109,767.26 ft Latitude: 40° O'44.780 N+El-W 0.00 ft Easting: 2,589,880.72 ft Longitude: 109° 23' 39.739 W

Position Uncertainty 0.00 ft Wellhead Elevation: ft Ground Level: 5,022.00ft

Wellbore Wellbore #1

Magnetics Model Name Sample Date Declination Dip Angle Field Strength(deg) (deg) (nT)

IGRF200510 9/17/2009 11.24 65.95 52,553

Design APD

Audit Notes:Version: Phase: PROTOTYPE Tie On Depth: 0.00

Vertical Section: Depth From (TVD) +NI-S +El-W Direction(ft) (ft) (ft) (deg)

0.00 0.00 0.00 353.31

Plan Sections

Measured Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Rate Rate Rate TFO

(ft) (deg) (deg) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft) (deg) Target

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00

1,300.00 15.00 353.31 1,288.62 129.27 -15.17 1.50 1.50 0.00 353.312,530.67 15.00 353.31 2,477.35 445.62 -52.28 0.00 0.00 0.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 1.00 -1.00 0.00 180.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 0.00 0.00 0.00 0.00 CWU 1535-25D9,395.39 0.00 0.00 9,325.00 639.52 -75.03 0.00 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 2 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Project T9S-R22E Sec 25

Map System: US State Plane 1927 (Exact solution) System Datum: Mean Sea LevelGeo Datum: NAD 1927 (NADCON CONUS)Map Zone: Utah North 4301

Site CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

Site Position: Northing: -109,759.40ft Latitude: 40° O'44.842 NFrom: Lat/Long Easting: 2,589,948.91 ft Longitude: 109° 23' 38.861 WPosition Uncertainty: 0.00 ft Slot Radius: " Grid Convergence: 1.39 deg

Well 1535-25D

Well Position +NI-S 0.00 ft Northing: -109,767.26 ft Latitude: 40° O'44.780 N+El-W 0.00 ft Easting: 2,589,880.72 ft Longitude: 109° 23' 39.739 W

Position Uncertainty 0.00 ft Wellhead Elevation: ft Ground Level: 5,022.00ft

Wellbore Wellbore #1

Magnetics Model Name Sample Date Declination Dip Angle Field Strength(deg) (deg) (nT)

IGRF200510 9/17/2009 11.24 65.95 52,553

Design APD

Audit Notes:Version: Phase: PROTOTYPE Tie On Depth: 0.00

Vertical Section: Depth From (TVD) +NI-S +El-W Direction(ft) (ft) (ft) (deg)

0.00 0.00 0.00 353.31

Plan Sections

Measured Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Rate Rate Rate TFO

(ft) (deg) (deg) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft) (deg) Target

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00

1,300.00 15.00 353.31 1,288.62 129.27 -15.17 1.50 1.50 0.00 353.312,530.67 15.00 353.31 2,477.35 445.62 -52.28 0.00 0.00 0.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 1.00 -1.00 0.00 180.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 0.00 0.00 0.00 0.00 CWU 1535-25D9,395.39 0.00 0.00 9,325.00 639.52 -75.03 0.00 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 2 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Project T9S-R22E Sec 25

Map System: US State Plane 1927 (Exact solution) System Datum: Mean Sea LevelGeo Datum: NAD 1927 (NADCON CONUS)Map Zone: Utah North 4301

Site CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

Site Position: Northing: -109,759.40ft Latitude: 40° O'44.842 NFrom: Lat/Long Easting: 2,589,948.91 ft Longitude: 109° 23' 38.861 WPosition Uncertainty: 0.00 ft Slot Radius: " Grid Convergence: 1.39 deg

Well 1535-25D

Well Position +NI-S 0.00 ft Northing: -109,767.26 ft Latitude: 40° O'44.780 N+El-W 0.00 ft Easting: 2,589,880.72 ft Longitude: 109° 23' 39.739 W

Position Uncertainty 0.00 ft Wellhead Elevation: ft Ground Level: 5,022.00ft

Wellbore Wellbore #1

Magnetics Model Name Sample Date Declination Dip Angle Field Strength(deg) (deg) (nT)

IGRF200510 9/17/2009 11.24 65.95 52,553

Design APD

Audit Notes:Version: Phase: PROTOTYPE Tie On Depth: 0.00

Vertical Section: Depth From (TVD) +NI-S +El-W Direction(ft) (ft) (ft) (deg)

0.00 0.00 0.00 353.31

Plan Sections

Measured Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Rate Rate Rate TFO

(ft) (deg) (deg) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft) (deg) Target

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00

1,300.00 15.00 353.31 1,288.62 129.27 -15.17 1.50 1.50 0.00 353.312,530.67 15.00 353.31 2,477.35 445.62 -52.28 0.00 0.00 0.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 1.00 -1.00 0.00 180.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 0.00 0.00 0.00 0.00 CWU 1535-25D9,395.39 0.00 0.00 9,325.00 639.52 -75.03 0.00 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 2 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Project T9S-R22E Sec 25

Map System: US State Plane 1927 (Exact solution) System Datum: Mean Sea LevelGeo Datum: NAD 1927 (NADCON CONUS)Map Zone: Utah North 4301

Site CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)

Site Position: Northing: -109,759.40ft Latitude: 40° O'44.842 NFrom: Lat/Long Easting: 2,589,948.91 ft Longitude: 109° 23' 38.861 WPosition Uncertainty: 0.00 ft Slot Radius: " Grid Convergence: 1.39 deg

Well 1535-25D

Well Position +NI-S 0.00 ft Northing: -109,767.26 ft Latitude: 40° O'44.780 N+El-W 0.00 ft Easting: 2,589,880.72 ft Longitude: 109° 23' 39.739 W

Position Uncertainty 0.00 ft Wellhead Elevation: ft Ground Level: 5,022.00ft

Wellbore Wellbore #1

Magnetics Model Name Sample Date Declination Dip Angle Field Strength(deg) (deg) (nT)

IGRF200510 9/17/2009 11.24 65.95 52,553

Design APD

Audit Notes:Version: Phase: PROTOTYPE Tie On Depth: 0.00

Vertical Section: Depth From (TVD) +NI-S +El-W Direction(ft) (ft) (ft) (deg)

0.00 0.00 0.00 353.31

Plan Sections

Measured Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Rate Rate Rate TFO

(ft) (deg) (deg) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft) (deg) Target

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00

1,300.00 15.00 353.31 1,288.62 129.27 -15.17 1.50 1.50 0.00 353.312,530.67 15.00 353.31 2,477.35 445.62 -52.28 0.00 0.00 0.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 1.00 -1.00 0.00 180.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 0.00 0.00 0.00 0.00 CWU 1535-25D9,395.39 0.00 0.00 9,325.00 639.52 -75.03 0.00 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 2 COMPASS 2003.21 Build

Page 7: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Project:Company:

Local Co-ordinate Reference:TVD Reference:

Site:

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Se

EOG Resources IncPlanning Report

Well:Wellbore:

1535-25DWellbore #1

Survey Calculation Method: Minimum Curvature

RIG @ 5041.00ft (True 34)

Design: APD

Database: EDM

MD Reference: RIG @ 5041.00ft (True 34)North Reference:

Well 1535-25D

True

MeasuredDepth

(ft)Inclination

(deg)Azimuth

(deg)+E/-W

(ft)

VerticalSection

(ft)

DoglegRate

(?/100ft)+N/-S

(ft)

BuildRate

(?/100ft)

TurnRate

(?/100ft)

Planned Survey

Vertical Depth

(ft)

0.00 0.00 0.00 0.00 0.00 0.000.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.000.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.000.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.000.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.31 1.501.30 -0.15 1.50 0.00

500.00 3.00 353.31 499.91 5.23 1.505.20 -0.61 1.50 0.00600.00 4.50 353.31 599.69 11.77 1.5011.69 -1.37 1.50 0.00700.00 6.00 353.31 699.27 20.92 1.5020.78 -2.44 1.50 0.00800.00 7.50 353.31 798.57 32.68 1.5032.46 -3.81 1.50 0.00900.00 9.00 353.31 897.54 47.03 1.5046.71 -5.48 1.50 0.00

1,000.00 10.50 353.31 996.09 63.96 1.5063.53 -7.45 1.50 0.001,100.00 12.00 353.31 1,094.16 83.47 1.5082.90 -9.73 1.50 0.001,200.00 13.50 353.31 1,191.70 105.54 1.50104.82 -12.30 1.50 0.001,300.00 15.00 353.31 1,288.62 130.15 1.50129.27 -15.17 1.50 0.001,400.00 15.00 353.31 1,385.21 156.04 0.00154.97 -18.18 0.00 0.00

1,500.00 15.00 353.31 1,481.80 181.92 0.00180.68 -21.20 0.00 0.001,600.00 15.00 353.31 1,578.39 207.80 0.00206.38 -24.21 0.00 0.001,700.00 15.00 353.31 1,674.99 233.68 0.00232.09 -27.23 0.00 0.001,800.00 15.00 353.31 1,771.58 259.56 0.00257.79 -30.24 0.00 0.001,900.00 15.00 353.31 1,868.17 285.44 0.00283.50 -33.26 0.00 0.00

2,000.00 15.00 353.31 1,964.76 311.33 0.00309.21 -36.28 0.00 0.002,100.00 15.00 353.31 2,061.36 337.21 0.00334.91 -39.29 0.00 0.002,200.00 15.00 353.31 2,157.95 363.09 0.00360.62 -42.31 0.00 0.002,300.00 15.00 353.31 2,254.54 388.97 0.00386.32 -45.32 0.00 0.002,400.00 15.00 353.31 2,351.13 414.85 0.00412.03 -48.34 0.00 0.00

2,500.00 15.00 353.31 2,447.73 440.74 0.00437.73 -51.35 0.00 0.002,530.67 15.00 353.31 2,477.35 448.67 0.00445.62 -52.28 0.00 0.002,600.00 14.31 353.31 2,544.43 466.21 1.00463.04 -54.32 -1.00 0.002,700.00 13.31 353.31 2,641.54 490.08 1.00486.74 -57.10 -1.00 0.002,800.00 12.31 353.31 2,739.05 512.24 1.00508.75 -59.69 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 532.70 1.00529.08 -62.07 -1.00 0.003,000.00 10.31 353.31 2,935.16 551.45 1.00547.70 -64.26 -1.00 0.003,100.00 9.31 353.31 3,033.69 568.49 1.00564.61 -66.24 -1.00 0.003,200.00 8.31 353.31 3,132.51 583.80 1.00579.82 -68.02 -1.00 0.003,300.00 7.31 353.31 3,231.58 597.38 1.00593.31 -69.61 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 609.23 1.00605.08 -70.99 -1.00 0.003,500.00 5.31 353.31 3,430.36 619.35 1.00615.13 -72.17 -1.00 0.003,600.00 4.31 353.31 3,530.01 627.73 1.00623.45 -73.14 -1.00 0.003,700.00 3.31 353.31 3,629.79 634.37 1.00630.05 -73.92 -1.00 0.003,800.00 2.31 353.31 3,729.67 639.26 1.00634.91 -74.49 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 642.42 1.00638.04 -74.85 -1.00 0.004,000.00 0.31 353.31 3,929.61 643.82 1.00639.44 -75.02 -1.00 0.004,030.68 0.00 0.00 3,960.28 643.91 1.00639.52 -75.03 -1.00 0.004,100.00 0.00 0.00 4,029.61 643.91 0.00639.52 -75.03 0.00 0.004,200.00 0.00 0.00 4,129.61 643.91 0.00639.52 -75.03 0.00 0.00

4,300.00 0.00 0.00 4,229.61 643.91 0.00639.52 -75.03 0.00 0.004,400.00 0.00 0.00 4,329.61 643.91 0.00639.52 -75.03 0.00 0.004,500.00 0.00 0.00 4,429.61 643.91 0.00639.52 -75.03 0.00 0.004,600.00 0.00 0.00 4,529.61 643.91 0.00639.52 -75.03 0.00 0.004,700.00 0.00 0.00 4,629.61 643.91 0.00639.52 -75.03 0.00 0.00

4,800.00 0.00 0.00 4,729.61 643.91 0.00639.52 -75.03 0.00 0.004,900.00 0.00 0.00 4,829.61 643.91 0.00639.52 -75.03 0.00 0.005,000.00 0.00 0.00 4,929.61 643.91 0.00639.52 -75.03 0.00 0.005,100.00 0.00 0.00 5,029.61 643.91 0.00639.52 -75.03 0.00 0.00

4/26/2010 4:00:48PM COMPASS 2003.21 Build 37 Page 3

'APIWellNo:43047511750000''APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.00 0.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.30 -0.15 1.31 1.50 1.50 0.00

500.00 3.00 353.31 499.91 5.20 -0.61 5.23 1.50 1.50 0.00600.00 4.50 353.31 599.69 11.69 -1.37 11.77 1.50 1.50 0.00700.00 6.00 353.31 699.27 20.78 -2.44 20.92 1.50 1.50 0.00800.00 7.50 353.31 798.57 32.46 -3.81 32.68 1.50 1.50 0.00900.00 9.00 353.31 897.54 46.71 -5.48 47.03 1.50 1.50 0.00

1,000.00 10.50 353.31 996.09 63.53 -7.45 63.96 1.50 1.50 0.001,100.00 12.00 353.31 1,094.16 82.90 -9.73 83.47 1.50 1.50 0.001,200.00 13.50 353.31 1,191.70 104.82 -12.30 105.54 1.50 1.50 0.001,300.00 15.00 353.31 1,288.62 129.27 -15.17 130.15 1.50 1.50 0.001,400.00 15.00 353.31 1,385.21 154.97 -18.18 156.04 0.00 0.00 0.00

1,500.00 15.00 353.31 1,481.80 180.68 -21.20 181.92 0.00 0.00 0.001,600.00 15.00 353.31 1,578.39 206.38 -24.21 207.80 0.00 0.00 0.001,700.00 15.00 353.31 1,674.99 232.09 -27.23 233.68 0.00 0.00 0.001,800.00 15.00 353.31 1,771.58 257.79 -30.24 259.56 0.00 0.00 0.001,900.00 15.00 353.31 1,868.17 283.50 -33.26 285.44 0.00 0.00 0.00

2,000.00 15.00 353.31 1,964.76 309.21 -36.28 311.33 0.00 0.00 0.002,100.00 15.00 353.31 2,061.36 334.91 -39.29 337.21 0.00 0.00 0.002,200.00 15.00 353.31 2,157.95 360.62 -42.31 363.09 0.00 0.00 0.002,300.00 15.00 353.31 2,254.54 386.32 -45.32 388.97 0.00 0.00 0.002,400.00 15.00 353.31 2,351.13 412.03 -48.34 414.85 0.00 0.00 0.00

2,500.00 15.00 353.31 2,447.73 437.73 -51.35 440.74 0.00 0.00 0.002,530.67 15.00 353.31 2,477.35 445.62 -52.28 448.67 0.00 0.00 0.002,600.00 14.31 353.31 2,544.43 463.04 -54.32 466.21 1.00 -1.00 0.002,700.00 13.31 353.31 2,641.54 486.74 -57.10 490.08 1.00 -1.00 0.002,800.00 12.31 353.31 2,739.05 508.75 -59.69 512.24 1.00 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 529.08 -62.07 532.70 1.00 -1.00 0.003,000.00 10.31 353.31 2,935.16 547.70 -64.26 551.45 1.00 -1.00 0.003,100.00 9.31 353.31 3,033.69 564.61 -66.24 568.49 1.00 -1.00 0.003,200.00 8.31 353.31 3,132.51 579.82 -68.02 583.80 1.00 -1.00 0.003,300.00 7.31 353.31 3,231.58 593.31 -69.61 597.38 1.00 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 605.08 -70.99 609.23 1.00 -1.00 0.003,500.00 5.31 353.31 3,430.36 615.13 -72.17 619.35 1.00 -1.00 0.003,600.00 4.31 353.31 3,530.01 623.45 -73.14 627.73 1.00 -1.00 0.003,700.00 3.31 353.31 3,629.79 630.05 -73.92 634.37 1.00 -1.00 0.003,800.00 2.31 353.31 3,729.67 634.91 -74.49 639.26 1.00 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 638.04 -74.85 642.42 1.00 -1.00 0.004,000.00 0.31 353.31 3,929.61 639.44 -75.02 643.82 1.00 -1.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 643.91 1.00 -1.00 0.004,100.00 0.00 0.00 4,029.61 639.52 -75.03 643.91 0.00 0.00 0.004,200.00 0.00 0.00 4,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,300.00 0.00 0.00 4,229.61 639.52 -75.03 643.91 0.00 0.00 0.004,400.00 0.00 0.00 4,329.61 639.52 -75.03 643.91 0.00 0.00 0.004,500.00 0.00 0.00 4,429.61 639.52 -75.03 643.91 0.00 0.00 0.004,600.00 0.00 0.00 4,529.61 639.52 -75.03 643.91 0.00 0.00 0.004,700.00 0.00 0.00 4,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,800.00 0.00 0.00 4,729.61 639.52 -75.03 643.91 0.00 0.00 0.004,900.00 0.00 0.00 4,829.61 639.52 -75.03 643.91 0.00 0.00 0.005,000.00 0.00 0.00 4,929.61 639.52 -75.03 643.91 0.00 0.00 0.005,100.00 0.00 0.00 5,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 3 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.00 0.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.30 -0.15 1.31 1.50 1.50 0.00

500.00 3.00 353.31 499.91 5.20 -0.61 5.23 1.50 1.50 0.00600.00 4.50 353.31 599.69 11.69 -1.37 11.77 1.50 1.50 0.00700.00 6.00 353.31 699.27 20.78 -2.44 20.92 1.50 1.50 0.00800.00 7.50 353.31 798.57 32.46 -3.81 32.68 1.50 1.50 0.00900.00 9.00 353.31 897.54 46.71 -5.48 47.03 1.50 1.50 0.00

1,000.00 10.50 353.31 996.09 63.53 -7.45 63.96 1.50 1.50 0.001,100.00 12.00 353.31 1,094.16 82.90 -9.73 83.47 1.50 1.50 0.001,200.00 13.50 353.31 1,191.70 104.82 -12.30 105.54 1.50 1.50 0.001,300.00 15.00 353.31 1,288.62 129.27 -15.17 130.15 1.50 1.50 0.001,400.00 15.00 353.31 1,385.21 154.97 -18.18 156.04 0.00 0.00 0.00

1,500.00 15.00 353.31 1,481.80 180.68 -21.20 181.92 0.00 0.00 0.001,600.00 15.00 353.31 1,578.39 206.38 -24.21 207.80 0.00 0.00 0.001,700.00 15.00 353.31 1,674.99 232.09 -27.23 233.68 0.00 0.00 0.001,800.00 15.00 353.31 1,771.58 257.79 -30.24 259.56 0.00 0.00 0.001,900.00 15.00 353.31 1,868.17 283.50 -33.26 285.44 0.00 0.00 0.00

2,000.00 15.00 353.31 1,964.76 309.21 -36.28 311.33 0.00 0.00 0.002,100.00 15.00 353.31 2,061.36 334.91 -39.29 337.21 0.00 0.00 0.002,200.00 15.00 353.31 2,157.95 360.62 -42.31 363.09 0.00 0.00 0.002,300.00 15.00 353.31 2,254.54 386.32 -45.32 388.97 0.00 0.00 0.002,400.00 15.00 353.31 2,351.13 412.03 -48.34 414.85 0.00 0.00 0.00

2,500.00 15.00 353.31 2,447.73 437.73 -51.35 440.74 0.00 0.00 0.002,530.67 15.00 353.31 2,477.35 445.62 -52.28 448.67 0.00 0.00 0.002,600.00 14.31 353.31 2,544.43 463.04 -54.32 466.21 1.00 -1.00 0.002,700.00 13.31 353.31 2,641.54 486.74 -57.10 490.08 1.00 -1.00 0.002,800.00 12.31 353.31 2,739.05 508.75 -59.69 512.24 1.00 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 529.08 -62.07 532.70 1.00 -1.00 0.003,000.00 10.31 353.31 2,935.16 547.70 -64.26 551.45 1.00 -1.00 0.003,100.00 9.31 353.31 3,033.69 564.61 -66.24 568.49 1.00 -1.00 0.003,200.00 8.31 353.31 3,132.51 579.82 -68.02 583.80 1.00 -1.00 0.003,300.00 7.31 353.31 3,231.58 593.31 -69.61 597.38 1.00 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 605.08 -70.99 609.23 1.00 -1.00 0.003,500.00 5.31 353.31 3,430.36 615.13 -72.17 619.35 1.00 -1.00 0.003,600.00 4.31 353.31 3,530.01 623.45 -73.14 627.73 1.00 -1.00 0.003,700.00 3.31 353.31 3,629.79 630.05 -73.92 634.37 1.00 -1.00 0.003,800.00 2.31 353.31 3,729.67 634.91 -74.49 639.26 1.00 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 638.04 -74.85 642.42 1.00 -1.00 0.004,000.00 0.31 353.31 3,929.61 639.44 -75.02 643.82 1.00 -1.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 643.91 1.00 -1.00 0.004,100.00 0.00 0.00 4,029.61 639.52 -75.03 643.91 0.00 0.00 0.004,200.00 0.00 0.00 4,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,300.00 0.00 0.00 4,229.61 639.52 -75.03 643.91 0.00 0.00 0.004,400.00 0.00 0.00 4,329.61 639.52 -75.03 643.91 0.00 0.00 0.004,500.00 0.00 0.00 4,429.61 639.52 -75.03 643.91 0.00 0.00 0.004,600.00 0.00 0.00 4,529.61 639.52 -75.03 643.91 0.00 0.00 0.004,700.00 0.00 0.00 4,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,800.00 0.00 0.00 4,729.61 639.52 -75.03 643.91 0.00 0.00 0.004,900.00 0.00 0.00 4,829.61 639.52 -75.03 643.91 0.00 0.00 0.005,000.00 0.00 0.00 4,929.61 639.52 -75.03 643.91 0.00 0.00 0.005,100.00 0.00 0.00 5,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 3 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.00 0.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.30 -0.15 1.31 1.50 1.50 0.00

500.00 3.00 353.31 499.91 5.20 -0.61 5.23 1.50 1.50 0.00600.00 4.50 353.31 599.69 11.69 -1.37 11.77 1.50 1.50 0.00700.00 6.00 353.31 699.27 20.78 -2.44 20.92 1.50 1.50 0.00800.00 7.50 353.31 798.57 32.46 -3.81 32.68 1.50 1.50 0.00900.00 9.00 353.31 897.54 46.71 -5.48 47.03 1.50 1.50 0.00

1,000.00 10.50 353.31 996.09 63.53 -7.45 63.96 1.50 1.50 0.001,100.00 12.00 353.31 1,094.16 82.90 -9.73 83.47 1.50 1.50 0.001,200.00 13.50 353.31 1,191.70 104.82 -12.30 105.54 1.50 1.50 0.001,300.00 15.00 353.31 1,288.62 129.27 -15.17 130.15 1.50 1.50 0.001,400.00 15.00 353.31 1,385.21 154.97 -18.18 156.04 0.00 0.00 0.00

1,500.00 15.00 353.31 1,481.80 180.68 -21.20 181.92 0.00 0.00 0.001,600.00 15.00 353.31 1,578.39 206.38 -24.21 207.80 0.00 0.00 0.001,700.00 15.00 353.31 1,674.99 232.09 -27.23 233.68 0.00 0.00 0.001,800.00 15.00 353.31 1,771.58 257.79 -30.24 259.56 0.00 0.00 0.001,900.00 15.00 353.31 1,868.17 283.50 -33.26 285.44 0.00 0.00 0.00

2,000.00 15.00 353.31 1,964.76 309.21 -36.28 311.33 0.00 0.00 0.002,100.00 15.00 353.31 2,061.36 334.91 -39.29 337.21 0.00 0.00 0.002,200.00 15.00 353.31 2,157.95 360.62 -42.31 363.09 0.00 0.00 0.002,300.00 15.00 353.31 2,254.54 386.32 -45.32 388.97 0.00 0.00 0.002,400.00 15.00 353.31 2,351.13 412.03 -48.34 414.85 0.00 0.00 0.00

2,500.00 15.00 353.31 2,447.73 437.73 -51.35 440.74 0.00 0.00 0.002,530.67 15.00 353.31 2,477.35 445.62 -52.28 448.67 0.00 0.00 0.002,600.00 14.31 353.31 2,544.43 463.04 -54.32 466.21 1.00 -1.00 0.002,700.00 13.31 353.31 2,641.54 486.74 -57.10 490.08 1.00 -1.00 0.002,800.00 12.31 353.31 2,739.05 508.75 -59.69 512.24 1.00 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 529.08 -62.07 532.70 1.00 -1.00 0.003,000.00 10.31 353.31 2,935.16 547.70 -64.26 551.45 1.00 -1.00 0.003,100.00 9.31 353.31 3,033.69 564.61 -66.24 568.49 1.00 -1.00 0.003,200.00 8.31 353.31 3,132.51 579.82 -68.02 583.80 1.00 -1.00 0.003,300.00 7.31 353.31 3,231.58 593.31 -69.61 597.38 1.00 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 605.08 -70.99 609.23 1.00 -1.00 0.003,500.00 5.31 353.31 3,430.36 615.13 -72.17 619.35 1.00 -1.00 0.003,600.00 4.31 353.31 3,530.01 623.45 -73.14 627.73 1.00 -1.00 0.003,700.00 3.31 353.31 3,629.79 630.05 -73.92 634.37 1.00 -1.00 0.003,800.00 2.31 353.31 3,729.67 634.91 -74.49 639.26 1.00 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 638.04 -74.85 642.42 1.00 -1.00 0.004,000.00 0.31 353.31 3,929.61 639.44 -75.02 643.82 1.00 -1.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 643.91 1.00 -1.00 0.004,100.00 0.00 0.00 4,029.61 639.52 -75.03 643.91 0.00 0.00 0.004,200.00 0.00 0.00 4,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,300.00 0.00 0.00 4,229.61 639.52 -75.03 643.91 0.00 0.00 0.004,400.00 0.00 0.00 4,329.61 639.52 -75.03 643.91 0.00 0.00 0.004,500.00 0.00 0.00 4,429.61 639.52 -75.03 643.91 0.00 0.00 0.004,600.00 0.00 0.00 4,529.61 639.52 -75.03 643.91 0.00 0.00 0.004,700.00 0.00 0.00 4,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,800.00 0.00 0.00 4,729.61 639.52 -75.03 643.91 0.00 0.00 0.004,900.00 0.00 0.00 4,829.61 639.52 -75.03 643.91 0.00 0.00 0.005,000.00 0.00 0.00 4,929.61 639.52 -75.03 643.91 0.00 0.00 0.005,100.00 0.00 0.00 5,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 3 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.00 0.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.30 -0.15 1.31 1.50 1.50 0.00

500.00 3.00 353.31 499.91 5.20 -0.61 5.23 1.50 1.50 0.00600.00 4.50 353.31 599.69 11.69 -1.37 11.77 1.50 1.50 0.00700.00 6.00 353.31 699.27 20.78 -2.44 20.92 1.50 1.50 0.00800.00 7.50 353.31 798.57 32.46 -3.81 32.68 1.50 1.50 0.00900.00 9.00 353.31 897.54 46.71 -5.48 47.03 1.50 1.50 0.00

1,000.00 10.50 353.31 996.09 63.53 -7.45 63.96 1.50 1.50 0.001,100.00 12.00 353.31 1,094.16 82.90 -9.73 83.47 1.50 1.50 0.001,200.00 13.50 353.31 1,191.70 104.82 -12.30 105.54 1.50 1.50 0.001,300.00 15.00 353.31 1,288.62 129.27 -15.17 130.15 1.50 1.50 0.001,400.00 15.00 353.31 1,385.21 154.97 -18.18 156.04 0.00 0.00 0.00

1,500.00 15.00 353.31 1,481.80 180.68 -21.20 181.92 0.00 0.00 0.001,600.00 15.00 353.31 1,578.39 206.38 -24.21 207.80 0.00 0.00 0.001,700.00 15.00 353.31 1,674.99 232.09 -27.23 233.68 0.00 0.00 0.001,800.00 15.00 353.31 1,771.58 257.79 -30.24 259.56 0.00 0.00 0.001,900.00 15.00 353.31 1,868.17 283.50 -33.26 285.44 0.00 0.00 0.00

2,000.00 15.00 353.31 1,964.76 309.21 -36.28 311.33 0.00 0.00 0.002,100.00 15.00 353.31 2,061.36 334.91 -39.29 337.21 0.00 0.00 0.002,200.00 15.00 353.31 2,157.95 360.62 -42.31 363.09 0.00 0.00 0.002,300.00 15.00 353.31 2,254.54 386.32 -45.32 388.97 0.00 0.00 0.002,400.00 15.00 353.31 2,351.13 412.03 -48.34 414.85 0.00 0.00 0.00

2,500.00 15.00 353.31 2,447.73 437.73 -51.35 440.74 0.00 0.00 0.002,530.67 15.00 353.31 2,477.35 445.62 -52.28 448.67 0.00 0.00 0.002,600.00 14.31 353.31 2,544.43 463.04 -54.32 466.21 1.00 -1.00 0.002,700.00 13.31 353.31 2,641.54 486.74 -57.10 490.08 1.00 -1.00 0.002,800.00 12.31 353.31 2,739.05 508.75 -59.69 512.24 1.00 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 529.08 -62.07 532.70 1.00 -1.00 0.003,000.00 10.31 353.31 2,935.16 547.70 -64.26 551.45 1.00 -1.00 0.003,100.00 9.31 353.31 3,033.69 564.61 -66.24 568.49 1.00 -1.00 0.003,200.00 8.31 353.31 3,132.51 579.82 -68.02 583.80 1.00 -1.00 0.003,300.00 7.31 353.31 3,231.58 593.31 -69.61 597.38 1.00 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 605.08 -70.99 609.23 1.00 -1.00 0.003,500.00 5.31 353.31 3,430.36 615.13 -72.17 619.35 1.00 -1.00 0.003,600.00 4.31 353.31 3,530.01 623.45 -73.14 627.73 1.00 -1.00 0.003,700.00 3.31 353.31 3,629.79 630.05 -73.92 634.37 1.00 -1.00 0.003,800.00 2.31 353.31 3,729.67 634.91 -74.49 639.26 1.00 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 638.04 -74.85 642.42 1.00 -1.00 0.004,000.00 0.31 353.31 3,929.61 639.44 -75.02 643.82 1.00 -1.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 643.91 1.00 -1.00 0.004,100.00 0.00 0.00 4,029.61 639.52 -75.03 643.91 0.00 0.00 0.004,200.00 0.00 0.00 4,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,300.00 0.00 0.00 4,229.61 639.52 -75.03 643.91 0.00 0.00 0.004,400.00 0.00 0.00 4,329.61 639.52 -75.03 643.91 0.00 0.00 0.004,500.00 0.00 0.00 4,429.61 639.52 -75.03 643.91 0.00 0.00 0.004,600.00 0.00 0.00 4,529.61 639.52 -75.03 643.91 0.00 0.00 0.004,700.00 0.00 0.00 4,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,800.00 0.00 0.00 4,729.61 639.52 -75.03 643.91 0.00 0.00 0.004,900.00 0.00 0.00 4,829.61 639.52 -75.03 643.91 0.00 0.00 0.005,000.00 0.00 0.00 4,929.61 639.52 -75.03 643.91 0.00 0.00 0.005,100.00 0.00 0.00 5,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 3 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00100.00 0.00 0.00 100.00 0.00 0.00 0.00 0.00 0.00 0.00200.00 0.00 0.00 200.00 0.00 0.00 0.00 0.00 0.00 0.00300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.00 0.00400.00 1.50 353.31 399.99 1.30 -0.15 1.31 1.50 1.50 0.00

500.00 3.00 353.31 499.91 5.20 -0.61 5.23 1.50 1.50 0.00600.00 4.50 353.31 599.69 11.69 -1.37 11.77 1.50 1.50 0.00700.00 6.00 353.31 699.27 20.78 -2.44 20.92 1.50 1.50 0.00800.00 7.50 353.31 798.57 32.46 -3.81 32.68 1.50 1.50 0.00900.00 9.00 353.31 897.54 46.71 -5.48 47.03 1.50 1.50 0.00

1,000.00 10.50 353.31 996.09 63.53 -7.45 63.96 1.50 1.50 0.001,100.00 12.00 353.31 1,094.16 82.90 -9.73 83.47 1.50 1.50 0.001,200.00 13.50 353.31 1,191.70 104.82 -12.30 105.54 1.50 1.50 0.001,300.00 15.00 353.31 1,288.62 129.27 -15.17 130.15 1.50 1.50 0.001,400.00 15.00 353.31 1,385.21 154.97 -18.18 156.04 0.00 0.00 0.00

1,500.00 15.00 353.31 1,481.80 180.68 -21.20 181.92 0.00 0.00 0.001,600.00 15.00 353.31 1,578.39 206.38 -24.21 207.80 0.00 0.00 0.001,700.00 15.00 353.31 1,674.99 232.09 -27.23 233.68 0.00 0.00 0.001,800.00 15.00 353.31 1,771.58 257.79 -30.24 259.56 0.00 0.00 0.001,900.00 15.00 353.31 1,868.17 283.50 -33.26 285.44 0.00 0.00 0.00

2,000.00 15.00 353.31 1,964.76 309.21 -36.28 311.33 0.00 0.00 0.002,100.00 15.00 353.31 2,061.36 334.91 -39.29 337.21 0.00 0.00 0.002,200.00 15.00 353.31 2,157.95 360.62 -42.31 363.09 0.00 0.00 0.002,300.00 15.00 353.31 2,254.54 386.32 -45.32 388.97 0.00 0.00 0.002,400.00 15.00 353.31 2,351.13 412.03 -48.34 414.85 0.00 0.00 0.00

2,500.00 15.00 353.31 2,447.73 437.73 -51.35 440.74 0.00 0.00 0.002,530.67 15.00 353.31 2,477.35 445.62 -52.28 448.67 0.00 0.00 0.002,600.00 14.31 353.31 2,544.43 463.04 -54.32 466.21 1.00 -1.00 0.002,700.00 13.31 353.31 2,641.54 486.74 -57.10 490.08 1.00 -1.00 0.002,800.00 12.31 353.31 2,739.05 508.75 -59.69 512.24 1.00 -1.00 0.00

2,900.00 11.31 353.31 2,836.93 529.08 -62.07 532.70 1.00 -1.00 0.003,000.00 10.31 353.31 2,935.16 547.70 -64.26 551.45 1.00 -1.00 0.003,100.00 9.31 353.31 3,033.69 564.61 -66.24 568.49 1.00 -1.00 0.003,200.00 8.31 353.31 3,132.51 579.82 -68.02 583.80 1.00 -1.00 0.003,300.00 7.31 353.31 3,231.58 593.31 -69.61 597.38 1.00 -1.00 0.00

3,400.00 6.31 353.31 3,330.88 605.08 -70.99 609.23 1.00 -1.00 0.003,500.00 5.31 353.31 3,430.36 615.13 -72.17 619.35 1.00 -1.00 0.003,600.00 4.31 353.31 3,530.01 623.45 -73.14 627.73 1.00 -1.00 0.003,700.00 3.31 353.31 3,629.79 630.05 -73.92 634.37 1.00 -1.00 0.003,800.00 2.31 353.31 3,729.67 634.91 -74.49 639.26 1.00 -1.00 0.00

3,900.00 1.31 353.31 3,829.62 638.04 -74.85 642.42 1.00 -1.00 0.004,000.00 0.31 353.31 3,929.61 639.44 -75.02 643.82 1.00 -1.00 0.004,030.68 0.00 0.00 3,960.28 639.52 -75.03 643.91 1.00 -1.00 0.004,100.00 0.00 0.00 4,029.61 639.52 -75.03 643.91 0.00 0.00 0.004,200.00 0.00 0.00 4,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,300.00 0.00 0.00 4,229.61 639.52 -75.03 643.91 0.00 0.00 0.004,400.00 0.00 0.00 4,329.61 639.52 -75.03 643.91 0.00 0.00 0.004,500.00 0.00 0.00 4,429.61 639.52 -75.03 643.91 0.00 0.00 0.004,600.00 0.00 0.00 4,529.61 639.52 -75.03 643.91 0.00 0.00 0.004,700.00 0.00 0.00 4,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

4,800.00 0.00 0.00 4,729.61 639.52 -75.03 643.91 0.00 0.00 0.004,900.00 0.00 0.00 4,829.61 639.52 -75.03 643.91 0.00 0.00 0.005,000.00 0.00 0.00 4,929.61 639.52 -75.03 643.91 0.00 0.00 0.005,100.00 0.00 0.00 5,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 3 COMPASS 2003.21 Build

Page 8: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Project:Company:

Local Co-ordinate Reference:TVD Reference:

Site:

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Se

EOG Resources IncPlanning Report

Well:Wellbore:

1535-25DWellbore #1

Survey Calculation Method: Minimum Curvature

RIG @ 5041.00ft (True 34)

Design: APD

Database: EDM

MD Reference: RIG @ 5041.00ft (True 34)North Reference:

Well 1535-25D

True

MeasuredDepth

(ft)Inclination

(deg)Azimuth

(deg)+E/-W

(ft)

VerticalSection

(ft)

DoglegRate

(?/100ft)+N/-S

(ft)

BuildRate

(?/100ft)

TurnRate

(?/100ft)

Planned Survey

Vertical Depth

(ft)

5,200.00 0.00 0.00 5,129.61 643.91 0.00639.52 -75.03 0.00 0.00

5,300.00 0.00 0.00 5,229.61 643.91 0.00639.52 -75.03 0.00 0.005,400.00 0.00 0.00 5,329.61 643.91 0.00639.52 -75.03 0.00 0.005,500.00 0.00 0.00 5,429.61 643.91 0.00639.52 -75.03 0.00 0.005,600.00 0.00 0.00 5,529.61 643.91 0.00639.52 -75.03 0.00 0.005,700.00 0.00 0.00 5,629.61 643.91 0.00639.52 -75.03 0.00 0.00

5,800.00 0.00 0.00 5,729.61 643.91 0.00639.52 -75.03 0.00 0.005,900.00 0.00 0.00 5,829.61 643.91 0.00639.52 -75.03 0.00 0.006,000.00 0.00 0.00 5,929.61 643.91 0.00639.52 -75.03 0.00 0.006,100.00 0.00 0.00 6,029.61 643.91 0.00639.52 -75.03 0.00 0.006,200.00 0.00 0.00 6,129.61 643.91 0.00639.52 -75.03 0.00 0.00

6,300.00 0.00 0.00 6,229.61 643.91 0.00639.52 -75.03 0.00 0.006,400.00 0.00 0.00 6,329.61 643.91 0.00639.52 -75.03 0.00 0.006,500.00 0.00 0.00 6,429.61 643.91 0.00639.52 -75.03 0.00 0.006,600.00 0.00 0.00 6,529.61 643.91 0.00639.52 -75.03 0.00 0.006,700.00 0.00 0.00 6,629.61 643.91 0.00639.52 -75.03 0.00 0.00

6,800.00 0.00 0.00 6,729.61 643.91 0.00639.52 -75.03 0.00 0.006,900.00 0.00 0.00 6,829.61 643.91 0.00639.52 -75.03 0.00 0.007,000.00 0.00 0.00 6,929.61 643.91 0.00639.52 -75.03 0.00 0.007,027.39 0.00 0.00 6,957.00 643.91 0.00639.52 -75.03 0.00 0.007,100.00 0.00 0.00 7,029.61 643.91 0.00639.52 -75.03 0.00 0.00

7,200.00 0.00 0.00 7,129.61 643.91 0.00639.52 -75.03 0.00 0.007,300.00 0.00 0.00 7,229.61 643.91 0.00639.52 -75.03 0.00 0.007,400.00 0.00 0.00 7,329.61 643.91 0.00639.52 -75.03 0.00 0.007,500.00 0.00 0.00 7,429.61 643.91 0.00639.52 -75.03 0.00 0.007,600.00 0.00 0.00 7,529.61 643.91 0.00639.52 -75.03 0.00 0.00

7,700.00 0.00 0.00 7,629.61 643.91 0.00639.52 -75.03 0.00 0.007,800.00 0.00 0.00 7,729.61 643.91 0.00639.52 -75.03 0.00 0.007,900.00 0.00 0.00 7,829.61 643.91 0.00639.52 -75.03 0.00 0.008,000.00 0.00 0.00 7,929.61 643.91 0.00639.52 -75.03 0.00 0.008,100.00 0.00 0.00 8,029.61 643.91 0.00639.52 -75.03 0.00 0.00

8,200.00 0.00 0.00 8,129.61 643.91 0.00639.52 -75.03 0.00 0.008,300.00 0.00 0.00 8,229.61 643.91 0.00639.52 -75.03 0.00 0.008,400.00 0.00 0.00 8,329.61 643.91 0.00639.52 -75.03 0.00 0.008,500.00 0.00 0.00 8,429.61 643.91 0.00639.52 -75.03 0.00 0.008,600.00 0.00 0.00 8,529.61 643.91 0.00639.52 -75.03 0.00 0.00

8,700.00 0.00 0.00 8,629.61 643.91 0.00639.52 -75.03 0.00 0.008,800.00 0.00 0.00 8,729.61 643.91 0.00639.52 -75.03 0.00 0.008,900.00 0.00 0.00 8,829.61 643.91 0.00639.52 -75.03 0.00 0.009,000.00 0.00 0.00 8,929.61 643.91 0.00639.52 -75.03 0.00 0.009,100.00 0.00 0.00 9,029.61 643.91 0.00639.52 -75.03 0.00 0.00

9,200.00 0.00 0.00 9,129.61 643.91 0.00639.52 -75.03 0.00 0.009,300.00 0.00 0.00 9,229.61 643.91 0.00639.52 -75.03 0.00 0.009,395.39 0.00 0.00 9,325.00 643.91 0.00639.52 -75.03 0.00 0.00

4/26/2010 4:00:48PM COMPASS 2003.21 Build 37 Page 4

'APIWellNo:43047511750000''APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

5,200.00 0.00 0.00 5,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,300.00 0.00 0.00 5,229.61 639.52 -75.03 643.91 0.00 0.00 0.005,400.00 0.00 0.00 5,329.61 639.52 -75.03 643.91 0.00 0.00 0.005,500.00 0.00 0.00 5,429.61 639.52 -75.03 643.91 0.00 0.00 0.005,600.00 0.00 0.00 5,529.61 639.52 -75.03 643.91 0.00 0.00 0.005,700.00 0.00 0.00 5,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,800.00 0.00 0.00 5,729.61 639.52 -75.03 643.91 0.00 0.00 0.005,900.00 0.00 0.00 5,829.61 639.52 -75.03 643.91 0.00 0.00 0.006,000.00 0.00 0.00 5,929.61 639.52 -75.03 643.91 0.00 0.00 0.006,100.00 0.00 0.00 6,029.61 639.52 -75.03 643.91 0.00 0.00 0.006,200.00 0.00 0.00 6,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,300.00 0.00 0.00 6,229.61 639.52 -75.03 643.91 0.00 0.00 0.006,400.00 0.00 0.00 6,329.61 639.52 -75.03 643.91 0.00 0.00 0.006,500.00 0.00 0.00 6,429.61 639.52 -75.03 643.91 0.00 0.00 0.006,600.00 0.00 0.00 6,529.61 639.52 -75.03 643.91 0.00 0.00 0.006,700.00 0.00 0.00 6,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,800.00 0.00 0.00 6,729.61 639.52 -75.03 643.91 0.00 0.00 0.006,900.00 0.00 0.00 6,829.61 639.52 -75.03 643.91 0.00 0.00 0.007,000.00 0.00 0.00 6,929.61 639.52 -75.03 643.91 0.00 0.00 0.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 643.91 0.00 0.00 0.007,100.00 0.00 0.00 7,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,200.00 0.00 0.00 7,129.61 639.52 -75.03 643.91 0.00 0.00 0.007,300.00 0.00 0.00 7,229.61 639.52 -75.03 643.91 0.00 0.00 0.007,400.00 0.00 0.00 7,329.61 639.52 -75.03 643.91 0.00 0.00 0.007,500.00 0.00 0.00 7,429.61 639.52 -75.03 643.91 0.00 0.00 0.007,600.00 0.00 0.00 7,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,700.00 0.00 0.00 7,629.61 639.52 -75.03 643.91 0.00 0.00 0.007,800.00 0.00 0.00 7,729.61 639.52 -75.03 643.91 0.00 0.00 0.007,900.00 0.00 0.00 7,829.61 639.52 -75.03 643.91 0.00 0.00 0.008,000.00 0.00 0.00 7,929.61 639.52 -75.03 643.91 0.00 0.00 0.008,100.00 0.00 0.00 8,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,200.00 0.00 0.00 8,129.61 639.52 -75.03 643.91 0.00 0.00 0.008,300.00 0.00 0.00 8,229.61 639.52 -75.03 643.91 0.00 0.00 0.008,400.00 0.00 0.00 8,329.61 639.52 -75.03 643.91 0.00 0.00 0.008,500.00 0.00 0.00 8,429.61 639.52 -75.03 643.91 0.00 0.00 0.008,600.00 0.00 0.00 8,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,700.00 0.00 0.00 8,629.61 639.52 -75.03 643.91 0.00 0.00 0.008,800.00 0.00 0.00 8,729.61 639.52 -75.03 643.91 0.00 0.00 0.008,900.00 0.00 0.00 8,829.61 639.52 -75.03 643.91 0.00 0.00 0.009,000.00 0.00 0.00 8,929.61 639.52 -75.03 643.91 0.00 0.00 0.009,100.00 0.00 0.00 9,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

9,200.00 0.00 0.00 9,129.61 639.52 -75.03 643.91 0.00 0.00 0.009,300.00 0.00 0.00 9,229.61 639.52 -75.03 643.91 0.00 0.00 0.009,395.39 0.00 0.00 9,325.00 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 4 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

5,200.00 0.00 0.00 5,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,300.00 0.00 0.00 5,229.61 639.52 -75.03 643.91 0.00 0.00 0.005,400.00 0.00 0.00 5,329.61 639.52 -75.03 643.91 0.00 0.00 0.005,500.00 0.00 0.00 5,429.61 639.52 -75.03 643.91 0.00 0.00 0.005,600.00 0.00 0.00 5,529.61 639.52 -75.03 643.91 0.00 0.00 0.005,700.00 0.00 0.00 5,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,800.00 0.00 0.00 5,729.61 639.52 -75.03 643.91 0.00 0.00 0.005,900.00 0.00 0.00 5,829.61 639.52 -75.03 643.91 0.00 0.00 0.006,000.00 0.00 0.00 5,929.61 639.52 -75.03 643.91 0.00 0.00 0.006,100.00 0.00 0.00 6,029.61 639.52 -75.03 643.91 0.00 0.00 0.006,200.00 0.00 0.00 6,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,300.00 0.00 0.00 6,229.61 639.52 -75.03 643.91 0.00 0.00 0.006,400.00 0.00 0.00 6,329.61 639.52 -75.03 643.91 0.00 0.00 0.006,500.00 0.00 0.00 6,429.61 639.52 -75.03 643.91 0.00 0.00 0.006,600.00 0.00 0.00 6,529.61 639.52 -75.03 643.91 0.00 0.00 0.006,700.00 0.00 0.00 6,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,800.00 0.00 0.00 6,729.61 639.52 -75.03 643.91 0.00 0.00 0.006,900.00 0.00 0.00 6,829.61 639.52 -75.03 643.91 0.00 0.00 0.007,000.00 0.00 0.00 6,929.61 639.52 -75.03 643.91 0.00 0.00 0.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 643.91 0.00 0.00 0.007,100.00 0.00 0.00 7,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,200.00 0.00 0.00 7,129.61 639.52 -75.03 643.91 0.00 0.00 0.007,300.00 0.00 0.00 7,229.61 639.52 -75.03 643.91 0.00 0.00 0.007,400.00 0.00 0.00 7,329.61 639.52 -75.03 643.91 0.00 0.00 0.007,500.00 0.00 0.00 7,429.61 639.52 -75.03 643.91 0.00 0.00 0.007,600.00 0.00 0.00 7,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,700.00 0.00 0.00 7,629.61 639.52 -75.03 643.91 0.00 0.00 0.007,800.00 0.00 0.00 7,729.61 639.52 -75.03 643.91 0.00 0.00 0.007,900.00 0.00 0.00 7,829.61 639.52 -75.03 643.91 0.00 0.00 0.008,000.00 0.00 0.00 7,929.61 639.52 -75.03 643.91 0.00 0.00 0.008,100.00 0.00 0.00 8,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,200.00 0.00 0.00 8,129.61 639.52 -75.03 643.91 0.00 0.00 0.008,300.00 0.00 0.00 8,229.61 639.52 -75.03 643.91 0.00 0.00 0.008,400.00 0.00 0.00 8,329.61 639.52 -75.03 643.91 0.00 0.00 0.008,500.00 0.00 0.00 8,429.61 639.52 -75.03 643.91 0.00 0.00 0.008,600.00 0.00 0.00 8,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,700.00 0.00 0.00 8,629.61 639.52 -75.03 643.91 0.00 0.00 0.008,800.00 0.00 0.00 8,729.61 639.52 -75.03 643.91 0.00 0.00 0.008,900.00 0.00 0.00 8,829.61 639.52 -75.03 643.91 0.00 0.00 0.009,000.00 0.00 0.00 8,929.61 639.52 -75.03 643.91 0.00 0.00 0.009,100.00 0.00 0.00 9,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

9,200.00 0.00 0.00 9,129.61 639.52 -75.03 643.91 0.00 0.00 0.009,300.00 0.00 0.00 9,229.61 639.52 -75.03 643.91 0.00 0.00 0.009,395.39 0.00 0.00 9,325.00 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 4 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

5,200.00 0.00 0.00 5,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,300.00 0.00 0.00 5,229.61 639.52 -75.03 643.91 0.00 0.00 0.005,400.00 0.00 0.00 5,329.61 639.52 -75.03 643.91 0.00 0.00 0.005,500.00 0.00 0.00 5,429.61 639.52 -75.03 643.91 0.00 0.00 0.005,600.00 0.00 0.00 5,529.61 639.52 -75.03 643.91 0.00 0.00 0.005,700.00 0.00 0.00 5,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,800.00 0.00 0.00 5,729.61 639.52 -75.03 643.91 0.00 0.00 0.005,900.00 0.00 0.00 5,829.61 639.52 -75.03 643.91 0.00 0.00 0.006,000.00 0.00 0.00 5,929.61 639.52 -75.03 643.91 0.00 0.00 0.006,100.00 0.00 0.00 6,029.61 639.52 -75.03 643.91 0.00 0.00 0.006,200.00 0.00 0.00 6,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,300.00 0.00 0.00 6,229.61 639.52 -75.03 643.91 0.00 0.00 0.006,400.00 0.00 0.00 6,329.61 639.52 -75.03 643.91 0.00 0.00 0.006,500.00 0.00 0.00 6,429.61 639.52 -75.03 643.91 0.00 0.00 0.006,600.00 0.00 0.00 6,529.61 639.52 -75.03 643.91 0.00 0.00 0.006,700.00 0.00 0.00 6,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,800.00 0.00 0.00 6,729.61 639.52 -75.03 643.91 0.00 0.00 0.006,900.00 0.00 0.00 6,829.61 639.52 -75.03 643.91 0.00 0.00 0.007,000.00 0.00 0.00 6,929.61 639.52 -75.03 643.91 0.00 0.00 0.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 643.91 0.00 0.00 0.007,100.00 0.00 0.00 7,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,200.00 0.00 0.00 7,129.61 639.52 -75.03 643.91 0.00 0.00 0.007,300.00 0.00 0.00 7,229.61 639.52 -75.03 643.91 0.00 0.00 0.007,400.00 0.00 0.00 7,329.61 639.52 -75.03 643.91 0.00 0.00 0.007,500.00 0.00 0.00 7,429.61 639.52 -75.03 643.91 0.00 0.00 0.007,600.00 0.00 0.00 7,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,700.00 0.00 0.00 7,629.61 639.52 -75.03 643.91 0.00 0.00 0.007,800.00 0.00 0.00 7,729.61 639.52 -75.03 643.91 0.00 0.00 0.007,900.00 0.00 0.00 7,829.61 639.52 -75.03 643.91 0.00 0.00 0.008,000.00 0.00 0.00 7,929.61 639.52 -75.03 643.91 0.00 0.00 0.008,100.00 0.00 0.00 8,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,200.00 0.00 0.00 8,129.61 639.52 -75.03 643.91 0.00 0.00 0.008,300.00 0.00 0.00 8,229.61 639.52 -75.03 643.91 0.00 0.00 0.008,400.00 0.00 0.00 8,329.61 639.52 -75.03 643.91 0.00 0.00 0.008,500.00 0.00 0.00 8,429.61 639.52 -75.03 643.91 0.00 0.00 0.008,600.00 0.00 0.00 8,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,700.00 0.00 0.00 8,629.61 639.52 -75.03 643.91 0.00 0.00 0.008,800.00 0.00 0.00 8,729.61 639.52 -75.03 643.91 0.00 0.00 0.008,900.00 0.00 0.00 8,829.61 639.52 -75.03 643.91 0.00 0.00 0.009,000.00 0.00 0.00 8,929.61 639.52 -75.03 643.91 0.00 0.00 0.009,100.00 0.00 0.00 9,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

9,200.00 0.00 0.00 9,129.61 639.52 -75.03 643.91 0.00 0.00 0.009,300.00 0.00 0.00 9,229.61 639.52 -75.03 643.91 0.00 0.00 0.009,395.39 0.00 0.00 9,325.00 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 4 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

5,200.00 0.00 0.00 5,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,300.00 0.00 0.00 5,229.61 639.52 -75.03 643.91 0.00 0.00 0.005,400.00 0.00 0.00 5,329.61 639.52 -75.03 643.91 0.00 0.00 0.005,500.00 0.00 0.00 5,429.61 639.52 -75.03 643.91 0.00 0.00 0.005,600.00 0.00 0.00 5,529.61 639.52 -75.03 643.91 0.00 0.00 0.005,700.00 0.00 0.00 5,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,800.00 0.00 0.00 5,729.61 639.52 -75.03 643.91 0.00 0.00 0.005,900.00 0.00 0.00 5,829.61 639.52 -75.03 643.91 0.00 0.00 0.006,000.00 0.00 0.00 5,929.61 639.52 -75.03 643.91 0.00 0.00 0.006,100.00 0.00 0.00 6,029.61 639.52 -75.03 643.91 0.00 0.00 0.006,200.00 0.00 0.00 6,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,300.00 0.00 0.00 6,229.61 639.52 -75.03 643.91 0.00 0.00 0.006,400.00 0.00 0.00 6,329.61 639.52 -75.03 643.91 0.00 0.00 0.006,500.00 0.00 0.00 6,429.61 639.52 -75.03 643.91 0.00 0.00 0.006,600.00 0.00 0.00 6,529.61 639.52 -75.03 643.91 0.00 0.00 0.006,700.00 0.00 0.00 6,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,800.00 0.00 0.00 6,729.61 639.52 -75.03 643.91 0.00 0.00 0.006,900.00 0.00 0.00 6,829.61 639.52 -75.03 643.91 0.00 0.00 0.007,000.00 0.00 0.00 6,929.61 639.52 -75.03 643.91 0.00 0.00 0.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 643.91 0.00 0.00 0.007,100.00 0.00 0.00 7,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,200.00 0.00 0.00 7,129.61 639.52 -75.03 643.91 0.00 0.00 0.007,300.00 0.00 0.00 7,229.61 639.52 -75.03 643.91 0.00 0.00 0.007,400.00 0.00 0.00 7,329.61 639.52 -75.03 643.91 0.00 0.00 0.007,500.00 0.00 0.00 7,429.61 639.52 -75.03 643.91 0.00 0.00 0.007,600.00 0.00 0.00 7,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,700.00 0.00 0.00 7,629.61 639.52 -75.03 643.91 0.00 0.00 0.007,800.00 0.00 0.00 7,729.61 639.52 -75.03 643.91 0.00 0.00 0.007,900.00 0.00 0.00 7,829.61 639.52 -75.03 643.91 0.00 0.00 0.008,000.00 0.00 0.00 7,929.61 639.52 -75.03 643.91 0.00 0.00 0.008,100.00 0.00 0.00 8,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,200.00 0.00 0.00 8,129.61 639.52 -75.03 643.91 0.00 0.00 0.008,300.00 0.00 0.00 8,229.61 639.52 -75.03 643.91 0.00 0.00 0.008,400.00 0.00 0.00 8,329.61 639.52 -75.03 643.91 0.00 0.00 0.008,500.00 0.00 0.00 8,429.61 639.52 -75.03 643.91 0.00 0.00 0.008,600.00 0.00 0.00 8,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,700.00 0.00 0.00 8,629.61 639.52 -75.03 643.91 0.00 0.00 0.008,800.00 0.00 0.00 8,729.61 639.52 -75.03 643.91 0.00 0.00 0.008,900.00 0.00 0.00 8,829.61 639.52 -75.03 643.91 0.00 0.00 0.009,000.00 0.00 0.00 8,929.61 639.52 -75.03 643.91 0.00 0.00 0.009,100.00 0.00 0.00 9,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

9,200.00 0.00 0.00 9,129.61 639.52 -75.03 643.91 0.00 0.00 0.009,300.00 0.00 0.00 9,229.61 639.52 -75.03 643.91 0.00 0.00 0.009,395.39 0.00 0.00 9,325.00 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 4 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Planned Survey

Measured Vertical Vertical Dogleg Build TurnDepth Inclination Azimuth Depth +NI-S +El-W Section Rate Rate Rate

(ft) (deg) (deg) (ft) (ft) (ft) (ft) (?I100ft) (?I100ft) (?I100ft)

5,200.00 0.00 0.00 5,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,300.00 0.00 0.00 5,229.61 639.52 -75.03 643.91 0.00 0.00 0.005,400.00 0.00 0.00 5,329.61 639.52 -75.03 643.91 0.00 0.00 0.005,500.00 0.00 0.00 5,429.61 639.52 -75.03 643.91 0.00 0.00 0.005,600.00 0.00 0.00 5,529.61 639.52 -75.03 643.91 0.00 0.00 0.005,700.00 0.00 0.00 5,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

5,800.00 0.00 0.00 5,729.61 639.52 -75.03 643.91 0.00 0.00 0.005,900.00 0.00 0.00 5,829.61 639.52 -75.03 643.91 0.00 0.00 0.006,000.00 0.00 0.00 5,929.61 639.52 -75.03 643.91 0.00 0.00 0.006,100.00 0.00 0.00 6,029.61 639.52 -75.03 643.91 0.00 0.00 0.006,200.00 0.00 0.00 6,129.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,300.00 0.00 0.00 6,229.61 639.52 -75.03 643.91 0.00 0.00 0.006,400.00 0.00 0.00 6,329.61 639.52 -75.03 643.91 0.00 0.00 0.006,500.00 0.00 0.00 6,429.61 639.52 -75.03 643.91 0.00 0.00 0.006,600.00 0.00 0.00 6,529.61 639.52 -75.03 643.91 0.00 0.00 0.006,700.00 0.00 0.00 6,629.61 639.52 -75.03 643.91 0.00 0.00 0.00

6,800.00 0.00 0.00 6,729.61 639.52 -75.03 643.91 0.00 0.00 0.006,900.00 0.00 0.00 6,829.61 639.52 -75.03 643.91 0.00 0.00 0.007,000.00 0.00 0.00 6,929.61 639.52 -75.03 643.91 0.00 0.00 0.007,027.39 0.00 0.00 6,957.00 639.52 -75.03 643.91 0.00 0.00 0.007,100.00 0.00 0.00 7,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,200.00 0.00 0.00 7,129.61 639.52 -75.03 643.91 0.00 0.00 0.007,300.00 0.00 0.00 7,229.61 639.52 -75.03 643.91 0.00 0.00 0.007,400.00 0.00 0.00 7,329.61 639.52 -75.03 643.91 0.00 0.00 0.007,500.00 0.00 0.00 7,429.61 639.52 -75.03 643.91 0.00 0.00 0.007,600.00 0.00 0.00 7,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

7,700.00 0.00 0.00 7,629.61 639.52 -75.03 643.91 0.00 0.00 0.007,800.00 0.00 0.00 7,729.61 639.52 -75.03 643.91 0.00 0.00 0.007,900.00 0.00 0.00 7,829.61 639.52 -75.03 643.91 0.00 0.00 0.008,000.00 0.00 0.00 7,929.61 639.52 -75.03 643.91 0.00 0.00 0.008,100.00 0.00 0.00 8,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,200.00 0.00 0.00 8,129.61 639.52 -75.03 643.91 0.00 0.00 0.008,300.00 0.00 0.00 8,229.61 639.52 -75.03 643.91 0.00 0.00 0.008,400.00 0.00 0.00 8,329.61 639.52 -75.03 643.91 0.00 0.00 0.008,500.00 0.00 0.00 8,429.61 639.52 -75.03 643.91 0.00 0.00 0.008,600.00 0.00 0.00 8,529.61 639.52 -75.03 643.91 0.00 0.00 0.00

8,700.00 0.00 0.00 8,629.61 639.52 -75.03 643.91 0.00 0.00 0.008,800.00 0.00 0.00 8,729.61 639.52 -75.03 643.91 0.00 0.00 0.008,900.00 0.00 0.00 8,829.61 639.52 -75.03 643.91 0.00 0.00 0.009,000.00 0.00 0.00 8,929.61 639.52 -75.03 643.91 0.00 0.00 0.009,100.00 0.00 0.00 9,029.61 639.52 -75.03 643.91 0.00 0.00 0.00

9,200.00 0.00 0.00 9,129.61 639.52 -75.03 643.91 0.00 0.00 0.009,300.00 0.00 0.00 9,229.61 639.52 -75.03 643.91 0.00 0.00 0.009,395.39 0.00 0.00 9,325.00 639.52 -75.03 643.91 0.00 0.00 0.00

4/26/2010 4:00:48PM Page 4 COMPASS 2003.21 Build

Page 9: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Project:Company:

Local Co-ordinate Reference:TVD Reference:

Site:

Denver Division - UtahT9S-R22E Sec 25CWU 1535-1540 25D (Pad A1_CWU 508-25F_Se

EOG Resources IncPlanning Report

Well:Wellbore:

1535-25DWellbore #1

Survey Calculation Method: Minimum Curvature

RIG @ 5041.00ft (True 34)

Design: APD

Database: EDM

MD Reference: RIG @ 5041.00ft (True 34)North Reference:

Well 1535-25D

True

Target Name - hit/miss target - Shape

TVD(ft)

Northing(ft)

Easting(ft)

+N/-S(ft)

+E/-W(ft)

Targets

LongitudeLatitudeDip Angle

(deg)Dip Dir.

(deg)

CWU 1535-25D 6,957.00 -109,129.75 2,589,790.22639.52 -75.030.00 0.00 40° 0' 51.099 N 109° 23' 40.703 W- plan hits target center- Circle (radius 50.00)

4/26/2010 4:00:48PM COMPASS 2003.21 Build 37 Page 5

'APIWellNo:43047511750000''APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Targets

Target Name- hit/miss target Dip Angle Dip Dir. TVD +NI-S +El-W Northing Easting- Shape (deg) (deg) (ft) (ft) (ft) (ft) (ft) Latitude Longitude

CWU 1535-25D 0.00 0.00 6,957.00 639.52 -75.03-109,129.75 2,589,790.22 40° O' 51.099 N 109° 23' 40.703 W

- plan hits target center- Circle (radius 50.00)

4/26/2010 4 00 48PM Page 5 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Targets

Target Name- hit/miss target Dip Angle Dip Dir. TVD +NI-S +El-W Northing Easting- Shape (deg) (deg) (ft) (ft) (ft) (ft) (ft) Latitude Longitude

CWU 1535-25D 0.00 0.00 6,957.00 639.52 -75.03-109,129.75 2,589,790.22 40° O' 51.099 N 109° 23' 40.703 W

- plan hits target center- Circle (radius 50.00)

4/26/2010 4 00 48PM Page 5 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Targets

Target Name- hit/miss target Dip Angle Dip Dir. TVD +NI-S +El-W Northing Easting- Shape (deg) (deg) (ft) (ft) (ft) (ft) (ft) Latitude Longitude

CWU 1535-25D 0.00 0.00 6,957.00 639.52 -75.03-109,129.75 2,589,790.22 40° O' 51.099 N 109° 23' 40.703 W

- plan hits target center- Circle (radius 50.00)

4/26/2010 4 00 48PM Page 5 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Targets

Target Name- hit/miss target Dip Angle Dip Dir. TVD +NI-S +El-W Northing Easting- Shape (deg) (deg) (ft) (ft) (ft) (ft) (ft) Latitude Longitude

CWU 1535-25D 0.00 0.00 6,957.00 639.52 -75.03-109,129.75 2,589,790.22 40° O' 51.099 N 109° 23' 40.703 W

- plan hits target center- Circle (radius 50.00)

4/26/2010 4 00 48PM Page 5 COMPASS 2003.21 Build

'APIWellNo:43047511750000'EOG Resources Inc

Planning Report

Database: EDM Local Co-ordinate Reference: Well 1535-25DCompany: Denver Division - Utah TVD Reference: RIG @5041.00ft (True 34)Project: T9S-R22E Sec 25 MD Reference: RIG @5041.00ft (True 34)Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Si North Reference: TrueWell: 1535-25D Survey Calculation Method: Minimum CurvatureWellbore: Wellbore #1Design: APD

Targets

Target Name- hit/miss target Dip Angle Dip Dir. TVD +NI-S +El-W Northing Easting- Shape (deg) (deg) (ft) (ft) (ft) (ft) (ft) Latitude Longitude

CWU 1535-25D 0.00 0.00 6,957.00 639.52 -75.03-109,129.75 2,589,790.22 40° O' 51.099 N 109° 23' 40.703 W

- plan hits target center- Circle (radius 50.00)

4/26/2010 4 00 48PM Page 5 COMPASS 2003.21 Build

Page 10: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Azimuths to True NorthMagnetic North: 11.24°

Magnetic FieldStrength: 52552.8snT

Dip Angle: 65.95°Date: 9/17/2009

Model: IGRF200510

T M

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +E/-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +E/-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° 0' 51.099 N 109° 23' 40.703 W Circle (Radius: 50.00)

Surface Location

NAD 1927 (NADCON CONUS) Utah North 4301Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude0.00 -109767.26 2589880.72 40° 0' 44.780 N 109° 23' 39.739 W

0

250

500

750

Sout

h(-)/

Nor

th(+

) (25

0 ft/

in)

-500 -250 0 250

West(-)/East(+) (250 ft/in)

CWU 1535-25D

-750

0

750

1500

2250

3000

3750

4500

5250

6000

6750

7500

8250

9000

9750

True

Ver

tical

Dep

th (1

500

ft/in

)

-750 0 750 1500

Vertical Section at 353.31deg (1500 ft/in)

Start Build 1.50

Start 1230.67 hold at 1300.00 MD

Start Drop -1.00

Start 2996.72 hold at 4030.68 MD

Start 2368.00 hold at 7027.39 MD

TD at 9395.39

Project: T9S-R22E Sec 25Site: CWU 1535-1540 25D (Pad A1_CWU 508-25F_Set 12)Well: 1535-25DPlan: APD

CWU 1535-25DSection 25 T9S R22EUintah County, UT

'APIWellNo:43047511750000''APIWellNo:43047511750000'-750 _ UGOg feSOUTCOS

O----- ---- StartBuild1.50 CWU 1535-25D

Section 25 T9S R22E750 _ Uintah County, UT

- - - - - - - - Start 1230.67 hold at 1300.00 M1500

Surface Location

2250 NAD 1927 (NADCON CONUS) Utah North 4301- - - - - - - - - - Start Drop -1.00 Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude)0 -109767.26 2589880.72 40° O' 44.780 N 109° 23' 39.739 W

3000

50 I

3750- - - - Start 2996.72 hold at 4030.68 M

CWU 1535-2 D

t 5250o o

O

- - - - Start 2368.00 hold at 7027.39 MI

8250

-530 -250 0 200

5000 West(-)/East(+) (250 ft/in)- - - - TD at 9395.39

9750 M Azimuths to True North/\ Magnetic North: 11.24°

Project: T9S-R22E Sec 25 Magnetic Field| I I I Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Set 12)

-750 0 760 1500 Well: 1535-25D Strength: 52552.8snT

Plan: APD Dip Angle: 65.95°

Date: 9/17/2009Vertical Section at 353.31deg (1500 ft/in) Model: IGRF200510

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +El-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +El-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° O' 51.099 N 109° 23' 40.703 W Circle (Radius:

'APIWellNo:43047511750000'-750 _ UGOg feSOUTCOS

O

----- ---- StartBuild1.50 CWU 1535-25DSection 25 T9S R22E

750 _ Uintah County, UT

- - - - - - - - Start 1230.67 hold at 1300.00 M1500

Surface Location

2250 NAD 1927 (NADCON CONUS) Utah North 4301- - - - - - - - - - Start Drop -1.00 Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude)0 -109767.26 2589880.72 40° O' 44.780 N 109° 23' 39.739 W

3000

50 I

3750- - - - Start 2996.72 hold at 4030.68 M

CWU 1535-2 D

t 5250o o

O

- - - - Start 2368.00 hold at 7027.39 MI

8250

-530 -250 0 200

5000 West(-)/East(+) (250 ft/in)- - - - TD at 9395.39

9750 M Azimuths to True North/\ Magnetic North: 11.24°

Project: T9S-R22E Sec 25 Magnetic Field| I I I Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Set 12)

-750 0 760 1500 Well: 1535-25D Strength: 52552.8snT

Plan: APD Dip Angle: 65.95°

Date: 9/17/2009Vertical Section at 353.31deg (1500 ft/in) Model: IGRF200510

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +El-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +El-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° O' 51.099 N 109° 23' 40.703 W Circle (Radius:

'APIWellNo:43047511750000'-750 _ UGOg feSOUTCOS

O

----- ---- StartBuild1.50 CWU 1535-25DSection 25 T9S R22E

750 _ Uintah County, UT

- - - - - - - - Start 1230.67 hold at 1300.00 M1500

Surface Location

2250 NAD 1927 (NADCON CONUS) Utah North 4301- - - - - - - - - - Start Drop -1.00 Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude)0 -109767.26 2589880.72 40° O' 44.780 N 109° 23' 39.739 W

3000

50 I

3750- - - - Start 2996.72 hold at 4030.68 M

CWU 1535-2 D

t 5250o o

O

- - - - Start 2368.00 hold at 7027.39 MI

8250

-530 -250 0 200

5000 West(-)/East(+) (250 ft/in)- - - - TD at 9395.39

9750 M Azimuths to True North/\ Magnetic North: 11.24°

Project: T9S-R22E Sec 25 Magnetic Field| I I I Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Set 12)

-750 0 760 1500 Well: 1535-25D Strength: 52552.8snT

Plan: APD Dip Angle: 65.95°

Date: 9/17/2009Vertical Section at 353.31deg (1500 ft/in) Model: IGRF200510

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +El-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +El-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° O' 51.099 N 109° 23' 40.703 W Circle (Radius:

'APIWellNo:43047511750000'-750 _ UGOg feSOUTCOS

O

----- ---- StartBuild1.50 CWU 1535-25DSection 25 T9S R22E

750 _ Uintah County, UT

- - - - - - - - Start 1230.67 hold at 1300.00 M1500

Surface Location

2250 NAD 1927 (NADCON CONUS) Utah North 4301- - - - - - - - - - Start Drop -1.00 Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude)0 -109767.26 2589880.72 40° O' 44.780 N 109° 23' 39.739 W

3000

50 I

3750- - - - Start 2996.72 hold at 4030.68 M

CWU 1535-2 D

t 5250o o

O

- - - - Start 2368.00 hold at 7027.39 MI

8250

-530 -250 0 200

5000 West(-)/East(+) (250 ft/in)- - - - TD at 9395.39

9750 M Azimuths to True North/\ Magnetic North: 11.24°

Project: T9S-R22E Sec 25 Magnetic Field| I I I Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Set 12)

-750 0 760 1500 Well: 1535-25D Strength: 52552.8snT

Plan: APD Dip Angle: 65.95°

Date: 9/17/2009Vertical Section at 353.31deg (1500 ft/in) Model: IGRF200510

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +El-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +El-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° O' 51.099 N 109° 23' 40.703 W Circle (Radius:

'APIWellNo:43047511750000'-750 _ UGOg feSOUTCOS

O

----- ---- StartBuild1.50 CWU 1535-25DSection 25 T9S R22E

750 _ Uintah County, UT

- - - - - - - - Start 1230.67 hold at 1300.00 M1500

Surface Location

2250 NAD 1927 (NADCON CONUS) Utah North 4301- - - - - - - - - - Start Drop -1.00 Ground Elevation: 5022.00 RIG @ 5041.00ft (True 34)

Northing Easting Latittude Longitude)0 -109767.26 2589880.72 40° O' 44.780 N 109° 23' 39.739 W

3000

50 I

3750- - - - Start 2996.72 hold at 4030.68 M

CWU 1535-2 D

t 5250o o

O

- - - - Start 2368.00 hold at 7027.39 MI

8250

-530 -250 0 200

5000 West(-)/East(+) (250 ft/in)- - - - TD at 9395.39

9750 M Azimuths to True North/\ Magnetic North: 11.24°

Project: T9S-R22E Sec 25 Magnetic Field| I I I Site: CWU 1535-1540 25D (Pad A1 CWU 508-25F Set 12)

-750 0 760 1500 Well: 1535-25D Strength: 52552.8snT

Plan: APD Dip Angle: 65.95°

Date: 9/17/2009Vertical Section at 353.31deg (1500 ft/in) Model: IGRF200510

SECTION DETAILS

Sec MD Inc Azi TVD +N/-S +El-W DLeg TFace VSec Target1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.002 300.00 0.00 0.00 300.00 0.00 0.00 0.00 0.00 0.003 1300.00 15.00 353.31 1288.62 129.27 -15.17 1.50 353.31 130.154 2530.67 15.00 353.31 2477.35 445.62 -52.28 0.00 0.00 448.675 4030.68 0.00 0.00 3960.28 639.52 -75.03 1.00 180.00 643.916 7027.39 0.00 0.00 6957.00 639.52 -75.03 0.00 0.00 643.91 CWU 1535-25D7 9395.39 0.00 0.00 9325.00 639.52 -75.03 0.00 0.00 643.91

TARGET DETAILS

Name TVD +N/-S +El-W Northing Easting Latitude Longitude ShapeCWU 1535-25D 6957.00 639.52 -75.03 -109129.75 2589790.22 40° O' 51.099 N 109° 23' 40.703 W Circle (Radius:

Page 11: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

-600

-525

-450

-375

-300

-225

-150

-75

0

75

150

225

300

375

450

525

600

Sou

th(-

)/N

orth

(+)

(150

ft/in

)

-525 -450 -375 -300 -225 -150 -75 0 75 150 225 300 375 450

West(-)/East(+) (150 ft/in)

0784-25/Vertical well

1538-25D/APD

1537-25D/APD

1536-25D/APD

1535-25D/APD

1540-25D/APD

1539-25D/APD 0508-25F/Gyro Survey

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

1535-25DIAPD000

450

375 1536 -25DIAPD

aoo1540-25DIAPD

0784-25/Vertical well

1537-25DIAPD

-3001539-25DIAPD 0508-26F/Gyro -3urvey

-450

1538-25DIAPD

-000

-525 -450 -375 -300 -225 -150 -75 f) 75 1 ¡O 225 3t)O 3'5 4tiOWest(-)/East(-l) (150

'APIWellNo:43047511750000'

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

1535-25DIAPD000

450

375 1536 -25DIAPD

aoo1540-25DIAPD

0784-25/Vertical well

1537-25DIAPD

-3001539-25DIAPD 0508-26F/Gyro -3urvey

-450

1538-25DIAPD

-000

-525 -450 -375 -300 -225 -150 -75 f) 75 1 ¡O 225 3t)O 3'5 4tiO

West(-)/East(-l) (150

'APIWellNo:43047511750000'

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

1535-25DIAPD000

450

375 1536 -25DIAPD

aoo1540-25DIAPD

0784-25/Vertical well

1537-25DIAPD

-3001539-25DIAPD 0508-26F/Gyro -3urvey

-450

1538-25DIAPD

-000

-525 -450 -375 -300 -225 -150 -75 f) 75 1 ¡O 225 3t)O 3'5 4tiO

West(-)/East(-l) (150

'APIWellNo:43047511750000'

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

1535-25DIAPD000

450

375 1536 -25DIAPD

aoo1540-25DIAPD

0784-25/Vertical well

1537-25DIAPD

-3001539-25DIAPD 0508-26F/Gyro -3urvey

-450

1538-25DIAPD

-000

-525 -450 -375 -300 -225 -150 -75 f) 75 1 ¡O 225 3t)O 3'5 4tiO

West(-)/East(-l) (150

'APIWellNo:43047511750000'

CWU 1535-25D, CWU 1536-25D, CWU 1537-25DCWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25 T9S, R22E, S.L.B. & M.UINTAH COUNTY, UTAH

1535-25DIAPD000

450

375 1536 -25DIAPD

aoo1540-25DIAPD

0784-25/Vertical well

1537-25DIAPD

-3001539-25DIAPD 0508-26F/Gyro -3urvey

-450

1538-25DIAPD

-000

-525 -450 -375 -300 -225 -150 -75 f) 75 1 ¡O 225 3t)O 3'5 4tiO

West(-)/East(-l) (150

Page 12: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

DRILLING PLAN MULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D, CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25, T9S, R22E, S.L.B.&M.. UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MD Green River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758 Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653 Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246 Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917 North Horn 6599 6669 6592 6632 6544 6598 6537 6599

KMV Price River 6957 7028 6949 6989 6892 6945 6884 6945 KMV Price River Middle 7825 7895 7817 7857 7765 7818 7756 7818 KMV Price River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138 TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D FORMATION TVD MD TVD MD Green River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757 Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678 Chapita Wells 5206 5240 5230 5269 Buck Canyon 5866 5900 5895 5933 North Horn 6570 6605 6594 6632

KMV Price River 6919 6954 6952 6990 KMV Price River Middle 7791 7825 7821 7860 KMV Price River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160 TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,

with top at about 2,000 ft ±. 2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5 7/26/2010

'APIWellNo:43047511750000''APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MDGreen River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917

Nodh Horn 6599 6669 6592 6632 6544 6598 6537 6599KMVPrice River 6957 7028 6949 6989 6892 6945 6884 6945

KMVPrice River Middle 7825 7895 7817 7857 7765 7818 7756 7818KMVPrice River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D

FORMATION TVD MD TVD MDGreen River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678Chapita Wells 5206 5240 5230 5269Buck Canyon 5866 5900 5895 5933

Nodh Horn 6570 6605 6594 6632KMVPrice River 6919 6954 6952 6990

KMVPrice River Middle 7791 7825 7821 7860KMVPrice River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,with top at about 2,000 ft ±.

2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MDGreen River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917

Nodh Horn 6599 6669 6592 6632 6544 6598 6537 6599KMVPrice River 6957 7028 6949 6989 6892 6945 6884 6945

KMVPrice River Middle 7825 7895 7817 7857 7765 7818 7756 7818KMVPrice River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D

FORMATION TVD MD TVD MDGreen River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678Chapita Wells 5206 5240 5230 5269Buck Canyon 5866 5900 5895 5933

Nodh Horn 6570 6605 6594 6632KMVPrice River 6919 6954 6952 6990

KMVPrice River Middle 7791 7825 7821 7860KMVPrice River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,with top at about 2,000 ft ±.

2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MDGreen River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917

Nodh Horn 6599 6669 6592 6632 6544 6598 6537 6599KMVPrice River 6957 7028 6949 6989 6892 6945 6884 6945

KMVPrice River Middle 7825 7895 7817 7857 7765 7818 7756 7818KMVPrice River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D

FORMATION TVD MD TVD MDGreen River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678Chapita Wells 5206 5240 5230 5269Buck Canyon 5866 5900 5895 5933

Nodh Horn 6570 6605 6594 6632KMVPrice River 6919 6954 6952 6990

KMVPrice River Middle 7791 7825 7821 7860KMVPrice River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,with top at about 2,000 ft ±.

2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MDGreen River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917

Nodh Horn 6599 6669 6592 6632 6544 6598 6537 6599KMVPrice River 6957 7028 6949 6989 6892 6945 6884 6945

KMVPrice River Middle 7825 7895 7817 7857 7765 7818 7756 7818KMVPrice River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D

FORMATION TVD MD TVD MDGreen River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678Chapita Wells 5206 5240 5230 5269Buck Canyon 5866 5900 5895 5933

Nodh Horn 6570 6605 6594 6632KMVPrice River 6919 6954 6952 6990

KMVPrice River Middle 7791 7825 7821 7860KMVPrice River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,with top at about 2,000 ft ±.

2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

1. & 2. ESTIMATED TOPS & ANTICIPATED OIL, GAS, & WATER ZONES:

CWU 1535-25D CWU 1536-25D CWU 1537-25D CWU 1538-25D

FORMATION TVD MD TVD MD TVD MD TVD MDGreen River 1522 1541 1517 1531 1537 1554 1554 1570

Birdsnest 1738 1765 1731 1748 1727 1749 1736 1758Mahogany Oil Shale Bed 2294 2341 2289 2317 2262 2297 2259 2297

Wasatch 4647 4717 4643 4682 4603 4656 4592 4653Chapita Wells 5238 5308 5234 5273 5194 5248 5184 5246Buck Canyon 5907 5977 5905 5944 5872 5925 5855 5917

Nodh Horn 6599 6669 6592 6632 6544 6598 6537 6599KMVPrice River 6957 7028 6949 6989 6892 6945 6884 6945

KMVPrice River Middle 7825 7895 7817 7857 7765 7818 7756 7818KMVPrice River Lower 8620 8691 8614 8653 8564 8617 8552 8613

Sego 9124 9195 9119 9158 9083 9137 9077 9138TD 9325 9396 9320 9359 9285 9339 9280 9341

ANTICIPATED BHP (PSI) 5092 5089 5070 5067

CWU 1539-25D CWU 1540-25D

FORMATION TVD MD TVD MDGreen River 1559 1571 1534 1548

Birdsnest 1739 1754 1740 1757Mahogany Oil Shale Bed 2270 2294 2287 2315

Wasatch 4614 4648 4640 4678Chapita Wells 5206 5240 5230 5269Buck Canyon 5866 5900 5895 5933

Nodh Horn 6570 6605 6594 6632KMVPrice River 6919 6954 6952 6990

KMVPrice River Middle 7791 7825 7821 7860KMVPrice River Lower 8584 8618 8614 8652

Sego 9109 9144 9122 9160TD 9310 9345 9325 9363

ANTICIPATED BHP (PSI) 5083 5091

1. Fresh Waters may exist in the upper, approximately 1,000 ft ± of the Green River Formation,with top at about 2,000 ft ±.

2. Cement isolation is installed to surface of the well isolating all zones by cement.

8 point plan-EOG 1/5

Page 13: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

DRILLING PLAN MULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D, CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25, T9S, R22E, S.L.B.&M.. UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole – 5000 Psig BOP schematic diagrams attached. 4. CASING PROGRAM:

Casing Hole Size Length Size Weight Grade Thread

Rating Collapse

Rating Burst

Tensile

Conductor 20” 0 – 60’ 14” 32.5# A252 1800 PSI 10,000#

Surface 12 ¼” 0 – 2,300’± 9 ⅝” 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8” Surface – TD 4 ½” 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼” surface hole will be drilled to a total depth of 200’± below the base of the Green River lost circulation zone and cased w/9-⅝” as shown to that depth. Drilled depth may be shallower or deeper than the 2300’ shown above depending on the actual depth of the loss zone.

All casing will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0’- 2300’±) Guide Shoe Insert Float Collar (PDC drillable) Centralizers: 1-5’ above shoe, top of jts. #2 and #3 then every 5th joint to surface. (15 total)

Production Hole Procedure (2300’± - TD): Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½”, 11.6#, N-80 or equivalent marker collars or short casing joints to be placed at top of Price River and 400’ above top of Wasatch. Centralizers to be placed 5’ above shoe on joint #1, top of joint #2, and every 3rd joint to 400’ above the top of primary objective. Thread lock float shoe, top and bottom of float collar, and top of 2nd joint.

6. MUD PROGRAM Surface Hole Procedure (Surface - 2300’±):

0’ - 2300’± Air/Air mist/Aerated water or

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions, etc. will be utilized as necessary.

8 point plan-EOG 2/5 7/26/2010

'APIWellNo:43047511750000''APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole - 5000 PsigBOP schematic diagrams attached.

4. CASING PROGRAM:

Hole Rating RatingCasing Size Length Size Weight Grade Thread Collapse Burst Tensile

Conductor 20" O - 60' 14" 32.5# A252 1800 PSI 10,000#

Surface 12 ¼" 0 - 2,300'± 9 %" 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8" Surface - TD 4 ½" 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼" surface hole will be drilled to a total depth of 200'± below the base of the Green River lostcirculation zone and cased wl9-%" as shown to that depth. Drilled depth may be shallower ordeeper than the 2300' shown above depending on the actual depth of the loss zone.

AII casing will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0'-2300'±)

Guide ShoeInsert Float Collar (PDC drillable)Centralizers: 1-5' above shoe, top of jts. #2 and #3 then every 5th

jOint to surface. (15 total)

Production Hole Procedure (2300'± - TD):

Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½", 11.6#, N-80 or equivalent markercollars or short casing joints to be placed at top of Price River and 400' above top of Wasatch. Centralizers to beplaced 5' above shoe on joint #1, top of joint #2, and every 3rd joint to 400' above the top of primary objective.Thread lock float shoe, top and bottom of float collar, and top of 2nd

jOint.

6. MUD PROGRAM

Surface Hole Procedure (Surface - 2300'±):

0' - 2300'± Air/Airmist/Aerated wateror

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions,etc. will be utilized as necessary.

8 point plan-EOG 2/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole-5000 PsigBOP schematic diagrams attached.

4. CASING PROGRAM:

Hole Rating RatingCasing Size Length Size Weight Grade Thread Collapse Burst Tensile

Conductor 20" O - 60' 14" 32.5# A252 1800 PSI 10,000#

Surface 12 ¼" O - 2,300'± 9 %" 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8" Surface - TD 4 ½" 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼" surface hole will be drilled to a total depth of 200'± below the base of the Green River lostcirculation zone and cased wl9-¾" as shown to that depth. Drilled depth may be shallower ordeeper than the 2300' shown above depending on the actual depth of the loss zone.

AII casinq will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0'- 2300'±)

Guide ShoeInsert Float Collar (PDC drillable)Centralizers: 1-5' above shoe, top of jts. #2 and #3 then every 5th

jOint to surface. (15 total)

Production Hole Procedure (2300'± - TD):

Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½", 11.6#, N-80 or equivalent markercollars or short casing joints to be placed at top of Price River and 400' above top of Wasatch. Centralizers to beplaced 5' above shoe on joint #1, top of joint #2, and every 3rd joint to 400' above the top of primary objective.Thread lock float shoe, top and bottom of float collar, and top of 2nd

jOint.

6. MUD PROGRAM

Surface Hole Procedure (Surface - 2300'±):

0' - 2300'± Air/Airmist/Aerated wateror

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions,etc. will be utilized as necessary.

8 point plan-EOG 2/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole-5000 PsigBOP schematic diagrams attached.

4. CASING PROGRAM:

Hole Rating RatingCasing Size Length Size Weight Grade Thread Collapse Burst Tensile

Conductor 20" O - 60' 14" 32.5# A252 1800 PSI 10,000#

Surface 12 ¼" O - 2,300'± 9 %" 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8" Surface - TD 4 ½" 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼" surface hole will be drilled to a total depth of 200'± below the base of the Green River lostcirculation zone and cased wl9-¾" as shown to that depth. Drilled depth may be shallower ordeeper than the 2300' shown above depending on the actual depth of the loss zone.

AII casinq will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0'- 2300'±)

Guide ShoeInsert Float Collar (PDC drillable)Centralizers: 1-5' above shoe, top of jts. #2 and #3 then every 5th

jOint to surface. (15 total)

Production Hole Procedure (2300'± - TD):

Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½", 11.6#, N-80 or equivalent markercollars or short casing joints to be placed at top of Price River and 400' above top of Wasatch. Centralizers to beplaced 5' above shoe on joint #1, top of joint #2, and every 3rd joint to 400' above the top of primary objective.Thread lock float shoe, top and bottom of float collar, and top of 2nd

jOint.

6. MUD PROGRAM

Surface Hole Procedure (Surface - 2300'±):

0' - 2300'± Air/Airmist/Aerated wateror

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions,etc. will be utilized as necessary.

8 point plan-EOG 2/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole-5000 PsigBOP schematic diagrams attached.

4. CASING PROGRAM:

Hole Rating RatingCasing Size Length Size Weight Grade Thread Collapse Burst Tensile

Conductor 20" O - 60' 14" 32.5# A252 1800 PSI 10,000#

Surface 12 ¼" O - 2,300'± 9 %" 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8" Surface - TD 4 ½" 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼" surface hole will be drilled to a total depth of 200'± below the base of the Green River lostcirculation zone and cased wl9-¾" as shown to that depth. Drilled depth may be shallower ordeeper than the 2300' shown above depending on the actual depth of the loss zone.

AII casinq will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0'- 2300'±)

Guide ShoeInsert Float Collar (PDC drillable)Centralizers: 1-5' above shoe, top of jts. #2 and #3 then every 5th

jOint to surface. (15 total)

Production Hole Procedure (2300'± - TD):

Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½", 11.6#, N-80 or equivalent markercollars or short casing joints to be placed at top of Price River and 400' above top of Wasatch. Centralizers to beplaced 5' above shoe on joint #1, top of joint #2, and every 3rd joint to 400' above the top of primary objective.Thread lock float shoe, top and bottom of float collar, and top of 2nd

jOint.

6. MUD PROGRAM

Surface Hole Procedure (Surface - 2300'±):

0' - 2300'± Air/Airmist/Aerated wateror

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions,etc. will be utilized as necessary.

8 point plan-EOG 2/5

'APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

3. PRESSURE CONTROL EQUIPMENT: Production Hole-5000 PsigBOP schematic diagrams attached.

4. CASING PROGRAM:

Hole Rating RatingCasing Size Length Size Weight Grade Thread Collapse Burst Tensile

Conductor 20" O - 60' 14" 32.5# A252 1800 PSI 10,000#

Surface 12 ¼" O - 2,300'± 9 %" 36.0# J-55 STC 2020 PSI 3520 PSI 394,000#

Production 7 7/8" Surface - TD 4 ½" 11.6# N-80 LTC 6350 PSI 7780 PSI 223,000#

Note: 12 ¼" surface hole will be drilled to a total depth of 200'± below the base of the Green River lostcirculation zone and cased wl9-¾" as shown to that depth. Drilled depth may be shallower ordeeper than the 2300' shown above depending on the actual depth of the loss zone.

AII casinq will be new or inspected.

5. Float Equipment:

Surface Hole Procedure (0'- 2300'±)

Guide ShoeInsert Float Collar (PDC drillable)Centralizers: 1-5' above shoe, top of jts. #2 and #3 then every 5th

jOint to surface. (15 total)

Production Hole Procedure (2300'± - TD):

Float shoe, 1 joint casing, float collar and balance of casing to surface. 4-½", 11.6#, N-80 or equivalent markercollars or short casing joints to be placed at top of Price River and 400' above top of Wasatch. Centralizers to beplaced 5' above shoe on joint #1, top of joint #2, and every 3rd joint to 400' above the top of primary objective.Thread lock float shoe, top and bottom of float collar, and top of 2nd

jOint.

6. MUD PROGRAM

Surface Hole Procedure (Surface - 2300'±):

0' - 2300'± Air/Airmist/Aerated wateror

A closed mud system will be utilized with a gelled bentonite system. LCM sweeps, additions,etc. will be utilized as necessary.

8 point plan-EOG 2/5

Page 14: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

DRILLING PLAN MULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D, CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25, T9S, R22E, S.L.B.&M.. UINTAH COUNTY, UTAH

Production Hole Procedure (2300’± - TD): Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered while

drilling. 2300’± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to control

viscosity w/PHPA polymer used for supplemental viscosity and clay encapsulation/inhibition. Water loss will be maintained at <15cc’s using white starch or PAC. Bactericides will be used as needed. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary for well control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCM sweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination, if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1 Onshore Oil and Gas Order No. 2 – Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100’ in

length. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100’ in length. To reduce location excavation, the blooie line will be approximately 75’ in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring

dedusting equipment. Dust during air drilling operations is controlled by water mist. o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring an

automatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system). o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from the

blooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: None Cased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5 7/26/2010

'APIWellNo:43047511750000''APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

Production Hole Procedure (2300'± - TD):

Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered whiledrilling.

2300'± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to controlviscosity w/PHPA polymer used for supplemental viscosity and clay encapsulationlinhibition.Water loss will be maintained at <15cc's using white starch or PAC. Bactericides will be used asneeded. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary forwell control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCMsweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination,if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1Onshore Oil and Gas Order No. 2 - Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100' inlength. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100' in length. Toreduce location excavation, the blooie line will be approximately 75' in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiringdedusting equipment. Dust during air drilling operations is controlled by water mist.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring anautomatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system).

o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from theblooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: NoneCased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

Production Hole Procedure (2300'± - TD):

Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered whiledrilling.

2300'± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to controlviscosity w/PHPA polymer used for supplemental viscosity and clay encapsulationlinhibition.Water loss will be maintained at <15cc's using white starch or PAC. Bactericides will be used asneeded. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary forwell control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCMsweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination,if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1Onshore Oil and Gas Order No. 2 - Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100' inlength. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100' in length. Toreduce location excavation, the blooie line will be approximately 75' in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiringdedusting equipment. Dust during air drilling operations is controlled by water mist.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring anautomatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system).

o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from theblooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: NoneCased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

Production Hole Procedure (2300'± - TD):

Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered whiledrilling.

2300'± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to controlviscosity w/PHPA polymer used for supplemental viscosity and clay encapsulationlinhibition.Water loss will be maintained at <15cc's using white starch or PAC. Bactericides will be used asneeded. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary forwell control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCMsweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination,if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1Onshore Oil and Gas Order No. 2 - Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100' inlength. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100' in length. Toreduce location excavation, the blooie line will be approximately 75' in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiringdedusting equipment. Dust during air drilling operations is controlled by water mist.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring anautomatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system).

o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from theblooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: NoneCased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

Production Hole Procedure (2300'± - TD):

Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered whiledrilling.

2300'± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to controlviscosity w/PHPA polymer used for supplemental viscosity and clay encapsulationlinhibition.Water loss will be maintained at <15cc's using white starch or PAC. Bactericides will be used asneeded. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary forwell control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCMsweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination,if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1Onshore Oil and Gas Order No. 2 - Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100' inlength. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100' in length. Toreduce location excavation, the blooie line will be approximately 75' in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiringdedusting equipment. Dust during air drilling operations is controlled by water mist.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring anautomatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system).

o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from theblooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: NoneCased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

Production Hole Procedure (2300'± - TD):

Anticipated mud weight 9.5-10.5 ppg depending on actul wellbore conditions encountered whiledrilling.

2300'± - TD A closed mud system will be utilized. A bentonite gelled water mud system will be used to controlviscosity w/PHPA polymer used for supplemental viscosity and clay encapsulationlinhibition.Water loss will be maintained at <15cc's using white starch or PAC. Bactericides will be used asneeded. Anticipated pH will range from 9.0-10.0. Mud weight will be adjusted as necessary forwell control. Deflocculants/thinners will be used as necessary to maintain mud quality. LCMsweeps will be utilized as necessary to control lost circulation and mud loss. CO2 contamination,if encountered, will be treated with lime and gypsum.

7. VARIANCE REQUESTS:

Reference: Onshore Oil and Gas Order No. 1Onshore Oil and Gas Order No. 2 - Section E: Special Drilling Operations

o EOG Resources, Inc. requests a variance to regulations requiring a straight run blooie line to be 100' inlength. (Where possible, a straight run blooie line will be used).

o EOG Resources, Inc. requests a variance to regulations requiring the blooie line to be 100' in length. Toreduce location excavation, the blooie line will be approximately 75' in length.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiringdedusting equipment. Dust during air drilling operations is controlled by water mist.

o EOG Resources, Inc. requests a variance to regulations, during air drilling operations only, requiring anautomatic igniter or continuous pilot light on the blooie line. (Not required on aerated water system).

o EOG Resources, Inc. requests a variance that compressors are located in the opposite direction from theblooie line a minimum of 100 feet from the well bore. (Air Compressors are rig mounted).

8. EVALUATION PROGRAM:

Logs: NoneCased-hole Logs: Cased-hole logs will be run in lieu of open-hole logs consisting of the following:

Cement Bond / Casing Collar Locator and Gamma Ray

8 point plan-EOG 3/5

Page 15: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

DRILLING PLAN MULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D, CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25, T9S, R22E, S.L.B.&M.. UINTAH COUNTY, UTAH

9. CEMENT PROGRAM: Surface Hole Procedure (Surface - 2300’±):

Lead: 150 sks Class “G” cement with 16% Gel, 10 #/sx Gilsonite, 3% Salt, 2% CaCI2, 3 lb/sx GR3 ¼ #/sx Flocele mixed at 11 ppg, 3.82 ft3/sk. yield, 23 gps water.

Tail: 135 sks Class "G” cement with 2% CaCI2, ¼#/sk Flocele mixed at 15.6 ppg, 1.18 ft3/sk.,

5.2 gps water.

Top Out: As necessary with Class “G” cement with 2% CaCI2, ¼#/sk Flocele mixed at 15.6 ppg, 1.18 ft3/sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculation

Lead volume to be calculated to bring cement to surface. Tail volume to be calculated to bring cement to 500’ above the shoe.

Production Hole Procedure (2300’± - TD) Lead: 128 sks: Hi-Lift “G” w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44

(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29 (cello flakes) mixed at 11.0 ppg, 3.91 ft3/sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz “G” w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%

D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant), mixed at 14.1 ppg, 1.28 ft3/sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.

Lead volume to be calculated to bring cement to 200’± above 9-5/8” casing shoe. Tail volume to be calculated to bring cement to 400’± above top of Wasatch. Final Cement volumes will be based upon gauge-hole plus 45% excess.

8 point plan-EOG 4/5 7/26/2010

'APIWellNo:43047511750000''APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

9. CEMENT PROGRAM:

Surface Hole Procedure (Surface - 2300'±):

Lead: 150 sks Class "G" cement with 16% Gel, 10 #/sx Gilsonite, 3% Salt, 2% CaCl2,3 lb/sx GR3 ¼ #/sx Flocele mixed at 11 ppg, 3.82 ñ3/Sk. yield, 23 gps water.

Tail: 135 sks Class "G" cement with 2% CaCl2, ¼#/Sk Flocele mixed at 15.6 ppg, 1.18 ñ3/Sk.,

5.2 gps water.

Top Out: As necessary with Class "G" cement with 2% CaCl2, ¼#/Sk Flocele mixed at 15.6ppg, 1.18 ñ3/Sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculationLead volume to be calculated to bring cement to surface.Tail volume to be calculated to bring cement to 500' above the shoe.

Production Hole Procedure (2300'± - TD)

Lead: 128 sks: Hi-Lift"G"w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29(cello flakes) mixed at 11.0 ppg, 3.91 ñ3/Sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz "G" w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant),mixed at 14.1 ppg, 1.28 ñ3/Sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.Lead volume to be calculated to bring cement to 200'± above 9-5/8" casing shoe.Tail volume to be calculated to bring cement to 400'± above top of Wasatch.

Final Cement volumes will be based upon qauqe-hole plus 45% excess.

8 point plan-EOG 4/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

9. CEMENT PROGRAM:

Surface Hole Procedure (Surface - 2300'±):

Lead: 150 sks Class "G" cement with 16% Gel, 10 #lsx Gilsonite, 3% Salt, 2% CaCl2,3 lb/sx GR3 ¼ #lsx Flocele mixed at 11 ppg, 3.82 ñ3/Sk. yield, 23 gps water.

Tail: 135 sks Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6 ppg, 1.18 ñ3/Sk.,

5.2 gps water.

Top Out: As necessary with Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6ppg, 1.18 ñ3/Sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculationLead volume to be calculated to bring cement to surface.Tail volume to be calculated to bring cement to 500' above the shoe.

Production Hole Procedure (2300'± - TD)

Lead: 128 sks: Hi-Lift"G"w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29(cello flakes) mixed at 11.0 ppg, 3.91 ñ3/Sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz "G" w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant),mixed at 14.1 ppg, 1.28 ñ3/Sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.Lead volume to be calculated to bring cement to 200'± above 9-5/8" casing shoe.Tail volume to be calculated to bring cement to 400'± above top of Wasatch.

Final Cement volumes will be based upon qauqe-hole plus 45% excess.

8 point plan-EOG 4/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

9. CEMENT PROGRAM:

Surface Hole Procedure (Surface - 2300'±):

Lead: 150 sks Class "G" cement with 16% Gel, 10 #lsx Gilsonite, 3% Salt, 2% CaCl2,3 lb/sx GR3 ¼ #lsx Flocele mixed at 11 ppg, 3.82 ñ3/Sk. yield, 23 gps water.

Tail: 135 sks Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6 ppg, 1.18 ñ3/Sk.,

5.2 gps water.

Top Out: As necessary with Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6ppg, 1.18 ñ3/Sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculationLead volume to be calculated to bring cement to surface.Tail volume to be calculated to bring cement to 500' above the shoe.

Production Hole Procedure (2300'± - TD)

Lead: 128 sks: Hi-Lift"G"w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29(cello flakes) mixed at 11.0 ppg, 3.91 ñ3/Sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz "G" w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant),mixed at 14.1 ppg, 1.28 ñ3/Sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.Lead volume to be calculated to bring cement to 200'± above 9-5/8" casing shoe.Tail volume to be calculated to bring cement to 400'± above top of Wasatch.

Final Cement volumes will be based upon qauqe-hole plus 45% excess.

8 point plan-EOG 4/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

9. CEMENT PROGRAM:

Surface Hole Procedure (Surface - 2300'±):

Lead: 150 sks Class "G" cement with 16% Gel, 10 #lsx Gilsonite, 3% Salt, 2% CaCl2,3 lb/sx GR3 ¼ #lsx Flocele mixed at 11 ppg, 3.82 ñ3/Sk. yield, 23 gps water.

Tail: 135 sks Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6 ppg, 1.18 ñ3/Sk.,

5.2 gps water.

Top Out: As necessary with Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6ppg, 1.18 ñ3/Sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculationLead volume to be calculated to bring cement to surface.Tail volume to be calculated to bring cement to 500' above the shoe.

Production Hole Procedure (2300'± - TD)

Lead: 128 sks: Hi-Lift"G"w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29(cello flakes) mixed at 11.0 ppg, 3.91 ñ3/Sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz "G" w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant),mixed at 14.1 ppg, 1.28 ñ3/Sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.Lead volume to be calculated to bring cement to 200'± above 9-5/8" casing shoe.Tail volume to be calculated to bring cement to 400'± above top of Wasatch.

Final Cement volumes will be based upon qauqe-hole plus 45% excess.

8 point plan-EOG 4/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

9. CEMENT PROGRAM:

Surface Hole Procedure (Surface - 2300'±):

Lead: 150 sks Class "G" cement with 16% Gel, 10 #lsx Gilsonite, 3% Salt, 2% CaCl2,3 lb/sx GR3 ¼ #lsx Flocele mixed at 11 ppg, 3.82 ñ3/Sk. yield, 23 gps water.

Tail: 135 sks Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6 ppg, 1.18 ñ3/Sk.,

5.2 gps water.

Top Out: As necessary with Class "G" cement with 2% CaCl2, ¼#|Sk Flocele mixed at 15.6ppg, 1.18 ñ3/Sk., 5.2 gps water.

Note: The above number of sacks is based on gauge-hole calculationLead volume to be calculated to bring cement to surface.Tail volume to be calculated to bring cement to 500' above the shoe.

Production Hole Procedure (2300'± - TD)

Lead: 128 sks: Hi-Lift"G"w/12% D20 (Bentonite), 1% D79 (Extender), 5% D44(Salt),0.2% D46 (Antifoam), 0.25% D112 (Fluid Loss Additive), 0.25 pps D29(cello flakes) mixed at 11.0 ppg, 3.91 ñ3/Sk., 24.5 gps water.

Tail: 909 sks: 50:50 Poz "G" w/ 2% D20 (Bentonite), 0.1% D46 (Antifoam), 0.075%D13 (Retarder), 0.2% D167 (Fluid Loss Additive), 0.2% D65 (Dispersant),mixed at 14.1 ppg, 1.28 ñ3/Sk., 5.9gps water.

Note: The above number of sacks is based on gauge-hole calculation.Lead volume to be calculated to bring cement to 200'± above 9-5/8" casing shoe.Tail volume to be calculated to bring cement to 400'± above top of Wasatch.

Final Cement volumes will be based upon qauqe-hole plus 45% excess.

8 point plan-EOG 4/5

Page 16: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

DRILLING PLAN MULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D, CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NW/NW, SEC. 25, T9S, R22E, S.L.B.&M.. UINTAH COUNTY, UTAH

8 point plan-EOG 5/5 7/26/2010

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300’±):

Lost circulation

Production Hole (2300’± - TD):

Sloughing shales, lost circulation and key seat development are possible in the Wasatch Formation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke Manifold B. Upper and Lower Kelly Cock C. Stabbing Valve D. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will be used, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore, no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used, produced, stored, transported, or disposed of in association with the drilling of this well.

13. Air Drilling Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60’ GL or 10’± into competent formation, whichever is deeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drilling superintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10” to help reduce back pressure on the well

bore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

'APIWellNo:43047511750000''APIWellNo:43047511750000'

DRILLING PLAN eogresourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300'±):

Lost circulation

Production Hole (2300'± - TD):

Sloughing shales, lost circulation and key seat development are possible in the WasatchFormation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke ManifoldB. Upper and Lower Kelly CockC. stabbingValveD. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will beused, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore,no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used,produced, stored, transported, or disposed of in association with the drilling of this well.

13.Air Drillinq Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60' GL or 10'± into competent formation, whichever isdeeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drillingsuperintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10" to help reduce back pressure on the wellbore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

8 point plan-EOG 5/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300'±):

Lost circulation

Production Hole (2300'± - TD):

Sloughing shales, lost circulation and key seat development are possible in the WasatchFormation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke ManifoldB. Upper and Lower Kelly CockC. stabbingValveD. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will beused, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore,no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used,produced, stored, transported, or disposed of in association with the drilling of this well.

13.Air Drillinq Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60' GL or 10'± into competent formation, whichever isdeeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drillingsuperintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10" to help reduce back pressure on the wellbore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

8 point plan-EOG 5/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300'±):

Lost circulation

Production Hole (2300'± - TD):

Sloughing shales, lost circulation and key seat development are possible in the WasatchFormation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke ManifoldB. Upper and Lower Kelly CockC. stabbingValveD. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will beused, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore,no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used,produced, stored, transported, or disposed of in association with the drilling of this well.

13.Air Drillinq Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60' GL or 10'± into competent formation, whichever isdeeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drillingsuperintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10" to help reduce back pressure on the wellbore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

8 point plan-EOG 5/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300'±):

Lost circulation

Production Hole (2300'± - TD):

Sloughing shales, lost circulation and key seat development are possible in the WasatchFormation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke ManifoldB. Upper and Lower Kelly CockC. stabbingValveD. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will beused, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore,no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used,produced, stored, transported, or disposed of in association with the drilling of this well.

13.Air Drillinq Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60' GL or 10'± into competent formation, whichever isdeeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drillingsuperintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10" to help reduce back pressure on the wellbore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

8 point plan-EOG 5/5

'APIWellNo:43047511750000'

DRILLING PLAN eogmsourcesMULTI-WELL PAD:

CWU 1535-25D, CWU 1536-25D, CWU 1537-25D,CWU 1538-25D, CWU 1539-25D, CWU 1540-25D

NWINW, SEC. 25, T9S, R22E, S.L.B.&M..UINTAH COUNTY, UTAH

10. ABNORMAL CONDITIONS:

Surface Hole (Surface - 2300'±):

Lost circulation

Production Hole (2300'± - TD):

Sloughing shales, lost circulation and key seat development are possible in the WasatchFormation.

11. STANDARD REQUIRED EQUIPMENT:

A. Choke ManifoldB. Upper and Lower Kelly CockC. stabbingValveD. Visual Mud Monitoring

12. HAZARDOUS CHEMICALS:

No chemicals subject to reporting under SARA title III in an amount equal to or greater than 10,000 pounds will beused, produced, stored, transported, or disposed of annually in association with the drilling of this well. Furthermore,no extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will be used,produced, stored, transported, or disposed of in association with the drilling of this well.

13.Air Drillinq Operations:

1. Main Air Compressors are 1250 CFM 350 psi with 2000 psi Boosters and are rig mounted.

2. Secondary Air Compressors are 1170 CFM 350 psi with 2000 psi Boosters and are rig mounted.

3. Minimum setting depth of conductor casing will be 60' GL or 10'± into competent formation, whichever isdeeper, as determined by the EOG person in charge. Exceptions must be approved by an EOG drillingsuperintendent or manager.

4. The diameter of the diverter flow line will be a minimum of 10" to help reduce back pressure on the wellbore during uncontrolled flow.

5. Rat and Mouse hole drilling will occur only after surface casing has been set and cemented.

6. EOG Resources, Inc. will use a properly maintained and lubricated stripper head.

(Attachment: BOP Schematic Diagram)

8 point plan-EOG 5/5

Page 17: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

EOG RESOURCES INC.CWU #1535-25D, #1536-25D, Ñl537-25D,

#1538-25D, #1539-25D & #1540-25DLOCATED IN UINTAH COUNTY, UTAH

SECTION 25 T9S R22E S.L.B.&M.

PHOTO: VIEW FROM CORNER #5 TO LOCATION STAKES CAMERA ANGLE: NORTHERLY

PHOTO: VIEW OF EXISTING ACCESS CAMERA ANGLE: SOUTHWESTERLY

Uintah Engineering & Land Surveying LOCATIONPHOTos 10 0 8 0 9 PHOTO85 South 200 East Vemal, Utah 84078 ONT DAY YEAR

-Since 1964 - (435) 789-1017 * FAX (435) 789-1813 TAKENBY:G.S. DRAWNBY:Z.L. EVISED:

'APIWellNo:43047511750000'

EOG RESOURCES INC.CWU #1535-25D, #1536-25D, Ñl537-25D,

#1538-25D, #1539-25D & #1540-25DLOCATED IN UINTAH COUNTY, UTAH

SECTION 25 T9S R22E S.L.B.&M.

PHOTO: VIEW FROM CORNER #5 TO LOCATION STAKES CAMERA ANGLE: NORTHERLY

PHOTO: VIEW OF EXISTING ACCESS CAMERA ANGLE: SOUTHWESTERLY

Uintah Engineering & Land Surveying LOCATIONPHOTos 10 0 8 0 9 PHOTO85 South 200 East Vemal, Utah 84078 ONT DAY YEAR

-Since 1964 - (435) 789-1017 * FAX (435) 789-1813 TAKENBY:G.S. DRAWNBY:Z.L. EVISED:

'APIWellNo:43047511750000'

EOG RESOURCES INC.CWU #1535-25D, #1536-25D, Ñl537-25D,

#1538-25D, #1539-25D & #1540-25DLOCATED IN UINTAH COUNTY, UTAH

SECTION 25 T9S R22E S.L.B.&M.

PHOTO: VIEW FROM CORNER #5 TO LOCATION STAKES CAMERA ANGLE: NORTHERLY

PHOTO: VIEW OF EXISTING ACCESS CAMERA ANGLE: SOUTHWESTERLY

Uintah Engineering & Land Surveying LOCATIONPHOTos 10 0 8 0 9 PHOTO85 South 200 East Vemal, Utah 84078 ONT DAY YEAR

-Since 1964 - (435) 789-1017 * FAX (435) 789-1813 TAKENBY:G.S. DRAWNBY:Z.L. EVISED:

'APIWellNo:43047511750000'

EOG RESOURCES INC.CWU #1535-25D, #1536-25D, Ñl537-25D,

#1538-25D, #1539-25D & #1540-25DLOCATED IN UINTAH COUNTY, UTAH

SECTION 25 T9S R22E S.L.B.&M.

PHOTO: VIEW FROM CORNER #5 TO LOCATION STAKES CAMERA ANGLE: NORTHERLY

PHOTO: VIEW OF EXISTING ACCESS CAMERA ANGLE: SOUTHWESTERLY

Uintah Engineering & Land Surveying LOCATIONPHOTos 10 0 8 0 9 PHOTO85 South 200 East Vemal, Utah 84078 ONT DAY YEAR

-Since 1964 - (435) 789-1017 * FAX (435) 789-1813 TAKENBY:G.S. DRAWNBY:Z.L. EVISED:

'APIWellNo:43047511750000'

EOG RESOURCES INC.CWU #1535-25D, #1536-25D, Ñl537-25D,

#1538-25D, #1539-25D & #1540-25DLOCATED IN UINTAH COUNTY, UTAH

SECTION 25 T9S R22E S.L.B.&M.

PHOTO: VIEW FROM CORNER #5 TO LOCATION STAKES CAMERA ANGLE: NORTHERLY

PHOTO: VIEW OF EXISTING ACCESS CAMERA ANGLE: SOUTHWESTERLY

Uintah Engineering & Land Surveying LOCATIONPHOTos 10 0 8 0 9 PHOTO85 South 200 East Vemal, Utah 84078 ONT DAY YEAR

-Since 1964 - (435) 789-1017 * FAX (435) 789-1813 TAKENBY:G.S. DRAWNBY:Z.L. EVISED:

Page 18: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

-o EOG RESOURCES, INC. ISCALE: 1" = 50' LOCATION LAYOUT FOR

FIGURE #1-= DATE: 10-20-09

Drawn By: D.R.B· CWU #1535-25D, #1536-25D, #1537-25D,Rev: 11-16-09 D.R.B #1538-25D, #1539-25D & #1540-25DRev: 12-03-09 D.R.B.

SECTION 25, T9S, R22E, S.L.B.&M.\ / NW 1/4 NW 1/4 Are /

/ uoximum E-6. J'C-4.8 Œsturbance S. 15.5'a- 8. 26.6 i

6 8 /\ / Sta. J+60

50' s / / 5016

NOTE:Elore Pit is to Approx C-1.5' Round corners 5014

be located a rnin. B. 2J.J' as neededof 100' frorn the Cut SlopeWell Head.

Diversion Ditch

^o \ Cut/F///\ Trnesition

06 06C /1539-25D

OF(To CWU /1540-250

Anchor CM/ /143 -25D NO6'46'25"W 644.27(Typ.) W fŠg 2 O (TTBOjfoM HOLE)

CWU /1537-25D

CWU /1536-25DC-1.0 s lo \ 135' Sto. 1+50E/. 22.8' C-0.2'

Existing Pod E-2.8'

Existing Wel /508-25E/. 19.0'

Sta. 0+75 ko Toe ofFill Slope

BorrowArea Sta. 0+00

C-10. C-0.2

E/. J2.1' 22.7' od 19.6'Existing Road Existing Access

Elev. Ungraded Ground at Center of Location = 5022.0' INIIRo

GINEERING & LAND SURVEYING\Einish Graded E/ev. at Center of Location = 5021.8 | 85 So. 200 East * Vernal, Utah 84078 * (436)

'APIWellNo:43047511750000'

-o EOG RESOURCES, INC. ISCALE: 1" = 50' LOCATION LAYOUT FOR

FIGURE #1-= DATE: 10-20-09

Drawn By: D.R.B· CWU #1535-25D, #1536-25D, #1537-25D,Rev: 11-16-09 D.R.B #1538-25D, #1539-25D & #1540-25DRev: 12-03-09 D.R.B.

SECTION 25, T9S, R22E, S.L.B.&M.\ / NW 1/4 NW 1/4 Are /

/ uoximum E-6. J'C-4.8 Œsturbance S. 15.5'a- 8. 26.6 i

6 8 /\ / Sta. J+60

50' s / / 5016

NOTE:Elore Pit is to Approx C-1.5' Round corners 5014

be located a rnin. B. 2J.J' as neededof 100' frorn the Cut Slope

Well Head.Diversion Ditch

^o \ Cut/F///\ Trnesition

06 06C /1539-25D

OF(To CWU /1540-250

Anchor CM/ /143 -25D NO6'46'25"W 644.27(Typ.) W fŠg 2 O (TTBOjfoM HOLE)

CWU /1537-25D

CWU /1536-25DC-1.0 s lo \ 135' Sto. 1+50E/. 22.8' C-0.2'

Existing Pod E-2.8'

Existing Wel /508-25E/. 19.0'

Sta. 0+75 ko Toe ofFill Slope

BorrowArea Sta. 0+00

C-10. C-0.2

E/. J2.1' 22.7' od 19.6'Existing Road Existing Access

Elev. Ungraded Ground at Center of Location = 5022.0' INIIRo

GINEERING & LAND SURVEYING\Einish Graded E/ev. at Center of Location = 5021.8 | 85 So. 200 East * Vernal, Utah 84078 * (436)

'APIWellNo:43047511750000'

-o EOG RESOURCES, INC. ISCALE: 1" = 50' LOCATION LAYOUT FOR

FIGURE #1-= DATE: 10-20-09

Drawn By: D.R.B· CWU #1535-25D, #1536-25D, #1537-25D,Rev: 11-16-09 D.R.B #1538-25D, #1539-25D & #1540-25DRev: 12-03-09 D.R.B.

SECTION 25, T9S, R22E, S.L.B.&M.\ / NW 1/4 NW 1/4 Are /

/ uoximum E-6. J'C-4.8 Œsturbance S. 15.5'a- 8. 26.6 i

6 8 /\ / Sta. J+60

50' s / / 5016

NOTE:Elore Pit is to Approx C-1.5' Round corners 5014

be located a rnin. B. 2J.J' as neededof 100' frorn the Cut Slope

Well Head.Diversion Ditch

^o \ Cut/F///\ Trnesition

06 06C /1539-25D

OF(To CWU /1540-250

Anchor CM/ /143 -25D NO6'46'25"W 644.27(Typ.) W fŠg 2 O (TTBOjfoM HOLE)

CWU /1537-25D

CWU /1536-25DC-1.0 s lo \ 135' Sto. 1+50E/. 22.8' C-0.2'

Existing Pod E-2.8'

Existing Wel /508-25E/. 19.0'

Sta. 0+75 ko Toe ofFill Slope

BorrowArea Sta. 0+00

C-10. C-0.2

E/. J2.1' 22.7' od 19.6'Existing Road Existing Access

Elev. Ungraded Ground at Center of Location = 5022.0' INIIRo

GINEERING & LAND SURVEYING\Einish Graded E/ev. at Center of Location = 5021.8 | 85 So. 200 East * Vernal, Utah 84078 * (436)

'APIWellNo:43047511750000'

-o EOG RESOURCES, INC. ISCALE: 1" = 50' LOCATION LAYOUT FOR

FIGURE #1-= DATE: 10-20-09

Drawn By: D.R.B· CWU #1535-25D, #1536-25D, #1537-25D,Rev: 11-16-09 D.R.B #1538-25D, #1539-25D & #1540-25DRev: 12-03-09 D.R.B.

SECTION 25, T9S, R22E, S.L.B.&M.\ / NW 1/4 NW 1/4 Are /

/ uoximum E-6. J'C-4.8 Œsturbance S. 15.5'a- 8. 26.6 i

6 8 /\ / Sta. J+60

50' s / / 5016

NOTE:Elore Pit is to Approx C-1.5' Round corners 5014

be located a rnin. B. 2J.J' as neededof 100' frorn the Cut Slope

Well Head.Diversion Ditch

^o \ Cut/F///\ Trnesition

06 06C /1539-25D

OF(To CWU /1540-250

Anchor CM/ /143 -25D NO6'46'25"W 644.27(Typ.) W fŠg 2 O (TTBOjfoM HOLE)

CWU /1537-25D

CWU /1536-25DC-1.0 s lo \ 135' Sto. 1+50E/. 22.8' C-0.2'

Existing Pod E-2.8'

Existing Wel /508-25E/. 19.0'

Sta. 0+75 ko Toe ofFill Slope

BorrowArea Sta. 0+00

C-10. C-0.2

E/. J2.1' 22.7' od 19.6'Existing Road Existing Access

Elev. Ungraded Ground at Center of Location = 5022.0' INIIRo

GINEERING & LAND SURVEYING\Einish Graded E/ev. at Center of Location = 5021.8 | 85 So. 200 East * Vernal, Utah 84078 * (436)

'APIWellNo:43047511750000'

-o EOG RESOURCES, INC. ISCALE: 1" = 50' LOCATION LAYOUT FOR

FIGURE #1-= DATE: 10-20-09

Drawn By: D.R.B· CWU #1535-25D, #1536-25D, #1537-25D,Rev: 11-16-09 D.R.B #1538-25D, #1539-25D & #1540-25DRev: 12-03-09 D.R.B.

SECTION 25, T9S, R22E, S.L.B.&M.\ / NW 1/4 NW 1/4 Are /

/ uoximum E-6. J'C-4.8 Œsturbance S. 15.5'a- 8. 26.6 i

6 8 /\ / Sta. J+60

50' s / / 5016

NOTE:Elore Pit is to Approx C-1.5' Round corners 5014

be located a rnin. B. 2J.J' as neededof 100' frorn the Cut Slope

Well Head.Diversion Ditch

^o \ Cut/F///\ Trnesition

06 06C /1539-25D

OF(To CWU /1540-250

Anchor CM/ /143 -25D NO6'46'25"W 644.27(Typ.) W fŠg 2 O (TTBOjfoM HOLE)

CWU /1537-25D

CWU /1536-25DC-1.0 s lo \ 135' Sto. 1+50E/. 22.8' C-0.2'

Existing Pod E-2.8'

Existing Wel /508-25E/. 19.0'

Sta. 0+75 ko Toe ofFill Slope

BorrowArea Sta. 0+00

C-10. C-0.2

E/. J2.1' 22.7' od 19.6'Existing Road Existing Access

Elev. Ungraded Ground at Center of Location = 5022.0' INIIRo

GINEERING & LAND SURVEYING\Einish Graded E/ev. at Center of Location = 5021.8 | 85 So. 200 East * Vernal, Utah 84078 * (436)

Page 19: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''A IWellNo:43047511750000'

159EOG RESOURCES, INC. 9 LAND

TYPICAL CROSS SECTIONS FOR×-Section CWU #1535-25D, #1536-25D, #1537-25D,

, o No. 1scale #1538-25D, #1539-25D & #1540-25D

1" =So, SECTION 25, T9S, R22E, S.L.B.&M. AY

NW 1/4 NW 1/4 ¡ iDATE: 10-20-09 FIGURE #2 Te a- 0Drawn By' D.R.B. ggg

Rev: 12-03-09 D.R.B. 50' 135'

inished Gradei CUT /

¯llylllmlllmlll ll III¯"' ' L \

SM. J+60

PreconstructionGrade 110 135

Slope= 1 1/2: 1

SM. 1+50

110' 135'

SM. 0+75

-

,110'

, ,135'

APPROX/MATE ACREAGES SM. 0+00

EX/SE WELLS/TE D/S7URBANCE = ±1.280 ACRESNEW WELLS/TE D/STURBANCE = ±0.933 ACRES(New Construction Only) * NOTE

E/LL QUANT/TYINCLUDESACCESS ROAD D/S7URBANCE = ±0.059 ACRES 5X FOR COMPACT/ON

TOTAL = ±2.272 ACRES

APPROXIMATE YARDAGES EXCESS MATERIAL = 680 Cu. Yds.

(6") Topsoil Stripping = 680 Cu. Yds. Topsoil = 680 Cu. Yds.

(New Construction Only)EXCESS UNBALANCE = 0 Cu. Yds.

Remaining Location = 2,150 Cu. Yds· (After Rehabilitation)TOTAL CUT = 2,830 CU.YDS.FILL =2,150 CU.YDS. UINTAH ENGINEERING & LAND SURVEYING

85 So. 200 East * Vernal, Utah 84078 * (435)

'A IWellNo:43047511750000'

159EOG RESOURCES, INC. 9 LAND

TYPICAL CROSS SECTIONS FOR×-Section CWU #1535-25D, #1536-25D, #1537-25D,

, o No. 1scale #1538-25D, #1539-25D & #1540-25D

1" =So, SECTION 25, T9S, R22E, S.L.B.&M. AY

NW 1/4 NW 1/4 ¡ iDATE: 10-20-09 FIGURE #2 Te a- 0Drawn By' D.R.B. ggg

Rev: 12-03-09 D.R.B. 50' 135'

inished Gradei CUT /

¯llylllmlllmlll ll III¯"' ' L \

SM. J+60

PreconstructionGrade 110 135

Slope= 1 1/2: 1

SM. 1+50

110' 135'

SM. 0+75

-

,110'

, ,135'

APPROX/MATE ACREAGES SM. 0+00

EX/SE WELLS/TE D/S7URBANCE = ±1.280 ACRESNEW WELLS/TE D/STURBANCE = ±0.933 ACRES(New Construction Only) * NOTE

E/LL QUANT/TYINCLUDESACCESS ROAD D/S7URBANCE = ±0.059 ACRES 5X FOR COMPACT/ON

TOTAL = ±2.272 ACRES

APPROXIMATE YARDAGES EXCESS MATERIAL = 680 Cu. Yds.

(6") Topsoil Stripping = 680 Cu. Yds. Topsoil = 680 Cu. Yds.

(New Construction Only)EXCESS UNBALANCE = 0 Cu. Yds.

Remaining Location = 2,150 Cu. Yds· (After Rehabilitation)TOTAL CUT = 2,830 CU.YDS.FILL =2,150 CU.YDS. UINTAH ENGINEERING & LAND SURVEYING

85 So. 200 East * Vernal, Utah 84078 * (435)

'A IWellNo:43047511750000'

159EOG RESOURCES, INC. 9 LAND

TYPICAL CROSS SECTIONS FOR×-Section CWU #1535-25D, #1536-25D, #1537-25D,

, o No. 1scale #1538-25D, #1539-25D & #1540-25D

1" =So, SECTION 25, T9S, R22E, S.L.B.&M. AY

NW 1/4 NW 1/4 ¡ iDATE: 10-20-09 FIGURE #2 Te a- 0Drawn By' D.R.B. ggg

Rev: 12-03-09 D.R.B. 50' 135'

inished Gradei CUT /

¯llylllmlllmlll ll III¯"' ' L \

SM. J+60

PreconstructionGrade 110 135

Slope= 1 1/2: 1

SM. 1+50

110' 135'

SM. 0+75

-

,110'

, ,135'

APPROX/MATE ACREAGES SM. 0+00

EX/SE WELLS/TE D/S7URBANCE = ±1.280 ACRESNEW WELLS/TE D/STURBANCE = ±0.933 ACRES(New Construction Only) * NOTE

E/LL QUANT/TYINCLUDESACCESS ROAD D/S7URBANCE = ±0.059 ACRES 5X FOR COMPACT/ON

TOTAL = ±2.272 ACRES

APPROXIMATE YARDAGES EXCESS MATERIAL = 680 Cu. Yds.

(6") Topsoil Stripping = 680 Cu. Yds. Topsoil = 680 Cu. Yds.

(New Construction Only)EXCESS UNBALANCE = 0 Cu. Yds.

Remaining Location = 2,150 Cu. Yds· (After Rehabilitation)TOTAL CUT = 2,830 CU.YDS.FILL =2,150 CU.YDS. UINTAH ENGINEERING & LAND SURVEYING

85 So. 200 East * Vernal, Utah 84078 * (435)

'A IWellNo:43047511750000'

159EOG RESOURCES, INC. 9 LAND

TYPICAL CROSS SECTIONS FOR×-Section CWU #1535-25D, #1536-25D, #1537-25D,

, o No. 1scale #1538-25D, #1539-25D & #1540-25D

1" =So, SECTION 25, T9S, R22E, S.L.B.&M. AY

NW 1/4 NW 1/4 ¡ iDATE: 10-20-09 FIGURE #2 Te a- 0Drawn By' D.R.B. ggg

Rev: 12-03-09 D.R.B. 50' 135'

inished Gradei CUT /

¯llylllmlllmlll ll III¯"' ' L \

SM. J+60

PreconstructionGrade 110 135

Slope= 1 1/2: 1

SM. 1+50

110' 135'

SM. 0+75

-

,110'

, ,135'

APPROX/MATE ACREAGES SM. 0+00

EX/SE WELLS/TE D/S7URBANCE = ±1.280 ACRESNEW WELLS/TE D/STURBANCE = ±0.933 ACRES(New Construction Only) * NOTE

E/LL QUANT/TYINCLUDESACCESS ROAD D/S7URBANCE = ±0.059 ACRES 5X FOR COMPACT/ON

TOTAL = ±2.272 ACRES

APPROXIMATE YARDAGES EXCESS MATERIAL = 680 Cu. Yds.

(6") Topsoil Stripping = 680 Cu. Yds. Topsoil = 680 Cu. Yds.

(New Construction Only)EXCESS UNBALANCE = 0 Cu. Yds.

Remaining Location = 2,150 Cu. Yds· (After Rehabilitation)TOTAL CUT = 2,830 CU.YDS.FILL =2,150 CU.YDS. UINTAH ENGINEERING & LAND SURVEYING

85 So. 200 East * Vernal, Utah 84078 * (435)

'A IWellNo:43047511750000'

159EOG RESOURCES, INC. 9 LAND

TYPICAL CROSS SECTIONS FOR×-Section CWU #1535-25D, #1536-25D, #1537-25D,

, o No. 1scale #1538-25D, #1539-25D & #1540-25D

1" =So, SECTION 25, T9S, R22E, S.L.B.&M. AY

NW 1/4 NW 1/4 ¡ iDATE: 10-20-09 FIGURE #2 Te a- 0Drawn By' D.R.B. ggg

Rev: 12-03-09 D.R.B. 50' 135'

inished Gradei CUT /

¯llylllmlllmlll ll III¯"' ' L \

SM. J+60

PreconstructionGrade 110 135

Slope= 1 1/2: 1

SM. 1+50

110' 135'

SM. 0+75

-

,110'

, ,135'

APPROX/MATE ACREAGES SM. 0+00

EX/SE WELLS/TE D/S7URBANCE = ±1.280 ACRESNEW WELLS/TE D/STURBANCE = ±0.933 ACRES(New Construction Only) * NOTE

E/LL QUANT/TYINCLUDESACCESS ROAD D/S7URBANCE = ±0.059 ACRES 5X FOR COMPACT/ON

TOTAL = ±2.272 ACRES

APPROXIMATE YARDAGES EXCESS MATERIAL = 680 Cu. Yds.

(6") Topsoil Stripping = 680 Cu. Yds. Topsoil = 680 Cu. Yds.

(New Construction Only)EXCESS UNBALANCE = 0 Cu. Yds.

Remaining Location = 2,150 Cu. Yds· (After Rehabilitation)TOTAL CUT = 2,830 CU.YDS.FILL =2,150 CU.YDS. UINTAH ENGINEERING & LAND SURVEYING

85 So. 200 East * Vernal, Utah 84078 * (435)

Page 20: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

EOG RESOURCES, INC. FIGURE #3TYPICAL RIG LAYOUT FOR

CWU #1535-25D, #1536-25D, #1537-25D,p LAND#1538-25D, #1539-25D & #1540-25D

,DSCAELE:1 0-5009 SECTION 25, T9S, R22E, S.L.B.&M.

No. 1 1Drawn By D.R.B. NW 1/4 NW 1/4 o.

Rev: 12-03-09 D.R.B.

50' #g

^o

NO TE:Elore Pit is tobe located a min.of 100' from theWell Head.

Flare PitPIPE RACKS

.lo CWU /15J9-25DQ

ToCWU /1540-25Diioliii

.ToCWU /1538-25Doin CM/ /15J5-25D

- 6 CWU /15J7-25DCWU f1536-25D

110'_DO_GjHOUSE 135'

PUMP¯

xisting Well /508-25E-

MUD SHED TOILET

| HOPPER

| | POWER li

o | | TOOLS

I I FUEL STORAGE

TR SH

TANK

UINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC. FIGURE #3TYPICAL RIG LAYOUT FOR

CWU #1535-25D, #1536-25D, #1537-25D,p LAND#1538-25D, #1539-25D & #1540-25D

,DSCAELE:1 0-5009 SECTION 25, T9S, R22E, S.L.B.&M.

No. 1 1Drawn By D.R.B. NW 1/4 NW 1/4 o.

Rev: 12-03-09 D.R.B.

50' #g

^o

NO TE:Elore Pit is tobe located a min.of 100' from theWell Head.

Flare PitPIPE RACKS

.lo CWU /15J9-25DQ

ToCWU /1540-25Diioliii

.ToCWU /1538-25Doin CM/ /15J5-25D

- 6 CWU /15J7-25DCWU f1536-25D

110'_DO_GjHOUSE 135'

PUMP¯

xisting Well /508-25E-

MUD SHED TOILET

| HOPPER

| | POWER li

o | | TOOLS

I I FUEL STORAGE

TR SH

TANK

UINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC. FIGURE #3TYPICAL RIG LAYOUT FOR

CWU #1535-25D, #1536-25D, #1537-25D,p LAND#1538-25D, #1539-25D & #1540-25D

,DSCAELE:1 0-5009 SECTION 25, T9S, R22E, S.L.B.&M.

No. 1 1Drawn By D.R.B. NW 1/4 NW 1/4 o.

Rev: 12-03-09 D.R.B.

50' #g

^o

NO TE:Elore Pit is tobe located a min.of 100' from theWell Head.

Flare PitPIPE RACKS

.lo CWU /15J9-25DQ

ToCWU /1540-25Diioliii

.ToCWU /1538-25Doin CM/ /15J5-25D

- 6 CWU /15J7-25DCWU f1536-25D

110'_DO_GjHOUSE 135'

PUMP¯

xisting Well /508-25E-

MUD SHED TOILET

| HOPPER

| | POWER li

o | | TOOLS

I I FUEL STORAGE

TR SH

TANK

UINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC. FIGURE #3TYPICAL RIG LAYOUT FOR

CWU #1535-25D, #1536-25D, #1537-25D,p LAND#1538-25D, #1539-25D & #1540-25D

,DSCAELE:1 0-5009 SECTION 25, T9S, R22E, S.L.B.&M.

No. 1 1Drawn By D.R.B. NW 1/4 NW 1/4 o.

Rev: 12-03-09 D.R.B.

50' #g

^o

NO TE:Elore Pit is tobe located a min.of 100' from theWell Head.

Flare PitPIPE RACKS

.lo CWU /15J9-25DQ

ToCWU /1540-25Diioliii

.ToCWU /1538-25Doin CM/ /15J5-25D

- 6 CWU /15J7-25DCWU f1536-25D

110'_DO_GjHOUSE 135'

PUMP¯

xisting Well /508-25E-

MUD SHED TOILET

| HOPPER

| | POWER li

o | | TOOLS

I I FUEL STORAGE

TR SH

TANK

UINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC. FIGURE #3TYPICAL RIG LAYOUT FOR

CWU #1535-25D, #1536-25D, #1537-25D,p LAND#1538-25D, #1539-25D & #1540-25D

,DSCAELE:1 0-5009 SECTION 25, T9S, R22E, S.L.B.&M.

No. 1 1Drawn By D.R.B. NW 1/4 NW 1/4 o.

Rev: 12-03-09 D.R.B.

50' #g

^o

NO TE:Elore Pit is tobe located a min.of 100' from theWell Head.

Flare PitPIPE RACKS

.lo CWU /15J9-25DQ

ToCWU /1540-25Diioliii

.ToCWU /1538-25Doin CM/ /15J5-25D

- 6 CWU /15J7-25DCWU f1536-25D

110'_DO_GjHOUSE 135'

PUMP¯

xisting Well /508-25E-

MUD SHED TOILET

| HOPPER

| | POWER li

o | | TOOLS

I I FUEL STORAGE

TR SH

TANK

UINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

Page 21: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

EOG RESOURCES, INC· FIGURE #4PRODUCTION FACILITY LAYOUT FOR '

CWU #1535-25D, #1536-25D, #1537-25D,p LAND

,#1538-25D, #1539-25D & #1540-25D

SCALE: 1 = 50DATE: 10-20-09 SECTION 25, T9S, R22E, S.L.B.&M. 3 No. 1Drawn By D.R.B. NW 1/4 NW 1/4 22 on

Rev: 12-03-09 D.R.B.

BERM

COMBOUNIT c

IQ.

IIIIIIIII

CWU /1539-250CWU /1540-250

CWU /15JB-25DCWU /15J5-25D

CWU /15J7-25D

ACWU /15J6-25D

e Existing We// f508-25F

Access Road

RE-HABED AREAUINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC· FIGURE #4PRODUCTION FACILITY LAYOUT FOR '

CWU #1535-25D, #1536-25D, #1537-25D,p LAND

,#1538-25D, #1539-25D & #1540-25D

SCALE: 1 = 50DATE: 10-20-09 SECTION 25, T9S, R22E, S.L.B.&M. 3 No. 1Drawn By D.R.B. NW 1/4 NW 1/4 22 on

Rev: 12-03-09 D.R.B.

BERM

COMBOUNIT c

IQ.

IIIIIIIII

CWU /1539-250CWU /1540-250

CWU /15JB-25DCWU /15J5-25D

CWU /15J7-25D

ACWU /15J6-25D

e Existing We// f508-25F

Access Road

RE-HABED AREAUINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC· FIGURE #4PRODUCTION FACILITY LAYOUT FOR '

CWU #1535-25D, #1536-25D, #1537-25D,p LAND

,#1538-25D, #1539-25D & #1540-25D

SCALE: 1 = 50DATE: 10-20-09 SECTION 25, T9S, R22E, S.L.B.&M. 3 No. 1Drawn By D.R.B. NW 1/4 NW 1/4 22 on

Rev: 12-03-09 D.R.B.

BERM

COMBOUNIT c

IQ.

IIIIIIIII

CWU /1539-250CWU /1540-250

CWU /15JB-25DCWU /15J5-25D

CWU /15J7-25D

ACWU /15J6-25D

e Existing We// f508-25F

Access Road

RE-HABED AREAUINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC· FIGURE #4PRODUCTION FACILITY LAYOUT FOR '

CWU #1535-25D, #1536-25D, #1537-25D,p LAND

,#1538-25D, #1539-25D & #1540-25D

SCALE: 1 = 50DATE: 10-20-09 SECTION 25, T9S, R22E, S.L.B.&M. 3 No. 1Drawn By D.R.B. NW 1/4 NW 1/4 22 on

Rev: 12-03-09 D.R.B.

BERM

COMBOUNIT c

IQ.

IIIIIIIII

CWU /1539-250CWU /1540-250

CWU /15JB-25DCWU /15J5-25D

CWU /15J7-25D

ACWU /15J6-25D

e Existing We// f508-25F

Access Road

RE-HABED AREAUINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

'APIWellNo:43047511750000'

EOG RESOURCES, INC· FIGURE #4PRODUCTION FACILITY LAYOUT FOR '

CWU #1535-25D, #1536-25D, #1537-25D,p LAND

,#1538-25D, #1539-25D & #1540-25D

SCALE: 1 = 50DATE: 10-20-09 SECTION 25, T9S, R22E, S.L.B.&M. 3 No. 1Drawn By D.R.B. NW 1/4 NW 1/4 22 on

Rev: 12-03-09 D.R.B.

BERM

COMBOUNIT c

IQ.

IIIIIIIII

CWU /1539-250CWU /1540-250

CWU /15JB-25DCWU /15J5-25D

CWU /15J7-25D

ACWU /15J6-25D

e Existing We// f508-25F

Access Road

RE-HABED AREAUINTAH ENGINEERING & LAND SURVEYING85 So. 200 East * Vernal, Utah 84078 * (435)

Page 22: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

EOG RESOURCES, INC. CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25D SECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S. HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATE HIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTION APPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN A SOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGE ROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST; TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTION APPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN AN EASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTION APPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLY DIRECTION APPROXIMATELY 100’ TO THE PROPOSED LOCATION. TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELL LOCATION IS APPROXIMATELY 50.5 MILES.

'APIWellNo:43047511750000''APIWellNo:43047511750000'

EOG RESOURCES, INC.CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S.HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATEHIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGEROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THEEAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTIONAPPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OFTHIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT ANDPROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THEJUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST;TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTIONAPPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN ANEASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THESOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLYDIRECTION APPROXIMATELY 100' TO THE PROPOSED LOCATION.

TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELLLOCATION IS APPROXIMATELY 50.5

'APIWellNo:43047511750000'

EOG RESOURCES, INC.CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S.HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATEHIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGEROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THEEAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTIONAPPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OFTHIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT ANDPROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THEJUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST;TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTIONAPPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN ANEASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THESOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLYDIRECTION APPROXIMATELY 100' TO THE PROPOSED LOCATION.

TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELLLOCATION IS APPROXIMATELY 50.5

'APIWellNo:43047511750000'

EOG RESOURCES, INC.CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S.HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATEHIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGEROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THEEAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTIONAPPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OFTHIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT ANDPROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THEJUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST;TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTIONAPPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN ANEASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THESOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLYDIRECTION APPROXIMATELY 100' TO THE PROPOSED LOCATION.

TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELLLOCATION IS APPROXIMATELY 50.5

'APIWellNo:43047511750000'

EOG RESOURCES, INC.CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S.HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATEHIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGEROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THEEAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTIONAPPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OFTHIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT ANDPROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THEJUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST;TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTIONAPPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN ANEASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THESOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLYDIRECTION APPROXIMATELY 100' TO THE PROPOSED LOCATION.

TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELLLOCATION IS APPROXIMATELY 50.5

'APIWellNo:43047511750000'

EOG RESOURCES, INC.CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E, S.L.B.&M.

PROCEED IN A WESTERLY DIRECTION FROM VERNAL, UTAH ALONG U.S.HIGHWAY 40 APPROXIMATELY 14.0 MILES TO THE JUNCTION OF STATEHIGHWAY 88; EXIT LEFT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 17.0 MILES TO OURAY, UTAH; PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 0.3 MILES ON THE SEEP RIDGEROAD TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THEEAST; TURN LEFT AND PROCEED IN AN EASTERLY DIRECTIONAPPROXIMATELY 12.3 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE SOUTH; TURN RIGHT AND PROCEED IN ASOUTHERLY DIRECTION APPROXIMATELY 1.7 MILES TO THE JUNCTION OFTHIS ROAD AND AN EXISTING ROAD TO THE EAST; TURN LEFT ANDPROCEED IN AN EASTERLY DIRECTION APPROXIMATELY 1.9 MILES TO THEJUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THE SOUTHEAST;TURN RIGHT AND PROCEED IN A SOUTHEASTERLY DIRECTIONAPPROXIMATELY 0.5 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING ROAD TO THE EAST; TURN LEFT AND PROCEED IN ANEASTERLY, THEN SOUTHEASTERLY DIRECTION APPROXIMATELY 1.9MILES TO THE JUNCTION OF THIS ROAD AND AN EXISTING ROAD TO THESOUTH; TURN RIGHT AND PROCEED IN A SOUTHERLY DIRECTIONAPPROXIMATELY 0.9 MILES TO THE JUNCTION OF THIS ROAD AND ANEXISTING TO THE WEST; TURN RIGHT AND PROCEED IN A WESTERLYDIRECTION APPROXIMATELY 100' TO THE PROPOSED LOCATION.

TOTAL DISTANCE FROM VERNAL, UTAH TO THE PROPOSED WELLLOCATION IS APPROXIMATELY 50.5

Page 23: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D

#1539-25D & # 540-2

LEGEND: EOG RESOURCES, INC.N CWU #1535-25D, #1536-25D, #1537-25D,O•PROPOSED LOCATION #1538-25D, #1539-25D & #1540-25D

SECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D

#1539-25D & # 540-2

LEGEND: EOG RESOURCES, INC.N CWU #1535-25D, #1536-25D, #1537-25D,O•PROPOSED LOCATION #1538-25D, #1539-25D & #1540-25D

SECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D

#1539-25D & # 540-2

LEGEND: EOG RESOURCES, INC.N CWU #1535-25D, #1536-25D, #1537-25D,O•PROPOSED LOCATION #1538-25D, #1539-25D & #1540-25D

SECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D

#1539-25D & # 540-2

LEGEND: EOG RESOURCES, INC.N CWU #1535-25D, #1536-25D, #1537-25D,O•PROPOSED LOCATION #1538-25D, #1539-25D & #1540-25D

SECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D

#1539-25D & # 540-2

LEGEND: EOG RESOURCES, INC.N CWU #1535-25D, #1536-25D, #1537-25D,O•PROPOSED LOCATION #1538-25D, #1539-25D & #1540-25D

SECTION 25, T9S, R22E,

Page 24: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

62 -URAY 1 +A

23

0.9 MI. +

MO O' +

30

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D,#1538-25D, #1539-25D & #1540-25D

L 'I « Y

T9 ' ¯

LEGEND: EOG RESOURCES, INC.EXISTINGROAD N CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

62 -URAY 1 +A

23

0.9 MI. +

MO O' +

30

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D,#1538-25D, #1539-25D & #1540-25D

L 'I « Y

T9 ' ¯

LEGEND: EOG RESOURCES, INC.EXISTINGROAD N CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

62 -URAY 1 +A

23

0.9 MI. +

MO O' +

30

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D,#1538-25D, #1539-25D & #1540-25D

L 'I « Y

T9 ' ¯

LEGEND: EOG RESOURCES, INC.EXISTINGROAD N CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

62 -URAY 1 +A

23

0.9 MI. +

MO O' +

30

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D,#1538-25D, #1539-25D & #1540-25D

L 'I « Y

T9 ' ¯

LEGEND: EOG RESOURCES, INC.EXISTINGROAD N CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E,

'APIWellNo:43047511750000'

62 -URAY 1 +A

23

0.9 MI. +

MO O' +

30

PROPOSED LOCATION:CWU #1535-25D, #1536-25D, #1537-25D,#1538-25D, #1539-25D & #1540-25D

L 'I « Y

T9 ' ¯

LEGEND: EOG RESOURCES, INC.EXISTINGROAD N CWU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DSECTION 25, T9S, R22E,

Page 25: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

'APIWellNo:43047511750000''APIWellNo:43047511750000'

62

1207-24

35 _r

348-23N.24 ii Ho

287-23N #927-24 92 24 #12 -24F23 e 23

#435-24N #913-2 0 F23

900- #930-2FM44-23N 464·23 327-2 14-24 929-24

#462-24F#1043 23 #925-2355 H25-23

#1291 2era #1355 23_- #13 26 ___ #129 25

suos-asrsy .2ssess.2*1g250 as

N 25 8759-2586

5 #76 2

# 5

sees N809 25 #7¾25

L ¯ gggg.gggg¶gg #81 I-28 & #034 IGN ,

¯895·26

#1361-25i g #1322-25D #811-25X _ f

288-26 #90 26 y#933-25 25 #65&È

#480·26F -,

#1074·21 s#408·25N # # l 8588-25N

e, ¯I -, #1079 25 81078-25

347-2L

M 2698 9·25 # 25

L #507 F 830 -26 #1081-25 #¶08 25 3 81077·25

PROPOSED LOCATION: es22-secCWU #1535-25D, #1536-25D, #1537-25D,

1 38 D 5D

LEGEND: EOG RESOURCES, INC.DISPOSAL MTLLS WATER RTLLS N cwU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DO PRODUCINGWELLS ABANDONED WELLSSECTION 25, T9S, R22E, S.L.B.&M.

SHUT IN WELLS - - TEMPORARILY

'APIWellNo:43047511750000'

62

1207-24

35 _r

348-23N.24 ii Ho

287-23N #927-24 92 24 #12 -24F23 e 23

#435-24N #913-2 0 F23

900- #930-2FM44-23N 464·23 327-2 14-24 929-24

#462-24F#1043 23 #925-2355 H25-23

#1291 2era #1355 23_- #13 26 ___ #129 25

suos-asrsy .2ssess.2*1g250 as

N 25 8759-2586

5 #76 2

# 5

sees N809 25 #7¾25

L ¯ gggg.gggg¶gg #81 I-28 & #034 IGN ,

¯895·26

#1361-25i g #1322-25D #811-25X _ f

288-26 #90 26 y#933-25 25 #65&È

#480·26F -,

#1074·21 s#408·25N # # l 8588-25N

e, ¯I -, #1079 25 81078-25

347-2L

M 2698 9·25 # 25

L #507 F 830 -26 #1081-25 #¶08 25 3 81077·25

PROPOSED LOCATION: es22-secCWU #1535-25D, #1536-25D, #1537-25D,

1 38 D 5D

LEGEND: EOG RESOURCES, INC.DISPOSAL MTLLS WATER RTLLS N cwU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DO PRODUCINGWELLS ABANDONED WELLSSECTION 25, T9S, R22E, S.L.B.&M.

SHUT IN WELLS - - TEMPORARILY

'APIWellNo:43047511750000'

62

1207-24

35 _r

348-23N.24 ii Ho

287-23N #927-24 92 24 #12 -24F23 e 23

#435-24N #913-2 0 F23

900- #930-2FM44-23N 464·23 327-2 14-24 929-24

#462-24F#1043 23 #925-2355 H25-23

#1291 2era #1355 23_- #13 26 ___ #129 25

suos-asrsy .2ssess.2*1g250 as

N 25 8759-2586

5 #76 2

# 5

sees N809 25 #7¾25

L ¯ gggg.gggg¶gg #81 I-28 & #034 IGN ,

¯895·26

#1361-25i g #1322-25D #811-25X _ f

288-26 #90 26 y#933-25 25 #65&È

#480·26F -,

#1074·21 s#408·25N # # l 8588-25N

e, ¯I -, #1079 25 81078-25

347-2L

M 2698 9·25 # 25

L #507 F 830 -26 #1081-25 #¶08 25 3 81077·25

PROPOSED LOCATION: es22-secCWU #1535-25D, #1536-25D, #1537-25D,

1 38 D 5D

LEGEND: EOG RESOURCES, INC.DISPOSAL MTLLS WATER RTLLS N cwU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DO PRODUCINGWELLS ABANDONED WELLSSECTION 25, T9S, R22E, S.L.B.&M.

SHUT IN WELLS - - TEMPORARILY

'APIWellNo:43047511750000'

62

1207-24

35 _r

348-23N.24 ii Ho

287-23N #927-24 92 24 #12 -24F23 e 23

#435-24N #913-2 0 F23

900- #930-2FM44-23N 464·23 327-2 14-24 929-24

#462-24F#1043 23 #925-2355 H25-23

#1291 2era #1355 23_- #13 26 ___ #129 25

suos-asrsy .2ssess.2*1g250 as

N 25 8759-2586

5 #76 2

# 5

sees N809 25 #7¾25

L ¯ gggg.gggg¶gg #81 I-28 & #034 IGN ,

¯895·26

#1361-25i g #1322-25D #811-25X _ f

288-26 #90 26 y#933-25 25 #65&È

#480·26F -,

#1074·21 s#408·25N # # l 8588-25N

e, ¯I -, #1079 25 81078-25

347-2L

M 2698 9·25 # 25

L #507 F 830 -26 #1081-25 #¶08 25 3 81077·25

PROPOSED LOCATION: es22-secCWU #1535-25D, #1536-25D, #1537-25D,

1 38 D 5D

LEGEND: EOG RESOURCES, INC.DISPOSAL MTLLS WATER RTLLS N cwU #1535-25D, #1536-25D, #1537-25D,

#1538-25D, #1539-25D & #1540-25DO PRODUCINGWELLS ABANDONED WELLSSECTION 25, T9S, R22E, S.L.B.&M.

SHUT IN WELLS - - TEMPORARILY

Page 26: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Chapita Wells Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

NWNW, Section 25, T9S, R22E Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acres

more or less. New surface disturbance associated with the well pad is estimated to be

0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attached TOPO Map “B” showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah –

See attached TOPO Map “A”.

C. Refer to attached Topographic Map “A” showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCESS ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to access the proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, or

vehicle parking.

All travel will be confined to existing access road rights-of-way. Traveling off the 30-foot right-of-way will not be allowed. The access road and associated drainage structures will be maintained in accordance with road guidelines contained in the joint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration and Development, Fourth Edition, and/or BLM Manual Section 9113 concerning road construction standards on projects subject to federal jurisdiction. During the drilling and production phase of operations, the road surface and shoulders will be kept in a safe and useable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION OF EXISTING WELLS WITHIN A ONE-MILE RADIUS:

See attached TOPO map “C” for the location of wells within a one-mile radius.

'APIWellNo:43047511750000''APIWellNo:43047511750000'

eog resources

Chapita We/Is Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DNWNW, Section 25, T9S, R22E

Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acresmore or less. New surface disturbance associated with the well pad is estimated to be0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attachedTOPO Map "B"showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah --

See attached TOPO Map "A".

C. Refer to attached Topographic Map "A"showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCEss ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to accessthe proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, orvehicle parking.

All travel will be confined to existing access road rights-of-way.

Traveling off the 30-foot right-of-way will not be allowed. The access road and associateddrainage structures will be maintained in accordance with road guidelines contained in thejoint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration andDevelopment, Fourth Edition, and/or BLMManual Section 9113 concerning roadconstruction standards on projects subject to federal jurisdiction. During the drilling andproduction phase of operations, the road surface and shoulders will be kept in a safe anduseable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION oF EXISTING WELLs WITHIN A ONE-MILE RADIUS:

See attached TOPO map "C" for the location of wells within a one-mile

'APIWellNo:43047511750000'

eog resources

Chapita We/Is Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DNWNW, Section 25, T9S, R22E

Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acresmore or less. New surface disturbance associated with the well pad is estimated to be0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attachedTOPO Map "B"showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah --

See attached TOPO Map "A".

C. Refer to attached Topographic Map "A"showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCEss ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to accessthe proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, orvehicle parking.

All travel will be confined to existing access road rights-of-way.

Traveling off the 30-foot right-of-way will not be allowed. The access road and associateddrainage structures will be maintained in accordance with road guidelines contained in thejoint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration andDevelopment, Fourth Edition, and/or BLMManual Section 9113 concerning roadconstruction standards on projects subject to federal jurisdiction. During the drilling andproduction phase of operations, the road surface and shoulders will be kept in a safe anduseable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION oF EXISTING WELLs WITHIN A ONE-MILE RADIUS:

See attached TOPO map "C" for the location of wells within a one-mile

'APIWellNo:43047511750000'

eog resources

Chapita We/Is Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DNWNW, Section 25, T9S, R22E

Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acresmore or less. New surface disturbance associated with the well pad is estimated to be0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attachedTOPO Map "B"showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah --

See attached TOPO Map "A".

C. Refer to attached Topographic Map "A"showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCEss ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to accessthe proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, orvehicle parking.

All travel will be confined to existing access road rights-of-way.

Traveling off the 30-foot right-of-way will not be allowed. The access road and associateddrainage structures will be maintained in accordance with road guidelines contained in thejoint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration andDevelopment, Fourth Edition, and/or BLMManual Section 9113 concerning roadconstruction standards on projects subject to federal jurisdiction. During the drilling andproduction phase of operations, the road surface and shoulders will be kept in a safe anduseable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION oF EXISTING WELLs WITHIN A ONE-MILE RADIUS:

See attached TOPO map "C" for the location of wells within a one-mile

'APIWellNo:43047511750000'

eog resources

Chapita We/Is Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DNWNW, Section 25, T9S, R22E

Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acresmore or less. New surface disturbance associated with the well pad is estimated to be0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attachedTOPO Map "B"showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah --

See attached TOPO Map "A".

C. Refer to attached Topographic Map "A"showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCEss ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to accessthe proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, orvehicle parking.

All travel will be confined to existing access road rights-of-way.

Traveling off the 30-foot right-of-way will not be allowed. The access road and associateddrainage structures will be maintained in accordance with road guidelines contained in thejoint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration andDevelopment, Fourth Edition, and/or BLMManual Section 9113 concerning roadconstruction standards on projects subject to federal jurisdiction. During the drilling andproduction phase of operations, the road surface and shoulders will be kept in a safe anduseable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION oF EXISTING WELLs WITHIN A ONE-MILE RADIUS:

See attached TOPO map "C" for the location of wells within a one-mile

'APIWellNo:43047511750000'

eog resources

Chapita We/Is Unit 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DNWNW, Section 25, T9S, R22E

Uintah County, Utah

SURFACE USE PLAN

The well pad is approximately 360 feet long with a 245-foot width, containing 2.08 acresmore or less. New surface disturbance associated with the well pad is estimated to be0.93 acres.

1. EXISTING ROADS:

A. See attached Plats showing directional reference stakes on location, and attachedTOPO Map "B"showing access to location from existing roads.

B. The proposed well site is located approximately 50.5 miles south of Vernal, Utah --

See attached TOPO Map "A".

C. Refer to attached Topographic Map "A"showing labeled access route to location.

D. Existing roads will be maintained and repaired as necessary.

2. PLANNED ACCEss ROAD:

A. The existing access road for the producing well CWU 508-25F will be used to accessthe proposed locations.

B. No additional storage areas will be needed for storing equipment, stockpiling, orvehicle parking.

All travel will be confined to existing access road rights-of-way.

Traveling off the 30-foot right-of-way will not be allowed. The access road and associateddrainage structures will be maintained in accordance with road guidelines contained in thejoint BLM/USFS publication: Surface Operating Standards for Oil and Gas Exploration andDevelopment, Fourth Edition, and/or BLMManual Section 9113 concerning roadconstruction standards on projects subject to federal jurisdiction. During the drilling andproduction phase of operations, the road surface and shoulders will be kept in a safe anduseable condition and drainage ditches and culverts will be kept clear and free flowing.

3. LOCATION oF EXISTING WELLs WITHIN A ONE-MILE RADIUS:

See attached TOPO map "C" for the location of wells within a one-mile

Page 27: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 2

4. LOCATION OF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed for production. Facilities will consist of wellhead valves, combo separator-dehy unit with meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines – A 4” gathering line will be buried from the dehy unit to the edge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas. 2. The pipeline will be a permanent feeder line. 3. No off well pad pipeline will be required. The existing pipeline for producing the

CWU 508-25F will be used. .

4. Proposed pipeline will be a 4” OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilities will be required.

All permanent (on site for six months or longer) structures constructed or installed (including pumping units) will be painted a flat, non-reflective, earthtone color to match one of the standard environmental colors, as determined by the Rocky Mountain Five State Interagency

Committee. All facilities will be painted within 6 months of installation. All facilities will be

painted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (Occupational Safety and Health Act) will be excluded.

5. LOCATION AND TYPE OF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E, Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on lease.

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 2

4. LOCATION oF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed forproduction. Facilities will consist of wellhead valves, combo separator-dehy unitwith meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines - A 4" gathering line will be buried from the dehy unit to theedge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas.

2. The pipeline will be a permanent feeder line.

3. No off well pad pipeline will be required. The existing pipeline for producing theCWU 508-25F will be used. .

4. Proposed pipeline will be a 4" OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilitieswill be required.

All permanent (on site for six months or longer) structures constructed or installed (includingpumping units) will be painted a flat, non-reflective, earthtone color to match one of thestandard environmental colors, as determined by the Rocky Mountain Five State InteragencyCommittee. All facilities will be painted within 6 months of installation. AII facilities will bepainted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (OccupationalSafety and Health Act) will be excluded.

5. LOCATION AND TYPE oF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E,Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 2

4. LOCATION oF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed forproduction. Facilities will consist of wellhead valves, combo separator-dehy unitwith meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines -- A 4" gathering line will be buried from the dehy unit to theedge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas.

2. The pipeline will be a permanent feeder line.

3. No off well pad pipeline will be required. The existing pipeline for producing theCWU 508-25F will be used. .

4. Proposed pipeline will be a 4" OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilitieswill be required.

All permanent (on site for six months or longer) structures constructed or installed (includingpumping units) will be painted a flat, non-reflective, earthtone color to match one of thestandard environmental colors, as determined by the Rocky Mountain Five State InteragencyCommittee. All facilities will be painted within 6 months of installation. AII facilities will bepainted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (OccupationalSafety and Health Act) will be excluded.

5. LOCATION AND TYPE oF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E,Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 2

4. LOCATION oF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed forproduction. Facilities will consist of wellhead valves, combo separator-dehy unitwith meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines -- A 4" gathering line will be buried from the dehy unit to theedge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas.

2. The pipeline will be a permanent feeder line.

3. No off well pad pipeline will be required. The existing pipeline for producing theCWU 508-25F will be used. .

4. Proposed pipeline will be a 4" OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilitieswill be required.

All permanent (on site for six months or longer) structures constructed or installed (includingpumping units) will be painted a flat, non-reflective, earthtone color to match one of thestandard environmental colors, as determined by the Rocky Mountain Five State InteragencyCommittee. All facilities will be painted within 6 months of installation. AII facilities will bepainted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (OccupationalSafety and Health Act) will be excluded.

5. LOCATION AND TYPE oF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E,Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 2

4. LOCATION oF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed forproduction. Facilities will consist of wellhead valves, combo separator-dehy unitwith meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines -- A 4" gathering line will be buried from the dehy unit to theedge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas.

2. The pipeline will be a permanent feeder line.

3. No off well pad pipeline will be required. The existing pipeline for producing theCWU 508-25F will be used. .

4. Proposed pipeline will be a 4" OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilitieswill be required.

All permanent (on site for six months or longer) structures constructed or installed (includingpumping units) will be painted a flat, non-reflective, earthtone color to match one of thestandard environmental colors, as determined by the Rocky Mountain Five State InteragencyCommittee. All facilities will be painted within 6 months of installation. AII facilities will bepainted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (OccupationalSafety and Health Act) will be excluded.

5. LOCATION AND TYPE oF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E,Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 2

4. LOCATION oF EXISTING AND/OR PROPOSED PRODUCTION FACILITIES:

A. On Well Pad

1. Production facilities will be set on location if the well is successfully completed forproduction. Facilities will consist of wellhead valves, combo separator-dehy unitwith meter, six (6) to Ten (10) 400-bbl vertical tanks and associated pipe.

2. Gas gathering lines -- A 4" gathering line will be buried from the dehy unit to theedge of the location.

B. Off Well Pad

1. Proposed pipeline will transport natural gas.

2. The pipeline will be a permanent feeder line.

3. No off well pad pipeline will be required. The existing pipeline for producing theCWU 508-25F will be used. .

4. Proposed pipeline will be a 4" OD steel, zap-lok line laid on the surface

5. Proposed pipeline will be laid on surface.

6. Pipeline will be coupled using the Zap lock method. No additional off-pad facilitieswill be required.

All permanent (on site for six months or longer) structures constructed or installed (includingpumping units) will be painted a flat, non-reflective, earthtone color to match one of thestandard environmental colors, as determined by the Rocky Mountain Five State InteragencyCommittee. All facilities will be painted within 6 months of installation. AII facilities will bepainted with Carlsbad Canyon. Facilities required to comply with O.S.H.A. (OccupationalSafety and Health Act) will be excluded.

5. LOCATION AND TYPE oF WATER SUPPLY:

A. Water supply will be Bonanza Power Plant water source in Sec 26, T8S, R23E,Uintah County, UT (State Water Right # 49-225(A31368)).

B. Water will be hauled by a licensed trucking company.

C. No water well will be drilled on

Page 28: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 3

6. SOURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soil accumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODS OF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit. 2. A portable toilet will be provided for human waste during the drilling and

completion of the well. Disposal will be at the Vernal sewage disposal plant. 3. Burning will not be allowed. Trash and other waste material will be contained in a

wire mesh cage and disposed of at the Uintah County Landfill. 4. Produced wastewater will be confined to a storage tank for a period not to exceed

90 days after initial production. After the 90 day period, the produced water will be contained in a tank on location and then disposed of at one of the following locations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWD CWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or Coyote Evaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, or Hoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources, Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & Stagecoach Unit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans and

absorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed of by either evaporating in the reserve pit, through natural or artificial methods, or removed and disposed of at an authorized disposal site. Introduction of well bore hydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at the time of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loop system will be installed in a manner that prevents leaks, breaks, or discharge. Drilll cutting will be contained in an area approximately 50’ x 100’. The surface drill cuttings pile will be bermed and lined with bentonite. Drill cuttings will be dried and spread on the location and access road. More stringent protective requirements may be deemed necessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g) containing current Material Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substances which are used during the course of construction, drilling, completion, and production operations for this project. Hazardous materials (substances) which may be found at

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 3

6. SoURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soilaccumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODs oF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit.

2. A portable toiletwill be provided for human waste during the drilling andcompletion of the well. Disposal will be at the Vernal sewage disposal plant.

3. Burning will not be allowed. Trash and other waste material will be contained in awire mesh cage and disposed of at the Uintah County Landfill.

4. Produced wastewater will be confined to a storage tank for a period not to exceed90 days after initial production. After the 90 day period, the produced water will becontained in a tank on location and then disposed of at one of the followinglocations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWDCWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or CoyoteEvaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, orHoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources,Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & StagecoachUnit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans andabsorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed ofby either evaporating in the reserve pit, through natural or artificial methods, orremoved and disposed of at an authorized disposal site. Introduction of well borehydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at thetime of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loopsystem will be installed in a manner that prevents leaks, breaks, or discharge. Drilllcutting will be contained in an area approximately 50' x 100'. The surface drill cuttingspile will be bermed and lined with bentonite. Drillcuttings will be dried and spread onthe location and access road. More stringent protective requirements may be deemednecessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g)containing currentMaterial Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substanceswhich are used during the course of construction, drilling, completion, and productionoperations for this project. Hazardous materials (substances) which may be found

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 3

6. SoURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soilaccumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODs oF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit.

2. A portable toiletwill be provided for human waste during the drilling andcompletion of the well. Disposal will be at the Vernal sewage disposal plant.

3. Burning will not be allowed. Trash and other waste material will be contained in awire mesh cage and disposed of at the Uintah County Landfill.

4. Produced wastewater will be confined to a storage tank for a period not to exceed90 days after initial production. After the 90 day period, the produced water will becontained in a tank on location and then disposed of at one of the followinglocations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWDCWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or CoyoteEvaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, orHoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources,Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & StagecoachUnit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans andabsorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed ofby either evaporating in the reserve pit, through natural or artificial methods, orremoved and disposed of at an authorized disposal site. Introduction of well borehydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at thetime of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loopsystem will be installed in a manner that prevents leaks, breaks, or discharge. Drilllcutting will be contained in an area approximately 50' x 100'. The surface drill cuttingspile will be bermed and lined with bentonite. Drillcuttings will be dried and spread onthe location and access road. More stringent protective requirements may be deemednecessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g)containing currentMaterial Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substanceswhich are used during the course of construction, drilling, completion, and productionoperations for this project. Hazardous materials (substances) which may be found

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 3

6. SoURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soilaccumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODs oF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit.

2. A portable toiletwill be provided for human waste during the drilling andcompletion of the well. Disposal will be at the Vernal sewage disposal plant.

3. Burning will not be allowed. Trash and other waste material will be contained in awire mesh cage and disposed of at the Uintah County Landfill.

4. Produced wastewater will be confined to a storage tank for a period not to exceed90 days after initial production. After the 90 day period, the produced water will becontained in a tank on location and then disposed of at one of the followinglocations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWDCWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or CoyoteEvaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, orHoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources,Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & StagecoachUnit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans andabsorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed ofby either evaporating in the reserve pit, through natural or artificial methods, orremoved and disposed of at an authorized disposal site. Introduction of well borehydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at thetime of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loopsystem will be installed in a manner that prevents leaks, breaks, or discharge. Drilllcutting will be contained in an area approximately 50' x 100'. The surface drill cuttingspile will be bermed and lined with bentonite. Drillcuttings will be dried and spread onthe location and access road. More stringent protective requirements may be deemednecessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g)containing currentMaterial Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substanceswhich are used during the course of construction, drilling, completion, and productionoperations for this project. Hazardous materials (substances) which may be found

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 3

6. SoURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soilaccumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODs oF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit.

2. A portable toiletwill be provided for human waste during the drilling andcompletion of the well. Disposal will be at the Vernal sewage disposal plant.

3. Burning will not be allowed. Trash and other waste material will be contained in awire mesh cage and disposed of at the Uintah County Landfill.

4. Produced wastewater will be confined to a storage tank for a period not to exceed90 days after initial production. After the 90 day period, the produced water will becontained in a tank on location and then disposed of at one of the followinglocations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWDCWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or CoyoteEvaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, orHoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources,Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & StagecoachUnit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans andabsorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed ofby either evaporating in the reserve pit, through natural or artificial methods, orremoved and disposed of at an authorized disposal site. Introduction of well borehydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at thetime of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loopsystem will be installed in a manner that prevents leaks, breaks, or discharge. Drilllcutting will be contained in an area approximately 50' x 100'. The surface drill cuttingspile will be bermed and lined with bentonite. Drillcuttings will be dried and spread onthe location and access road. More stringent protective requirements may be deemednecessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g)containing currentMaterial Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substanceswhich are used during the course of construction, drilling, completion, and productionoperations for this project. Hazardous materials (substances) which may be found

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 3

6. SoURCE OF CONSTRUCTION MATERIALS:

A. All construction material for this pipeline will be of native borrow and soilaccumulated during the construction of the location.

B. No mineral materials will be required.

7. METHODs oF HANDLING WASTE DISPOSAL:

A. METHODS AND LOCATION

1. Cuttings will be confined in the reserve pit.

2. A portable toiletwill be provided for human waste during the drilling andcompletion of the well. Disposal will be at the Vernal sewage disposal plant.

3. Burning will not be allowed. Trash and other waste material will be contained in awire mesh cage and disposed of at the Uintah County Landfill.

4. Produced wastewater will be confined to a storage tank for a period not to exceed90 days after initial production. After the 90 day period, the produced water will becontained in a tank on location and then disposed of at one of the followinglocations: Natural Buttes Unit 21-20B SWD, Ace Disposal, CWU 550-30N SWDCWU 2-29 SWD, Red Wash Evaporation Ponds 1, 2, 3, 4, 5, 6, or 7, or CoyoteEvaporation Ponds 1, 2, 3, or 4, or White River Evaporation Ponds 1, or 2, orHoss SWD Facility, right-of-way UTU 86010, UTU 897093 or EOG Resources,Inc. drilling operations (Chapita Wells Unit, Natural Buttes Unit & StagecoachUnit).

5. All chemicals will be disposed of at an authorized disposal site. Drip pans andabsorbent pads will be used on the drilling rig to avoid leakage of oil to the pit.

B. Water from drilling fluids and recovered during testing operations will be disposed ofby either evaporating in the reserve pit, through natural or artificial methods, orremoved and disposed of at an authorized disposal site. Introduction of well borehydrocarbons to the reserve pit will be avoided by flaring them off in the flare pit at thetime of recovery.

The referenced well will be drilled utilizing a closed loop system. The closed loopsystem will be installed in a manner that prevents leaks, breaks, or discharge. Drilllcutting will be contained in an area approximately 50' x 100'. The surface drill cuttingspile will be bermed and lined with bentonite. Drillcuttings will be dried and spread onthe location and access road. More stringent protective requirements may be deemednecessary by the A.O.

EOG Resources, Inc. maintains a file, per 29 CFR 1910.1200 (g)containing currentMaterial Safety Data Sheets (MSDS) for all chemicals, compounds, and/or substanceswhich are used during the course of construction, drilling, completion, and productionoperations for this project. Hazardous materials (substances) which may be found

Page 29: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalation hazards, fuels (flammable and/or combustible), materials that may be necessary for well completion/ stimulation activities such as flammable or combustible substances and acids/gels (corrosives). The opportunity for Superfund Amendments and Reauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the site is generally limited to proprietary treating chemicals. All hazardous and EHS and commercial preparations will be handled in an appropriate manner to minimize the potential for leaks or spills to the environment. No chemicals subject to reporting under SARA Title III (hazardous materials) in an amount greater than 10,000 pounds will be used, produced, stored, transported, or disposed of annually in association with the drilling, testing, or completion of the well. Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in threshold planning quantities, will not be used, produced, stored, transported, or disposed of in association with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and cross sections.

B. Refer to attached well site plat for rig layout and soil material stockpile location as

approved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road. The stockpiled location topsoil will be stored in a location providing easy access for interim reclamation and protection of the topsoil. Upon completion of construction, the stockpiled topsoil from the location will be broadcast seeded with the approved seed mixture from this location. Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10. PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location) Immediately upon well completion, the location and surrounding area will be cleared of all unused tubing, equipment, debris, materials, trash, and junk not required for production.

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalationhazards, fuels (flammable and/or combustible), materials that may be necessary forwell completion/ stimulation activities such as flammable or combustible substancesand acids/gels (corrosives). The opportunity for Superfund Amendments andReauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the siteis generally limited to proprietary treating chemicals. All hazardous and EHS andcommercial preparations will be handled in an appropriate manner to minimize thepotential for leaks or spills to the environment.

No chemicals subject to reporting under SARA Title Ill (hazardous materials) in anamount greater than 10,000 pounds will be used, produced, stored, transported, ordisposed of annually in association with the drilling, testing, or completion of the well.Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in thresholdplanning quantities, will not be used, produced, stored, transported, or disposed of inassociation with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and crosssections.

B. Refer to attached well site plat for rig layout and soil material stockpile location asapproved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road.

The stockpiled location topsoil will be stored in a location providing easy access for interimreclamation and protection of the topsoil. Upon completion of construction, the stockpiledtopsoil from the location will be broadcast seeded with the approved seed mixture from thislocation.

Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10.PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location)

Immediately upon well completion, the location and surrounding area will be clearedof all unused tubing, equipment, debris, materials, trash, and junk not required for

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalationhazards, fuels (flammable and/or combustible), materials that may be necessary forwell completion/ stimulation activities such as flammable or combustible substancesand acids/gels (corrosives). The opportunity for Superfund Amendments andReauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the siteis generally limited to proprietary treating chemicals. All hazardous and EHS andcommercial preparations will be handled in an appropriate manner to minimize thepotential for leaks or spills to the environment.

No chemicals subject to reporting under SARA Title Ill (hazardous materials) in anamount greater than 10,000 pounds will be used, produced, stored, transported, ordisposed of annually in association with the drilling, testing, or completion of the well.Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in thresholdplanning quantities, will not be used, produced, stored, transported, or disposed of inassociation with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and crosssections.

B. Refer to attached well site plat for rig layout and soil material stockpile location asapproved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road.

The stockpiled location topsoil will be stored in a location providing easy access for interimreclamation and protection of the topsoil. Upon completion of construction, the stockpiledtopsoil from the location will be broadcast seeded with the approved seed mixture from thislocation.

Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10.PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location)

Immediately upon well completion, the location and surrounding area will be clearedof all unused tubing, equipment, debris, materials, trash, and junk not required for

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalationhazards, fuels (flammable and/or combustible), materials that may be necessary forwell completion/ stimulation activities such as flammable or combustible substancesand acids/gels (corrosives). The opportunity for Superfund Amendments andReauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the siteis generally limited to proprietary treating chemicals. All hazardous and EHS andcommercial preparations will be handled in an appropriate manner to minimize thepotential for leaks or spills to the environment.

No chemicals subject to reporting under SARA Title Ill (hazardous materials) in anamount greater than 10,000 pounds will be used, produced, stored, transported, ordisposed of annually in association with the drilling, testing, or completion of the well.Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in thresholdplanning quantities, will not be used, produced, stored, transported, or disposed of inassociation with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and crosssections.

B. Refer to attached well site plat for rig layout and soil material stockpile location asapproved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road.

The stockpiled location topsoil will be stored in a location providing easy access for interimreclamation and protection of the topsoil. Upon completion of construction, the stockpiledtopsoil from the location will be broadcast seeded with the approved seed mixture from thislocation.

Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10.PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location)

Immediately upon well completion, the location and surrounding area will be clearedof all unused tubing, equipment, debris, materials, trash, and junk not required for

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalationhazards, fuels (flammable and/or combustible), materials that may be necessary forwell completion/ stimulation activities such as flammable or combustible substancesand acids/gels (corrosives). The opportunity for Superfund Amendments andReauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the siteis generally limited to proprietary treating chemicals. All hazardous and EHS andcommercial preparations will be handled in an appropriate manner to minimize thepotential for leaks or spills to the environment.

No chemicals subject to reporting under SARA Title Ill (hazardous materials) in anamount greater than 10,000 pounds will be used, produced, stored, transported, ordisposed of annually in association with the drilling, testing, or completion of the well.Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in thresholdplanning quantities, will not be used, produced, stored, transported, or disposed of inassociation with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and crosssections.

B. Refer to attached well site plat for rig layout and soil material stockpile location asapproved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road.

The stockpiled location topsoil will be stored in a location providing easy access for interimreclamation and protection of the topsoil. Upon completion of construction, the stockpiledtopsoil from the location will be broadcast seeded with the approved seed mixture from thislocation.

Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10.PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location)

Immediately upon well completion, the location and surrounding area will be clearedof all unused tubing, equipment, debris, materials, trash, and junk not required for

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 4

the site may include drilling mud and cementing products which are primarily inhalationhazards, fuels (flammable and/or combustible), materials that may be necessary forwell completion/ stimulation activities such as flammable or combustible substancesand acids/gels (corrosives). The opportunity for Superfund Amendments andReauthorization Act (SARA) listed Extremely Hazardous Substances (EHS) at the siteis generally limited to proprietary treating chemicals. All hazardous and EHS andcommercial preparations will be handled in an appropriate manner to minimize thepotential for leaks or spills to the environment.

No chemicals subject to reporting under SARA Title Ill (hazardous materials) in anamount greater than 10,000 pounds will be used, produced, stored, transported, ordisposed of annually in association with the drilling, testing, or completion of the well.Furthermore, extremely hazardous substances, as defined in 40 CFR 355, in thresholdplanning quantities, will not be used, produced, stored, transported, or disposed of inassociation with the drilling, testing or completion of the well.

8. ANCILLARY FACILITIES:

None anticipated.

9. WELL SITE LAYOUT:

A. Refer to attached well site plat for related topography cuts and fills and crosssections.

B. Refer to attached well site plat for rig layout and soil material stockpile location asapproved on On-site.

C. Refer to attached well site plat for rig orientation, parking areas, and access road.

The stockpiled location topsoil will be stored in a location providing easy access for interimreclamation and protection of the topsoil. Upon completion of construction, the stockpiledtopsoil from the location will be broadcast seeded with the approved seed mixture from thislocation.

Access to the well pad will be from the East.

The corners of the well pad will be rounded off as needed to minimize excavation.

10.PLANS FOR RECLAMATION OF THE SURFACE:

A. Interim Reclamation (Producing Location)

Immediately upon well completion, the location and surrounding area will be clearedof all unused tubing, equipment, debris, materials, trash, and junk not required for

Page 30: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed in accordance with CFR 3162.7-1. If a plastic nylon reinforced liner is used, it shall be torn and perforated before backfilling of the reserve pit. The portion of the location not needed for production facilities/operations will be reclaimed – See attached Figure #3. The stockpiled topsoil will then be spread over the pit area and broadcast seeded with the prescribed seed mixture for this location as authorized within EOG’s reclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit a subsequent report of abandonment and the BLM will attach the appropriate final reclamation conditions of approval.

11. SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12. OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with this project that they are subject to prosecution for knowingly disturbing historic or archaeological sites, or for collecting artifacts. If historic or archaeological materials are uncovered during construction, the operator will immediately stop work that might further disturb such materials, and contact the Authorized Officer. Within five working days the Authorized Officer will inform the operator as to:

Whether the materials appear eligible for the National Register of Historic Places;

The mitigation measures the operator will likely have to undertake before the site can be used.

A time frame for the Authorized Officer to complete an expedited review under 36 CFR 800.11 to confirm, through the State Historic Preservation Officer, that the findings of the Authorized Officer are correct and that mitigation is appropriate.

If the operator wished, at any time, to relocate activities to avoid the expense of mitigation and/or the delays associated with this process, the Authorized Officer will assume responsibility for whatever recordation and stabilization of the exposed materials that may be required. Otherwise, the operator will be responsible for

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed inaccordance with CFR 3162.7-1.

If a plastic nylon reinforced liner is used, it shall be torn and perforated beforebackfilling of the reserve pit.

The portion of the location not needed for production facilitiesloperations will bereclaimed - See attached Figure #3.

The stockpiled topsoil will then be spread over the pit area and broadcast seededwith the prescribed seed mixture for this location as authorized within EOG'sreclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit asubsequent report of abandonment and the BLMwill attach the appropriate finalreclamation conditions of approval.

11.SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12.OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with thisproject that they are subject to prosecution for knowingly disturbing historic orarchaeological sites, or for collecting artifacts. If historic or archaeological materialsare uncovered during construction, the operator will immediately stop work that mightfurther disturb such materials, and contact the Authorized Officer. Within five workingdays the Authorized Officer will inform the operator as to:

• Whether the materials appear eligible for the National Register of HistoricPlaces;

• The mitigation measures the operator will likely have to undertake before thesite can be used.

• A time frame for the Authorized Officer to complete an expedited review under36 CFR 800.11 to confirm, through the State Historic Preservation Officer,that the findings of the Authorized Officer are correct and that mitigation isappropriate.

If the operator wished, at any time, to relocate activities to avoid the expense ofmitigation and/or the delays associated with this process, the Authorized Officer willassume responsibility for whatever recordation and stabilization of the exposedmaterials that may be required. Otherwise, the operator will be responsible

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed inaccordance with CFR 3162.7-1.

If a plastic nylon reinforced liner is used, it shall be torn and perforated beforebackfilling of the reserve pit.

The portion of the location not needed for production facilitiesloperations will bereclaimed - See attached Figure #3.

The stockpiled topsoil will then be spread over the pit area and broadcast seededwith the prescribed seed mixture for this location as authorized within EOG'sreclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit asubsequent report of abandonment and the BLMwill attach the appropriate finalreclamation conditions of approval.

11.SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12.OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with thisproject that they are subject to prosecution for knowingly disturbing historic orarchaeological sites, or for collecting artifacts. If historic or archaeological materialsare uncovered during construction, the operator will immediately stop work that mightfurther disturb such materials, and contact the Authorized Officer. Within five workingdays the Authorized Officer will inform the operator as to:

• Whether the materials appear eligible for the National Register of HistoricPlaces;

• The mitigation measures the operator will likely have to undertake before thesite can be used.

• A time frame for the Authorized Officer to complete an expedited review under36 CFR 800.11 to confirm, through the State Historic Preservation Officer,that the findings of the Authorized Officer are correct and that mitigation isappropriate.

If the operator wished, at any time, to relocate activities to avoid the expense ofmitigation and/or the delays associated with this process, the Authorized Officer willassume responsibility for whatever recordation and stabilization of the exposedmaterials that may be required. Otherwise, the operator will be responsible

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed inaccordance with CFR 3162.7-1.

If a plastic nylon reinforced liner is used, it shall be torn and perforated beforebackfilling of the reserve pit.

The portion of the location not needed for production facilitiesloperations will bereclaimed - See attached Figure #3.

The stockpiled topsoil will then be spread over the pit area and broadcast seededwith the prescribed seed mixture for this location as authorized within EOG'sreclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit asubsequent report of abandonment and the BLMwill attach the appropriate finalreclamation conditions of approval.

11.SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12.OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with thisproject that they are subject to prosecution for knowingly disturbing historic orarchaeological sites, or for collecting artifacts. If historic or archaeological materialsare uncovered during construction, the operator will immediately stop work that mightfurther disturb such materials, and contact the Authorized Officer. Within five workingdays the Authorized Officer will inform the operator as to:

• Whether the materials appear eligible for the National Register of HistoricPlaces;

• The mitigation measures the operator will likely have to undertake before thesite can be used.

• A time frame for the Authorized Officer to complete an expedited review under36 CFR 800.11 to confirm, through the State Historic Preservation Officer,that the findings of the Authorized Officer are correct and that mitigation isappropriate.

If the operator wished, at any time, to relocate activities to avoid the expense ofmitigation and/or the delays associated with this process, the Authorized Officer willassume responsibility for whatever recordation and stabilization of the exposedmaterials that may be required. Otherwise, the operator will be responsible

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed inaccordance with CFR 3162.7-1.

If a plastic nylon reinforced liner is used, it shall be torn and perforated beforebackfilling of the reserve pit.

The portion of the location not needed for production facilitiesloperations will bereclaimed - See attached Figure #3.

The stockpiled topsoil will then be spread over the pit area and broadcast seededwith the prescribed seed mixture for this location as authorized within EOG'sreclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit asubsequent report of abandonment and the BLMwill attach the appropriate finalreclamation conditions of approval.

11.SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12.OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with thisproject that they are subject to prosecution for knowingly disturbing historic orarchaeological sites, or for collecting artifacts. If historic or archaeological materialsare uncovered during construction, the operator will immediately stop work that mightfurther disturb such materials, and contact the Authorized Officer. Within five workingdays the Authorized Officer will inform the operator as to:

• Whether the materials appear eligible for the National Register of HistoricPlaces;

• The mitigation measures the operator will likely have to undertake before thesite can be used.

• A time frame for the Authorized Officer to complete an expedited review under36 CFR 800.11 to confirm, through the State Historic Preservation Officer,that the findings of the Authorized Officer are correct and that mitigation isappropriate.

If the operator wished, at any time, to relocate activities to avoid the expense ofmitigation and/or the delays associated with this process, the Authorized Officer willassume responsibility for whatever recordation and stabilization of the exposedmaterials that may be required. Otherwise, the operator will be responsible

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 5

Immediately upon well completion, any hydrocarbons on the pit shall be removed inaccordance with CFR 3162.7-1.

If a plastic nylon reinforced liner is used, it shall be torn and perforated beforebackfilling of the reserve pit.

The portion of the location not needed for production facilitiesloperations will bereclaimed - See attached Figure #3.

The stockpiled topsoil will then be spread over the pit area and broadcast seededwith the prescribed seed mixture for this location as authorized within EOG'sreclamation plan approved September 2009.

B. Dry Hole/Abandoned Location

At such time as the well is plugged and abandoned, the operator will submit asubsequent report of abandonment and the BLMwill attach the appropriate finalreclamation conditions of approval.

11.SURFACE OWNERSHIP:

Surface ownership of the proposed well site, access road, and pipeline route is as follows:

Bureau of Land Management

12.OTHER INFORMATION:

A. EOG Resources, Inc. will inform all persons in the area who are associated with thisproject that they are subject to prosecution for knowingly disturbing historic orarchaeological sites, or for collecting artifacts. If historic or archaeological materialsare uncovered during construction, the operator will immediately stop work that mightfurther disturb such materials, and contact the Authorized Officer. Within five workingdays the Authorized Officer will inform the operator as to:

• Whether the materials appear eligible for the National Register of HistoricPlaces;

• The mitigation measures the operator will likely have to undertake before thesite can be used.

• A time frame for the Authorized Officer to complete an expedited review under36 CFR 800.11 to confirm, through the State Historic Preservation Officer,that the findings of the Authorized Officer are correct and that mitigation isappropriate.

If the operator wished, at any time, to relocate activities to avoid the expense ofmitigation and/or the delays associated with this process, the Authorized Officer willassume responsibility for whatever recordation and stabilization of the exposedmaterials that may be required. Otherwise, the operator will be responsible

Page 31: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and procedural guidelines for the conduct of mitigation. Upon verification from the Authorized Officer that required mitigation has been completed, the operator will then be allowed to resume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way for

roads, pipelines, well sites, or other applicable facilities. Prior to the application of herbicides or other pesticides or possible hazardous chemicals A Pesticide Use proposal shall be submitted for BLM approval.

C. Drilling rigs and/or equipment used during drilling operations on this well site will not

be stacked or stored on BLM lands after the conclusion of drilling operations or at any other time without BLM authorization. However, if BLM authorization is obtained, it is only a temporary measure to allow time to make arrangements for permanent storage on commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior to

commencement of completion operations. Completion operations will be conducted utilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance is made with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Plan of Operations, and any applicable Notice of Lessees. The operator is fully responsible for the actions of its subcontractors. A complete copy of the approved “Application for Permit to Drill” will be furnished to the field representative(s) to ensure compliance and shall be on location during all construction and drilling operations. Construction activity will not be conducted using frozen or saturated soils material or during periods when watershed damage is likely to occur. If the existing access road, proposed access road, and proposed pad are dry during construction, drilling, and completion activities, water will be applied to help facilitate compaction during construction and to minimize soil loss as a result of wind erosion. A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted by Montgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. A special status plant and wildlife species reports was conducted and submitted by Grasslands Consulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

None

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and proceduralguidelines for the conduct of mitigation. Upon verification from the Authorized Officerthat required mitigation has been completed, the operator will then be allowed toresume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way forroads, pipelines, well sites, or other applicable facilities. Prior to the application ofherbicides or other pesticides or possible hazardous chemicals A Pesticide Useproposal shall be submitted for BLMapproval.

C. Drillingrigs and/or equipment used during drilling operations on this well site will notbe stacked or stored on BLMlands after the conclusion of drilling operations or at anyother time without BLMauthorization. However, if BLMauthorization is obtained, it isonly a temporary measure to allow time to make arrangements for permanent storageon commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior tocommencement of completion operations. Completion operations will be conductedutilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Planof Operations, and any applicable Notice of Lessees. The operator is fully responsible forthe actions of its subcontractors. A complete copy of the approved "Application for Permit toDrill"will be furnished to the field representative(s) to ensure compliance and shall be onlocation during all construction and drilling operations.

Construction activity will not be conducted using frozen or saturated soils material or duringperiods when watershed damage is likely to occur.

If the existing access road, proposed access road, and proposed pad are dry duringconstruction, drilling, and completion activities, water will be applied to help facilitatecompaction during construction and to minimize soil loss as a result of wind erosion.

A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted byMontgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. Aspecial status plant and wildlife species reports was conducted and submitted by GrasslandsConsulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and proceduralguidelines for the conduct of mitigation. Upon verification from the Authorized Officerthat required mitigation has been completed, the operator will then be allowed toresume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way forroads, pipelines, well sites, or other applicable facilities. Prior to the application ofherbicides or other pesticides or possible hazardous chemicals A Pesticide Useproposal shall be submitted for BLMapproval.

C. Drillingrigs and/or equipment used during drilling operations on this well site will notbe stacked or stored on BLMlands after the conclusion of drilling operations or at anyother time without BLMauthorization. However, if BLMauthorization is obtained, it isonly a temporary measure to allow time to make arrangements for permanent storageon commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior tocommencement of completion operations. Completion operations will be conductedutilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Planof Operations, and any applicable Notice of Lessees. The operator is fully responsible forthe actions of its subcontractors. A complete copy of the approved "Application for Permit toDrill"will be furnished to the field representative(s) to ensure compliance and shall be onlocation during all construction and drilling operations.

Construction activity will not be conducted using frozen or saturated soils material or duringperiods when watershed damage is likely to occur.

If the existing access road, proposed access road, and proposed pad are dry duringconstruction, drilling, and completion activities, water will be applied to help facilitatecompaction during construction and to minimize soil loss as a result of wind erosion.

A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted byMontgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. Aspecial status plant and wildlife species reports was conducted and submitted by GrasslandsConsulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and proceduralguidelines for the conduct of mitigation. Upon verification from the Authorized Officerthat required mitigation has been completed, the operator will then be allowed toresume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way forroads, pipelines, well sites, or other applicable facilities. Prior to the application ofherbicides or other pesticides or possible hazardous chemicals A Pesticide Useproposal shall be submitted for BLMapproval.

C. Drillingrigs and/or equipment used during drilling operations on this well site will notbe stacked or stored on BLMlands after the conclusion of drilling operations or at anyother time without BLMauthorization. However, if BLMauthorization is obtained, it isonly a temporary measure to allow time to make arrangements for permanent storageon commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior tocommencement of completion operations. Completion operations will be conductedutilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Planof Operations, and any applicable Notice of Lessees. The operator is fully responsible forthe actions of its subcontractors. A complete copy of the approved "Application for Permit toDrill"will be furnished to the field representative(s) to ensure compliance and shall be onlocation during all construction and drilling operations.

Construction activity will not be conducted using frozen or saturated soils material or duringperiods when watershed damage is likely to occur.

If the existing access road, proposed access road, and proposed pad are dry duringconstruction, drilling, and completion activities, water will be applied to help facilitatecompaction during construction and to minimize soil loss as a result of wind erosion.

A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted byMontgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. Aspecial status plant and wildlife species reports was conducted and submitted by GrasslandsConsulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and proceduralguidelines for the conduct of mitigation. Upon verification from the Authorized Officerthat required mitigation has been completed, the operator will then be allowed toresume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way forroads, pipelines, well sites, or other applicable facilities. Prior to the application ofherbicides or other pesticides or possible hazardous chemicals A Pesticide Useproposal shall be submitted for BLMapproval.

C. Drillingrigs and/or equipment used during drilling operations on this well site will notbe stacked or stored on BLMlands after the conclusion of drilling operations or at anyother time without BLMauthorization. However, if BLMauthorization is obtained, it isonly a temporary measure to allow time to make arrangements for permanent storageon commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior tocommencement of completion operations. Completion operations will be conductedutilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Planof Operations, and any applicable Notice of Lessees. The operator is fully responsible forthe actions of its subcontractors. A complete copy of the approved "Application for Permit toDrill"will be furnished to the field representative(s) to ensure compliance and shall be onlocation during all construction and drilling operations.

Construction activity will not be conducted using frozen or saturated soils material or duringperiods when watershed damage is likely to occur.

If the existing access road, proposed access road, and proposed pad are dry duringconstruction, drilling, and completion activities, water will be applied to help facilitatecompaction during construction and to minimize soil loss as a result of wind erosion.

A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted byMontgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. Aspecial status plant and wildlife species reports was conducted and submitted by GrasslandsConsulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 6

mitigation costs. The Authorized Officer will provide technical and proceduralguidelines for the conduct of mitigation. Upon verification from the Authorized Officerthat required mitigation has been completed, the operator will then be allowed toresume construction.

B. As operator, EOG Resources, Inc. will control noxious weeds along rights-of-way forroads, pipelines, well sites, or other applicable facilities. Prior to the application ofherbicides or other pesticides or possible hazardous chemicals A Pesticide Useproposal shall be submitted for BLMapproval.

C. Drillingrigs and/or equipment used during drilling operations on this well site will notbe stacked or stored on BLMlands after the conclusion of drilling operations or at anyother time without BLMauthorization. However, if BLMauthorization is obtained, it isonly a temporary measure to allow time to make arrangements for permanent storageon commercial facilities.

D. The drilling rig and ancillary equipment will be removed from the location prior tocommencement of completion operations. Completion operations will be conductedutilizing a completion/workover rig.

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved Planof Operations, and any applicable Notice of Lessees. The operator is fully responsible forthe actions of its subcontractors. A complete copy of the approved "Application for Permit toDrill"will be furnished to the field representative(s) to ensure compliance and shall be onlocation during all construction and drilling operations.

Construction activity will not be conducted using frozen or saturated soils material or duringperiods when watershed damage is likely to occur.

If the existing access road, proposed access road, and proposed pad are dry duringconstruction, drilling, and completion activities, water will be applied to help facilitatecompaction during construction and to minimize soil loss as a result of wind erosion.

A block cultural resources survey for Sec, 25, T9S, R22E was conducted and submitted byMontgomery Archaeological Consultants, MOAC report # 06-615, on April 14, 2007. Aspecial status plant and wildlife species reports was conducted and submitted by GrasslandsConsulting, Inc. on April 7, 2010.

Additional Surface Stipulations:

Page 32: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 7

LESSEE OR OPERATOR’S REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENT Nanette Lupcho EOG Resources, Inc. 1060 East Highway 40 Vernal, UT 84078 (435) 781-9111 All lease and/or unit operations will be conducted in such a manner that full compliance is made with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved plan of operations, and any applicable Notice to Lessees. The operator is fully responsible for the actions of his subcontractors. A copy of these conditions will be furnished to the field representative to insure compliance. The operator or his/her contractor shall contact the BLM office at (435) 781-4400 forty-eight (48) hours prior to construction activities.

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 7

LESSEE OR OPERATOR's REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENTNanette LupchoEOG Resources, Inc.1060 East Highway 40Vernal, UT 84078(435) 781-9111

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved planof operations, and any applicable Notice to Lessees. The operator is fully responsible for theactions of his subcontractors. A copy of these conditions will be furnished to the fieldrepresentative to insure compliance.

The operator or his/her contractor shall contact the BLMoffice at (435) 781-4400 forty-eight(48) hours prior to construction

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 7

LESSEE OR OPERATOR's REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENTNanette LupchoEOG Resources, Inc.1060 East Highway 40Vernal, UT 84078(435) 781-9111

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved planof operations, and any applicable Notice to Lessees. The operator is fully responsible for theactions of his subcontractors. A copy of these conditions will be furnished to the fieldrepresentative to insure compliance.

The operator or his/her contractor shall contact the BLMoffice at (435) 781-4400 forty-eight(48) hours prior to construction

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 7

LESSEE OR OPERATOR's REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENTNanette LupchoEOG Resources, Inc.1060 East Highway 40Vernal, UT 84078(435) 781-9111

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved planof operations, and any applicable Notice to Lessees. The operator is fully responsible for theactions of his subcontractors. A copy of these conditions will be furnished to the fieldrepresentative to insure compliance.

The operator or his/her contractor shall contact the BLMoffice at (435) 781-4400 forty-eight(48) hours prior to construction

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 7

LESSEE OR OPERATOR's REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENTNanette LupchoEOG Resources, Inc.1060 East Highway 40Vernal, UT 84078(435) 781-9111

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved planof operations, and any applicable Notice to Lessees. The operator is fully responsible for theactions of his subcontractors. A copy of these conditions will be furnished to the fieldrepresentative to insure compliance.

The operator or his/her contractor shall contact the BLMoffice at (435) 781-4400 forty-eight(48) hours prior to construction

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 7

LESSEE OR OPERATOR's REPRESENTATIVE AND CERTIFICATION:

PERMITTING AGENTNanette LupchoEOG Resources, Inc.1060 East Highway 40Vernal, UT 84078(435) 781-9111

All lease and/or unit operations will be conducted in such a manner that full compliance ismade with all applicable laws, regulations, Onshore Oil and Gas Orders, the approved planof operations, and any applicable Notice to Lessees. The operator is fully responsible for theactions of his subcontractors. A copy of these conditions will be furnished to the fieldrepresentative to insure compliance.

The operator or his/her contractor shall contact the BLMoffice at (435) 781-4400 forty-eight(48) hours prior to construction

Page 33: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D

Surface Use Plan Page 8

CERTIFICATION: I hereby certify that I, or persons under my direct supervision, have inspected the proposed drill site and access route; that I am familiar with the conditions which currently exist; that the statements made in this plan are, to the best of my knowledge, true and correct; and that the work associated with the operations proposed herein will be performed by EOG Resources, Inc. and its contractors and subcontractors in conformity with this plan and the terms and conditions under which it is approved. This statement is subject to the provisions of 18 U.S.C. 1001 for the filing of a false statement. Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, of Section 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsible under the terms and conditions of the lease for the operations conducted upon the leased lands. Bond Coverage is under Bond # NM 2308. May 18, 2010 Date Nanette Lupcho, Regulatory Assistant

'APIWellNo:43047511750000''APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 8

CERTIFICATION:

I hereby certify that I, or persons under my direct supervision, have inspected the proposeddrill site and access route; that I am familiar with the conditions which currently exist; that thestatements made in this plan are, to the best of my knowledge, true and correct; and that thework associated with the operations proposed herein will be performed by EOG Resources,Inc. and its contractors and subcontractors in conformity with this plan and the terms andconditions under which it is approved. This statement is subject to the provisions of 18U.S.C. 1001 for the filing of a false statement.

Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, ofSection 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsibleunder the terms and conditions of the lease for the operations conducted upon the leasedlands. Bond Coverage is under Bond # NM 2308.

May 18, 2010Date Nanette Lupcho, Regulatory

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 8

CERTIFICATION:

I hereby certify that I, or persons under my direct supervision, have inspected the proposeddrill site and access route; that I am familiar with the conditions which currently exist; that thestatements made in this plan are, to the best of my knowledge, true and correct; and that thework associated with the operations proposed herein will be performed by EOG Resources,Inc. and its contractors and subcontractors in conformity with this plan and the terms andconditions under which it is approved. This statement is subject to the provisions of 18U.S.C. 1001 for the filing of a false statement.

Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, ofSection 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsibleunder the terms and conditions of the lease for the operations conducted upon the leasedlands. Bond Coverage is under Bond # NM 2308.

May 18, 2010Date Nanette Lupcho, Regulatory

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 8

CERTIFICATION:

I hereby certify that I, or persons under my direct supervision, have inspected the proposeddrill site and access route; that I am familiar with the conditions which currently exist; that thestatements made in this plan are, to the best of my knowledge, true and correct; and that thework associated with the operations proposed herein will be performed by EOG Resources,Inc. and its contractors and subcontractors in conformity with this plan and the terms andconditions under which it is approved. This statement is subject to the provisions of 18U.S.C. 1001 for the filing of a false statement.

Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, ofSection 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsibleunder the terms and conditions of the lease for the operations conducted upon the leasedlands. Bond Coverage is under Bond # NM 2308.

May 18, 2010Date Nanette Lupcho, Regulatory

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 8

CERTIFICATION:

I hereby certify that I, or persons under my direct supervision, have inspected the proposeddrill site and access route; that I am familiar with the conditions which currently exist; that thestatements made in this plan are, to the best of my knowledge, true and correct; and that thework associated with the operations proposed herein will be performed by EOG Resources,Inc. and its contractors and subcontractors in conformity with this plan and the terms andconditions under which it is approved. This statement is subject to the provisions of 18U.S.C. 1001 for the filing of a false statement.

Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, ofSection 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsibleunder the terms and conditions of the lease for the operations conducted upon the leasedlands. Bond Coverage is under Bond # NM 2308.

May 18, 2010Date Nanette Lupcho, Regulatory

'APIWellNo:43047511750000'

CHAPITA WELLS UNIT 1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25DSurface Use Plan Page 8

CERTIFICATION:

I hereby certify that I, or persons under my direct supervision, have inspected the proposeddrill site and access route; that I am familiar with the conditions which currently exist; that thestatements made in this plan are, to the best of my knowledge, true and correct; and that thework associated with the operations proposed herein will be performed by EOG Resources,Inc. and its contractors and subcontractors in conformity with this plan and the terms andconditions under which it is approved. This statement is subject to the provisions of 18U.S.C. 1001 for the filing of a false statement.

Please be advised that EOG Resources, Inc. is considered to be the operator of the CWU1535-25D, 1536-25D, 1537-25D, 1538-25D, 1539-25D, 1540-25D Wells, located in the NWNW, ofSection 25, T9S, R22E, Uintah County, Utah; Federal land and minerals; and is responsibleunder the terms and conditions of the lease for the operations conducted upon the leasedlands. Bond Coverage is under Bond # NM 2308.

May 18, 2010Date Nanette Lupcho, Regulatory

Page 34: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State OfficeP.O. Box 45155

Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells Unit Uintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of Land Management, the following wells are planned for calendar year 2010 within the Chapita Wells Unit, Uintah County, Utah.

API # WELL NAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 T09S R22E 0672 FNL 0756 FWLBHL Sec 25 T09S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 T09S R22E 0671 FNL 0776 FWLBHL Sec 25 T09S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 T09S R22E 0672 FNL 0766 FWLBHL Sec 25 T09S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 T09S R22E 0673 FNL 0746 FWLBHL Sec 25 T09S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 T09S R22E 0674 FNL 0726 FWLBHL Sec 25 T09S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 T09S R22E 0673 FNL 0736 FWLBHL Sec 25 T09S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at this time.

/s/ Michael L. Coulthard

'APIWellNo:43047511750000''APIWellNo:43047511750000'

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State Office

P.O. Box 45155Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells UnitUintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of LandManagement, the following wells are planned for calendar year2010 within the Chapita Wells Unit, Uintah County, Utah.

APl# WELLNAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 TO9S R22E 0672 FNL 0756 FWL

BHL Sec 25 TO9S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 TO9S R22E 0671 FNL 0776 FWL

BHL Sec 25 TO9S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 TO9S R22E 0672 FNL 0766 FWLBHL Sec 25 TO9S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 TO9S R22E 0673 FNL 0746 FWLBHL Sec 25 TO9S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 TO9S R22E 0674 FNL 0726 FWLBHL Sec 25 TO9S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 TO9S R22E 0673 FNL 0736 FWLBHL Sec 25 TO9S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at thistime .

/s/ Michael L.

'APIWellNo:43047511750000'

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State Office

P.O. Box 45155Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells UnitUintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of LandManagement, the following wells are planned for calendar year2010 within the Chapita Wells Unit, Uintah County, Utah.

APl# WELLNAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 TO9S R22E 0672 FNL 0756 FWL

BHL Sec 25 TO9S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 TO9S R22E 0671 FNL 0776 FWL

BHL Sec 25 TO9S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 TO9S R22E 0672 FNL 0766 FWLBHL Sec 25 TO9S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 TO9S R22E 0673 FNL 0746 FWLBHL Sec 25 TO9S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 TO9S R22E 0674 FNL 0726 FWLBHL Sec 25 TO9S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 TO9S R22E 0673 FNL 0736 FWLBHL Sec 25 TO9S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at thistime .

/s/ Michael L.

'APIWellNo:43047511750000'

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State Office

P.O. Box 45155Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells UnitUintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of LandManagement, the following wells are planned for calendar year2010 within the Chapita Wells Unit, Uintah County, Utah.

APl# WELLNAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 TO9S R22E 0672 FNL 0756 FWL

BHL Sec 25 TO9S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 TO9S R22E 0671 FNL 0776 FWL

BHL Sec 25 TO9S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 TO9S R22E 0672 FNL 0766 FWLBHL Sec 25 TO9S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 TO9S R22E 0673 FNL 0746 FWLBHL Sec 25 TO9S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 TO9S R22E 0674 FNL 0726 FWLBHL Sec 25 TO9S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 TO9S R22E 0673 FNL 0736 FWLBHL Sec 25 TO9S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at thistime .

/s/ Michael L.

'APIWellNo:43047511750000'

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State Office

P.O. Box 45155Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells UnitUintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of LandManagement, the following wells are planned for calendar year2010 within the Chapita Wells Unit, Uintah County, Utah.

APl# WELLNAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 TO9S R22E 0672 FNL 0756 FWL

BHL Sec 25 TO9S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 TO9S R22E 0671 FNL 0776 FWL

BHL Sec 25 TO9S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 TO9S R22E 0672 FNL 0766 FWLBHL Sec 25 TO9S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 TO9S R22E 0673 FNL 0746 FWLBHL Sec 25 TO9S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 TO9S R22E 0674 FNL 0726 FWLBHL Sec 25 TO9S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 TO9S R22E 0673 FNL 0736 FWLBHL Sec 25 TO9S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at thistime .

/s/ Michael L.

'APIWellNo:43047511750000'

United States Department of the Interior

BUREAU OF LAND MANAGEMENTUtah State Office

P.O. Box 45155Salt Lake City, Utah 84145-0155

IN REPLY REFER TO:3160(UT-922)

July 23, 2010Memorandum

To: Assistant District Manager Minerals, Vernal District

From: Michael Coulthard, Petroleum Engineer

Subject: 2010 Plan of Development Chapita Wells UnitUintah County, Utah.

Pursuant to email between Diana Whitney, Division of Oil, Gas andMining, and Mickey Coulthard, Utah State Office, Bureau of LandManagement, the following wells are planned for calendar year2010 within the Chapita Wells Unit, Uintah County, Utah.

APl# WELLNAME LOCATION

(Proposed PZ MESA VERDE)

43-047-51172 CWU 1535-25D Sec 25 TO9S R22E 0672 FNL 0756 FWL

BHL Sec 25 TO9S R22E 0032 FNL 0683 FWL

43-047-51173 CWU 1536-25D Sec 25 TO9S R22E 0671 FNL 0776 FWL

BHL Sec 25 TO9S R22E 0293 FNL 1046 FWL

43-047-51174 CWU 1537-25D Sec 25 TO9S R22E 0672 FNL 0766 FWLBHL Sec 25 TO9S R22E 0923 FNL 1243 FWL

43-047-51175 CWU 1538-25D Sec 25 TO9S R22E 0673 FNL 0746 FWLBHL Sec 25 TO9S R22E 1265 FNL 0659 FWL

43-047-51176 CWU 1539-25D Sec 25 TO9S R22E 0674 FNL 0726 FWLBHL Sec 25 TO9S R22E 0944 FNL 0379 FWL

43-047-51177 CWU 1540-25D Sec 25 TO9S R22E 0673 FNL 0736 FWLBHL Sec 25 TO9S R22E 0345 FNL 0418 FWL

This office has no objection to permitting the wells at thistime .

/s/ Michael L.

Page 35: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard:mc:7-23-10

'APIWellNo:43047511750000''APIWellNo:43047511750000'

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard: mc : 7 -2

'APIWellNo:43047511750000'

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard: mc : 7 -2

'APIWellNo:43047511750000'

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard: mc : 7 -2

'APIWellNo:43047511750000'

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard: mc : 7 -2

'APIWellNo:43047511750000'

bcc: File - Chapita Wells UnitDivision of Oil Gas and MiningCentral FilesAgr. Sec. ChronFluid Chron

MCoulthard: mc : 7 -2

Page 36: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â â

ââ

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

ââ

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

â

ª

ª

ª

ª

*

*

*

¸

*

ª

*

*

*

* ª

ª

*

*

ª

*

*

N

*

*

ª

*

N

¸

*

*

*

*

*

*

*

ª

*

*

ª

*

*

ª

*

*

*

*

*

ª

*

*

*

*

6

*

¸*

*

*

*

*

*

*

*

¸

*

¸*

*

¸

**

*

ª

N

*

*

ª*

**

*

*

*

*

*

*

*

*

*

*

* *

**

*

*

*

*

*

*

*

*

*

*

*

* *

*

*

* *

*

*

*

*

*

**

*

*

*

*

*

*

*

*

*

*

* *

*

**

*

*

*

*

*

*

**

*

*

*

*

*

*

*

*

*

*

*

*

* *

**

*

*

*

*

*

**

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

*

* *

*

* *

*

**

*

****

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

!!!!!!CWU 1540-25D 4304751177CWU 1539-25D 4304751176

CWU 1538-25D 4304751175

CWU 1537-25D 4304751174

CWU 1534-25D 4304751084

CWU 1533-25D 4304751083

CWU 4059-25 4304751079

CWU 1508-25D 4304751078

CWU 1393-26 4304751001

CWU 1526-24D 4304750966CWU 1525-24D 4304750965

CWU 1524-24D 4304750964

CWU 1523-24D 4304750963

CWU 1514-25D 4304750950

CWU 1513-25D 4304750949

CWU 1512-25D 4304750943

CWU 1511-25D 4304750942

CWU 1491-26D 4304750841CWU 1490-26D 4304750840

CWU 1489-26D 4304750839

CWU 1488-26D 4304750838

CWU 1486-26D 4304750830CWU 1485-26D 4304750829

CWU 1484-26D 4304750828

CWU 1483-26D 4304750827

CWU 1439-19 4304750588

CWU 1437-19 4304750544

CWU 1446-19 4304750542

CWU 1443-19 4304750540

CWU 1398-19 4304750539

CWU 1449-30 4304750410

CWU 4008-22 4304750376

CWU 782-23 4304750373

CWU 1440-19 4304750277

CWU 1413-19 4304750273

CWU 1395-26 4304750263

CWU 1435-19 4304750255

CWU 4003-30 4304750243

CWU 1410-23 4304750238

CWU 1411-23 4304750237

CWU 776-19 4304750138

CWU 756-25 4304750130

CWU 799-30 4304750121

CWU 1363-25H 4304750007

CWU 1441-19 4304740518

CWU 1397-24 4304740460

CWU 1416-23 4304740459

CWU 1368-30 4304740371

CWU 1133-19 4304740369

CWU 798-30 4304740336

CWU 774-19 4304740325

CWU 1358-24 4304740080

CWU 1131-19 4304740025

CWU 1366-19 4304739985

CWU 1361-25 4304739984

CWU 1359-24 4304739981

CWU 1367-30 4304739977

CWU 1369-30 4304739976

CWU 757-25 4304739948

CWU 1351-27 4304739928

CWU 1209-24 4304739908

CWU 1208-24 4304739907

CWU 1357-24 4304739900

CWU 1207-24 4304739899

CWU 1210-24 4304739898

CWU 1362-25 4304739882

NBU 606-35E 4304739797

CWU 1365-19 4304739779

CWU 1323-25D 4304739745

CWU 1320-25D 4304739744

CWU 1356-26 4304739731

CWU 935-25 4304739690

CWU 1080-25 4304739689

CWU 1354-23 4304739688

CWU 1355-23 4304739687CWU 1348-22

4304739686

CWU 1081-25 4304739678

CWU 1353-23 4304739677

CWU 1346-22 4304739652

CWU 1344-22 4304739623

CWU 1150-19 4304739618

CWU 1292-25 4304739609

CWU 1289-24 4304739470

CWU 1287-23 4304739451

CWU 1286-23 4304739450

NBU 603-35E 4304739306

NBU 604-35E 4304739302

CWU 1075-25 4304739186

CWU 941-26 4304738718

CWU 1277-22 4304738531

CWU 1077-25 4304738082

CWU 1079-25 4304737879

CWU 1078-25 4304737878

CWU 1043-23 4304737877

CWU 1158-26 4304737852

CWU 930-24 4304737848

CWU 927-24 4304737847

CWU 919-23 4304737846

CWU 924-23 4304737845CWU 923-23

4304737844

CWU 1085-30 4304737634

CWU 1089-22 4304737609

CWU 1086-22 4304737608

CWU 1155-24 4304737371

SOUTHMAN CYN 923-31C 4304737227

CWU 1063-24 4304737043

CWU 686-30 4304736960

CWU 682-30 4304736938

CWU 1006-22 4304736920

CWU 939-26 4304736696

CWU 950-30 4304736694

CWU 940-26 4304736691

NBU 922-36B 4304736500

NBU 922-36C 4304736397

CWU 933-25 4304736366

CWU 928-24 4304736342

CWU 921-23 4304736340

CWU 895-26 4304735544

CWU 904-26 4304735540

CWU 897-25 4304735538

CWU 901-24 4304735531

CWU 910-23 4304735529

CWU 908-23 4304735528

CWU 892-22 4304735526

CWU 900-24 4304735493

CWU 838-23 4304735220

CWU 824-23 4304735019

SOUTHMAN CYN 31-2X (RIG SKID) 4304734898

CWU 629-24 4304733939

CWU 506-27F 4304732833

CWU 358-23F 4304732548

CWU 340-26 4304732419

CWU 347-26N 4304732367

NBU 343-36E 4304732205

CWU 243-24 4304731485

CWU 234-23 4304731319

NBU 216-35 4304731284 NBU 213-36J

4304731268

CWU 46-30 4304730613

NBU 5-36B 4304730272

CWU 18 4304715063

B I T T E R C R E E K F I E L DB I T T E R C R E E K F I E L D

N A T U R A L B U T T E S U N I TN A T U R A L B U T T E S U N I T

23

26 25

24 19

30

3635

27

22

3134

14 131518

T 9 S R 22 ET 9 S R 23 E

Map Produced by Diana MasonMap Prepared:

Well Name: CWU 1538-25DAPI Number: 4304751175

Township 09.0 S Section 25Range 22.0 EMeridian: SLBM

F1,600 0 1,600800 Feet

1:15,030

UnitsSTATUS

ACTIVE

EXPLORATORY

GAS STORAGE

NF PP OIL

NF SECONDARY

PI OIL

PP GAS

PP GEOTHERML

PP OIL

SECONDARY

TERMINATED

FieldsSections

Township

Wells Query

D <all other values>

StatusAPD - Aproved Permit

H DRL - Spuded (Drilling Commenced)

4 GIW - Gas Injection

!* GS - Gas Storage

N LA - Location Abandoned

! LOC - New Location

7 OPS - Operation Suspended

ª PA - Plugged Abandoned

* PGW - Producing Gas Well

' POW - Producing Oil Well

O RET - Returned APD

¸ SGW - Shut-in Gas Well

· SOW - Shut-in Oil Well

6 TA - Temp. Abandoned

" TW - Test Well

¸ WDW - Water Disposal

¸ WIW - Water Injection Well

=* WSW - Water Supply Well

Tooele

Millard

Iron

San Juan

Kane

Juab

Uintah

Box Elder

Emery

Garfield

Grand

Utah

Beaver Wayne

Duchesne

Sevier

Summit

Rich

Washington

Carbon

Sanpete

Cache

Piute

Davis

Wasatch

Weber

DaggettSalt Lake

Morgan

Location Map

Operator: EOG RESOURCES, INC.

'APIW

ellNo:43047511750000'

1 _ - 1Ûg CWU 1g'7 19 API Number: 430475117515 4304750376, 14 cwu 1435 1 4304750544

A'WU 1086 22 CWU 782 23 CWU 1207 24 CWU 1208 24 4304750255 CWU 774 19 Well Name: CWU 1538-25D o4304737608 4304750373 4304739899 ^ 4304739907 CWU 113b)9 4304740325cwu io63 24 4304740025 Township 09.0 S Range 22.0 E Section 25

0WU 1344 22 CWU908 234304737043

CWU 1439 19 Meridian: SLBM304739623 4304735528 CWU 629 24 4304750588

CWU 838-23 CWU 1410 23 4304733939 CWU 1441 19 4 Operator: EOG RESOURCES, INC.4304735220 4304750238 CWU 1155 24 43g4740518

CWU 1286 23 CWU901 24 4304737371 CWU 776 19 CWU 1440 19 Map Prepared:CWU921 23 4304739450 4304735531 4304750138 4304750277 Map Produced by Diana Mason

CWU 1089;2 4304736340^ /LUy1430424

4304737609 CWU 1411 23 CWU 1357 24 + CWU 1443 19

CWU 3p8 23F CWU 1353 23 4304750237,, 4304739900 CWU 1209 24 4304760540 units weilscuery

4304732548 4304739677 CWU 1287 23 + 24 4304739908 CWU 1413 19 smius

22 , cwu 1346 22 4304739451 43°26°273

4304739652 23479327784274 . 4713 109824 LoRAvoRY errat

A 473562 CWU 924 23 CWU928 24 CWifl33 19 CWU 1446 19

CWu 234 23 CWU923 23 4304737845 4304736342 4304740369 4304750 4 seco oAav

4304731319 4304737844 1502293 CWU 1358 24 CWU 1359 24 CWU 1398 19CWU 1277 22 CWU 1354 23

4304740080 4304739981 4304750539× em tionAbandonea

4304738531 CWU 243-24 CWU 128 24 e Lac swoocatio4304739688 4304731485 43047394 CWU 930 24

CWU 1006 '2 CWU 7524 24D 24D ,

4304737848s coNomay 9966^oandoned

430473692( CWU 1043 23 4304750964 0966 CWU 900 24 - - CWU 1150 19 1 veo 336*ell

CWU 824 3 4304737877 CWU 1523 24$ U 1525 2 4304735493 4304739618 Fields Pow Producingaliweii

43047C39

1348 2247135658723

471444340473509630965

CWU 1508 25D

471379 471540449030

4304 39686 _ _ - - - - - - - CWU 1356 26 CWU 4059 25 CWU 1366 19 p erno Abando

ovvu i4ou au CWU 1491 26D 4304739731 43 4751079 4304739985 o Tw Testweli

4304 50839 4304750841 + CWU 1538 25D C' U 1540 25DC U 1534 25D

.,,,,o sa

CWU 1488 26DU 14904026D 4304751175 9047511

4 / wiw wateriniecionweii

4304 50838 CWU 1537 25D 4OtJ 1539 25 30475108325D 4304740336 e .vs .vatersuppie.veii

CWU 1158 26 4304751174CWU 13

CAU 1351 27 4304737852 430473 82 CWU 1085 3043(4739928 CWU 1393 26 CWU 1395 26 CWU 1292 25 4304737634

C/vU753026æ237F+4304751001 4743334204127502634

47 5585 04715501325D

43047 60904715501

' D 7047635

2310

CacheRichLocation Map

Web rCWU 939 26 CWU 1511 25D U 151 25D CWU 1367 30 .,

or4304736696 4304750942 750c 3 4304739977 summ Da

27- 6 c; u as 6,9,6,42,6 47

CWU 1323 25D

4715306030725H

638 0

alt

ate DuchesneUin

CWl 1078 254304739745 CWU 757 25 Juab

4304137878 CWU 1320 25D 4304739948 CWU 1368 30 Carbon

CWU 1 84 2 CWU 1486 26D 4304739744 4304740371 4430475 1828 4304750830 - C'/.U 1079 25 CWU 46 30 Millard

anpete

SWU 1485 26D 43(4737879 CWU 756 25 4304730613 Emery GrandCWU 1 83 26D 4304750829 4304750130

, CWU 1369 30sevier

430475 1827

CWU 940-26 CWU 941 264793395695 CWU 107 25 4304739976 Beaver Piute Wayne

4304736691 4304738718 CWU 1081 25 e CWU 108025, 4304739186 C/04745000234330

4304739678 4304739689 * CWU 950 30Garfeld

0473342736276NC 9054206

4713070K25 4304736694san Juan

SOUTHMAN CYN 923 31C

NBU 216 35 B ITTER CREEK F I ELD NBO47326236C 4NBU473262530604304737227

34 354N304763096E

4N304 630933056E 4N304753302

4N3047231132366J4S30UTH N CYN 31 2X (RIG SKIDI

NBU 604 35E NBU 343 36E1,600 soo o 1,eooFeet

4304739302 NATUR A L BUTTES UN I T 4304732205

1 _ - 1Ûg CWU 1g'7 19 API Number: 430475117515 4304750376, 14 cwu 1435 1 4304750544

A'WU 1086 22 CWU 782 23 CWU 1207 24 CWU 1208 24 4304750255 CWU 774 19 Well Name: CWU 1538-25D o4304737608 4304750373 4304739899 ^ 4304739907 CWU 1131. 9 4304740325cwu io63 24 ,. 4304740025 Township 09.0 S Range 22.0 E Section 25

0WU 1344 22 CWU908 234304737043

CWU 1439 19 Meridian: SLBM304739623 4304735528 CWU 629 24 4304750588

CWU 838-23 CWU 1410 23 4304733939 CWU 1441 19 4 Operator: EOG RESOURCES, INC.4304735220 4304750238 CWU 1155 24 43g4740518

CWU 1286 23 CWU901 24 4304737371 CWU 776 19 CWU 1440 19 Map Prepared:CWU921 23 4304739450 4304735531 4304750138 4304750277 Map Produced by Diana Mason

CWU 1089;2 4304736340^ /LUy14309424

4304737609 CWU 1411 23 CWU 1357 24 + CWU 1443 19

CWU 3p8 23F CWU 1353 23 4304750237,, 4304739900 CWU 1209 24 4304760540 units weilscuery

4304732548 4304739677 CWU 1287 23 + 24 4304739908 CWU 1413 19 smius

22 , cwu 1346 22 4304739451 43°26°273

4304739652 23479327784274 . 4713 109824 LoRAvoRY errat

A 473562 CWU 924 23 CWU928 24 CWifl33 19 CWU 1446 19

CWu 234 23 CWU923 23 4304737845 4304736342 4304740369 4304750 4seco oAav

4304731319 43047378441502293 CWU 1358 24 CWU 1359 24 CWU 1398 19

CWU 1277 22 CWU 1354 234304740080 4304739981

4304750539× em tionAbandonea

4304738531 CWU 243-24 CWU 128 24 e Lac swoocatio4304739688 4304731485 43047394 CWU 930 24

CWU 1006 '2 CWU 7524 24D 24D 4304737848s coNomay 9966^oandoned

430473692( CWU 1043 23 4304750964 0966 CWU 900 24 - - CWU 1150 19 1 veo 336*ell

CWU 824 3 4304737877 CWU 1523 24$ U 1525 2 4304735493 4304739618 Fields Pow Producingaliweii

43047C39

1348 22W47135658723

471444340473509630965

CWU 1508n25D

471379 471540449030

4304 39686 _ _ - - - - - - - CWU 1356 26 CWU 4059 25 CWU 1366 19 p rno Abando

ovvu i4ou au CWU 1491 26D 4304739731 43 4751079 4304739985 o Tw Testweli

4304 50839 4304750841 + CWU 1538 25D C' 1540 25DC U 1534 25D

.,,,,o sa

CWU 1488 26DU 14904026D 4304751175 3047511

84 wiw wateriniecionweii

4304 50838 CWU 1537 25D4

OtJ 1539 25 30475108325D 4304740336 e .vs .vatersuppie.veii

CWU 1158 26 4304751174CWU 13

CAU 1351 27 4304737852 430473 82 CWU 1085 3043(4739928 CWU 1393 26 CWU 1395 26 CWU 1292 25 4304737634

C/vU753026æ237F+4304751001 4743334204127502634

47 5585 C'704715501325D

43047 60904715501

' D 7047635

2310

CacheRichLocation Map

Web rCWU 939 26 CWU 1511 25D U 151 25D CWU 1367 30 .,

or4304736696 4304750942 750c 3 4304739977 summ Da

27' 6 c; u as 6,9,6,42,6 47

CWU 1323 25D

4715306030725H

638 0

alt

ate DuchesneUin

CWl 1078 254304739745 CWU 757 25 Juab

4304137878 CWU 1320 25D 4304739948 CWU 1368 30 Carbon

CWU 1 84 2 CWU 1486 26D 4304739744 4304740371 4430475 1828 4304750830 - C'/.U 1079 25 CWU 46 30 Millard

anpete

SWU 1485 26D 43(4737879 CWU 756 25 4304730613 Emery GrandCWU 1 83 26D 4304750829 4304750130

, CWU 1369 30sevier

430475 1827

CWU 940-26 CWU 941 264793395695 CWU 107 25 4304739976 Beaver Piute Wayne

4304736691 4304738718 CWU 1081 25 e CWU 108025, 4304739186 C/04745000234330

4304739678 4304739689 * CWU 950 30Garfeld

0473342736276NC 9054206

4713070K25 4304736694san Juan

SOUTHMAN CYN 923 31C

NBU 216 35 B ITTER CREEK F I ELD NBO47326236C 4NBU473262530604304737227

34 354N304763096E

4N304 630933056E 4N304753302

4N3047231132366J4S30UTH N CYN 31 2X (RIG SKIDI

NBU 604 35E NBU 343 36E1,600 soo o 1,eooFeet

4304739302 NATUR A L BUTTES UN I T 4304732205

1 _ - 1Ûg CWU 1g'7 19 API Number: 430475117515 4304750376, 14 cwu 1435 1 4304750544

A'WU 1086 22 CWU 782 23 CWU 1207 24 CWU 1208 24 4304750255 CWU 774 19 Well Name: CWU 1538-25D o4304737608 4304750373 4304739899 ^ 4304739907 CWU 1131. 9 4304740325cwu io63 24 ,. 4304740025 Township 09.0 S Range 22.0 E Section 25

0WU 1344 22 CWU908 234304737043

CWU 1439 19 Meridian: SLBM304739623 4304735528 CWU 629 24 4304750588

CWU 838-23 CWU 1410 23 4304733939 CWU 1441 19 4 Operator: EOG RESOURCES, INC.4304735220 4304750238 CWU 1155 24 43g4740518

CWU 1286 23 CWU901 24 4304737371 CWU 776 19 CWU 1440 19 Map Prepared:CWU921 23 4304739450 4304735531 4304750138 4304750277 Map Produced by Diana Mason

CWU 1089;2 4304736340^ /LUy14309424

4304737609 CWU 1411 23 CWU 1357 24 + CWU 1443 19

CWU 3p8 23F CWU 1353 23 4304750237,, 4304739900 CWU 1209 24 4304760540 units weilscuery

4304732548 4304739677 CWU 1287 23 + 24 4304739908 CWU 1413 19 smius

22 , cwu 1346 22 4304739451 43°26°273

4304739652 23479327784274 . 4713 109824 LoRAvoRY errat

A 473562 CWU 924 23 CWU928 24 CWifl33 19 CWU 1446 19

CWu 234 23 CWU923 23 4304737845 4304736342 4304740369 4304750 4seco oAav

4304731319 43047378441502293 CWU 1358 24 CWU 1359 24 CWU 1398 19

CWU 1277 22 CWU 1354 234304740080 4304739981

4304750539× em tionAbandonea

4304738531 CWU 243-24 CWU 128 24 e Lac swoocatio4304739688 4304731485 43047394 CWU 930 24

CWU 1006 '2 CWU 7524 24D 24D 4304737848s coNomay 9966^oandoned

430473692( CWU 1043 23 4304750964 0966 CWU 900 24 - - CWU 1150 19 1 veo 336*ell

CWU 824 3 4304737877 CWU 1523 24$ U 1525 2 4304735493 4304739618 Fields Pow Producingaliweii

43047C39

1348 22W47135658723

471444340473509630965

CWU 1508n25D

471379 471540449030

4304 39686 _ _ - - - - - - - CWU 1356 26 CWU 4059 25 CWU 1366 19 p rno Abando

ovvu i4ou au CWU 1491 26D 4304739731 43 4751079 4304739985 o Tw Testweli

4304 50839 4304750841 + CWU 1538 25D C' 1540 25DC U 1534 25D

.,,,,o sa

CWU 1488 26DU 14904026D 4304751175 3047511

84 wiw wateriniecionweii

4304 50838 CWU 1537 25D4

OtJ 1539 25 30475108325D 4304740336 e .vs .vatersuppie.veii

CWU 1158 26 4304751174CWU 13

CAU 1351 27 4304737852 430473 82 CWU 1085 3043(4739928 CWU 1393 26 CWU 1395 26 CWU 1292 25 4304737634

C/vU753026æ237F+4304751001 4743334204127502634

47 5585 C'704715501325D

43047 60904715501

' D 7047635

2310

CacheRichLocation Map

Web rCWU 939 26 CWU 1511 25D U 151 25D CWU 1367 30 .,

or4304736696 4304750942 750c 3 4304739977 summ Da

27' 6 c; u as 6,9,6,42,6 47

CWU 1323 25D

4715306030725H

638 0

alt

ate DuchesneUin

CWl 1078 254304739745 CWU 757 25 Juab

4304137878 CWU 1320 25D 4304739948 CWU 1368 30 Carbon

CWU 1 84 2 CWU 1486 26D 4304739744 4304740371 4430475 1828 4304750830 - C'/.U 1079 25 CWU 46 30 Millard

anpete

SWU 1485 26D 43(4737879 CWU 756 25 4304730613 Emery GrandCWU 1 83 26D 4304750829 4304750130

, CWU 1369 30sevier

430475 1827

CWU 940-26 CWU 941 264793395695 CWU 107 25 4304739976 Beaver Piute Wayne

4304736691 4304738718 CWU 1081 25 e CWU 108025, 4304739186 C/04745000234330

4304739678 4304739689 * CWU 950 30Garfeld

0473342736276NC 9054206

4713070K25 4304736694san Juan

SOUTHMAN CYN 923 31C

NBU 216 35 B ITTER CREEK F I ELD NBO47326236C 4NBU473262530604304737227

34 354N304763096E

4N304 630933056E 4N304753302

4N3047231132366J4S30UTH N CYN 31 2X (RIG SKIDI

NBU 604 35E NBU 343 36E1,600 soo o 1,eooFeet

4304739302 NATUR A L BUTTES UN I T 4304732205

1 _ - 1Ûg CWU 1g'7 19 API Number: 430475117515 4304750376, 14 cwu 1435 1 4304750544

A'WU 1086 22 CWU 782 23 CWU 1207 24 CWU 1208 24 4304750255 CWU 774 19 Well Name: CWU 1538-25D o4304737608 4304750373 4304739899 ^ 4304739907 CWU 1131. 9 4304740325cwu io63 24 ,. 4304740025 Township 09.0 S Range 22.0 E Section 25

0WU 1344 22 CWU908 234304737043

CWU 1439 19 Meridian: SLBM304739623 4304735528 CWU 629 24 4304750588

CWU 838-23 CWU 1410 23 4304733939 CWU 1441 19 4 Operator: EOG RESOURCES, INC.4304735220 4304750238 CWU 1155 24 43g4740518

CWU 1286 23 CWU901 24 4304737371 CWU 776 19 CWU 1440 19 Map Prepared:CWU921 23 4304739450 4304735531 4304750138 4304750277 Map Produced by Diana Mason

CWU 1089;2 4304736340^ /LUy14309424

4304737609 CWU 1411 23 CWU 1357 24 + CWU 1443 19

CWU 3p8 23F CWU 1353 23 4304750237,, 4304739900 CWU 1209 24 4304760540 units weilscuery

4304732548 4304739677 CWU 1287 23 + 24 4304739908 CWU 1413 19 smius

22 , cwu 1346 22 4304739451 43°26°273

4304739652 23479327784274 . 4713 109824 LoRAvoRY errat

A 473562 CWU 924 23 CWU928 24 CWifl33 19 CWU 1446 19

CWu 234 23 CWU923 23 4304737845 4304736342 4304740369 4304750 4seco oAav

4304731319 43047378441502293 CWU 1358 24 CWU 1359 24 CWU 1398 19

CWU 1277 22 CWU 1354 234304740080 4304739981

4304750539× em tionAbandonea

4304738531 CWU 243-24 CWU 128 24 e Lac swoocatio4304739688 4304731485 43047394 CWU 930 24

CWU 1006 '2 CWU 7524 24D 24D 4304737848s coNomay 9966^oandoned

430473692( CWU 1043 23 4304750964 0966 CWU 900 24 - - CWU 1150 19 1 veo 336*ell

CWU 824 3 4304737877 CWU 1523 24$ U 1525 2 4304735493 4304739618 Fields Pow Producingaliweii

43047C39

1348 22W47135658723

471444340473509630965

CWU 1508n25D

471379 471540449030

4304 39686 _ _ - - - - - - - CWU 1356 26 CWU 4059 25 CWU 1366 19 p rno Abando

ovvu i4ou au CWU 1491 26D 4304739731 43 4751079 4304739985 o Tw Testweli

4304 50839 4304750841 + CWU 1538 25D C' 1540 25DC U 1534 25D

.,,,,o sa

CWU 1488 26DU 14904026D 4304751175 3047511

84 wiw wateriniecionweii

4304 50838 CWU 1537 25D4

OtJ 1539 25 30475108325D 4304740336 e .vs .vatersuppie.veii

CWU 1158 26 4304751174CWU 13

CAU 1351 27 4304737852 430473 82 CWU 1085 3043(4739928 CWU 1393 26 CWU 1395 26 CWU 1292 25 4304737634

C/vU753026æ237F+4304751001 4743334204127502634

47 5585 C'704715501325D

43047 60904715501

' D 7047635

2310

CacheRichLocation Map

Web rCWU 939 26 CWU 1511 25D U 151 25D CWU 1367 30 .,

or4304736696 4304750942 750c 3 4304739977 summ Da

27' 6 c; u as 6,9,6,42,6 47

CWU 1323 25D

4715306030725H

638 0

alt

ate DuchesneUin

CWl 1078 254304739745 CWU 757 25 Juab

4304137878 CWU 1320 25D 4304739948 CWU 1368 30 Carbon

CWU 1 84 2 CWU 1486 26D 4304739744 4304740371 4430475 1828 4304750830 - C'/.U 1079 25 CWU 46 30 Millard

anpete

SWU 1485 26D 43(4737879 CWU 756 25 4304730613 Emery GrandCWU 1 83 26D 4304750829 4304750130

, CWU 1369 30sevier

430475 1827

CWU 940-26 CWU 941 264793395695 CWU 107 25 4304739976 Beaver Piute Wayne

4304736691 4304738718 CWU 1081 25 e CWU 108025, 4304739186 C/04745000234330

4304739678 4304739689 * CWU 950 30Garfeld

0473342736276NC 9054206

4713070K25 4304736694san Juan

SOUTHMAN CYN 923 31C

NBU 216 35 B ITTER CREEK F I ELD NBO47326236C 4NBU473262530604304737227

34 354N304763096E

4N304 630933056E 4N304753302

4N3047231132366J4S30UTH N CYN 31 2X (RIG SKIDI

NBU 604 35E NBU 343 36E1,600 soo o 1,eooFeet

4304739302 NATUR A L BUTTES UN I T 4304732205

1 _ - 1Ûg CWU 1g'7 19 API Number: 430475117515 4304750376, 14 cwu 1435 1 4304750544

A'WU 1086 22 CWU 782 23 CWU 1207 24 CWU 1208 24 4304750255 CWU 774 19 Well Name: CWU 1538-25D o4304737608 4304750373 4304739899 ^ 4304739907 CWU 1131. 9 4304740325cwu io63 24 ,. 4304740025 Township 09.0 S Range 22.0 E Section 25

0WU 1344 22 CWU908 234304737043

CWU 1439 19 Meridian: SLBM304739623 4304735528 CWU 629 24 4304750588

CWU 838-23 CWU 1410 23 4304733939 CWU 1441 19 4 Operator: EOG RESOURCES, INC.4304735220 4304750238 CWU 1155 24 43g4740518

CWU 1286 23 CWU901 24 4304737371 CWU 776 19 CWU 1440 19 Map Prepared:CWU921 23 4304739450 4304735531 4304750138 4304750277 Map Produced by Diana Mason

CWU 1089;2 4304736340^ /LUy14309424

4304737609 CWU 1411 23 CWU 1357 24 + CWU 1443 19

CWU 3p8 23F CWU 1353 23 4304750237,, 4304739900 CWU 1209 24 4304760540 units weilscuery

4304732548 4304739677 CWU 1287 23 + 24 4304739908 CWU 1413 19 smius

22 , cwu 1346 22 4304739451 43°26°273

4304739652 23479327784274 . 4713 109824 LoRAvoRY errat

A 473562 CWU 924 23 CWU928 24 CWifl33 19 CWU 1446 19

CWu 234 23 CWU923 23 4304737845 4304736342 4304740369 4304750 4seco oAav

4304731319 43047378441502293 CWU 1358 24 CWU 1359 24 CWU 1398 19

CWU 1277 22 CWU 1354 234304740080 4304739981

4304750539× em tionAbandonea

4304738531 CWU 243-24 CWU 128 24 e Lac swoocatio4304739688 4304731485 43047394 CWU 930 24

CWU 1006 '2 CWU 7524 24D 24D 4304737848s coNomay 9966^oandoned

430473692( CWU 1043 23 4304750964 0966 CWU 900 24 - - CWU 1150 19 1 veo 336*ell

CWU 824 3 4304737877 CWU 1523 24$ U 1525 2 4304735493 4304739618 Fields Pow Producingaliweii

43047C39

1348 22W47135658723

471444340473509630965

CWU 1508n25D

471379 471540449030

4304 39686 _ _ - - - - - - - CWU 1356 26 CWU 4059 25 CWU 1366 19 p rno Abando

ovvu i4ou au CWU 1491 26D 4304739731 43 4751079 4304739985 o Tw Testweli

4304 50839 4304750841 + CWU 1538 25D C' 1540 25DC U 1534 25D

.,,,,o sa

CWU 1488 26DU 14904026D 4304751175 3047511

84 wiw wateriniecionweii

4304 50838 CWU 1537 25D4

OtJ 1539 25 30475108325D 4304740336 e .vs .vatersuppie.veii

CWU 1158 26 4304751174CWU 13

CAU 1351 27 4304737852 430473 82 CWU 1085 3043(4739928 CWU 1393 26 CWU 1395 26 CWU 1292 25 4304737634

C/vU753026æ237F+4304751001 4743334204127502634

47 5585 C'704715501325D

43047 60904715501

' D 7047635

2310

CacheRichLocation Map

Web rCWU 939 26 CWU 1511 25D U 151 25D CWU 1367 30 .,

or4304736696 4304750942 750c 3 4304739977 summ Da

27' 6 c; u as 6,9,6,42,6 47

CWU 1323 25D

4715306030725H

638 0

alt

ate DuchesneUin

CWl 1078 254304739745 CWU 757 25 Juab

4304137878 CWU 1320 25D 4304739948 CWU 1368 30 Carbon

CWU 1 84 2 CWU 1486 26D 4304739744 4304740371 4430475 1828 4304750830 - C'/.U 1079 25 CWU 46 30 Millard

anpete

SWU 1485 26D 43(4737879 CWU 756 25 4304730613 Emery GrandCWU 1 83 26D 4304750829 4304750130

, CWU 1369 30sevier

430475 1827

CWU 940-26 CWU 941 264793395695 CWU 107 25 4304739976 Beaver Piute Wayne

4304736691 4304738718 CWU 1081 25 e CWU 108025, 4304739186 C/04745000234330

4304739678 4304739689 * CWU 950 30Garfeld

0473342736276NC 9054206

4713070K25 4304736694san Juan

SOUTHMAN CYN 923 31C

NBU 216 35 B ITTER CREEK F I ELD NBO47326236C 4NBU473262530604304737227

34 354N304763096E

4N304 630933056E 4N304753302

4N3047231132366J4S30UTH N CYN 31 2X (RIG SKIDI

NBU 604 35E NBU 343 36E1,600 soo o 1,eooFeet

4304739302 NATUR A L BUTTES UN I T 4304732205

Page 37: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTU0285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason 15 - Directional - dmason 17 - Oil Shale 190-5(b) - dmason

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTUO285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason15 - Directional - dmason17 - Oil Shale 190-5(b) -

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTUO285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason15 - Directional - dmason17 - Oil Shale 190-5(b) -

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTUO285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason15 - Directional - dmason17 - Oil Shale 190-5(b) -

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTUO285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason15 - Directional - dmason17 - Oil Shale 190-5(b) -

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 7/21/2010 API NO. ASSIGNED: 43047511750000

WELL NAME: CWU 1538-25D

OPERATOR: EOG Resources, Inc. (N9550) PHONE NUMBER: 435 781-9157

CONTACT: Nanette Lupcho

PROPOSED LOCATION: NWNW 25 090S 220E Permit Tech Review:

SURFACE: 0673 FNL 0746 FWL Engineering Review:

BOTTOM: 1265 FNL 0659 FWL Geology Review:

COUNTY: UINTAH

LATITUDE: 40.01246 LONGITUDE: -109.39435

UTM SURF EASTINGS: 637040.00 NORTHINGS: 4430165.00

FIELD NAME: NATURAL BUTTES

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTUO285A PROPOSED PRODUCING FORMATION(S): MESA VERDE

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - NM2308 Unit: CHAPITA WELLS

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 49-225 Board Cause No: Cause 179-8

RDCC Review: Effective Date: 8/10/1999

Fee Surface Agreement Siting: Suspends General Siting

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason15 - Directional - dmason17 - Oil Shale 190-5(b) -

Page 38: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Permit To Drill

******************Well Name:  CWU 1538-25D

API Well Number:  43047511750000

Lease Number:  UTU0285A

Surface Owner:   FEDERAL 

Approval Date:  8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1 et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling. 

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well. 

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division. 

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:   • Within 24 hours following the spudding of the well – contact Carol Daniels at 801-538-5284     (please leave a voicemail message if not available)

API Well No: 43047511750000API Well No: 43047511750000

State of UtahDEPARTMENT OF NATURAL RESOURCES

-/ MICHAEL R. STYLER

GAR . H BE RTExoutim Drotor

comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: CWU 1538-25DAPI Well Number: 43047511750000

Lease Number: UTUO285ASurface Owner: FEDERALApproval Date: 8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well.

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division.

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:

• Within 24 hours following the spudding of the well- contact Carol Daniels at 801-538-5284(please leave a voicemail message if not

API Well No: 43047511750000

State of UtahDEPARTMENT OF NATURAL RESOURCES

- -/ MICHAELR.STYLER

GAR'R H BERTExoutimDrotor

comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: CWU 1538-25DAPI Well Number: 43047511750000

Lease Number: UTUO285ASurface Owner: FEDERALApproval Date: 8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well.

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division.

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:

• Within 24 hours following the spudding of the well - contact Carol Daniels at 801-538-5284(please leave a voicemail message if not

API Well No: 43047511750000

State of UtahDEPARTMENT OF NATURAL RESOURCES

- -/ MICHAELR.STYLER

GAR'R H BERTExoutimDrotor

comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: CWU 1538-25DAPI Well Number: 43047511750000

Lease Number: UTUO285ASurface Owner: FEDERALApproval Date: 8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well.

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division.

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:

• Within 24 hours following the spudding of the well - contact Carol Daniels at 801-538-5284(please leave a voicemail message if not

API Well No: 43047511750000

State of UtahDEPARTMENT OF NATURAL RESOURCES

- -/ MICHAELR.STYLER

GAR'R H BERTExoutimDrotor

comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: CWU 1538-25DAPI Well Number: 43047511750000

Lease Number: UTUO285ASurface Owner: FEDERALApproval Date: 8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well.

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division.

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:

• Within 24 hours following the spudding of the well - contact Carol Daniels at 801-538-5284(please leave a voicemail message if not

API Well No: 43047511750000

State of UtahDEPARTMENT OF NATURAL RESOURCES

- -/ MICHAELR.STYLER

GAR'R H BERTExoutimDrotor

comrmr Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieuterant Gowrær Busion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: CWU 1538-25DAPI Well Number: 43047511750000

Lease Number: UTUO285ASurface Owner: FEDERALApproval Date: 8/2/2010

Issued to:EOG Resources, Inc., 1060 East Highway 40, Vernal, UT 84078

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of Cause 179-8. The expectedproducing formation or pool is the MESA VERDE Formation(s), completion into any other zoneswill require filing a Sundry Notice (Form 9). Completion and commingling of more than one poolwill require approval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

In accordance with Utah Admin. R.649-3-11, Directional Drilling, the operator shall submit acomplete angular deviation and directional survey report to the Division within 30 days followingcompletion of the well.

In accordance with the Order in Cause No. 190-5(b) dated October 28, 1982, the operator shallcomply with the requirements of Rules R649-3-31 and R649-3-27 pertaining to Designated Oil ShaleAreas. Additionally, the operators shall ensure that the surface and or production casing is properlycemented over the entire oil shale section as defined by Rule R649-3-31. The Operator shall reportthe actual depth the oil shale is encountered to the division.

Notification Requirements:The operator is required to notify the Division of Oil, Gas and Mining of the following actions duringdrilling of this well:

• Within 24 hours following the spudding of the well - contact Carol Daniels at 801-538-5284(please leave a voicemail message if not

Page 39: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

     OR     submit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas website     at https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:   • Entity Action Form (Form 6) – due within 5 days of spudding the well   • Monthly Status Report (Form 9) – due by 5th day of the following calendar month   • Requests to Change Plans (Form 9) – due prior to implementation   • Written Notice of Emergency Changes (Form 9) – due within 5 days   • Notice of Operations Suspension or Resumption (Form 9) – due prior to implementation   • Report of Water Encountered (Form 7) – due within 30 days after completion   • Well Completion Report (Form 8) – due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil & Gas 

API Well No: 43047511750000API Well No: 43047511750000

ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas websiteat https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:

• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil &

API Well No: 43047511750000

ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas websiteat https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:

• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil &

API Well No: 43047511750000

ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas websiteat https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:

• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil &

API Well No: 43047511750000

ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas websiteat https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:

• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil &

API Well No: 43047511750000

ORsubmit an electronic sundry notice (pre-registration required) via the Utah Oil & Gas websiteat https://oilgas.ogm.utah.gov

Reporting Requirements:All reports, forms and submittals as required by the Utah Oil and Gas Conservation General Ruleswill be promptly filed with the Division of Oil, Gas and Mining, including but not limited to:

• Entity Action Form (Form 6) - due within 5 days of spudding the well• Monthly Status Report (Form 9) - due by 5th day of the following calendar month• Requests to Change Plans (Form 9) - due prior to implementation• Written Notice of Emergency Changes (Form 9) - due within 5 days• Notice of Operations Suspension or Resumption (Form 9) - due prior to implementation• Report of Water Encountered (Form 7) - due within 30 days after completion• Well Completion Report (Form 8) - due within 30 days after completion or plugging

Approved By:

Acting Associate Director, Oil &

Page 40: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU0285A

SUNDRY NOTICES AND REPORTS ON WELLSDo not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TODRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

7.UNIT or CA AGREEMENT NAME: CHAPITA WELLS

1. TYPE OF WELL Gas Well

8. WELL NAME and NUMBER: CWU 1538-25D

2. NAME OF OPERATOR: EOG Resources, Inc.

9. API NUMBER: 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 Ext

9. FIELD and POOL or WILDCAT: NATURAL BUTTES

4. LOCATION OF WELL FOOTAGES AT SURFACE: 0673 FNL 0746 FWL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S

COUNTY: UINTAH

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

NOTICE OF INTENTApproximate date work will start:

8/2/2011

SUBSEQUENT REPORTDate of Work Completion:

SPUD REPORTDate of Spud:

DRILLING REPORTReport Date:

ACIDIZE ALTER CASING CASING REPAIR

CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

DEEPEN FRACTURE TREAT NEW CONSTRUCTION

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

NAME (PLEASE PRINT) PHONE NUMBER Mickenzie Gates 435 781-9145

TITLE Operations Clerk

SIGNATURE N/A

DATE 8/2/2011

08/03/2011

Aug. 02, 2011

Sundry Number: 17196 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING g-i-EA02E DEASIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. CHAPITA WELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 E×t NATURAL BUTTES

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: UINTAH

0673 FNL 0746 FWLQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWNW Section: 25 Township: 09.05 Range: 22.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

8/2/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 08/03/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMickenzie Gates 435 781-9145 Operations Clerk

SIGNATURE DATEN/A

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING g-i-EA02E DEASIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. CHAPITA WELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 E×t NATURAL BUTTES

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: UINTAH

0673 FNL 0746 FWLQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWNW Section: 25 Township: 09.05 Range: 22.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

8/2/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 08/03/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMickenzie Gates 435 781-9145 Operations Clerk

SIGNATURE DATEN/A

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING g-i-EA02E DEASIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. CHAPITA WELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 E×t NATURAL BUTTES

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: UINTAH

0673 FNL 0746 FWLQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWNW Section: 25 Township: 09.05 Range: 22.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

8/2/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 08/03/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMickenzie Gates 435 781-9145 Operations Clerk

SIGNATURE DATEN/A

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING g-i-EA02E DEASIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. CHAPITA WELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 E×t NATURAL BUTTES

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: UINTAH

0673 FNL 0746 FWLQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWNW Section: 25 Township: 09.05 Range: 22.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

8/2/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 08/03/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMickenzie Gates 435 781-9145 Operations Clerk

SIGNATURE DATEN/A

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING g-i-EA02E DEASIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. CHAPITA WELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:1060 East Highway 40 , Vernal, UT, 84078 435 781-9111 E×t NATURAL BUTTES

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: UINTAH

0673 FNL 0746 FWLQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWNW Section: 25 Township: 09.05 Range: 22.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

8/2/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced well beextended for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 08/03/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMickenzie Gates 435 781-9145 Operations Clerk

SIGNATURE DATEN/A

Page 41: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement beenupdated? Yes No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing orsiting requirements for this location? Yes No

Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? Yes No

Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? Yes No

Has the approved source of water for drilling changed? Yes No

Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? Yes No

Is bonding still in place, which covers this proposed well? Yes No

Signature: Mickenzie Gates Date: 8/2/2011

Title: Operations Clerk Representing: EOG RESOURCES, INC.

Aug. 02, 2011

Sundry Number: 17196 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesTI, GA% Pr NINTPM

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

• If located on private land, has the ownership changed, if so, has the surface agreement beenupdated? Yes © No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing orsiting requirements for this location? Yes © No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? Yes © No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? Yes © No

' Has the approved source of water for drilling changed? Yes © No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? Yes © No

' Is bonding still in place, which covers this proposed well? U Yes No

Signature: Mickenzie Gates Date: 8/2/2011Title: Operations Clerk Representing: EOG RESOURCES,

UTAH

DNR The Utah Division of Oil, Gas, and Mining- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesTI, BAS Pr N1NTMG

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located on private_land, has the ownership changed, if so, has the surface agreement beenupdated? O Yes No

• Have any wells been drilled in the vicinity of the roposed well which would affect the spacing orsiting requirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? O Yes @ No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? O Yes @ No

• Has the approved source of water for drilling changed? O Yes @ No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? O Yes @ No

• Is bonding still in place, which covers this proposed well? @ Yes O No

Signature: Mickenzie Gates Date: 8/2/2011Title: Operations Clerk Representing: EOG RESOURCES,

UTAH

DNR The Utah Division of Oil, Gas, and Mining- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesTI, BAS Pr N1NTMG

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located on private_land, has the ownership changed, if so, has the surface agreement beenupdated? O Yes No

• Have any wells been drilled in the vicinity of the roposed well which would affect the spacing orsiting requirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? O Yes @ No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? O Yes @ No

• Has the approved source of water for drilling changed? O Yes @ No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? O Yes @ No

• Is bonding still in place, which covers this proposed well? @ Yes O No

Signature: Mickenzie Gates Date: 8/2/2011Title: Operations Clerk Representing: EOG RESOURCES,

UTAH

DNR The Utah Division of Oil, Gas, and Mining- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesTI, BAS Pr N1NTMG

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located on private_land, has the ownership changed, if so, has the surface agreement beenupdated? O Yes No

• Have any wells been drilled in the vicinity of the roposed well which would affect the spacing orsiting requirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? O Yes @ No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? O Yes @ No

• Has the approved source of water for drilling changed? O Yes @ No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? O Yes @ No

• Is bonding still in place, which covers this proposed well? @ Yes O No

Signature: Mickenzie Gates Date: 8/2/2011Title: Operations Clerk Representing: EOG RESOURCES,

UTAH

DNR The Utah Division of Oil, Gas, and Mining- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesTI, BAS Pr N1NTMG

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located on private_land, has the ownership changed, if so, has the surface agreement beenupdated? O Yes No

• Have any wells been drilled in the vicinity of the roposed well which would affect the spacing orsiting requirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? O Yes @ No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? O Yes @ No

• Has the approved source of water for drilling changed? O Yes @ No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? O Yes @ No

• Is bonding still in place, which covers this proposed well? @ Yes O No

Signature: Mickenzie Gates Date: 8/2/2011Title: Operations Clerk Representing: EOG RESOURCES,

Page 42: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

3127) ÛË RECEIVED

UNITED STATESFORM APPROVED

DEPARTMENT OF THE INTERIORSEÎ Ë Û E ire Jl30120 06

BUREAU OF LAND MANAGEMENT 5. Lease Serial No.UTUO285A

APPLICATION FOR PERMIT TO DRILL OR REENTER 6. IfIndian, A1ÌotteeorTribeName

la. Type of Work: g Ï3RILL 0 REliNTER 7. If Unit or CA Agreement, Name and No.

8. Lease Name and WelÌNo.Ib. Type of Well: O Oil Well g Gas Well O Other g Single Zone O Multiple Zone CWU 1538-25D

2. Name of Operator Contact: NANI-IMH LUPCHO 9. API Well No.EOG RESOURCES INC E-Mail: [email protected]

3a. Address 3b. PÌ1oneNo. (include area code) 10.~Pieldand PooÍ,or Exploratory1060 EAST HIGHWAY 40 Ph: 435-781-9157 NATURALBUTTESVERNAL, UT 84078

4. Location of Well (Report location clearly and in accordance with any State requirements.*) I 1 Sec., T., R., M., or B1k. and Survey or Area

At surface NWNW 673FNL 746FWL 40.01240 N Lat 109.39509 W Lon Sec 25 T9S R22E Mer SLBAt proposed prod. zone NWNW 1265FNE659FWL 40.01078 N Lat; 10i39539 W Lon

14. Distance iti miles and directiontiom nearest towfi or post office* 12. County or Pans11 13. State50.5 MILES SOUTH OF VERNAL UINTAH UT

15. Distance from proposed locationto nearest property or 16. No. of Acres in Lease 17. Spacmg Unit dedicatedto t11iswelllease line, ft. (Also to nearest drig. unit line, if any)

659 FEET 1800.00

18. Distance from proposed locationto nearest well, drilling, 19. Proposed Depth 20. BLL1/BIA Bond No. on filecompleted, applied for, on this lease, ft.

APPROXIMATELY 430 FEET NE 9 MDD Â $ Û21. Elevations (Show whether DF, KB, RT, GL, etc. 22. Approximate datework will start 23. Estimated duration

5022 GL 45 DAYS

24. Attachments

The following, completed in accordance with the requirements of Onshore Oil and Gas Order No. 1, shall be attached to this form:

1. Well plat certified by a registered surveyor. 4. Bond to cover the operations unless covered by an existing bond on file (see2. A Drilling Plan. Item 20 above).3. A Surface Use Plan (if the location is on National Forest System Lands, the 5. Operator certification

SUPO shall be filed with the appropriate Forest Service Office). 6. Such other site specific infonnation and/or plans as may be required by theauthorized officer.

25. Signature Name (Pnnted/Typed) Date(Electronic Submission) NANETTE H LUPCHO Ph: 435-781-9157 07/21/2010

TitleREGULATORY ASSISTANT

Approved by (Signatu Name (Printed/Typed) J K k | Dateerry encz a | MARO8 201Title ' Ottice

VERNALFIELDOFFICEApplication approvaÌdoesnot warrant or cert te applicant holdslegalor equitable title to those rights m the subject leasewinch would entitle the applicant to conduct

oen itionnso aepopnroval,ifany,areattach-CONDITIONSOF APPROVALATTACHEDTitle 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crune for any person knowingly and willfully to make to any department or agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

Additional Operator Remarks (see next page) NOTICEOFAPPROVAElectronic Submission #90001 verified by the BLM Well Information System

For EOG RESOURCES INC, sent to the VernalCommitted to AFMSS for processing by ROBIN R. HANSEN on 07/27/2010 (10RRHDËËÔEIVED

MAR1 2 2012** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLÑÈÈÏISËlÚ*

3127) ÛË RECEIVED

UNITED STATESFORM APPROVED

DEPARTMENT OF THE INTERIORSEÎ Ë Û E ire Jl30120 06

BUREAU OF LAND MANAGEMENT 5. Lease Serial No.UTUO285A

APPLICATION FOR PERMIT TO DRILL OR REENTER 6. IfIndian, A1ÌotteeorTribeName

la. Type of Work: g Ï3RILL 0 REliNTER 7. If Unit or CA Agreement, Name and No.

8. Lease Name and WelÌNo.Ib. Type of Well: O Oil Well g Gas Well O Other g Single Zone O Multiple Zone CWU 1538-25D

2. Name of Operator Contact: NANI-IMH LUPCHO 9. API Well No.EOG RESOURCES INC E-Mail: [email protected]

3a. Address 3b. PÌ1oneNo. (include area code) 10.~Pieldand PooÍ,or Exploratory1060 EAST HIGHWAY 40 Ph: 435-781-9157 NATURALBUTTESVERNAL, UT 84078

4. Location of Well (Report location clearly and in accordance with any State requirements.*) I 1 Sec., T., R., M., or B1k. and Survey or Area

At surface NWNW 673FNL 746FWL 40.01240 N Lat 109.39509 W Lon Sec 25 T9S R22E Mer SLBAt proposed prod. zone NWNW 1265FNE659FWL 40.01078 N Lat; 10i39539 W Lon

14. Distance iti miles and directiontiom nearest towfi or post office* 12. County or Pans11 13. State50.5 MILES SOUTH OF VERNAL UINTAH UT

15. Distance from proposed locationto nearest property or 16. No. of Acres in Lease 17. Spacmg Unit dedicatedto t11iswelllease line, ft. (Also to nearest drig. unit line, if any)

659 FEET 1800.00

18. Distance from proposed locationto nearest well, drilling, 19. Proposed Depth 20. BLL1/BIA Bond No. on filecompleted, applied for, on this lease, ft.

APPROXIMATELY 430 FEET NE 9 MDD Â $ Û21. Elevations (Show whether DF, KB, RT, GL, etc. 22. Approximate datework will start 23. Estimated duration

5022 GL 45 DAYS

24. Attachments

The following, completed in accordance with the requirements of Onshore Oil and Gas Order No. 1, shall be attached to this form:

1. Well plat certified by a registered surveyor. 4. Bond to cover the operations unless covered by an existing bond on file (see2. A Drilling Plan. Item 20 above).3. A Surface Use Plan (if the location is on National Forest System Lands, the 5. Operator certification

SUPO shall be filed with the appropriate Forest Service Office). 6. Such other site specific infonnation and/or plans as may be required by theauthorized officer.

25. Signature Name (Pnnted/Typed) Date(Electronic Submission) NANETTE H LUPCHO Ph: 435-781-9157 07/21/2010

TitleREGULATORY ASSISTANT

Approved by (Signatu Name (Printed/Typed) J K k | Dateerry encz a | MARO8 201Title ' Ottice

VERNALFIELDOFFICEApplication approvaÌdoesnot warrant or cert te applicant holdslegalor equitable title to those rights m the subject leasewinch would entitle the applicant to conduct

oen itionnso aepopnroval,ifany,areattach-CONDITIONSOF APPROVALATTACHEDTitle 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crune for any person knowingly and willfully to make to any department or agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

Additional Operator Remarks (see next page) NOTICEOFAPPROVAElectronic Submission #90001 verified by the BLM Well Information System

For EOG RESOURCES INC, sent to the VernalCommitted to AFMSS for processing by ROBIN R. HANSEN on 07/27/2010 (10RRHDËËÔEIVED

MAR1 2 2012** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLÑÈÈÏISËlÚ*

3127) ÛË RECEIVED

UNITED STATESFORM APPROVED

DEPARTMENT OF THE INTERIORSEÎ Ë Û E ire Jl30120 06

BUREAU OF LAND MANAGEMENT 5. Lease Serial No.UTUO285A

APPLICATION FOR PERMIT TO DRILL OR REENTER 6. IfIndian, A1ÌotteeorTribeName

la. Type of Work: g Ï3RILL 0 REliNTER 7. If Unit or CA Agreement, Name and No.

8. Lease Name and WelÌNo.Ib. Type of Well: O Oil Well g Gas Well O Other g Single Zone O Multiple Zone CWU 1538-25D

2. Name of Operator Contact: NANI-IMH LUPCHO 9. API Well No.EOG RESOURCES INC E-Mail: [email protected]

3a. Address 3b. PÌ1oneNo. (include area code) 10.~Pieldand PooÍ,or Exploratory1060 EAST HIGHWAY 40 Ph: 435-781-9157 NATURALBUTTESVERNAL, UT 84078

4. Location of Well (Report location clearly and in accordance with any State requirements.*) I 1 Sec., T., R., M., or B1k. and Survey or Area

At surface NWNW 673FNL 746FWL 40.01240 N Lat 109.39509 W Lon Sec 25 T9S R22E Mer SLBAt proposed prod. zone NWNW 1265FNE659FWL 40.01078 N Lat; 10i39539 W Lon

14. Distance iti miles and directiontiom nearest towfi or post office* 12. County or Pans11 13. State50.5 MILES SOUTH OF VERNAL UINTAH UT

15. Distance from proposed locationto nearest property or 16. No. of Acres in Lease 17. Spacmg Unit dedicatedto t11iswelllease line, ft. (Also to nearest drig. unit line, if any)

659 FEET 1800.00

18. Distance from proposed locationto nearest well, drilling, 19. Proposed Depth 20. BLL1/BIA Bond No. on filecompleted, applied for, on this lease, ft.

APPROXIMATELY 430 FEET NE 9 MDD Â $ Û21. Elevations (Show whether DF, KB, RT, GL, etc. 22. Approximate datework will start 23. Estimated duration

5022 GL 45 DAYS

24. Attachments

The following, completed in accordance with the requirements of Onshore Oil and Gas Order No. 1, shall be attached to this form:

1. Well plat certified by a registered surveyor. 4. Bond to cover the operations unless covered by an existing bond on file (see2. A Drilling Plan. Item 20 above).3. A Surface Use Plan (if the location is on National Forest System Lands, the 5. Operator certification

SUPO shall be filed with the appropriate Forest Service Office). 6. Such other site specific infonnation and/or plans as may be required by theauthorized officer.

25. Signature Name (Pnnted/Typed) Date(Electronic Submission) NANETTE H LUPCHO Ph: 435-781-9157 07/21/2010

TitleREGULATORY ASSISTANT

Approved by (Signatu Name (Printed/Typed) J K k | Dateerry encz a | MARO8 201Title ' Ottice

VERNALFIELDOFFICEApplication approvaÌdoesnot warrant or cert te applicant holdslegalor equitable title to those rights m the subject leasewinch would entitle the applicant to conduct

oen itionnso aepopnroval,ifany,areattach-CONDITIONSOF APPROVALATTACHEDTitle 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crune for any person knowingly and willfully to make to any department or agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

Additional Operator Remarks (see next page) NOTICEOFAPPROVAElectronic Submission #90001 verified by the BLM Well Information System

For EOG RESOURCES INC, sent to the VernalCommitted to AFMSS for processing by ROBIN R. HANSEN on 07/27/2010 (10RRHDËËÔEIVED

MAR1 2 2012** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLÑÈÈÏISËlÚ*

3127) ÛË RECEIVED

UNITED STATESFORM APPROVED

DEPARTMENT OF THE INTERIORSEÎ Ë Û E ire Jl30120 06

BUREAU OF LAND MANAGEMENT 5. Lease Serial No.UTUO285A

APPLICATION FOR PERMIT TO DRILL OR REENTER 6. IfIndian, A1ÌotteeorTribeName

la. Type of Work: g Ï3RILL 0 REliNTER 7. If Unit or CA Agreement, Name and No.

8. Lease Name and WelÌNo.Ib. Type of Well: O Oil Well g Gas Well O Other g Single Zone O Multiple Zone CWU 1538-25D

2. Name of Operator Contact: NANI-IMH LUPCHO 9. API Well No.EOG RESOURCES INC E-Mail: [email protected]

3a. Address 3b. PÌ1oneNo. (include area code) 10.~Pieldand PooÍ,or Exploratory1060 EAST HIGHWAY 40 Ph: 435-781-9157 NATURALBUTTESVERNAL, UT 84078

4. Location of Well (Report location clearly and in accordance with any State requirements.*) I 1 Sec., T., R., M., or B1k. and Survey or Area

At surface NWNW 673FNL 746FWL 40.01240 N Lat 109.39509 W Lon Sec 25 T9S R22E Mer SLBAt proposed prod. zone NWNW 1265FNE659FWL 40.01078 N Lat; 10i39539 W Lon

14. Distance iti miles and directiontiom nearest towfi or post office* 12. County or Pans11 13. State50.5 MILES SOUTH OF VERNAL UINTAH UT

15. Distance from proposed locationto nearest property or 16. No. of Acres in Lease 17. Spacmg Unit dedicatedto t11iswelllease line, ft. (Also to nearest drig. unit line, if any)

659 FEET 1800.00

18. Distance from proposed locationto nearest well, drilling, 19. Proposed Depth 20. BLL1/BIA Bond No. on filecompleted, applied for, on this lease, ft.

APPROXIMATELY 430 FEET NE 9 MDD Â $ Û21. Elevations (Show whether DF, KB, RT, GL, etc. 22. Approximate datework will start 23. Estimated duration

5022 GL 45 DAYS

24. Attachments

The following, completed in accordance with the requirements of Onshore Oil and Gas Order No. 1, shall be attached to this form:

1. Well plat certified by a registered surveyor. 4. Bond to cover the operations unless covered by an existing bond on file (see2. A Drilling Plan. Item 20 above).3. A Surface Use Plan (if the location is on National Forest System Lands, the 5. Operator certification

SUPO shall be filed with the appropriate Forest Service Office). 6. Such other site specific infonnation and/or plans as may be required by theauthorized officer.

25. Signature Name (Pnnted/Typed) Date(Electronic Submission) NANETTE H LUPCHO Ph: 435-781-9157 07/21/2010

TitleREGULATORY ASSISTANT

Approved by (Signatu Name (Printed/Typed) J K k | Dateerry encz a | MARO8 201Title ' Ottice

VERNALFIELDOFFICEApplication approvaÌdoesnot warrant or cert te applicant holdslegalor equitable title to those rights m the subject leasewinch would entitle the applicant to conduct

oen itionnso aepopnroval,ifany,areattach-CONDITIONSOF APPROVALATTACHEDTitle 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crune for any person knowingly and willfully to make to any department or agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

Additional Operator Remarks (see next page) NOTICEOFAPPROVAElectronic Submission #90001 verified by the BLM Well Information System

For EOG RESOURCES INC, sent to the VernalCommitted to AFMSS for processing by ROBIN R. HANSEN on 07/27/2010 (10RRHDËËÔEIVED

MAR1 2 2012** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLÑÈÈÏISËlÚ*

3127) ÛË RECEIVED

UNITED STATESFORM APPROVED

DEPARTMENT OF THE INTERIORSEÎ Ë Û E ire Jl30120 06

BUREAU OF LAND MANAGEMENT 5. Lease Serial No.UTUO285A

APPLICATION FOR PERMIT TO DRILL OR REENTER 6. IfIndian, A1ÌotteeorTribeName

la. Type of Work: g Ï3RILL 0 REliNTER 7. If Unit or CA Agreement, Name and No.

8. Lease Name and WelÌNo.Ib. Type of Well: O Oil Well g Gas Well O Other g Single Zone O Multiple Zone CWU 1538-25D

2. Name of Operator Contact: NANI-IMH LUPCHO 9. API Well No.EOG RESOURCES INC E-Mail: [email protected]

3a. Address 3b. PÌ1oneNo. (include area code) 10.~Pieldand PooÍ,or Exploratory1060 EAST HIGHWAY 40 Ph: 435-781-9157 NATURALBUTTESVERNAL, UT 84078

4. Location of Well (Report location clearly and in accordance with any State requirements.*) I 1 Sec., T., R., M., or B1k. and Survey or Area

At surface NWNW 673FNL 746FWL 40.01240 N Lat 109.39509 W Lon Sec 25 T9S R22E Mer SLBAt proposed prod. zone NWNW 1265FNE659FWL 40.01078 N Lat; 10i39539 W Lon

14. Distance iti miles and directiontiom nearest towfi or post office* 12. County or Pans11 13. State50.5 MILES SOUTH OF VERNAL UINTAH UT

15. Distance from proposed locationto nearest property or 16. No. of Acres in Lease 17. Spacmg Unit dedicatedto t11iswelllease line, ft. (Also to nearest drig. unit line, if any)

659 FEET 1800.00

18. Distance from proposed locationto nearest well, drilling, 19. Proposed Depth 20. BLL1/BIA Bond No. on filecompleted, applied for, on this lease, ft.

APPROXIMATELY 430 FEET NE 9 MDD Â $ Û21. Elevations (Show whether DF, KB, RT, GL, etc. 22. Approximate datework will start 23. Estimated duration

5022 GL 45 DAYS

24. Attachments

The following, completed in accordance with the requirements of Onshore Oil and Gas Order No. 1, shall be attached to this form:

1. Well plat certified by a registered surveyor. 4. Bond to cover the operations unless covered by an existing bond on file (see2. A Drilling Plan. Item 20 above).3. A Surface Use Plan (if the location is on National Forest System Lands, the 5. Operator certification

SUPO shall be filed with the appropriate Forest Service Office). 6. Such other site specific infonnation and/or plans as may be required by theauthorized officer.

25. Signature Name (Pnnted/Typed) Date(Electronic Submission) NANETTE H LUPCHO Ph: 435-781-9157 07/21/2010

TitleREGULATORY ASSISTANT

Approved by (Signatu Name (Printed/Typed) J K k | Dateerry encz a | MARO8 201Title ' Ottice

VERNALFIELDOFFICEApplication approvaÌdoesnot warrant or cert te applicant holdslegalor equitable title to those rights m the subject leasewinch would entitle the applicant to conduct

oen itionnso aepopnroval,ifany,areattach-CONDITIONSOF APPROVALATTACHEDTitle 18 U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crune for any person knowingly and willfully to make to any department or agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

Additional Operator Remarks (see next page) NOTICEOFAPPROVAElectronic Submission #90001 verified by the BLM Well Information System

For EOG RESOURCES INC, sent to the VernalCommitted to AFMSS for processing by ROBIN R. HANSEN on 07/27/2010 (10RRHDËËÔEIVED

MAR1 2 2012** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLÑÈÈÏISËlÚ*

Page 43: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

UNITED STATES DEPARTMENT OF THE INTERIORBUREAU OF LAND MANAGEMENT

VERNAL FIELD OFFICEen a

#* 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATION FOR PERMIT TO DRILL

Company: EOG Resource, Inc. Location: NWNW, Sec. 25,T9S, R22E(S)NWNW, Sec. 25, T9S, R22E (B)

Well No: CWU 1538-25D Lease No: UTU-0285AAPI No: 43-047-51175 Agreement: Chapita Wells Unit

OFFICE NUMBER: (435) 781-4400

OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actionsof his subcontractors. A copy of the approved APD must be on location during construction, drilling, andcompletion operations. This permit is approved for a two (2) year period, or until lease expiration,whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundrynotice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of location and(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.(Notify Environmental Scientist)

Spud Notice - Twenty-Four (24) hours prior to spudding the well.(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

BOP & Related Equipment Tests - Twenty-Four (24) hours prior to initiating pressure tests.(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or(Notify Petroleum Engineer) production resumes after well has been off production for

more than ninety (90)

UNITED STATES DEPARTMENT OF THE INTERIORBUREAU OF LAND MANAGEMENT

VERNAL FIELD OFFICEen a

#* 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATION FOR PERMIT TO DRILL

Company: EOG Resource, Inc. Location: NWNW, Sec. 25,T9S, R22E(S)NWNW, Sec. 25, T9S, R22E (B)

Well No: CWU 1538-25D Lease No: UTU-0285AAPI No: 43-047-51175 Agreement: Chapita Wells Unit

OFFICE NUMBER: (435) 781-4400

OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actionsof his subcontractors. A copy of the approved APD must be on location during construction, drilling, andcompletion operations. This permit is approved for a two (2) year period, or until lease expiration,whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundrynotice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of location and(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.(Notify Environmental Scientist)

Spud Notice - Twenty-Four (24) hours prior to spudding the well.(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

BOP & Related Equipment Tests - Twenty-Four (24) hours prior to initiating pressure tests.(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or(Notify Petroleum Engineer) production resumes after well has been off production for

more than ninety (90)

UNITED STATES DEPARTMENT OF THE INTERIORBUREAU OF LAND MANAGEMENT

VERNAL FIELD OFFICEen a

#* 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATION FOR PERMIT TO DRILL

Company: EOG Resource, Inc. Location: NWNW, Sec. 25,T9S, R22E(S)NWNW, Sec. 25, T9S, R22E (B)

Well No: CWU 1538-25D Lease No: UTU-0285AAPI No: 43-047-51175 Agreement: Chapita Wells Unit

OFFICE NUMBER: (435) 781-4400

OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actionsof his subcontractors. A copy of the approved APD must be on location during construction, drilling, andcompletion operations. This permit is approved for a two (2) year period, or until lease expiration,whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundrynotice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of location and(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.(Notify Environmental Scientist)

Spud Notice - Twenty-Four (24) hours prior to spudding the well.(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

BOP & Related Equipment Tests - Twenty-Four (24) hours prior to initiating pressure tests.(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or(Notify Petroleum Engineer) production resumes after well has been off production for

more than ninety (90)

UNITED STATES DEPARTMENT OF THE INTERIORBUREAU OF LAND MANAGEMENT

VERNAL FIELD OFFICEen a

#* 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATION FOR PERMIT TO DRILL

Company: EOG Resource, Inc. Location: NWNW, Sec. 25,T9S, R22E(S)NWNW, Sec. 25, T9S, R22E (B)

Well No: CWU 1538-25D Lease No: UTU-0285AAPI No: 43-047-51175 Agreement: Chapita Wells Unit

OFFICE NUMBER: (435) 781-4400

OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actionsof his subcontractors. A copy of the approved APD must be on location during construction, drilling, andcompletion operations. This permit is approved for a two (2) year period, or until lease expiration,whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundrynotice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of location and(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.(Notify Environmental Scientist)

Spud Notice - Twenty-Four (24) hours prior to spudding the well.(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

BOP & Related Equipment Tests - Twenty-Four (24) hours prior to initiating pressure tests.(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or(Notify Petroleum Engineer) production resumes after well has been off production for

more than ninety (90)

UNITED STATES DEPARTMENT OF THE INTERIORBUREAU OF LAND MANAGEMENT

VERNAL FIELD OFFICEen a

#* 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATION FOR PERMIT TO DRILL

Company: EOG Resource, Inc. Location: NWNW, Sec. 25,T9S, R22E(S)NWNW, Sec. 25, T9S, R22E (B)

Well No: CWU 1538-25D Lease No: UTU-0285AAPI No: 43-047-51175 Agreement: Chapita Wells Unit

OFFICE NUMBER: (435) 781-4400

OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actionsof his subcontractors. A copy of the approved APD must be on location during construction, drilling, andcompletion operations. This permit is approved for a two (2) year period, or until lease expiration,whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundrynotice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of location and(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.(Notify Environmental Scientist)

Spud Notice - Twenty-Four (24) hours prior to spudding the well.(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

BOP & Related Equipment Tests - Twenty-Four (24) hours prior to initiating pressure tests.(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or(Notify Petroleum Engineer) production resumes after well has been off production for

more than ninety (90)

Page 44: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 2 of 8Well: CWU 1538-25D

3/2/2012

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirementdoes not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

• No construction, drilling or completion operations will occur within 0.25 miles of burrowing owlnesting habitat from March 1 through August 31.

• If it is anticipated that construction or drilling will occur during the given timing restriction, a BLMor qualified biologist shall be notified to conduct surveys for raptors. Depending upon the results ofthe surveys, permission to proceed may or may not be granted by the Authorized Officer.

• Construction of the pad, road and associated pipeline for CWU 1535-25D, 1536-25D, 1537-25D,1538-25D, 1539-25D, and 1540-25D will be monitored by a permitted paleontologist.

• If during the construction of any wells evaluated in this document, any vertebrate paleontologicalresources are discovered, all operations effecting such sites shall be immediately suspended, and alldiscoveries shall be left intact until authorized to proceed by the authorized officer.

• All vehicular traffic, personnel movement, construction and restoration activities will be confined toareas cleared by the site inventory and to existing roads.

• Applicant Committed Mitigation:o All new and replacement internal combustion gas field engines of less than or equal to 300

design-rated horse power must not emit more than 2 grams of NOx per horsepower-hour.This requirement does not apply to gas field engines of less than or equal to 40 design-ratedhorsepower-hour.

o All new and replacement internal combustion gas field engines of greater than 300 designrated horsepower must not emit more than 1.0 gram of NOx per horsepower-hour.

o Emissions will be routed from existing TEG dehydrators to control devices.o Heat trace pump exhaust will be routed to burners or control devices.o Control devices will be installed for tank flash on production facilities with greater than 8 tpy

VOC emissions.o Low bleed controllers will be installed on new equipment or retrofit to existing equipment.o Desiccant dehydration equipment will be utilized on all new production facilities and retrofit

existing TEG dehydrators with desiccant

Page 2 of 8Well: CWU 1538-25D

3/2/2012

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirementdoes not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

• No construction, drilling or completion operations will occur within 0.25 miles of burrowing owlnesting habitat from March 1 through August 31.

• If it is anticipated that construction or drilling will occur during the given timing restriction, a BLMor qualified biologist shall be notified to conduct surveys for raptors. Depending upon the results ofthe surveys, permission to proceed may or may not be granted by the Authorized Officer.

• Construction of the pad, road and associated pipeline for CWU 1535-25D, 1536-25D, 1537-25D,1538-25D, 1539-25D, and 1540-25D will be monitored by a permitted paleontologist.

• If during the construction of any wells evaluated in this document, any vertebrate paleontologicalresources are discovered, all operations effecting such sites shall be immediately suspended, and alldiscoveries shall be left intact until authorized to proceed by the authorized officer.

• All vehicular traffic, personnel movement, construction and restoration activities will be confined toareas cleared by the site inventory and to existing roads.

• Applicant Committed Mitigation:o All new and replacement internal combustion gas field engines of less than or equal to 300

design-rated horse power must not emit more than 2 grams of NOx per horsepower-hour.This requirement does not apply to gas field engines of less than or equal to 40 design-ratedhorsepower-hour.

o All new and replacement internal combustion gas field engines of greater than 300 designrated horsepower must not emit more than 1.0 gram of NOx per horsepower-hour.

o Emissions will be routed from existing TEG dehydrators to control devices.o Heat trace pump exhaust will be routed to burners or control devices.o Control devices will be installed for tank flash on production facilities with greater than 8 tpy

VOC emissions.o Low bleed controllers will be installed on new equipment or retrofit to existing equipment.o Desiccant dehydration equipment will be utilized on all new production facilities and retrofit

existing TEG dehydrators with desiccant

Page 2 of 8Well: CWU 1538-25D

3/2/2012

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirementdoes not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

• No construction, drilling or completion operations will occur within 0.25 miles of burrowing owlnesting habitat from March 1 through August 31.

• If it is anticipated that construction or drilling will occur during the given timing restriction, a BLMor qualified biologist shall be notified to conduct surveys for raptors. Depending upon the results ofthe surveys, permission to proceed may or may not be granted by the Authorized Officer.

• Construction of the pad, road and associated pipeline for CWU 1535-25D, 1536-25D, 1537-25D,1538-25D, 1539-25D, and 1540-25D will be monitored by a permitted paleontologist.

• If during the construction of any wells evaluated in this document, any vertebrate paleontologicalresources are discovered, all operations effecting such sites shall be immediately suspended, and alldiscoveries shall be left intact until authorized to proceed by the authorized officer.

• All vehicular traffic, personnel movement, construction and restoration activities will be confined toareas cleared by the site inventory and to existing roads.

• Applicant Committed Mitigation:o All new and replacement internal combustion gas field engines of less than or equal to 300

design-rated horse power must not emit more than 2 grams of NOx per horsepower-hour.This requirement does not apply to gas field engines of less than or equal to 40 design-ratedhorsepower-hour.

o All new and replacement internal combustion gas field engines of greater than 300 designrated horsepower must not emit more than 1.0 gram of NOx per horsepower-hour.

o Emissions will be routed from existing TEG dehydrators to control devices.o Heat trace pump exhaust will be routed to burners or control devices.o Control devices will be installed for tank flash on production facilities with greater than 8 tpy

VOC emissions.o Low bleed controllers will be installed on new equipment or retrofit to existing equipment.o Desiccant dehydration equipment will be utilized on all new production facilities and retrofit

existing TEG dehydrators with desiccant

Page 2 of 8Well: CWU 1538-25D

3/2/2012

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirementdoes not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

• No construction, drilling or completion operations will occur within 0.25 miles of burrowing owlnesting habitat from March 1 through August 31.

• If it is anticipated that construction or drilling will occur during the given timing restriction, a BLMor qualified biologist shall be notified to conduct surveys for raptors. Depending upon the results ofthe surveys, permission to proceed may or may not be granted by the Authorized Officer.

• Construction of the pad, road and associated pipeline for CWU 1535-25D, 1536-25D, 1537-25D,1538-25D, 1539-25D, and 1540-25D will be monitored by a permitted paleontologist.

• If during the construction of any wells evaluated in this document, any vertebrate paleontologicalresources are discovered, all operations effecting such sites shall be immediately suspended, and alldiscoveries shall be left intact until authorized to proceed by the authorized officer.

• All vehicular traffic, personnel movement, construction and restoration activities will be confined toareas cleared by the site inventory and to existing roads.

• Applicant Committed Mitigation:o All new and replacement internal combustion gas field engines of less than or equal to 300

design-rated horse power must not emit more than 2 grams of NOx per horsepower-hour.This requirement does not apply to gas field engines of less than or equal to 40 design-ratedhorsepower-hour.

o All new and replacement internal combustion gas field engines of greater than 300 designrated horsepower must not emit more than 1.0 gram of NOx per horsepower-hour.

o Emissions will be routed from existing TEG dehydrators to control devices.o Heat trace pump exhaust will be routed to burners or control devices.o Control devices will be installed for tank flash on production facilities with greater than 8 tpy

VOC emissions.o Low bleed controllers will be installed on new equipment or retrofit to existing equipment.o Desiccant dehydration equipment will be utilized on all new production facilities and retrofit

existing TEG dehydrators with desiccant

Page 2 of 8Well: CWU 1538-25D

3/2/2012

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirementdoes not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

• No construction, drilling or completion operations will occur within 0.25 miles of burrowing owlnesting habitat from March 1 through August 31.

• If it is anticipated that construction or drilling will occur during the given timing restriction, a BLMor qualified biologist shall be notified to conduct surveys for raptors. Depending upon the results ofthe surveys, permission to proceed may or may not be granted by the Authorized Officer.

• Construction of the pad, road and associated pipeline for CWU 1535-25D, 1536-25D, 1537-25D,1538-25D, 1539-25D, and 1540-25D will be monitored by a permitted paleontologist.

• If during the construction of any wells evaluated in this document, any vertebrate paleontologicalresources are discovered, all operations effecting such sites shall be immediately suspended, and alldiscoveries shall be left intact until authorized to proceed by the authorized officer.

• All vehicular traffic, personnel movement, construction and restoration activities will be confined toareas cleared by the site inventory and to existing roads.

• Applicant Committed Mitigation:o All new and replacement internal combustion gas field engines of less than or equal to 300

design-rated horse power must not emit more than 2 grams of NOx per horsepower-hour.This requirement does not apply to gas field engines of less than or equal to 40 design-ratedhorsepower-hour.

o All new and replacement internal combustion gas field engines of greater than 300 designrated horsepower must not emit more than 1.0 gram of NOx per horsepower-hour.

o Emissions will be routed from existing TEG dehydrators to control devices.o Heat trace pump exhaust will be routed to burners or control devices.o Control devices will be installed for tank flash on production facilities with greater than 8 tpy

VOC emissions.o Low bleed controllers will be installed on new equipment or retrofit to existing equipment.o Desiccant dehydration equipment will be utilized on all new production facilities and retrofit

existing TEG dehydrators with desiccant

Page 45: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 3 of 8Well: CWU 1538-25D

3/2/2012

o A thief hatch/enardo inspection and replacement program will be established to minimizetank losses.

o Well visits will be minimized using telemetry.o Ozone generation will be minimized by reasonable operational procedures.o If pump jacksare required, then hospital mufflers will be

Page 3 of 8Well: CWU 1538-25D

3/2/2012

o A thief hatch/enardo inspection and replacement program will be established to minimizetank losses.

o Well visits will be minimized using telemetry.o Ozone generation will be minimized by reasonable operational procedures.o If pump jacksare required, then hospital mufflers will be

Page 3 of 8Well: CWU 1538-25D

3/2/2012

o A thief hatch/enardo inspection and replacement program will be established to minimizetank losses.

o Well visits will be minimized using telemetry.o Ozone generation will be minimized by reasonable operational procedures.o If pump jacksare required, then hospital mufflers will be

Page 3 of 8Well: CWU 1538-25D

3/2/2012

o A thief hatch/enardo inspection and replacement program will be established to minimizetank losses.

o Well visits will be minimized using telemetry.o Ozone generation will be minimized by reasonable operational procedures.o If pump jacksare required, then hospital mufflers will be

Page 3 of 8Well: CWU 1538-25D

3/2/2012

o A thief hatch/enardo inspection and replacement program will be established to minimizetank losses.

o Well visits will be minimized using telemetry.o Ozone generation will be minimized by reasonable operational procedures.o If pump jacksare required, then hospital mufflers will be

Page 46: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 4 of 8Well: CWU 1538-25D

3/2/2012

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Variance requests listed in section seven (7) of your drilling plan are approved.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLINGICOMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the BLM. If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses submitted to the BLM VernalField

Page 4 of 8Well: CWU 1538-25D

3/2/2012

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Variance requests listed in section seven (7) of your drilling plan are approved.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLINGICOMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the BLM. If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses submitted to the BLM VernalField

Page 4 of 8Well: CWU 1538-25D

3/2/2012

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Variance requests listed in section seven (7) of your drilling plan are approved.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLINGICOMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the BLM. If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses submitted to the BLM VernalField

Page 4 of 8Well: CWU 1538-25D

3/2/2012

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Variance requests listed in section seven (7) of your drilling plan are approved.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLINGICOMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the BLM. If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses submitted to the BLM VernalField

Page 4 of 8Well: CWU 1538-25D

3/2/2012

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Variance requests listed in section seven (7) of your drilling plan are approved.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLINGICOMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the BLM. If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses submitted to the BLM VernalField

Page 47: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 5 of 8Well: CWU 1538-25D

3/2/2012

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation musthave prior approval from the BLM Vernal Field

Page 5 of 8Well: CWU 1538-25D

3/2/2012

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation musthave prior approval from the BLM Vernal Field

Page 5 of 8Well: CWU 1538-25D

3/2/2012

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation musthave prior approval from the BLM Vernal Field

Page 5 of 8Well: CWU 1538-25D

3/2/2012

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation musthave prior approval from the BLM Vernal Field

Page 5 of 8Well: CWU 1538-25D

3/2/2012

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation musthave prior approval from the BLM Vernal Field

Page 48: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 6 of 8Well: CWU 1538-25D

3/2/2012

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or marker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• For information regarding production reporting, contact the Office of Natural ResourcesRevenue (ONRR) at www.ONRR.gov.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production.

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion

Page 6 of 8Well: CWU 1538-25D

3/2/2012

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or marker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• For information regarding production reporting, contact the Office of Natural ResourcesRevenue (ONRR) at www.ONRR.gov.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production.

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion

Page 6 of 8Well: CWU 1538-25D

3/2/2012

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or marker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• For information regarding production reporting, contact the Office of Natural ResourcesRevenue (ONRR) at www.ONRR.gov.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production.

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion

Page 6 of 8Well: CWU 1538-25D

3/2/2012

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or marker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• For information regarding production reporting, contact the Office of Natural ResourcesRevenue (ONRR) at www.ONRR.gov.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production.

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion

Page 6 of 8Well: CWU 1538-25D

3/2/2012

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or marker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• For information regarding production reporting, contact the Office of Natural ResourcesRevenue (ONRR) at www.ONRR.gov.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production.

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion

Page 49: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 7 of 8Well: CWU 1538-25D

3/2/2012

the well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occursfirst. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workoverequipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Noncompliance and will begrounds for issuing a shut-in order until an acceptable manner for disposing of said water is providedand approved by this

Page 7 of 8Well: CWU 1538-25D

3/2/2012

the well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occursfirst. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workoverequipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Noncompliance and will begrounds for issuing a shut-in order until an acceptable manner for disposing of said water is providedand approved by this

Page 7 of 8Well: CWU 1538-25D

3/2/2012

the well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occursfirst. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workoverequipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Noncompliance and will begrounds for issuing a shut-in order until an acceptable manner for disposing of said water is providedand approved by this

Page 7 of 8Well: CWU 1538-25D

3/2/2012

the well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occursfirst. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workoverequipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Noncompliance and will begrounds for issuing a shut-in order until an acceptable manner for disposing of said water is providedand approved by this

Page 7 of 8Well: CWU 1538-25D

3/2/2012

the well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occursfirst. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workoverequipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Noncompliance and will begrounds for issuing a shut-in order until an acceptable manner for disposing of said water is providedand approved by this

Page 50: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Page 8 of 8Well: CWU 1538-25D

3/2/2012

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface

Page 8 of 8Well: CWU 1538-25D

3/2/2012

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface

Page 8 of 8Well: CWU 1538-25D

3/2/2012

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface

Page 8 of 8Well: CWU 1538-25D

3/2/2012

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface

Page 8 of 8Well: CWU 1538-25D

3/2/2012

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface

Page 51: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 09, 2012

 

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9 

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU0285A

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME: 

7.UNIT or CA AGREEMENT NAME: CHAPITA WELLS

1. TYPE OF WELL  Gas Well

8. WELL NAME and NUMBER: CWU 1538-25D

2. NAME OF OPERATOR: EOG Resources, Inc.

9. API NUMBER: 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER:  600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111  Ext

9. FIELD and POOL or WILDCAT: NATURAL BUTTES

4. LOCATION OF WELL  FOOTAGES AT SURFACE:     0673 FNL 0746 FWL   QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:     Qtr/Qtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S

COUNTY: UINTAH

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

 

    NOTICE OF INTENTApproximate date work will start:

7 /9 /2012

    SUBSEQUENT REPORTDate of Work Completion:

 

    SPUD REPORTDate of Spud:

 

    DRILLING REPORTReport Date:

 

    ACIDIZE      ALTER CASING      CASING REPAIR 

    CHANGE TO PREVIOUS PLANS      CHANGE TUBING      CHANGE WELL NAME 

    CHANGE WELL STATUS      COMMINGLE PRODUCING FORMATIONS      CONVERT WELL TYPE  

    DEEPEN      FRACTURE TREAT      NEW CONSTRUCTION 

    OPERATOR CHANGE      PLUG AND ABANDON      PLUG BACK 

    PRODUCTION START OR RESUME      RECLAMATION OF WELL SITE      RECOMPLETE DIFFERENT FORMATION 

    REPERFORATE CURRENT FORMATION      SIDETRACK TO REPAIR WELL      TEMPORARY ABANDON 

    TUBING REPAIR      VENT OR FLARE       WATER DISPOSAL 

    WATER SHUTOFF      SI TA STATUS EXTENSION      APD EXTENSION 

    WILDCAT WELL DETERMINATION      OTHER  OTHER: 

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referencedwell be extended for one year.

NAME (PLEASE PRINT) PHONE NUMBER  Vail Nazzaro 303 824-5590

TITLE Sr. Regulatory Assistant

SIGNATURE N/A

DATE 7 /9 /2012

July 11, 2012

Sundry Number: 27583 API Well Number: 43047511750000Sundry Number: 27583 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 11, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/9/2012

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 11, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/9/2012

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 11, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/9/2012

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 11, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/9/2012

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 11, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/9/2012

RECEIVED: Jul. 09,

Page 52: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 09, 2012

 

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43047511750000 

API:  43047511750000Well Name:  CWU 1538-25D

Location:  0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to:  EOG RESOURCES, INC.

Date Original Permit Issued:  8 /2 /2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement been updated?   Yes     No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location?    Yes     No

Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well?    Yes     No

Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location?    Yes     No

Has the approved source of water for drilling changed?    Yes     No

Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation?    Yes     No

Is bonding still in place, which covers this proposed well?    Yes     No

       Signature:  Vail Nazzaro Date: 7 /9 /2012

Title:  Sr. Regulatory Assistant Representing: EOG RESOURCES, INC.

Sundry Number: 27583 API Well Number: 43047511750000Sundry Number: 27583 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/9/2012Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/9/2012Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/9/2012Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/9/2012Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 09,

Sundry Number: 27583 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/9/2012Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 09,

Page 53: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 25, 2013

 

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9 

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU0285A

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME: 

7.UNIT or CA AGREEMENT NAME: CHAPITA WELLS

1. TYPE OF WELL  Gas Well

8. WELL NAME and NUMBER: CWU 1538-25D

2. NAME OF OPERATOR: EOG Resources, Inc.

9. API NUMBER: 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER:  600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111  Ext

9. FIELD and POOL or WILDCAT: NATURAL BUTTES

4. LOCATION OF WELL  FOOTAGES AT SURFACE:     0673 FNL 0746 FWL   QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:     Qtr/Qtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S

COUNTY: UINTAH

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

 

    NOTICE OF INTENTApproximate date work will start:

7 /25 /2013

    SUBSEQUENT REPORTDate of Work Completion:

 

    SPUD REPORTDate of Spud:

 

    DRILLING REPORTReport Date:

 

    ACIDIZE      ALTER CASING      CASING REPAIR 

    CHANGE TO PREVIOUS PLANS      CHANGE TUBING      CHANGE WELL NAME 

    CHANGE WELL STATUS      COMMINGLE PRODUCING FORMATIONS      CONVERT WELL TYPE  

    DEEPEN      FRACTURE TREAT      NEW CONSTRUCTION 

    OPERATOR CHANGE      PLUG AND ABANDON      PLUG BACK 

    PRODUCTION START OR RESUME      RECLAMATION OF WELL SITE      RECOMPLETE DIFFERENT FORMATION 

    REPERFORATE CURRENT FORMATION      SIDETRACK TO REPAIR WELL      TEMPORARY ABANDON 

    TUBING REPAIR      VENT OR FLARE       WATER DISPOSAL 

    WATER SHUTOFF      SI TA STATUS EXTENSION      APD EXTENSION 

    WILDCAT WELL DETERMINATION      OTHER  OTHER: 

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referencedwell be extended for one year.

NAME (PLEASE PRINT) PHONE NUMBER  Vail Nazzaro 303 824-5590

TITLE Sr. Regulatory Assistant

SIGNATURE N/A

DATE 7 /25 /2013

July 29, 2013

Sundry Number: 40485 API Well Number: 43047511750000Sundry Number: 40485 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/25/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 29, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/25/2013

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/25/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 29, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/25/2013

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/25/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 29, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/25/2013

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/25/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 29, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/25/2013

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG Resources, Inc. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/25/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Utah Division of

OFI, Gas and Mining

Date: July 29, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEVail Nazzaro 303 824-5590 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/25/2013

RECEIVED: Jul. 25,

Page 54: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 25, 2013

 

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43047511750000 

API:  43047511750000Well Name:  CWU 1538-25D

Location:  0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to:  EOG RESOURCES, INC.

Date Original Permit Issued:  8 /2 /2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement been updated?   Yes     No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location?    Yes     No

Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well?    Yes     No

Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location?    Yes     No

Has the approved source of water for drilling changed?    Yes     No

Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation?    Yes     No

Is bonding still in place, which covers this proposed well?    Yes     No

       Signature:  Vail Nazzaro Date: 7 /25 /2013

Title:  Sr. Regulatory Assistant Representing: EOG RESOURCES, INC.

Sundry Number: 40485 API Well Number: 43047511750000Sundry Number: 40485 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/25/2013Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/25/2013Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/25/2013Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/25/2013Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 25,

Sundry Number: 40485 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Vail Nazzaro Date: 7/25/2013Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 25,

Page 55: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 30, 2014

 

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9 

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU0285A

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME: 

7.UNIT or CA AGREEMENT NAME: CHAPITA WELLS

1. TYPE OF WELL  Gas Well

8. WELL NAME and NUMBER: CWU 1538-25D

2. NAME OF OPERATOR: EOG RESOURCES, INC.

9. API NUMBER: 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER:  600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111  Ext

9. FIELD and POOL or WILDCAT: NATURAL BUTTES

4. LOCATION OF WELL  FOOTAGES AT SURFACE:     0673 FNL 0746 FWL   QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:     Qtr/Qtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S

COUNTY: UINTAH

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

 

    NOTICE OF INTENTApproximate date work will start:

7 /30 /2014

    SUBSEQUENT REPORTDate of Work Completion:

 

    SPUD REPORTDate of Spud:

 

    DRILLING REPORTReport Date:

 

    ACIDIZE      ALTER CASING      CASING REPAIR 

    CHANGE TO PREVIOUS PLANS      CHANGE TUBING      CHANGE WELL NAME 

    CHANGE WELL STATUS      COMMINGLE PRODUCING FORMATIONS      CONVERT WELL TYPE  

    DEEPEN      FRACTURE TREAT      NEW CONSTRUCTION 

    OPERATOR CHANGE      PLUG AND ABANDON      PLUG BACK 

    PRODUCTION START OR RESUME      RECLAMATION OF WELL SITE      RECOMPLETE DIFFERENT FORMATION 

    REPERFORATE CURRENT FORMATION      SIDETRACK TO REPAIR WELL      TEMPORARY ABANDON 

    TUBING REPAIR      VENT OR FLARE       WATER DISPOSAL 

    WATER SHUTOFF      SI TA STATUS EXTENSION      APD EXTENSION 

    WILDCAT WELL DETERMINATION      OTHER  OTHER: 

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referencedwell be extended for one year.

NAME (PLEASE PRINT) PHONE NUMBER  Donna J Skinner 303 262-9467

TITLE Sr. Regulatory Assistant

SIGNATURE N/A

DATE 7 /30 /2014

July 31, 2014

Sundry Number: 53912 API Well Number: 43047511750000Sundry Number: 53912 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG RESOURCES, INC. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/30/2014CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Ukd1; BlyiRiikh‡of

OFI, Gas and Mining

Date:

NAME (PLEASE PRINT) PHONE NUMBER TITLEDonna J Skinner 303 262-9467 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/30/2014

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG RESOURCES, INC. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/30/2014CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Ukd1; BlyiRiikh‡of

OFI, Gas and Mining

Date:

NAME (PLEASE PRINT) PHONE NUMBER TITLEDonna J Skinner 303 262-9467 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/30/2014

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG RESOURCES, INC. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/30/2014CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Ukd1; BlyiRiikh‡of

OFI, Gas and Mining

Date:

NAME (PLEASE PRINT) PHONE NUMBER TITLEDonna J Skinner 303 262-9467 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/30/2014

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG RESOURCES, INC. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/30/2014CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Ukd1; BlyiRiikh‡of

OFI, Gas and Mining

Date:

NAME (PLEASE PRINT) PHONE NUMBER TITLEDonna J Skinner 303 262-9467 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/30/2014

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTUO285A

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. CHAPITAWELLS

1. TYPE OF WELL 8. WELL NAME and NUMBER:Gas Well CWU 1538-25D

2. NAME OF OPERATOR: 9. API NUMBER:EOG RESOURCES, INC. 43047511750000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:600 17th Street, Suite 1000 N , Denver, CO, 80202 435 781-9111 Ext NATURALBUTTES

4. LOCATION OF WELL COUNTY:FOOTAGESAT SURFACE: UINTAH

0673 FNL 0746 FWLQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWNW Section: 25 Township: 09.0S Range: 22.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

7/30/2014CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

EOG Resources, Inc. respectfully requests the APD for the referenced Approved by thewell be extended for one year. Ukd1; BlyiRiikh‡of

OFI, Gas and Mining

Date:

NAME (PLEASE PRINT) PHONE NUMBER TITLEDonna J Skinner 303 262-9467 Sr. Regulatory Assistant

SIGNATURE DATEN/A 7/30/2014

RECEIVED: Jul. 30,

Page 56: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

RECEIVED: Jul. 30, 2014

 

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43047511750000 

API:  43047511750000Well Name:  CWU 1538-25D

Location:  0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to:  EOG RESOURCES, INC.

Date Original Permit Issued:  8 /2 /2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement been updated?   Yes     No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location?    Yes     No

Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well?    Yes     No

Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location?    Yes     No

Has the approved source of water for drilling changed?    Yes     No

Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation?    Yes     No

Is bonding still in place, which covers this proposed well?    Yes     No

       Signature:  Donna J Skinner Date: 7 /30 /2014

Title:  Sr. Regulatory Assistant Representing: EOG RESOURCES, INC.

Sundry Number: 53912 API Well Number: 43047511750000Sundry Number: 53912 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Donna J Skinner Date: 7/30/2014Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Donna J Skinner Date: 7/30/2014Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Donna J Skinner Date: 7/30/2014Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Donna J Skinner Date: 7/30/2014Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 30,

Sundry Number: 53912 API Well Number: 43047511750000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry NoticesOTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43047511750000

API: 43047511750000Well Name: CWU 1538-25D

Location: 0673 FNL 0746 FWL QTR NWNW SEC 25 TWNP 090S RNG 220E MER SCompany Permit Issued to: EOG RESOURCES, INC.

Date Original Permit Issued: 8/2/2010

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Donna J Skinner Date: 7/30/2014Title: Sr. Regulatory Assistant Representing: EOGRESOURCES, INC.

RECEIVED: Jul. 30,

Page 57: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Form 3160-5 UNITED STATES FORM APPROVED (August 2007) ~ . :JP..£ ""

....::=:~ ~ . t:.u:t':Iia~·

DEPARTMENT OF THE INTERIOR OMB NO. 1004-0135

MAR 0 q 2014 Expires: Julv 31 2010 BUREAU OF LAND MANAGEMENT 5. Lease Serial No.

SUNDRY NOTICES AND REPORTS ON WEllS . UTU0285A Do not use this form for proposals to drill or to re-en!3L "A 6. If Indian, Allottee or Tribe Name abandoned well. Use form 3160-3 (APD) for such prop . :.: '" ~

SUBMIT IN TRIPLICATE - Other instructions on reverse side. 7. If Unit or CAiAgreement, Name and/or No. 892000905BF

I. Type of Well 8. Well Name and No.

o Oil Well Gil Gas Well 0 Other CWU 1538-250

2. Name of Operator Contact: DONNA J SKINNER 9. API Well No. EOG RESOURCES INC E-Mail: [email protected] 43-047-51175-00-X1

3a. Address 3b. Phone No. (include area code) 10. Field and Pool, or Exploratory

4.

600 17TH STREET, SUITE 1000N Ph: 303.262.9467 NATURAL BUTTES DENVER, CO 80202

Location of Well (Footage, Sec" T., R., M, or Survey Description) II. County or Parish, and State

Sec 25 T9S R22E NWNW 673FNL 746FWL UINTAH COUNTY, UT 40.012403 N Lat, 109.395089 W Lon

12, CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION

Gil Notice oflntent o Acidize

o Alter Casing o Subsequent Report o Casing Repair

o Final Abandonment Notice o Change Plans

o Convert to Injection

TYPE OF ACTION

o Deepen o Production (StartlResume)

o Fracture Treat o Reclamation

o New Construction o Recomplete

o Plug and Abandon o Temporarily Abandon

o Plug Back o Water Disposal

o Water Shut-Off

o Well Integrity

Gil Other Change to Original A PD

13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate duration thereof If the proposal is to deepen directionally or recomplete horizontally, give subsurface locations and measured and true vertical depths of all pertinent markers and zones. Attach the Bond under which the work will be performed or provide the Bond No. on file with BLMlBIA. Required subsequent reports shall be filed within 30 days following completion of the involved operations. If the operation results in a multiple completion or recompletion in a new interval, a Form 3160-4 shall be filed once testing has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have be~rrCUlfPletcd, Mid lite epel'llteF-ftas determmed that the site IS ready for fmal mspectlon.) . . : ERI'IAL FIELD OFFICE

EOG Resources, Inc. respectfully requests a two year extension for the refe,aECeY.ED::1\IG. dl Iv / 7 /f~ _" .

OCT 2 0 2014 ;::OL. ----DIV. OF OIL, GAS & MINING

CONUITIONS Of APPROVAl ATTACHEIJ

,., ';)._------C1. .. ____ _

14. I hereby certify that the foregoing is true and correct. Electronic Submission #237570 verlfl by the BlM Well Information System

For EOG RESOURCES NC, sent to the Vernal Committed to AFMSS for processing by lE LIE BUHLER on 0310512014 (14lBB4779SE)

Name (PrintedlTyped) DONNA J SKINNER Title SR. REGULATORY ASSISTANT OCT 20 2014

Signature

_Ap![.Ovc:! By_

Conditions of appr

DIV. OF Oil, GAS & MINING (Electronic Submission) Date 03/03/2014

THIS SPACE FOR FEDERAL OR STATE OFFICE USE

Title

Office

Assfstant Field Manager lands & M'

VERNAL FIELD OFFICE

gel 03 2014

Title 18 U.S.c. Section 1001 and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any department or agency of the United States any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction.

** BlM REVISED ** BlM REVISED ** BlM REVISED ** BlM REVISED ** BlM REVISED **

3st2007) UNITED STATES AECElVED FORM APPROVED

DEPARTMENT OF THE INTERIdR OMB NO. 1004-0135

BUREAU OF LAND MANAGEMENT MAÑÔ$ Expires: July 31, 20105. Lease Serial No.

SUNDRY NOTICES AND REPORTS ON WELLS UTUO285ADo not use this form for proposals to drill or to re-en

abandoned well. Use form 3160-3 (APD) for such prop 6. If Indian, Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on reverse side. IgU2nt00r9C eement, Name and/or No.

1. Type of Well 8. Well Name and No.

O Oil Well B Gas Well O Other CWU 1538-25D

2. Name of Operator Contact: DONNAJ SKINNER 9. API Well No.EOG RESOURCES INC E-Mail: [email protected] 43-047-51175-00-X1

3a Address 3b. Phone No. (include area code) 10. Field and Pool, or Exploratory600 17TH STREET, SUITE 1000N Ph: 303.262.9467 NATURALBUTTESDENVER, CO 80202

4. Location of Well (Footage, Sec., T., R., M., or Survey Description) 11. County or Parish, and State

Sec 25 T9S R22E NWNW673FNL 746FWL UINTAHCOUNTY, UT40.012403 N Lat, 109.395089 W Lon

12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

O Acidize O Deepen O Production (Start/Resume) O Water Shut-Offg Notice of Intent

0 Alter casing 0 Fracture Treat O Reclamation 0 Well IntegrityO Subsequent Report O Casing Repair O New Construction O Recomplete Other

0 Final Abandonment Notice O Change Plans O Plug and Abandon 0 Temporarily Abandon ange to Original A

O Convert to Injection 0 Plug Back O Water Disposal

13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate durationthereofIf the proposal is to deepen directionallyor recomplete horizontally,give subsurface locations and measured and true vertical depths of all pertinent markers and zones.Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/BIA. Required subsequent reports shall be filed within 30 daysfollowingcompletion of the involvedoperations. If the operation results in a multiple completion or recompletion in a new interval,a Form 3160-4 shall be filed oncetesting has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have Leca cumple sJ, and Ja, ops a hûadeterminedthat the site is ready for final inspection.) ERNALFIELDOFFICEEOG Resources, Inc. respectfully requests a twoyear extension for the refeg.ggED

OCT20 2014

DIV.0FOIL,GAS&MININGSCONulfl0NSOFAPPROVALATTACHED

14. I hereby certify that the foregoing is true and correct.Electronic Submission #237570 verlfli i by the BLM Well Information System

For EOG RESOURCES NC, sent to the VernalCommitted to AFMSS for processing by LE- LIE BUHLER on 03/05/2014 (14LBB4779SE)

Name(Printed/Typed) DONNAJ SKINNER Title SR. REGULATORYASSISTANT

DIV.0FOIL,GAS&MININGSignature (Electronic Submission) Date 03/03/2014

THIS SPACE FOR FEDERAL OR STATE OFFICE USE

Apgove_By__

Title Lands &MineralRannum e

Conditions of appr any re . Approval of this notice does not warrant or a tr•Das a a t-i r•s a n a rcertify that the ap ic t ho s legal or equitable title to those rights in the subject lease VEnlilAL FI ELU U l Cwhich would entitle the plicant to conduct operations thereon. Office

Title 18 U.S.C. Section 1001and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any departmentor agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within itsjurisdiction.

** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED

3st2007) UNITED STATES AECElVED FORM APPROVED

DEPARTMENT OF THE INTERIdR OMB NO. 1004-0135

BUREAU OF LAND MANAGEMENT MAÑÔ$ Expires: July 31, 20105. Lease Serial No.

SUNDRY NOTICES AND REPORTS ON WELLS UTUO285ADo not use this form for proposals to drill or to re-en

abandoned well. Use form 3160-3 (APD) for such prop 6. If Indian, Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on reverse side. IgU2nt00r9C eement, Name and/or No.

1. Type of Well 8. Well Name and No.

O Oil Well B Gas Well O Other CWU 1538-25D

2. Name of Operator Contact: DONNAJ SKINNER 9. API Well No.EOG RESOURCES INC E-Mail: [email protected] 43-047-51175-00-X1

3a Address 3b. Phone No. (include area code) 10. Field and Pool, or Exploratory600 17TH STREET, SUITE 1000N Ph: 303.262.9467 NATURALBUTTESDENVER, CO 80202

4. Location of Well (Footage, Sec., T., R., M., or Survey Description) 11. County or Parish, and State

Sec 25 T9S R22E NWNW673FNL 746FWL UINTAHCOUNTY, UT40.012403 N Lat, 109.395089 W Lon

12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

O Acidize O Deepen O Production (Start/Resume) O Water Shut-Offg Notice of Intent

0 Alter casing 0 Fracture Treat O Reclamation 0 Well IntegrityO Subsequent Report O Casing Repair O New Construction O Recomplete Other

0 Final Abandonment Notice O Change Plans O Plug and Abandon 0 Temporarily Abandon ange to Original A

O Convert to Injection 0 Plug Back O Water Disposal

13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate durationthereofIf the proposal is to deepen directionallyor recomplete horizontally,give subsurface locations and measured and true vertical depths of all pertinent markers and zones.Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/BIA. Required subsequent reports shall be filed within 30 daysfollowingcompletion of the involvedoperations. If the operation results in a multiple completion or recompletion in a new interval,a Form 3160-4 shall be filed oncetesting has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have Leca cumple sJ, and Ja, ops a hûadeterminedthat the site is ready for final inspection.) ERNALFIELDOFFICEEOG Resources, Inc. respectfully requests a twoyear extension for the refeg.ggED

OCT20 2014

DIV.0FOIL,GAS&MININGSCONulfl0NSOFAPPROVALATTACHED

14. I hereby certify that the foregoing is true and correct.Electronic Submission #237570 verlfli i by the BLM Well Information System

For EOG RESOURCES NC, sent to the VernalCommitted to AFMSS for processing by LE- LIE BUHLER on 03/05/2014 (14LBB4779SE)

Name(Printed/Typed) DONNAJ SKINNER Title SR. REGULATORYASSISTANT

DIV.0FOIL,GAS&MININGSignature (Electronic Submission) Date 03/03/2014

THIS SPACE FOR FEDERAL OR STATE OFFICE USE

Apgove_By__

Title Lands &MineralRannum e

Conditions of appr any re . Approval of this notice does not warrant or a tr•Das a a t-i r•s a n a rcertify that the ap ic t ho s legal or equitable title to those rights in the subject lease VEnlilAL FI ELU U l Cwhich would entitle the plicant to conduct operations thereon. Office

Title 18 U.S.C. Section 1001and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any departmentor agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within itsjurisdiction.

** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED

3st2007) UNITED STATES AECElVED FORM APPROVED

DEPARTMENT OF THE INTERIdR OMB NO. 1004-0135

BUREAU OF LAND MANAGEMENT MAÑÔ$ Expires: July 31, 20105. Lease Serial No.

SUNDRY NOTICES AND REPORTS ON WELLS UTUO285ADo not use this form for proposals to drill or to re-en

abandoned well. Use form 3160-3 (APD) for such prop 6. If Indian, Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on reverse side. IgU2nt00r9C eement, Name and/or No.

1. Type of Well 8. Well Name and No.

O Oil Well B Gas Well O Other CWU 1538-25D

2. Name of Operator Contact: DONNAJ SKINNER 9. API Well No.EOG RESOURCES INC E-Mail: [email protected] 43-047-51175-00-X1

3a Address 3b. Phone No. (include area code) 10. Field and Pool, or Exploratory600 17TH STREET, SUITE 1000N Ph: 303.262.9467 NATURALBUTTESDENVER, CO 80202

4. Location of Well (Footage, Sec., T., R., M., or Survey Description) 11. County or Parish, and State

Sec 25 T9S R22E NWNW673FNL 746FWL UINTAHCOUNTY, UT40.012403 N Lat, 109.395089 W Lon

12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

O Acidize O Deepen O Production (Start/Resume) O Water Shut-Offg Notice of Intent

0 Alter casing 0 Fracture Treat O Reclamation 0 Well IntegrityO Subsequent Report O Casing Repair O New Construction O Recomplete Other

0 Final Abandonment Notice O Change Plans O Plug and Abandon 0 Temporarily Abandon ange to Original A

O Convert to Injection 0 Plug Back O Water Disposal

13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate durationthereofIf the proposal is to deepen directionallyor recomplete horizontally,give subsurface locations and measured and true vertical depths of all pertinent markers and zones.Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/BIA. Required subsequent reports shall be filed within 30 daysfollowingcompletion of the involvedoperations. If the operation results in a multiple completion or recompletion in a new interval,a Form 3160-4 shall be filed oncetesting has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have Leca cumple sJ, and Ja, ops a hûadeterminedthat the site is ready for final inspection.) ERNALFIELDOFFICEEOG Resources, Inc. respectfully requests a twoyear extension for the refeg.ggED

OCT20 2014

DIV.0FOIL,GAS&MININGSCONulfl0NSOFAPPROVALATTACHED

14. I hereby certify that the foregoing is true and correct.Electronic Submission #237570 verlfli i by the BLM Well Information System

For EOG RESOURCES NC, sent to the VernalCommitted to AFMSS for processing by LE- LIE BUHLER on 03/05/2014 (14LBB4779SE)

Name(Printed/Typed) DONNAJ SKINNER Title SR. REGULATORYASSISTANT

DIV.0FOIL,GAS&MININGSignature (Electronic Submission) Date 03/03/2014

THIS SPACE FOR FEDERAL OR STATE OFFICE USE

Apgove_By__

Title Lands &MineralRannum e

Conditions of appr any re . Approval of this notice does not warrant or a tr•Das a a t-i r•s a n a rcertify that the ap ic t ho s legal or equitable title to those rights in the subject lease VEnlilAL FI ELU U l Cwhich would entitle the plicant to conduct operations thereon. Office

Title 18 U.S.C. Section 1001and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any departmentor agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within itsjurisdiction.

** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED

3st2007) UNITED STATES AECElVED FORM APPROVED

DEPARTMENT OF THE INTERIdR OMB NO. 1004-0135

BUREAU OF LAND MANAGEMENT MAÑÔ$ Expires: July 31, 20105. Lease Serial No.

SUNDRY NOTICES AND REPORTS ON WELLS UTUO285ADo not use this form for proposals to drill or to re-en

abandoned well. Use form 3160-3 (APD) for such prop 6. If Indian, Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on reverse side. IgU2nt00r9C eement, Name and/or No.

1. Type of Well 8. Well Name and No.

O Oil Well B Gas Well O Other CWU 1538-25D

2. Name of Operator Contact: DONNAJ SKINNER 9. API Well No.EOG RESOURCES INC E-Mail: [email protected] 43-047-51175-00-X1

3a Address 3b. Phone No. (include area code) 10. Field and Pool, or Exploratory600 17TH STREET, SUITE 1000N Ph: 303.262.9467 NATURALBUTTESDENVER, CO 80202

4. Location of Well (Footage, Sec., T., R., M., or Survey Description) 11. County or Parish, and State

Sec 25 T9S R22E NWNW673FNL 746FWL UINTAHCOUNTY, UT40.012403 N Lat, 109.395089 W Lon

12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

O Acidize O Deepen O Production (Start/Resume) O Water Shut-Offg Notice of Intent

0 Alter casing 0 Fracture Treat O Reclamation 0 Well IntegrityO Subsequent Report O Casing Repair O New Construction O Recomplete Other

0 Final Abandonment Notice O Change Plans O Plug and Abandon 0 Temporarily Abandon ange to Original A

O Convert to Injection 0 Plug Back O Water Disposal

13. Describe Proposed or Completed Operation (clearly state all pertinent details, including estimated starting date of any proposed work and approximate durationthereofIf the proposal is to deepen directionallyor recomplete horizontally,give subsurface locations and measured and true vertical depths of all pertinent markers and zones.Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/BIA. Required subsequent reports shall be filed within 30 daysfollowingcompletion of the involvedoperations. If the operation results in a multiple completion or recompletion in a new interval,a Form 3160-4 shall be filed oncetesting has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have Leca cumple sJ, and Ja, ops a hûadeterminedthat the site is ready for final inspection.) ERNALFIELDOFFICEEOG Resources, Inc. respectfully requests a twoyear extension for the refeg.ggED

OCT20 2014

DIV.0FOIL,GAS&MININGSCONulfl0NSOFAPPROVALATTACHED

14. I hereby certify that the foregoing is true and correct.Electronic Submission #237570 verlfli i by the BLM Well Information System

For EOG RESOURCES NC, sent to the VernalCommitted to AFMSS for processing by LE- LIE BUHLER on 03/05/2014 (14LBB4779SE)

Name(Printed/Typed) DONNAJ SKINNER Title SR. REGULATORYASSISTANT

DIV.0FOIL,GAS&MININGSignature (Electronic Submission) Date 03/03/2014

THIS SPACE FOR FEDERAL OR STATE OFFICE USE

Apgove_By__

Title Lands &MineralRannum e

Conditions of appr any re . Approval of this notice does not warrant or a tr•Das a a t-i r•s a n a rcertify that the ap ic t ho s legal or equitable title to those rights in the subject lease VEnlilAL FI ELU U l Cwhich would entitle the plicant to conduct operations thereon. Office

Title 18 U.S.C. Section 1001and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any departmentor agency of the UnitedStates any false, fictitious or fraudulent statements or representations as to any matter within itsjurisdiction.

** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED

Page 58: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Revisions to Operator-Submltted EC Data for Sundry Notice #237570

Sundry Type:

Lease:

Agreement:

Operator:

Admin Contact:

Operator Submitted

FAC NOI

UTU0285A

CHAPITA WELLS UN

EOG RESOURCES. INC. 600 17TH STREET SUITE 1OO0N DENVER. CO 80202 Ph: 303-572-9000

DONNA J SKINNER SR. REGULATORY ASSISTANT E-Mail: [email protected]

Ph: 303-262-9467

Tech Contact: DONNA J SKINNER

Location: State: County:

Field/Pool:

WelllFacility:

SR. REGULATORY ASSISTANT E-Mail: [email protected]

Ph: 303-262-9467

UT UINTAH

NATURAL BUTTES

CWU 1538-250 Sec 25 T9S R22E Mer SLB NWNW 673FNL 746FWL 40.012400 N Lat. 109.395090 W Lon

BlM Revised (AFMSS)

APDCH NOI

UTU0285A

892oo0905BF (UTU63013BF)

EOG RESOURCES INC 600 17TH STREET. SUITE 1000N DENVER. CO 80202 Ph: 303-572-9000

DONNA J SKINNER SR. REGULATORY ASSISTANT E-Mail: [email protected]

Ph: 303.262.9467

DONNA J SKINNER SR. REGULATORY ASSISTANT E-Mail: [email protected]

Ph: 303.262.9467

UT UINTAH

NATURAL BUTTES

CWU 1538-250 Sec 25 T9S R22E NWNW 673FNL 746FWL 40.012403 N Lat. 109.395089 W Lon

Revisions to Operator-Submitted EC Data for Sundry Notice #237570

Operator Submitted BLM Revised (AFMSS)

Sundry Type: FAC APDCHNOI NOI

Lease: UTUO285A UTUO285A

Agreement: CHAPITAWELLS UN 892000905BF (UTU63013BF)

Operator: EOG RESOURCES, INC. EOG RESOURCES INC600 17TH STREET SUITE 1000N 600 17TH STREET, SUITE 1000NDENVER, CO 80202 DENVER, CO 80202Ph: 303-572-9000 Ph: 303-572-9000

Admin Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Tech Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Location:State: UT UTCounty: UINTAH . UINTAH

Field/Pool: NATURALBUTTES NATURALBUTTES

Well/Facility: CWU 1538-25D CWU 1538-25DSec 25 T9S R22E Mer SLB NWNW 673FNL 746FWL Sec 25 T9S R22E NWNW673FNL 746FWL40.012400 N Lat, 109.395090 W Lon 40.012403 N Lat, 109.395089 W

Revisions to Operator-Submitted EC Data for Sundry Notice #237570

Operator Submitted BLM Revised (AFMSS)

Sundry Type: FAC APDCHNOI NOI

Lease: UTUO285A UTUO285A

Agreement: CHAPITAWELLS UN 892000905BF (UTU63013BF)

Operator: EOG RESOURCES, INC. EOG RESOURCES INC600 17TH STREET SUITE 1000N 600 17TH STREET, SUITE 1000NDENVER, CO 80202 DENVER, CO 80202Ph: 303-572-9000 Ph: 303-572-9000

Admin Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Tech Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Location:State: UT UTCounty: UINTAH . UINTAH

Field/Pool: NATURALBUTTES NATURALBUTTES

Well/Facility: CWU 1538-25D CWU 1538-25DSec 25 T9S R22E Mer SLB NWNW 673FNL 746FWL Sec 25 T9S R22E NWNW673FNL 746FWL40.012400 N Lat, 109.395090 W Lon 40.012403 N Lat, 109.395089 W

Revisions to Operator-Submitted EC Data for Sundry Notice #237570

Operator Submitted BLM Revised (AFMSS)

Sundry Type: FAC APDCHNOI NOI

Lease: UTUO285A UTUO285A

Agreement: CHAPITAWELLS UN 892000905BF (UTU63013BF)

Operator: EOG RESOURCES, INC. EOG RESOURCES INC600 17TH STREET SUITE 1000N 600 17TH STREET, SUITE 1000NDENVER, CO 80202 DENVER, CO 80202Ph: 303-572-9000 Ph: 303-572-9000

Admin Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Tech Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Location:State: UT UTCounty: UINTAH . UINTAH

Field/Pool: NATURALBUTTES NATURALBUTTES

Well/Facility: CWU 1538-25D CWU 1538-25DSec 25 T9S R22E Mer SLB NWNW 673FNL 746FWL Sec 25 T9S R22E NWNW673FNL 746FWL40.012400 N Lat, 109.395090 W Lon 40.012403 N Lat, 109.395089 W

Revisions to Operator-Submitted EC Data for Sundry Notice #237570

Operator Submitted BLM Revised (AFMSS)

Sundry Type: FAC APDCHNOI NOI

Lease: UTUO285A UTUO285A

Agreement: CHAPITAWELLS UN 892000905BF (UTU63013BF)

Operator: EOG RESOURCES, INC. EOG RESOURCES INC600 17TH STREET SUITE 1000N 600 17TH STREET, SUITE 1000NDENVER, CO 80202 DENVER, CO 80202Ph: 303-572-9000 Ph: 303-572-9000

Admin Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Tech Contact: DONNAJ SKINNER DONNAJ SKINNERSR. REGULATORY ASSISTANT SR. REGULATORYASSISTANTE-Mail: [email protected] E-Mail: [email protected]

Ph: 303-262-9467 Ph: 303.262.9467

Location:State: UT UTCounty: UINTAH . UINTAH

Field/Pool: NATURALBUTTES NATURALBUTTES

Well/Facility: CWU 1538-25D CWU 1538-25DSec 25 T9S R22E Mer SLB NWNW 673FNL 746FWL Sec 25 T9S R22E NWNW673FNL 746FWL40.012400 N Lat, 109.395090 W Lon 40.012403 N Lat, 109.395089 W

Page 59: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

Lease: Well:

CONDITIONS OF APPROVAL

UTU-0285A

EOG Resources Inc Notice of Intent APD Extension

Location: Chapita Wells Unit 1538-25D NWNW Sec 25 T9S-R22E

An extension for the referenced APD is granted with the following conditions:

1. The APD extension shall expire on 3/8/16

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Michael Riches of this office at (435) 781-4438

CONDITIONS OF APPROVAL

EOG Resources IncNotice of IntentAPD Extension

Lease: UTU-0285AWell: Chapita Wells Unit 1538-25DLocation: NWNW Sec 25 T9S-R22E

An extension for the referenced APD is granted with the following conditions:

1. The APD extension shall expire on 3/8/16

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Michael Riches of thisoffice at (435)

CONDITIONS OF APPROVAL

EOG Resources IncNotice of IntentAPD Extension

Lease: UTU-0285AWell: Chapita Wells Unit 1538-25DLocation: NWNW Sec 25 T9S-R22E

An extension for the referenced APD is granted with the following conditions:

1. The APD extension shall expire on 3/8/16

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Michael Riches of thisoffice at (435)

CONDITIONS OF APPROVAL

EOG Resources IncNotice of IntentAPD Extension

Lease: UTU-0285AWell: Chapita Wells Unit 1538-25DLocation: NWNW Sec 25 T9S-R22E

An extension for the referenced APD is granted with the following conditions:

1. The APD extension shall expire on 3/8/16

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Michael Riches of thisoffice at (435)

CONDITIONS OF APPROVAL

EOG Resources IncNotice of IntentAPD Extension

Lease: UTU-0285AWell: Chapita Wells Unit 1538-25DLocation: NWNW Sec 25 T9S-R22E

An extension for the referenced APD is granted with the following conditions:

1. The APD extension shall expire on 3/8/16

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Michael Riches of thisoffice at (435)

Page 60: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

, State of UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

GARY R.HERBERT Executive Director

covernor Division of Oil, Gas and MiningSPENCER J. COX JOHN R. BAZALieutenant Govemor Division Director

September 10, 2015

EOG Resources, Inc.600 17th Street, Suite 1000NDenver, CO 80202

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed find the list of APDs that is being rescinded. No drilling activityat these locations has been reported to the division. Therefore, approval to drillthese wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval prior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

uvironmental Scientist

cc: Well FileBureau of Land Management, Vernal

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801telephone (801) 538-5340 • facsimile (801) 359-3940 • TTY (801) 538-7458 • www.ogm.utah.gov

OIL, GAS &

, State of UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

GARY R.HERBERT Executive Director

covernor Division of Oil, Gas and MiningSPENCER J. COX JOHN R. BAZALieutenant Govemor Division Director

September 10, 2015

EOG Resources, Inc.600 17th Street, Suite 1000NDenver, CO 80202

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed find the list of APDs that is being rescinded. No drilling activityat these locations has been reported to the division. Therefore, approval to drillthese wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval prior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

uvironmental Scientist

cc: Well FileBureau of Land Management, Vernal

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801telephone (801) 538-5340 • facsimile (801) 359-3940 • TTY (801) 538-7458 • www.ogm.utah.gov

OIL, GAS &

, State of UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

GARY R.HERBERT Executive Director

covernor Division of Oil, Gas and MiningSPENCER J. COX JOHN R. BAZALieutenant Govemor Division Director

September 10, 2015

EOG Resources, Inc.600 17th Street, Suite 1000NDenver, CO 80202

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed find the list of APDs that is being rescinded. No drilling activityat these locations has been reported to the division. Therefore, approval to drillthese wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval prior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

uvironmental Scientist

cc: Well FileBureau of Land Management, Vernal

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801telephone (801) 538-5340 • facsimile (801) 359-3940 • TTY (801) 538-7458 • www.ogm.utah.gov

OIL, GAS &

Page 61: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

43-047-36955 SCU 87-2043-047-37135 14Cheq>ita293-2843-047-50470 CWU 1455-2143-047-50543 CWU 1447-1943-047-50540 CWU 1443-1943-047-50541 CWU 1444-1943-047-50544 CWU 1437-1943-047-50556 CWU 1421-3443-047-50559 SCW 30-0343-047-50561 SWONV28-0343-047-50582 SCW 26-0343-047-50586 CNVIJ1394-0343-047-50587 CWU 1404-3443-047-50588 CWU 1439-1943-047-50614 CWU 1452-2943-047-50615 CWU 1454-2943-047-50617 CWU 1457-2943-047-50618 CSASJ1458-2943-047-50622 CWU 1445-1943-047-50666 EX]114-0543-047-50667 HOSS 124-3443-047-50676 (19VIJ1469-3443-047-50677 EC 111-0543-047-51121 IICISS 52-2943-047-51173 CWU 1536-25D43-047-51174 CWU 1537-25D43-047-51175 CWU 1538-25D43-047-51176 CWU 1539-25D43-047-51177 CWU 1540-25D

43-047-36955 SCU 87-2043-047-37135 14Cheq>ita293-2843-047-50470 CWU 1455-2143-047-50543 CWU 1447-1943-047-50540 CWU 1443-1943-047-50541 CWU 1444-1943-047-50544 CWU 1437-1943-047-50556 CWU 1421-3443-047-50559 SCW 30-0343-047-50561 SWONV28-0343-047-50582 SCW 26-0343-047-50586 CNVIJ1394-0343-047-50587 CWU 1404-3443-047-50588 CWU 1439-1943-047-50614 CWU 1452-2943-047-50615 CWU 1454-2943-047-50617 CWU 1457-2943-047-50618 CSASJ1458-2943-047-50622 CWU 1445-1943-047-50666 EX]114-0543-047-50667 HOSS 124-3443-047-50676 (19VIJ1469-3443-047-50677 EC 111-0543-047-51121 IICISS 52-2943-047-51173 CWU 1536-25D43-047-51174 CWU 1537-25D43-047-51175 CWU 1538-25D43-047-51176 CWU 1539-25D43-047-51177 CWU 1540-25D

43-047-36955 SCU 87-2043-047-37135 14Cheq>ita293-2843-047-50470 CWU 1455-2143-047-50543 CWU 1447-1943-047-50540 CWU 1443-1943-047-50541 CWU 1444-1943-047-50544 CWU 1437-1943-047-50556 CWU 1421-3443-047-50559 SCW 30-0343-047-50561 SWONV28-0343-047-50582 SCW 26-0343-047-50586 CNVIJ1394-0343-047-50587 CWU 1404-3443-047-50588 CWU 1439-1943-047-50614 CWU 1452-2943-047-50615 CWU 1454-2943-047-50617 CWU 1457-2943-047-50618 CSASJ1458-2943-047-50622 CWU 1445-1943-047-50666 EX]114-0543-047-50667 HOSS 124-3443-047-50676 (19VIJ1469-3443-047-50677 EC 111-0543-047-51121 IICISS 52-2943-047-51173 CWU 1536-25D43-047-51174 CWU 1537-25D43-047-51175 CWU 1538-25D43-047-51176 CWU 1539-25D43-047-51177 CWU 1540-25D

Page 62: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

State 0. Utah DEPARTMENT OF NATURAL RESOURCES

GARY R. HERBERT Governor

MICHAEL R. STYLER Executive Director

Division of Oil, Gas and Mining JOHN R. BAZA SPENCER J. COX

Lieutenant Governor Division Director

EOG Resources, Inc. 600 17th Street, Suite 1000 N Denver, CO 80202

September 10, 2015

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed fmd the list of APDs that is being rescinded. No drilling activity at these locations has been reported to the division. Therefore, approval to drill these wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval prior to the commencement of any future work on the subject location.

If any previously unreported operations have been performed on this well location, it is imperative that you notify the Division immediately.

Sincerely,

G-t.JI.dL (l...{<J"'-.--lana ason nvironmental Scientist

cc: Well File Bureau of Land Management, Vernal

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801 telephone (801) 538-5340. facsimile (801) 359-3940. TTY (801) 538-7458. www.ogm.utah.gov

OIL, GAS So. MIN ING

State or UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

GARY R. HERBERT Executive Director

Governor Division of Oil, Gas and MiningSPENCER J. COX JOHN R. BAZALieutenant Govemor Division Director

September 10, 2015

EOG Resources, Inc.600 17th Street, Suite 1000NDenver, CO 80202

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed find the list of APDs that is being rescinded. No drilling activityat these locations has been reported to the division. Therefore, approval to drillthese wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval vrior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

iana asonnvironmental Scientist

cc: Well FileBureau of Land Management, Vernal

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801telephone (801) 538-5340 •facsimile (801) 359-3940 •TTY (801) 538-7458 • www ogm.utah.gov

OIL, GAS &

State or UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

GARY R. HERBERT Executive Director

Governor Division of Oil, Gas and MiningSPENCER J. COX JOHN R. BAZALieutenant Govemor Division Director

September 10, 2015

EOG Resources, Inc.600 17th Street, Suite 1000NDenver, CO 80202

Re: APDs Rescinded for EOG Resources Inc., Uintah County

Ladies and Gentlemen:

Enclosed find the list of APDs that is being rescinded. No drilling activityat these locations has been reported to the division. Therefore, approval to drillthese wells is hereby rescinded as of September 10, 2015.

A new APD must be filed with this office for approval vrior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

iana asonnvironmental Scientist

cc: Well FileBureau of Land Management, Vernal

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801telephone (801) 538-5340 •facsimile (801) 359-3940 •TTY (801) 538-7458 • www ogm.utah.gov

OIL, GAS &

Page 63: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

43-047-36955 43-047-37135 43-047-50470 43-047-50543 43-047-50540 43-047-50541 43-047-50544 43-047-50556 43-047-50559 43-047-50561 43-047-50582 43-047-50586 43-047-50587 43-047-50588 43-047-50614 43-047-50615 43-047-50617 43-047-50618 43-047-50622 43-047-50666 43-047-50667 43-047-50676 43-047-50677 43-047-51121 43-047-51173 43-047-51174 43-047-51175 43-047-51176 43-047-51177

SCU 87-20 N Chapita 293-28 CWU 1455-21 CWU 1447-19 CWU 1443-19 CWU 1444-19 CWU 1437-19 CWU 1421-34 SCW30-03 SCW28-03 SCW26-03 CWU 1394-03 CWU 1404-34 CWU 1439-19 CWU 1452-29 CWU 1454-29 CWU 1457-29 CWU 1458-29 CWU 1445-19 EC 114-05 HOSS 124-34 CWU 1469-34 EC 111-05 HOSS 52-29 CWU 1536-25D CWU 1537-25D CWU 1538-25D CWU 1539-25D CWU 1540-25D

43-047-36955 SCU 87-2043-047-37135 N Chapita 293-2843-047-50470 CWU 1455-2143-047-50543 CSA1J1447-1943-047-50540 CWU 1443-1943-047-50541 CWU 1444-1943-047-50544 CSARJ1437-1943-047-50556 CWU 1421-3443-047-50559 SCIVV30-0343-047-50561 SC'n'28-0343-047-50582 SCiV26-0343-047-50586 CSAll 1394-0343-047-50587 CWU 1404-3443-047-50588 CWU 1439-1943-047-50614 CDA1]1452-2943-047-50615 CWU 1454-2943-047-50617 CWU 1457-2943-047-50618 CWU 1458-2943-047-50622 CWU 1445-1943-047-50666 EC 114-0543-047-50667 HOSS 124-3443-047-50676 CWU 1469-3443-047-50677 EX]111-0543-047-51121 HOSS 52-2943-047-51173 CWU 1536-25D43-047-51174 CWU 1537-25D43-047-51175 CSAll 1538-25D43-047-51176 CWU 1539-25D43-047-51177 CWU

43-047-36955 SCU 87-2043-047-37135 N Chapita 293-2843-047-50470 CWU 1455-2143-047-50543 CSA1J1447-1943-047-50540 CWU 1443-1943-047-50541 CWU 1444-1943-047-50544 CSARJ1437-1943-047-50556 CWU 1421-3443-047-50559 SCIVV30-0343-047-50561 SC'n'28-0343-047-50582 SCiV26-0343-047-50586 CSAll 1394-0343-047-50587 CWU 1404-3443-047-50588 CWU 1439-1943-047-50614 CDA1]1452-2943-047-50615 CWU 1454-2943-047-50617 CWU 1457-2943-047-50618 CWU 1458-2943-047-50622 CWU 1445-1943-047-50666 EC 114-0543-047-50667 HOSS 124-3443-047-50676 CWU 1469-3443-047-50677 EX]111-0543-047-51121 HOSS 52-2943-047-51173 CWU 1536-25D43-047-51174 CWU 1537-25D43-047-51175 CSAll 1538-25D43-047-51176 CWU 1539-25D43-047-51177 CWU

Page 64: API Well No: 43047511750000 Received: 7/21/2010fWellW ... · api number assigned 43047511750000 permit manager approval form 3 amended report api well no: 43047511750000 received:

, ? - -, ---

'0. -, -

, ~ -

IN REPLY REFER TO: 3160 (UTG011)

United States Department of the Interior

BUREAU OF LAND MANAGEMENT Green River District Vernal Field Office 170 South 500 East Vernal, UT 84078

http://www.blm.gov/utlstlenlfo/vernal.html

MAR 25 2016 RECE\VED APR 04 20\S

Kaylene Gardner EOG Resources Inc. 600 17th Street, Suite 1000 N Denver, CO 80202

. DlV.OfOll,GAS&MINING

Dear Kaylene:

The referenced Applications for Permit to Drill (APD) have expired. According to our records, no known activity has transpired at the approved location. In view of the foregoing, this office is notifying you that the approval of the referenced applications has expired. If you intend to drill at these locations in the future, a new Application for Permit to Drill must be submitted.

4?-{)\-i Lease Well Aliquot Sec., T., R. Approved Expiration Extension Exp. UTU-0285A 1530-250 NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 1511 UTU-0285A 1531-250 NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 &;~D;

UTU-0285A 1532-250 NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 SJO UTU-0285A 1533-250 NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 '5"JD UTU-0285A 1534-250 NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 '5"ID UTU-0285A 1535-250 NWNW Sec. 25-T9S-R22E 3/9/2012 3/9/2014 3/9/2016 51.~ UTU-0285A 1536-250 NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 C} Jl., 1-:i UTU-0285A 1537-250 NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 e.:..t 17~ UTU-0285A 1538-250 NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 ~H1' UTU-0285A 1539-250 NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 UTU-0285A 1540-250 NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016

This office requires a letter confirming that no surface disturbance has been made for these drill sites. Any surface disturbance associated with the approved location of these wells is to be rehabilitated. A schedule for this rehabilitation must be submitted to this office.

Your cooperation in this matter is appreciated. If you have any questions regarding this matter, please contact Jeanne E. Newman at (435) 781-4488.

Sincerely,

Kenczka Assistant Field Manager Lands & Mineral Resources

t6U·1t ~II~

~D ~I ~2

,~ ~

United States Department of the InteriorBUREAU OF LAND MANAGEMENT

Green River DistrictVernal Field Office170 South 500 EastVernal, UT 84078

http://www.blm.gov/ut/st/en/fo/vernal.html

MAR25 2016IN REPLY REFER TO: RECENED3160 (UTGO11)

Kaylene GardnerEOG Resources Inc.600 17thStreet, Suite 1000 N

DIV.0FOIL,GAS&MININ

Denver, CO 80202

Dear Kaylene:

The referenced Applications for Permit to Drill (APD) have expired. According to our records, noknown activityhas transpired at the approved location. In view of the foregoing, this office is notifyingyou that the approval of the referenced applications has expired. If you intend to drill at theselocations in the future, a new Application for Permit to Drillmust be submitted.

Lease Well Aliquot Sec., T., R. Approved Expiration Extension Exp.UTU-0285A 1530-25D NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 §i (UTU-0285A 1531-25D NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016UTU-0285A 1532-25D NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 $}UTU-0285A 1533-25D NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 •J')UTU-0285A 1534-25D NWNE Sec. 25-T9S-R22E 2/17/2012 2/17/2014 2/17/2016 g)UTU-0285A 1535-25D NWNW Sec. 25-T9S-R22E 3/9/2012 3/9/2014 3/9/2016 gj gUTU-0285A 1536-25D NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 691UTU-0285A 1537-25D NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 yUTU-0285A 1538-25D NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016UTU-0285A 1539-25D NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 6) jgUTU-0285A ¡ 1540-25D NWNW Sec. 25-T9S-R22E 3/8/2012 3/8/2014 3/8/2016 6¡ ¡

This office requires a letter confirming that no surface disturbance has been made for these drill sites.Any surface disturbance associated with the approved location of these wells is to be rehabilitated. Aschedule for this rehabilitation must be submitted to this office.

Your cooperation in this matter is appreciated. Ifyou have any questions regarding this matter, pleasecontact Jeanne E. Newman at (435) 781-4488.

Sincerely,

KenczkaAssistant Field ManagerLands & Mineral