  • POWER GENERATIONSOLUTIONS

    Progetto1:Layout 1 30/05/11 12:12 Pagina 3

  • ANSALDO ENERGIA Power Generation SolutionsAnsaldo Energia is a global supplier of turn-key powerplants and offers the full set of the most reliable andbest performing solutions available today.Ansaldo Energia is one of the few companies in theworld able to offer a broad range of products as manu-facturer of all the main power plant components, sup-plying whole plants as well as power blocks in bothopen and combined cycles. Ansaldo Energia is fully acknowledged today as an EPCfor turnkey projects, and therefore as a global plantengineering contractor. Ansaldo Energia, whose customers include public bod-ies, independent power producers and industrial com-panies, is an independent operator with fully proven,proprietary technologies. Ansaldo Energia has references on all five continentsand enjoys an outstanding reliability record.

    Thanks to full-cycle experience and a flexible approachto power projects, the companys role can range fromOriginal Equipment Manufacturer to parts & servicesupplier, and from general contractor to co-developer.All the main new plants are also covered by importantcontracts for service and long term maintenanceassistance.This scenario has translated into more than 33,000MW installed in the first decade of the new century.

    Ansaldo Energia and equipmentAnsaldo Energia state-of-the-art power generation tech-nology stems from about a century of experience in thevarious engineering fields.Ansaldo Energia invests constantly and increasingly toprovide significant resources for development pro-grammes, particularly in relation to combustion, thermo-fluid dynamics, automation and special materials.One example of this is growing market demand for highefficiency and low emissions, which has led to thedevelopment of the cutting-edge VeLoNOx burnersand to a series of new patents for use in all upgradedgas turbines models.

    Power Plant Flexibility and OptimizationToday power plant operational flexibility is a key successfactor to ensure economic return in a liberalized market fornew and existing fossil power plants. Ansaldo Energia pro-vides and develops tailor-made solutions to enhance powerplant operational flexibility by leveraging the full breadth ofexperience accumulated from previous projects.All products and plants are designed to offer:high flexibilitymaximum safetystate-of-the art control systemshighly environmental-friendly features such as zero liquid discharge

    remote diagnostics and assistanceThis is obtained through the accurate and effective simu-lation of both processes and plant components during thedesign and test phases, and thanks to the quality of theautomation systems and I&C, supplied both for turnkeyplants and components. Taking care of the customersneeds during the entire lifetime of the supply is the start-ing point for Ansaldo Energia in every project and in eachrelationship.

    Progetto1:Layout 1 30/05/11 12:12 Pagina 5

  • The complete range of activities covers gas turbines,steam turbines, generators and complete open/com-bined cycle plants, with services which are tailored tothe individual requirements of the customer:Long Term Service Agreements (LTSA)Field Service (Planned Maintenance, Emergency Interventions)

    Solutions/UpgradesSpare partsRepair ActivitiesRemote Monitoring and DiagnosticsSecond hand Power Plants/Equipment relocationsThe companys experience of long term collaborationswith its customers is demonstrated by current activeengagements: more than 40 gas turbine LTSAs on 68units, 26 LTSA Customers in 12 countries, totallingmore than 22 GW.

    Service Offering

    The Ansaldo Energia service offering leveragesadvanced technologies, field expertise and flexibility inrelationships in order to enable utilities and plant man-agers to optimize plant efficiency and reliability, thusreducing operating and life cycle costs.In addition, Ansaldo Energia can offer service activitiesfor third party equipment thanks to its OSP businessline, which combines the expertise of the OEM with theflexibility of the ISP.Ansaldo Energia has chosen to focus on customer serv-ices in order to combine the proven design expertise,manufacturing capabilities and commissioning skills ofits New Units business line with excellence in the after-sale phase, thanks in particular to rapidity of responseand intervention, technical capabilities and expertise, ahigh quality supply chain, and well known flexibility inmatching customer needs.

    Gas TurbinesThe gas turbine offering is entirely based on fully proven,proprietary technology. Ansaldo Energia gas turbines arefully competitive in terms of all market drivers in theheavy duty segment: efficiency, power output, reliability,operational flexibility and emission levels. Gas turbines ranging from 70 MW to more than 290 MWare continuously improved by a dedicated R&D team.Ansaldo Energia has received orders for more than 150gas turbines and 27 GW worldwide, with an installedfleet exceeding 6 Million Operating Hours.

    Steam TurbinesAnsaldo Energia offers a comprehensive portfolio ofhighly reliable, efficient and operationally flexible steamturbines for all fossil-fired power plant applications (com-bined cycles, steam power plants and geothermal, co-

    generation and industrial applications), with output up to800 MW. Ansaldo Energia has extensive design, manu-facturing and installation experience, with more than1,200 units in service or on order totalling 89 GW. Of these more than 300 units are rated above 100MW.

    Turbo GeneratorsAnsaldo Energia experience in the design and construc-tion of turbogenerators up to 1220 MVA dates back to1920: it covers mainly gas, steam, and gas & steam forsingle shaft configurations and geothermal applications,and offers a wide range of air-cooled, hydrogen-cooledand hydrogen/water-cooled turbogenerators, creating acomprehensive portfolio of highly reliable, efficient andoperationally flexible machines. Since 1950, more than 700 units (over 300 in the lastten years) have been manufactured, for a total installedgenerating capacity of over 100 GVA.

    Progetto1:Layout 1 30/05/11 12:12 Pagina 6

  • Ansaldo Energia Contracts for large Power Plants(Combined Cycle/Open Cycle) in the period 2001-2011

    Contract Site Configuration Type of supply Commercial contract operation

    Servola Brownfield 200 MW (1+1) Multishaft syngas CC EPC Contract 2001

    Ballylumford Brownfield 500 MW (2+1) Multishaft CC EPC Contract 2003+ 100 MW (1+1) Single shaft CC

    Ferrera Erb. Brownfield 800 MW 2x(1+1) Multishaft CC Supply and installation of power block 2003+2004+ 200 MW (1+1) Multishaft syngas CC

    Ravenna Brownfield 800 MW 2x(1+1) Multishaft CC Supply and installation of power block 2004

    Mantova Brownfield 800 MW 2x(1+1) Multishaft CC Supply and installation of power block 2005

    Voghera Greenfield 400 MW (1+1) Single shaft CC Supply and installation of power block 2005

    Brindisi Brownfield 1200 MW 3x(1+1) Multishaft CC Supply and installation of power block 2005

    Rosignano Brownfield 400 MW (1+1) Single shaft CC EPC Contract 2007

    Sparanise Greenfield 800 MW 2x(1+1) Multishaft CC EPC Contract 2007

    Lein Greenfield 400 MW (1+1) Multishaft CC EPC Contract 2007

    Vado Ligure Repowering 800 MW (2+1) Multishaft CC EPC Contract 2007

    Rizziconi Greenfield 800 MW 2x(1+1) Multishaft CC EPC Contract 2008

    Moncalieri Repowering 400 MW (1+1) Multishaft CC EPC Contract 2008

    Napoli Levante Repowering 400 MW (1+1) Multishaft CC EPC Contract 2008

    Escatron Brownfield 800 MW (2+1) Multishaft CC Supply and installation of power block 2008

    Ferrara Brownfield 800 MW 2x(1+1) Multishaft CC Supply and installation of power block 2008+2009

    Larbaa Greenfield 500 MW (4 TG) Open cycle EPC Contract 2009

    Batna Greenfield 250 MW (2 TG) Open cycle EPC Contract 2009

    M'Sila Brownfield 500 MW (2 TG) Open cycle EPC Contract 2009

    Algeiras Repowering 400 MW (1+1) Multishaft CC Supply and installation of power block 2010800 MW 2x(1+1)

    Marcinelle Greenfield 400 MW (1+1) Single shaft CC Supply and installation of power block 2010

    Thisvi Greenfield 400 MW (1+1) Multishaft CC Supply and installation of power block 2010

    Turano Lodigiano Greenfield 800 MW (2+1) Multishaft CC EPC Contract 2010

    Aprilia Greenfield 800 MW (2+1) Multishaft CC EPC Contract 2011

    San Severo Greenfield Single shaft CC EPC Contract (1+1) 400 MW 2011

    Bayet Greenfield Single shaft CC EPC Contract (1+1) 400 MW 2011

    Dunamenti Greenfield 400 MW (1+1) Multishaft CC Supply and installation of power block 2011

    Torino Nord Greenfield 400 MW (1+1) Multishaft CC Supply and installation of power block 2011

    Progetto1:Layout 1 30/05/11 12:12 Pagina 4

  • Progetto1:Layout 1 30/05/11 12:12 Pagina 1

  • San Severo 1 x 400 MWCombined Cycle

    Power Plant

    Scheda SanSevero_LO:San Severo 11/02/11 14:47 Pagina 1

  • Contract: San Severo

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: En Plus S.p.A. (Atel)Type of supply contract: EPC ContractCountry: ItalySite Type: GreenfieldService Agreement: LTSACommercial operation: 2011

    Main characteristicsPlant main featuresSan Severo is composed of a 1+1 combined cycle unit insingle shaft configuration with air condenser for electricalenergy production. The expected plant efficiency is over57%. This power plant is equipped with the new flexibilitypackage to fulfil the new energy market requirement. The minimum technical load of the gas turbine, thanksto the new VeLoNOxTM burners, will be lower than the 45%. In this plant the new proprietary ZLD system has beenimplemented to reduce the fresh water consumption andto comply with the local regulation that prohibits any liq-uid effluents emission from the industrial sites. This sys-tem allows an industrial water recover of about the 98%.

    Gas TurbineAE94.3A x 280 MW - 50 HzMain fuel: natural gas

    Steam TurbineMT15 x 135 MW - 50 Hz118/30.3/4.63 bar - 546/536/265C

    Generator50THR - L63 - 470 MVA - 20 kV - 50 Hz - H2 cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation,drum type with integrated deareator.

    Cooling SystemAir Condenser, single row, 24 modules, double speed type.

    Configuration: 400 MW (1+1) Single shaft CC

    HRSG Cond.

    GEN STGT

    Scheda SanSevero_LO:San Severo 11/02/11 14:47 Pagina 2

  • Bayet 1 x 400 MWCombined Cycle

    Power Plant

    Scheda Bayet_LO:Bayet 11/02/11 14:46 Pagina 1

  • Contract: Bayet

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: 3CB SAS (Atel)Type of supply contract: EPC contractCountry: FranceSite Type: GreenfieldService Agreement: LTSACommercial operation: 2011

    Main characteristicsPlant main featuresBayet is a 1+1 combined cycle unit in single shaft configu-ration with air condenser for electrical energy production.The expected plant efficiency is over 57%.This power plant is equipped with the new flexibility pack-age to fulfil the energy market requirement. The minimum technical load of the gas turbine, thanksto the new VeLoNOxTM burners, will be lower than the 45%.Moreover this plant is designed to hold also wide rangeof ambient temperatures. It is also to highlight themethod of participation to the primary and secondaryfrequency regulation that involves also the steam turbine.

    Gas TurbineAE94.3A x 280 MW - 50 HzMain fuel: natural gas

    Steam TurbineMT15 x 135 MW - 50 Hz118/30.3/4.63 bar - 546/536/265C

    Generator50THR - L63 - 470 MVA - 20 kV - 50 Hz - H2 cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation,drum type with integrated deareator.

    Cooling SystemAir Condenser, single row, 24 modules, double speed type.

    Configuration: 400 MW (1+1) Single shaft CC

    HRSG Cond.

    GEN STGT

    Scheda Bayet_LO:Bayet 11/02/11 14:46 Pagina 2

  • Turano Lodigiano 1 x 800 MWCombined Cycle

    Power Plant

    Scheda Turano Lodigiano_AW:lodi 10/05/11 11:47 Pagina 1

  • The Turano Lodigiano/Bertonico power plant, situatednear Lodi in northern Italy, is owned by Sorgenia S.p.A.,an important private operator on the Italian market forelectric power and natural gas, with a strong focus onrespect for the environment and clean energy.The plant is located in a recently reclaimed industrialarea that was previously occupied by a refinery demoli-shed in the early 1980s, and there are plans to re-qualifythe surrounding area by developing industrial and arti-san sites nearby. In April 2008 Ansaldo Energia was awarded the EPC con-tract to build the power plant on a turnkey basis and aLong Term Service Agreement (LTSA) to maintain the 2gas turbines and relative generators. In 2009 the custo-mer, based in part on positive experience gained at Tu-rano, awarded Ansaldo Energia a similar contract for thesister plant in Aprilia (Province of Latina). The power plant comprises a combined cycle with twogas turbines and one steam turbine (2+1 configuration),delivering a nominal output of 800 MW.The work assigned to Ansaldo Energia as EPC Contrac-tor included the design, supply, on-site installation, start-up and testing of the entire power plant, comprising themain components in the power block.The turnkey supply of which Ansaldo Energia is in chargealso covers the gas station, the thermal cycle, the auxi-liary systems, including one auxiliary boiler and a waterdemineralisation and recover plant (ZLD), the HV, MV

    and LV electrical equipment, including one metal-cladgas insulated switchgear (GIS) for connection to theTerna substation, the plant automation system (DCS)and the design and implementation of civil works for theentire plant. Third parties commissioned directly by thecustomer developed the natural gas feeding system andthe high voltage electric substation.The distinctive features of the project are its focus onenvironmental issues and excellent operating flexibility,which are critical success factors for power producerstoday, who are faced with an ever more competitive mar-ket and a society increasingly aware of environmentalproblems. A combined cycle solution plus Ansaldo Ener-gia technology delivers excellent plant performance withlow atmospheric emission impact. The class 4 AE94.3Agas turbine with VeLoNOx burners has been succes-sfully tested on other power plants and the base load ef-ficiency measured during testing was higher than 57%,with CO and NOx emissions much lower than 30 mg/Nm3.The results of plant efficiency tests at partial load wereequally satisfactory. The management of water resourceswas also a key focus and the plant has a Zero Liquid Di-scharge (ZLD) water treatment system that reduces theinput of process water from wells, as well as a powerfulair condenser used to condense the steam without re-sorting to external water resources for cooling. Although the power plant is situated in an industrial areaaway from population settlements, the design meets

    Turano Lodigiano 1 x 800 MWCombined Cycle Power Plant

    Scheda Turano Lodigiano_AW:lodi 10/05/11 11:47 Pagina 2

  • specific architectural requirements to ensure environ-mental and landscape integration in such a way as toreduce visual and acoustic impact. The buildings areclad in panels that insulate from and absorb sound,which represent one of the main visual features of theplant, along with the big hexagonal concrete stack about100 m high and the brick red colour used for variousplant sections, recalling the natural colours of the areasurrounding the plant. So far as power generation is con-cerned, the plant has been designed to meet the voltageand frequency regulation requirements of the Italiantransmission network as stipulated by Terna (the ItalianNational Grid operator), while on a functional level theplant has been designed to deliver maximum operatingflexibility in accordance with legal atmospheric pollutantemission criteria. The customer can vary load on a dailybasis in peak hours and during the weekend. Rapidplant start up allows the customer to begin generatingpower quickly, as well as to operate with different plantconfigurations and variable loads, providing a rapid andflexible response to network demand.The project was given the Notice to Proceed by the cu-stomer in April 2008 and construction work began in Fe-bruary 2009. A constant focus on the real needs of thecustomer and the climate of proactive collaborationestablished, together with technical expertise and care-ful planning and monitoring of work, have made it pos-sible to achieve the general project objectives and,

    specifically, plant delivery (PAC issued by customer Sor-genia) in just 30 months from the NTP. Site work (civilworks, electromechanical assembly, start-up activitiesand testing) involved up to about 850 people on site inpeak periods and was performed in such a way as to en-sure the health and safety of both its own workers, andthose of associated companies and sub-contractorsworking on site. With the final hand-over of the plant to the customer,planned for November 2010, the Long Term ServiceAgreement covering maintenance will come into effect. Under the terms of this contract Ansaldo Energia is com-mitted for 7+7 years to managing and performing rou-tine maintenance and repair work on the 2 gas turbinesets, undertaking to maintain performance values withminimum deterioration and high turbo generator availa-bility values for the entire duration of the contract. The agreement also entails operating parameter loggingand remote monitoring 24/7 from the diagnostic controlroom at Ansaldo Energias Genoa production facility.

    Scheda Turano Lodigiano_AW:lodi 10/05/11 11:47 Pagina 3

  • Contract: TuranoLodigiano

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: SorgeniaType of supply contract: EPC ContractCountry: ItalySite Type: GreenfieldService Agreement: LTSACommercial operation: 2010

    Main characteristicsPlant main featuresTurano Lodigiano is a 2+1 combined cycle unit with aircondenser for electrical energy production. The expectedplant efficiency is over 57%. The plant minimum technicalload, thanks to the new VeLoNOxTM burners, will be aboutthe 50%. This power plant is characterized by an architec-tonical cover solution for the main components and for theHRSG stack to minimize the environmental impact andpromote the plant acceptance and territorial integration.Moreover, to reduce the environmental impact, the newproprietary ZLD system has been implemented to reducethe fresh water consumption and to comply with the localregulation that prohibits any liquid effluents emission fromthe industrial sites. This system allows an industrial waterrecover of about the 98%.

    Gas TurbineAE94.3A x 277.2 MW - 50 HzMain fuel: natural gas

    Steam TurbineRT30 x 268 MW - 50 Hz123/28.5/4.9 bar - 544/549/231C

    GeneratorGT units: TRY - L56 - 330 MVA - 18 kV - 50 Hz - air cooledST unit: TRX - L56 - 330 MVA - 18 kV - 50 Hz - air cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation,drum type with integrated deareator.

    Cooling SystemAir Condenser, single row, 24 modules, double speed type.

    Configuration: 800 MW (2+1) Multishaft CC

    GEN HRSG

    HRSG

    Cond.GEN

    GT

    GEN GT

    ST

    Scheda Turano Lodigiano_AW:lodi 10/05/11 11:48 Pagina 4

  • M'Sila 500 MWOpen CyclePower Plant

    Scheda MSila_LO:MSila 13/10/10 11:30 Pagina 1

  • Contract: MSila

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209E-mail: [email protected] - [email protected] - www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: SonelgazType of supply contract: EPC ContractCountry: AlgeriaType of site: Brownfield Service Agreement: Spare Parts Commercial operation: 2010

    Configuration:500 MW (2 GTs) OC

    GT GEN

    GT GEN

    Main characteristicsPlant main featuresM'Sila projet is a 2 x 215 MW GT based power plant inopen cycle configuration delivered as turn-key contract. It is provided for mulfifuel service with natural gas asmain fuel and light oil as back-up fuel.The plant is equipped with gas reducing station, firefigthingfacilities, black start diesel, demi production and watertreatment units and auxiliaries buildings for administrationand workshop. Conceived as an extension of the existing plant, thescope of supply includes all facilities for the telesurveil-lance and anti-intrusion systems along the whole fencefor a perimeter longer than 3.5 km.MSila power plant has been designed full in compliancewith Customer requirements to get high availability, per-formance and respect of natural and human environ-ment.

    Gas TurbineAE94.3A x 215 MW - 50 HzMain fuel: natural gas /oil distillate

    GeneratorWY23Z-109LL - 300 MVA - 19 kV - 50 Hz - air cooled

    Scheda MSila_LO:MSila 13/10/10 11:30 Pagina 2

  • Larbaa 500 MWOpen CyclePower Plant

    Scheda Larbaa_LO:Larbaa 13/10/10 11:37 Pagina 1

  • Contract: Larbaa

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209E-mail: [email protected] - [email protected] - www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: SonelgazType of supply contract: EPC ContractCountry: AlgeriaRepowering: Greenfield Service Agreement: Spare PartsCommercial operation: 2010

    Configuration:500 MW (4 GTs) OC

    GT GEN

    GT GEN

    GT GEN

    GT GEN Main characteristicsPlant main featuresLarbaa projet is a 4 x 140 MW GT based power plant inopen cycle configuration delivered as turn-key contract in-cluding extension of the existing 220 kV open air substa-tion equipped with double bus-bar and 4 additional bays.It is provided for mulfifuel service with natural gas asmain fuel and light oil as back-up fuel. The plant is equipped with gas reducing station, fuel storagetanks (4 x 9000 m3 capacity), black start diesel, firefigthingfacilities, demi production and water treatment units andauxiliaries buildings for administration, workshop and storefor spare parts. Conceived as greenfield installation, the scope of supplyincludes all facilities for the telesurveillance and anti-in-trusion systems along the whole fence for a perimeterlonger than 2.0 km. Larbaa power plant has been designed in full compliancewith Customer requirements to get high availability, per-formance and respect of natural and human environment.Performance tests have been succesfully completed withimproved power output (1.2% higher than guaranteedvalue) and reduced fuel consumption (1.4% less thanguaranteed value) with important benefits as it regardsour Customer investment.

    Gas TurbineAE94.2 x 140 MW - 50 HzMain fuel: natural gas /oil distillate + w.inj

    GeneratorWY21Z-092RR - 190 MVA - 15.5 kV - 50 Hz - air cooled

    Scheda Larbaa_LO:Larbaa 13/10/10 11:37 Pagina 2

  • Batna 250 MWOpen CyclePower Plant

    Scheda Batna_LO:Batna 13/10/10 11:41 Pagina 1

  • Contract: Batna

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209E-mail: [email protected] - [email protected] - www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: SonelgazType of supply contract: EPC ContractCountry: AlgeriaRepowering: Greenfield Service Agreement: Spare PartsCommercial operation: 2010

    Main characteristicsPlant main featuresBatna projet is a 2 x 127 MW GT based power plant inopen cycle configuration delivered as turn-key contract in-cluding a 220 kV open air substation with double bus-barsystem and 11 bays. It is provided for mulfifuel servicewith natural gas as main fuel and light oil as back-up fuel.The plant is equipped with gas reducing station, fuel storagetanks (2 x 9000 m3 capacity), black start diesel, firefigthingfacilities, demi production and water treatment units andauxiliaries buildings for administration, workshop and storefor spare parts.Conceived as greenfield installation, the scope of supplyincludes all facilities for the telesurveillance and anti-in-trusion systems along the whole fence for a perimeterlonger than 3.0 km. Batna power plant has been designed full in compliancewith Customer requirements to get high availability, per-formance and respect of natural and human environment.Performance tests have been succesfully completed withimproved power output (2.8% higher than guaranteedvalue) and reduced fuel Consumption (1.5% less thanguaranteed value) with important benefits as it regardsour Customer investment.

    Gas TurbineAE94.2 x 127 MW - 50 HzMain fuel: natural gas /oil distillate + w.inj

    GeneratorWY21Z-092RR - 190 MVA - 15.5 kV - 50 Hz - air cooled

    Configuration:250 MW (2 GTs) OC

    GT GEN

    GT GEN

    Scheda Batna_LO:Batna 13/10/10 11:41 Pagina 2

  • Napoli Levante 1 x 387 MWCombined Cycle

    Power Plant

    Scheda Napoli_LO:Napoli 08/09/10 18:31 Pagina 1

  • Configuration: 400 MW (1+1) Multishaft CC

    Contract: Napoli Levante

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: Tirreno PowerType of supply contract: EPC ContractCountry: ItalySite Type: RepoweringService Agreement: LTSACommercial operation: 2009

    Main characteristicsPlant main featuresNapoli Levante is the repowering as 1+1 400 MW com-bined cycle unit of the existing 150 MW unit 3 ofNaples' power plant. The existing steam turbine and itsauxiliaries, the steam turbine pedestal, the steam tur-bine generator and the surface condenser were over-hauled and refurbished to be reused in the new unit.Coming the natural gas from SNAM town pipeline a com-pressor station was necessary. The automation systemis based upon field bus technology.

    Gas TurbineAE94.3A x 264 MW - 50 HzMain fuel: natural gas

    Steam TurbineRT x 134 MW - 50 Hz116/34/6.4 bar - 545/550/244C

    GeneratorGT unit: WY23Z-109LL - 300 MVA - 20 kV - 50 Hz - aircooledST unit: ATH 170000/2 - 170 MVA - 15 kV - 50 Hz - H2cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator

    Cooling SystemSea water surface condenser.

    GENHRSG

    Cond.GEN

    GT

    ST

    Scheda Napoli_LO:Napoli 08/09/10 18:31 Pagina 2

  • Moncalieri 1 x 389 MWCombined Cycle

    Power Plant

    Scheda Moncalieri_LO:Moncalieri 08/09/10 18:29 Pagina 1

  • Configuration: 400 MW (1+1) Multishaft CC

    Contract: Moncalieri

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: IrenType of supply contract: EPC ContractCountry: ItalySite type: RepoweringService Agreement: LTSACommercial operation: 2008

    Main characteristicsPlant main featuresMoncalieri is a 1+1 combined cycle unit for electrical andthermal energy production. It is connected to Torino districtheating grid and can produce a thermal power of over 260MWt. Moncalieri is the repowering of an existing 141 MWconventional unit and it is able to work not only in com-bined cycle configuration but also as a conventional cyclethanks to the piping connections to the existing firedsteam generator. During the commissioning phase thenew authomatic start-up sequence was successfullytested and applied to this plant. Due to transportationconstraints, the gas rurbine was assembled at site.

    Gas TurbineAE94.3A x 265 MW - 50 HzMain fuel: natural gas

    Steam TurbineExisting ST x 130 MW - 50 Hz85/24.5/3.68 bar - 536/536/221C

    GeneratorGT unit: WY23Z-109LL - 300 MVA - 19 kV - 50 Hz - aircooledST unit: WX21Z-092RR - 170 MVA - 15.75 kV - 50 Hz - aircooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemSurface condenser.

    GENHRSG

    Cond.GEN

    GT

    ST

    Scheda Moncalieri_LO:Moncalieri 08/09/10 18:29 Pagina 2

  • Rizziconi 2 x 385 MWCombined Cycle

    Power Plant

    Scheda Rizziconi_LO:Rizziconi 08/09/10 18:30 Pagina 1

  • Contract: Rizziconi

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: Rizziconi Energia (EGL)Type of supply contract: EPC ContractCountry: ItalySite type: GreenfieldService Agreement: LTSA (GTF)Commercial operation: 2008

    Main characteristicsPlant main featuresRizziconi is composed of 2 x (1+1) combined cycle unitsin multi shaft configuration with air condenser for elec-trical energy production. The plant efficiency is over56%. These two units were designed to be as much aspossible similar to Sparanise combined cycle units formaintenance and operating reasons.

    Gas TurbineAE94.3A x 263 MW - 50 HzMain fuel: natural gas

    Steam TurbineMT15 x 132 MW - 50 Hz118/31/4.6 bar - 549/558/236C

    GeneratorGT units: WY23Z-109LL - 300 MVA - 19 kV - 50 Hz - aircooledST units: WY21Z-092LLT - 170 MVA - 15.75 kV - 50 Hz -air cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemAir Condenser, multi row, 21 modules, double speed type.

    GENHRSG

    Cond.

    Cond.

    HRSG

    GEN

    GEN

    GEN

    GT

    ST

    GT

    ST

    Configuration: 800 MW 2x(1+1) Multishaft CC

    Scheda Rizziconi_LO:Rizziconi 08/09/10 18:30 Pagina 2

  • Escatron 1 x 800 MWCombined Cycle

    Power Plant

    Scheda Escatron_LO:Escatron 08/09/10 18:27 Pagina 1

  • Contract: Escatron

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: EnelType of supply contract: Supply & install. of power blockCountry: SpainSite type: BrownfieldService Agreement: FA (Field Activity)Commercial operation: 2008

    Main characteristicsPlant main featuresEscatron is a 2+1 combined cycle unit. Ansaldo Energiasupplied the entire power block composed of the two gasturbines with their generators, the two HRSGs and thesteam turbine with its generator. Escatron was the firstsuccessful application of the new AE94.3A upgradedmodel. Due to trasportation constraints, the gas turbinewas assembled at site.

    Gas TurbineAE94.3A x 267 MW - 50 HzMain fuel: natural gas/oil distillate as back up fuel

    Steam TurbineRT30 x 273 MW - 50 Hz124/27.8/4.86 bar - 548/553/229C

    GeneratorGT units: WY23Z-109LL - 300 MVA - 19 kV - 50 Hz - aircooledST unit: WX23Z-109LL - 300 MVA - 19 kV - 50 Hz - aircooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemSurface condenser with closed cooling tower, suppliedby Enel.

    GEN HRSG

    HRSG

    Cond.GEN

    GT

    GEN GT

    ST

    Configuration: Multishaft CC (2+1) 800 MW

    Scheda Escatron_LO:Escatron 08/09/10 18:28 Pagina 2

  • Sparanise 2 x 385 MW Combined Cycle

    Power Plant

    Scheda Sparanise_LO:G_624/08_Ansaldo Scheda Sparanise 08/09/10 18:32 Pagina 1

  • Configuration: 800 MW 2x(1+1) Multishaft CC

    Client: Calenia Energia (EGL)Type of supply contract: EPC Contract Country: ItalySite type: GreenfieldService Agreement: LTSA (GTF)Commercial operation: 2007

    Contract: Sparanise

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    GENHRSG

    Cond.

    Cond.

    HRSG

    GEN

    GEN

    GEN

    GT

    ST

    GT

    ST

    Main characteristicsPlant main featuresSparanise is composed of 2x(1+1) combined cycle unitsin multi shaft configuration with air condenser for electri-cal energy production. The plant efficiency is over 56%. The measured plantavailability during the first period of operation is well overguaranteed figure. The plant often works delivering a20% band as secondary frequency regulation.Sparanise is the first Italian power station realised forEGL: it has been designed to get the maximum respectfor the natural and human environment; so advancedtechnology guaranteed high efficiency and emissionsbelow European regulation limits, while innovative ar-chitectural solutions met client's request to reduce sightimpact. Both the high efficiency and the high availabilityhelp the customer to get as much as possible returnfrom his investment.

    Gas TurbineAE94.3A x 263 MW - 50 HzMain fuel: natural gas.

    Steam TurbineMT15 x 132 MW - 50 Hz117/31.1/4.6 bar - 549/558/236C

    GeneratorGT unit: WY23Z-199LL - 300 MVA - 19 kV - 50 Hz - aircooled ST unit: WY21Z-092LLT - 170 MVA - 15.75 kV - 50 Hz -air cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemAir Condenser, multi row, 21 modules, double speed type.

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Scheda Sparanise_LO:G_624/08_Ansaldo Scheda Sparanise 08/09/10 18:32 Pagina 2

  • Lein 1 x 385 MWCombined Cycle

    Power Plant

    Scheda Leini_LO:Leini 08/09/10 18:28 Pagina 1

  • Configuration: 400 MW (1+1) Multishaft CC

    Contract: Lein

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: AceaElectrabelType of supply contract: EPC ContractCountry: ItalySite type: GreenfieldService Agreement: LTSACommercial operation: 2007

    Main characteristicsPlant main featuresLein is a 1+1 combined cycle unit in multi shaft arrange-ment with air condenser for electrical and thermal energyproduction. The plant efficiency is over 56%. The plant isable to discharge a total thermal energy for district heatingand cogeneration for industrial application of 200 MWt.

    Gas TurbineAE94.3A x 265 MW - 50 HzMain fuel: natural gas

    Steam TurbineRT20 x 128.5 MW - 50 Hz115/31/4.6 bar - 545/553/236C

    GeneratorGT unit: WY23Z-109LL - 300 MVA - 19 kV - 50 Hz - aircooledST unit: WX21Z-092LLT - 160 MVA - 15.75 kV - 50 Hz -air cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemAir Condenser, single row, 18 modules, double speed type.

    GENHRSG

    Cond.GEN

    GT

    ST

    Scheda Leini_LO:Leini 08/09/10 18:28 Pagina 2

  • Vado Ligure 1 x 781 MWCombined Cycle

    Power Plant

    Scheda Vado_LO:Vado 08/09/10 18:33 Pagina 1

  • Configuration: 800 MW (2+1) Multishaft CC

    Contract: Vado Ligure

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: Tirreno Power (Suez/Sorgenia)Type of supply contract: EPC ContractCountry: ItalySite type: Brownfield/RepoweringService Agreement: LTSACommercial operation: 2007

    Main characteristicsPlant main featuresVado Ligure is a 2+1 combined cycle unit obtained re-powering the existing heavy oil fired block of Vado Ligurepower plant. This choice allowed for the client a greatsaving in terms of efficiency, spaces and emissions with-out considering that the steam turbine and its auxiliaries,the existing pedestal, the sea water condenser and thesteam turbine generator were overhauled and refur-bished to be reused in the new unit. Moreover the new automation system based upon fieldbus technology was successfully tested.

    Gas TurbineAE94.3A x 264 MW - 50 HzMain fuel: natural gas

    Steam TurbineRT x 267 MW - 50 Hz126/31/4.2 bar - 551/556/244C

    GeneratorGT units: WY23Z-109LL - 300 MVA - 20 kV - 50 Hz - aircooledST unit: ATH 370000/2 - 370 MVA - 20 kV - 50 Hz -H2/H2O cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemSea water surface condenser. The circulating water systemuses the existing sea water intake and sea water dischargechannel with new circulating water pumps.

    GEN HRSG

    HRSG

    Cond.GEN

    GT

    GEN GT

    ST

    Scheda Vado_LO:Vado 08/09/10 18:33 Pagina 2

  • Rosignano 1 x 388 MWCombined Cycle

    Power Plant

    Scheda Rosignano_LO:Rosignano 08/09/10 18:29 Pagina 1

  • Contract: Rosignano

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Main characteristicsPlant main featuresRosignano is a 1+1 combined cycle unit in single shaftarrangement. This brownfield power plant shares someauxiliary facilities with the existing CCU supplied byAnsaldo Energia in 1996. It is the first 400 MW EPC insingle shaft configuration supplied by Ansaldo Energia.Its efficiency is over 56%.

    Gas TurbineAE94.3A x 263 MW - 50 HzMain fuel: natural gas

    Steam TurbineMT15 x 133.5 MW - 50 Hz117/31 4.6 bar - 558/558/234C

    Generator50THR - L63 - 480 MVA - 20 kV - 50 Hz - H2 cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator.

    Cooling SystemSurface condenser with closed cooling tower.

    Configuration: 400 MW (1+1) Single shaft CC

    Client: AceaTractebelType of supply contract: EPC ContractCountry: ItalySite type: BrownfieldService Agreement: LTSACommercial operation: 2007

    HRSG Cond.

    GEN STGT

    Scheda Rosignano_LO:Rosignano 08/09/10 18:30 Pagina 2

  • Voghera 1 x 400 MWCombined Cycle

    Power Plant

    Scheda Voghera_LO:Voghera 08/09/10 18:33 Pagina 1

  • Configuration: 400 MW (1+1) Single shaft CC

    Contract: Voghera

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    HRSG Cond.

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: AceaElectrabelType of supply contract: Supply & install. of power blockCountry: ItalySite type: GreenfieldService Agreement: LTSACommercial operation: 2005

    Main characteristicsPlant main featuresVoghera is a 1+1 combined cycle unit in single shaftconfiguration. This greenfield plant with air condensingsystem, is equipped with the first 400 MW power blockin single shaft configuration supplied by Ansaldo Ener-gia. Power output higher then guaranteed (plus ~8.6 MW).Fuel consumption lower then guaranteed (minus 1.72%).Ambient emissions lower that guaranteed (NOx: 20 ppmversus 25 guaranteed; CO: 0.98 ppm versus 10 guaran-teed).

    Gas TurbineAE94.3A x 259 MW - 50 HzMain fuel: natural gas

    Steam TurbineMT15 x 131.5 MW - 50 Hz117/30.8/4.8 bar - 559/559/234C

    Generator50THR - L63 - 470 MVA - 20 kV - 50 Hz - H2 cooled

    Heat Recovery Steam GeneratorThree pressure levels with RH, natural circulation, drumtype with integrated deareator. Out of Ansaldo EnergiaScope of supply.

    Cooling SystemAir Condenser, single row. Out of Ansaldo Energia Scopeof supply.

    GEN STGT

    Scheda Voghera_LO:Voghera 08/09/10 18:34 Pagina 2

  • Ferrera Erbognone 2 x 400 MW + 1 x 250 MW

    Combined CyclePower Palnt

    Scheda Ferrera_AW:G_624/08_Ansaldo Scheda Ferrera 10/05/11 11:49 Pagina 1

  • In 2001 Ansaldo Energia was awarded the Long ThermService Agreement ( LTSA ) to perform services on thegas turbine, steam turbines and relevant generatorsof the entire Enipower combined cycle fleet.The time frame validity of the above mentioned Con-tract is from the PAC of each power plant up to theachievement of 50 KEOH of each Gas Turbine.The main deliveries of the LTSA are the following:

    Planned maintenance activities on GT, ST, Generator, bypass valves, HVAC

    Unplanned maintenance activities

    Spare parts initial stock and stock replenishment

    Strategic spare parts (spare rotor, Hub, turbine blade carrier, rotor cover)

    Gas turbine blades and vanes refurbishment

    Remote monitoring and diagnostic Warranties: Availability, Power & Efficiency, Emissions

    All the power plant units are continuously monitoredby Ansaldo Energia with the purpose to supply an ef-fective remote diagnostic assistance in the areas ofthermodynamic (Power Output, Efficiency, Turbine InletTemperature, etc.), vibrations, emissions, combustionanalysis.

    The remote monitoring system is also the main toolto support the predictive maintenance.Among the Enipower fleet, Ferrera Erbognone repre-sent a bright example of the first power plant installedand then in operation, and having the AE94.3A gasfired turbine as well as the AE94.2K gas turbine fedwith syngas.

    Ferrera Erbognone Power PlantService activities performed by Ansaldo Energia within the Long Term Service Agreement

    Scheda Ferrera_AW:G_624/08_Ansaldo Scheda Ferrera 10/05/11 11:49 Pagina 2

  • Up to now, in the frame of the LTSA, Ansaldo Energiaalready performed in Ferrera Erbognone the followingactivities of planned maintenance:

    N. 5 Gas Turbine Major Overall

    N. 1 Gas Turbine Hot Gas Path Inspection

    N. 4 Generator Major Overall

    N. 5 Steam Turbine minor inspection (valve inspection)

    N. 24 minor inspection of gas turbine and generator

    Obtaining excellent performance both in term of ou-tage period and machine setting, gaining the Clientsappreciation, having often exceeded the availability tar-get guaranteed in the Contract. During the LTSA period Ansaldo Energia proposed toEnipower several upgrading and TILs with the aim toimprove power output, flexibility, reliability and to re-duce emissions.The main improvements ordered by Enipower and im-plemented by Ansaldo Energia in Ferrera Erbognonepower plant were:

    CMF+: Compressor mass flow increase for power increase

    Fogging system for power increase

    VeLowNox for emission reduction

    Inlet Guide Vanes with Hydraulic actuator for improve reliability and flexibility

    Third accelerometer for vibration monitoring in order to improve the reliability

    Several software and hardware implementation in order to improve load ramps, primary and secondary frequency support, turn down.

    Scheda Ferrera_AW:G_624/08_Ansaldo Scheda Ferrera 10/05/11 11:49 Pagina 3

  • Configuration: 800 MW 2x(1+1) Multishaft CC +250 MW (1+1) Multishaft syngas CC

    Client: EnipowerType of supply contract: Supply & install.of power block Country: ItalySite type: GreenfieldService Agreement: LTSA (GTF)Commercial operation: 2003, 2004

    Contract: Ferrera Erbognone

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

    GENHRSG

    Cond.

    Cond.

    HRSG

    GEN

    GEN

    GEN

    GT

    ST

    GT

    ST

    Main characteristicsPlant main featuresThe contract of Ansaldo Energia with Enipower signed a mile-stone in terms of size, contents, services and Customer. Enipoweris the electric power operator with an important network of petro-chemicals plants spread across Italy providing, ideal locations fornew capacityand with this contract planning 8 combined cy-cles for installation in four industrial areas owned by the group,will deliver a total of about 3,850 MW. The plant, the first of four,rated 1,050 MW featuring two natural gas unit rated about 800MW and a 250 MW syngas unit. One of the key factor of AnsaldoEnergia success was the maintenance and assistance proposalformulated using innovative criteria. Maintenance and assistancealone are worth roughly a quarter of the entire contract amount.The plant also highlights the growing trend in power generationmachinery demand for high base load plant.

    Gas Turbine1 x AE94.2K x 167 MW, 2 x AE94.3A x 258 MW - 50 HzMain fuel: syngas (AE94.2K), natural gas (AE94.3A).

    Steam TurbineST for 2x(1+1) CC: MT15 x 131.5 MW - 50 Hz117/30.8/4.8 bar - 559/559/234C;ST for (1+1) CC: 1 x 88 MW - 50 Hz95/29/6.5 bar - 510/510/260 C

    GeneratorGT units: WY23Z-109LL - 300 MVA - 19 kV - 50 Hz - air cooledST units: WX21Z-092LLT - 170 MVA - 15.75 kV - 50 Hz- air cooledGT Syngas unit: WY21Z-092LLT - 200 MVA - 15.75 kV- 50 Hz - air cooled

    Heat Recovery Steam GeneratorOut of Ansaldo Energia Scope of supply.

    Cooling SystemOut of Ansaldo Energia Scope of supply.

    The

    info

    rmat

    ion

    cont

    aine

    d in

    this

    pub

    licat

    ion

    is p

    rovi

    ded

    for

    illus

    trat

    ive

    purp

    oses

    onl

    y. Pr

    oduc

    t des

    crip

    tions

    and

    con

    tent

    may

    cha

    nge

    in c

    onsi

    dera

    tion

    of s

    peci

    fic m

    arke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    tim

    e fo

    r tec

    hnic

    alor

    com

    mer

    cial

    reas

    ons.

    Cond.

    HRSGGEN

    GEN

    GT

    ST

    Scheda Ferrera_AW:G_624/08_Ansaldo Scheda Ferrera 10/05/11 11:50 Pagina 4

  • Ballylumford 1 x 100 MW + 1 x 500 MW

    Combined CyclePower Plant

    Scheda Ballylumford_LO:Ballylumford 13/10/10 11:34 Pagina 1

  • Contract: Ballylumford

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209E-mail: [email protected] - [email protected] - www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: Premier Power LimitedType of supply contract: EPC ContractCountry: United KingdomRepowering: Brownfield Service Agreement: LTSA Commercial operation: 2003

    Main characteristicsPlant main featuresBallylumford is a 600 MW power plant divided in twounits: block 1 which is a 1+1 single shaft configurationwith the AE64.3A gas turbine, this block discharges over100 MW of electrical power; block 2 which is a 2+1 con-figuration with two AE94.2 gas turbines to discharge over500 MW of electrical power. Both the units are able tofire not only natural gas, but also fuel oil as back up fuel.

    Gas Turbine2 x AE94.2 x 170 MW + 1 x AE64.3A x 67 MW - 50 HzMain fuel: natural gas /oil distillate

    Steam TurbineBlock 1: 1 x 39 MW - 50 Hz HP: 85 bar - 538 C Block 2: 1 x 189 MW - 50 Hz HP: 105/23/3.8 bar - 527/304/224 C

    GeneratorBlock 1: WY21Z-073LLT - 135 MVA - 15 kV - 50 Hz - air cooledBlock 2 GT units: WY21Z-097LLT - 217 MVA - 15 kV - 50 Hz -air cooledBlock 2 ST unit: WX23Z-109LL - 250 MVA - 18 kV - 50 Hz -air cooled

    Heat Recovery Steam GeneratorBlock 1: three pressure levels with RH and integrateddeareator. Block 2: three pressure levels with a common externaldeareator

    Cooling SystemSea water surface condenser

    Configuration:500 MW (2+1) Multishaft CC +100 MW (1+1) Single shaft CC

    GEN HRSG

    HRSG

    Cond.GEN

    GT

    GEN GT

    ST

    GENHRSG

    Cond.GEN

    GT

    ST

    Scheda Ballylumford_LO:Ballylumford 13/10/10 11:34 Pagina 2

  • Servola 1 x 172 MWCombined Cycle

    Power Plant

    Scheda Servola_LO:Servola 13/10/10 11:29 Pagina 1

  • Configuration: 200 MW (1+1) Multishaft syngas CC

    Contract: Servola

    16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209E-mail: [email protected] - [email protected] - www.ansaldoenergia.it

    The

    info

    rmat

    ion

    cont

    aine

    d in

    thi

    s pu

    blic

    atio

    n is

    pro

    vide

    d fo

    r ill

    ustr

    ativ

    e pu

    rpos

    eson

    ly. P

    rodu

    ct d

    escr

    iptio

    ns a

    nd c

    onte

    nt m

    ay c

    hang

    e in

    con

    side

    ratio

    n of

    spe

    cific

    mar

    -ke

    t situ

    atio

    ns. A

    nsal

    do E

    nerg

    ia m

    ay m

    ake

    chan

    ges

    to th

    e de

    scrip

    tions

    pro

    vide

    d at

    any

    time

    for t

    echn

    ical

    or c

    omm

    erci

    al re

    ason

    s.

    Client: Elettra GLTType of supply contract: EPC ContractCountry: ItalyRepowering: BrownfieldService Agreement: LTSACommercial operation: 2001

    Main characteristicsPlant main featuresServola combined cycle power plant is a 1+1 configurationwith sea water surface condenser for electrical and thermalenergy production. The main feature to highlight of thisplant is that it is designed to fire waste gas from steel in-dustry such as BFG (blast-furnace gas) and COG (coke-ovengas). These two fuels are burnt into the combustion cham-ber of the gas turbine together with natural gas. The BFG flow is of about 112000 Nm3/h and the COG flowis of about 19000 Nm3/h. The system is equipped with agas turbine model dedicated to this application with twocompressors on its axial line.Thanks to the solution adoptedthis plant has a CIP6 certification. Finally the plant candischarge industrial steam for cogeneration use. The most important benefit is the use, as fuel, of wastegas from steel industry, mixed with natural gas.

    Gas TurbineAE94.2K x 109 MW - 50 Hz including two stages: LP axialand HP centrifugal waste compressors (22 MW)Fuel: waste gas from steel industry (BFG and COG) mixedwith natural gas

    Steam Turbine1 x 70 MW - 50 HzHP: 76/9.2 bar - 517/285 C

    GeneratorGT & compr.: WY21Z-073LLT - 141 MVA - 15 kV - 50 Hz -air cooledST unit: WY18Z-066LLT - 94 MVA - 11.5 kV - 50 Hz -air cooled

    Heat Recovery Steam GeneratorThree pressure levels: HP level to feed the steam tur-bine; IP level to feed the steam turbine and/or for thecogeneration industrial; the third LP level is to dearatethe condensate flow.

    Cooling SystemSea water surface condenser

    GENHRSG

    Cond.GEN

    GT

    ST

    Scheda Servola_LO:Servola 13/10/10 11:29 Pagina 2

  • Sta

    mpa

    Mic

    roar

    ts S

    pa -

    Rec

    co (

    Ge)

    - 06/2

    007

    Pet

    ergr

    af

    16152 Genova - Italy - Via N. Lorenzi, 8Phone. +39.010.6551 - Fax +39.010.6556209E-mail: [email protected]

    Ansaldo Energia has over 150 years experience inthe electrical and mechanical engineering business. It is a global player in the power generation sectorwith an installed capacity of over 177,000 MW.Ansaldo Energia offers the full range of manufacturing,engineering, contracting and service activities, aswell as a flexible approach to power projects.Steam Fossil fired, Gas Turbine and CombinedCycle, Hydroelectric, Geothermal and Nuclear PowerPlants, supplied turnkey, in separate lots or by com-ponents.The Quality Systems, certified as complying with ISO9001 by a recognised certification society, cover allaspects including, design, planning, manufacture,testing, inspection, installation and servicing.

    Progetto1:Layout 1 30/05/11 12:12 Pagina 2