Description and operating instructions Industrial ETHERNET Rail Switch 2 The Rail Switches – RS2-3TX/2FX EEC – RS2-3TX/2FX-SM EEC – RS2-4TX/1FX EEC – RS2-4TX/1FX-ST EEC – RS2-4TX/1FX-SM EEC – RS2-4TX EEC in short RS2-xTX/xFX EEC, are switches especially designed for use in industrial environments. They support ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The Rail Switch modules support switched ETHERNET networks in accordance with IEEE standard 802.3 using copper and fiber optic technology. The switch modules are plugged onto the standard DIN rail. The RS2-3TX/2FX… modules have three 10/100 MBit/s twisted pair ports (10/100BASE-TX, RJ45 connectors) and two 100 MBit/s fiber optic ports (100BASE-FX, Duplex SC connector). It is possible to connect up to three DTEs or other TP/TX network segments to the TP/TX ports using twisted pair cabling. Two further DTEs or optical network components can be connected to the fiber ports. The RS2-4TX/1FX… modules have four 10/100 MBit/s twisted pair ports (10/100BASE-TX, RJ45 connectors) and one 100 MBit/s fiber optic port (100BASE-FX, Duplex SC connector or ST connector on R2-4TX/1FX-ST EEC). The RS2-4TX EEC module has four 10/100 MBit/s twisted pair ports (10/100BASE-TX, RJ45 connectors). It is possible to connect up to four DTEs or other TP/TX network segments to the TP/TX ports using twisted pair cabling. One further DTE or optical network component can be connected to the fiber port (with RS2- 4TX/1FX…). The TP ports support auto negotiation, autopolarity and autocrossing. The fiber optic ports support full duplex (FDX). RS2-xTX/xFX EEC Hirschmann. Simply a good Connection. 3 RS2-3TX/2FX +24V +24V* FAULT 2 3 4 LA1 LA3 LA2 LA4 LA5 0 1 DA/STAT 1 2 5 P 1 2 4 x 1 5 DA/STAT FAULT RS2-3TX/2FX EEC RS2-3TX/2FX-SM EEC 3 RS2-4TX +24V +24V* FAULT 2 3 4 LA1 LA3 LA2 LA4 0 1 DA/STAT 1 2 P 1 2 4 x 1 DA/STAT FAULT RS2-4TX EEC 3 RS2-4TX/1FX +24V +24V* FAULT 2 3 4 LA1 LA3 LA2 LA4 LA5 0 1 DA/STAT 1 2 5 P 1 2 4 x 1 5 DA/STAT FAULT RS2-4TX/1FX EEC RS2-4TX/1FX-SM EEC 3 RS2-4TX/1FX +24V +24V* FAULT 2 3 4 LA1 LA3 LA2 LA4 LA5 0 1 DA/STAT 1 2 5 P 1 2 4 x 1 DA/STAT FAULT RS2-4TX/1FX-ST EEC 5 039651002070706000

Upload: dcorso

Post on 09-Jul-2016

223 views

Category:

Documents


4 download

TRANSCRIPT

Description and operating instructionsIndustrial ETHERNET Rail Switch 2

The Rail Switches

– RS2-3TX/2FX EEC– RS2-3TX/2FX-SM EEC

– RS2-4TX/1FX EEC – RS2-4TX/1FX-ST EEC– RS2-4TX/1FX-SM EEC

– RS2-4TX EEC

in short RS2-xTX/xFX EEC, are switchesespecially designed for use in industrialenvironments. They support ETHERNET 10MBit/s and Fast ETHERNET 100 MBit/s.

The Rail Switch modules support switchedETHERNET networks in accordance withIEEE standard 802.3 using copper and fiberoptic technology. The switch modules areplugged onto the standard DIN rail.

The RS2-3TX/2FX… modules have three10/100 MBit/s twisted pair ports(10/100BASE-TX, RJ45 connectors) and two100 MBit/s fiber optic ports (100BASE-FX,Duplex SC connector).It is possible to connect up to three DTEs orother TP/TX network segments to the TP/TXports using twisted pair cabling. Two furtherDTEs or optical network components can beconnected to the fiber ports.

The RS2-4TX/1FX… modules have four10/100 MBit/s twisted pair ports(10/100BASE-TX, RJ45 connectors) and one100 MBit/s fiber optic port (100BASE-FX,Duplex SC connector or ST connector onR2-4TX/1FX-ST EEC).The RS2-4TX EEC module has four 10/100 MBit/s twisted pair ports(10/100BASE-TX, RJ45 connectors).It is possible to connect up to four DTEs orother TP/TX network segments to the TP/TXports using twisted pair cabling. One furtherDTE or optical network component can beconnected to the fiber port (with RS2-4TX/1FX…).

The TP ports support auto negotiation,autopolarity and autocrossing.

The fiber optic ports support full duplex(FDX).

RS2-xTX/xFX EEC

Hirschmann. Simply a good Connection.

3

RS2-3TX/2FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

5

DA/STATFAULT

RS2-3TX/2FX EEC

RS2-3TX/2FX-SM EEC

3

RS2-4TX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4

0 1

DA/STAT1 2P

1

2

4

x

1

DA/STATFAULT

RS2-4TX EEC

3

RS2-4TX/1FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

5

DA/STATFAULT

RS2-4TX/1FX EEC

RS2-4TX/1FX-SM EEC

3

RS2-4TX/1FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

DA/STATFAULT

RS2-4TX/1FX-ST EEC

5

039651002070706000

2

The performance features described hereare binding only if they have been expresslyguaranteed in the contract. We havechecked that the contents of the technicalpublication agree with the hardware andsoftware described. However, it is not possi-ble to rule out deviations completely, so weare unable to guarantee complete agree-ment. However, the details in the technicalpublication are checked regularly. Any cor-rections which prove necessary are contai-ned in subsequent editions. We are gratefulfor suggestions for improvement.

We reserve the right to make technicalmodifications.

Permission is not given for the circulationor reproduction of this document, its use orthe passing on of its contents unless gran-ted expressly. Contravention renders theperpetrator liable for compensation fordamages. All rights reserved, in particularin the case of patent grant or registration ofa utility or design.

Copyright © Hirschmann Automation and Control GmbH 2006All Rights Reserved

NoteWe would point out that the content ofthese operating instructions is not part of,nor is it intended to amend an earlier or exi-sting agreement, permit or legal relation-ship. All obligations on Hirschmann arisefrom the respective purchasing agreementwhich also contains the full warranty condi-tions which have sole applicability. Thesecontractual warranty conditions are neitherextended nor restricted by comments inthese operating instructions.

We would furthermore point out that forreasons of simplicity, these operatinginstructions cannot describe everyconceivable problem associated with theuse of this equipment. Should you requirefurther information or should particularproblems occur which are not treated insufficient detail in the operating instruc-tions, you can request the necessary infor-mation from your local Hirschmann salespartner or directly from the Hirschmannoffice (address: refer to chapter entitled„Notes on CE identification“).

Safety InstructionsThis manual contains instructions whichmust be observed to ensure your own per-sonal safety and to avoid damage to devices and machinery. Theinstructions are highlighted with a warningtriangle and are shown as follows according to the degree of endan-germent:

z Danger!means that death, serious injury orconsiderable damage to propertywill result if the appropriate safetymeasures are not taken.

z Warning!means that death, serious injury orconsiderable damage to propertycan result if the appropriate safetymeasures are not taken.

z Caution!means that light injury or damage toproperty can result if the appropria-te safety measures are not taken.

Note: is an important piece of informationabout the product, how to use the product,or the relevant section of the documentati-on to which particular attention is to bedrawn.

Certified usagePlease observe the following:

z WarningThe device may only be employedfor the purposes described in thecatalog and technical description,and only in conjunction with externaldevices and components recommen-ded or approved by Hirschmann.The product can only be operatedcorrectly and safely if it is transpor-ted, stored, installed and assembledproperly and correctly. Furthermore,it must be operated and servicedcarefully.

Safety GuidelinesPower Supply

� Switch the basic devices on only whenthe case is closed.

z Warning!The devices may only be connectedto the supply voltage shown on thetype plate.

The devices are designed for opera-tion with a safety extra-low volta-ge.Thus, they may only be connec-ted to the supply voltage connec-tions and to the signal contact withPELV circuits or alternatively SELVcircuits with the voltage restrictionsin accordance with IEC/EN 60950.

� For the case where the module is opera-ted with external power supply: Use only asafety extra-low voltage in accordance withIEC/EN 60950 to power the system.

� First of all you connect the protectingline, before you establish the furtherconnections. When you remove connec-tions, you disconnect the protecting linelast.

� Relevant for North America:The subject unit is to be suppplied by aClass 2 power source complying with therequirements of the National ElectricalCode, table 11(b). If power is redundantsupplied (two individual power sources) thepower sources together should comply withthe requirements of the National ElectricalCode, table 11 (b).

� Relevant for North America:Power, input and output (I/O) wiring mustbe in accordance with Class I, Division 2wiring methods [Article 501-4(b) of theNational Electrical Code, NFPA 70] and inaccordance with the authority having juris-diction.

Peripheral equipment must be suitable forthe location it is used in.

Use 60/75°C or 75°C copper(CU)wire only.

Safety GuidelinesShielding Ground

Note: The shielding ground of the connec-table twisted pairs lines is connected to thefront panel as a conductor.

� Beware of possible short circuits whenconnecting a cable section with conductiveshielding braiding.

Safety Guidelines Housing

z Warning!Only technicians authorized by Hir-schmann are permitted to open thehousing.

Note: The device is grounded via the sepa-rated ground screw. It is located on the leftunder the front panel.

� Make sure that the electrical installationmeets local or nationally applicable safetyregulations.

z Warning!The ventilation slits must not becovered so as to ensure free air cir-culation.

The distance to the ventilation slotsof the housing has to be a minimumof 10 cm.

Never insert pointed objects (thinscrewdrivers, wires, etc.) into theinside of the subrack! This especial-ly applies to the area behind thesocket connectors. Failure to obser-ve this point may result in injuriescaused by electric shocks.

Note: If installed in a living area or officeenvironment, the device must be operatedexclusively in switch cabinets with fire pro-tection characteristics according to EN60950.

Note: The housing has to be mounted inupright position.

Safety Guidelines Environment

z Warning!The device may only be operated inthe listed surrounding air tempera-ture and at the listed relative air humidity (non condensing).

� The installation location is to be selec-ted so as to ensure compliance with the cli-matic limits listed in the Technical Data.

� To be used in an up to Pollution Degree2 environment only (IEC 60664-1).

Staff qualificationrequirements

Note: Qualified personnel, as understoodin this manual and in the warning signs, arepersons who are familiar with the setup,assembly, startup, and operation of thisproduct and are appropriately qualified fortheir job. This includes, for example, thosepersons who have been:

3

– Germanischer Lloyd, rules for classifica-tion and constriction VI-7-3 part1 Ed.2001

Certified devices are marked with acertification identifier.

7Notes on CE identificationThe devices comply with the regula-tions of the following Europeandirective:

89/336/EECCouncil Directive on the harmoniza-tion of the legal regulations of mem-ber states on electromagnetic com-patibility (amended by Directives91/263/EEC, 92/31/EEC and93/68/EEC).

The EU declaration of conformity iskept available for the responsibleauthorities in accordance with theabove-mentioned EU directives at:

Hirschmann Automation and Control GmbH Stuttgarter Straße 45-51D-72654 NeckartenzlingenTelefon ++49-(0)1805-14-1538

The product can be used in the resi-dential sphere (residential sphere,business and trade sphere and smallcompanies) and in the industrialsphere.– Interference immunity:

EN 61000-6-2:2001– Radio interference level:

EN 55022:1998 + A1:2000 + A2:2003, Class A

z Warning!This is a Class A device. This equip-ment may cause radio interference ifused in a residential area; in thiscase it is the operator´s responsibili-ty to take appropriate measures.

The precondition for compliancewith EMC limit values is strict adhe-rence to the construction guidelinesspecified in this description andoperating instructions.

FCC Note:This equipment has been tested and foundto comply with the limits for a Class A digi-tal device, persuant to part 15 of the FCCRules. These limits are designed to providereasonable protection against harmful inter-ference when the equipment is operated ina commercial environment. This equipmentgenerates, uses, and can radiate radio fre-quency energy and, if not installed andused in accordance with the instructionmanual, may cause harmful interference toradio communications. Operation of thisequipment in a residential area is likely tocause harmful interference in which casethe user will be required to correct the inter-ference at his own expense.

– trained or directed or authorized toswitch on and off, to ground and to labelpower circuits and devices or systems inaccordance with current safety enginee-ring standards

– trained or directed in the care and use ofappropriate safety equipment in accor-dance with the current standards of safetyengineering

– trained in providing first aid.

General Safety Instructions� This device is electrically operated.Adhere strictly to the safety requirementsrelating to voltages applied to the device asdescribed in the operating instructions!

z Warning!Failure to observe the informationgiven in the warnings could result inserious injury and/or major damage.

Only personnel that have receivedappropriate training should operatethis device or work in its immediatevicinity. The personnel must be fullyfamiliar with all of the warnings andmaintenance measures in theseoperating instructions.

Correct transport, storage, andassembly as well as careful operati-on and maintenance are essential inensuring safe and reliable operationof this device.

Use only undamaged parts!

� These products are only to be used inthe manner indicated in this version of the”Description and Operating Instructions”.

� Particular attention is to be paid to allwarnings and items of information relatingto safety.

z Warning!Any work that may have to be per-formed on the electrical installationshould be performed by fully quali-fied technicians only.

z Warning!LED- or LASER components accor-ding to IEC 60825-1 (2001): CLASS 1 LASER PRODUCT. LIGHT EMITTING DIODE - CLASS 1LED PRODUCT.

Based specifications and standards:The devices fulfil the following specificati-ons and standards: – EN 61000-6-2:2001 Basic standard –

interference resistance in industry– EN 55022:1998 + A1:2000 + A2:2003 –

Interference characteristics for IT systems– EN 60950-1:2001 – Security in IT systems– EN 61131-2:2003 – Programmable Logic

Controllers– FCC 47 CFR Part 15:2004 – Code of Federal

Regulations– cUL 508:1998 – Safety for Industrial

Control Equipment– cUL 1604 Electrical Equipment for Use in

Class I and Class II, Div.2 and Class IIIHazardous (Classified) Locations

– cUL 60950 Safety for Information Technology Equipment.

,Recycling Note:After its use, this product has to beprocessed as electronic scrap anddisposed of according to the prevai-ling waste disposal regulations ofyour community / district / country /state.

4

1. Functional description

The 10/100BASE-T(X) ports of a RS2-xTX/xFX EEC represent a terminal connec-tion for the connected LAN segment. Youcan connect single devices or complete net-work segments.

1.1 FRAME SWITCHING FUNCTIONSStore and ForwardAll data received by the RS2-xTX/xFX EECfrom the system bus or at the ports is stored and checked for validity. Frames > 1536 bytes as well as fragments (< 64bytes) are discarded. The RS2-xTX/xFX EECforwards the valid frames.

Multi address capabilityA RS2-xTX/xFX EEC learns all sourceaddresses per port. Only packets with– unknown addresses– addresses learnt at this port– a multi/broadcast addressin the destination address field are sent tothis port.A RS2-xTX/xFX EEC learns up to 1,000addresses. This becomes necessary if morethan one terminal device is connected toone or more ports. In this way several inde-pendent subnetworks can be connected to aRS2-xTX/xFX EEC.

Learnt addressesA RS2-xTX/xFX EEC monitors the age of thelearned addresses. The RS2-xTX/xFX EECdeletes address entries from the addresstable which exceed a certain age (300seconds).Note: Restarting deletes the learnedaddress entries.

Tagging (IEEE 802.1Q)The IEEE 802.1 Q standard designates theVLAN tag to be included in a MAC dataframe for the VLAN and prioritizing func-tions. The VLAN tag consists of 4 bytes (2bytes tag protocol identifier TPID, 2 bytestag control information TCI). It is insertedbetween the source address field and thetype field. Data packets with a VLAN tag aretransmitted unchanged by the RS2-xTX/xFXEEC.

1.2 SPECIFIC FUNCTIONS OF THE TP/TX INTERFACELink controlThe RS2-xTX/xFX EEC monitors the connec-ted TP/TX line segments for short-circuits orinterrupts using regular Idle signals inaccordance with IEEE standard 802.310/100BASE-T/TX. The RS2-xTX/xFX EECdoes not transmit any data to a TP/TX seg-ment from which it does not receive an Idlesignal.

Note: A non-occupied interface is assessedas a line interrupt. The TP/TX line to termi-nal equipment which is switched off is like-wise assessed as a line interrupt as the de-energised bus coupler cannot transmit Idlesignals.

Auto polarity exchangeIf the receive line pair is incorrectly connec-ted (RD+ and RD- switched) polarity is auto-matically reversed.

AutocrossingThe RS2-xTX/xFX EEC detects the transmitand receive pairs (MDI, MDI-X). The RS2-xTX/xFX EEC automatically con-figures its port for the correct transmit andreceive pins. Consequently it does not matter whether you connect devices using a cross-over or straight cable.

1.3 SPECIFIC FUNCTIONS OF THEF/O INTERFACELink controlThe RS2-xTX/xFX EEC monitors the connec-ted F/O line for interrupts using idle signalsduring frame pauses in accordance withIEEE standard 802.3 100BASE-FX. The RS2-xTX/xFX EEC transmits no data to a F/Oline from which it is receiving no idle signal.

Low Light DetectionIf the optical input power decreases belowthe low light threshold the transmit andreceive path will be disabled for data andthe idle signal will be transmitted.

Far-End FaultThe optical transmission distance of theRS2-xTX/xFX EEC can be monitored inreceiving direction as well as in transmitting

direction, if the other side also supports Far-End Fault. If the other side does not supportFar-End Fault, the optical transmissiondistance is monitored only in receivingdirection.Far-End Fault is sent, if the optical inputpower at the optical port has fallen underthe low light level. If Far-End Fault is re-ceived, the link stays inactive (DA/STAT LEDdark).

1.4 FURTHER FUNCTIONS AND FEATURESResetThe RS2-xTX/xFX EEC will be reset by thefollowing action:– input voltages fall below a threshold

After a reset the following action is carriedout:– initialization

1.5 DISPLAY ELEMENTSEquipment statusThese LEDs provide information about sta-tuses which affect the function of the entireRS2-xTX/xFX EEC.P1 – Power 1 (green LED)– lit: – supply voltage 1 present– not lit: – supply voltage 1 less than 9.6 V

P2 – Power 2 (green LED)– lit: – supply voltage 2 present– not lit: – supply voltage 2 less than 9.6 V

FAULT (Red LED)– lit: – Indicator contact indica-

tes an error – not lit: – no error

Port StatusThese LEDs display port-related informa-tion.DA/STAT 1 to 5, DA/STAT 1 to 4 (on RS2-4TX EEC)– Data, Link status (green LED)– not lit: – no valid link– flashes: – data activity– lit: – valid link

Fig. 1: Overview display elements and interfaces of the RS2-xTX/xFX EEC

3

RS2-3TX/2FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

5

DA/STATFAULT

RS2-3TX/2FX EEC

RS2-3TX/2FX-SM EEC

3

RS2-4TX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4

0 1

DA/STAT1 2P

1

2

4

x

1

DA/STATFAULT

RS2-4TX EEC

3

RS2-4TX/1FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

5

DA/STATFAULT

RS2-4TX/1FX EEC

RS2-4TX/1FX-SM EEC

3

RS2-4TX/1FX

+24V

+24V

*

FAUL

T

2 3 4

LA1

LA3LA2

LA4LA5

0 1

DA/STAT1 2

5P

1

2

4

x

1

DA/STATFAULT

RS2-4TX/1FX-ST EEC

5-pin pluggable terminal block

LED display elements

5-pin DIP switch

3 Ports in line with 10/100BASE-T(X)

(RJ45 connectors)

According to product type:

- up to 1 port in line with 10/100BASE-T(X)

(RJ45 connector)

- up to 2 ports in line with 100BASE-FX

(Duplex SC or ST connector)

full duplex

All ports: autonegotiation, autopolarity

and autocrossing

5

5

– Pin configuration of the RJ45 socket,RS2-xTX/xFX EEC:– 1 line pair: pin 3 and pin 6– 1 line pair: pin 1 and pin 2– remaining pins: not used.

Fig. 3: Pin configuration of a TP/TX interface

100 Mbit/s connection (FX port)The 100 MBit/s ports of the RS2-xTX/xFX EEC,- one port on the RS2-4TX/1FX…- two ports on the RS2-3TX/2FX… supportthe IEEE 802.3 100BASE-FX FDX standard.They use a duplex SC connector or a STconnector (on RS2-4TX/1FX-ST EEC). Each100 MBit/s port allows one further DTE oran optical network component to beconnected.

5pin terminal blockThe supply voltage and the indicatorcontact are connected via a 5pin terminalblock. If the terminal block is fitted thewrong way round, the device will still workcorrectly.

z Warning!The RS2-xTX/xFX EEC equipmentsare designed for operation with asafety extra-low voltage. Thus, theymay only be connected to the sup-ply voltage connections with PELVcircuits or alternatively SELV circuitswith the voltage restrictions inaccordance with IEC/EN 60950.

Pin 8Pin 7Pin 6Pin 5Pin 4Pin 3Pin 2Pin 1

Fig. 2: Display elements of the RS2-xTX/xFX EEC

1.6 INTERFACES10/100 MBit/s connection (TP port)The 10/100 Mbit ports of the RS2-xTX/xFXEEC (8-pin shielded R45 sockets),- three ports on the RS2-3TX/2FX…- four ports on the RS2-4TX/1FX…allow DTEs or independent network seg-ments complying with the standards IEEE802.3 100BASE-TX / 10BASE-T to beconnected. These ports support autonego-tiation, the autopolarity function andautocrossing.

The socket casings are electrically connec-ted to the front panel of the RS2-xTX/xFXEEC.

LEDs for power

(P1 and P2)

LEDs for data, link status

(DA/STAT 1 to 5)

FAULT

LED

LEDs for power

(P1 and P2)

LEDs for data, link status

(DA/STAT 1 to 5)

on the RS2-4TX EEC

FAULT

LED

2 3 4DA/STAT1 2P 1

DA/STATFAULT

2 3 4DA/STAT1 2

5P 1

DA/STATFAULT

– Voltage supply: Redundant voltage sup-plies are supported. Both inputs aredecoupled. There is no load distribution.With redundant supply, the power packsupplies the RS2-xTX/xFX EEC only withthe higher output voltage. The supply vol-tage is electrically isolated from the hou-sing.

Fig. 5: Pin configuration of 5 pin terminalblock

– Indicator contact: The indicator contact is used to supervisethe functions of the RS2-xTX/xFX EEC andthus facilitates remote diagnosis withoutmanagement software.Contact interrupt indicates the followingby means of a potential-free indicatorcontact (relay contact, closed circuit):– the failure of at least one of the two

supply voltages (supply voltage 1 or 2 < 9.6 V).

– a permanent fault in the RS2-xTX/xFXEEC (internal voltage supply).

– the faulty link status of at least one port.The indication of the link state on theRS2-xTX/xFX EEC can be masked on aport-by-port basis using the DIP swit-ches LA1 to LA5 (LA1 to LA4 on RS2-4TX EEC).State of delivery: link test is activated.

+24V

+24V

*

FAUL

T

= 0V

Fig. 4: Configuration with RS2-xTX/xFX EEC: Connection of up to 4 data terminal equipments (4 on RS2-4TX/1FX…, 3 on RS2-3TX/2FX…)or further segments via TP/TX as well as connection via fiber optic cable with up to 2 optical ports (1 on RS2-4TX/1FX…, 2 on RS2-3TX/2FX….

robot

userstation

PLC

I/O block

100 Mbit/sHIPER-Ring

100 Mbit/s

10 Mbit/s

RS2-FX/FX RS2-FX/FX

RS2-TXRS2-4TX/1FX

RS2-3TX/2FX

RS2-3TX/2FX

x

RS2-4TX/1FX

x

6

Ground connectionThe RS2-xTX/xFX EEC is grounded via aseparate screw connection.

1.7 CONTROLS5-pole DIP switch (Suppressing the link states)With a DIP switch on the front panel of theRS2-xTX/xFX EEC the indication of the linkstates by the indicator contact can be sup-pressed port by port. Using the switchesLA1 to LA5 (LA1 to LA4 on RS2-4TX EEC),the indication of the link states can be sup-pressed. Switch position „ON“: the indication of thelink state is not suppressed, that is the indi-cator contact indicates the unvalid link.State of delivery: LA1 to LA5 (LA1 to LA4 on RS2-4TX EEC) in position „ON“ (position 1).

Fig. 6: 5-pole DIP switch to suppress theindication of the link states

2. Configuration

2.1 CONNECTING DTE AND OTHERNETWORK SEGMENTSIt is possible to connect up to three DTEs orother TP/TX network segments to the10/100 Mbit/s ports of the RS2-3TX/2FX…using twisted pair cabling. Two further dataterminal equipments or optical networkcomponents can be connected at 100 Mbit/sto the optical ports using fiber optic cable.It is possible to connect up to four DTEs orother TP/TX network segments to the10/100 Mbit/s ports of the RS2-4TX/1FX…using twisted pair cabling. One further dataterminal equipment or optical network com-ponent can be connected at 100 Mbit/s tothe optical port using fiber optic cable. It is possible to connect up to four DTEs orother TP/TX network segments to the10/100 Mbit/s ports of the RS2-4TX EECusing twisted pair cabling.(ref. Fig. 4).

LA1

0 1

LA3

LA2

LA4

Port 1

Port 3

Port 2

Port 4

Suppress message

about link status

via indicator contact

(RS2-4TX EEC)

LA1

0 1

LA5

LA3

LA2

LA4

Port 1

Port 5

Port 3

Port 2

Port 4

Suppress message

about link status

via indicator contact

(RS2-*TX/*FX(-SM) EEC)

3. Assembly, startup procedureand dismantling

3.1 UNPACKING, CHECKING� Check whether the package was deliver-ed complete (see scope of delivery).� Check the individual parts for transportdamage.

z Warning!Use only undamaged parts!

3.2 ASSEMBLYThe equipment is delivered in a ready-to-operate condition. The following procedureis appropriate for assembly:

� Pull the terminal block off the RS2-xTX/xFX EEC and wire up the supply volta-ge.� Fit the RS2-xTX/xFX EEC on a 35 mmstandard DIN rail to DIN EN 50 022.� Attach the upper snap-on slide bar ofthe RS2-xTX/xFX EEC to the standard DINrail and press it down until it locks into posi-tion.� Fit the signal lines.

Notes:– The front panel of the RS2-xTX/xFX EEC is

grounded via a separate ground connec-tion.

– Do not open the housing.

– The shielding ground of the twisted paircables is electrically connected to the frontpanel.

Fig. 7: Assembling the RS2-xTX/xFX EEC

3.3 STARTUP PROCEDURE� You start up the RS2-xTX/xFX EEC byconnecting the supply voltage via the 5-pinterminal block.

3.4 DISMANTLING� To take the RS2-xTX/xFX EEC off theISO/DIN rail, insert a screwdriver horizontal-ly under the housing into the locking slide,pull it (without tipping the screwdriver)downwards and lift the RS2-xTX/xFX EECupwards.

4. Further support

In the event of technical queries, please talkto the Hirschmann contract partner respon-sible for looking after your account or direc-tly to the Hirschmann office. You can findthe addresses of our contract partners– on the internet

http://www.hirschmann-ac.com

Our support line is also at your disposal:Tel. +49(1805) 14-1538Fax +49(7127) 14-1551

Answers to Frequently Asked Questions canbe found on the Hirschmann product site www.hirschmann-ac.com

The FAQs are located under „Service“ inthe Automation and Network Solutions sec-tion.

www.hicomcenter.com gives you an up-to-date overview of training courses abouttechnology and products.

7

5. Technical data

General data

Operating voltage NEC Class 2 power source 24 VDC (-25% +33%) safety extra-low voltage (SELV/PELV) (redundant inputs decoupled), 5 A maximum

Buffer time min. 10 ms at 24 VDC

Potential difference between input Potential difference to input voltage, +24 VDC: 32 VDCvoltage and housing Potential difference to input voltage, ground: -32 VDC

Power comsumption at 24 VDCRS2-3TX/2FX EEC 5.9 W maximum; 21 Btu (IT)/hRS2-3TX/2FX-SM EEC 5.9 W maximum; 21 Btu (IT)/hRS2-4TX EEC 4.8 W maximum; 17 Btu (IT)/hRS2-4TX/1FX EEC 5.4 W maximum; 19 Btu (IT)/hRS2-4TX/1FX-ST EEC 5.4 W maximum; 19 Btu (IT)/hRS2-4TX/1FX-SM EEC 5.4 W maximum; 19 Btu (IT)/h

Overload current protection at input non-changeable fuseDimensions W x H x D 47 mm x 135 mm x 111 mmMass RS2-3TX/2FX…: 335g

RS2-4TX/1FX…: 330gRS2-4TX EEC: 300g

Ambient temperature Surrounding air -40°C to +70°C (expanded temperature bounds)Storage temperature Surrounding air -40°C to +85°C (expanded temperature bounds)Humidity up to 95% (non condensing)Atmospheric pressure suitable for use in up to 2000 m (795 hPa, higher altitudes on demand)Laser protection Class 1 conforming to EN 60825-1Protection type IP 20Interference proof EMC

Discharge of static electricityContact discharge EN 61000-4-2 Test level 3Air discharge EN 61000-4-2 Test level 3

Electromagnetic fields EN 61000-4-3 Test level 3Fast transients EN 61000-4-4 Test level 3Surge voltage symmetrical EN 61000-4-5 Test level 2Surge voltage asymmetrical EN 61000-4-5 Test level 3Cable-based RF faults EN 61000-4-6 Test level 3

Radiated emission EMCEN 55022 Class AFCC 47 CFR Part 15 Class A

StabilityVibration IEC 60068-2-6 Test FC, testing level in line with EN 61131-2:2003Shock IEC 60068-2-27 Test Ea, testing level in line with EN 61131-2:2003

Network size

TP/TX port 10BASE-T/100BASE-TXLength of a twisted pair segment 100 m (328 ft) maximumF/O port 100BASE-FXAccording to IEEE 802.3u 100BASE-FX System attenuation

50/125 µm fiber (multimode MM) 0 to 8 dB62,5/125 µm fiber (multimode MM) 0 to 11 dB9/125 µm fiber (singlemode SM) 0-16 dB (…-SM)

Wave length 1300 nm (…-SM)

F/O line length (example)50/125 µm fiber (multimode MM) 5 km approx. (data of fiber: 1.0 dB/km, 800 MHz*km)62,5/125 µm fiber (multimode MM) 4 km approx. (data of fiber: 1.0 dB/km, 500 MHz*km)10/125 µm fiber (singlemode SM) 30 km (98,420 ft) maximum (…-SM) (data of fiber: 0,4 dB/km)

InterfacesRS2-3TX/2FX… 3 TP/TX ports RJ45 sockets, 10/100 MBit/s

2 FX ports Duplex SC connector, 100 MBit/sRS2-4TX/1FX EEC, RS2-4TX/1FX-SM EEC 4 TP/TX ports RJ45 sockets, 10/100 MBit/s

1 FX port Duplex SC connector, 100 MBit/sRS2-4TX/1FX-ST EEC 4 TP/TX ports RJ45 sockets, 10/100 MBit/s

1 FX port ST connector, 100 MBit/sRS2-4TX EEC 4 TP/TX ports RJ45 sockets, 10/100 MBit/s

Displays

Equipment status 1 x green LED P1 – power 1, supply voltage 1 present1 x green LED P2 – power 2, supply voltage 2 present1 x red LED FAULT – indicator contact indicates an error

Port status 5 x green LED DA/STAT 1 to 5 – data, link status (on RS2-xTX/xFX…)4 x green LED DA/STAT 1 to 4 – data, link status (on RS2-4TX EEC)

Hirschmann Automation and Control GmbHStuttgarter Straße 45-51D-72654 NeckartenzlingenGermanyTel.: ++49 / 1805 / 14-1538Fax: ++49 / 7127 / 14-1551E-Mail: [email protected]: http://www.hirschmann.com

Printed in GermanySubject to alterations

Scope of delivery

Rail Switch RS2-xTX/xFX EEC incl.terminal block for supply voltagedescription and operating instructions

Order numberRail Switch RS2-3TX/2FX EEC 943 771-001Rail Switch RS2-3TX/2FX-SM EEC 943 772-001Rail Switch RS2-4TX EEC 943 819-001Rail Switch RS2-4TX/1FX EEC 943 773-001Rail Switch RS2-4TX/1FX-ST EEC 943 119-002Rail Switch RS2-4TX/1FX-SM EEC 943 774-001

Accessories

ETHERNET manual 943 320-011ManualBasics Industrial ETHERNET and TCP/IP 280 720-834Rail Power Supply RPS 30 943 662-003Rail Power Supply RPS 60 943 662-001Rail Power Supply RPS 120 943 662-011