an pe. intellectual property which belongs to …the fey residence installation of a roof mount...

2
3 8 - 16 X 3 4 HEX HEAD BOLT 3/8-16 FLANGE BOLT PV MODULE SERRATED L ROOF MOUNT HOLD DOWN ANCHOR RE: NOTES PV CLAMP WATER PROOFING EXIST. ASP SHINGLES SOLAR MOUNT RAIL EXISTING RAFTERS EXIST. DECKING PZ2 =4'-0" PZ2 =4'-0" GABLE PZ3 PZ3 PZ1 RIDGE EAVE DN 4/12 +/-54'-4" V.I.F. #8296 GUMTREE AVE 1 STORY SINGLE FAMILY RESIDENCE ASP SHINGLE ROOF SLOPE 4/12 MOUNTING RAIL (TYP) 33'-8" PV ARRAY LENGTH 4'-0" 30'-4" PV ARRAY LENGTH SHEET NO: PUBLISHED: SHEET NAME: DRAWN: CHECKED: SB AG ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/0344.ST.Fey_NewPortRichey_FL.dwg REVISIONS: 01 SCALE: N.T.S. PARCEL - (AHJ PROPERTY APPRAISER) 02 SCALE: 3"=1'-0" TYP. ATTACHMENT DETAIL I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL. CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWN HERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THE ARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADING OF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION! COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF OWNER OF RECORD: 8926 GUM TREE AVE,NEW PORT RICHEY FL 34653 Y JOSEPH & SUSAN C THIS PLAN IS ONLINE FOR REVIEW @ WWW.GEZELMANPE.COM/PV/0344.ST.FEY_NEWPORTRICHEY_FL.PDF CONTACT DESIGN GROUP @ www.GezelmanPE.com ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE FBC2010 INSTALLATION OF A ROOF MOUNT RENEWABLE ENERGY SYSTEM THE FEY RESIDENCE VULT: 140 MPH, VSAD 108 MPH EXPOSURE: B RISK CATEGORY: II GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN 4PSF UPLIFT(PSF) : PZ1-16.7, PZ2-28.7 PZ3 -43 CODE VERIFY MODULE# SW270M/250M FSEC: SW12-NT90-0409 DESIGNED PER: ASCE 7-10, FBC 2010 07 SCALE: 3/16" = 1'-0" SOLAR ARRAY ROOF LAYOUT WITH 19 PV MODULES WIND 03 SCALE: NTS STREET VIEW OF INSTALLATION LOCATION PASCO COUNTY, PARCEL ID# 18E17S320060 02480 0260 SITUS: 8926 GUM TREE AVE,NEW PORT RICHEY FL 34653 PRESSURE ZONES 2 = 4'-0" WIDE: 04 SCALE: NTS OEM RACKING - UNIRAC PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES: THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN AS STATED ON THE DRAWING. ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC (SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION. THE SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED. THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 5/16TH INCH DIAMETER CORROSION RESISTANT STEEL. THESE HOLD-DOWNS SHALL BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOP CORD OF TRUSSES. PRESSURE ZONE (PZ) #2 WIDTH IS 4-FT. PV ARRAY TO BE INSTALLED PRIMARILY WITHIN PZ1. MOUNTING RAILS SHALL BE ANCHORED INTO ROOF STRUCTURAL FRAMING AT CENTER-TO-CENTER DISTANCES NOT TO EXCEED PZ1 6-FT C-C; PZ2 4-FT C-C. THERE SHALL BE NO USE OF PZ3 WITH THE LAYOUT SHOWN ELSEWHERE ON THIS PLAN. HOWEVER, IF JOBSITE CIRCUMSTANCES REQUIRE INTRUSION INTO PZ3, C-C ROOF ATTACHMENT SPACING (WITHIN PZ3) SHALL BE 2-FT +- TO HIT TRUSSSES. THERE SHALL BE TWO PIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. THE PV MODULES SHALL BE INSTALLED IN THE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTED IN THE ELECTRICAL LAYOUT OF THIS SUBMITTAL. THERE SHALL BE FOUR CLAMPS HOLDING EACH MODULE TO THE RAILS. THESE SHALL BE PAIRED OPPOSITES. ADJACENT MODULES MAY SHARE CLAMPS. PV MODULES MAY BE ORIENTED “LANDSCAPE” OR “PORTRAIT” AT THE CONTRACTOR'S OPTION. WATER-PROOFING: CONTRACTOR SHALL USE OEM FLASHING SHOWN ON PAGE 9 OF OEM INSTALLATION GUIDE HTTP://WWW.SOLARWORLD-USA.COM/~/MEDIA/WWW/FILES/INSTALL-GUIDES/SUNFIX-PLUS-INSTALLATION-GUIDE.PDF ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NO ROOF LEAKS AT TIME OF INSTALLATION AND AS THE SYSTEM “AGES”. ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS. 5/5/14 CONTRACTOR: LSCI, INC. D.B.A. SUNTEC 19321-C US HWY 19 N STE. 500 CLEARWATER, FL 33764 PH: 727-571-4141 HTTP://SUN-TEC-FL.COM/ QUICKMOUNT FLASHING MAY BE USED AT CONTACTORS CHOICE 06 SCALE: NTS PV MODULE SPECIFICATIONS INSTALLATION LOCATION INSTALLATION LOCATION 05 SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS SAMPLE INSTALLATION PHOTOS DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAIL HTTP://WWW.UNIRAC.COM/RESIDENTIAL/RESIDENTIAL-PRODUCTS/SOLAR-MOUNT-RESIDENTIAL# UNIRAC CODE COMPLIANT LETTER - FLORIDA: 08 SCALE: NTS (http://www.quickmountpv.com) QUICKMOUNT FLASHING (OPTIONAL)

Upload: others

Post on 02-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AN PE. INTELLECTUAL PROPERTY WHICH BELONGS TO …the fey residence installation of a roof mount renewable energy system vult: 140 mph, vsad 108 mph ... system to be installed at the

38 - 16 X 34 HEX HEAD BOLT3/8-16 FLANGE BOLT

PV MODULE

SERRATED LROOF MOUNT

HOLD DOWN ANCHOR RE: NOTES

PV CLAMP

WATER PROOFING

EXIST. ASP SHINGLES

SOLAR MOUNT RAIL

EXISTINGRAFTERS

EXIST. DECKING

PZ2 =4'-0"

PZ2 =4'-0"

GA

BLE

PZ3

PZ3

PZ1

RIDGE

EAVE

DN

4/1

2

+/-54'-4" V.I.F.

#8296 GUMTREE AVE1 STORY SINGLE FAMILY RESIDENCE

ASP SHINGLE ROOF SLOPE 4/12

MOUNTING RAIL (TYP)

33'-8" PV ARRAY LENGTH

4'-0"

30'-4" PV ARRAY LENGTH

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

KA

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E

AC

CE

SS

ED

AT

: W

WW

.GE

ZE

LMA

NP

E.C

OM

/PV

/0

34

4.S

T.F

ey

_N

ew

Po

rtR

ich

ey_

FL.

dw

g

REVISIONS:

01SCALE: N.T.S.

PARCEL - (AHJ PROPERTY APPRAISER)02

SCALE: 3"=1'-0"

TYP. ATTACHMENT DETAIL

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC

C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC

C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

OWNER OF RECORD:

8926 GUM TREE AVE,NEW PORT RICHEY FL 34653

Y JOSEPH & SUSAN C THIS PLAN IS ONLINE FOR REVIEW @WWW.GEZELMANPE.COM/PV/0344.ST.FEY_NEWPORTRICHEY_FL.PDF

CO

NT

AC

T D

ES

IGN

GR

OU

P @

ww

w.G

eze

lma

nP

E.c

om

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THEFBC2010

INS

TA

LLA

TIO

N O

F A

RO

OF

MO

UN

T

RE

NE

WA

BLE

EN

ER

GY

SY

ST

EM

TH

E F

EY

RE

SID

EN

CE

VULT: 140 MPH, VSAD 108 MPH

EXPOSURE: B

RISK CATEGORY: II GRAVITY LOAD FROM SOLAR EQUIPMENT LESS THAN 4PSF

UPLIFT(PSF) : PZ1-16.7, PZ2-28.7 PZ3 -43

CO

DE

VE

RIF

Y

MODULE# SW270M/250M FSEC: SW12-NT90-0409

DESIGNED PER: ASCE 7-10, FBC 2010

07SCALE: 3/16" = 1'-0"

SOLAR ARRAY ROOF LAYOUT WITH 19 PV MODULES

WIN

D

03SCALE: NTS

STREET VIEW OF INSTALLATION LOCATION

PASCO COUNTY, PARCEL ID# 18E17S320060 02480 0260

SIT

US

: 8

92

6 G

UM

TR

EE

AV

E,N

EW

PO

RT

RIC

HE

Y F

L 3

46

53

PRESSURE ZONES 2 = 4'-0" WIDE:

04SCALE: NTS

OEM RACKING - UNIRAC

PHOTO-VOLTAIC SOLAR ENERGY SYSTEM INSTALLATION NOTES:THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE ESSENTIAL INFORMATION

NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION) AND INSTALLERS. USERS ARE ENCOURAGED TO

ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN AS STATED ON THE DRAWING. ACTIVE HYPERLINKS ONEV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TOSTUDY THE PLAN AND OEM DETAILS AT MAGNIFICATIONS OF VIEWER CHOICE UP TO 6400%. IF A

CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL,OEM SHALL PREVAIL. THIS PLAN GIVES SITE-SPECIFIC INSTALLATION DETAILS FOR A PHOTOVOLTAIC

(SOLAR ELECTRIC) SYSTEM TO BE INSTALLED AT THE ABOVE LOCATION.

THE SOLAR MODULES SHALL BE THE NUMBER, MAKE AND MODEL LISTED.

THE HOLD DOWN ANCHORS SHALL BE (MINIMUM) 5/16TH INCH DIAMETER CORROSION RESISTANT STEEL.THESE HOLD-DOWNS SHALL BE LAGS ACHIEVING 3-INCH THREAD EMBEDMENT IN TOP CORD OF TRUSSES.

PRESSURE ZONE (PZ) #2 WIDTH IS 4-FT. PV ARRAY TO BE INSTALLED PRIMARILY WITHIN PZ1. MOUNTINGRAILS SHALL BE ANCHORED INTO ROOF STRUCTURAL FRAMING AT CENTER-TO-CENTER DISTANCES NOTTO EXCEED PZ1 6-FT C-C; PZ2 4-FT C-C. THERE SHALL BE NO USE OF PZ3 WITH THE LAYOUT SHOWNELSEWHERE ON THIS PLAN. HOWEVER, IF JOBSITE CIRCUMSTANCES REQUIRE INTRUSION INTO PZ3, C-C

ROOF ATTACHMENT SPACING (WITHIN PZ3) SHALL BE 2-FT +- TO HIT TRUSSSES. THERE SHALL BE TWOPIECES OF SPECIFIED RACKING UNDER EACH PV MODULE. THE PV MODULES SHALL BE INSTALLED INTHE NUMBER OF PARALLEL STRINGS AND NUMBER OF SERIES PV MODULES IN EACH STRING AS DEPICTEDIN THE ELECTRICAL LAYOUT OF THIS SUBMITTAL. THERE SHALL BE FOUR CLAMPS HOLDING EACH MODULETO THE RAILS. THESE SHALL BE PAIRED OPPOSITES. ADJACENT MODULESMAY SHARE CLAMPS. PV MODULES MAY BE ORIENTED “LANDSCAPE” OR “PORTRAIT” AT THECONTRACTOR'S OPTION.WATER-PROOFING:

• CONTRACTOR SHALL USE OEM FLASHING SHOWN ON PAGE 9 OF OEM INSTALLATION GUIDEHTTP://WWW.SOLARWORLD-USA.COM/~/MEDIA/WWW/FILES/INSTALL-GUIDES/SUNFIX-PLUS-INSTALLATION-GUIDE.PDF

ADHERE TO MEANS & METHODS OF NRCA ROOFING & WATERPROOFING MANUAL TO ENSURE NOROOF LEAKS AT TIME OF INSTALLATION AND AS THE SYSTEM “AGES”. ADHERE TO ALL APPLICABLE BUILDING CODE REQUIREMENTS.

5/5/14

CONTRACTOR:

LSCI, INC. D.B.A. SUNTEC19321-C US HWY 19 N STE. 500CLEARWATER, FL 33764

PH: 727-571-4141

HTTP://SUN-TEC-FL.COM/

QUICKMOUNT FLASHING MAY BE USED ATCONTACTORS CHOICE

06SCALE: NTS

PV MODULE SPECIFICATIONS

INSTALLATION LOCATIONINSTALLATION LOCATION

05SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS

SAMPLE INSTALLATION PHOTOS

DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAIL

HTTP://WWW.UNIRAC.COM/RESIDENTIAL/RESIDENTIAL-PRODUCTS/SOLAR-MOUNT-RESIDENTIAL#

UNIRAC CODE COMPLIANT LETTER - FLORIDA:

08SCALE: NTS (http://www.quickmountpv.com)

QUICKMOUNT FLASHING (OPTIONAL)

Siggi
Snapshot
Page 2: AN PE. INTELLECTUAL PROPERTY WHICH BELONGS TO …the fey residence installation of a roof mount renewable energy system vult: 140 mph, vsad 108 mph ... system to be installed at the