ams-02 magnetic field measurement prof. chin e. lin, ncku, tnn tim jan. 09, 2007

32
AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Upload: melinda-cameron

Post on 29-Jan-2016

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-02 Magnetic Field Measurement

Prof. Chin E. Lin, NCKU, TNNTIM Jan. 09, 2007

Page 2: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-02 Magnetic Field

• AMS-02 magnetic field measurement to identify the interior magnetic field by a servo system in planar scanning

• The exterior magnetic field is only identified by some specified locations

Page 3: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture Design Concept

Page 4: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Actual Fixture on Mockup

Page 5: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture Tests

• We use wooden mock-up to carry on our calibration test and field measurement test at NCKU

Page 6: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Mount Support on Mock-up

Page 7: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture on Mock-up in NCKU

Page 8: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture on AMS-01

Sensor in position

Page 9: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture on AMS-01

Sensor position

calibration

Hall Sensor

Hall Sensor

Page 10: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Magnetic Field Sensor

• We use a SYPRIS Co. F. W. BELL Model 7030 Gauss/Tesla Meter, with 3D probe for 300 k Gauss( 30 Tesla) in 1 m Gauss( 0.1 μ Tesla) resolution

Page 11: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Origin Calibration

• Use laser pointer on both X and Y axes to project an intersection to identify as its origin of probe scanning

Page 12: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Origin Calibration• Laser positioning calibration

Page 13: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Field Mapping

• AMS-02 magnetic field mapping will run a little more than one quarter of the overall interior volume, assuming the field distribution is x- and y- symmetrical.

• Initially, we need to identify the symmetry by a few symmetrical locations

• The servo system is controlled to run only one quarter. Otherwise, we have to do full plane mapping.

Page 14: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Mapping Plane

Page 15: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Where to Mount

• On the original design, we found from the four mounting holes to use.

• However, currently, the temp O-ring has four seal attachments using the same mounting holes.

• Can they be shifted ?

Page 16: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture Mounting

Page 17: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Temp O-Ring

Page 18: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Considering O-Ring

• We reduce the planar size to consider the temporary O-ring. The scanning distance is 80 mm less in diameter.

• The scanning control software is adjustable to fit for O-ring.

Page 19: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Measurement in SCL

• We try to finish the AMS-02 interior field measurement within 7 days

• We need to prepare 1-2 days before mounting on to AMS-02

• The fixture is about 500 lbs. We need help by a crane to lift it up.

Page 20: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture Shipping

• The measurement fixture shipping to Oxford takes 6-8 weeks.

• We will be ready anytime from today.

Page 21: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-01 Tests

Page 22: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture on AMS-01 Tests

• We have used the measurement fixture to finish AMS-01 magnetic field measurement.

Page 23: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Fixture on AMS-01

Page 24: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-01 Field Measurement

Page 25: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

A

Page 26: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-01 Data in Memory

• Data acquisition from measurement system and store into database

Page 27: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Measurement Axis

Page 28: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

A

• A

Page 29: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

AMS-01 Magnetic Field Profile

Page 30: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

Exterior Measurement

• Due to CSIST site constraint where AMS01 is located, we can only measure half spherical for less than 2 meters outside the main body

• From an axis, locating at 120 degree, to both side with each step of 15 degree, at 1 meter and 1.5 meter from top to down

Page 31: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

A

• A

Page 32: AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

A

• A