INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Control Valve.

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

I/P Converter Readings Control Valve Open/Close (%)

InputmA

ActualOutput

Kg/Sqcm

ObservedOutput

Kg/SqcmDeviation

Actual%

Observed%

Deviation Remarks

Forward

4 0

8 25

12 50

16 75

20 100

Reverse

20 100

16 75

12 50

8 25

4 4

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Pressure Transmitter

Project : Aishwarya Field Development Project. Model No. :

Location : Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Pressure Transmitter ReadingsRemarksPressure

Applied( )

Actual Output in

mA.

ObservedOutput in

mA

Transmitter Display

( ) Error

Forward

48121620

Reverse

20161284

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Loop Powered Indicator

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Loop Powered Indicator Reading

Input mA

Desired Display(KpaG)

Actual Display(KpaG)

Error Remarks

Forward

48121620

Reverse

20161284

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Differential Pressure Transmitter

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Differential Pressure Transmitter ReadingsRemarksPressure

Applied( )

Actual Output in

mA.

ObservedOutput in

mA

Transmitter Display Error

Forward

48121620

Reverse

20161284

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Flow Transmitter

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Flow Transmitter ReadingsRemarksPressure

Applied( )

Actual Output in

mA.

ObservedOutput in

mA

Transmitter Display Error

Forward

48121620

Reverse

20161284

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Level Transmitter

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Level Transmitter ReadingsRemarksPressure

Applied( )

Actual Output in

mA.

ObservedOutput in

mA

Transmitter Display Error

Forward

48121620

Reverse

20161284

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Temperature Transmitter

Project : Aishwarya Field Development Project. Model No. :

Location : AWP-08 Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Temperature Transmitter ReadingsRemarksResistance

AppliedΩ

Actual Output in

mA.

ObservedOutput in

mA

Transmitter Display

> CError

Forward

48121620

Reverse

20161284

Remarks: …………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date

INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2

Document Name: Calibration Report for Pressure Gauge

Project : Aishwarya Field Development Project. Model No. :

Location : Service :

Tag No : Serial No. :

Range : Accuracy :

Master Equipment Details

Make/Inst.Type :

Model No. :

Sr. No :

Accuracy :

Certificate No :

Valid Up to :

Pressure Gauge

Pressure Applied

( )

Actual Reading ( )

ObservedReading ( )

Error Remarks

Remarks: ………………………………………………………………………………………………

……………………………………………………………………………………………………………

Calibrated By TPL FQE CIL

Sign

Name

Date