instrument calibration test report format
DESCRIPTION
Instrument Calibration Test Report FormatTRANSCRIPT
![Page 1: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/1.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Control Valve.
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
I/P Converter Readings Control Valve Open/Close (%)
InputmA
ActualOutput
Kg/Sqcm
ObservedOutput
Kg/SqcmDeviation
Actual%
Observed%
Deviation Remarks
Forward
4 0
8 25
12 50
16 75
20 100
Reverse
20 100
16 75
12 50
8 25
4 4
![Page 2: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/2.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Pressure Transmitter
Project : Aishwarya Field Development Project. Model No. :
Location : Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Pressure Transmitter ReadingsRemarksPressure
Applied( )
Actual Output in
mA.
ObservedOutput in
mA
Transmitter Display
( ) Error
Forward
48121620
Reverse
20161284
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 3: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/3.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Loop Powered Indicator
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Loop Powered Indicator Reading
Input mA
Desired Display(KpaG)
Actual Display(KpaG)
Error Remarks
Forward
48121620
Reverse
20161284
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 4: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/4.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Differential Pressure Transmitter
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Differential Pressure Transmitter ReadingsRemarksPressure
Applied( )
Actual Output in
mA.
ObservedOutput in
mA
Transmitter Display Error
Forward
48121620
Reverse
20161284
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 5: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/5.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Flow Transmitter
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Flow Transmitter ReadingsRemarksPressure
Applied( )
Actual Output in
mA.
ObservedOutput in
mA
Transmitter Display Error
Forward
48121620
Reverse
20161284
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 6: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/6.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Level Transmitter
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Level Transmitter ReadingsRemarksPressure
Applied( )
Actual Output in
mA.
ObservedOutput in
mA
Transmitter Display Error
Forward
48121620
Reverse
20161284
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 7: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/7.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Temperature Transmitter
Project : Aishwarya Field Development Project. Model No. :
Location : AWP-08 Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Temperature Transmitter ReadingsRemarksResistance
AppliedΩ
Actual Output in
mA.
ObservedOutput in
mA
Transmitter Display
> CError
Forward
48121620
Reverse
20161284
Remarks: …………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date
![Page 8: Instrument Calibration Test Report Format](https://reader036.vdocuments.mx/reader036/viewer/2022082321/55cf966a550346d0338b5622/html5/thumbnails/8.jpg)
INSTRUMENT CALIBRATION TESTING RECORDFORM NO. : A204TPL-AISH-IC-REP 0909 REV. A2
Document Name: Calibration Report for Pressure Gauge
Project : Aishwarya Field Development Project. Model No. :
Location : Service :
Tag No : Serial No. :
Range : Accuracy :
Master Equipment Details
Make/Inst.Type :
Model No. :
Sr. No :
Accuracy :
Certificate No :
Valid Up to :
Pressure Gauge
Pressure Applied
( )
Actual Reading ( )
ObservedReading ( )
Error Remarks
Remarks: ………………………………………………………………………………………………
……………………………………………………………………………………………………………
Calibrated By TPL FQE CIL
Sign
Name
Date