installation guide - harmoni · installation guide installation guide electronic intelligent timer...
Post on 15-May-2018
326 Views
Preview:
TRANSCRIPT
installation guide
installation guide
electronic intelligent timer thermostat
www.harmonithermostat.co.uk
2
installation guide
Contents
Page
1 Introduction ....................................................... 3
1.1 Technicalspecifications............................... 4
1.2 SafetyInstructions....................................... 7
2 Mounting Instructions ....................................... 8
3 Settings ............................................................. 12
3.1 Initialsettings...............................................12
3.2 Forecast......................................................16
3.3 Windowopen..............................................18
3.4 Maximumfloortemperature........................19
4 Symbols ............................................................. 23
5 Disposal Information ......................................... 24
6 Warranty ............................................................ 24
More information on this product can be found at: www.harmoni-stat.co.uk
3
harmoni 50
Introduction 1
harmoni 50isanelectronicprogrammabletimerthermostat usedforcontrollingelectricalunderfloorheatingelements.
Thethermostatisdesignedforfixedinstallationonly.Itcanbeusedforbothdirectheatingoftheentireroomandforcomfortheatingofthefloor.Listedbelowaresomeofthethermostat’smainfeatures:
h Atouchscreendisplaywithbacklight.
h Easy-to-followmenu-drivenprogrammingandoperation.
h Aninstallationwizardwithroom/floortypespecificset-up.
h Supportformultipleframesystems.
h Compatiblewithnumerous3rdpartyNTCsensors.
h Settingscanbecopiedfromonethermostattoanother/othersusingasinglegeneratedcode.
4
installation guide
TechnicalSpecifications 1.1
Operation voltage 220–240 V~
Standby power consumption Max. 0.40 W
Relay: Resistance load Inductive load
Max. 16 A / 3680 W @ 230 V cos φ= 0.3 Max. 1 A
Sensing units NTC 6.8 kOhm at 25°C NTC 10 kOhm at 25°C NTC 12 kOhm at 25°C NTC 15 kOhm at 25°C (default) NTC 33 kOhm at 25°C NTC 47 kOhm at 25°C
Sensing values: (default NTC 15 K) 0°C 20°C50°C
42 kOhm 18 kOhm 6 kOhm
Control PWM (Pulse Wide Modulation)
Ambient temperature 0° to +30°C
Frost protection temperature 5°C to +9°C (default 5°C)
5
harmoni 50
Temperature range Room temperature 5–35°C. Floor temperature 5–45°C. Max. floor: 20–35°C (if unrecoverable seal is broken then up to 45°C). Min. floor: 10–35°C, only with combination of room and floor sensor.
Sensor failure monitoring The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or short-circuited.
Cable specification max. 1×4mm² or 2×2.5mm²
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
6
installation guide
IP class 21
Protection class Class II –
Dimensions 85×85×20–24mm (in-wall depth: 22mm)
Weight 103g
TechnicalSpecifications 1.1
Electricalsafetyandelectro-magneticcompatibilityforthisproductiscoveredbythecompliancewiththeEN/IECStandard,Automatic electrical controls for household and similar use:
h EN/IEC60730-1(general)
h EN/IEC60730-2-9(thermostat)
7
harmoni 50
SafetyInstructions 1.2
Makesurethemainssupplytothethermostatisturnedoffbeforeinstallation.
Important: Whenthethermostatisusedtocontrolafloorheatingelementinconnectionwithawoodenfloororsimilarmaterial,alwaysuseafloorsensorandneversetthemaximumfloortemperaturetomorethan35°C.
Please also note the following:
h Theinstallationofthethermostatmustbedonebyanauthorisedandqualifiedinstalleraccordingtolocalregulations.
h Thethermostatmustbeconnectedtoapowersupplyviaanall-poledisconnectionswitch.
h Alwaysconnectthethermostattocontinuouspowersupply.
h Donotexposethethermostattomoisture,water,dustandexcessiveheat.
8
installation guide
Mounting Instructions 2
Pleaseobservetheplacementguidelinesbelow.
Placethethermostatatasuitableheightonthewall(typically80–170cmfromthefloor).
Thethermostatshouldnotbeplacedinwetrooms,placeitinanadjacentroominstead.Wheninstallingthethermostatoutsidetheroomitshouldbein‘floorsensoronly’mode.AlwaysplacethethermostataccordingtolocalregulationsonIPclasses.
Donotplacethethermostatontheinnersideofanexteriorwall.
Alwaysinstallthethermostatatleast50cmfromwindowsanddoors.
9
harmoni 50
Donotplacethethermostatinaplacethatisexposedtodirectsunlight.
Important: Afloorsensorenablesamoreaccuratetemperaturecontrolandisrecommendedinallfloorheatingapplicationsandiscompulsoryunderwoodenfloorstoreducetheriskofoverheatingthefloor.
h Placethefloorsensorinaconduitinanappropriateplacewhereitisnotexposedtosunlightordraftfromdooropenings.
h Equallydistantand>2cmfromtwoheatingcables.
h Theconduitshouldbeflushwiththefloorsurface;countersinktheconduitifnecessary.
h Routetheconduittotheconnectionbox.
h Thebendingradiusoftheconduitmustbeaminimumof50mm.
10
installation guide
Mounting Instructions 2
Follow the steps below to mount the thermostat.
1.Openthethermostat.
Important:DoNOTpressonthedisplayscreen whenremovingthefrontpart.
Pressyourfingersunderthesideofthefrontpart andgentlypullitaway.
2.Connectthethermostat accordingtothe connectiondiagram.
Thescreenoftheheating cablemustbeconnected totheearthconductorof thepowersupplycableby usingaseparateconnector.
harmoni Standby maximum 0.4W
NT NL NLC
Maximum Load 16 (1) A
Mains 220-240V–50-60 HzS
enso
r
LOAD
LOAD
IP21T30
11
harmoni 50
Important: Alwaysinstallthefloorsensorin aconduitinthefloor.
3.Mountandreassemblethethermostat.
h Fixthethermostattoasocketoranexteriorwallboxusingthescrewholesineachsideofthethermostat.
h Reattachtheframe.
h Clickthedisplaymodulebackinplace.
Important: DoNOTpressonthedisplay screenwhenclickingthedisplaymoduleback in place.
Initially,fullychargethethermostatbatteryusingthemainssupplyfor15hours.Thecurrenttimeanddayisthenkeptfor24hoursifmainssupplyisswitchedoff.Allothersettingsarestoredpermanently.
12
installation guide
Settings 3
InitialSettings 3.1Initial settings must be specified when the unit is activated for the first time.
1.Thelanguageissetto Englishbydefault.
2.Pressthehournumbers usingthe< and >arrowsto setthehour.Press to confirm.
3.Presstheminutenumbers usingthe< and >arrowsto settheminutes.Press to confirm.Press againtogo totheSET DATEscreen.
SET TIME
14:56
LANGUAGE
English
13
harmoni 50
4.Presstheday,monthand yearandsetthedateusing the< and >arrows, pressing toconfirm. Whenthedateiscorrect, press toconfirmonthe SET DATEscreen.
5.PressSETUP WIZARD and go to Step 6.
Note:Ifyouhavealready setonethermostatand needtocopythesesettings toanotherone(ormore), pressSETTINGS. Press INFOthenREAD OUT. Writedownthegenerated codeandgodirectly to Step 13 (page 16) now.
SET DATE
31:01:12
READ OUT
10B1-0F57-A845-41FE
TIME/DATE SETTINGS
TIMER AWAY
12:52 16.10.13
14
installation guide
6.OntheSETUPinformation screenpress tostart.
7.Usethe< and >arrowsto selectwhetheronlyafloor sensororacombinationof roomandfloorsensors shouldbeused.Press toconfirm. Note:A‘roomonly’option mayalsobeavailable.See Maximum Floor Temperature on page 20.
8.Usethe< and >arrowsto selecttheinstalledfloor sensortype(measured resistance&corresponding temperatureareshownin brackets).Press to confirm.
SENSOR TYPE
3/7
15K STANDARD (14.5kΩ 25.18°)
SETUP
1/7
InitialSettings 3.1
WALK THROUGH THE
FOLLOWINGSTEPS. PRESS
CONTROL
2/7
ROOM + FLOOR
15
harmoni 50
9. Usethe< and >arrows toselecttheflooringtype. Press toconfirm.
10.Usethe< and >arrows toselecttheroomtype. Press toconfirm.
11.Usethe< and >arrowsto settheapproximateload oftheheatingelement.Ifan externalrelayisusedorthe installedoutputisunknown, selectthe‘--’option. Press toconfirm.
FLOORING
4/7
TILES
OUTPUT [W]
6/7
450
ROOM TYPE
5/7
BATHROOM
16
installation guide
InitialSettings 3.1
12.Usethe< and >arrows toselectwhetherthetimer shouldbeactivatedornot. Press toconfirmand endtheinitialthermostat setup.Skip Step 13.
13.PressSETTINGSthen INSTALLATION.Press ENTER CODE. Keyinyourgenerated code(no spaces or hyphens).Press toend theinitialthermostatsetup. Ifnocheckmark( ) appears,thegenerated codeisincorrect.
TIMER
7/7
OFF
ENTER CODE
0 1 2 3 4 5 6 7 8 9 a b c d e f clr del
17
harmoni 50
Forecast 3.2
When Forecastisturnedon,heatingwillstartearliersotherequiredtemperatureisreachedatthespecifiedtime.
Forexample,ifyourcomforttemperatureissetto22°C andthetimerissetto6am,thetemperaturewillbe22°Cat6am.However,ifForecastisswitchedoff,heating won’tstartuntil6amandwilltakeawhiletoreach22°C.
The Forecastfeaturealsooptimisesheatingstopwhenswitchingfromcomforttoeconomytemperature.
How to turn the Forecast feature on and off.
21.5menu
1.Touchthethermostat displaytoactivateit, thenpressmenu
2.PressSETTINGSinthe bottomrightcornerofthe menu.PressOPTIONS.
TIME/DATE SETTINGS
TIMER AWAY
12:52 16.10.13
18
installation guide
3. PressFORECAST.
4. PressONtooptimise heatingstart/stop.
OrpressOFFtosimplylet theheatingstart/stopat thespecifiedtime. Press toconfirm
Note:Toreturntothenormaltemperaturedisplay, pressthebackarrow( )intheupperleftcorner ofthescreenuntilyougettothemainmenu.Press thehome( )symbolinthemiddleofthescreen.
Forecast 3.2
FORECAST
ON / OFF
OPTIONS
SAFETY LOCK
FORECAST
DIM LEVEL
FORECASTTIMER AWAY
19
harmoni 50
21.5menu
TIME/DATE SETTINGS
TIMER AWAY
12:52 16.10.13
WindowOpen 3.3
WINDOW
ON / OFF
How to turn ‘window open detection’ on or off.
1. Touchthethermostatdisplay toactivateit.Pressmenu.
2.PressSETTINGS inthe bottomrightcornerofthe menu.PressOPTIONS.
3.PressWINDOW OPEN. PressONtotemporarily turnoffheatingincaseof asuddentemperaturedrop intheroomorOFFtolet thethermostatheatup,also duringsuddentemperature dropsintheroom.Press toconfirm.
Note:Toreturntothenormaltemperaturedisplay, see note on page 18.
20
installation guide
MaximumFloorTemperature 3.4
21.5menu
How to set the maximum floor temperature.
1. Touchthethermostatdisplay toactivateit.Pressmenu.
2.PressSETTINGS inthe bottomrightcornerof themenu.Press INSTALLATIONS and MANUAL SETUP.
3.PressMAX. FLOOR. Usethe< and >arrows tosettheallowed maximumfloortemperature. Press toconfirm.
Note:Toreturntothenormaltemperaturedisplay, see note on page 18.
MAX. FLOOR
35.0
TIME/DATE SETTINGS
TIMER AWAY
12:52 16.10.13
21
harmoni 50
Ifyoubreakthesmallplasticsealonthebackofthedisplaymodule(eg,usingascrewdriver),it'spossibletosetthemaximumfloortemperatureto45°C.Itwouldalsobepossibletouseonlyaroomsensor.However,thisisn'trecommendedduetoanincreasedriskofoverheatingthefloor.
Important: Whenthethermostatisusedtocontrolafloorheatingelementinconnectionwithawoodenfloor orsimilarmaterial,alwaysuseafloorsensorandnever setthemaximumfloortemperaturetomorethan35°C.
Note:Pleasecontactthefloorsupplierbeforealteringthe maximumfloortemperatureandbeawareofthefollowing:
h Thefloortemperatureismeasuredwherethesensoris placed.
h Thetemperatureatthebottomofawoodenfloorcanbeupto10degreeshotterthanthetop.
h Floormanufacturersoftenspecifythemaximumtemperatureonthetopsurfaceofthefloor.
22
installation guide
Thermal resistance (m2K/W)
Examples of flooring Details Approx. setting for 25°C floor temperature
0.05 8mm HDF based laminate
< 800 kg/m³
28°C
0.10 14mm beech parquet 650–800 kg/m³
31°C
0.13 22mm solid oak plank > 800 kg/m³
32°C
< 0.17 Max. carpet thickness suitable for floor heating
acc. to EN 1307
34°C
0.18 22mm solid fir planks 450–650 kg/m³
35°C
MaximumFloorTemperature 3.4
23
harmoni 50
Symbols 4
Thesymbolsshownbelowmayappearintheupperleftcornerofthetemperaturedisplay:
Symbol Meaning
Thethermostatisinmanualmode,ie,thetimerfunctionisoff.Thetimerletsyouautomaticallyswitchbetweeneconomyandcomforttemperaturesaccordingtoapredefinedschedule.
Anawayperiodhasbeenplanned.Onthedateofdeparture,theawayperiodstartsat00:00andthespecifiedawaytemperaturewillbemaintained24hoursadayuntilthedateofreturnat00:00.Atthistimethenormaltemperaturesettingswillresume.
Anerrorhasoccurred.Ifyoupressthewarningsymbol,moreinformationontheerrorwillappear.
harmoni Standby maximum 0.4W
NT NL NLC
Maximum Load 16 (1) A
Mains 220-240V–50-60 HzS
enso
r
LOAD
LOAD
IP21T30
harmoni Standby maximum 0.4W
NT NL NLC
Maximum Load 16 (1) A
Mains 220-240V–50-60 HzS
enso
r
LOAD
LOAD
IP21T30
harmoni Standby maximum 0.4W
NT NL NLC
Maximum Load 16 (1) A
Mains 220-240V–50-60 HzS
enso
r
LOAD
LOAD
IP21T30
24
installation guide
Warranty 6
Theharmoni50thermostatcomeswitha5-yearwarrantyasstandard.
Disposal Information 5
25
harmoni 50
Warranty 6
Name.............................................................................
Address .........................................................................
.......................................................................................
County.....................................Postcode........................
Address..........................................................................
Phone.............................................................................
Email..............................................................................
Please note Inordertoobtaintheharmoniwarranty,anauthorisedelectrician/installermustfillinthedetailsbelow.
Electrician Installation/installer..........................................date ....................
Thermostat Articlename.............................................number................
Stamp:
26
installation guide
Notes
27
harmoni 50
Notes
installation guide
harmoni EdisonHouse EdisonClose RansomesEuropark Ipswich SuffolkIP39GU UnitedKingdom
T:01473559088 F:01473276678 E:sales@harmonithermostat.co.uk
www.harmonithermostat.co.uk
harmoni cannot accept any responsibility for any errors in catalogues, brochures and other printed material. harmoni reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes to specifications already agreed. All trademarks in this material are the property of harmoni. harmoni and the harmoni logotype are trademarks of Edison House Ltd. All rights reserved.