ECOFLOOR

TRAINING

HEATING CABLE TYPES

SINGLE-CORD CABLES*: DOUBLE-CORD CABLES**:

- SCREEN PROTECTION:

- WITHOUT SCREEN PROTECTION:

- SCREEN PROTECTION:

ASL1P

MPSV

PSV

PV

ADSV

ADPSP

MADPSP

* 2 x cold connection leads ** Only 1 x cold connection lead

HEATING CABLE TYPES

ADSV:

1 - DOUBLE-CORD CABLE

2 – FULL SCREEN PROTECTION (14 tinned copper wires 0,3 mm + AlPET foil) 3 - FEP INSULATION

4 - PVC JACKET

EL.CONNECTION:

1 x 3m COLD CONNECTION LEAD

1

1

2

3

4

ADSV USING - RECOMMENDATION

DIRECT HEATING (UNDER TILES):

WET/NOT WET AREAS (BATHROOMS, KITCHENS, HALLS, ETC..):

JUST INDOOR APPLICATION

NEW BUILDINGRECONSTRUCTION

ADSV STANDARD PRODUCTS

1.HEATING CABLES ADSV / ADSV-T ON DRUMS (SEMI-FINISHED PRODUCTS)

2.HEATING CABLE CIRCUITS (heating cable ADSV with 1connection lead)

ADSV STANDARD PRODUCTS

3.HEATING MATS

Double-sided adhesive tape

LDTS

ADSV (ADSV-T) STANDARD PRODUCTS

HEATING MATS LDTSPacking

Mat in carton box

ADSV (ADSV-T) STANDARD PRODUCTS

SELF-ADHESIVE MATS LSDTS Packing

Mat in carton box

ADSV STANDARD PRODUCTS

4.INSTALLATION SETS

ECOFLOOR Cable Kit

ADSV (ADSV-T) STANDARD PRODUCTS

INSTALLATION SETS

ECOFLOOR Comfort Mat

DIA (mm): 3,6-4,6

MIN. CABLE LOOPS SPACING (mm): 40

MAX.LINEAR POWER (W/m): 18

IN CASE OF SURFACE POWER HIGHER THAN 160W/m2 IS NECESSARY TO SET FOLLOWING MAX.FLOOR PROBE TEMP.(°C):

35

MAX.CABLE JACKET TEMP.(°C): 80

MAX. FIRST CABLE INSULATION TEMP.(°C): 120

ADSVTECHNICAL DATA

ADSV

ADSVPRODUCT RANGES

ADSV (ADSV-T*)

PRODUCTS MARKING STANDARD OFFER

STANDARD APPLICATION

Linear

Power

W/m

Surface

Power W/m2

Direct

Heating

Storage

Heating

Cable circuit ADSV10x

ADSV15x

ADSV18x

10

15

18

X

Mat LDTS8x-105*

LDTS12x-165*

100

160

X

Installation

Set

E.CableKit

E.ComfortMat*

10

160, 100

X

X

Heating cable circuits ADSV

INSTALLATION FOR DIRECT FLOOR HEATING

ECOFLOOR

Packing Variant

EHC Box

DIRECT FLOOR HEATING

NEW BUILDING

RECONSTRUCTION

Prevents heat losses to the sub-floor – recommendation during floor reconstruction!

F-BOARD

ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Fixing of el. junction

6. Installation of Heating cable circuit

7. Control measuring

8. Thin layer flexible cementing (glueing)

9. New tiling

Heating cable fixing accessories:

A. Cable fixing on concrete base floor

GRUFAST Fixing strip

ADHESIVE TAPE

B. Cable fixing on previous tiles floor (Reconstruction)

Measure total area to be heated, then order kit

Remember

Always keep cable at least 50mm away from wall

Use the spacing template provided in the kit to mark out the floor

0.5 m²

4 m² .25 m²

Bathroom area to be heated is 4.75 m², heated at 160 watts /m²

Kit 10 – 750 required (covers 4.7 m²)

Total area is: 4.75 m²

ECOFLOOR Cable Kit installation

Cut the groove for the floor probe and install the flexible pipe

Begin laying the cable taping it to the floor as you go

Test the cable for resistance and then cover with tile adhesive

Test the cable for resistance once tiling is complete

Tile and grout

ECOFLOOR Cable Kit installation

Heating mat LDTS

INSTALLATION FOR DIRECT FLOOR HEATING

ECOFLOOR

LDTS Heating mat (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Heating mat laying

6. Mat sticking to the floor base by its self-

adhesive tape

7. Control measuring

8. Thin layer flexible cementing (glueing)

9. New tiling

6. Heating mat installation

ECOFLOOR Comfort Mat

LDTS mat handling

INSTALLATION NOTICE

minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm.

the heating cable may never be shortened or

cutted !!! (only the cold connection

lead)

NO!

INSTALLATION NOTICE

• Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm

the connector (junction) between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!)

the heating cable may never pass over an expansion joint

For floor heating are suitable following thermostats:

TH 132-AF

Eberle FR-E 52531

Eberle Instat 8

TEMPERATURE CONTROLS

Fenix Therm 100

16 Amps thermostat connection (thermostat with floor probe)

L – phase (el.supply)

N – neutral (el.supply)

L’ –phase (Ecofloor)

N’ – neutral (Ecofloor)

Electrical installation directly throught the thermostat

Electrical installation throught the el.box and contactor(1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)

HEATING CABLE TYPES

ADPSP:

1 - DOUBLE-CORD CABLE2 - FEP INSULATION

4 - FULL SCREEN PROTECTION (PET/AL foil + copper wires)

3 - XLPE INSULATION

EL.CONNECTION:

1 x 5m COLD CONNECTION LEAD

5 – PVC jacket (UV protection)

2

5

1

34

4 1

ADPSP USING - RECOMMENDATION

REMOVING ICE AND SNOW FROM ROOFS AND

GUTTERS

AS A PROTECTION OF PIPES AGAINST FREEZING

JUST OUTDOOR APPLICATION

ADPSP

STANDARD PRODUCTS

1.HEATING CABLES ADPSP (HALF-FINISHED PRODUCTS)

2.HEATING CABLE CIRCUITS (heating cable ADPSP with 1connection lead)

ADPSP ECOFLOOR Heating Cable

DIA (mm): 5,0-5,9

MIN. CABLE LOOPS SPACING (mm): 40

MAX.LINEAR POWER (W/m): For roofs and gutters

For pipes

Technologic heating

20

10

15

MAX.CABLE JACKET TEMP.(°C): 80

MAX. FIRST CABLE INSULATION TEMP.(°C): 120

ADPSPTECHNICAL DATA

ADPSP

ADPSPPRODUCT OFFER

ADPSP

PRODUCTS MARKING STANDARD OFFER

STANDARD APPLICATION

Linear

Power

W/m

Surface

Power W/m2

Roofs and

gutters

Protection of

pipes

Cable circuit ADPSP 10x

ADPSP 20x

10

20

X

X

Mat

Installation

Set

TEMPERATURE CONTROLS

Eberle EM 52487Snow and ice sensor ESD 524003Heat sensor ESD 524004

Heating of eaves troughs and gutters

Heating of pipes and tubes

Eberle ITR-3 UTR/60

sensors

ANOTHER ECOFLOOR

APPLICATIONS

INDOOR APPLICATION

SEMI-STORAGE AND STORAGE HEATING:

WET AREAS (BATHROOMS, LAUNDRIES, ETC..):

NOT WET AREAS (KITCHENS, HALLS, LIVING ROOMS, ETC..):

PSV

PV

MPSV

MADPSP

OUTDOOR APPLICATION

OUTDOOR SURFACE WARMING

MPSV

MADPSP

SPECIAL APPLICATION

GRASS WARMING ON FOOTBALL STADIUM

MADPSP

Contact us : FENIX Trading s.r.o.