Page 1: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ECOFLOOR

TRAINING

Page 2: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

HEATING CABLE TYPES

SINGLE-CORD CABLES*: DOUBLE-CORD CABLES**:

- SCREEN PROTECTION:

- WITHOUT SCREEN PROTECTION:

- SCREEN PROTECTION:

ASL1P

MPSV

PSV

PV

ADSV

ADPSP

MADPSP

* 2 x cold connection leads ** Only 1 x cold connection lead

Page 3: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

HEATING CABLE TYPES

ADSV:

1 - DOUBLE-CORD CABLE

2 – FULL SCREEN PROTECTION (14 tinned copper wires 0,3 mm + AlPET foil) 3 - FEP INSULATION

4 - PVC JACKET

EL.CONNECTION:

1 x 3m COLD CONNECTION LEAD

1

1

2

3

4

Page 4: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV USING - RECOMMENDATION

DIRECT HEATING (UNDER TILES):

WET/NOT WET AREAS (BATHROOMS, KITCHENS, HALLS, ETC..):

JUST INDOOR APPLICATION

NEW BUILDINGRECONSTRUCTION

Page 5: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV STANDARD PRODUCTS

1.HEATING CABLES ADSV / ADSV-T ON DRUMS (SEMI-FINISHED PRODUCTS)

2.HEATING CABLE CIRCUITS (heating cable ADSV with 1connection lead)

Page 6: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV STANDARD PRODUCTS

3.HEATING MATS

Double-sided adhesive tape

LDTS

Page 7: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV (ADSV-T) STANDARD PRODUCTS

HEATING MATS LDTSPacking

Mat in carton box

Page 8: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV (ADSV-T) STANDARD PRODUCTS

SELF-ADHESIVE MATS LSDTS Packing

Mat in carton box

Page 9: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV STANDARD PRODUCTS

4.INSTALLATION SETS

ECOFLOOR Cable Kit

Page 10: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV (ADSV-T) STANDARD PRODUCTS

INSTALLATION SETS

ECOFLOOR Comfort Mat

Page 11: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

DIA (mm): 3,6-4,6

MIN. CABLE LOOPS SPACING (mm): 40

MAX.LINEAR POWER (W/m): 18

IN CASE OF SURFACE POWER HIGHER THAN 160W/m2 IS NECESSARY TO SET FOLLOWING MAX.FLOOR PROBE TEMP.(°C):

35

MAX.CABLE JACKET TEMP.(°C): 80

MAX. FIRST CABLE INSULATION TEMP.(°C): 120

ADSVTECHNICAL DATA

ADSV

Page 12: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSVPRODUCT RANGES

ADSV (ADSV-T*)

PRODUCTS MARKING STANDARD OFFER

STANDARD APPLICATION

Linear

Power

W/m

Surface

Power W/m2

Direct

Heating

Storage

Heating

Cable circuit ADSV10x

ADSV15x

ADSV18x

10

15

18

X

Mat LDTS8x-105*

LDTS12x-165*

100

160

X

Installation

Set

E.CableKit

E.ComfortMat*

10

160, 100

X

X

Page 13: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Heating cable circuits ADSV

INSTALLATION FOR DIRECT FLOOR HEATING

ECOFLOOR

Packing Variant

EHC Box

Page 14: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

DIRECT FLOOR HEATING

NEW BUILDING

RECONSTRUCTION

Page 15: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Prevents heat losses to the sub-floor – recommendation during floor reconstruction!

F-BOARD

Page 16: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:
Page 17: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Fixing of el. junction

6. Installation of Heating cable circuit

7. Control measuring

8. Thin layer flexible cementing (glueing)

9. New tiling

Page 18: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Heating cable fixing accessories:

A. Cable fixing on concrete base floor

GRUFAST Fixing strip

ADHESIVE TAPE

B. Cable fixing on previous tiles floor (Reconstruction)

Page 19: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Measure total area to be heated, then order kit

Remember

Always keep cable at least 50mm away from wall

Use the spacing template provided in the kit to mark out the floor

0.5 m²

4 m² .25 m²

Bathroom area to be heated is 4.75 m², heated at 160 watts /m²

Kit 10 – 750 required (covers 4.7 m²)

Total area is: 4.75 m²

ECOFLOOR Cable Kit installation

Page 20: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Cut the groove for the floor probe and install the flexible pipe

Begin laying the cable taping it to the floor as you go

Test the cable for resistance and then cover with tile adhesive

Test the cable for resistance once tiling is complete

Tile and grout

ECOFLOOR Cable Kit installation

Page 21: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Heating mat LDTS

INSTALLATION FOR DIRECT FLOOR HEATING

ECOFLOOR

Page 22: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

LDTS Heating mat (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Heating mat laying

6. Mat sticking to the floor base by its self-

adhesive tape

7. Control measuring

8. Thin layer flexible cementing (glueing)

9. New tiling

6. Heating mat installation

Page 23: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ECOFLOOR Comfort Mat

Page 24: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

LDTS mat handling

Page 25: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

INSTALLATION NOTICE

minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm.

the heating cable may never be shortened or

cutted !!! (only the cold connection

lead)

NO!

Page 26: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

INSTALLATION NOTICE

• Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm

the connector (junction) between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!)

the heating cable may never pass over an expansion joint

Page 27: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

For floor heating are suitable following thermostats:

TH 132-AF

Eberle FR-E 52531

Eberle Instat 8

TEMPERATURE CONTROLS

Fenix Therm 100

Page 28: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

16 Amps thermostat connection (thermostat with floor probe)

L – phase (el.supply)

N – neutral (el.supply)

L’ –phase (Ecofloor)

N’ – neutral (Ecofloor)

Page 29: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Electrical installation directly throught the thermostat

Page 30: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

Electrical installation throught the el.box and contactor(1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)

Page 31: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

HEATING CABLE TYPES

ADPSP:

1 - DOUBLE-CORD CABLE2 - FEP INSULATION

4 - FULL SCREEN PROTECTION (PET/AL foil + copper wires)

3 - XLPE INSULATION

EL.CONNECTION:

1 x 5m COLD CONNECTION LEAD

5 – PVC jacket (UV protection)

2

5

1

34

4 1

Page 32: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADPSP USING - RECOMMENDATION

REMOVING ICE AND SNOW FROM ROOFS AND

GUTTERS

AS A PROTECTION OF PIPES AGAINST FREEZING

JUST OUTDOOR APPLICATION

Page 33: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADPSP

STANDARD PRODUCTS

1.HEATING CABLES ADPSP (HALF-FINISHED PRODUCTS)

2.HEATING CABLE CIRCUITS (heating cable ADPSP with 1connection lead)

ADPSP ECOFLOOR Heating Cable

Page 34: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

DIA (mm): 5,0-5,9

MIN. CABLE LOOPS SPACING (mm): 40

MAX.LINEAR POWER (W/m): For roofs and gutters

For pipes

Technologic heating

20

10

15

MAX.CABLE JACKET TEMP.(°C): 80

MAX. FIRST CABLE INSULATION TEMP.(°C): 120

ADPSPTECHNICAL DATA

ADPSP

Page 35: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ADPSPPRODUCT OFFER

ADPSP

PRODUCTS MARKING STANDARD OFFER

STANDARD APPLICATION

Linear

Power

W/m

Surface

Power W/m2

Roofs and

gutters

Protection of

pipes

Cable circuit ADPSP 10x

ADPSP 20x

10

20

X

X

Mat

Installation

Set

Page 36: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

TEMPERATURE CONTROLS

Eberle EM 52487Snow and ice sensor ESD 524003Heat sensor ESD 524004

Heating of eaves troughs and gutters

Heating of pipes and tubes

Eberle ITR-3 UTR/60

sensors

Page 37: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

ANOTHER ECOFLOOR

APPLICATIONS

Page 38: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

INDOOR APPLICATION

SEMI-STORAGE AND STORAGE HEATING:

WET AREAS (BATHROOMS, LAUNDRIES, ETC..):

NOT WET AREAS (KITCHENS, HALLS, LIVING ROOMS, ETC..):

PSV

PV

MPSV

MADPSP

Page 39: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

OUTDOOR APPLICATION

OUTDOOR SURFACE WARMING

MPSV

MADPSP

Page 40: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION:

SPECIAL APPLICATION

GRASS WARMING ON FOOTBALL STADIUM

MADPSP

Page 41: ECOFLOOR TRAINING HEATING CABLE TYPES SINGLE-CORD CABLES*:DOUBLE-CORD CABLES**: - SCREEN PROTECTION: - WITHOUT SCREEN PROTECTION: - SCREEN PROTECTION: