CONGRATULATIONS

ON YOUR NEW

COCHRAN EMC-20H

DIVE COMPUTER

Cochran Undersea Technology a division of Cochran Consulting, Inc.Copyright 2000 - 2002 All rights reserved, Protected under one or more

Patents, Patents Pending, or Trademarks.

PLEASE SELECT THE PRESENTATIONYOU WOULD LIKE TO VIEW FROM

THE BUTTONS BELOW.

AIR ONLY

1-MIX NITROX

2-MIX NITROX

EXIT

1-MIX PO2

2-MIX PO2

THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC

FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE

AIR ONLY COCHRAN EMC-20H.

PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.

ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

SIDE CONTACTS:

Locate the three side contacts.

TURN ME ON

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE

BLADE, AND YOUR FINGER.

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT

WATER, FRESH WATER, AND YOUR WET FINGER.

Contact #3

Contact #2

Contact #1

SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET

FINGER ACTIVATES THE UNIT.

A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

Contact #2

Contact #1

THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”

ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-

TEST WHEN SUCCESSFULLY COMPLETED.

DI

VE

B AT T

N D CD E C

ASC

TNE

D E P T HM A XB O T TO M

C E ILT E M PW A R N I N GR E M A IN T IM E F LY

S U R F D E P T HM E T R IC

. .

UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE.

T E M P

S U R F

ASC

TNE

THE SURFACE INTERVAL SCREEN IS VISIBLE WHENEVER THE UNIT IS AWAKE AND ON THE

SURFACE.

IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY

ADDITIONAL INFORMATION.

Maximum Depth(of the last dive)

Air Temperature

Bottom Time(of the last dive)

Surface Time(Amount of timesince last dive)

Time to Fly(Hours beforesafely flying)

Dive of “Day”(Repetitive Dive

Number)

AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT

DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS.

ALTITUDE APPEARS IN THE ASCENT BAR GRAPH

T E M P

S U R F

ASC

TNE

Air Temperature

Surface TimeBarometric

Altitude (2500 feetper bar

No bars = 0 - 25002 bars = 5000 - 7500)

IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT AUTOMATICALLY GOES TO SLEEP TO

CONSERVES BATTERY POWER.

LET’S GO DIVING

AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES

OTHER PROGRAMMING AND DISPLAY MODES.

IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY

POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF.

CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

DURING A DIVE, THE FOLLOWING

DATA IS AVAILABLE IN A LARGE, EASY

TO READ DISPLAY.

Water Temperature

N D CASC

TNE

B O T TO M

T E M PR E M A IN T IM E

D E P T HM A XD E P T H

Maximum Depth(so far this dive)

Current DepthBottom Time(so far this dive)

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

Ascent Rate(1 bar = 10-19 fpm)

Note NDC Legend

DIVE MODE

A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES.

THE REMAIN TIME NUMBERS FLASH

THE WARNING LEGEND APPEARS AND FLASHES

AN AUDIBLE ALARM WILL BE ISSUED

SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE

DECOMPRESSION MODE.

DEC

DEPTHMAXBOTTOM

CEILREMAIN TIME

DEPTH

STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL

CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

COCHRAN DOES NOT INTEND FOR THIS

UNIT TO BE DELIBERATELY USED FOR

DECOMPRESSION DIVING.

HOWEVER, IF YOU PLAN TO PERFORM

DECOMPRESSION DIVES, WE RECOMMEND THAT

YOU HAVE ADEQUATE TRAINING, BACK UP

TABLES, AND AT LEAST TWO IDENTICAL

COCHRAN COMPUTERS.

DECOMPRESSION MODE

WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME

REQUIRED AT THE DISPLAYED CEILING DEPTH AND THE TOTAL TIME REQUIRED TO

COMPLETE ALL DECO STOPS.

AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR

NOT TO ALTERNATE.

DECOMPRESSION MODE

THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO

MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS.

THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10

FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

DECOMPRESSION MODE

IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES & DEC.

DEC

DEPTHMAXBOTTOM

CEILREMAIN TIME

DEPTH

Deco Stop Time(Alternates between Total Deco Time and time at current Stop)

N D CASC

TNE

B O T TO M

T E M PR E M A IN T IM E

D E P T HM A XD E P T H

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

No-Decompression Time

Decompression Time

Note NDC Legend

Note DEC Legend

THE TEMPerature LEGEND AND VALUES ARE REPLACED BY CEILing LEGEND AND VALUES.

Deco Ceiling

Water TemperatureNote TEMP Legend

Note CEIL Legend

Don’t go above this depth for optimum Decompression

IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES.

DEC

DEPTHMAXBOTTOM

CEILREMAIN TIME

DEPTH

Deco Ceiling

NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC

Deco Stop Time(Alternates

between Total Deco Time and time at current

Stop)

******************************

PLEASE NOTE THAT DEC TIME AND CEIL DEPTH ARE DISPLAYED ONLY WHEN THE

DIVER REQUIRES A DECOMPRESSION STOP.

IF THE DIVER DOES NOT REQUIRE A DECOMPRESSION STOP, ONLY NDC TIME

AND TEMP WILL BE DISPLAYED.

IF THE DEC LEGEND AND VALUES AREREPLACED WITH THE NDC LEGEND AND

VALUES, THEN YOU HAVE FULFILLED YOUR DECOMPRESSION OBLIGATIONS.

******************************

THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.

THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE

POST DIVE INTERVAL HAS PASSED.

DISPLAYED DATA

Air Temperature

Maximum Depth(of the last Dive)

Surface Time(Amount of time since last Dive)

Bottom Time(of the last Dive)

Dive of “Day”(Repetitive Dive

Number)

Time to Fly(Hours before safely flying)

(Post Dive Interval and Surface Interval)

SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE

INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE

PREVIOUS DIVE.

PROGRAMMING IS DISABLED.

NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY

WITH MANY USER PREFERENCES.

THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS

AND INDIVIDUAL STYLE OF DIVING.

MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER

FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

TOUCH CONTACT PROGRAMMING MODE

CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR

COCHRAN EMC-20H.

IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER.

THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SIX

PROGRAMMING MENUS.

WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1

AND 2 WITH A COIN.

THE FIRST MENU TO APPEAR IS PdP, PREDIVE PREDICTION.

ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU .

(Depth Alarm set to 124 feet)

THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU.

Conservatism set to 15%

THE FIFTH TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU.

On Time set to 10 seconds

THE SIXTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

T E M P

S U R F

ASC

TNE

EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR

PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW ADDITIONAL DATA

TO APPEAR ON THE SCREEN.

FOR EXAMPLE…

THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH

INCREASES THE PREDICT DEPTH BY 10 FEET.

AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

N D C

R E M A IN T IM E

.

D E P T H

Predict DepthCalculated PO2(Based on FO2 of 21%)

Predict NDC Time(Time you can Stay at predictDepth Without

Decompression)

PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND

CHANGE WITH SURFACE INTERVAL TIME.

PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME

PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED.

BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

THE INFORMATION SCREEN GIVES DATA REGARDING THE COMPUTER

CONFIGURATION AND THE BATTERY VOLTAGE.

.

Mode Blend Indicator(FO = Air only)

Battery Voltage(3.0 Volts)

THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.

THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

The Digit beingProgrammed will

Flash Until it is set and youMove on to the

next Digit.

WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.

The Digit beingProgrammed will

Flash

THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT

AVAILABLE FOR CHANGE.

A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.

TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR

WET FINGER.

WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE

DESIRED VALUE IS REACHED.

WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO

THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN

THE COMPUTER.

IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE

SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO

ANY OR ALL DIVES.

SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED,

SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER

CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A

PERCENT OF ADDITIONAL CONSERVATISM.

Conservatism set to 15%

A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 &

3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF

CONSERVATISM.

A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE TACLITE “ON TIME” OR DWELL.

THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES

OF OVER-DEPLETING THE BATTERY.

ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK.

YOU SIMPLY PROGRAM THE TACLITE TO REMAIN ON FOR WHATEVER TIME YOU

CHOOSE.

THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM

1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON.

A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

On Time set to 10 seconds

THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.

THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST

RECENT 512 DIVES.

Logbook Dive Number

TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN,

WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE.

Day Month Year

Minutes00 to 59

Hour00 to 24

THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE

LOGBOOK MODE.

OVERALL DIVE NUMBER

MINIMUM WATER TEMPERATURE

SURFACE INTERVAL BEFORE DIVE

BOTTOM DIVE

MINIMUM NDC TIME

FASTEST RATE OF ASCENT

MAXIMUM CEILING (DECO DIVE)

MAXIMUM DEC TIME (DECO DIVE)

ENDING BATTERY VOLTAGE

DATE AND TIME OF DIVE

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M

T E M P

S U R F

N D C

R E M A IN T IM E

Water Temperature(Minimum recorded

during the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

NDC Time Remain(Minimum NDC time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A NORMAL DIVE

ALTERNATE LOGBOOK SCREEN

FOR A NORMAL DIVE

.

Battery Voltage(2.9 Volts)

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M S U R F

R E M A IN T IM E

D E C

C E IL

Deepest Deco Ceiling(Recorded during

the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

DEC Time Remain(Maximum Deco time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A DECO DIVE

ALTERNATE LOGBOOK SCREEN

T E M P

Battery Voltage(2.9 Volts)

Water Temperature(Minimum recorded

during the dive)

FOR A DECO DIVE

YOU HAVE JUST COMPLETED A PRESENTATION ON SOME OF THE MANY

FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER.

YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND

OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT

A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE.

VISIT www.divecochran.com

CLICK ON “PRODUCT MANUALS.”

VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE

www.divecochran.com

AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR ENRICHED

AIR NITROX APPLICATIONS.

COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING”

YOUR COMPUTER.

HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!

Click on the door to go back to the main selection screen orclick on the stop sign to exit.

THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC

FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE

SINGLE GAS COCHRAN EMC-20H.

PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.

ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE

DIVING.

SIDE CONTACTS:

Locate the three side contacts.

TURN ME ON

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE

BLADE, AND YOUR FINGER.

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT

WATER, FRESH WATER, AND YOUR WET FINGER.

Contact #3

Contact #2

Contact #1

SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET

FINGER ACTIVATES THE UNIT.

A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

Contact #2

Contact #1

THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”

ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-

TEST WHEN SUCCESSFULLY COMPLETED.

DI

VE

B AT T

N D CD E C

ASC

TNE

D E P T HM A XB O T TO M

C E ILT E M PW A R N I N GR E M A IN T IM E F LY

S U R F D E P T HM E T R IC

. .

AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS

TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS.

ALTITUDE APPEARS IN ASCENT BAR GRAPH

T E M P

S U R F

ASC

TNE

Air Temperature

Surface TimeBarometric

Altitude (2500 feetper bar

No bars = 0 - 25002 bars = 5000 - 7500)

UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE.

T E M P

S U R F

ASC

TNE

THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.

MAINSCREEN

ALTERNATESCREEN

IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY

ADDITIONAL INFORMATION.

Maximum Depth(of the last dive)

Air Temperature

Bottom Time(of the last dive)

Surface Time(Amount of timesince last dive)

Time to Fly(Hours beforesafely flying)

Dive of “Day”(Repetitive Dive

Number)

ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN

Battery Voltage(2.9 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Nitrox O2%(Of Blend #1 Set Point)

IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND

AUTOMATICALLY GOES TO SLEEP.

LET’S GO DIVING

AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES

OTHER PROGRAMMING AND DISPLAY MODES.

IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY

POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF.

CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

DURING A DIVE, THE FOLLOWING

DATA IS AVAILABLE IN A LARGE, EASY

TO READ DISPLAY.

Water Temperature

Current DepthCurrent PO2Bottom Time(so far this dive)

NDC Time Remain(Time you can stay

At current depth without

Decompression)

Ascent Rate(4 bars = 40-49 fpm)

MAIN SCREEN VISIBLE DURING A DIVE

Note NDC Legend

ALTERNATE SCREEN THAT MAY BEVIEWED DURING A DIVE

Nitrox O2%(Of Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES.

THE REMAIN TIME NUMBERS FLASH

THE WARNING LEGEND APPEARS AND FLASHES

AN AUDIBLE ALARM WILL BE ISSUED

SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER

AUTOMATICALLY ENTERS THE DECOMPRESSION MODE.

STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL

CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

COCHRAN DOES NOT INTEND FOR THIS

UNIT TO BE DELIBERATELY USED FOR

DECOMPRESSION DIVING.

HOWEVER, IF YOU PLAN TO PERFORM

DECOMPRESSION DIVES, WE RECOMMEND THAT

YOU HAVE ADEQUATE TRAINING, BACK UP

TABLES, AND AT LEAST TWO IDENTICAL

COCHRAN COMPUTERS.

DECOMPRESSION MODE

WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND

THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS.

AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR

NOT TO ALTERNATE.

DECOMPRESSION MODE

THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO

MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS.

THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10

FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

DECOMPRESSION MODE

IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.

Deco Stop Time(Alternates between Total Deco Time and time at current Stop)

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

No-Decompression Time

Decompression Time

Note NDC Legend

Note DEC Legend

THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.

Deco Ceiling

Water TemperatureNote TEMP Legend

Note CEIL Legend

Don’t go above this depth for optimum Decompression

Deco Ceiling

IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES.

NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC

Deco Stop Time(Alternates

between Total Deco Time and time at current

Stop)

ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION

Nitrox O2%(Of current Blend

Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

Water Temperature

THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.

THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE

POST-DIVE INTERVAL HAS PASSED.

DISPLAYED DATA

Air Temperature

Maximum Depth(of the last Dive)

Surface Time(Amount of time since last Dive)

Bottom Time(of the last Dive)

Dive of “Day”(Repetitive Dive

Number)

Time to Fly(Hours before safely flying)

(Post Dive Interval and Surface Interval)

SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE

INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE

PREVIOUS DIVE.

PROGRAMMING IS DISABLED.

NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY

WITH MANY USER PREFERENCES.

THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS

AND INDIVIDUAL STYLE OF DIVING.

MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER

FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

TOUCH CONTACT PROGRAMMING MODE

CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR

COCHRAN EMC-20H.

IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER.

THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE

SEVEN PROGRAMMING MENUS.

WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1

AND 2 WITH A COIN.

THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.

(Depth Alarm set to 124 feet)

THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU.

Conservatism set to 15%

THE FIFTH TOUCH BRINGS UP THE EAn 1 MENU FOR SETTING BLEND#1 O2%.

Blend #1 set to 21.0% O2

THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU.

On Time set to 10 seconds

THE SEVENTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

T E M P

S U R F

ASC

TNE

EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR

PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL

DATA TO APPEAR ON THE SCREEN.

FOR EXAMPLE…

AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

N D C

R E M A IN T IM E

.

D E P T H

Predict DepthCalculated PO2(Based on Blend #1 Set Point)

Predict NDC Time(Time you can Stay at predictDepth Without

Decompression)

THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH

INCREASES THE PREDICT DEPTH BY 10 FEET.

PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME

PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED.

BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND

CHANGE WITH SURFACE INTERVAL TIME.

Mode Blend Indicator(F1 = 1 FO2)

Battery Voltage(3.0 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION

SCREEN.

THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT

CONFIGURATION AND BATTERY VOLTAGE.

THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.

THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

The Digit beingProgrammed will

Flash Until it is set and youMove on to the

next Digit.

WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.

The Digit beingProgrammed will

Flash

THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT

AVAILABLE FOR CHANGE.

A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.

TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR

WET FINGER.

WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE

DESIRED VALUE IS REACHED.

WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO

THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN

THE COMPUTER.

IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE

PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE

SETTINGS ARE AS INTENDED.

IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO

ANY OR ALL DIVES.

SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED,

SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER

CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

Conservatism set to 15%

THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A

PERCENT OF ADDITIONAL CONSERVATISM.

A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 &

3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF

CONSERVATISM.

A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE O2% IN BLEND #1.

Blend #1 set to 32.0%

FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN

BLEND #1 FROM 21.0 TO 50.0%.

THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE TACLITE “ON TIME” OR DWELL.

THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES

OF OVER-DEPLETING THE BATTERY.

ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK

OR LEAK.

YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

On Time set to 10 seconds

THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM

1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON.

A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.

THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST

RECENT 512 DIVES.

Logbook Dive Number

TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN,

WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE.

Day Month Year

Minutes00 to 59

Hour00 to 24

THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE

LOGBOOK MODE.

OVERALL DIVE NUMBER

MINIMUM WATER TEMPERATURE

SURFACE INTERVAL BEFORE DIVE

BOTTOM DIVE

MINIMUM NDC TIME

FASTEST RATE OF ASCENT

MAXIMUM CEILING (DECO DIVE)

MAXIMUM DEC TIME (DECO DIVE)

ENDING BATTERY VOLTAGE

DATE AND TIME OF DIVE

CNS and OTU OXYGEN TOXICITY VALUES

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M

T E M P

S U R F

N D C

R E M A IN T IM E

Water Temperature(Minimum recorded

during the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

NDC Time Remain(Minimum NDC time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A NORMAL DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Nitrox O2%(Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

FOR A NORMAL DIVE

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M S U R F

R E M A IN T IM E

D E C

C E IL

Deepest Deco Ceiling(Recorded during

the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

DEC Time Remain(Maximum Deco time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A DECO DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Water Temperature(Minimum recorded

during the dive)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Nitrox O2%(Blend #1 Set Point)

FOR A DECO DIVE

YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY

FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER.

YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND

OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT

A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE.

VISIT www.divecochran.com

FIRST CLICK ON “PRODUCT MANUALS.”

COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING”

YOUR COMPUTER.

VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE

www.divecochran.com

AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE

ENRICHED AIR NITROX APPLICATIONS.

HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!

Click on the door to go back to the main selection screen orclick on the stop sign to exit.

THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC

FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE

TWO GAS COCHRAN EMC-20H.

PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.

ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

SIDE CONTACTS:

Locate the three side contacts.

TURN ME ON

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE

BLADE, AND YOUR FINGER.

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT

WATER, FRESH WATER, AND YOUR WET FINGER.

Contact #3

Contact #2

Contact #1

SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET

FINGER ACTIVATES THE UNIT.

A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

Contact #2

Contact #1

THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”

DI

VE

B AT T

N D C

D E C

ASC

TNE

D E P T HM A XB O T TO M

C E ILT E M PW A R N I N GR E M A IN T IM E F LY

S U R F D E P T HM E T R IC

. .

ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-

TEST WHEN SUCCESSFULLY COMPLETED.

AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT

DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS.

ALTITUDE APPEARS IN ASCENT BAR GRAPH

T E M P

S U R F

ASC

TNE

Air Temperature

Surface TimeBarometric

Altitude (2500 feetper bar

No bars = 0 - 25002 bars = 5000 - 7500)

UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE.

T E M P

S U R F

ASC

TNE

THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE PLACE OF THE UNIT.

MAINSCREEN

ALTERNATESCREEN

IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY

ADDITIONAL INFORMATION.

Maximum Depth(of the last dive)

Air Temperature

Bottom Time(of the last dive)

Surface Time(Amount of timesince last dive)

Time to Fly(Hours beforesafely flying)

Dive of “Day”(Repetitive Dive

Number)

ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN

Battery Voltage(2.9 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Nitrox O2%(Of Blend #1 Set Point)

IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND

AUTOMATICALLY GOES TO SLEEP.

LET’S GO DIVING

AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES

OTHER PROGRAMMING AND DISPLAY MODES.

IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY

POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF.

CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

DURING A DIVE, THE FOLLOWING

DATA IS AVAILABLE IN A LARGE, EASY

TO READ DISPLAY.

Water Temperature

Current DepthCurrent PO2Bottom Time(so far this dive)

NDC Time Remain(Time you can stay

At current depth without

Decompression)

Ascent Rate(4 bars = 40-49 fpm)

MAIN SCREEN VISIBLE DURING A DIVE

Note NDC Legend

ALTERNATE SCREEN THAT MAY BEVIEWED DURING A DIVE

Nitrox O2%(Of Current Blend Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES.

THE REMAIN TIME NUMBERS FLASH

THE WARNING LEGEND APPEARS AND FLASHES

AN AUDIBLE ALARM WILL BE ISSUED

SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE

DECOMPRESSION MODE.

STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL

CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

COCHRAN DOES NOT INTEND FOR THIS

UNIT TO BE DELIBERATELY USED FOR

DECOMPRESSION DIVING.

HOWEVER, IF YOU PLAN TO PERFORM

DECOMPRESSION DIVES, WE RECOMMEND THAT

YOU HAVE ADEQUATE TRAINING, BACK UP

TABLES, AND AT LEAST TWO IDENTICAL

COCHRAN COMPUTERS.

DECOMPRESSION MODE

WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND

THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS.

AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR

NOT TO ALTERNATE.

DECOMPRESSION MODE

THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO

MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS.

THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10

FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

DECOMPRESSION MODE

IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.

Deco Stop Time(Alternates between Total Deco Time and time at current Stop)

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

No-Decompression Time

Decompression Time

Note NDC Legend

Note DEC Legend

THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.

Deco Ceiling

Water Temperature

Note TEMP Legend

Note CEIL Legend

Don’t go above this depth for optimum Decompression

IN THIS EXAMPLE, THE DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES.

Deco Ceiling

NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC

Deco Stop Time(Alternates

between Total Deco Time and time at current

Stop)

ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION

Nitrox O2%(Of current Blend

Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

Water Temperature

THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.

THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE

POST DIVE INTERVAL HAS PASSED.

DISPLAYED DATA

Air Temperature

Maximum Depth(of the last Dive)

Surface Time(Amount of time since last Dive)

Bottom Time(of the last Dive)

Dive of “Day”(Repetitive Dive

Number)

Time to Fly(Hours before safely flying)

(Post Dive Interval and Surface Interval)

SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE

INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE

PREVIOUS DIVE.

PROGRAMMING IS DISABLED.

NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY

WITH MANY USER PREFERENCES.

THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS

AND INDIVIDUAL STYLE OF DIVING.

MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER

FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

TOUCH CONTACT PROGRAMMING MODE

CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR

COCHRAN EMC-20H.

IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER.

THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN

PROGRAMMING MENUS.

WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1

AND 2 WITH A COIN.

THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.

(Depth Alarm set to 124 feet)

Conservatism set to 15%

THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU

USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

THE FIFTH TOUCH BRINGS UP THE EAn 1, BLEND#1 O2% MENU.

Blend #1 set to 21.0% O2

THE NEXT TOUCH BRINGS UP THE EAn 2, DECO BLEND O2% MENU.

Deco Blend set to 21.0% O2

THE SEVENTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU.

Deco Blend Time Benchmark set to

600 minutesSO WHAT IS A BENCHMARK ?

THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU.

Deco Blend DepthBenchmark set to

0 feetSO WHAT IS A BENCHMARK ?

THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU.

On Time set to 10 seconds

THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.

ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

T E M P

S U R F

ASC

TNE

TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR

PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL

DATA TO APPEAR ON THE SCREEN.

FOR EXAMPLE…

N D C

R E M A IN T IM E

.

D E P T H

Predict DepthCalculated PO2(Based on Blend #1 Set Point)

Predict NDC Time(Time you can stay

At predict depth without

Decompression)

AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH

INCREASES THE PREDICT DEPTH BY 10 FEET.

PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME

PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED.

BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND

CHANGE WITH SURFACE INTERVAL TIME.

THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT

CONFIGURATION AND BATTERY VOLTAGE.

Mode Blend Indicator(F2 = 2 FO2)

BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION

SCREEN.

Battery Voltage(3.0 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.

THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

The Digit beingProgrammed will

Flash Until it is set and youMove on to the

next Digit.

WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.

The Digit beingProgrammed will

Flash

THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT

AVAILABLE FOR CHANGE.

A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.

TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR

WET FINGER.

WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE

DESIRED VALUE IS REACHED.

WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO

THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN

THE COMPUTER.

IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE

PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE

LIMITS ARE AS INTENDED.

IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO

YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED,

SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER

CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A

PERCENT OF CONSERVATISM.

Conservatism set to 15%

A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND

2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF

ADDITIONAL CONSERVATISM.

A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1 .

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE OXYGEN PERCENTAGE FOR BLEND #1.

Blend #1 set to 32.0%

FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE O2% IN

BLEND #1 FROM 21.0 TO 50.0%

THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 O2% SETTING AND BRING UP THE EAn 2 MENU WHERE YOU SET THE O2% FOR THE

DECO BLEND.

SET YOUR DECO BLEND O2 PERCENTAGE ANYWHERE FROM 21.0 TO 99.9%

Deco Blend set to 80.0%

ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET

THE DECO BLEND TIME BENCHMARK.

WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES,

YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES

Deco Blend Time Benchmark set to 70 minutes

SO WHAT IS A BENCHMARK ?

THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND

DEPTH BENCHMARK.

FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND

DEPTH BENCHMARK FROM 0 TO 99 FEET.

Deco Blend Depth Benchmark

set to 20 feet

SO WHAT IS A BENCHMARK ?

THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE TACLITE “ON TIME” OR DWELL.

THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES

OF OVER-DEPLETING THE BATTERY.

ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK

OR LEAK.

YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

On Time set to 10 seconds

THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM

1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON.

A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.

THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST

RECENT 512 DIVES.

Logbook Dive Number

TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN,

WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE.

Day Month Year

Minutes00 to 59

Hour00 to 24

THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE

LOGBOOK MODE.

OVERALL DIVE NUMBER

MINIMUM WATER TEMPERATURE

SURFACE INTERVAL BEFORE DIVE

BOTTOM DIVE

MINIMUM NDC TIME

FASTEST RATE OF ASCENT

MAXIMUM CEILING (DECO DIVE)

MAXIMUM DEC TIME (DECO DIVE)

ENDING BATTERY VOLTAGE

DATE AND TIME OF DIVE

CNS and OTU OXYGEN TOXICITY VALUES

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M

T E M P

S U R F

N D C

R E M A IN T IM E

Water Temperature(Minimum recorded

during the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

NDC Time Remain(Minimum NDC time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A NORMAL DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Nitrox O2%(Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

FOR A NORMAL DIVE

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M S U R F

R E M A IN T IM E

D E C

C E IL

Deepest Deco Ceiling(Recorded during

the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

DEC Time Remain(Maximum Deco time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A DECO DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Water Temperature(Minimum recorded

during the dive)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Nitrox O2%(Blend #1 Set Point)

FOR A DECO DIVE

YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY

FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER.

YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND

OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT

A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE.

VISIT www.divecochran.com

FIRST CLICK ON “PRODUCT MANUALS.”

HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!

Click on the door to go back to the main selection screen orclick on the stop sign to exit.

WHAT ARE BENCHMARKS?

Click here to return to Touch Contact Programming Return

BENCHMARKS ARE CONDITIONS THAT MUST BE SATISFIED BEFORE THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL

OCCUR.

THE “Dec b” BENCHMARK IS THE BOTTOM TIME OF THE DIVE AFTER WHICH THE GAS SWITCHING WILL BE ENABLED. ONCE

THE PROGRAMMED TIME HAS BEEN SATISFIED, THE GAS SWITCH WILL BE CONTROLLED BY DEPTH

THE “Dec d” BENCHMARK IS THE DEPTH OF THE GAS SWITCH. ONCE THE DIVER ASCENDS ABOVE THE PROGRAMMED DEPTH, THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL HAPPEN. IF BENCHMARK “Dec b” IS NOT SATISFIED THERE WILL NOT BE A

GAS SWITCH.

THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC

FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE

SINGLE PO2 COCHRAN EMC-20H.

PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.

ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE

DIVING.

SIDE CONTACTS:

Locate the three side contacts.

TURN ME ON

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE

BLADE, AND YOUR FINGER.

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT

WATER, FRESH WATER, AND YOUR WET FINGER.

Contact #3

Contact #2

Contact #1

SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET

FINGER ACTIVATES THE UNIT.

A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

Contact #2

Contact #1

THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”

ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-

TEST WHEN SUCCESSFULLY COMPLETED.

DI

VE

B AT T

N D CD E C

ASC

TNE

D E P T HM A XB O T TO M

C E ILT E M PW A R N I N GR E M A IN T IM E F LY

S U R F D E P T HM E T R IC

. .

AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS

TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS.

ALTITUDE APPEARS IN ASCENT BAR GRAPH

T E M P

S U R F

ASC

TNE

Air Temperature

Surface TimeBarometric

Altitude (2500 feetper bar

No bars = 0 - 25002 bars = 5000 - 7500)

UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE.

T E M P

S U R F

ASC

TNE

THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.

MAINSCREEN

ALTERNATESCREEN

IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY

ADDITIONAL INFORMATION.

Maximum Depth(of the last dive)

Air Temperature

Bottom Time(of the last dive)

Surface Time(Amount of timesince last dive)

Time to Fly(Hours beforesafely flying)

Dive of “Day”(Repetitive Dive

Number)

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

PO2 in ATA(Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

FOR A NORMAL DIVE

IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND

AUTOMATICALLY GOES TO SLEEP.

LET’S GO DIVING

AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES

OTHER PROGRAMMING AND DISPLAY MODES.

IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY

POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF.

CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

DURING A DIVE, THE FOLLOWING

DATA IS AVAILABLE IN A LARGE, EASY

TO READ DISPLAY.

Water Temperature

Current DepthCurrent FO2Bottom Time(so far this dive)

NDC Time Remain(Time you can stay

At current depth without

Decompression)

Ascent Rate(1 bar = 10-19 fpm)

MAIN SCREEN VISIBLE DURING A DIVE

Note NDC Legend

ALTERNATE SCREEN THAT MAY BEVIEWED DURING A DIVE

PO2 in ATA(Of Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES.

THE REMAIN TIME NUMBERS FLASH

THE WARNING LEGEND APPEARS AND FLASHES

AN AUDIBLE ALARM WILL BE ISSUED

SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER

AUTOMATICALLY ENTERS THE DECOMPRESSION MODE.

STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL

CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

COCHRAN DOES NOT INTEND FOR THIS

UNIT TO BE DELIBERATELY USED FOR

DECOMPRESSION DIVING.

HOWEVER, IF YOU PLAN TO PERFORM

DECOMPRESSION DIVES, WE RECOMMEND THAT

YOU HAVE ADEQUATE TRAINING, BACK UP

TABLES, AND AT LEAST TWO IDENTICAL

COCHRAN COMPUTERS.

DECOMPRESSION MODE

WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND

THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS.

AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR

NOT TO ALTERNATE.

DECOMPRESSION MODE

THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO

MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS.

THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10

FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

DECOMPRESSION MODE

IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.

Deco Stop Time(Alternates between Total Deco Time and time at current Stop)

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

No-Decompression Time

Decompression Time

Note NDC Legend

Note DEC Legend

THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.

Deco Ceiling

Water TemperatureNote TEMP Legend

Note CEIL Legend

Don’t go above this depth for optimum Decompression

Deco Ceiling

IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES.

NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC

Deco Stop Time(Alternates

between Total Deco Time and time at current

Stop)

ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION

PO2 in ATA(Of current Blend

Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

Water Temperature

THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.

THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE

POST-DIVE INTERVAL HAS PASSED.

DISPLAYED DATA

Air Temperature

Maximum Depth(of the last Dive)

Surface Time(Amount of time since last Dive)

Bottom Time(of the last Dive)

Dive of “Day”(Repetitive Dive

Number)

Time to Fly(Hours before safely flying)

(Post Dive Interval and Surface Interval)

SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE

INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE

PREVIOUS DIVE.

PROGRAMMING IS DISABLED.

NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY

WITH MANY USER PREFERENCES.

THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS

AND INDIVIDUAL STYLE OF DIVING.

MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER

FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

TOUCH CONTACT PROGRAMMING MODE

CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR

COCHRAN EMC-20H.

IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER.

THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE

EIGHT PROGRAMMING MENUS.

WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1

AND 2 WITH A COIN.

THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2

OPERATING MODE.

FO2SCREEN

PO2SCREEN

THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.

ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.

(Depth Alarm set to 124 feet)

THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU.

Conservatism set to 15%

THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2.

Blend #1 set to 0.70 ATA

THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU.

On Time set to 10 seconds

THE EIGHTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

T E M P

S U R F

ASC

TNE

EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR

PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL

DATA TO APPEAR ON THE SCREEN.

FOR EXAMPLE…

AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

Predict DepthPO2 Set Point

Predict NDC Time(Time you can Stay at predictDepth Without

Decompression)

THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH

INCREASES THE PREDICT DEPTH BY 10 FEET.

PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME

PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED.

BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND

CHANGE WITH SURFACE INTERVAL TIME.

Mode Blend Indicator(P1 = 1 PO2)

Battery Voltage(3.0 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION

SCREEN.

THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT

CONFIGURATION AND BATTERY VOLTAGE.

THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.

THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

The Digit beingProgrammed will

Flash Until it is set and youMove on to the

next Digit.

WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.

The Digit beingProgrammed will

Flash

THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT

AVAILABLE FOR CHANGE.

A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.

TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR

WET FINGER.

WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE

DESIRED VALUE IS REACHED.

WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO

THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN

THE COMPUTER.

IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE

PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE

SETTINGS ARE AS INTENDED.

IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO

ANY OR ALL DIVES.

SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED,

SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER

CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

Conservatism set to 15%

THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A

PERCENT OF ADDITIONAL CONSERVATISM.

A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 &

3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF

CONSERVATISM.

A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE PO2 IN BLEND #1.

Blend #1 set to 0.70 ATA

FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE PO2 IN

BLEND #1 FROM 0.50 TO 1.50 ATA.

THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE TACLITE “ON TIME” OR DWELL.

THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES

OF OVER-DEPLETING THE BATTERY.

ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK

OR LEAK.

YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

On Time set to 10 seconds

THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM

1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON.

A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.

THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST

RECENT 512 DIVES.

Logbook Dive Number

TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN,

WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE.

Day Month Year

Minutes00 to 59

Hour00 to 24

THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE

LOGBOOK MODE.

OVERALL DIVE NUMBER

MINIMUM WATER TEMPERATURE

SURFACE INTERVAL BEFORE DIVE

BOTTOM DIVE

MINIMUM NDC TIME

FASTEST RATE OF ASCENT

MAXIMUM CEILING (DECO DIVE)

MAXIMUM DEC TIME (DECO DIVE)

ENDING BATTERY VOLTAGE

DATE AND TIME OF DIVE

CNS and OTU OXYGEN TOXICITY VALUES

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M

T E M P

S U R F

N D C

R E M A IN T IM E

Water Temperature(Minimum recorded

during the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

NDC Time Remain(Minimum NDC time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A NORMAL DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

PO2 in ATA(Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

FOR A NORMAL DIVE

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M S U R F

R E M A IN T IM E

D E C

C E IL

Deepest Deco Ceiling(Recorded during

the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

DEC Time Remain(Maximum Deco time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A DECO DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Water Temperature(Minimum recorded

during the dive)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

PO2 in ATA(Blend #1 Set Point)

FOR A DECO DIVE

YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY

FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER.

YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND

OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT

A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE.

VISIT www.divecochran.com

FIRST CLICK ON “PRODUCT MANUALS.”

COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING”

YOUR COMPUTER.

VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE

www.divecochran.com

AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE

ENRICHED AIR NITROX APPLICATIONS.

HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!

Click on the door to go back to the main selection screen orclick on the stop sign to exit.

THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC

FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE

TWO PO2 COCHRAN EMC-20H.

PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL.

ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

SIDE CONTACTS:

Locate the three side contacts.

TURN ME ON

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE

BLADE, AND YOUR FINGER.

Contact #3

Contact #2

Contact #1

SIDE CONTACTS:

THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT

WATER, FRESH WATER, AND YOUR WET FINGER.

Contact #3

Contact #2

Contact #1

SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET

FINGER ACTIVATES THE UNIT.

A SHORT SERIES OF BEEPS SIGNALS ACTIVATION.

Contact #2

Contact #1

THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.”

DI

VE

B AT T

N D C

D E C

ASC

TNE

D E P T HM A XB O T TO M

C E ILT E M PW A R N I N GR E M A IN T IM E F LY

S U R F D E P T HM E T R IC

. .

ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF-

TEST WHEN SUCCESSFULLY COMPLETED.

AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT

DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS.

ALTITUDE APPEARS IN ASCENT BAR GRAPH

T E M P

S U R F

ASC

TNE

Air Temperature

Surface TimeBarometric

Altitude (2500 feetper bar

No bars = 0 - 25002 bars = 5000 - 7500)

UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE.

T E M P

S U R F

ASC

TNE

THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT.

MAINSCREEN

ALTERNATESCREEN

IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY

ADDITIONAL INFORMATION.

Maximum Depth(of the last dive)

Air Temperature

Bottom Time(of the last dive)

Surface Time(Amount of timesince last dive)

Time to Fly(Hours beforesafely flying)

Dive of “Day”(Repetitive Dive

Number)

ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN

Battery Voltage(2.9 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

PO2 in ATA(Of Blend #1 Set Point)

IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND

AUTOMATICALLY GOES TO SLEEP.

LET’S GO DIVING

AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES

OTHER PROGRAMMING AND DISPLAY MODES.

IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY

POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF.

CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

DURING A DIVE, THE FOLLOWING

DATA IS AVAILABLE IN A LARGE, EASY

TO READ DISPLAY.

Water Temperature

Current DepthCurrent FO2Bottom Time(so far this dive)

NDC Time Remain(Time you can stay

At current depth without

Decompression)

Ascent Rate(1 bar = 10-19 fpm)

MAIN SCREEN VISIBLE DURING A DIVE

Note NDC Legend

ALTERNATE SCREEN THAT MAY BEVIEWED DURING A DIVE

PO2 in ATA(Of Current Blend Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

A “TWO MINUTE WARNING” IS ISSUED WHEN NO–DECOMPRESSION TIME REACHES 2 MINUTES.

THE REMAIN TIME NUMBERS FLASH

THE WARNING LEGEND APPEARS AND FLASHES

AN AUDIBLE ALARM WILL BE ISSUED

SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER

AUTOMATICALLY ENTERS THE DECOMPRESSION MODE.

STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL

CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

COCHRAN DOES NOT INTEND FOR THIS

UNIT TO BE DELIBERATELY USED FOR

DECOMPRESSION DIVING.

HOWEVER, IF YOU PLAN TO PERFORM

DECOMPRESSION DIVES, WE RECOMMEND THAT

YOU HAVE ADEQUATE TRAINING, BACK UP

TABLES, AND AT LEAST TWO IDENTICAL

COCHRAN COMPUTERS.

DECOMPRESSION MODE

WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND

THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS.

AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR

NOT TO ALTERNATE.

DECOMPRESSION MODE

THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO

MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS.

THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10

FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES.

DECOMPRESSION MODE

IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC.

Deco Stop Time(Alternates between Total Deco Time and time at current Stop)

NDC Time Remain(Time you can stay atcurrent depth without

Decompression)

No-Decompression Time

Decompression Time

Note NDC Legend

Note DEC Legend

THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES.

Deco Ceiling

Water TemperatureNote TEMP Legend

Note CEIL Legend

Don’t go above this depth for optimum Decompression

Deco Ceiling

IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES.

NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC

Deco Stop Time(Alternates

between Total Deco Time and time at current

Stop)

ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION

PO2 in ATA(Of current Blend

Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

Max Depth(of current dive)

Water Temperature

THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL.

THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE

POST DIVE INTERVAL HAS PASSED.

DISPLAYED DATA

Air Temperature

Maximum Depth(of the last Dive)

Surface Time(Amount of time since last Dive)

Bottom Time(of the last Dive)

Dive of “Day”(Repetitive Dive

Number)

Time to Fly(Hours before safely flying)

(Post Dive Interval and Surface Interval)

SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE

INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE

PREVIOUS DIVE.

PROGRAMMING IS DISABLED.

NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY

WITH MANY USER PREFERENCES.

THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS

AND INDIVIDUAL STYLE OF DIVING.

MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER

FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

TOUCH CONTACT PROGRAMMING MODE

CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR

COCHRAN EMC-20H.

IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER.

THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN

PROGRAMMING MENUS.

WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1

AND 2 WITH A COIN.

THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2

OPERATING MODE.

FO2SCREEN

PO2SCREEN

TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.

THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU.

(Depth Alarm set to 124 feet)

Conservatism set to 15%

THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU

USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2.

Blend #1 set to 0.70 ATA

THE NEXT TOUCH BRINGS UP THE PO2 2, DECO BLEND PO2 MENU.

Deco Blend set to 1.30 ATA

THE EIGHTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU.

Deco Blend Time Benchmark set to

600 minutesSO WHAT IS A BENCHMARK ?

THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU.

Deco Blend DepthBenchmark set to

0 feetSO WHAT IS A BENCHMARK ?

THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU.

On Time set to 10 seconds

THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.

ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

T E M P

S U R F

ASC

TNE

TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR

PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL

DATA TO APPEAR ON THE SCREEN.

FOR EXAMPLE…

AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET.

Predict DepthPO2 Set Point

Predict NDC Time(Time you can Stay at predictDepth Without

Decompression)

THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH

INCREASES THE PREDICT DEPTH BY 10 FEET.

PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME

PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED.

BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND

CHANGE WITH SURFACE INTERVAL TIME.

THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT

CONFIGURATION AND BATTERY VOLTAGE.

Mode Blend Indicator(P2 = 2 PO2)

BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION

SCREEN.

Battery Voltage(3.0 Volts)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU.

THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING.

The Digit beingProgrammed will

Flash Until it is set and youMove on to the

next Digit.

WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3.

The Digit beingProgrammed will

Flash

THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT

AVAILABLE FOR CHANGE.

A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9.

TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR

WET FINGER.

WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE

DESIRED VALUE IS REACHED.

WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO

THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN

THE COMPUTER.

IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE

PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE

LIMITS ARE AS INTENDED.

IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO

YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES.

SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED,

SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER

CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A

PERCENT OF CONSERVATISM.

Conservatism set to 15%

A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND

2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF

ADDITIONAL CONSERVATISM.

A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 .

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE PO2 VALUE FOR BLEND #1.

Blend #1 set to 0.70 ATA

FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE PO2 IN

BLEND #1 FROM 0.50 TO 1.50 ATA.

THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 PO2 SETTING AND BRING UP THE PO2 2 MENU WHERE YOU SET THE PO2 FOR THE

DECO BLEND.

SET YOUR DECO BLEND PO2 IN ATA ANYWHERE FROM 0.50 TO 1.50.

Deco Blend set to 1.30 ATA

ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET

THE DECO BLEND TIME BENCHMARK.

WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES,

YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES

Deco Blend Time Benchmark set to 70 minutes

SO WHAT IS A BENCHMARK ?

THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND

DEPTH BENCHMARK.

FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND

DEPTH BENCHMARK FROM 0 TO 99 FEET.

Deco Blend Depth Benchmark

set to 20 feet

SO WHAT IS A BENCHMARK ?

THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl.

A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR

SETTING THE TACLITE “ON TIME” OR DWELL.

THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW-LIGHT CONDITIONS WITHOUT THE WORRIES

OF OVER-DEPLETING THE BATTERY.

ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK

OR LEAK.

YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

On Time set to 10 seconds

THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM

1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON.

A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE.

THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST

RECENT 512 DIVES.

Logbook Dive Number

TAPPING THE FACE OF YOUR COCHRAN EMC-20H WILL ACTIVATE AN ALTERNATE SCREEN,

WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE.

Day Month Year

Minutes00 to 59

Hour00 to 24

THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE

LOGBOOK MODE.

OVERALL DIVE NUMBER

MINIMUM WATER TEMPERATURE

SURFACE INTERVAL BEFORE DIVE

BOTTOM DIVE

MINIMUM NDC TIME

FASTEST RATE OF ASCENT

MAXIMUM CEILING (DECO DIVE)

MAXIMUM DEC TIME (DECO DIVE)

ENDING BATTERY VOLTAGE

DATE AND TIME OF DIVE

CNS and OTU OXYGEN TOXICITY VALUES

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M

T E M P

S U R F

N D C

R E M A IN T IM E

Water Temperature(Minimum recorded

during the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

NDC Time Remain(Minimum NDC time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A NORMAL DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

PO2 in ATA(Blend #1 Set Point)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

FOR A NORMAL DIVE

PRIMARY LOGBOOK SCREEN

ASC

TNE

D E P T HM A XB O T TO M S U R F

R E M A IN T IM E

D E C

C E IL

Deepest Deco Ceiling(Recorded during

the dive)

Maximum Depth(of the dive)

Surface Time(Amount of timesince last dive)

Bottom Time(of the dive)

DEC Time Remain(Maximum Deco time

during the dive)

Ascent Rate(Maximum recordedon dive 40 - 49 fpm)

FOR A DECO DIVE

ALTERNATE LOGBOOK SCREEN

Battery Voltage(2.9 Volts)

Water Temperature(Minimum recorded

during the dive)

OTU OxygenToxicity in %

CNS OxygenToxicity in %

PO2 in ATA(Blend #1 Set Point)

FOR A DECO DIVE

YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY

FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER.

YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND

OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT

A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE.

VISIT www.divecochran.com

FIRST CLICK ON “PRODUCT MANUALS.”

HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE!

Click on the door to go back to the main selection screen orclick on the stop sign to exit.