2014 breaktanks english
Post on 08-Apr-2016
214 Views
Preview:
DESCRIPTION
TRANSCRIPT
w w w . b r e a k t a n k s . c o m
Safe handling of water
RegenwaterWoningbouw
Afvalwater
Afkoppelen & infiltratie
Regenwaterutiliteitsbouw
DEHOUST Tanks
Breaktanks
Grijswater
Breaktanks
Rainwater Rainwater
Woningbouw
Afkoppelen & infiltratie
Rainwaterutiliteitsbouw
DEHOUST Tanks
Grijswater
Afvalwater
Breaktanks
DEHOUST Tanks
Grey Water
Drinking water
Disconnecting & Infiltration
Waste Water
Breaktanks
www.breaktanks.com BreaktanksB2 © GEP Tel. BE +32 (0)56/299.701 NL +31 (0)183 610520
A break tank is a reservoir which is placed between the water gauge and one or more connection point. Break tanks are also known as disconnection tanks. Such break tanks are applied where a where an interruption of the water supply is necessary or mandatory.
The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.
The break tank acts as a safety buffer, which prevents the backflow of contaminated water into the water supply. The safety of the water supply is therefore guaranteed for everyone. The obligation to apply a break tank is usually imposed by the waterworks.
The break tank consists out of a drinking water supply and a pump. The pump ensures the required water pressure after the disconnection tank. The type of pump is dependent of the amount and types of connection points. (taps, livestock containers, sprinklers, etc.) A proper calculation by an expert is there for necessary. A pump which is too small doesn’t give enough pressure, whilst a pump which is too big leads to unnecessary energy consumption and an excessive initial investment.
The volume of the break tank is not only determined by the connection points and the pump, but mostly by the drink water supply. Which is in turn dependent on the water pressure, pipe diameter and filling tap. For that matter, it is important to calculate your system properly. GEP is happy to serve you.
GEP Breaktanks
GEP Breaktank with sumbersible pump.
GEP
GEP Break tank with diaphragm pump.
Interrupt your water supply
GEP has been trying to convince the society for over a decade regarding the necessity of decentralized water management. Nowadays we are able to offer several solutions for the development of a safe and sustainable decentralized water system. We are
specialized in the catching and cleaning of rainwater, rainwater recycling, grey water and intensive and extensive roof solutions. As a producer of system for decentralized water management, GEP is specialized in the development of pump systems and pump controls. This has
led to a wide assortment of break tanks. This wide assortment is applicable for both residential buildings and industrial buildings.
Brea
ktan
ks
B3www.breaktanks.com Breaktanks
The implementation, connections and the volume of a break tank can vary greatly per type. The most important are the legal requirements which the break tank must meet. These are enforced by the waterworks and are defined in the European technical standard EN1717.
The break tanks which are produced in accordance to the regulations and legal requirements can easily be recognized by the KIWA and Belgaqua certifications. This means that the break tanks are, in Belgium and the Netherlands, according to the regulations and are thus considered safe in all aspects.
Break tank regulations
free outlet above the drinking water tank
Type accordingto EN1717 Concept
free outlet with non-circular overflow
www.breaktanks.com BreaktanksB4 © GEP Tel. BE +32 (0)56/299.701 NL +31 (0)183 610520
GEP Breaktank Break 1The security between the drink water supply and the indoor water network is sometimes legally mandatory. The EN1717 provides a number of technical possibilities. Using water of safety class 5, such as rainwater, grey water, stagnant water, or water of unknown origin is a “free range” mandatory.
The Breaktank Break 1 by GEP is conform the EN1717 and has a type AB Break. Also, the Breaktank Break 1 is equipped with a silent prefab pump which ensures a continues water pressure for all connections. The Breaktank Break 1 is Belgaqua and KIWA certified.
Connection scheme
GEP Breaktank Break 1
• Ready to plug and play with prefab build-in pump• Continues water supply• Very compact dimensions• Stylish soundproof foam casing• Very energy efficient• Suitable for installation in kitchen cabinet• Low installation costs• Equipped with emergency overflow• Automatic operation• Water buffer 8 litres• Connection is Belgaqua and KIWA certified• Meets the strictest safety standards• Silent operation• Supplied with connection set• Suitable for ground installation• Corrosion resistant • Automatic ventilation
Product advantages:
Drinking water 3/4“
Pressure pipe 3/4“
Installation on massive floor
GEP Pressure tank
Overflow 40 mm
Brea
ktan
ks
B5www.breaktanks.com Breaktanks
Specifications
Pump characteristic Breaktank Break 1
GEP Breaktank Break 1
Height A 340 mm Volume 8 Liter
Width B 340 mm Pump type Membrane pump
Depth C 279 mm Switch-off pressure 3,0 bar
Drinking water supply D 3⁄4“ Capacity 900 L/h
Pressure pipe E 3⁄4“ Power Max. 120 W
Overflow F 40 mm Voltage 230V / 50 Hz
Weight (empty) 6 kg Switch-off pressure is adjustable. System is also available for 24 V DC
The break tanks by GEP can be applied at installations where a short disconnection of the water network is requires or is mandatory. The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.
The GEP Breaktank Break 1 is in reality used in water systems with a relatively low required flow level or where there is little free space available. Examples of these installations are in laboratories, dental practices, etc.
The Breaktank Break 1 by GEP consists out of a very small tank with a volume of 8 litres. The drinking water connection is located on the side of the unit and is conform to EN1717. This connection is Belgaqua and KIWA certified. The tank is equipped with a floater which makes sure that there is enough water in the tank. A prefab diaphragm pump is installed before the tank. This pump makes sure that the secondary water network has enough pressure. Everything is prefab installed and is removable for quick maintenance and service. The entire pump and break tank are covered by a stylish sound isolating foam cover. The system can be installed in a kitchen cabinet. The Breaktank Break 1 by GEP is delivered including the complete installation set and pressure tank.
Scope of application
GEP Breaktank Break 1
Art nr Description PG
405101 GEP Breaktank Disconnectionsystem Break 1 1
Bar
lit/min
Concept
free outlet above the drinking water tank
www.breaktanks.com BreaktanksB6 © GEP Tel. BE +32 (0)56/299.701 NL +31 (0)183 610520
GEP Breaktank Breaky 3 & 5
Connection scheme
Breaktank Breaky 3 & 5
The security between the drink water supply and the indoor water network is sometimes legally mandatory. The EN1717 provides a number of technical possibilities. Using water of safety class 5, such as rainwater, grey water, stagnant water, or water of unknown origin is a “free range” mandatory.
The Breaktank Breaky 3 & 5 by GEP are conform to EN1717 and have a type AA disconnection. These break tanks are Belgaqua and KIWA certified. The Breaktanks Breaky 3 & 5 are equipped with a prefab installed self-priming pump. The pump is a pressure control so that pressure can be guaranteed on all disconnection points.
• Very easy to control• Plug and play• Continuous water supply• Very compact dimensions• Low installation costs• Equipped with emergency overflow• Automatic operation• Water buffer: approx. 10 litres• Easy and fast to clean• Connections are Belgaqua and KIWA certified• Meets the strictest safety standards• Available with a range of pumps• Very quiet operation• Manometer with pressure display included• Pump system is including connection set• Easy to install• Pump with pressure control and run dry protection• Very reliable
Product benefits:
Pressure pipe 1”
Drinking water 3/4”
Brea
ktan
ks
B7www.breaktanks.com Breaktanks
Specifications
Pump characteristic Breaktank Breaky 3 & 5
The break tanks by GEP can be applied at installations where a short disconnection of the water network is requires or is mandatory. The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.
The GEP Breaktanks Breaky 3 & 5 are used in water systems where a normal domestic flow rate is required and where sometimes prolonged continues water usage can occur. Examples of these installations are in professional dishwashers, laboratories, small irrigation systems, slaughterhouses, etc.
The Breaktank Breaky 3 & 5 by GEP are equipped with a very small tank with a volume of 14 litres. The drinking water connection is located on the side of the unit and is conform to EN1717. This connection is Belgaqua and KIWA certified. The tank is equipped with a floater which makes sure that there is enough water in the tank. A prefab centrifugal pump is installed next to the tank, this is placed vertically which allows easy ventilation.
This pump ensures that the secundairy water network has a constant pressure by using a pressure control with dry run protection. Everything is prefab installed and removable for fast maintenance and service. The entire pump and break tank are covered with a stylish sound isolating cover. The system is suitable for wall installation. The GEP Breaktank Breaky 3 & 5 are delivered including complete connection set.
Scope of application
The GEP Breaktanks Breaky 3 & 5 is available with different prefab installed pumps in order to be able to realise different specific demands regarding pressure and capacity.
GEP Breaktank
Art nr. Description PG
405102 GEP Breaktank Disconnection system Breaky 3 1
405103 GEP Breaktank Disconnection system Breaky 5 1
RC-3 RC-5
Connection DN1 1” bi Power 900 Watt 1350 Watt
Connection DN2 3/4” bi Max. capacity 3,6 m³/h 5,4 m³/h
Length L 500 mm Max. pressure 3,5 bar 5,2 bar
Height H 730 mm Weight (empty) 28 kg
Depth D 235 mm Temperature 5-35 °C
RPM 2.900 Condensator 20 µF 25 µF
Hei
ght H
Width B
Dep
th D
Conceptrepresentation
free outlet above the drinking water tank
www.breaktanks.com BreaktanksB8 © GEP Tel. BE +32 (0)56/299.701 NL +31 (0)183 610520
GEP Breaktank Break 7The security between the drink water supply and the indoor water network is sometimes legally mandatory. The EN1717 provides a number of technical possibilities. Using water of safety class 5, such as rainwater, grey water, stagnant water, or water of unknown origin is a “free range” mandatory.
The Breaktank Break 7 by GEP is conform to EN1717 and has a type AA disconnection. This break tank is Belgaqua and KIWA certified. The Breaktanks Break 7 is equipped with a prefab installed pressure submersible pump. The pump has a pressure control so that pressure can be guaranteed on all disconnection points.
Connection scheme
Breaktank Break 7
• Very easy to control• Plug and play• Continuous water supply• Low installation costs• Equipped with emergency overflow• Automatic operation• Water buffer: approx. 570 litres• Easy and fast to clean• Connections are Belgaqua and KIWA certified• Meets the strictest safety standards• Available with a range of pumps• Very quiet operation• Manometer with pressure display included• Pump system is including connection set• Easy to install• Pump with pressure control and run dry protection
Product benefits:
Drinking water 1”
Pressure connection 1”
Brea
ktan
ks
B9www.breaktanks.com Breaktanks
Specifications
Pump characteristic Breaktank Break 7
The break tanks by GEP can be applied at installations where a short disconnection of the water network is requires or is mandatory. The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.
The GEP Breaktanks Break 7 is used in water systems where an industrial flow rate is required and where sometimes prolonged continues water usage can occur. Examples of these installations are in professional dishwashers, laboratories, medium sized irrigation systems, slaughterhouses, troughs for livestock, laundries, car washes, etc.
The Breaktank Break 7by GEP is equipped with a plastic indoor tank with a volume of 570 litres. The drinking water connection is located on the top of the unit with a type AA funnel and is conform to EN1717. This connection is Belgaqua and KIWA certified. The tank is equipped with a floater which makes sure that there is enough water in the tank. A prefab pressure submersible pump is installed in the tank. This pump keeps the secondary water network pressurized.
The Breaktank 7 is available with 3 different pressure submersible pumps which is to realise different specific demands regarding pressure and capacity. Everything is prefab installed and removable in order to realise fast maintenance and service. The breaktank is equipped with handles for an easy handling and mounting.
Scope of application
Breaktank Break 7
Height 1430 mm Protection class IP 42
Width 720 mm Voltage 230 V
Depth 720 mm Material tank PE
Drinking water connection 1“ Power pump 600 - 1.400 W
Pressure connection 1“ Volume 570 Liter
Emergency overflow DN 110 mm The break 7 is standard equipped with a 5-30 pump. The tank is equipped with a S56 cap in order to be able to empty the tank.
Weight (empty) 38 kg
Maximum capacity 5,5 m3/h
Maximum pressure 8,2 bar
The GEP Breaktanks Break 7 is available with different prefab installed pumps in order to be able to realise different specific demands regarding pressure and capacity.
1170
570 liter tank
90
135
720
1430
GEP Breaktank Break 7
Art nr. Description PG
405104 GEP Breaktank Disconnection system Break 7 1
Conceptrepresentation
free outlet with non-circular overflow
www.breaktanks.com BreaktanksB10 © GEP Tel. BE +32 (0)56/299.701 NL +31 (0)183 610520
Connection scheme
Breaktank Break 10
GEP Breaktank Break 10
Drinking water 1”
Pressure connection 6/4”
The security between the drink water supply and the indoor water network is sometimes legally mandatory. The EN1717 provides a number of technical possibilities. Using water of safety class 5, such as rainwater, grey water, stagnant water, or water of unknown origin is a “free range” mandatory.
The Breaktank Break 10 by GEP is conform to EN1717 and has a type AA disconnection. This break tank is Belgaqua and KIWA certified. The Breaktanks Break 10 is equipped with 2 prefab installed pressure submersible pumps. These pumps are equipped with a pressure control so that pressure can be guaranteed on all disconnection points.
• Very easy to control• Plug and play• Continuous water supply• Low installation costs• Equipped with emergency overflow• Automatic operation• Water buffer: approx. 570 litres• Easy and fast to clean• Connections are Belgaqua and KIWA certified• Meets the strictest safety standards• Available with a range of pumps• Very quiet operation• Manometer with pressure display included• Pump system is including connection set• Easy to install• Pump with pressure control and run dry protection• Very reliable • Cascade control of pumps • Test module per pump • Equipped with main switch
Product benefits:
Brea
ktan
ks
B11www.breaktanks.com Breaktanks
Specifications
Pump characteristic Breaktank Break 10
6-406-50 8-40
8-50
14-40
disc
harg
e he
ight
in m
Flow in l/min
Breaktank Break 10
Height 1700 mm Weight 62 kg.
Width 720 mm Volume 690 Liter
Depth 720 mm Max. pressure 4.2 - 5.8 bar
Drinking water connection
1“ Capacity 115 - 220 L/min
Pressure connection 6/4“ Power Max. 1200 - 2400 W
Emergency overflow DN 110 mm Break 10 is available with different pumps.
The break tanks by GEP can be applied at installations where a short disconnection of the water network is requires or is mandatory. The most important reason to use a disconnection tank is to prevent the contamination of the water supply by the presence of substances in the event of back-flow of the water. This includes slaughterhouses, mortuaries, dentists, irrigation, laboratories, drinking water trays livestock, car washes, laundries etc. But break tanks are also used in systems with stagnant water such as sprinkler systems, extinguishing water, etc. Even in places where they add substances to the water, such as antibiotics, one is obliged to place a disconnection tank between the drinking water supply and the indoor installation.
The GEP Breaktanks Break 10 is used in water systems where a large industrial flow rate is required and where sometimes prolonged continues water usage can occur. Examples of these installations are in professional dishwashers, large sized irrigation systems, irrigation, slaughterhouses, dairy farms, troughs for livestock, laundries, car washes, etc.
The Breaktank Break 10 by GEP is equipped with a plastic indoor tank with a volume of 570 litres. The drinking water connection is located on the top of the unit with a type AA funnel and is conform to EN1717. This connection is Belgaqua and KIWA certified. The tank is equipped with a level sensor and 2 prefab installed pressure submersible pumps. These pumps keeps the secondary water network pressurized. The pumps are cascade controlled. The Breaktank 10 is available with different pumps.
Everything is prefab installed and removable in order to realise fast maintenance and service. The breaktank is equipped with handles for an easy handling and mounting. Not only the drinking water connections, capacity and pressure is available on request, but also the tank volume. The tank volume of the Breaktank 10 is 690 litres, but also available are 750 or 1.000 litres. For special requests or specifications please contact GEP.
Scope of application
1445
690 liter tank
90
135
720
1700
Drinking water 1”
The GEP Breaktanks Break 10 is available with different prefab installed pumps in order to be able to realise different specific demands regarding pressure and capacity.
GEP Breaktank Break 10
Art nr. Description PG
405121 GEP Breaktank Disconnection system Break 10 1
Conceptrepresentation
free outlet with non-circular overflow
w w w . g e p - r a i n w a t e r . c o m
Utilize the possibilities of rainwater
GEP, the rainwater specialist!
© GEP
NL +31 (0)183 610520
BE +32 (0)56/299.701
GEP has a complete, comprehensive and quality range of products which allows composition of each project with an adequate and sustainable water system.
Rainwater
Waste Water
Disconnecting & Infiltration
Drinkingwater
DEHOUST Tanks
Breaktanks
Grey Water
Design your rainwater system onlineusing the calculation module on www.regenwater.com
GEP-Matrix® Boxes
Flatrainwater
tanks
Rainwater filters
(Rain)water pumps
IRM Rainmanagerswith integrated pump
Bladder tanks
Rainwater tanks with integrated
rainwater filter
Waste water pumpsand pump pits
top related