YOUR REF: 120227 OUR REF: DA-2013-144 3 March 2014 Stuart A Niven and Angela B Niven c/- Arenkay Designs Pty Ltd PO Box 257 DRAYTON NORTH QLD 4350 Dear Sir/Madam AMENDED PLANS ACCEPTABLE – SATISFACTORY COMPLIANCE OF CONDITION 10 Proposal: Material Change of Use - Dual Occupancy Application Number: DA-2013-144 Address: 1 Eales Road, RURAL VIEW QLD 4740 Property Description: Lot 110 on SP249177 Council acknowledges receipt of the revised plan of development for the above proposal received 28 February 2014. The approved plans are attached herein and satisfy condition 10 of the Decision Notice DA-2013-144. Please note a 3m separation distance must be accommodated between the street tree proposed for Eales Road and the driveway, or the street tree must be relocated to ensure this separation distance is provided. Street planting must be provided in accordance with Council Policy. Would you please update your records accordingly, if you require further information please email Andrea McPherson at [email protected]. Yours faithfully Shane Kleve Principal Planner This is a Mackay Regional Council digitally signed document.

Upload: others

Post on 10-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AMENDED PLANS ACCEPTABLE – SATISFACTORY COMPLIANCE … · 5000 litre rainwater tank, position tbc on site robe robe linen linen dw space wo ref space w/- wtr pantry ohc bed 1 carpet

YOUR REF: 120227 OUR REF: DA-2013-144

3 March 2014 Stuart A Niven and Angela B Niven c/- Arenkay Designs Pty Ltd PO Box 257 DRAYTON NORTH QLD 4350 Dear Sir/Madam AMENDED PLANS ACCEPTABLE – SATISFACTORY COMPLIANCE OF CONDITION 10 Proposal: Material Change of Use - Dual Occupancy Application Number: DA-2013-144 Address: 1 Eales Road, RURAL VIEW QLD 4740 Property Description: Lot 110 on SP249177

Council acknowledges receipt of the revised plan of development for the above proposal received 28 February 2014. The approved plans are attached herein and satisfy condition 10 of the Decision Notice DA-2013-144. Please note a 3m separation distance must be accommodated between the street tree proposed for Eales Road and the driveway, or the street tree must be relocated to ensure this separation distance is provided. Street planting must be provided in accordance with Council Policy. Would you please update your records accordingly, if you require further information please email Andrea McPherson at [email protected]. Yours faithfully Shane Kleve Principal Planner

This is a Mackay Regional Council digitally signed document.

Page 2: AMENDED PLANS ACCEPTABLE – SATISFACTORY COMPLIANCE … · 5000 litre rainwater tank, position tbc on site robe robe linen linen dw space wo ref space w/- wtr pantry ohc bed 1 carpet

MB

G G

mh

wm

spac

e

• lift off hinges to wc door• provide gpo & cold water provisions to dw space• sarking to external walls• continuous flow hws, position to be confirmed• mechanically vent rooms without natural ventilation• all shower roses to be AAA rated• water pressure limited to 500KPa at the meter• all ground drains to be >1000m from gas bottle

location• noggens to be positioned where indicated in

bathroom at 1100 afl for fixing of towel rail (TR)• water connection into fridge spaceADDITIONAL ITEMS OF NOTE:• 2590 ceiling height throughout• additional a/c to bed 1

Note:

A

05

48

00

Sec

tiona

l Doo

r

820

720

720

720

720

820820820

820

820

820

1800 sldrs 1800 sldrs

1800 sldrs

1800 sldrs

21

00

sld

rs

FSSF 2136

SF 2115

820

SF / FF 1818 SF / FF 1818

SF

15

18

SF 1518

SF 1515

SF 1515

SF

/ FF

180

9

SF

/ FF

180

9

SF 1212dp dp dp

dp

meterbox, positiontbc on site

fw

fw

gas bottles,position tbc on site

SF 0912recessed continuousflow hws, positiontbc on site

tap

tap

5000 litre rainwatertank, position tbc on

site

robe

robe

robe

linen

linendw space

woref spacew/- wtr

pantryohc

bed 1carpet

bed 2carpet

bed 3carpet

bed 4carpet

wircarpetmedia

carpet

ens

bath

garage

entryporch

alfresco

dining family

kit

ldry

2100 hamper overdp

dp

dp

dp

D 1

809

D 1

809

bulkhe

ad o

ver

3.3m x 1.4m slab forwater tank

1.1

m x

0.5

m s

lab

for

ac u

nit

11

70

0

39

10

35

01

38

03

50

57

10

42

60

13

80

60

60

23

03

20

07

05

30

23

01

38

02

30

56

00

23

0

23

03

80

07

01

70

07

05

60

02

30

23

03

23

07

01

00

07

01

20

07

0

23

02

03

07

02

20

07

01

20

07

0

23100

600 22050 450

230 3070 70 1800 70 1600 70 3000 70 3000 230 3880 230 4500 230

230 1900 70 1100 70 1800 70 1000 70530

70 1030 70 1900 70 3220 3900 5170 230

2210 230 1460 70

1210 6460 14980 450

480 730230 6000 230 14980

230 6000 70 3000 70 3890 70 2040 70 1200 70 4500 230

230 6000 70 1030 70 1900 70 3890 70 3310 70

70 3100 70 4100 70 4500 230

650 1800 650

18

00

99

00

18

00

53

60

30

50

14

90

23

05

57

07

03

80

02

30

24

00

23

01

27

08

00

12

00

60

07

01

50

07

06

00

93

02

30

23

01

53

07

01

50

07

03

87

02

30

23

03

80

07

05

57

02

30

23

03

20

07

053

0 70

12

00

705

30 7

053

0 70

31

00

23

0

350 wide core filledbrick piers with1/M12 rod typical

1.1

m x

0.5

m s

lab

for

ac u

nit

B

05

C

05

TR

TR

COLOUR NOTES:• Refer to colour specifications schedule for

detailed internal and externalcolours/materials

• "FWC" denotes placement of internalfeature walls (if applicable in colourspecifications)

• Refer to detail sheet for typical use offeature cabinetry and tiles

PLAN

DRAWN

DATE DRAWN

SCALE

FACADE

SHEET #COPYRIGHT PROPERTY OF SANDSKY DEVELOPMENTS PTY LTD, ALL RIGHTS RESERVED, ANY DISCREPANCY OR DEVIATION FROM THIS PLAN IS TO BE REPORTED TO SANDSKY DEVELOPMENTS PTYLTD FOR PLAN AMENDMENT. NO RESPONSIBILITY WILL BE ACCEPTED FOR UNREPORTED DEVIATIONS OR ALTERATIONS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES.

This plan certified correct is the one referred to in the inital agreement and Iunderstand changes hereafter may not be possible. These plans supercede allother previous plans or sketches.

Ph 1300 655 210PO Box 3353Helensvale TC 4212

Please Read Carefully

builders of quality new homesABN 57 082 556 194

QBSA lic no 1014147

Owner/s: .......................................................................................

Witness: ........................................................................................

Date: ..............................................................................................

FOR SANDSKY DEVELOPMENTS PTY LTDREAL PROPERTYDESCRIPTION

JOB #:

1 : 100 on A3

LOT 630 MAJOR MITCHELL DRIVE, COOMERA SPRINGS, UPPERCOOMERA

CUSTOM 228

25.01.13

SKM 03

RENDERED BRICK "URBAN"

URBAN - V2011.1

3446

Area ScheduleName Area Squares

Gross Building Arealiving areas 180.08 m² 19.38garage 37.29 m² 4.01porch 3.47 m² 0.37alfresco 9.31 m² 1.00

230.16 m² 24.77

Floor Plan

Working Drawings

Issue/Rev.

Site PlanDesign Name:

Title:

Checked By:

Drawing No: Scale:Plot Date Description Client:

3 of

Custom Dual Occupancy Dwellings

Project No:

Drawn By:

Issue:Plot Date: 19/07/2013

Designed By:Sandsky Developments

Lot 110 Hinze Circuit,Rural View QLD

13B Amendments as per mark up's26.06.13

Area Calculations

Living:

Garage:

Porch:

Alfresco:

Total:

Unit 1

Area Calculations

Living:

Garage:

Porch:

Alfresco:

Total:

Unit 2

C 19.07.13 Relocated unit 2 alfresco by 1500mm

MBOwner / s ..............................................................Date...................

Owner / s ..............................................................Date...................

Please Read CarefullyThis plan certified correct is the one referrfed to in the contract &specifications and I understand change hereafter may not bepossible. These plans supercede all other previous plans or sketches.

We reserve the right to alter designs, colours andspecifications without notice. Whilst every care hasbeen taken in the preparation of this document, theparticulars contained herein are not to be constructedas any respresentation of fact. All information provided tous is from reputable sources and no responsibility isaccepted by the vendor, it's servants or agents for any errorsor omissions. All interested parties should make their ownenquiries to satisfy themselves in relation to all matters.

© Sandsky Developments. The copyright of these floor plans are owned by Sandsky Developments. The floor plans may not be reproduced, copied or dealt with in any manner which infringes the exclusive rights of Sandsky Developments.

C

1.42 sqm

36.72 sqm

120.10 sqm

11.13 sqm

169.37 sqm

1.71 sqm

36.35 sqm

111.82 sqm

160.68 sqm

Total 330.35 sqm

10.80 sqm

m/box

HW

S

3000 ltr. slimlinewatertank to build. spec.

slab 2.8m x 1.2m

gas

bo

ttle

so

n co

nc. s

lab

1.0m

X0.

6m

HWSgas

bo

ttle

so

n co

nc. s

lab

1.0m

X0.

6m

3000

ltr.

slim

line

wat

erta

nk t

o b

uild

. sp

ec.

slab

2.8

m x

1.2

m

m/b

ox

6,000

200

4,001

4,31

4

3,50

0

3,000

4,250

4,038

5,500

3,75

0

5,00

0

3,750

4,77

4

1,228

695

550

3,20

0

6,630

1,00

0

3,000 FSL RL 20.500

FFL RL 20.635

FFL RL 20.635

FSL RL 20.465

FSL RL 20.375

FSL RL 20.410 FSL RL 20.410

FSL RL 20.375

155.42 m2

plain concretedriveway finish (3m)

exposed aggregatedriveway finish

1800 high solid screen fenceto private open space areas forwardof the building line

1800 high timber fence1800 high timber fence to front building linetapper to 1200 to boundary

refer to landscpingplan for details

refer to landscapingplan for details

rendered letterbx

telstra pits

1800 high solid screen fence return

sewer manhole

finished surface levels & gradientsshown are an approximate only

t.b.c on site

stormwater to locallegal point of discharge

stormwater to locallegal point of discharge

1800 high timber fencereturn to garage

1000mm wide landscaping strip

exposed aggregatedriveway finish continue

20.79

20.63

20.83

20.51

20.3019.83

20.06

20.44

20.52

20.33

20.35

19.93

19.59

19.42 19.04

20.66

20.70

20.63

18.78

19.65

19.63

19.66

19.94

20.0920.19

20.29

20.46

20.85

20.77

20.72

20.30

19.95

19.78

19.73

19.68

19.60

19.54

19.42

19.29

18.9118.88

18.90

18.93

18.97

18.98

19.02

19.0519.07

19.08

19.09

19.63

19.48

19.45

19.06

19.04

19.40

SL19.55

20.74

OP

OPOP

OP

OP

OP

20.71

19.92

19.90

19.88

19.8719.82

19.22

19.21

19.26

19.19

19.12

18.91

18.93 18.94

18.9418.93

18.89

19.06 19.08 19.08

19.07

19.06SL19.71

SL19.08 SL18.76

SL18.91

19.49

19.4719.37

19.33

19.26

19.20

19.15

19.12

19.15

19.23

19.31

19.41

19.89

19.77

19.71

19.4819.12

18.98

18.98

18.97

19.03

19.0

5

19.1419.25

19.42

19.39

19.17

19.10

19.07

19.04

19.01

19.05

19.0819.15

19.11

19.06

19.01

18.99

18.93

18.95

18.94

18.8118.77

18.7818.84

18.87

18.9619.3419.47

19.64

19.73

19.78

19.75

19.6919.78

19.7819.8219.85

19.58

19.5

9

19.00

19.00

19.2

5

19.25

19.2

519

.50

19.50

19.50

19.5

0

19.7

5

19.75

19.75

19.7

5

20.00

20.0

0

20.00

20.25

20.2

5

20.25

20.50

20.5

0

20.50

20.7

5

53°41‡50ˆ

20|20468°42‡

3|106

98°42‡

3|106

128°42‡3|106

143°41‡50ˆ14|19 158°41‡

6|88

188°

40‡

6|88

218°

39‡

6|92

233°41‡50ˆ

12|88

143°41‡50ˆ 33|5Conduit

Conduit

IO

Screwin Kb

Under Construction

LP

(Disclosure Plan)

109

(Vacant)

eale

s ro

ad

daw

son

Bo

ule

vard

hinze circuit

LP

Concrete Footpath

Mountable Kerb

Mo

unta

ble

Ker

b

Timber Paling Fence

No Peg

Fd

No Peg Fd

KerbOutlets

KerbOutlets

Nail in KerbRL 20.64m

TBM

Co

ncre

te F

oo

tpat

h

Co

ncre

te G

ard

en E

dg

e

No Peg Fd

Barrie

r Ker

b

Nor

th

East

Sout

h

west

gate

gate

gate

gate

E

E E

TT

T

W

W

W

Unit 2BuildingFootprint

Unit 1BuildingFootprint

r/bins

r/bins

driveway area

1:40

1:20

1:100

1:100T

E

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

SW

entry

entry

3.2m

X 1

.0m

3.2m X 1.0m

1800 high timber fencereturn to garage550mm wide landscaping strip

LOT 110825M2

FFL RL 20.635PAD RL 20.250

FFL RL 20.635PAD RL 20.250

direction of fall

SW

E

T

Stormwater

Electricity

Teltra

Legend

W Water

timber retaining wall

G Natural Gas Line

rock retaining wall

1:200 @ A3

Real Property Description

Lot Number: 110Registered Plan Number: Disclosure PlanParish: BassettCounty: CarlisleLocal Authority: Mackay R.C

Site Area: 825M2

Site Coverage: 40%

5.5 m (unit 1)0.135 m

1:40 unit 1

R.L 20.500n/aDistance

Grade 1:8Transitional

Grade

DistanceHeight GainFFLNGL (boundary)

Driveway Gradient

1:4 1:8n/a n/a

R.L 20.635

Private open space: Unit 1: 91.40m2

Unit 2: 163.20m2

Total Impermeable Area: 170.68m2 (exc. dwellings)Total Permeable Area: 333.97m2 (inc. 63.3m2 of landscaping)

• Storwater to legal point of dishcharge• Location of services and service lines shown indicative only

This is a Mackay Regional Council digitally signed document.

shane
Approved Plan-Miscellaneous