ags aerosol generation solutions for your system research ... · ags-des desiccant for ags in-line...

2
AGS Aerosol Generation System Model 9200 www.brechtel.com [email protected] Solutions for your research challenges Features: • Very constant output atomizer Controllable liquid flow rate • Atomizer sprays into a chamber to avoid backup and clogging of sprayed droplets Atomizer sample air flow rate 2-7 lpm In-line desiccant dryer to dry droplets Easy-to-change dryer desiccant with included funnel • All stainless steel construction to avoid chemical artifacts associated with plastics or glass • Automation options available to control air and liquid supply Constant and controllable aerosol generation

Upload: others

Post on 14-Jul-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AGS Aerosol Generation Solutions for your System research ... · AGS-DES Desiccant for AGS in-line dryer (10 lbs non-indicating and ½ lb indicating) ... K. Chan (2014), Performance

AGS Aerosol Generation SystemModel 9200

[email protected]

Solutions for your research challenges

Features:• Very constant output atomizer • Controllable liquid flow rate• Atomizer sprays into a chamber to avoid backup and clogging of

sprayed droplets• Atomizer sample air flow rate 2-7 lpm • In-line desiccant dryer to dry droplets• Easy-to-change dryer desiccant with included funnel • All stainless steel construction to avoid chemical artifacts associated

with plastics or glass • Automation options available to control air and liquid supply

Constant and controllable aerosol generation

Page 2: AGS Aerosol Generation Solutions for your System research ... · AGS-DES Desiccant for AGS in-line dryer (10 lbs non-indicating and ½ lb indicating) ... K. Chan (2014), Performance

1789 Addison Way • Hayward, CA 94544 • 510-732-9723 • [email protected]

In-Line Dryer

To OrderPart No. Description

9200 Aerosol Generation System (AGS)

9202 Automated Aerosol Generation System, includes Model 9200 AGS plus Auto-3way valve chassis

AGS-DES Desiccant for AGS in-line dryer (10 lbs non-indicating and ½ lb indicating)

AGS-FUN Filling funnel for AGS in-line dryer

AGS-3Way Automated 3-way valve & electronics in rack-mountable chassis

AGS-BOT Liquid supply bottle for AGS, 1000 ml

AGS-DB Drain Bottle for AGS Atomizer Chamber

AGS-P115 External compressor, 115 V, with regulator and HEPA filter

AGS-P230 External compressor, 230 V, with regulator and HEPA filter

AGS-Kit Maintenance Kit for 9200 and 9202 AGS

SpecificationsParameter Value

Air flow rate inside atomizer chamber 2 to 7 lpm

Atomizer liquid flow rate 0.1 to 6 ml/hr

Droplet diameter at 30 psig 1.0 micron

Droplet diameter at 50 psig 0.8 micron

Mode particle diameter at 30 psig (0.025% NaCI) 50 nm

Mode particle diameter at 50 psig (0.025% NaCI) 45 nm

Typical output concentrations 1,000 to 200,000 cm-3

Atomizer chamber size 4”dia. x 5” length/10.2 x 12.7 cm

In-line dryer size (x2 cylinders) 2.5” dia. x 18” length/6.4 x 45.7 cm

In-line dryer desiccant capacity 0.75 gallon/2.84 lt

Atomizer bottle capacity 1,000 ml

Dimensions 19 x 26 x 8 in/48.3 x 66 x 20.3 cm

Total system weight 20 lbs/9 kg

Operating temperature range 15-45° C

Operating pressure range 0.7 to 1 atm

Construction Stainless steel

Providing Aerosol Measurement Solutions

Copyright ©2017 All specifications are subject to change without notice. BMI assumes no responsibility for inaccuracies in this document or for any obligation to update information in this document. BMI reserves the right to change, modify, transfer or otherwise revise this publication without prior notice.

*Some products may be shown with optional accessories, which are sold separately. Items shown may not be to scale.

Publication:Xerxes F. Lopez-Yglesias, Ming Chee Yeung, Stephen E. Dey, Fred J. Brechtel and Chak K. Chan (2014), Performance evaluation of the Brechtel Mfg. Humidified Tandem Differential Mobility Analyzer (BMI HTDMA) for studying hygroscopic properties of aerosol particles, Aerosol Science and Technology, July 2014; DOI:10.1080/02786826.2014.952366

Atomizer Chamber

Applications• Seed aerosol generation for smog chambers• Laboratory flow-tube reactor studies• Cloud condensation nucleus instrument calibrations• HTDMA, OPC, Scanning DMA and other instrument

calibrations• Aerosol health impact studies

How to Order