AFM at Video Rate and Beyond
Frontiers in Scanning Probe Microscopy,Purdue University, October 2006
Mervyn Miles
H.H. Wills Physics LaboratoryIRC in Nanotechnology
University of BristolTyndall Avenue
BristolU.K.
IRC inNanotechnology
![Page 2: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/2.jpg)
High-resolution 3-D imaging;
Imaging in liquid, air, & vacuum;
No staining or coating required;
No radiation damage;
Mapping of physical properties;
Modification of surfaces;
Non-scanning applications: force spectroscopy, sensors, ...
Atomic Force Microscopy: Strengths
![Page 3: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/3.jpg)
Speed Weakness of SPM
Imaging rate too low:
to follow many processes;
to examine large areas of a specimen;
to create or manipulate structures over usefully large areas.
![Page 4: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/4.jpg)
Scanning system ~ inertia and resonance problems
Feedback loop response time
Response of interaction sensor
Force-sensing cantilever has inertia and resonance
L i m i t a t i o n s o f C o n v e n t i o n a l S P M
General to all SPMs
S p e c i f i c t o A F M
![Page 5: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/5.jpg)
Parallel imaging with multiple cantilevers
Strobe imaging of repetitive processes
Decrease Q in AC modes
Shift the time domain using higher frequencies
Another method ....
How to go faster:
![Page 6: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/6.jpg)
S o l u t i o n 1
Decrease the mass of the scanning system
Increase the stiffness of the scanning system
Decrease the mass of the cantilever
Increase the stiffness of the cantilever
Decrease the Q factor of the cantilever
![Page 7: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/7.jpg)
Instead of avoiding resonance,
use a resonating beam
for scanning in the fast direction
A Different Solution
![Page 8: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/8.jpg)
S o l u t i o n 2
Scan by oscillating at resonance with a high amplitude - resonant scanning microscopy (RSM);
High Q-factor results in high scan stability;
Data are collected throughout each sweep;
![Page 9: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/9.jpg)
Before high-speed AFM,
we first built a high-speed SNOM
![Page 10: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/10.jpg)
Specimen
scan
OpticalDetector Optical fibreQuartz Tuning Fork
(Drive & feedback)
Capture & ProcessingElectronics
Feedback Control
Scanning Near-field Optical Microscopy (SNOM)
Exponential decay of evanescent field away
from the interface
ADL Humphris, JK Hobbs, MJ Miles, Applied Physics Letters, 83(1), 6-8 (2003)
![Page 11: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/11.jpg)
Melt-tapered optical fibre SNOM probe
![Page 12: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/12.jpg)
Specimen
scan
OpticalDetector Optical fibreQuartz Tuning Fork
(Drive & feedback)
Capture & ProcessingElectronics
Feedback Control
Scanning Near-field Optical Microscopy (SNOM)
Exponential decay of evanescent field away
from the interface
ADL Humphris, JK Hobbs, MJ Miles, Applied Physics Letters, 83(1), 6-8 (2003)
![Page 13: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/13.jpg)
LaserDetector
Probe
Transverse dynamic force microscope (TDFM)
IRC inNanotechnology
![Page 14: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/14.jpg)
Low-amplitude (~1 nm) Oscillations
![Page 15: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/15.jpg)
Transverse Dynamic Force Microscope, TDFM
M Antognozzi
![Page 16: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/16.jpg)
-1 -0.5 0 0.5 1 1.5 2 2.5 3 3.5 4tip-sample distance (nm)
0
0.2
0.4
0.6
0.8
a bPROBE PROBE
SAMPLE SAMPLE
Surface detection via confined water layer
M Antognozzi, ADL Humphris, MJ Miles, APPLIED PHYSICS LETTERS, 78(3), 300-302 (2001)
![Page 17: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/17.jpg)
Low-amplitude (~1 nm) Oscillations
![Page 18: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/18.jpg)
High-amplitude (~ 5 µm) for fast axis scanning
Tip scanning in fixed plane set by average optical intensity
For high-speed SNOM
ADL Humphris, JK Hobbs, MJ Miles, Applied Physics Letters, 83(1), 6-8 (2003)
![Page 19: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/19.jpg)
Several crystals may nucleate together and grow to forma spherical structure known as a spherulite.
�
Spherulite
Within the spherulite, the polymer crystals grow radially from the centre in a ribbon morphology
These ribbon crystals often twist as they grow with the same pitch and remain in phase.
In a thin film, the spherulite is a disk-like structure in which the coherent twisting of the ribbon crystals results in concentric rings
with the ribbons alternately flat on and edge.
![Page 20: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/20.jpg)
5 µm5 µm
Crystallization of poly(hydroxybutyrate-co-valerate) (PHB/V)
Quality factor has been reduced from 270 to 90. Tip velocity was 403µm/s, line rate 8Hz
AFM
Topography Phase
![Page 21: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/21.jpg)
High Amplitude Oscillations
![Page 22: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/22.jpg)
Birefringent PSTM
Shear-force controlledvia tuning fork
2 µm Height
2 µm Optical
P
A
Slow scanning - 20 minutes/imageassisted with active Q
Detector
Polariser
Analyser
ADL Humphris/JK Hobbssee, e.g., RL Williamson, MJ Miles, JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 14(2), 809-811 (1996
![Page 23: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/23.jpg)
High Amplitude Oscillations
![Page 24: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/24.jpg)
Conventional SNOM1 frame in 1000 sec
RSM SNOM120 frames/sec
PHB spherulite between crossed polars
Comparison:Conventional SNOM & RSM SNOM
200 nm
> 100,000 Faster than existing SNOM
ADL Humphris, JK Hobbs, MJ Miles, Applied Physics Letters, 83(1), 6-8 (2003)
![Page 25: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/25.jpg)
High-speed SNOM of collagen
Intensity related to height - 67 nm repeat of collagen visible
A Major (Uni Wien, ), L Bozec, MA Horton, Miles
![Page 26: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/26.jpg)
Specimen
scan
OpticalDetector
Optical fibre
Quartz Tuning Fork(Drive & feedback)
Capture & ProcessingElectronics
Feedback Control
Scanning Near-field Optical Microscopy (SNOM)
transmission
Analyzer
Polarizer
A. Ulcinas, M Antognozzi
![Page 27: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/27.jpg)
piezo drivers operating in tandem
` flexures
sample stage
Flexure Stage for high-speed SPM
This flexure stage provides the high-speed scan of up to 40kHz with about 3 µm amplitude
Picco, Engledew
![Page 28: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/28.jpg)
High-speed SNOM of polymer spherulite of PHB
Flexure stage scanner - 3 µm x 3 µm imageTransmission SNOM with crossed polars
A. Ulcinas, M Antognozzi, Picco, Engledew
![Page 29: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/29.jpg)
High-speed AFM
![Page 30: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/30.jpg)
Resonant scanning AFM
conventional scan tube
cantilever
piezo stack (y)
QCR (x)
top
side Resonant sample scan stage (x)
Piezo stack for ‘slow’ scan (y)
No electronic feedback
Mechanical feedback
super lubricity
water in confined geometry
ADL Humphris, MJ Miles, JK Hobbs, Applied Physics Letters, 86(3), Art.No. 034106 (2005)
![Page 31: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/31.jpg)
High-speed AFM of Chitosan Film
30 frames/s(Infinitesima vAFM)
Ulcinas, Payne, Heppenstall-Butler1µm x 1µm
Conventional AFM
> 3000 Faster than conventional AFM
- tuning-fork resonance scanning
![Page 32: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/32.jpg)
piezo drivers operating in tandem
` flexures
sample stage
Flexure Stage for high-speed SPM
This flexure stage provides the high-speed scan of up to 40kHz with about 3 µm amplitude
Picco, Engledew
![Page 33: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/33.jpg)
PEO Spherulite video AFM
30 frames/second1.5 µm x 1.5 µm
Engledew, Picco, Miles
- flexure stage (non-resonance) scanning
![Page 34: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/34.jpg)
Engledew, Picco, Miles
PEO Spherulite video AFM
30 frames/second
- flexure stage (non-resonance) scanning
![Page 35: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/35.jpg)
30 frames/second1.5 µm x 1.5 µm Engledew, Picco, Miles
PEO Spherulite video AFM
![Page 36: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/36.jpg)
0 mins0 frames
10 mins18,000 frames
3 mins~ 6000 frames
7 mins13,000 frames
PEO video AFM 30 f/s - image reproducibility
![Page 37: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/37.jpg)
High-speed AFM of ‘large’ objects
![Page 38: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/38.jpg)
Air c AFM
Picco, Miles, Komatsubara, Hoshi, Ushiki
Set of human chromosomes
![Page 39: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/39.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
Human Chromosome No. 2
![Page 40: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/40.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
![Page 41: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/41.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
Air
High-speed AFM of parts of human chromosomes
Picco, Miles, Komatsubara, Hoshi, Ushiki
![Page 42: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/42.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
Montage of high-speed AFM images of part of human chromosome No. 2
![Page 43: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/43.jpg)
![Page 44: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/44.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
Air
![Page 45: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/45.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
2M NaCl
![Page 46: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/46.jpg)
Picco, Miles, Komatsubara, Hoshi, Ushiki
2M NaCl
Human chromosomes in liquid
Height range: ~0.5 µm
![Page 47: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/47.jpg)
Conventional AFM Image of Collagen Specimen
![Page 48: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/48.jpg)
Collagen Fibres
Banding periodicity: 67 nm
30 fps Picco, Bozec, Horton Engledew
![Page 49: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/49.jpg)
Conventional AFM
High-speed AFM
All the high-speed images were taken in 0.7 s
Linear Collage of High-speed AFM Images of Collagen Fibre
![Page 50: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/50.jpg)
Single frame from collagen movie
Image acquired in 17 msPicco, Bozec, Horton Engledew
![Page 51: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/51.jpg)
High-speed AFM Collagen Collage
12 images involved - acquired in 200 msPicco, Bozec, Horton Engledew, Miles
![Page 52: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/52.jpg)
Large area collagen collage
103 images acquired in 1.7 s
![Page 53: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/53.jpg)
Non-imaging:
High-speed writing
Electrochemical oxidation of passived silicon
![Page 54: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/54.jpg)
Local AFM electrochemical oxidation
Can be used to pattern surface -conventional AFM too slow to pattern large areas
![Page 55: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/55.jpg)
250 nm
10 ms; -12 V Si tip; conventional AFM
non-contact
Ti Oxidation James Vicary
![Page 56: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/56.jpg)
Topographic AFM images of oxide nanostructures created with a -12 V tip bias for pulse times. Height range: 2 nm.
100 µs
50 µs
10 µs
5 µs
1 µs
500 ns
Oxidation of Silicon with high-speed AFM
Picco, Vicary
![Page 57: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/57.jpg)
High-speed AFM
Simultaneous writing (oxidation) and imaging
3 voltage pulses synchronized to fast line scan
30 fps
Read-Write
Picco, Vicary
![Page 58: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/58.jpg)
Conventional AFM of oxidized lines on Si
![Page 59: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/59.jpg)
How fast can this system image?
9 fps 15 fps 30 fps
High-speed AFM of Collagen
30 fps50751002505007501000>1000
AFM images in less than 1 ms
Bimorph Tuning fork Flexure
![Page 60: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/60.jpg)
`
piezo drivers operating in tandem
tuning fork scanning
Scanner Arrangement for kilohertz AFM
![Page 61: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/61.jpg)
500 nm x 500 nm
Collagen
Playback slowed down by > 40 times!
Frame Rate:
1300 fps
Line Rate:
64,000 lps
Each frame acquired in: 750 µs
PlaybackRate:25 fps
Collagen banding 67 nm
1 Million Images generated in ~15 minutes!Picco, Ulcinas, Antognozzi, Engledew, Horton, Bozec, Miles
![Page 62: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/62.jpg)
CollagenFrame Rate:
1200 fps
Line Rate:
64,000 lps
Specimen being oscillate by 50 nm
500 nm x 500 nm
PlaybackRate:25 fps
Collagen banding = 67 nm
Picco, Ulcinas, Antognozzi, Engledew, Horton, Bozec, Miles
![Page 63: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/63.jpg)
Composite image from 1000 fps AFM of Collagen
200 nm
![Page 64: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/64.jpg)
So far, the movies were rather pixellated ....
... this can be fixed by increasing the line rate further ....
![Page 65: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/65.jpg)
Picco, Ulcinas, Antognozzi, Engledew, Horton, Bozec, Miles
Frame Rate:1000 fps
Line Rate:
200,000 lps
PlaybackRate:25 fps
200 x 100 pixels; ~ 25 ns/pixel (on average)
![Page 66: AFM at video rate and beyond](https://reader034.vdocuments.mx/reader034/viewer/2022051819/551f36854a7959a5108b4d10/html5/thumbnails/66.jpg)
Nanoscience and QI Centre, Bristol
Thanks to...
i
Peter Dunton Massimo AntognozziMonica BerryDebra BrayshawDavid EngledewSimon HawardJon Hayes(Jamie Hobbs)(Andy Humphris*)Terry McMaster
(Andras Major)Sheila MorrisLoren PiccoAndy Round Mark SzczelkunArturas UlcinasJames VicaryCraig WilliamsAlex Wotherspoon
Infinitesima
Niigata University:Tatsuo UshikiOsamu HoshiNae Komatsubara
UCL, London :Michael HortonLaurent Bozec
*www.infinitesima.com Thank you for your attention