advanced biomedical waste treatment solutions · advanced biomedical waste treatment solutions ......
TRANSCRIPT
A DVA NCED BIOMEDICA L WA S T E T RE AT MEN T S OL U T IONS
Gra
phic
des
ign:
ww
w.im
age-
et-c
omm
unic
atio
n.co
m -
Ref
. T00
-005
-EN
– Im
p. 1
1/20
14
Tesalys, is the story of two people who met a long time ago
in a small office in the center of the French city of Toulouse.
At that time Patrick Hengl had developed one of the first
machines to process infectious waste by disinfection, and
Miquel Lozano worked for a sterilizer manufacturer. 20 years
later, they have brought together their worldwide experience
in biohazard waste processing, disinfection and sterilization
within Tesalys, your biomedical waste processing partner.
ADVANCED BIOMEDICAL WASTE TREATMENT SOLUTIONS The disposal of biohazard waste is not easy. It implies risks for the environment and the personnel not to mention high collection, transport and incineration costs; the producer is responsible for the waste until it has been completely destroyed. Disposal must also comply with local procedures and regulations.
At Tesalys, we know how to handle all this, and we provide you with advanced solutions to make biomedical waste safe, which mod-ifies its appearance and reduces risks, volume, and disposal costs.
Our solutions are suitable for:
• Hospitals, clinics and outpatient surgical centers
• Ambulatory care centers, dispensaries
• Dental offices, Medical centers
• Homecare centers
• Dialysis & transfusion centers, blood banks
• Clinical laboratories
• Life Science Research & Public Health laboratories
• Pharmaceutical R&D labs
• Biotech & Vaccine production facilities
• Animal Care & Research facilities
• Biocontainment facilities
• Agricultural & food laboratories
• Public facilities, transportation care centers
• Civil & Military ships and aircrafts
• Prisons & detention centers
• Waste management service providers
STERIPLUS™
Tesalys STERIPLUSTM systems are the ideal solution to treat biocontaminated waste. The unique TESASHREDTM shredding built-in system reduces significantly waste volume and weight and guarantees thermal treatment at the center of the waste. Autoclaving/sterilization process at 135°C grants up to 8 log
10 microbial reduction. Our systems address the needs of healthcare centers, laboratories and all other locations where biomedical waste is produced. They can process waste bags, cardboard or rigid containers containing all kinds of surgical, medical and research and healthcare waste, like sharps, gloves, labware, glass, plastic/rubber tubing, filters. They can also manage a large volume of liquid waste. Tesalys STERIPLUSTM systems have been designed to be installed as close as possible to the waste generation point. Several units can be juxtaposed in order to obtain a quicker flow.
Tesalys ADVISORY SERVICESBecause our staff is highly experienced in biomedical waste processing, we also provide the following advisory services :
• Design of customized waste treatment equipment for specific applications.• Audit of your biohazard waste disposal strategy, procedures and solutions.• Architectural support, facility workflow and capacity planning.• Economic evaluations.• Education and training of your staff on waste treatment.
The Safest Shredding & Autoclaving System for Biomedical Waste
by
YOUR INFECTIOUS WASTE DECONTAMINATED AND SHREDDED IN 30 MIN
AS SIMPLE AS 1, 2, 3…
Safe loading of waste
Step 1 Shredding (8-10 mm).
Step 2 Decontamination process at 135°C for 10 min.(steam sterilization)
Step 3 Evacuation of biodecontaminated effluentsto sewer.
Unloading of biodecontaminated solid waste for disposal via household waste circuit*
STERIPLUS™
*Disposal circuit varies according to country/local regulations.
DECONTAMINATION: PROVEN 8 log10 REDUCTION OF
BACTERIAL SPORES
8 log10 REDUCTIONVALIDATED PROCESS BY STEAM
STERILIZATION AT 135°C
TESASHREDTM SHREDDER:TRANSFORM WASTEINTO UNRECOGNIZABLE8-10 MM. PIECES
SHREDDER FEEDING SYSTEM: TOTALLY SEALED AND AUTOMATIC, WITH WASTE LEVEL DETECTION
WASTE INTRODUCTION CHAMBER: AUTOMATIC STEAM DECONTAMINATION BETWEEN CYCLES
SOLID WASTE REDUCTION BY UP TO 80% IN VOLUME, BY UP TO 50% IN WEIGHT
LIQUID WASTE/EFFLUENTS DECONTAMINATED BEFORE DISPOSAL TO SEWER
EXHAUST AIR FILTRATION BY 0,2μm FILTER
WATER SOFTENER & BOOSTER PUMP,
AIR COMPRESSORINCLUDED
FULL CYCLE TRACEABILITYVIA PRINTER
TECHNICAL DATA
CAPACITY 20l / cycle, representing 2-2.5kg per cycle* 40l / cycle, representing 4-5kg per cycle*
USEFUL LOADING CHAMBER DIMENSIONS
320 x 247mm (w x d),useful height = 270mm
320 x 247mm (w x d), useful height = 480mm
TOTAL CYCLE TIME 30-35min 30-35min
PRODUCTION Up to 5kg/h* up to 10kg/h*
EXTERNAL DIMENSIONS (H X W X D)
1 150mm x 1 205mm x 885mm(h x w x d)
1405mm x 1 205mm x 885mm(h x w x d)
NET WEIGHT 490kg 560kg
PROCESS CHAMBER Stainless steel AISI 304L
STEAM GENERATORStainless steel AISI 304L (chamber) highly corrosion-resistant Hastelloy® (heating element)
WATER SOFTENER Option (external) Supplied with the equipment
WATER BOOSTER PUMP, AIR COMPRESSOR
Supplied with the equipment
SHREDDER Stainless steel AISI 304L (structure) hard steel (cutting blades)
PIPING Stainless steel / PTFE flexible hosing
FRAME Painted steel
BODYWORK Composite material / painted steel
UTILITY REQUIREMENTS
WATER RequirementsSoftened water 4-8°TH
Potable quality water (water softener and booster pump included)
Consumptions 5 to 6 liters ≈ 10 liters
ELECTRICITY Requirements 400V III N, 50Hz, 10kW 400V III N, 50Hz, 15kW
Consumptions 2 kW/h 4 to 5 kW/h
DRAIN Sewer hose inner ø 32mm
STEAM / COMPRESSED AIRBuilt-in steam generator and air compressor. No need for external supply of steam / compressed air.
OPTIONS & ACCESSORIES• Start-up kit.
• Maintenance parts kit for 2 years.
• Waste unloading system STERIPLUSTM System.
• Voltage/frequency adaptations.
• Special packaging.
Gra
phic
des
ign:
ww
w.im
age-
et-c
omm
unic
atio
n.co
m -
Ref
. T00
-005
-EN
– Im
p. 1
1/20
14
PRODUCT SPECIFICATIONS
STERIPLUSTM 20 model is a marketing variant of the AB MED 20 model.STERIPLUSTM and TESASHREDTM are Tesalys registered trademarks
*For a density of 0.1/0.12 kg/l
Distributed by:
CO
MPLIANT
STANDARD
NFX 30-503
ENVIRONMENTAL FEATURES• Reduction of “waste footprint”: Solid waste
reduced by up to 80% in volume, by up to
50% in weight.
• “Clean” effluents: thermal decontamination
prior to discharge.
• “Clean” air: exhaust air filtration by
0,2μm microbial filter.
• Very low water and energy consumptions.
• Energy savings: built-in heat recovery system.
• No chemicals used, just water.
STERIPLUS™ 20 STERIPLUS™ 40
Designed and manufactured in Franceaccording to NF X30-503
marked (european directive 2006/42/CEE, harmonized standards machinery safety)Qualification of sterilization cycle accordingto international standards EN 554 and EN ISO 17665-1